🇵🇱 MIEJSKI ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL
Water & wastewaterEnvironment
MIEJSKI ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1097 (Kęty, Poland). Its accreditation scope covers 39 test methods in the following areas: Water & wastewater, Environment. Test objects include: Water, Wastewater, Sewage sludge, Waste O): code 19 08 05, Wastewater. Most frequently used techniques: Spectrophotometric method, Gravimetric method, Titrimetric method.
At a glance
- Accreditation number: PCA AB 1097
- Methods in scope: 39
- Types of test objects: 10
- Techniques used: 7
- City: Kęty, Poland
- Accreditation number
- AB 1097
- Accreditation body
- PCA
- Address
- ul. Św. M. Kolbe 25a, 32-650 Kęty, LABORATORIUM, ul. Słowackiego 37, 32-650 Kęty
- City
- Kęty, Poland
What this laboratory tests (10)
- Water, Wastewater — 13 methods
- Sewage sludge — 7 methods
- Waste O): code 19 08 05 — 7 methods
- Wastewater — 5 methods
- Water — 2 methods
- Agriculturally used soil — 1 method
- Mineral soil — 1 method
- Rainwater, snowmelt water — 1 method
- Soil — 1 method
- Woda, Ścieki, Wody opadowe, wody roztopowe — 1 method
Analytical techniques used (7)
- Spectrophotometric method — 10 methods
- Gravimetric method — 7 methods
- Titrimetric method — 7 methods
- Potentiometric method — 4 methods
- Electrochemical method — 2 methods
- Manual and automatic method — 1 method
- Manual method — 1 method
Laboratory locations
- Laboratorium — ul. Słowackiego 37
Accreditation scope — test methods (39)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory | |||||
| 1 | Water | Sampling for chemical and physical testing | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6, 8.2 | ||
| 2 | Water | Temperature Range (1,0 – 30,0) °C |
PN-77/C-04584 | ||
| 3 | Rainwater, snowmelt water | Sampling for chemical and physical testing | Manual method | PN-ISO 5667-10:2021-11 | |
| 4 | Wastewater | Sampling for chemical and physical testing | Manual and automatic method | PN-ISO 5667-10:2021-11 | |
| 5 | Wastewater | Temperature Range (1,0 – 50,0) °C |
PN-77/C-04584 | ||
| 6 | Wastewater | Ammonium nitrogen concentration Range (0,30 – 1000) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 7 | Wastewater | Concentration of anionic surfactants (anionic surface-active substances) Range (0,060 – 98) mg/l |
Spectrophotometric method | PN-EN 903:2002 | |
| 8 | Wastewater | Substances extractable with petroleum ether Range (5,0 – 1000) mg/l |
Gravimetric method | PB/22 wydanie 1 z dnia 16.08.2011 r. | |
| 9 | Woda, Ścieki, Wody opadowe, wody roztopowe | Total suspended solids (TSS) Range (2,0 – 10000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 10 | Water, Wastewater | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 11 | Water, Wastewater | Biochemical oxygen demand - BOD5 Range (0,5 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 12 | Water, Wastewater | Biochemical oxygen demand - BOD5 Range (6 – 5000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 13 | Water, Wastewater | Chemical oxygen demand – COD-Cr Range (6,00 – 20000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 14 | Water, Wastewater | Chloride concentration Range (5,00 – 2000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 15 | Water, Wastewater | Sulfate concentration Range (10,0 – 1000) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 16 | Water, Wastewater | Total phosphorus concentration Range (0,070 – 100) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010 | |
| 17 | Water, Wastewater | Phenol index Range (0,002 – 2,6) mg/l |
Spectrophotometric method | PN-ISO 6439:1994 Metoda B | |
| 18 | Water, Wastewater | Nitrate nitrogen concentration Range (0,040 – 50,0) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 19 | Water, Wastewater | Nitrite nitrogen concentration Range (0,003 – 20,0) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 20 | Water, Wastewater | Ammonium nitrogen concentration Range (0,016 – 15,0) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 21 | Water, Wastewater | Kjeldahl nitrogen concentration Range (0,40 – 1000) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 22 | Water, Wastewater | Total nitrogen concentration (calculated) | PB/21 wydanie 2 z dnia 03.07.2009 r. | ||
| 23 | Agriculturally used soil | Sampling for chemical and physical testing | PN-ISO 10381-4:2007 z wył. pkt. 8 | ||
| 24 | Soil | pH – in H2O Range 4,0 – 13,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 25 | Mineral soil | Available phosphorus content Range (2,0 – 40,0) mg/100 g P2O5 |
Spectrophotometric method | PN-R-04023:1996 | |
| 26 | Sewage sludge | Sampling for chemical and physical testing | PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.10 | ||
| 27 | Sewage sludge | pH – in H2O Range 4,0 – 13,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 28 | Sewage sludge | Loss on ignition of dry matter (LOI) Range (5,0 – 95,0) % |
Gravimetric method | PN-EN 15935:2022-01 z wyłączeniem pkt. 7.4, 8.2 | |
| 29 | Sewage sludge | Total phosphorus content Range (0,050 – 5,0) % s.m. |
Spectrophotometric method | PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 | |
| 30 | Sewage sludge | Total Kjeldahl nitrogen content Range (0,40 – 10) % s.m. |
Titrimetric method | PN-EN 13342:2002 | |
| 31 | Sewage sludge | Ammonium nitrogen content Range (0,10 – 5,0) % s.m. |
Titrimetric method | PN-EN 14671:2007 | PN-ISO 5664:2002 | |
| 32 | Sewage sludge | Dry residue Range (0,50 – 93,0) % |
Gravimetric method | PN-EN 15934:2013-02 Metoda A | |
| 33 | Waste O): code 19 08 05 | Sampling for chemical and physical testing Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.10 | ||
| 34 | Waste O): code 19 08 05 | pH – in H2O Range 4,0 – 13,0 Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 35 | Waste O): code 19 08 05 | Loss on ignition of dry matter (LOI) Range (5,0 – 95,0) % Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Gravimetric method | PN-EN 15935:2022-01 z wyłączeniem pkt. 7.4, 8.2 | |
| 36 | Waste O): code 19 08 05 | Total phosphorus content Range (0,050 – 5,0) % s.m. Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Spectrophotometric method | PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 | |
| 37 | Waste O): code 19 08 05 | Total Kjeldahl nitrogen content Range (0,40 – 10) % s.m. Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Titrimetric method | PN-EN 13342:2002 | |
| 38 | Waste O): code 19 08 05 | Ammonium nitrogen content Range (0,10 – 5,0) % s.m. Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Titrimetric method | PN-EN 14671:2007 | PN-ISO 5664:2002 | |
| 39 | Waste O): code 19 08 05 | Dry residue Range (0,50 – 93,0) % Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23). O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Gravimetric method | PN-EN 15934:2013-02 Metoda A | |
Reference standards (30)
PB/21 wydanie 2 z dnia 03.07.2009 r.
PB/22 wydanie 1 z dnia 16.08.2011 r.
PN-77/C-04584
PN-82/C-04576.08
PN-EN 13342:2002
PN-EN 14671:2007
PN-EN 14672:2006
PN-EN 15934:2013-02 Metoda A
PN-EN 15935:2022-01 z wyłączeniem pkt. 7.4, 8.2
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.10
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6, 8.2
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010
PN-ISO 10381-4:2007 z wył. pkt. 8
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 6439:1994 Metoda B
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-R-04023:1996