AKADEMIA GÓRNICZO-HUTNICZA is a laboratory accredited by PCA under number AB 1050 (Kraków, Poland). Its accreditation scope covers 13 test methods in the following areas: Water & wastewater. Test objects include: Water. Most frequently used techniques: Inductively coupled plasma mass spectrometry (ICP-MS), Titrimetric method, Conductometric method.

At a glance

  • Accreditation number: PCA AB 1050
  • Methods in scope: 13
  • Types of test objects: 1
  • Techniques used: 6
  • City: Kraków, Poland
Accreditation number
AB 1050
Accreditation body
PCA
Address
im. STANISŁAWA STASZICA w KRAKOWIE, WYDZIAŁ GEOLOGII, GEOFIZYKI I OCHRONY ŚRODOWISKA, KATEDRA HYDROGEOLOGII I GEOLOGII INŻYNIERSKIEJ, LABORATORIUM HYDROGEOCHEMICZNE, Al. Mickiewicza 30
City
Kraków, Poland

What this laboratory tests (1)

Analytical techniques used (6)

Laboratory locations

Certificate information

Issue date
07.04.2026
Issue no.
17

Accreditation scope — test methods (13)

No. Test object Methodology / Parameters Technique Reference document
Laboratorium Hydrogeochemiczne; Al. Mickiewicza 30, 30-059 Kraków
1 Water Sampling for physical and chemical testing PN-ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 i 7.6 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2 i 6.3
2 Water Element concentration
Ag (0,050 – 50,0) µg/l Al (0,50 – 100,0) µg/l As (0,10 – 100,0) µg/ B (1,0 – 1000) µg/l Ba (0,20 – 50,0) µg/l Be (0,010 – 50,0) µg/l Bi (0,0050 – 50,0) µg/l Cd (0,020 – 50,0) µg/l Co (0,010 – 50,0) µg/l Cr (0,050 – 50,0) µg/l Cu (0,10 – 100,0) µg/l Cs (0,0050 – 50,0) µg/l Fe (0,10 – 100,0) µg/l Ga (0,020 – 100,0) µg/l Hg (0,020 – 20,0) µg/l Li (0,050 – 100,0) µg/l Mn (0,10 – 50,0) µg/l Mo (0,020 – 50,0) µg/l Ni (0,10 – 50,0) µg/l Pb (0,050 – 50,0) µg/l Rb (0,20 – 100,0) µg/l Sb (0,010 – 50,0) µg/l Se (1,0 – 100,0) µg/l Sn (0,025 – 50,0) µg/l Sr (0,050 – 100,0) µg/l Ti (1,0 – 100,0) µg/l Tl (0,0050 – 50,0) µg/l U (0,00050 –10,0) µg/l V (0,050 – 50,0) µg/l W (0,010 – 50,0) µg/l Y (0,010 – 50,0) µg/l Zn (1,0 – 100,0) µg/l Zr (0,050 – 50,0) µg/l P (10,0 – 100,0) µg/l
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04
3 Water Stężenie fosforanów, PO43- (z obliczeń) PN-EN ISO 17294-2:2024-04
4 Water Element concentration
Ag (0,0050 – 1,0) mg/l Al (0,0025 – 5,0) mg/l As (0,0050 – 1,0) mg/l B (0,0020 – 100,0) mg/l Ba (0,00025 – 10,0) mg/l Be (0,00050 – 1,0) mg/l Ca (0,10 – 5000) mg/l Cd (0,0010 – 1,0) mg/l Co (0,0010 – 1,0) mg/l Cr (0,0010 – 10,0) mg/l Cu (0,0050 – 5,0) mg/l Fe (0,00050 – 100,0) mg/l K (0,20 – 2000) mg/l Li (0,0050 – 20,0) mg/l Mg (0,050 – 2000) mg/l Mn (0,00020 – 1,0) mg/l Mo (0,0025 – 1,0) mg/l Na (0,1 – 10 000) mg/l Ni (0,0020 – 10,0) mg/l P (0,010 – 5,0) mg/l Pb (0,0050 – 10,0) mg/l S (0,20 – 2000) mg/l Si (0,10 – 50,0) mg/l Sr (0,00020 – 20,0) mg/l Ti (0,0020 – 1,0) mg/l Tl (0,010 – 1,0) mg/l V (0,0020 – 1,0) mg/l Zn (0,0010 – 50,0) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
5 Water Stężenie fosforanów, PO43- (z obliczeń) PN-EN ISO 11885:2009
6 Water Stężenie krzemionki, SiO2 (z obliczeń) PN-EN ISO 11885:2009
7 Water Stężenie siarczanów, SO42- (z obliczeń) PN-EN ISO 11885:2009
8 Water Element concentration
Br (0,0020 – 100,0) mg/l I (0,0020 – 100,0) mg/l
Inductively coupled plasma mass spectrometry (ICP-MS) PB-01 wydanie 5 z dnia 13.01.2025
9 Water Chloride concentration
Chloride concentration (1,0 – 10 000) mg/l
Titrimetric method PN-ISO 9297:1994
10 Water pH
pH 4,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
11 Water Alkalinity
Alkalinity (0,4 – 20,0) mmol/l Alkalinity (24,4 – 1220) mg/l HCO3 Alkalinity (20,0 – 1000) mg/l CaCO3
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
12 Water Electrical conductivity
Electrical conductivity 10 μS/cm – 20,0 mS/cm
Conductometric method PN-EN 27888:1999
13 Water Stężenie anionów rozpuszczonych
Bromides (0,10 – 100) mg/l Chlorides (0,40 – 100) mg/l Fluorides (0,040 – 10,0) mg/l Nitrites (0,050 – 5,0) mg/l Nitrates (0,10 – 50,0) mg/l Phosphates (0,20 – 10,0) mg/l Sulfates (0,50 – 5000) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012

Reference standards (10)

PB-01 wydanie 5 z dnia 13.01.2025
PN-EN 27888:1999
PN-EN ISO 10304-1:2009+AC:2012