🇵🇱 PAKO-LAB PL

PCA AB 1080 • Kielce, Poland • 7 methods

Environment

PAKO-LAB is a laboratory accredited by PCA under number AB 1080 (Kielce, Poland). Its accreditation scope covers 7 test methods in the following areas: Environment. Test objects include: Workplace environment − air, Workplace environment − hot microclimate, Workplace environment − noise. Most frequently used techniques: Direct measurement method, Gravimetric method, Personal dosimetry method.

At a glance

  • Accreditation number: PCA AB 1080
  • Methods in scope: 7
  • Types of test objects: 3
  • Techniques used: 3
  • City: Kielce, Poland
Accreditation number
AB 1080
Accreditation body
PCA
Address
MAGDALENA PAWEŁKIEWICZ, ul. Jagiellońska 109, 25-734 Kielce
City
Kielce, Poland

What this laboratory tests (3)

Analytical techniques used (3)

Accreditation scope — test methods (7)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment − air Sampling for the assessment of occupational exposure to:
dust agents − inhalable fraction − respirable fraction organic substances inorganic substances − respirable fraction
Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
2 Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
3 Workplace environment − air Concentration of harmful dust agents - inhalable fraction:
Natural graphite Synthetic graphite Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,12 – 17,0) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
4 Workplace environment − air Concentration of harmful dust agents - respirable fraction:
Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range (0,1 – 7,8) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
5 Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (28 – 135) dB C-weighted peak sound pressure level Range (69 – 140) dB Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated)
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 3 - p.11
6 Workplace environment − hot microclimate Air temperature
Range (20 - 50) °C Natural wet bulb temperature Range (10 - 40) °C Black globe temperature Range (20 - 50) °C
Direct measurement method PN-EN ISO 7243:2018-01
7 Workplace environment − hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01

Reference standards (8)

PN-EN ISO 7243:2018-01
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 3 - p.11
PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05