🇵🇱 ZAKŁAD WODOCIĄGÓW I KANALIZACJI PL
Water & wastewaterMicrobiology
ZAKŁAD WODOCIĄGÓW I KANALIZACJI is a laboratory accredited by PCA under number AB 1041 (Nowa Ruda, Poland). Its accreditation scope covers 49 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Swimming pool water, Water, water intended for human consumption, Water intended for human consumption, Wastewater.
At a glance
- Accreditation number: PCA AB 1041
- Methods in scope: 49
- Types of test objects: 8
- City: Nowa Ruda, Poland
- Accreditation number
- AB 1041
- Accreditation body
- PCA
- Address
- SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ, ul. Niepodległości 56, 57-400 Nowa Ruda, LABORATORIUM BADANIA WODY I ŚCIEKÓW, W ŚCINAWCE DOLNEJ
- City
- Nowa Ruda, Poland
What this laboratory tests (8)
- Swimming pool water — 12 methods
- Water, water intended for human consumption — 11 methods
- Water intended for human consumption — 8 methods
- Wastewater — 7 methods
- Water, wastewater — 7 methods
- Temperature — 2 methods
- Swimming pool water, domestic hot water — 1 method
- Water, swimming pool water, domestic hot water, water intended for human consumption — 1 method
Accreditation scope — test methods (49)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 2 | Water intended for human consumption | Free chlorine concentration Range: (0,05 − 6,0) mg/l Spectrophotometric method | PB-14 wydanie 2 z dnia 27.11.2024 r. na podstawie testów 7-20/936220/Macherey-Nagel, 7-21/936221/Macherey-Nagel | ||
| 3 | Water, water intended for human consumption | Ammonium ion concentration Range: (0,013 − 0,600) mg/l (0,010 − 0,500) mg/l N-NH + 4 Spectrophotometric method | PB-05 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14752 | ||
| 4 | Water, water intended for human consumption | Nitrate concentration Range: (0,9 – 60,0) mg/l (0,2 – 13,6) mg/l N-NO - 3 Spectrophotometric method | PB-04 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14773 | ||
| 5 | Water, water intended for human consumption | pH Range: 4,0 − 9,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 6 | Water, water intended for human consumption | Electrical conductivity Range: (100 – 3000) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 7 | Water, water intended for human consumption | Iron concentration Range: (0,005 − 1,000) mg/l Spectrophotometric method | PB-01 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14761 | ||
| 8 | Water, water intended for human consumption | Turbidity Range: (0,10 − 10,0) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 9 | Water, water intended for human consumption | Nitrite concentration Range: (0,007 − 0,600) mg/l (0,002 − 0,200) mg/l N-NO - 2 Spectrophotometric method | PB-03 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14776 | ||
| 10 | Water, water intended for human consumption | Permanganate index Range: (0,50 − 10,0) mg/l Titrimetric method | PN-EN ISO 8467:2001 | ||
| 11 | Water, water intended for human consumption | Total hardness Range: (60 − 500) mg/l CaCO 3 Titrimetric method | PN-ISO 6059:1999 | ||
| 12 | Water, water intended for human consumption | Colour Range: (2 – 100) mg/l Pt Spectrophotometric method | PN-EN ISO 7887:2012 | ||
| 13 | Water, water intended for human consumption | Chloride concentration Range: (5 – 500) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 14 | Swimming pool water | Sampling for chemical and physical testing Temperature of the water sample taken Range: (5 – 60) °C | PN-ISO 5667-5:2017-10 IT-01/P.05 wyd. 8 z dnia 03.01.2022 r. PN-77/C-04584 | ||
| 15 | Swimming pool water | Free chlorine concentration Range: (0,05 − 6,0) mg/l Spectrophotometric method | PB-14 wydanie 2 z dnia 27.11.2024 na podstawie testów 7-20/936220/Macherey-Nagel, 7-21/936221/Macherey-Nagel | ||
| 16 | Swimming pool water | Total chlorine concentration Range: (0,05 − 6,0) mg/l Spectrophotometric method | |||
| 17 | Swimming pool water | Combined chlorine (calculated) | |||
| 18 | Swimming pool water | Oxidation-reduction (redox) potential ref. to Ag/AgCl 3,5 mol/l KCl Range: (200 – 1000) mV Potentiometric method | PB-13 wydanie 2 z dnia 27.11.2024 r. | ||
| 19 | Swimming pool water | Nitrate concentration Range: (0,9 − 40,0) mg/l (0,2 − 9,0) mg/l N-NO - 3 Spectrophotometric method | PB-04 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14773 | ||
| 20 | Swimming pool water | pH Range: 4,0 − 9,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 21 | Swimming pool water | Turbidity Range: (0,10 − 10,0) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 22 | Swimming pool water | Permanganate index Range: (0,50 − 10,0) mg/l Titrimetric method | PN-EN ISO 8467:2001 | ||
| 23 | Water, wastewater | Phosphate concentration Range: (0,15 – 153,0) mg/l (0,05 – 50,0) mg/l P-PO 3- 4 Spectrophotometric method | PB-06 wydanie 4 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14848 | ||
| 24 | Water, wastewater | Total phosphorus concentration Range: (0,1 – 25,0) mg/l Spectrophotometric method | PB-07 wydanie 4 z dnia 27.11.2024 r. na podstawie testów Merck nr 1.14687 i 1.14848 | ||
| 25 | Water, wastewater | Total nitrogen concentration Range: (1,0 – 100,0) mg/l Spectrophotometric method | PB-08 wydanie 4 z dnia 27.11.2024 r. na podstawie testów Merck nr 1.14963 i 1.14773 | ||
| 26 | Water, wastewater | Biochemical oxygen demand − BOD 5 Range: (1 − 6000) mg/l Electrochemical method | PN-EN ISO 5815-1:2019-12 | ||
| 27 | Water, wastewater | Biochemical oxygen demand − BOD 5 Range: (0,5 − 6) mg/l Electrochemical method | PN-EN 1899-2:2002 | ||
| 28 | Water, wastewater | Chemical oxygen demand − COD-Cr Range: (8,0 − 3500) mg/l Spectrophotometric method | PN-ISO 15705:2005 | ||
| 29 | Water, wastewater | Total suspended solids (TSS) Range: (2,0 − 5000) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 30 | Temperature | of the collected water sample | |||
| 31 | Wastewater | Sampling for chemical and physical testing Manual method Automatic method Temperature of the wastewater sample taken Range: (5 – 40) °C | PN-ISO 5667-10:2021-11 PN-77/C-04584 | ||
| 32 | Wastewater | Ammonium ion concentration Range: (0,10 − 70,00) mg/l (0,08 − 57,56) mg/l N-NH + 4 Spectrophotometric method | PB-05 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14752 | ||
| 33 | Wastewater | Nitrate concentration Range: (2,65 − 442) mg/l (0,6 − 100) mg/l N-NO - 3 Spectrophotometric method | PB-04 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14773 | ||
| 34 | Wastewater | Nitrite concentration Range: (0,03 − 9,85) mg/l (0,01 − 3,00) mg/l N-NO - 2 Spectrophotometric method | PB-03 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14776 | ||
| 35 | Wastewater | pH Range: 4,0 − 9,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 36 | Wastewater | Electrical conductivity Range: (100 – 3000) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 37 | Wastewater | Chloride concentration Range: (5 – 500) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 38 | Temperature | of the collected wastewater sample | |||
| 39 | Water, swimming pool water, domestic hot water, water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 40 | Water intended for human consumption | Total count of microorganisms at 36 oC Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 41 | Water intended for human consumption | Total count of microorganisms at 22 oC Plate method (pour plate) | |||
| 42 | Water intended for human consumption | Coliform bacteria count Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | ||
| 43 | Water intended for human consumption | Escherichia coli count Membrane filtration method | |||
| 44 | Water intended for human consumption | Intestinal enterococci count Membrane filtration method | PN-EN ISO 7899-2: 2004 | ||
| 45 | Water intended for human consumption | Clostridium perfringens count including spores Membrane filtration method | PN-EN ISO 14189:2016-10 | ||
| 46 | Swimming pool water | Pseudomonas aeruginosa count Membrane filtration method | PN-EN ISO 16266:2009 | ||
| 47 | Swimming pool water | Escherichia coli count Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | ||
| 48 | Swimming pool water | Total count of microorganisms at 36 oC Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 49 | Swimming pool water, domestic hot water | Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (BCYE medium) Procedure 7 (GVPC medium) | PN-EN ISO 11731:2017-08 +Ap1:2019-12 | ||
Reference standards (31)
PB-01 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14761
PB-03 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14776
PB-04 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14773
PB-05 wydanie 6 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14752
PB-06 wydanie 4 z dnia 27.11.2024 r. na podstawie testu Merck nr 1.14848
PB-07 wydanie 4 z dnia 27.11.2024 r. na podstawie testów Merck nr 1.14687 i 1.14848
PB-08 wydanie 4 z dnia 27.11.2024 r. na podstawie testów Merck nr 1.14963 i 1.14773
PB-13 wydanie 2 z dnia 27.11.2024 r.
PB-14 wydanie 2 z dnia 27.11.2024 na podstawie testów 7-20/936220/Macherey-Nagel, 7-21/936221/Macherey-Nagel
PB-14 wydanie 2 z dnia 27.11.2024 r. na podstawie testów 7-20/936220/Macherey-Nagel, 7-21/936221/Macherey-Nagel
PN-EN 1899-2:2002
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012
PN-EN ISO 7899-2: 2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10
PN-ISO 5667-5:2017-10 IT-01/P.05 wyd. 8 z dnia 03.01.2022 r. PN-77/C-04584
PN-ISO 6059:1999
PN-ISO 9297:1994