🇵🇱 ZAKŁAD WODOCIĄGÓW I KANALIZACJI PL

PCA AB 1041 • Nowa Ruda, Poland • 49 methods

Water & wastewaterMicrobiology

ZAKŁAD WODOCIĄGÓW I KANALIZACJI is a laboratory accredited by PCA under number AB 1041 (Nowa Ruda, Poland). Its accreditation scope covers 49 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Swimming pool water, Water, water intended for human consumption, Water intended for human consumption, Wastewater.

At a glance

  • Accreditation number: PCA AB 1041
  • Methods in scope: 49
  • Types of test objects: 8
  • City: Nowa Ruda, Poland
Accreditation number
AB 1041
Accreditation body
PCA
Address
SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ, ul. Niepodległości 56, 57-400 Nowa Ruda, LABORATORIUM BADANIA WODY I ŚCIEKÓW, W ŚCINAWCE DOLNEJ
City
Nowa Ruda, Poland

What this laboratory tests (8)

Accreditation scope — test methods (49)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
2 Water intended for human consumption Free chlorine concentration Range: (0,05 − 6,0) mg/l Spectrophotometric method PB-14 wydanie 2 z dnia 27.11.2024 r. na podstawie testów 7-20/936220/Macherey-Nagel, 7-21/936221/Macherey-Nagel
3 Water, water intended for human consumption Ammonium ion concentration Range: (0,013 − 0,600) mg/l (0,010 − 0,500) mg/l N-NH + 4 Spectrophotometric method PB-05 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14752
4 Water, water intended for human consumption Nitrate concentration Range: (0,9 – 60,0) mg/l (0,2 – 13,6) mg/l N-NO - 3 Spectrophotometric method PB-04 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14773
5 Water, water intended for human consumption pH Range: 4,0 − 9,0 Potentiometric method PN-EN ISO 10523:2012
6 Water, water intended for human consumption Electrical conductivity Range: (100 – 3000) µS/cm Conductometric method PN-EN 27888:1999
7 Water, water intended for human consumption Iron concentration Range: (0,005 − 1,000) mg/l Spectrophotometric method PB-01 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14761
8 Water, water intended for human consumption Turbidity Range: (0,10 − 10,0) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
9 Water, water intended for human consumption Nitrite concentration Range: (0,007 − 0,600) mg/l (0,002 − 0,200) mg/l N-NO - 2 Spectrophotometric method PB-03 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14776
10 Water, water intended for human consumption Permanganate index Range: (0,50 − 10,0) mg/l Titrimetric method PN-EN ISO 8467:2001
11 Water, water intended for human consumption Total hardness Range: (60 − 500) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999
12 Water, water intended for human consumption Colour Range: (2 – 100) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012
13 Water, water intended for human consumption Chloride concentration Range: (5 – 500) mg/l Titrimetric method PN-ISO 9297:1994
14 Swimming pool water Sampling for chemical and physical testing Temperature of the water sample taken Range: (5 – 60) °C PN-ISO 5667-5:2017-10 IT-01/P.05 wyd. 8 z dnia 03.01.2022 r. PN-77/C-04584
15 Swimming pool water Free chlorine concentration Range: (0,05 − 6,0) mg/l Spectrophotometric method PB-14 wydanie 2 z dnia 27.11.2024 na podstawie testów 7-20/936220/Macherey-Nagel, 7-21/936221/Macherey-Nagel
16 Swimming pool water Total chlorine concentration Range: (0,05 − 6,0) mg/l Spectrophotometric method
17 Swimming pool water Combined chlorine (calculated)
18 Swimming pool water Oxidation-reduction (redox) potential ref. to Ag/AgCl 3,5 mol/l KCl Range: (200 – 1000) mV Potentiometric method PB-13 wydanie 2 z dnia 27.11.2024 r.
19 Swimming pool water Nitrate concentration Range: (0,9 − 40,0) mg/l (0,2 − 9,0) mg/l N-NO - 3 Spectrophotometric method PB-04 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14773
20 Swimming pool water pH Range: 4,0 − 9,0 Potentiometric method PN-EN ISO 10523:2012
21 Swimming pool water Turbidity Range: (0,10 − 10,0) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
22 Swimming pool water Permanganate index Range: (0,50 − 10,0) mg/l Titrimetric method PN-EN ISO 8467:2001
23 Water, wastewater Phosphate concentration Range: (0,15 – 153,0) mg/l (0,05 – 50,0) mg/l P-PO 3- 4 Spectrophotometric method PB-06 wydanie 4 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14848
24 Water, wastewater Total phosphorus concentration Range: (0,1 – 25,0) mg/l Spectrophotometric method PB-07 wydanie 4 z dnia 27.11.2024 r. na podstawie testów Merck nr 1.14687 i 1.14848
25 Water, wastewater Total nitrogen concentration Range: (1,0 – 100,0) mg/l Spectrophotometric method PB-08 wydanie 4 z dnia 27.11.2024 r. na podstawie testów Merck nr 1.14963 i 1.14773
26 Water, wastewater Biochemical oxygen demand − BOD 5 Range: (1 − 6000) mg/l Electrochemical method PN-EN ISO 5815-1:2019-12
27 Water, wastewater Biochemical oxygen demand − BOD 5 Range: (0,5 − 6) mg/l Electrochemical method PN-EN 1899-2:2002
28 Water, wastewater Chemical oxygen demand − COD-Cr Range: (8,0 − 3500) mg/l Spectrophotometric method PN-ISO 15705:2005
29 Water, wastewater Total suspended solids (TSS) Range: (2,0 − 5000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
30 Temperature of the collected water sample
31 Wastewater Sampling for chemical and physical testing Manual method Automatic method Temperature of the wastewater sample taken Range: (5 – 40) °C PN-ISO 5667-10:2021-11 PN-77/C-04584
32 Wastewater Ammonium ion concentration Range: (0,10 − 70,00) mg/l (0,08 − 57,56) mg/l N-NH + 4 Spectrophotometric method PB-05 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14752
33 Wastewater Nitrate concentration Range: (2,65 − 442) mg/l (0,6 − 100) mg/l N-NO - 3 Spectrophotometric method PB-04 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14773
34 Wastewater Nitrite concentration Range: (0,03 − 9,85) mg/l (0,01 − 3,00) mg/l N-NO - 2 Spectrophotometric method PB-03 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14776
35 Wastewater pH Range: 4,0 − 9,0 Potentiometric method PN-EN ISO 10523:2012
36 Wastewater Electrical conductivity Range: (100 – 3000) µS/cm Conductometric method PN-EN 27888:1999
37 Wastewater Chloride concentration Range: (5 – 500) mg/l Titrimetric method PN-ISO 9297:1994
38 Temperature of the collected wastewater sample
39 Water, swimming pool water, domestic hot water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
40 Water intended for human consumption Total count of microorganisms at 36 oC Plate method (pour plate) PN-EN ISO 6222:2004
41 Water intended for human consumption Total count of microorganisms at 22 oC Plate method (pour plate)
42 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
43 Water intended for human consumption Escherichia coli count Membrane filtration method
44 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2: 2004
45 Water intended for human consumption Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016-10
46 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
47 Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
48 Swimming pool water Total count of microorganisms at 36 oC Plate method (pour plate) PN-EN ISO 6222:2004
49 Swimming pool water, domestic hot water Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (BCYE medium) Procedure 7 (GVPC medium) PN-EN ISO 11731:2017-08 +Ap1:2019-12

Reference standards (31)

PB-01 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14761
PB-03 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14776
PB-04 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14773
PB-05 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14752
PB-06 wydanie 4 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14848
PB-07 wydanie 4 z dnia 27.11.2024 r. na podstawie testów Merck nr 1.14687 i 1.14848
PB-08 wydanie 4 z dnia 27.11.2024 r. na podstawie testów Merck nr 1.14963 i 1.14773
PB-13 wydanie 2 z dnia 27.11.2024 r.
PB-14 wydanie 2 z dnia 27.11.2024 na podstawie testów 7-20/936220/Macherey-Nagel, 7-21/936221/Macherey-Nagel
PB-14 wydanie 2 z dnia 27.11.2024 r. na podstawie testów 7-20/936220/Macherey-Nagel, 7-21/936221/Macherey-Nagel
PN-EN 1899-2:2002
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012
PN-EN ISO 7899-2: 2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10
PN-ISO 5667-5:2017-10 IT-01/P.05 wyd. 8 z dnia 03.01.2022 r. PN-77/C-04584
PN-ISO 6059:1999
PN-ISO 9297:1994