🇵🇱 AKADEMIA GÓRNICZO-HUTNICZA PL

PCA AB 1050 • Kraków, Poland • 13 methods

Water & wastewater

AKADEMIA GÓRNICZO-HUTNICZA is a laboratory accredited by PCA under number AB 1050 (Kraków, Poland). Its accreditation scope covers 13 test methods in the following areas: Water & wastewater. Test objects include: Water. Most frequently used techniques: Inductively coupled plasma mass spectrometry (ICP-MS), Titrimetric method, Conductometric method.

At a glance

  • Accreditation number: PCA AB 1050
  • Methods in scope: 13
  • Types of test objects: 1
  • Techniques used: 6
  • City: Kraków, Poland
Accreditation number
AB 1050
Accreditation body
PCA
Address
im. STANISŁAWA STASZICA w KRAKOWIE, WYDZIAŁ GEOLOGII, GEOFIZYKI I OCHRONY ŚRODOWISKA, KATEDRA HYDROGEOLOGII I GEOLOGII INŻYNIERSKIEJ, LABORATORIUM HYDROGEOCHEMICZNE, Al. Mickiewicza 30
City
Kraków, Poland

What this laboratory tests (1)

Analytical techniques used (6)

Laboratory locations

Accreditation scope — test methods (13)

No. Test object Methodology / Parameters Technique Reference document
Laboratorium Hydrogeochemiczne; Al. Mickiewicza 30, 30-059 Kraków
1 Water Sampling for physical and chemical testing PN-ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 i 7.6 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2 i 6.3
2 Water Element concentration
Ag (0,050 – 50,0) µg/l Al (0,50 – 100,0) µg/l As (0,10 – 100,0) µg/ B (1,0 – 1000) µg/l Ba (0,20 – 50,0) µg/l Be (0,010 – 50,0) µg/l Bi (0,0050 – 50,0) µg/l Cd (0,020 – 50,0) µg/l Co (0,010 – 50,0) µg/l Cr (0,050 – 50,0) µg/l Cu (0,10 – 100,0) µg/l Cs (0,0050 – 50,0) µg/l Fe (0,10 – 100,0) µg/l Ga (0,020 – 100,0) µg/l Hg (0,020 – 20,0) µg/l Li (0,050 – 100,0) µg/l Mn (0,10 – 50,0) µg/l Mo (0,020 – 50,0) µg/l Ni (0,10 – 50,0) µg/l Pb (0,050 – 50,0) µg/l Rb (0,20 – 100,0) µg/l Sb (0,010 – 50,0) µg/l Se (1,0 – 100,0) µg/l Sn (0,025 – 50,0) µg/l Sr (0,050 – 100,0) µg/l Ti (1,0 – 100,0) µg/l Tl (0,0050 – 50,0) µg/l U (0,00050 –10,0) µg/l V (0,050 – 50,0) µg/l W (0,010 – 50,0) µg/l Y (0,010 – 50,0) µg/l Zn (1,0 – 100,0) µg/l Zr (0,050 – 50,0) µg/l P (10,0 – 100,0) µg/l
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04
3 Water Stężenie fosforanów, PO 43- (z obliczeń) PN-EN ISO 17294-2:2024-04
4 Water Element concentration
Ag (0,0050 – 1,0) mg/l Al (0,0025 – 5,0) mg/l As (0,0050 – 1,0) mg/l B (0,0020 – 100,0) mg/l Ba (0,00025 – 10,0) mg/l Be (0,00050 – 1,0) mg/l Ca (0,10 – 5000) mg/l Cd (0,0010 – 1,0) mg/l Co (0,0010 – 1,0) mg/l Cr (0,0010 – 10,0) mg/l Cu (0,0050 – 5,0) mg/l Fe (0,00050 – 100,0) mg/l K (0,20 – 2000) mg/l Li (0,0050 – 20,0) mg/l Mg (0,050 – 2000) mg/l Mn (0,00020 – 1,0) mg/l Mo (0,0025 – 1,0) mg/l Na (0,1 – 10 000) mg/l Ni (0,0020 – 10,0) mg/l P (0,010 – 5,0) mg/l Pb (0,0050 – 10,0) mg/l S (0,20 – 2000) mg/l Si (0,10 – 50,0) mg/l Sr (0,00020 – 20,0) mg/l Ti (0,0020 – 1,0) mg/l Tl (0,010 – 1,0) mg/l V (0,0020 – 1,0) mg/l Zn (0,0010 – 50,0) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
5 Water Stężenie fosforanów, PO43- (z obliczeń) PN-EN ISO 11885:2009
6 Water Stężenie krzemionki, SiO 2 (z obliczeń) PN-EN ISO 11885:2009
7 Water Stężenie siarczanów, SO42- (z obliczeń) PN-EN ISO 11885:2009
8 Water Element concentration
Br (0,0020 – 100,0) mg/l I (0,0020 – 100,0) mg/l
Inductively coupled plasma mass spectrometry (ICP-MS) PB-01 wydanie 5 z dnia 13.01.2025
9 Water Chloride concentration
Chloride concentration (1,0 – 10 000) mg/l
Titrimetric method PN-ISO 9297:1994
10 Water pH
pH 4,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
11 Water Alkalinity
Alkalinity (0,4 – 20,0) mmol/l Alkalinity (24,4 – 1220) mg/l HCO3 Alkalinity (20,0 – 1000) mg/l CaCO3
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
12 Water Electrical conductivity
Electrical conductivity 10 μS/cm – 20,0 mS/cm
Conductometric method PN-EN 27888:1999
13 Water Stężenie anionów rozpuszczonych
Bromides (0,10 – 100) mg/l Chlorides (0,40 – 100) mg/l Fluorides (0,040 – 10,0) mg/l Nitrites (0,050 – 5,0) mg/l Nitrates (0,10 – 50,0) mg/l Phosphates (0,20 – 10,0) mg/l Sulfates (0,50 – 5000) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012

Reference standards (10)

PB-01 wydanie 5 z dnia 13.01.2025
PN-EN 27888:1999
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 11885:2009
PN-EN ISO 17294-2:2024-04
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2 i 6.3
PN-ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 i 7.6
PN-ISO 9297:1994