🇵🇱 HYDROACUSTIC Piotr Hilszer PL

PCA AB 1082 • Murowana Goślina, Poland • 9 methods

Environment

HYDROACUSTIC Piotr Hilszer is a laboratory accredited by PCA under number AB 1082 (Murowana Goślina, Poland). Its accreditation scope covers 9 test methods in the following areas: Environment. Test objects include: General environment - noise from roads, railway lines and tram lines, General environment - noise barriers „in situ”, General environment - noise from installations, equipment and indus…, Workplace environment − noise. Most frequently used techniques: Direct measurement method.

At a glance

  • Accreditation number: PCA AB 1082
  • Methods in scope: 9
  • Types of test objects: 4
  • Techniques used: 1
  • City: Murowana Goślina, Poland
Accreditation number
AB 1082
Accreditation body
PCA
Address
ul. Gnieźnieńska 34, 62-095 Murowana Goślina
City
Murowana Goślina, Poland

What this laboratory tests (4)

Analytical techniques used (1)

Accreditation scope — test methods (9)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 General environment - noise from roads, railway lines and tram lines A-weighted equivalent sound pressure level Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140. poz. 824, i Nr 288 poz. 1697) z wyłączeniem punktu H
2 General environment - noise from roads, railway lines and tram lines A-weighted sound exposure level
Range (24 – 100) dB
Direct measurement method Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140. poz. 824, i Nr 288 poz. 1697) z wyłączeniem punktu H
3 General environment - noise from roads, railway lines and tram lines A-weighted equivalent sound level over the reference time T expressed by the indicators LAeq, D, LAeq, N (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140. poz. 824, i Nr 288 poz. 1697) z wyłączeniem punktu H
4 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (24 – 100) dB
Direct measurement method Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F
5 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound level over the reference time T expressed by the indicators LAeq, D, LAeq, N (calculated) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F
6 General environment - noise barriers „in situ” A-weighted equivalent sound pressure level
Range (24 - 100) dB
Direct measurement method PN-ISO 10847:2002
7 General environment - noise barriers „in situ” Efficiency of the screen (calculated) PN-ISO 10847:2002
8 Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level C-weighted peak sound level
Range (55 - 135) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 - punkt 11
9 Workplace environment − noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 - punkt 11

Reference standards (5)

PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 - punkt 11
PN-ISO 10847:2002
PN-N-01307:1994
Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F
Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140. poz. 824, i Nr 288 poz. 1697) z wyłączeniem punktu H