🇵🇱 WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ PL

PCA AB 1042 • Wrocław, Poland • 48 methods

EnvironmentElectronics & EMCWater & wastewater

WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ is a laboratory accredited by PCA under number AB 1042 (Wrocław, Poland). Its accreditation scope covers 48 test methods in the following areas: Environment, Electronics & EMC, Water & wastewater. Test objects include: Water intended for human consumption, Workplace environment - air, Workplace environment - electromagnetic field in the workspace from…, Workplace environment - electromagnetic field in the workspace orig….

At a glance

  • Accreditation number: PCA AB 1042
  • Methods in scope: 48
  • Types of test objects: 20
  • City: Wrocław, Poland
Accreditation number
AB 1042
Accreditation body
PCA
Address
WE WROCŁAWIU, ZESPÓŁ LABORATORYJNY, ul. Ślężna 158
City
Wrocław, Poland

What this laboratory tests (20)

Accreditation scope — test methods (48)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment - indoor electric lighting Illuminance Range: (5-10 000) lx Direct measurement method PN-83/E-4040.03 PB-01/LBŚP wydanie 3 z 07.03.2023 r.
2 Workplace environment - indoor electric lighting Lighting uniformity ( calculated)
3 Workplace environment - noise A-weighted equivalent sound level A-weighted maximum sound level Range: (35 – 135) dB C-weighted peak sound level Range: (35 – 135) dB Direct measurement method PN-N-01307:1994 PN-ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2
4 Workplace environment - noise Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)
5 Workplace environment - air Air sampling for occupational exposure assessment to dust agents - inhalable fraction Personal dosimetry method PN-Z-04008-7:2002
6 Workplace environment - air Exposure index (calculated)
7 Workplace environment - air Concentration of harmful dust agents - inhalable fraction - wood dust Range (0,30 – 30,0) mg/m3 Gravimetric method PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08
8 Workplace environment - moderate microclimate Air temperature Range: (5 – 40) °C Black globe temperature Range: (5 – 40) °C Air humidity Range: (25 – 80) % Air velocity Range: (0,15 – 5,0) m/s Direct measurement method PN-EN ISO 7730:2006 + Ap:2016-04
9 Workplace environment - moderate microclimate PMV index PPD index (calculated)
10 Workplace environment - electromagnetic field in the workspace from stationary communication equipment Electric field strength: - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 600 MHz range: (1,0 - 400) V/m Direct measurement method NO-06-A215-2 | ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań
11 Workplace environment - electromagnetic field in the workspace from stationary communication equipment Magnetic field strength - from 1,6 MHz to 600 MHz Range: (0,01 – 15,0) A/m Direct measurement method
12 Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment Electric field strength: - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 18 GHz range: (1,0 - 400) V/m Direct measurement method NO-06-A215-2 | ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań
13 Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment Magnetic field strength from 1,6 MHz to 1 GHz Range: (0,01 – 15,0) A/m Direct measurement method
14 Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment Magnetic field strength from 1 GHz to 18 GHz (calculated)
15 Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Electric field strength - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 600 MHz range: (1,0 - 400) V/m Direct measurement method NO-06-A215-2 | ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań
16 Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Magnetic field strength - from 1,6 MHz to 10 MHz range: (0,02 - 110) A/m - from 10 MHz to 30 MHz range: (0,02 - 15) A/m - from 27 MHz to 600 MHz range: (0,01 – 2,0) A/m Direct measurement method
17 Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Electric field strength - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 1 GHz Range: (1,0 - 400) V/m Direct measurement method NO-06-A215-2 | ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań
18 Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Magnetic field strength from 1,6 MHz to 1 GHz range: (0,015 – 15) A/m Direct measurement method
19 Workplace environment - electromagnetic field in the workspace originating from mobile communication devices Electric field strength: - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 18 GHz range: (1,0 - 400) V/m Direct measurement method NO-06-A215-2 | ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań
20 Workplace environment - electromagnetic field in the workspace originating from mobile communication devices Magnetic field strength from 1,6 MHz to 1 GHz Range: (0,01 – 15,0) A/m Direct measurement method
21 Workplace environment - electromagnetic field in the workspace originating from mobile communication devices Magnetic field strength from 1 GHz to 18 GHz (calculated)
22 Workplace environment - electromagnetic field in the workspace from medical magnetotherapy equipment Magnetic flux density in the frequency range - from 20 Hz to 50 Hz range: (0,020 – 50,0) mT Direct (simplified) measurement method Magnetic field strength in the frequency range from 20 Hz to 50 Hz (calculated) Podstawy i Metodyki Oceny Środowiska Pracy 2016, nr 4, s. 151- 180
23 Canned products in metal packaging – meat and meat products Shelf stability of canned products Incubation method PN-A-82055-5:1994 z wyłączeniem punktu 2.5.3. z wyłączeniem pobierania próbek
24 Canned products in metal packaging – meat and meat products Leak tightness of cans Vacuum method PN-A-82055-4:1997+Az1:2002 z wyłączeniem punktu 2.4.1.3
25 Canned products in tin packaging – fruit, vegetable and vegetable-meat preserves Shelf stability of canned products Incubation method PN-90/A-75052/03
26 Canned products in tin packaging – fruit, vegetable and vegetable-meat preserves Leak tightness of cans Vacuum method PN-90/A-75052/02 z wyłączeniem punktu 2.2.3
27 Canned products in tin packaging – canned fish Shelf stability of canned products Incubation method PN – 92/A-86732 pkt. 2.3.11. z wyłączeniem pobierania próbek
28 Canned products in tin packaging – canned fish Leak tightness of cans Vacuum method PN – 92/A-86732 pkt. 2.3.10. z wyłączeniem pobierania próbek
29 Canned products in hermetically sealed packaging Sterilised soups Shelf stability of canned products Incubation method NO-89-A208:2015 p.4.6 PN – 90/A – 75052 -03
30 Canned products in hermetically sealed packaging Sterilised soups Leak tightness of cans Vacuum method NO-89-A208:2015 p.4.7
31 Canned products in hermetically sealed packaging Sterilised canned poultry Shelf stability of canned products Incubation method NO-89-A203 | PN-A-82055-5:1994 z wyłączeniem punktu 2.5.3. z wyłączeniem pobierania próbek
32 Canned products in hermetically sealed packaging Sterilised canned poultry Leak tightness of cans Vacuum method NO-89-A203 | PN-A-82055-4:1997 + Az1:2002 z wyłączeniem pkt 2.4.1.3.
33 Canned products in hermetically sealed packaging Sterilised canned vegetable – meat and meatless products Shelf stability of canned products Incubation method NO-89-A202:2015 p.4.6 PN - 90/A - 75052-03:1990
34 Canned products in hermetically sealed packaging Sterilised canned vegetable – meat and meatless products Leak tightness of cans Vacuum method NO-89-A202:2015 p.4.7
35 Canned products in hermetically sealed packaging Sterilised canned meat Shelf stability of canned products Incubation method NO-89-A201 | PN-A-82055-5:1994 z wyłączeniem punktu 2.5.3 z wyłączeniem pobierania próbek
36 Canned products in hermetically sealed packaging Sterilised canned meat Leak tightness of cans Vacuum method NO-89-A201 | PN-A-82055 - 4:1997 + Az1:2002 z wyłączeniem pkt 2.4.1.3
37 Water intended for human consumption pH Range: 4 – 10 Potentiometric method EN ISO 10523:2012
38 Water intended for human consumption Specific conductivity Range: (100 – 1500) μS/cm Conductometric method PN-EN 27888:1999
39 Water intended for human consumption Turbidity Range: (0, 1 – 40) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
40 Water intended for human consumption Iron concentration Range: (0,02– 1,0) mg/l Spectrophotometric method PB - 07/ LBŻiW wyd. 7 z dn. 22.11.2016 r.
41 Water intended for human consumption Manganese concentration Range: (0,02 – 0,1) mg/l Spectrophotometric method PB - 06/ LBŻiW wyd.7 z dn. 22.11.2016 r.
42 Water intended for human consumption Nitrite nitrogen concentration Range: (0,01 – 0,15) mg/l Spectrophotometric method PB - 04/LBŻiW wyd. 8 z dn. 22.03.2024 r.
43 Water intended for human consumption Nitrite concentration Range: (0,033 – 0,495) mg/l (calculated)
44 Water intended for human consumption Ammonium nitrogen concentration Range: (0,03 – 0,40) mg/l Spectrophotometric method PB - 02/LBŻiW wyd. 8 z dn. 22.03.2024 r.
45 Water intended for human consumption Ammonium ion concentration Range: (0,04– 0,52) mg/l (calculated)
46 Water intended for human consumption Total count of microorganisms at 22ºC Plate method (pour plate) PN-EN ISO 6222:2004
47 Swimming pool water Total count of microorganisms at 36ºC Plate method (pour plate) PN-EN ISO 6222:2004
48 Faeces, rectal swab Presence of rods of the genus Salmonella, Shigella Culture method with biochemical and serological confirmation Procedura badawcza Nr PB – 01/LM wydanie nr 7 z dnia 15.03.2022 r. w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego, PZH i KIDL, Warszawa 2015

Reference standards (32)

EN ISO 10523:2012
NO-06-A215-2
NO-89-A201
NO-89-A202:2015 p.4.6 PN - 90/A - 75052-03:1990
NO-89-A202:2015 p.4.7
NO-89-A203
NO-89-A208:2015 p.4.6 PN – 90/A – 75052 -03
NO-89-A208:2015 p.4.7
PB - 02/LBŻiW wyd. 8 z dn. 22.03.2024 r.
PB - 04/LBŻiW wyd. 8 z dn. 22.03.2024 r.
PB - 06/ LBŻiW wyd.7 z dn. 22.11.2016 r.
PB - 07/ LBŻiW wyd. 7 z dn. 22.11.2016 r.
PN – 92/A-86732 pkt. 2.3.10. z wyłączeniem pobierania próbek
PN – 92/A-86732 pkt. 2.3.11. z wyłączeniem pobierania próbek
PN-83/E-4040.03 PB-01/LBŚP wydanie 3 z 07.03.2023 r.
PN-90/A-75052/02 z wyłączeniem punktu 2.2.3
PN-90/A-75052/03
PN-A-82055 - 4:1997 + Az1:2002 z wyłączeniem pkt 2.4.1.3
PN-A-82055-4:1997 + Az1:2002 z wyłączeniem pkt 2.4.1.3.
PN-A-82055-4:1997+Az1:2002 z wyłączeniem punktu 2.4.1.3
PN-A-82055-5:1994 z wyłączeniem punktu 2.5.3 z wyłączeniem pobierania próbek
PN-A-82055-5:1994 z wyłączeniem punktu 2.5.3. z wyłączeniem pobierania próbek
PN-EN 27888:1999
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7730:2006 + Ap:2016-04
PN-N-01307:1994 PN-ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2
PN-Z-04008-7:2002
PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08
Podstawy i Metodyki Oceny Środowiska Pracy 2016, nr 4, s. 151- 180
Procedura badawcza Nr PB – 01/LM wydanie nr 7 z dnia 15.03.2022 r. w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego, PZH i KIDL, Warszawa 2015
ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań