„ZIELONOGÓRSKIE WODOCIĄGI I KANALIZACJA” Sp. z o.o. is a laboratory accredited by PCA under number AB 1006 (Zielona Góra, Poland). Its accreditation scope covers 65 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Wastewater, Water (including swimming pool water), water intended for human con…, Water.

At a glance

  • Accreditation number: PCA AB 1006
  • Methods in scope: 65
  • Types of test objects: 6
  • City: Zielona Góra, Poland
Accreditation number
AB 1006
Accreditation body
PCA
Address
ul. Zjednoczenia 110 A, 65-120 Zielona Góra, LABORATORIUM BADANIA WÓD I ŚCIEKÓW, ul. Zawada-Kożuchowska 35
City
Zielona Góra, Poland

What this laboratory tests (6)

Accreditation scope — test methods (65)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water Sampling for chemical and physical testing (including sensory) Temperature of water/collected water sample Range: (2,0 – 30,0) °C PN-EN ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2 | PB-07
2 Water Total alkalinity Range: (0,4 – 20) mmol/l Titrimetric method PN-EN ISO 9963-1:2001+ Ap1:2004
3 Water Total suspended solids Range: (2,0 – 30) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
4 Water intended for human consumption Sampling for chemical and physical testing (including sensory) Temperature of water/collected water sample Range: (2,0 – 30,0) °C PN-ISO 5667-5:2017-10 PB-07 wydanie 03 z dnia 19.08.2024 r.
5 Water intended for human consumption Taste threshold number TFN Range: 1 Simplified paired method, non-forced choice PN-EN 1622:2006
6 Water intended for human consumption Threshold flavour number TFN Range: 1 – 16 Full method, paired, non-forced choice
7 Water intended for human consumption Chlorate concentration Range: (0,050 – 0,80) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-4:2022-08
8 Water intended for human consumption Chlorite concentration Range: (0,050 – 1,0) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-4:2022-08
9 Water, water intended for human consumption Threshold odour number TON Range: 1 Full method, paired, non-forced choice PN-EN 1622:2006
10 Water, water intended for human consumption Threshold odour number TON Range: 1 – 16 Simplified method, paired, non-forced choice
11 Water, water intended for human consumption Electrical conductivity Range: (147 – 5000) S/cm Conductometric method PN-EN 27888:1999
12 Water, water intended for human consumption Chloride concentration Range: (5 – 400) mg/l Titrimetric method PN-ISO 9297:1994
13 Water, water intended for human consumption Nitrate concentration Range: (0,5 – 50) mg/l Spectrophotometric method PN-82/C-04576.08
14 Water, water intended for human consumption Nitrite concentration Range: (0,005 – 0,800) mg/l Spectrophotometric method PN-EN 26777:1999
15 Water, water intended for human consumption Total calcium and magnesium concentration (total hardness) Range: (0,05 – 40) mmol/l (5 – 4000) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999
16 Water, water intended for human consumption Calcium concentration Range: (3,0 – 200) mg/l Titrimetric method PN-ISO 6058:1999
17 Water, water intended for human consumption Ammonium ion concentration Range: (0,05 – 2,50) mg/l Spectrophotometric method PB-11 wydanie 04 z dnia 04.09.2020 r. na podstawie metody HACH Nr 8038
18 Water, water intended for human consumption Manganese concentration Range: (0,020 – 1,0) mg/l Spectrophotometric method PN-92/C-04590/03
19 Water, water intended for human consumption Anion concentrations Range: Fluorides (0,05 – 5,0) mg/l Sulfates (2,5 – 250) mg/l Chlorides (2,5 – 250) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009
20 Water, water intended for human consumption Colour Range: (2,0 – 40) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015- 06 Metoda C
21 Water, water intended for human consumption Total organic carbon concentration Range: (0,5 – 20) mg/l Infrared range spectrometry method IR PN-EN 1484:1999
22 Water (including swimming pool water), water intended for human consumption pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012
23 Water (including swimming pool water), water intended for human consumption Turbidity Range: (0,1 – 20) NTU Nephelometric method PB-06 wydanie 05 z dnia 04.09.2020 r.
24 Water (including swimming pool water), water intended for human consumption Nitrate concentration Range (1,0 – 100) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009
25 Water (including swimming pool water), water intended for human consumption Iron concentration Range: (0,02 – 5,0) mg/l Spectrophotometric method PN-ISO 6332:2001 pkt. 7.2 PN-ISO 6332:2001/Ap1:2016-06
26 Water (including swimming pool water), water intended for human consumption Permanganate index Range: (0,5 – 12) mg/l Titrimetric method PN-EN ISO 8467:2001
27 Water (including swimming pool water), water intended for human consumption Free chlorine concentration Range: (0,05 – 3,5) mg/l Spectrophotometric method PB-02 wydanie 03 z dnia: 28 06.2024 r. na podstawie metody HANNA nr HI93701, HACH nr 9429000
28 Water (including swimming pool water), water intended for human consumption Total chlorine concentration Range: (0,05 – 3,5) mg/l Spectrophotometric method PB-02 wydanie 03 z dnia: 28 06.2024 r. na podstawie metody HANNA nr HI93711, HACH nr 9429100
29 Water (including swimming pool water), water intended for human consumption Combined chlorine concentration (calculated) PB-02 wydanie 03 z dnia 28.06.2024 r.
30 Water (including swimming pool water), water intended for human consumption Oxidation-reduction (redox) potential ref. to Ag/AgCl 3,5 mol/l KCl Range: (230 – 800) mV Potentiometric method PB-32 wydanie 01 z dnia 02.09.2019 r.
31 Wastewater Anion concentrations Range: Sulfates (2,5 – 250) mg/l Nitrates (1,0 – 100) mg/l Chlorides (2,5 – 250) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009
32 Water, water intended for human consumption Sampling for microbiological testing Temperature of water/of the water sample taken Range: (2,0 – 60,0) °C PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3; 4.4.4; 4.4.5; 4.4.6 PB-07 wydanie 03 z dnia 19.08.2024 r.
33 Water, water intended for human consumption Total count of microorganisms at 22˚C Plate method (pour plate) PN-EN ISO 6222:2004
34 Water, water intended for human consumption Total count of microorganisms at 36˚C Plate method (pour plate) PN-EN ISO 6222:2004
35 Water, water intended for human consumption Presence and number of coliform bacteria Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
36 Water, water intended for human consumption Presence and count of Escherichia coli Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
37 Water, water intended for human consumption Presence and count of enterococci (faecal streptococci) Membrane filtration method PN-EN ISO 7899-2:2004
38 Water, water intended for human consumption Presence and number of Clostridium perfringens bacteria including spores Membrane filtration method PN-EN ISO 14189:2016-10
39 Water, water intended for human consumption Presence and count of Pseudomonas aeruginosa bacteria Membrane filtration method PN-EN ISO 16266:2009
40 Water, water intended for human consumption Most probable number of coliform bacteria and Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
41 Swimming pool water Total count of microorganisms at 36˚C Plate method (pour plate) PN-EN ISO 6222:2004
42 Swimming pool water Presence and count of Escherichia coli Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
43 Swimming pool water Presence and count of Pseudomonas aeruginosa bacteria Membrane filtration method PN-EN ISO 16266:2009
44 Wastewater Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater/of the wastewater sample taken Range: (2,0 – 60,0) °C PN-ISO 5667-10:2021-11 PB-07 wydanie 03 z dnia 19.08.2024 r.
45 Wastewater Dissolved orthophosphate concentration Range: (0,05 – 4,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 p.4 +Ap1:2010+Ap2:2010
46 Wastewater pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012
47 Wastewater Total suspended solids Range: (2,0 – 1200) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
48 Wastewater Electrical conductivity Range: (147 – 5000) S/cm Conductometric method PN-EN 27888:1999
49 Wastewater Chemical oxygen demand - COD Range: (15 – 7000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005
50 Wastewater Ammonium ion concentration Range: (1,0 – 250) mg/l Titrimetric method PN-ISO 5664:2002
51 Wastewater Biochemical oxygen demand – BOD 5 Range: (3 – 3500) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12
52 Wastewater Total phosphorus concentration Range: (0,5 – 30) mg/l Spectrophotometric method PB-26 wydanie 02 z dnia 17.08.2020 r. na podstawie testu kuwetowego Merck Nr 1.14729.0001
53 Wastewater Total nitrogen concentration Range: (1,0 – 120) mg/l Spectrophotometric method PB-25 wydanie 02 z dnia 17.08.2020 r. na podstawie testu kuwetowego Merck Nr 1.14537.0001
54 Wastewater Nitrite concentration Range: (0,005 – 1,20) mg/l Spectrophotometric method PN-EN 26777:1999
55 Wastewater Chloride concentration Range: (5,0 – 1000) mg/l Titrimetric method PN-ISO 9297:1994
56 Wastewater Kjeldahl nitrogen concentration Range: (1,0 – 300) mg/l Titrimetric method PN-EN 25663:2001
57 Wastewater Anionic detergent concentration Range: (0,30 – 100) mg/l Spectrophotometric method PB-37 wydanie 01 z dnia 09.07.2024 r. na podstawie testu kuwetowego Merck Nr 1.02552.0001
58 Wastewater Element concentrations Range: Arsenic (0,005 – 0,500) mg/l Zinc (0,050 – 100) mg/l Chromium (0,005 – 1,00) mg/l Cadmium (0,0010 – 0,500) mg/l Copper (0,005 – 1,00) mg/l Nickel (0,005 – 1,00) mg/l Lead (0,005 – 1,00) mg/l Vanadium (0,005 – 0,500) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
59 Wastewater Total phosphorus concentration Range: (0,050 – 60,0) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
60 Wastewater Sulphate concentration Range: (10,0 – 600) mg/l Gravimetric method PN-EN ISO 9280:2002
61 Wastewater Concentration of substances extractable with petroleum ether Range: (10,0 – 300) mg/l Gravimetric method PB-35 wydanie 01 z dnia 11.08.2023 r.
62 Water Kjeldahl nitrogen concentration Range: (1,0 – 20,0) mg/l Titrimetric method PN-EN 25663:2001
63 Water Biochemical oxygen demand - BOD 5 Range: (0,50 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002
64 Water Total phosphorus concentration Range: (0,050 – 1,00) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
65 Water, water intended for human consumption Element concentrations Range: Boron (0,010 – 1,00) mg/l Zinc (0,010 – 1,00) mg/l Chromium (0,0010 – 0,050) mg/l Aluminium (0,010 – 1,00) mg/l Cadmium (0,0010 – 0,050) mg/l Copper (0,0010 – 0,200) mg/l Nickel (0,0030– 0,020) mg/l Lead (0,0030– 0,020) mg/l Sodium (1,00 – 260) mg/l Potassium (0,500 – 10,0) mg/l Manganese (0,010 – 1,00) mg/l Iron (0,010 – 10,0) mg/l Magnesium (1,00 – 125) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009

Reference standards (46)

PB-02 wydanie 03 z dnia 28.06.2024 r.
PB-02 wydanie 03 z dnia: 28 06.2024 r. na podstawie metody HANNA nr HI93701, HACH nr 9429000
PB-02 wydanie 03 z dnia: 28 06.2024 r. na podstawie metody HANNA nr HI93711, HACH nr 9429100
PB-06 wydanie 05 z dnia 04.09.2020 r.
PB-07
PB-11 wydanie 04 z dnia 04.09.2020 r. na podstawie metody HACH Nr 8038
PB-25 wydanie 02 z dnia 17.08.2020 r. na podstawie testu kuwetowego Merck Nr 1.14537.0001
PB-26 wydanie 02 z dnia 17.08.2020 r. na podstawie testu kuwetowego Merck Nr 1.14729.0001
PB-32 wydanie 01 z dnia 02.09.2019 r.
PB-35 wydanie 01 z dnia 11.08.2023 r.
PB-37 wydanie 01 z dnia 09.07.2024 r. na podstawie testu kuwetowego Merck Nr 1.02552.0001
PN-82/C-04576.08
PN-92/C-04590/03
PN-EN 1484:1999
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009
PN-EN ISO 10304-4:2022-08
PN-EN ISO 10523:2012
PN-EN ISO 11885:2009
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3; 4.4.4; 4.4.5; 4.4.6 PB-07 wydanie 03 z dnia 19.08.2024 r.
PN-EN ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p.4 +Ap1:2010+Ap2:2010
PN-EN ISO 7887:2012+Ap1:2015- 06 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9280:2002
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-EN ISO 9963-1:2001+ Ap1:2004
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PB-07 wydanie 03 z dnia 19.08.2024 r.
PN-ISO 5667-5:2017-10 PB-07 wydanie 03 z dnia 19.08.2024 r.
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001 pkt. 7.2 PN-ISO 6332:2001/Ap1:2016-06
PN-ISO 9297:1994