🇵🇱 PRZEDSIĘBIORSTWO USŁUG PL

PCA AB 1067 • Łuków, Poland • 41 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO USŁUG is a laboratory accredited by PCA under number AB 1067 (Łuków, Poland). Its accreditation scope covers 41 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Water Wastewater, Wastewater, Water Water intended for human consumption Wastewater.

At a glance

  • Accreditation number: PCA AB 1067
  • Methods in scope: 41
  • Types of test objects: 5
  • City: Łuków, Poland
Accreditation number
AB 1067
Accreditation body
PCA
Address
I INŻYNIERII KOMUNALNEJ Sp. z o.o., ul. Partyzantów 6b, 21-400 Łuków, LABORATORIUM, ul. B. Prusa 14
City
Łuków, Poland

What this laboratory tests (5)

Accreditation scope — test methods (41)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water Water intended for human consumption Wastewater pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012
2 Water Water intended for human consumption Wastewater Nitrate nitrogen concentration Range: (0,10 – 50,0) mg/l Spectrophotometric method PN-82/C-04576/08
3 Water Water intended for human consumption Wastewater Nitrite nitrogen concentration Range: (0,002 – 20,0) mg/l Spectrophotometric method PN-EN 26777:1999
4 Water intended for human consumption Electrical conductivity Range: (15,0 – 20000) µS/cm Conductometric method PN-EN 27888:1999
5 Water intended for human consumption Iron concentration Range: (10 – 5000) µg/l Spectrophotometric method PB-11 wyd. 04/02.01.2020 na podstawie testu Merck 14761
6 Water intended for human consumption Manganese concentration Range: (10 – 500) µg/l Spectrophotometric method PB-18 wyd. 04/02.01.2020 na podstawie testu HACH LANGE LCW 532
7 Water intended for human consumption Colour Range: (5 – 70) mg/l Pt Visual method PN-EN ISO 7887:2012 metoda D +Ap1:2015-06
8 Water intended for human consumption Colour Range: (2 – 70) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
9 Water intended for human consumption Turbidity Range: (0,06 – 40) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
10 Water intended for human consumption Total calcium and magnesium content (total hardness) Range: (5 – 1000) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999
11 Water intended for human consumption Free chlorine concentration Range: (0,02 – 0,60) mg/l Visual method PB-16 wyd. 04/02.01.2020 na podstawie testu MACHEREY- NAGEL visocolor HE Chlor 920015
12 Water intended for human consumption Free chlorine concentration Range: (0,04 – 1,00) mg/l Colorimetric method PB-22 wyd. 01/15.06.2023 na podstawie testu Hach 8021
13 Water intended for human consumption Chloride concentration Range: (5,00 – 400) mg/l Titrimetric method PN-ISO 9297:1994
14 Water intended for human consumption Ammonium nitrogen concentration Range: (0,05 – 5,00) mg/l Spectrophotometric method PN-ISO 7150-1:2002
15 Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5:2017-10
16 Water Wastewater Biochemical oxygen demand - BOD 5 Range: (1 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12
17 Water Wastewater Biochemical oxygen demand - BOD 5 Range: (0,50 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002
18 Water Wastewater Chemical oxygen demand - COD-Cr Range: (10,0 – 10000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005
19 Water Wastewater Total suspended solids (TSS) Range: (2,0 – 5000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
20 Water Wastewater Total nitrogen concentration Range: (1,00 – 500) mg/l Spectrophotometric method PB-10 wyd. 04/02.01.2020 na podstawie testów: Merck 14537, 14763
21 Water Wastewater Total nitrogen concentration (calculated) PN-73/C-04576-14
22 Water Wastewater Kjeldahl nitrogen concentration Range: (1,00 – 300) mg/l Titrimetric method PN-EN 25663:2001
23 Water Wastewater Total phosphorus concentration Range: (0,050 – 200,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010
24 Water Wastewater Ammonium nitrogen concentration Range: (0,05 – 500) mg/l Spectrophotometric method PN-ISO 7150-1:2002
25 Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 pkt 7.4
26 Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature of the wastewater sample taken Range: (1,0 – 50,0) ºC PN-ISO 5667-10:2021-11 PN-77/C-04584
27 Wastewater Sulphate concentration Range: (10 – 1000) mg/l Gravimetric method PN-ISO 9280:2002
28 Wastewater Concentration of substances extractable with petroleum ether Range: (10 – 1000) mg/l Gravimetric method PB-20 wyd. 05/02.01.2020
29 Wastewater Dissolved solids Range: (300 – 6000)mg/l Gravimetric method PN-78/C-04541
30 Wastewater Chloride concentration Range: (5,00 – 1000) mg/l Titrimetric method PN-ISO 9297:1994
31 Wastewater Dissolved solids Range: (100 – 6000) mg/l Gravimetric method PN-EN 15216:2022-03
32 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
33 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
34 Water intended for human consumption Escherichia coli count Membrane filtration method
35 Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
36 Water intended for human consumption Most probable number of Escherichia coli MPN method
37 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
38 Water intended for human consumption Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004
39 Water intended for human consumption Total viable count at 22°C Plate method (pour plate)
40 Water intended for human consumption Threshold odour number TON Range: 1 Simplified method, paired, non-forced choice Threshold odour number TON Range: 1 – 64 Full method, paired, non-forced choice PN-EN 1622:2006
41 Water intended for human consumption Threshold flavour number TFN Range: 1 Simplified method, paired, non-forced choice Threshold flavour number TFN Range: 1 – 16 Full method, paired, non-forced choice

Reference standards (35)

PB-10 wyd. 04/02.01.2020 na podstawie testów: Merck 14537, 14763
PB-11 wyd. 04/02.01.2020 na podstawie testu Merck 14761
PB-16 wyd. 04/02.01.2020 na podstawie testu MACHEREY- NAGEL visocolor HE Chlor 920015
PB-18 wyd. 04/02.01.2020 na podstawie testu HACH LANGE LCW 532
PB-20 wyd. 05/02.01.2020
PB-22 wyd. 01/15.06.2023 na podstawie testu Hach 8021
PN-73/C-04576-14
PN-78/C-04541
PN-82/C-04576/08
PN-EN 15216:2022-03
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5667-6:2016-12 pkt 7.4
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
PN-EN ISO 7887:2012 metoda D +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994