🇵🇱 MOBILNE LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o. PL
Construction
MOBILNE LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o. is a laboratory accredited by PCA under number AB 1054 (Wałbrzych, Poland). Its accreditation scope covers 58 test methods in the following areas: Construction. Test objects include: Okna i drzwi balkonowe E, Okna, drzwi balkonowe i drzwi zewnętrzne E, Okna E, Windows E, Okna, drzwi zewnętrzne E, Windows, external doors E. Most frequently used techniques: Calculation method, Metoda Pomiar dynamicznej siły zamykającej metodą z obciążnikami.
At a glance
- Accreditation number: PCA AB 1054
- Methods in scope: 58
- Types of test objects: 18
- Techniques used: 2
- City: Wałbrzych, Poland
- Accreditation number
- AB 1054
- Accreditation body
- PCA
- Address
- ul. Jana Kasprowicza 21 lok. 2, 58-300 Wałbrzych, ul. Wrocławska 142B, 58-306 Wałbrzych, (stacjonarna działalność techniczna)
- City
- Wałbrzych, Poland
What this laboratory tests (18)
- Okna i drzwi balkonowe E — 9 methods
- Okna, drzwi balkonowe i drzwi zewnętrzne E — 8 methods
- Okna E, Windows E — 6 methods
- Okna, drzwi zewnętrzne E, Windows, external doors E — 6 methods
- Drzwi zewnętrzne E — 4 methods
- Drzwi wewnętrzne E — 3 methods
- Okładziny ścienne, pustaki szklane, drzwi zewnętrzne, bramy garażowe, świetliki, okna, żaluzje przeciw-burzowe, inne elementy przegród zewnętrznych budynku E, Wall cladding, glass block, exterior doors, garage doors, skylights, exterior windows, storm shutters and any other external component which help maintain the integrity of the building envelope E — 3 methods
- Okna, drzwi, drzwi balkonowe E — 3 methods
- Drzwi E — 2 methods
- Drzwi zewnętrzne E, External doors E — 2 methods
- Drzwi zewnętrzne i wewnętrzne, Okna, okna dachowe, okiennice, żaluzje, szyby, Ściany zewnętrzne, ściany wewnętrzne, bramy i ich elementy, Ściany osłonowe, Elementy budowlane, wentylacyjne i inne obiekty o powierzchni mniejszej niż 1m2 E — 2 methods
- Okna, drzwi zewnętrzne, ściany osłonowe E, Windows, external doors, curtain walls E — 2 methods
- Okna, okiennice, drzwi balkonowe i drzwi, rolety, żaluzje, ściany, bramy E — 2 methods
- Blinds E — 1 method
- Doors, windows, shutters, blinds and related building hardware — 1 method
- and 3 more
Analytical techniques used (2)
- Calculation method — 5 methods
- Metoda Pomiar dynamicznej siły zamykającej metodą z obciążnikami — 2 methods
Laboratory sections (2)
- MOBILNE LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o.; Stacjonarna działalność techniczna — 43 methods
- MOBILNE LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o.; Badania wykonywane poza siedzibą Laboratorium — 13 methods
Laboratory locations
- MOBILNE LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o.; Stacjonarna działalność techniczna — ul. Wrocławska 142B
- MOBILNE LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o.; Badania wykonywane poza siedzibą Laboratorium — ul. Jana Kasprowicza 21 lok. 2
Accreditation scope — test methods (58)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| MOBILNE LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o.; Stacjonarna działalność techniczna | |||||
| 1 | Okna, Windows | Wytrzymałość okuć dla skrzydeł otwieranych na zewnątrz, Casement hardware load test | AAMA/WDMA/CSA 101/1.S.2/A440:22 | ||
| 2 | Okna, okiennice, drzwi balkonowe i drzwi, rolety, żaluzje, ściany, bramy E | Dimensions Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
Procedura badawcza PB-01 | ||
| 3 | Okna, drzwi balkonowe i drzwi zewnętrzne E | Air permeability Regulated area: Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE / Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions 99/93/WE „N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
PN-EN 1026 „N” | ||
| 4 | Okna, drzwi balkonowe i drzwi zewnętrzne E | Watertightness Regulated area: Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE / Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions 99/93/WE „N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
PN-EN 1027 „N” | ||
| 5 | Okna, drzwi balkonowe i drzwi zewnętrzne E | Wytrzymałość na zginanie przez ściskanie zgrzewanych naroży Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
PN-EN 514 | ||
| 6 | Okna, drzwi balkonowe i drzwi zewnętrzne E | Thermal transmittance Regulated area: Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE / Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions 99/93/WE „N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Calculation method | PN-EN ISO 10077-1 „N” | PN-EN ISO 10077-2 „N” | |
| 7 | Okna, drzwi balkonowe i drzwi zewnętrzne E | Resistance to wind load Regulated area: Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE / Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions 99/93/WE „N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
PN-EN 12211 „N” | ||
| 8 | Okna i drzwi balkonowe E | Sound insulation Regulated area: Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE / Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions 99/93/WE „N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Calculation method | PN-EN 14351-1 „N” | |
| 9 | Okna i drzwi balkonowe E | Resistance to static torsion Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
PN-EN 14609 | ||
| 10 | Okna i drzwi balkonowe E | Load-bearing capacity of safety devices Regulated area: Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE / Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions 99/93/WE „N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
PN-EN 14609 „N” | PN-EN 14351-1 | ||
| 11 | Okna i drzwi balkonowe E | Operating forces Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
PN-EN 12046-1 | ||
| 12 | Okna i drzwi balkonowe E | Resistance to load in the plane of the leaf Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
PN-EN 14608 | ||
| 13 | Drzwi E | Operating forces Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
Metoda Pomiar dynamicznej siły zamykającej metodą z obciążnikami | PN-EN 12046-2 | |
| 14 | Drzwi zewnętrzne E | Resistance to static torsion Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
PN-EN 948 | ||
| 15 | Drzwi zewnętrzne E | Load-bearing capacity of safety devices Regulated area: Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE / Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions 99/93/WE „N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
PN-EN 948 „N” | PN-EN 14351-1 | ||
| 16 | Drzwi wewnętrzne E | Air permeability Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
PN-EN 1026 | ||
| 17 | Drzwi wewnętrzne E | Thermal transmittance Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
Calculation method | PN-EN ISO 10077-1 | PN-EN ISO 10077-2 | |
| 18 | Sekcje ram ścian osłonowych E | Thermal transmittance Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
Calculation method | PN-EN ISO 12631 | PN-EN ISO 10077-2 | |
| 19 | Blinds E | Thermal transmittance Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
Calculation method | PN-EN ISO 10077-2 | |
| 20 | Okna, drzwi, drzwi balkonowe E | Resistance to static load Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
PN-EN 1628 | ||
| 21 | Okna, drzwi, drzwi balkonowe E | Resistance to dynamic load Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
PN-EN 1629 | ||
| 22 | Okna, drzwi, drzwi balkonowe E | Resistance to manual burglary attempts Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
PN-EN 1630 | ||
| 23 | Drzwi zewnętrzne i wewnętrzne, Okna, okna dachowe, okiennice, żaluzje, szyby, Ściany zewnętrzne, ściany wewnętrzne, bramy i ich elementy, Ściany osłonowe, Elementy budowlane, wentylacyjne i inne obiekty o powierzchni mniejszej niż 1m2 E | Sound insulation Zakres częstotliwości środkowych pasm 1/3 okt. (50 ÷ 5000) Hz Regulated area: Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE / Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions 99/93/WE „N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
PN-EN ISO 10140-1 ,,N” | PN-EN ISO 10140-2 ,,N” | PN-EN ISO 10140-4 | PN-EN ISO 10140-5 | ||
| 24 | Drzwi zewnętrzne i wewnętrzne, Okna, okna dachowe, okiennice, żaluzje, szyby, Ściany zewnętrzne, ściany wewnętrzne, bramy i ich elementy, Ściany osłonowe, Elementy budowlane, wentylacyjne i inne obiekty o powierzchni mniejszej niż 1m2 E | Single-number airborne sound reduction index together with the spectrum adaptation terms (calculated) Regulated area: Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE / Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions 99/93/WE „N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
PN-EN ISO 717-1 ,,N” | ||
| 25 | Okna, drzwi zewnętrzne E, Windows, external doors E | Sztywność i wytrzymałość przy obciążeniu ciśnieniem statycznym, Structural performance by uniform static air pressure difference Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
ASTM E330/E330M | AAMA/WDMA/CSA 101/1.S.2/A440 | ||
| 26 | Okna, drzwi zewnętrzne E, Windows, external doors E | Przepuszczalność powietrza przy określonej różnicy ciśnień, Determining rate of air leakage under specified pressure differences across the specimen Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
ASTM E283/E283M | AAMA/WDMA/CSA 101/1.S.2/A440 | CSA A440S1 | ||
| 27 | Okna, drzwi zewnętrzne E, Windows, external doors E | Wodoszczelność przy statycznej różnicy ciśnień, Water penetration by uniform static air pressure difference Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
ASTM E331 | AAMA/WDMA/CSA 101/1.S.2/A440 | CSA A440S1 | ||
| 28 | Okna, drzwi zewnętrzne E, Windows, external doors E | Wodoszczelność przy cyklicznej statycznej różnicy ciśnień, Water penetration by cyclic static air pressure difference Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
ASTM E547 | AAMA/WDMA/CSA 101/1.S.2/A440 | CSA A440S1 | ||
| 29 | Okna, drzwi zewnętrzne E, Windows, external doors E | Siły operacyjne, Operating force Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
ASTM E2068 | AAMA/WDMA/CSA 101/1.S.2/A440 | CSA A440S1 | ||
| 30 | Okna, drzwi zewnętrzne E, Windows, external doors E | Wytrzymałość zgrzewanych połączeń PVC, Thermoplastic corner weld test Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
AAMA/WDMA/CSA 101/1.S.2/A440 | ||
| 31 | Okna E, Windows E | Próba odszklenia, Deglazing test Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
ASTM E987 | AAMA/WDMA/CSA 101/1.S.2/A440 | ||
| 32 | Okna E, Windows E | Odporność na włamanie, Forced entry resistance test Range Stopień 10, 20, 30, 40 Scope Grade 10, 20, 30, 40 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
ASTM F588 | AAMA/WDMA/CSA 101/1.S.2/A440 | ||
| 33 | Okna E, Windows E | Skręcanie skrzydła, Sash/leaf torsion test Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
AAMA/WDMA/CSA 101/1.S.2/A440 | ||
| 34 | Okna E, Windows E | Wytrzymałość okuć, Awning, hopper, projected hardware load test Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
AAMA/WDMA/CSA 101/1.S.2/A440 | ||
| 35 | Okna E, Windows E | Obciążenie skrzydła z zasuwnicą, Sash/leaf concentrated load test on latch rail Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
AAMA/WDMA/CSA 101/1.S.2/A440 | ||
| 36 | Okna E, Windows E | Wytrzymałość ramienia stabilizującego, Stabilizing arm load test Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
AAMA/WDMA/CSA 101/1.S.2/A440 | ||
| 37 | Drzwi zewnętrzne E, External doors E | Siła potrzebna do zatrzaśnięcia skrzydła, Force-to-latch test procedure (for latch) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
AAMA/WDMA/CSA 101/1.S.2/A440 | ||
| 38 | Drzwi zewnętrzne E, External doors E | Siła, moment siły potrzebne do zamknięcia zasuwki zamka, Force-to-engage test procedure (for deadbolt) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
AAMA/WDMA/CSA 101/1.S.2/A440 | ||
| 39 | Okna, drzwi zewnętrzne, ściany osłonowe E, Windows, external doors, curtain walls E | Odporność na uderzenie pociskiem, Windborne debris in hurricanes (Impact test) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
ASTM E1996 | ||
| 40 | Okna, drzwi zewnętrzne, ściany osłonowe E, Windows, external doors, curtain walls E | Odporność na cykliczną różnicę ciśnień, Cyclic pressure differentials Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
ASTM E1886 | ||
| 41 | Okładziny ścienne, pustaki szklane, drzwi zewnętrzne, bramy garażowe, świetliki, okna, żaluzje przeciw-burzowe, inne elementy przegród zewnętrznych budynku E, Wall cladding, glass block, exterior doors, garage doors, skylights, exterior windows, storm shutters and any other external component which help maintain the integrity of the building envelope E | Odporność na uderzenie pociskiem, Impact test Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
Testing Application Standard (Tas) 201 | ||
| 42 | Okładziny ścienne, pustaki szklane, drzwi zewnętrzne, bramy garażowe, świetliki, okna, żaluzje przeciw-burzowe, inne elementy przegród zewnętrznych budynku E, Wall cladding, glass block, exterior doors, garage doors, skylights, exterior windows, storm shutters and any other external component which help maintain the integrity of the building envelope E | Obciążenie przy równomiernym statycznym ciśnieniu powietrza, Uniform static air pressure difference Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
Testing Application Standard (Tas) 202 | ||
| 43 | Okładziny ścienne, pustaki szklane, drzwi zewnętrzne, bramy garażowe, świetliki, okna, żaluzje przeciw-burzowe, inne elementy przegród zewnętrznych budynku E, Wall cladding, glass block, exterior doors, garage doors, skylights, exterior windows, storm shutters and any other external component which help maintain the integrity of the building envelope E | Odporność na cykliczne obciążenie ciśnieniem wiatru, Cyclic wind pressure loading Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
Testing Application Standard (Tas) 203 | ||
| MOBILNE LABORATORIUM TECHNIKI BUDOWLANEJ Sp. z o.o.; Badania wykonywane poza siedzibą Laboratorium | |||||
| 44 | Okna, okiennice, drzwi balkonowe i drzwi, rolety, żaluzje, ściany, bramy E | Dimensions Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
Procedura badawcza PB-01 | ||
| 45 | Okna, drzwi balkonowe i drzwi zewnętrzne E | Air permeability Regulated area: Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE / Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions 99/93/WE „N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
PN-EN 1026 „N” | ||
| 46 | Okna, drzwi balkonowe i drzwi zewnętrzne E | Watertightness Regulated area: Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE / Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions 99/93/WE „N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
PN-EN 1027 „N” | ||
| 47 | Okna, drzwi balkonowe i drzwi zewnętrzne E | Resistance to wind load Regulated area: Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE / Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions 99/93/WE „N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
PN-EN 12211 „N” | ||
| 48 | Drzwi wewnętrzne E | Air permeability Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
PN-EN 1026 | ||
| 49 | Okna i drzwi balkonowe E | Resistance to static torsion Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
PN-EN 14609 | ||
| 50 | Okna i drzwi balkonowe E | Load-bearing capacity of safety devices Regulated area: Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE / Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions 99/93/WE „N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
PN-EN 14609 „N” | PN-EN 14351-1 | ||
| 51 | Okna i drzwi balkonowe E | Operating forces Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
PN-EN 12046-1 | ||
| 52 | Okna i drzwi balkonowe E | Resistance to load in the plane of the leaf Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
PN-EN 14608 | ||
| 53 | Drzwi E | Operating forces Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
Metoda Pomiar dynamicznej siły zamykającej metodą z obciążnikami | PN-EN 12046-2 | |
| 54 | Drzwi zewnętrzne E | Resistance to static torsion Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
PN-EN 948 | ||
| 55 | Drzwi zewnętrzne E | Load-bearing capacity of safety devices Regulated area: Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE / Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions 99/93/WE „N” – Metoda badawcza stosowana w działaniach właściwych dla notyfikacji wg Rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011 z dnia 9 marca 2011 r. E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
PN-EN 948 „N” | PN-EN 14351-1 | ||
| 56 | Ściany osłonowe, okna i drzwi zewnętrzne E | Watertightness Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available by the accredited body. |
PN-EN 13051 | ||
| Test methods | |||||
| 57 | Doors, windows, shutters, blinds and related building hardware | OCENA WŁAŚCIWOŚCI UŻYTKOWYCH NA PODSTAWIE BADAŃ, OBLICZEŃ I TABELARYCZNYCH WARTOŚCI (System 3) Commission decision number 99/93/WE Product(s) Drzwi, okna, okiennice, żaluzje i powiązane z nimi okucia budowlane Zharmonizowane specyfikacje techniczne EN 14351-1:2006+A2:2016 Regulated area: Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE / Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions 99/93/WE Laboratorium spełnia wymagania określone w Rozporządzeniu Nr 305/2011 z dnia 9 marca 2011 r. w zakresie prowadzonej działalności przewidzianej dla laboratorium badawczego (Załącznik V, pkt 2, ppkt. 3 Rozporządzenia Nr 305/2011) w powyższym zakresie. Aktualna „Lista podwykonawców” jest dostępna na każde żądanie w akredytowanym podmiocie. |
EN 14351-1:2006+A2:2016 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011 z późn. zm.) | ||
| 58 | OCENA WŁAŚCIWOŚCI UŻYTKOWYCH Zasadnicza charakterystyka Izolacyjność akustyczna Specyfikacja techniczna EN ISO 10140-1:2021-10 Regulated area: Ocena zgodności w obszarze rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 (CPR), decyzja KE: 99/93/WE / Conformity assessment for EU Regulation No 305/2011 (CPR), EC decisions 99/93/WE Laboratorium spełnia wymagania określone w Rozporządzeniu Nr 305/2011 z dnia 9 marca 2011 r. w zakresie prowadzonej działalności przewidzianej dla laboratorium badawczego (Załącznik V, pkt 2, ppkt. 3 Rozporządzenia Nr 305/2011) w powyższym zakresie. |
EN ISO 10140-1:2021-10 | Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011 z późn. zm.) | |||
Reference standards (47)
AAMA/WDMA/CSA 101/1.S.2/A440
AAMA/WDMA/CSA 101/1.S.2/A440:22
ASTM E1886
ASTM E1996
ASTM E2068
ASTM E283/E283M
ASTM E330/E330M
ASTM E331
ASTM E547
ASTM E987
ASTM F588
CSA A440S1
EN 14351-1:2006+A2:2016
EN ISO 10140-1:2021-10
PN-EN 1026
PN-EN 1026 „N”
PN-EN 1027 „N”
PN-EN 12046-1
PN-EN 12046-2
PN-EN 12211 „N”
PN-EN 13051
PN-EN 14351-1
PN-EN 14351-1 „N”
PN-EN 14608
PN-EN 14609
PN-EN 14609 „N”
PN-EN 1628
PN-EN 1629
PN-EN 1630
PN-EN 514
PN-EN 948
PN-EN 948 „N”
PN-EN ISO 10077-1
PN-EN ISO 10077-1 „N”
PN-EN ISO 10077-2
PN-EN ISO 10077-2 „N”
PN-EN ISO 10140-1 ,,N”
PN-EN ISO 10140-2 ,,N”
PN-EN ISO 10140-4
PN-EN ISO 10140-5
PN-EN ISO 12631
PN-EN ISO 717-1 ,,N”
Procedura badawcza PB-01
Rozporządzenie Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. ustanawiające zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylające dyrektywę Rady 89/106/EWG (Dz. Urz. UE L 88 z 4.4.2011 z późn. zm.)
Testing Application Standard (Tas) 201
Testing Application Standard (Tas) 202
Testing Application Standard (Tas) 203