🇵🇱 „SECURA” PL
EnvironmentConstruction
„SECURA” is a laboratory accredited by PCA under number AB 1039 (Gorzów Wielkopolski, Poland). Its accreditation scope covers 27 test methods in the following areas: Environment, Construction. Test objects include: Workplace environment − air, General environment − noise from installations, equipment and indus…, Machinery and equipment – noise, Rooms in residential, collective residence and public utility build….
At a glance
- Accreditation number: PCA AB 1039
- Methods in scope: 27
- Types of test objects: 11
- City: Gorzów Wielkopolski, Poland
- Accreditation number
- AB 1039
- Accreditation body
- PCA
- Address
- ZAKŁAD OCHRONY ŚRODOWISKA spółka cywilna, Tadeusz Jastrzębski, Piotr Michalak, ul. Urocza 11, 66-400 Gorzów Wielkopolski
- City
- Gorzów Wielkopolski, Poland
What this laboratory tests (11)
- Workplace environment − air — 6 methods
- General environment − noise from installations, equipment and industrial plants — 3 methods
- Machinery and equipment – noise — 2 methods
- Rooms in residential, collective residence and public utility buildings - noise — 2 methods
- Workplace environment - cold microclimate — 2 methods
- Workplace environment - hot microclimate — 2 methods
- Workplace environment - indoor electric lighting — 2 methods
- Workplace environment - moderate microclimate — 2 methods
- Workplace environment − hand-arm vibration — 2 methods
- Workplace environment − noise — 2 methods
- Workplace environment − whole-body vibration — 2 methods
Accreditation scope — test methods (27)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment − noise | A-weighted equivalent sound level A-weighted maximum sound level Range: (44 – 136) dB C-weighted peak sound level Range: (44 –137) dB Direct measurement method | PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt. 10 i 11 | ||
| 2 | Workplace environment − noise | Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated) | |||
| 3 | Workplace environment - moderate microclimate | Air temperature Range: (10 – 30) °C Blackened globe temperature Range: (10 – 30) °C Air humidity Range: (20 – 90) % Air velocity Range: (0,15 – 5,0) m/s Direct measurement method | PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04 | ||
| 4 | Workplace environment - moderate microclimate | PMV index PPD index (calculated) | |||
| 5 | Workplace environment - hot microclimate | Air temperature Range: (10 – 50) °C Natural wet bulb temperature Range: (10 – 50) °C Blackened globe temperature Range: (10 – 50) °C Air velocity Range: (0,15 – 5,0) m/s Direct measurement method | PN-EN ISO 7243:2018-01 PN-EN ISO 7243:2018-01/AP-2:2020- 04 | ||
| 6 | Workplace environment - hot microclimate | WBGT index WBGT eff index (calculated) | |||
| 7 | Workplace environment - cold microclimate | Air temperature Range: (-20 – 10) °C Blackened globe temperature Range: (-20 – 10) °C Air humidity Range: (20 – 90) % Air velocity Range: (0,15 – 5,0) m/s Direct measurement method | PN-EN ISO 11079:2008 | ||
| 8 | Workplace environment - cold microclimate | IREQ min index IREQ neutral index t wc index (calculated) | |||
| 9 | Workplace environment - indoor electric lighting | Illuminance Range: (5 – 5 000) lx Direct measurement method | PN-83/E-04040.03 | ||
| 10 | Workplace environment - indoor electric lighting | Illuminance uniformity (calculated) | |||
| 11 | Workplace environment − hand-arm vibration | Frequency-weighted effective vibration acceleration Range: (0,2 – 100) m/s2 Direct measurement method | PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004+A1:2015-11 | ||
| 12 | Workplace environment − hand-arm vibration | Daily exposure, expressed as the 8-hour energy-equivalent vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (a , a , a ). hwz hwy hwz Exposure lasting 30 minutes and less, expressed as the vector sum of the frequency-weighted RMS vibration accelerations determined for the three directional components (a , a , a ) hwz hwy hwz (calculated) | |||
| 13 | Workplace environment − whole-body vibration | Frequency-weighted effective vibration acceleration Range: (0,02 – 7,6) m/s2 Direct measurement method | PN-EN 14253+A1:2011 | ||
| 14 | Workplace environment − whole-body vibration | Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4a , hwz 1,4a , a ) hwy hwz Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1,4a , hwz 1,4a , a ) hwy hwz (calculated) | |||
| 15 | Workplace environment − air | Sampling for occupational exposure assessment to: - dust agents – inhalable fraction – respirable fraction - organic substances, including – inhalable fraction - inorganic substances, including – inhalable fraction – respirable fraction – thoracic fraction - metals their compounds, including – inhalable fraction – respirable fraction - asbestos – respirable fibres - man-made mineral fibres, excluding refractory ceramic fibres – respirable fibres Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | ||
| 16 | Workplace environment − air | Exposure index (calculated) | |||
| 17 | Workplace environment − air | Concentration of harmful dust agents - inhalable fraction: - Apatites and phosphorites - Portland cement - Titanium dioxide - Natural graphite - Synthetic graphite - Kaolin - Amorphous and synthetic silica - Wood dust - Flour dust - Dusts not classified according to toxicity - Organic dusts of animal and plant origin except wood and flour dust - Calcium sulphate (VI) (gypsum) - Carbon black - Man-made mineral fibres, except refractory ceramic fibres - Talc - Coal (hard, brown) - Magnesium calcium carbonate (dolomite) - Silicon carbide, non-fibrous Range: (0,32 – 13,6) mg/m3 Gravimetric method | PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08 | ||
| 18 | Workplace environment − air | Concentration of harmful dust agents- respirable fraction: - Apatites and phosphorites - Portland cement - Natural graphite - Amorphous and synthetic silica - Organic dusts of animal and plant origin except wood and flour dust - Diesel engine exhaust - Talc - Coal (hard, brown) Range: (0,08 – 7,31) mg/m3 Gravimetric method | PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08 | ||
| 19 | Workplace environment − air | Carbon monoxide concentration Range: (2,3 – 232) mg/m3 (2 – 200) ppm Electrochemical method | PB.03-1, wydanie 4 z 03.02.2025 r. | ||
| 20 | Workplace environment − air | Exposure indices (calculated) | |||
| 21 | General environment − noise from installations, equipment and industrial plants | A-weighted equivalent sound level, Range: (24 – 136) dB Direct measurement method | nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz.1706) PN-ISO 9613-2:2002 | ||
| 22 | General environment − noise from installations, equipment and industrial plants | A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated) | |||
| 23 | General environment − noise from installations, equipment and industrial plants | Calculation method | |||
| 24 | Machinery and equipment – noise | A-weighted equivalent sound level weighted with the A frequency characteristic Range: (24 – 136) dB Direct measurement method | PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem p. 8.4 | ||
| 25 | Machinery and equipment – noise | Sound power level (calculated) | |||
| 26 | Rooms in residential, collective residence and public utility buildings - noise | A-weighted equivalent sound level A-weighted maximum sound level Range: (24 – 136) dB Direct measurement method | PN-87/B-02156 | ||
| 27 | Rooms in residential, collective residence and public utility buildings - noise | A-weighted equivalent sound level for reference time T (calculated) | |||
Reference standards (15)
PB.03-1, wydanie 4 z 03.02.2025 r.
PN-83/E-04040.03
PN-87/B-02156
PN-EN 14253+A1:2011
PN-EN ISO 11079:2008
PN-EN ISO 3746:2011+Ap1:2017-09 z wyłączeniem p. 8.4
PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004+A1:2015-11
PN-EN ISO 7243:2018-01 PN-EN ISO 7243:2018-01/AP-2:2020- 04
PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04
PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt. 10 i 11
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08
enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz.1706) PN-ISO 9613-2:2002
nr 7