🇵🇱 SIEĆ BADAWCZA ŁUKASIEWICZ PL

PCA AB 054 • Kraków, Poland • 1102 methods

ConstructionEnvironmentMaterials & polymersWater & wastewaterPetrochemistry & fuels

SIEĆ BADAWCZA ŁUKASIEWICZ is a laboratory accredited by PCA under number AB 054 (Kraków, Poland). Its accreditation scope covers 1102 test methods in the following areas: Construction, Environment, Materials & polymers, Water & wastewater. Test objects include: Waste gases, Aggregates E, Water, Wastewater, Building lime E. Most frequently used techniques: Gravimetric method, Titrimetric method, Spectrophotometric method.

At a glance

  • Accreditation number: PCA AB 054
  • Methods in scope: 1102
  • Types of test objects: 250
  • Techniques used: 152
  • City: Kraków, Poland
Accreditation number
AB 054
Accreditation body
PCA
Address
– INSTYTUT CERAMIKI, I MATERIAŁÓW BUDOWLANYCH, ul. Cementowa 8, 31-983 Kraków
City
Kraków, Poland

What this laboratory tests (250)

Analytical techniques used (152)

Laboratory sections (9)

Laboratory locations

Accreditation scope — test methods (1102)

No. Test object Methodology / Parameters Technique Reference document
Centre for Fire Safety and Acoustics; Glass and Acoustics Research Group
1 Glass and glass products Numerical expression of colours
Range (380 - 780) nm
Spectrophotometric method PN-N-01252:1965 | DIN 5033:1992 cz.3
2 Safety building glass, toughened and laminated Resistance to impact by a bag PN-B-13083:1997
3 Toughened safety glass panes for railway applications Light transmittance
Range (380 - 780) nm
Spectrophotometric method PN-B-13059:1985 | PN-B-13153:1981
4 Toughened safety glass panes for railway applications Resistance to impact by a 227 g ball PN-B-13059:1985 | PN-B-13153:1981
5 Toughened safety glass panes for railway applications Resistance to impact by a bag of side and interior glazing
Range (0 - 500) g
Gravimetric method PN-B-13059:1985
6 Toughened safety glass panes for railway applications Crack pattern
Range (0 - 300) mm Linear measurements
PN-B-13059:1985 | PN-B-13153:1981
7 Glass bottles and jars Capacity
Range 5 I
Gravimetric method PN-O-79711:1989
8 Glass and glass products E Viscosity as a function of temperature
Range (lgη= 2 - 5) dPas temp. do 1500 °C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Viscometric method PN-ISO 7884-1 | PN-ISO 7884-2
9 Glass and glass products E Mean coefficient of linear thermal expansion
Range od 100 °C do temp. mięknięcia
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Dilatometric method for glass PB-BF-16
10 Building glass (building glazing) E Light transmittance
Range (380 - 780) nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Spectrophotometric method PN-EN 410 „N”
11 Building glass (building glazing) E Light reflection
Range (380 - 780) nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Spectrophotometric method PN-EN 410 „N”
12 Building glass (building glazing) E Total solar energy transmittance
Range (300 - 2500) nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Spectrophotometric method PN-EN 410 „N”
13 Building glass (building glazing) E UV transmittance
Range (280 - 380) nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Spectrophotometric method PN-EN 410 „N”
14 Building glass (building glazing) E Colour rendering
Range (380 - 780) nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Spectrophotometric method PN-EN 410 „N”
15 Building glass (building glazing) E Thermal transmittance U
Range (0 - 3) W/m2k
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Calculation method PN-EN 673 „N”
16 Building glass (building glazing) E Emissivity
Range (5 - 50) μm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Spectrophotometric method PN-EN 12898
17 Insulating glass units E Gas content in the interpane space
Range (0 - 100) %
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Chromatographic method PB-BF-07
18 Insulating glass units E Rate of gas loss from the cavity between panes
Range (0 - 10) μg/godz.
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Chromatographic method PN-EN 1279-3 | PB-BF-17
19 Insulating glass units E Adhesion of sealant to glass
elongation (0 - 50) % stress (0 - 0,5) MPa
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Instrumental method PN-EN 1279-4
20 Insulating glass units E Thermal transmittance U
Range (0 - 3) W/m2k
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Guarded hot plate method PN-EN 674
21 Insulating glass units E Thermal transmittance U
Range (0 - 3) W/m2k
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Calculation method PN-EN-673 „N”
22 Insulating glass units E Moisture penetration
Range (0 - 200) g Range (0 - 20) g
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Gravimetric method; Karl Fischer method PN-EN 1279-2 | PN-EN 1279-4 | PN-EN 1279-6 Zał. B p. B.4
23 Safety glazing for road transport vehicles E UV transmittance
Range (280 - 380) nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Spectrophotometric method ISO 9050 p. 3.6
24 Safety glazing for road transport vehicles E Light transmittance
Range (380 - 780) nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Spectrophotometric method Regulamin EKG ONZ NR 43 Zał. 3 p. 9.1
25 Safety glazing for road transport vehicles E Total solar energy transmittance
Range (300 - 2500) nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Spectrophotometric method ISO 9050 p. 3.5.3
26 Building glass, thermally toughened safety glass E Dimensions and tolerances
Range (0 - 5000) mm Linear measurements
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 12150-1
27 Building glass, thermally toughened safety glass E Character of the crack network
Range (0 - 300) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Visual method and linear measurements PN-EN 12150-1 „N”
28 Building glass, thermally toughened safety glass E Flexural strength
Range (0 - 400) N/mm2
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 1288-3 „N”
29 Building glass, thermally toughened safety glass E Resistance to pendulum impact
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 12600 „N”
30 Building glass, thermally toughened, heat soaked safety glass E Dimensions
Range (0 - 5000) mm Linear measurements
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 14179-1
31 Building glass, thermally toughened, heat soaked safety glass E Character of the crack network
Range (0 - 300) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Visual method and linear measurements PN-EN 14179-1 „N”
32 Building glass, thermally toughened, heat soaked safety glass E Flexural strength
Range (0 - 400) N/mm2
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN-1288-3 „N”
33 Building glass, thermally toughened, heat soaked safety glass E Resistance to pendulum impact
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN-12600 „N”
34 Heat strengthened building glass E Dimensions
Range (0 - 5000) mm Linear measurements
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 1863-1
35 Heat strengthened building glass E Character of the crack network
Range (0 - 300) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Visual method and linear measurements PN-EN 1863-1 „N”
36 Heat strengthened building glass E Flexural strength
Range (0 - 300) N/mm2
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Instrumental method PN-EN 1288-3 „N”
37 Laminated glass and laminated safety glass E Resistance to pendulum impact
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 12600 „N”
38 Laminated glass and laminated safety glass E Resistance to high temperature
Range 100 °C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN ISO 12543-2 i 3 | PN-EN ISO 12543-4
39 Laminated glass and laminated safety glass E Resistance to moisture
Range (0 - 50) °C (80 ± 5)% relative humidity
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN ISO 12543-2 i 3 | PN-EN ISO 12543-4
40 Laminated glass and laminated safety glass E Resistance to radiation
Range (900 ± 100) W/m2 Range (380 - 780) nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Spectrophotometric method PN-EN ISO 12543-2 i 3 | PN-EN ISO 12543-4
41 Laminated glass and laminated safety glass E Dimensions and finish of the edges
Range (0 - 5000) mm Linear measurements
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN ISO 12543-5 | PN-EN ISO 12543-6
42 Toughened safety glazing for, Railway applications E Secondary image formation, optical distortion
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 15152
43 Construction products: E - glazing - walls - external, internal doors Airborne sound insulation
Range of band centre frequencies 1/3 oct (50 - 5000) Hz
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN ISO 10140-1 „N” | PN-EN ISO 10140-2 | PN-EN ISO 10140-4 | PN-EN ISO 10140-5 | PN-EN 16703
44 Building materials. Sound-absorbing materials. Objects and equipment forming interior furnishings. Sound-absorbing structures - road traffic noise reducing devices - acoustic screens Sound absorption coefficient in a reverberation chamber
Frequency range (100 - 5000) Hz
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN ISO 354:2005 z wyłączeniem pkt. 7.3.1.
45 Protective glazing for buildings E Resistance to penetration by a ball with a mass of 4,11 kg.
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 356 „N”
46 Protective glazing for buildings E Resistance to impact with a hammer and an axe
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 356 „N”
47 Safety glazing for road transport vehicles E (toughened and laminated) Optical distortion
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Regulamin EKG ONZ nr 43 Zał. 3 p. 9.2
48 Safety glazing for road transport vehicles E (toughened and laminated) Secondary image separation
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Regulamin EKG ONZ nr 43 Zał. 3 p. 9.3
49 Safety glazing for road transport vehicles E (toughened and laminated) Character of the crack network
Range (0 - 300) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Visual method and linear measurements Regulamin EKG ONZ nr 43 Zał. 3 p. 1, Zał.4 p.2, Zał. 5 p. 2, Zał. 8 p. 4
50 Safety glazing for road transport vehicles E (toughened and laminated) Resistance to impact by a ball of 2260 g mass
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Regulamin EKG ONZ nr 43 Zał. 3 p. 2.2, Zał. 6 p. 4.2
51 Safety glazing for road transport vehicles E (toughened and laminated) Resistance to impact by a ball of 227g mass
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Regulamin EKG ONZ nr 43 Zał. 3 p. 2.1, Zał. 5 p. 3.1, Zał. 6 p. 4.3, Zał. 7 p. 3, Zał. 11 p. 3
52 Safety glazing for road transport vehicles E (toughened and laminated) Resistance to impact by a dummy
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Regulamin EKG ONZ nr 43 Zał.3 p.3.1, Zał. 4 p. 3, Zał. 6 p. 3, Zał. 7 p. 3, Zał. 10 p.3, Zał. 11p. 3, Zał. 12 p. 3
53 Safety glazing for road transport vehicles E (toughened and laminated) Light transmittance
Range (380 - 780) nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Spectrophotometric method Regulamin EKG ONZ nr 43 Zał.3 p. 9.1
54 Safety glazing for road transport vehicles E (toughened and laminated) Abrasion resistance of glass
Range (380 - 780) nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Spectrophotometric method Regulamin EKG ONZ nr 43 Zał. 3 p. 4, Zał. 6 p. 5.1, Zał. 7 p. 4.1, Zał. 9 p. 2
55 Safety glazing for road transport vehicles E (toughened and laminated) Resistance to high temperature
Range 100 °C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Regulamin EKG ONZ nr 43 Zał. 3 p. 5
56 Safety glazing for road transport vehicles E (toughened and laminated) Resistance to radiation
Range 1400 W/m2, (380 - 780) nm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Spectrophotometric method Regulamin EKG ONZ nr 43 Zał. 3 p. 6
57 Safety glazing for road transport vehicles E (toughened and laminated) Resistance to moisture
Range (0 - 52) °C (95 ± 4)% relative humidity
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Regulamin EKG ONZ nr 43 Zał. 3 p. 7
58 Glass bottles and jars E Resistance to thermal shock
Range różnica temperatur 80 °C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises
PN-EN ISO 7459
59 Shower enclosures E Impact resistance/fragmentation properties
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises
Visual and counting method PN-EN 14428
60 Shower enclosures E Resistance of plastic sheets to impact by a bag of 45 kg mass
Range (0 - 1500) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises
Method: linear measurements PN-EN 14428
61 Shower enclosures E Resistance to chemicals and staining
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises
Visual method PN-EN 14428
62 Shower enclosures E Resistance to wetting and drying cycles
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises
Visual method PN-EN 14428
63 Shower enclosures E Reliability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises
PN-EN 14428
64 Shower enclosures E Stability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises
PN-EN 14428
65 Shower enclosures E Cabin tightness
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises
Visual method PN-EN 14428
66 Non-loadbearing walls E Fire integrity, fire insulation
flame stability ignition of the cotton pad holes and cracks mean temperature rise maximum temperature rise deflection
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises
PN-EN 1363-1 | PN-EN 1364-1
Centre for Fire Safety and Acoustics; Construction Chemistry and Fire Safety Research Group
67 External walls E Temperature value at the measuring points on the lines L1 and L2, Burning or smouldering on the lines L1 and L2, Occurrence of burning waste, Burning after the time of the test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-B-02867 BS 8414
68 Construction products excluding floors E Heat release:
FIGRA, THR 600s Smoke production: SMOGRA, TSP600s Lateral flame spread: LFS Dripping and falling off under the influence of fire
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 13823 „N”
69 Floorings and floor coverings E Critical heat flux, Heat flux at 30 minutes, Smoke emission, Flame spread distance, Flame extinguishment time
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN ISO 9239-1 „N”
70 External thermal insulation composite systems Resistance to hard body impact
Range (3 - 10) J
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-B-10027:1993
71 Adhesive and rendering compounds, adhesive and rendering mortars for external thermal insulation systems Bulk density
Range (1,0 - 3,0) g/cm3
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Gravimetric method PN-B-04500:1985 p.3.5
72 Tile adhesives Tensile strength
Force range (0,1 - 15) kN
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: pull-off PN-EN 1348:2008 „N”
73 Tile adhesives Slip
Range (0 - 20,0) mm
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 1308:2008
74 Tile adhesives Open time
Force range (0,1 - 15) kN
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: pull-off PN-EN 1346:2008
75 Tile adhesives Transverse deformation
Range (0 - 20,0) mm
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 12002:2010
76 Tile adhesives Determination of shear strength
Force range (0,05 – 12) kN
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 1324:2008 | PN-EN 12003:2010
77 Ceramic tiles Tensile strength
Force range (0,1 - 15) kN
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: pull-off PN-EN 1348:2008
78 Ceramic tiles Determination of shear strength
Force range (0,05 - 12) kN
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 1324:2008 | PN-EN 12003:2010
79 Non-loadbearing walls Fire resistance
Fire integrity, fire insulation flame stability ignition of the cotton pad holes and cracks mean temperature rise maximum temperature rise deflection
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 1364-1:2015-08 „N” | PN-EN 1364-1:2001 „N” | PN-EN 1363-1:2001 | PN-EN 1363-1:2012 | PN-EN 1363-1:2020-07 | PN-EN 1363-2:2001 z wył. P.7
80 Loadbearing walls Loadbearing capacity R, integrity, insulation, radiation, resistance to mechanical impact
deformation C deformation rate dC/dt flame persistence holes and cracks ignition of the cotton wool pad mean temperature rise maximum temperature rise irradiance effect of mechanical action deformation
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 1365-1:2013-08 „N” | PN-EN 1365-1:2001 „N” | PN-EN 1363-1:2012 | PN-EN 1363-1:2020-07 | PN-EN 1363-1:2001 z wył. P.7
81 Fire doors and shutters Fire resistance
Fire resistance fire insulation, min fire integrity, min flame stability irradiance at a single point
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 1634-1+A1:2018-03 „N” | PN-EN 1634-1+A1:2009 „N” | PN-EN 1363-1:2001 | PN-EN 1363-1:2012 | PN-EN 1363-1:2020-07 | PN-EN 1363-1:2001 z wył. P.7
82 Gypsum binders E Grading
Range (0 - 100,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Sieve analysis method PN-EN 13279-2
83 Gypsum binders E Water : binder ratio
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Pouring method PN-EN 13279-2
84 Gypsum binders E Setting time
Range (1 - 100) min.
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Knife method PN-EN 13279-2
85 Gypsum binders and gypsum mortars (plasters, skim coats, fillers, gypsum filling compounds) E Flexural strength
Force range (0,2 - 10) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 13279-2
86 Gypsum binders and gypsum mortars (plasters, skim coats, fillers, gypsum filling compounds) E Compressive strength
Force range (0,2 – 200) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 13279-2
87 Gypsum binders and gypsum mortars (plasters, skim coats, fillers, gypsum filling compounds) E Surface hardness
Range (2,0 - 30,0) N/mm2
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 13279-2
88 Gypsum mortars (plasters, skim coats, fillers, gypsum filling compounds) E Setting time
Range (3 - 480) min.
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Vicat method PN-EN 13279-2
89 Gypsum mortars (plasters, skim coats, fillers, gypsum filling compounds) E Grading
Range (0 - 100,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Sieve analysis method PN-EN 13279-2
90 Gypsum mortars (plasters, skim coats, fillers, gypsum filling compounds) E Water : binder ratio
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flow table method PN-EN 13279-2
91 Gypsum mortars (plasters, skim coats, fillers, gypsum filling compounds) E Adhesion to the substrate
Force range (0,1 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: pull-off PN-EN 13279-2
92 Jointing materials for gypsum plasterboards E Particle size distribution
Range (0 -100)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Sieve analysis method PN-EN 13963
93 Jointing materials for gypsum plasterboards E Setting time
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Vicat method PN-EN 13963
94 Jointing materials for gypsum plasterboards E No cracks
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 13963
95 Jointing materials for gypsum plasterboards E Adhesion/cohesion
Force range (0,1 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Pull-off method PN-EN 13963
96 Jointing materials for gypsum plasterboards E Flexural strength
Range (0,05 - 5) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Stretching method PN-EN 13963
97 Jointing materials for gypsum plasterboards E Flexural strength
Range (0,05 - 2) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Bending method PN-EN 13963
98 Gypsum adhesives for gypsum boards E Adhesion to the substrate
Force range (0,1 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: pull-off PN-EN 12860
99 Ceramic tiles E Tensile strength
Force range (0,1 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: pull-off EN 12004-2
100 Ceramic tiles E Determination of shear strength
Force range (0,05 - 12) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
EN 12004-2
101 Tile adhesives E Tensile strength
Force range (0,1 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: pull-off EN 12004-2
102 Tile adhesives E Slip
Range (0 - 20,0) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
EN 12004-2
103 Tile adhesives E Open time
Force range (0,1 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: pull-off EN 12004-2
104 Tile adhesives E Transverse deformation
Range (0 - 20,0) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
EN 12004-2
105 Tile adhesives E Determination of shear strength
Force range (0,05 - 12) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
EN 12004-2
106 Thermal insulation materials E Short-term water absorption by partial immersion of the specimen
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Gravimetric method PN-EN 1609 „N” | PN-EN ISO 29767
107 Thermal insulation materials E Water absorption by long-term immersion of the specimen
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Gravimetric method PN-EN 12087 „N” | PN-EN ISO 16535
108 Thermal insulation materials E Compressive strength, Range up to (0,025 - 10) kN compression test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 826 „N” | PN-EN ISO 29469
109 Thermal insulation materials E Tensile strength
Range (0,025 - 10) kN tensile test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 1607
110 Thermal insulation materials E Behaviour in bending
Range (0,025 - 10) kN Bend test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 12089
111 Thermal insulation materials E Water vapour transmission
Range (0 - 10) m
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Gravimetric method PN-EN 12086
112 Thermal insulation materials E Dimensions (length, width)
Range (do 2000) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 822 | PN-EN ISO 29465
113 Thermal insulation materials E Thickness
Range (0,0 - 300) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 823 | PN-EN ISO 29466
114 Thermal insulation materials E Squareness
Range (0,05 - 10) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 824
115 Thermal insulation materials E Flatness
Range (0,05 - 10) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 825 | PN-EN ISO 29468
116 Priming solutions, façade paints for external thermal insulation systems E Density
Range (1,0 - 2,5) g/cm3
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Pycnometric method PN-EN ISO 2811-1 ETAG 004 Europejskie Dokumenty Oceny
117 Priming solutions, façade paints for external thermal insulation systems E External appearance of the product as supplied
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN ISO 1513
118 Adhesive and rendering mortars for external thermal insulation systems E Bulk density
Range (0,5 - 2,5) g/cm3
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Gravimetric method PN-EN 1097-3
119 Adhesive and rendering compounds, adhesive and rendering mortars for external thermal insulation systems E Bulk density
Range (1,0 - 3,0) g/cm3
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Gravimetric method ETAG 004 Europejskie Dokumenty Oceny
120 Adhesive mortars and compounds for external thermal insulation systems E Adhesion to the substrate
Force range (0,1 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: pull-off ETAG 004 Europejskie Dokumenty Oceny
121 Adhesive mortars and compounds for external thermal insulation systems E Adhesion to the thermal insulation product
Force range (0,025 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: pull-off ETAG 004 Europejskie Dokumenty Oceny
122 Adhesive mortars and compounds for external thermal insulation systems E Shrinkage
Range (0,1 - 1,5) mm/m
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Graff-Kaufman method ETAG 004 Europejskie Dokumenty Oceny
123 Adhesive mortars and compounds for external thermal insulation systems E Static modulus of elasticity,
tear strength Force range (0,05 - 1) kN elongation at fracture Range (0,1 - 25) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
ETAG 004 Europejskie Dokumenty Oceny
124 Adhesive mortars and compounds for external thermal insulation systems E Apparent density
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
ETAG 004 Europejskie Dokumenty Oceny
125 External thermal insulation composite systems E Watertightness
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
ETAG 004 Europejskie Dokumenty Oceny
126 External thermal insulation composite systems E Water absorption
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method ETAG 004 Europejskie Dokumenty Oceny
127 External thermal insulation composite systems E Resistance to hard body impact
Range (3 - 10) J
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
ETAG 004 Europejskie Dokumenty Oceny
128 External thermal insulation composite systems E Resistance to puncture
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: Perfotest ETAG 004 Europejskie Dokumenty Oceny
129 External thermal insulation composite systems E Water vapour permeability (water vapour diffusion resistance)
Range (0 - 3,0) m
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Free films method – gravimetric method ETAG 004 Europejskie Dokumenty Oceny | PN-EN ISO 7783
130 External thermal insulation composite systems E Water vapour transmission properties
Range (0 - 3,0) m
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 12086
131 External thermal insulation composite systems E Adhesion of the reinforced layer to the thermal insulation product
Force range (0,025 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: pull-off ETAG 004 Europejskie Dokumenty Oceny
132 External thermal insulation composite systems E Adhesion after ageing
Force range (0,025 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: pull-off ETAG 004 Europejskie Dokumenty Oceny
133 Fasteners for fixing thermal insulation E Resistance to wind load consisting in pull-through of fasteners through the thermal insulation product, Range up to 10 kN tensile test
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
ETAG 004 Europejskie Dokumenty Oceny
134 Gypsum adhesives for composite panels used in thermal and acoustic insulation and for gypsum plasterboards E Usage time
Range (3 - 360) min.
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 14496
135 Gypsum adhesives for composite panels used in thermal and acoustic insulation and for gypsum plasterboards E Adhesion to expanded polystyrene
Force range (0,1 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: pull-off PN-EN 14496
136 Reinforcing meshes/fabrics for thermal insulation systems E Mass per unit area
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
ETAG 004
137 Reinforcing meshes/fabrics for thermal insulation systems E Size (dimensions) of mesh and number of fibres
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
ETAG 004
138 Reinforcing meshes/fabrics for thermal insulation systems E Breaking strength and elongation
Range (2 - 100) N/mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
ETAG 004
139 Reinforcing meshes/fabrics for thermal insulation systems E Mesh dimensions
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Europejskie Dokumenty Oceny
140 Reinforcing meshes/fabrics for thermal insulation systems E Mesh width
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Europejskie Dokumenty Oceny
141 Reinforcing meshes/fabrics for thermal insulation systems E Mass per unit area
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Europejskie Dokumenty Oceny
142 Sealants E Initial adhesion
Force range (0,1 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: pull-off PN-EN 14891
143 Sealants E Adhesion after contact with water
Force range (0,1 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: pull-off PN-EN 14891 p.A.6.4
144 Sealants E Adhesion after thermal ageing
Force range (0,1 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: pull-off PN-EN 14891
145 Sealants E Adhesion after freeze-thaw cycles
Force range (0,1 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: pull-off PN-EN 14891
146 Sealants E Adhesion after exposure to lime water
Force range (0,1 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: pull-off PN-EN 14891
147 Sealants E Adhesion after exposure to chlorinated water
Force range (0,1 - 15) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: pull-off PN-EN 14891 p. A.6.8
148 Sealants E Crack bridging ability under standardized conditions
Range (0,1 - 25,0) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 14891
149 Construction products (e.g. insulating materials, flooring materials, adhesives, plasters, mortars, compounds, etc.) E Flaming combustion time, Relative mass loss, Temperature rise
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN ISO 1182 „N”
150 Construction products E Occurrence of inflammation, Spread of flames, Occurrence of flaming droplets and solid debris causing inflammation of the filter paper
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN ISO 11925-2 „N”
Centre for Sustainable Construction; Laboratory of Building Raw Materials and Binders
151 Cement constituents Calcium oxide CaO content
Range (0,01 - 65,0)%
Titrimetric method PN-H-04156-07:1981
152 Cement constituents Magnesium oxide MgO content
Range (0,02 - 20,0)%
Titrimetric method PN-H-04156-08:1981
153 Cement constituents Manganese content
Range (0,005 - 2,0)%
Spectrophotometric method PN-G-04528-00:1977 | PN-G-04528-09:1979
154 Cement constituents Phosphorus pentoxide P2O5 content
Range (0,001 - 20,0)%
Spectrophotometric method PN-G-04528-11:1986 | PN-H-04159-07:1983
155 Limestone Calcium oxide CaO content
Range (0,01 - 65,0)%
Titrimetric method PN-H-04156-07:1981
156 Limestone Magnesium oxide MgO content
Range (0,02 - 20,0)%
Titrimetric method PN-H-04156-08:1981
157 Limestone Manganese content
Range (0,005 - 2,0)%
Spectrophotometric method PN-G-04528-00:1977 | PN-G-04528-09:1979
158 Limestone Phosphorus pentoxide P2O5 content
Range (0,001 - 20,0)%
Spectrophotometric method PN-G-04528-11:1986 | PN-H-04159-07:1983
159 Ashes Loss on ignition content
Range (0,05 - 40,0)%
Gravimetric method PN-G-04528-02:1977
160 Ashes Sulphuric anhydride SO3 content
Range (0,01 - 15,0) %
Gravimetric method PN-G-04528-12:1977
161 Ashes Silicon dioxide SiO2 content
Range (0,10 - 80,0)% Range (0,005 - 0,50)%
Gravimetric method; Spectrophotometric method PN-G-04528-03:1977
162 Ashes Iron (III) oxide Fe2O3 content
Range (0,15 - 25,0)% Range (0,005 - 0,50)%
Titrimetric method; Spectrophotometric method PN-G-04528-05:1978
163 Ashes Aluminium oxide Al2O3 content
Range (0,05 - 30,0)%
Titrimetric method PN-G-04528-04:1977
164 Ashes Calcium oxide CaO content
Range (0,01 - 25,0)%
Titrimetric method PN-G-04528-06:1977
165 Ashes Magnesium oxide MgO content
Range (0,02 - 10,0)%
Titrimetric method PN-G-04528-07:1977
166 Ashes Manganese content
Range (0,005 - 5,0)%
Spectrophotometric method PN-G-04528-09:1979
167 Ashes Phosphorus pentoxide P2O5 content
Range (0,001 - 20,0)%
Spectrophotometric method PN-G-04528-11:1986
168 Glass Silicon dioxide SiO2 content
Range (5,0 - 95,0)%
Gravimetric and spectrophotometric method PN-B-13160:1985
169 Glass Barium oxide content BaO
Range (0,2 - 5,0)%
Gravimetric method PN-B-13160:1985
170 Glass Aluminium oxide Al2O3 content
Range (0,2 - 15,0)%
Titrimetric method PN-B-13160:1985
171 Glass Calcium oxide CaO content
Range (0,5 - 15,0)%
Titrimetric method PN-B-13160:1985
172 Glass Magnesium oxide MgO content
Range (0,3 - 10)%
Titrimetric method PN-B-13160:1985
173 Glass Iron oxide Fe2O3 content
Range (0,01 - 0,5)%
Spectrophotometric method PN-B-13160:1985
174 Glass Titanium oxide TiO2 content
Range (0,005 - 0,1)%
Spectrophotometric method PN-B-13160:1985
175 Glass Boron oxide content B2O3
Range (0,5 - 20,0)%
Titrimetric method PN-B-13160:1985
176 Glass Lead oxide content PbO
Range (0,5 - 30,0)%
Titrimetric method PN-B-13160:1985
177 Glass Zinc oxide content ZnO
Range (0,5 - 5,0)%
Titrimetric method PN-B-13160:1985
178 Glass Alkali content Na2O and K2O
Range (0,02 - 20,0)% Range (0,02 - 20,0)%
Flame photometry method; Flame atomic absorption spectrometry FAAS PN-B-13160:1985
179 Glass Sulphuric anhydride SO3 content
Range (0,05 - 2,0)%
Gravimetric method PN-B-13160:1985
180 Glass Loss on ignition content
Range (0,05 - 1,0)%
Gravimetric method PN-B-13160:1985
181 Glass sand Moisture content
Range (0,1 - 20,0)%
Gravimetric method BN-80/6811-01
182 Glass sand Loss on ignition content
Range (0,005 - 3,0)%
Gravimetric method BN-80/6811-01
183 Glass sand Silicon dioxide SiO2 content
Range (90,0 - 100,0)%
Gravimetric method BN-80/6811-01
184 Glass sand Titanium oxide TiO2 content
Range (0,002 - 0,2)%
Spectrophotometric method BN-80/6811-01
185 Glass sand Iron oxide Fe2O3 content
Range (0,005 - 0,2)%
Spectrophotometric method BN-80/6811-01
186 Glass sand Aluminium oxide Al2O3 content
Range (0,5 - 6,0)% Range (0,001 - 0,5)%
Titrimetric method; Spectrophotometric method BN-80/6811-01
187 Glass sand Calcium oxide CaO content
Range (0,2 - 2,0)%
Titrimetric method BN-80/6811-01
188 Glass sand Alkali content Na2O and K2O
Range (0,002 - 2,0)%
Flame photometry method BN-80/6811-01
189 Glass sand Sulphuric anhydride SO3 content
Range (0,01 - 1,0)%
Gravimetric method BN-80/6811-01
190 Kaolins and clays Loss on ignition content
Range (0,05 - 5,0)%
Gravimetric method, BN-85/7011-23
191 Kaolins and clays Silicon dioxide SiO2 content
Range (0,05 - 80,0)%
Gravimetric and spectrophotometric method BN-85/7011-23
192 Kaolins and clays Aluminium oxide Al2O3 content
Range (0,5 - 30,0)%
Titrimetric method BN-85/7011-23
193 Kaolins and clays Iron oxide Fe2O3 content
Range (0,005 - 1,0)%
Spectrophotometric method, Range (1,0 - 20,0)%; Titrimetric method BN-85/7011-23
194 Kaolins and clays Titanium oxide TiO2 content
Range (0,001 - 1,0)%
Spectrophotometric method BN-85/7011-23
195 Kaolins and clays Calcium oxide CaO content
Range (0,5 - 25,0)%
Titrimetric method BN-85/7011-23
196 Kaolins and clays Magnesium oxide MgO content
Range (0,5 - 25,0)%
Titrimetric method BN-85/7011-23
197 Kaolins and clays Alkali content Na2O and K2O
Range (0,05 - 15,0)%
Flame photometry method and flame atomic absorption spectrometry method FAAS BN-85/7011-23
198 Kaolins and clays Sulphuric anhydride SO3 content
Range (0,2 - 5,0)%
Gravimetric method BN-85/7011-23
199 Magnesites and dolomites Loss on ignition content
Range (1,0 - 52,0)%
Gravimetric method PN-H-04156-01:1981
200 Magnesites and dolomites Silicon dioxide SiO2 content
Range (1,0 - 25,0)%
Gravimetric method PN-H-04156-02:1992
201 Magnesites and dolomites Iron oxide Fe2O3 content
Range (0,01 - 2,5)% Range (2,0 - 10,0)%
Spectrophotometric method; Titrimetric method PN-H-04156-03:1992
202 Magnesites and dolomites Aluminium oxide Al2O3 content
Range (1,0 - 5,0)%
Titrimetric method PN-H-04156-04:1981
203 Magnesites and dolomites Calcium oxide CaO content
Range (0,5 - 60,0)%
Titrimetric method PN-H-04156-07:1981
204 Magnesites and dolomites Magnesium oxide MgO content
Range (15,0 - 99,0)%
Titrimetric method PN-H-04156-08:1981
205 Magnesites and dolomites Alkali content Na2O and K2O
Range (0,04 - 2,8)%
Flame photometry method PN-H-04156-09:1981
206 Cements (common cements, special cements and others) E Compressive strength
Force range (2,4 - 240,0) kN Flexural strength Force range (0,2 - 10,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 196-1
207 Cements (common cements, special cements and others) E Standard consistence
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 196-3
208 Cements (common cements, special cements and others) E Setting times
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 196-3
209 Cements (common cements, special cements and others) E Soundness
Le Chatelier
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a ring PN-EN 196-3
210 Cements (common cements, special cements and others) E Density
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Le Chatelier flask, using a helium pycnometer PB/LP-15
211 Cements (common cements, special cements and others) E Specific surface area
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: air permeability (Blaine) PN-EN 196-6
212 Cements (common cements, special cements and others) E Degree of grinding
Range (0,063 - 1,00) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: sieve PN-EN 196-6 | PN ISO 2591-1
213 Cements (common cements, special cements and others) E Air content in mortars
Range (0 - 25)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a pressure apparatus PN-EN 413-2
214 Cements (common cements, special cements and others) E Shrinkage
Range (0,00 - 5,00) mm/m Kauffman
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Graff apparatus PB/LP-20
215 Cements (common cements, special cements and others) E Bulk density
Range (0,1 - 5,0) kg/dm3
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 459-2
216 Cements (common cements, special cements and others) E Sampling
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 196-7
217 Calcium aluminate cements E Compressive strength
Force range (2,4 - 240,0) kN Flexural strength Force range (0,2 - 10,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 14647 | PN-EN 196-1
218 Calcium aluminate cements E Consistency
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 14647 | PN-EN 196-3
219 Calcium aluminate cements E Setting times
Range (10 - 2000) min.
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 14647 | PN-EN 196-3
220 Calcium aluminate cements E Density
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Le Chatelier flask, using a helium pycnometer PB/LP-15
221 Calcium aluminate cements E Specific surface area
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: air permeability (Blaine) PN-EN 196-6
222 Calcium aluminate cements E Fineness,
Range (0,063 - 1,00) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: sieve PN-EN 196-6 | PN ISO 2591-1
223 Calcium aluminate cements E Sampling
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 196-7
224 Masonry cements E Compressive strength
Force range (2,4 - 130,0) kN Flexural strength Force range (0,2 - 5,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 413-1 | PN-EN 196-1
225 Masonry cements E Standard consistence
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 413-2 | PN-EN 196-3
226 Masonry cements E Setting times
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 413-2 | PN-EN 196-3
227 Masonry cements E Soundness
Le Chatelier
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a ring PN-EN 196-3
228 Masonry cements E Density
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Le Chatelier flask, using a helium pycnometer PB/LP-15
229 Masonry cements E Specific surface area
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: air permeability (Blaine) PN-EN 196-6
230 Masonry cements E Consistence of standard mortar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a plunger apparatus using a flow table PN-EN 413-2
231 Masonry cements E Water retention
Range (0,0 - 100,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using filter paper PN-EN 413-2
232 Masonry cements E Sampling
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 196-7
233 Masonry cements E Air content
Range (0,1 - 25,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: pressure PN-EN 413-2
234 Masonry cements E Fineness, Fraction above 0,09 mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: sieve PN-EN 413-1 | PN-EN 196-6 | PN ISO 2591-1
235 Building lime E Compressive strength
Force range (2,4 - 50,0) kN Flexural strength Force range (0,2 - 4,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 459-2 | PN-EN 196-1
236 Building lime E Degree of grinding
Range (0,063 - 1,00) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: sieve PN-EN 196-6 | PN ISO 2591-1 | PN-EN 459-2
237 Building lime E Bulk density
Range (0,1 - 5,0) kg/dm3
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 459-2
238 Building lime E Soundness
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: based on changes in the dimensions of the pellet PN-EN 459-2
239 Building lime E Soundness
Le Chatelier
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a ring PN-EN 459-2 | PN-EN 196-3
240 Building lime E Soundness
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: based on observation of the cake surface; Method: based on observation of the disc surface PN-EN 459-2
241 Building lime E Consistency
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 459-2
242 Building lime E Setting times
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 459-2
243 Building lime E Reactivity
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a Dewar vessel PN-EN 459-2
244 Building lime E Capacity
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using an extinguishing container PN-EN 459-2
245 Building lime E Consistence of standard mortar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a flow table and a plunger apparatus PN-EN 459-2
246 Building lime E Water retention
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using filter paper PN-EN 459-2
247 Building lime E Air content
Range (0,1 - 25,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: pressure PN-EN 459-2
248 Building lime E Density
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Le Chatelier flask, using a helium pycnometer PB/LP-15
249 Siliceous fly ash E Compressive strength (for the activity index)
Force range (2,4 - 240,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 450-1 | PN-EN 196-1
250 Siliceous fly ash E Flexural strength
Force range (0,2 - 10,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 196-1
251 Siliceous fly ash E Standard consistence
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 450-1 | PN-EN 196-3
252 Siliceous fly ash E Setting times
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 450-1 | PN-EN 196-3
253 Siliceous fly ash E Soundness
Le Chatelier
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a ring PN-EN 450-1 | PN-EN 196-3
254 Siliceous fly ash E Density
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Le Chatelier flask, using a helium pycnometer PB/LP-15
255 Siliceous fly ash E Water demand
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a flow table PN-EN 450-1 Załącznik B
256 Siliceous fly ash E Fineness (fineness of grind), Fraction above 0,045 mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: sieve PN-EN 451-2
257 Siliceous fly ash E Sampling
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 196-7
258 Fillers (ash, slag-ash, cement, sand) E Particle density
Range (1,5 - 4,0) Mg/m3
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: pycnometric PN-EN 1097-7
259 Calcareous fly ash E Fineness, Fraction above 0,04 mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: sieve PN-EN 197-1
260 Calcareous fly ash E Compressive strength
Force range (1,0 - 30,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 196-1 | PN-EN 197-1
261 Calcareous fly ash E Flexural strength
Force range (0,2 - 10,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 196-1
262 Calcareous fly ash E Standard consistence
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 196-3 | PN-EN 197-1
263 Calcareous fly ash E Soundness
Le Chatelier
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a ring PN-EN 196-3 | PN-EN 197-1
264 Calcareous fly ash E Density
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Le Chatelier flask, using a helium pycnometer PB/LP-15
265 Slags E Compressive strength
Force range (2,4 - 240,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 15167-1 | PN-EN 196-1
266 Slags E Flexural strength
Force range (0,2 - 10,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 196-1
267 Slags E Consistency
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 15167-1 | PN-EN 196-3
268 Slags E Setting times
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 15167-1 | PN-EN 196-3
269 Slags E Density
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Le Chatelier flask, using a helium pycnometer PB/LP-15
270 Slags E Specific surface area
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: air permeability (Blaine) PN-EN 196-6 | PN-EN 15167-1
271 Slags E Degree of grinding
Range (0,063 - 1,00) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: sieve PN-EN 196-6 | PN ISO 2591-1
272 Slags E Sampling
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 196-7
273 Silica fume E Compressive strength (for the activity index)
Force range (2,4 - 240,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 13263-1 | PN-EN 196-1 | PN-EN 413-2
274 Silica fume E Flexural strength
Force range (0,2 - 10,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 196-1
275 Silica fume E Consistence of standard mortar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a flow table PN-EN 13263-1 | PN-EN 413-2
276 Silica fume E Density
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Le Chatelier flask, using a helium pycnometer PB/LP-15
277 Silica fume E Sampling
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 196-7
278 Hydraulic binders E Compressive strength
Force range (2,4 - 130,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 15368 | PN-EN 196-1 | PN-EN 459-2
279 Hydraulic binders E Flexural strength
Force range (0,2 - 5,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 196-1
280 Hydraulic binders E Standard consistence
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 413-2 | PN-EN 196-3
281 Hydraulic binders E Setting times
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 413-2 | PN-EN 196-3
282 Hydraulic binders E Soundness
Le Chatelier
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a ring PN-EN 196-3
283 Hydraulic binders E Bulk density
Range (0,1 - 5,0) kg/dm3
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 459-2
284 Hydraulic binders E Degree of grinding
Range (0,063 - 1,00) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: sieve PN-EN 196-6 | PN ISO 2591-1
285 Hydraulic binders E Consistence of standard mortar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a flow table using a plunger apparatus PN-EN 413-2
286 Hydraulic road binders E Compressive strength
Force range (2,4 - 240,0) kN Flexural strength Force range (0,2 - 10,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 13282-1 | PN-EN 13282-2 | PN-EN 196-1
287 Hydraulic road binders E Setting times
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 13282-1 | PN-EN 13282-2 | PN-EN 196-3
288 Hydraulic road binders E Soundness
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Le Chatelier ring based on observation of the cake surface PN-EN 13282-1 | PN-EN 13282-2 | PN-EN 196-3 | PN-EN 459-2
289 Hydraulic road binders E Degree of grinding
Range (0,063 - 1,00) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: sieve PN-EN 13282-1 | PN-EN 13282-2 | PN-EN 196-6 | PN ISO 2591-1
290 Hydraulic road binders E Density
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Le Chatelier flask, using a helium pycnometer PB/LP-15
291 Hydraulic road binders E Specific surface area
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: air permeability (Blaine) PN-EN 196-6
292 CEN standard sand E Compressive strength
Force range (2,4 - 240,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 196-1
293 CEN standard sand E Grading
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Sieve method PN-EN 196-1
294 Sludges, suspensions E Bulk density
Range (10,0 - 1000,0) cm3
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PB/LP-23
295 Cement, Building lime, Construction adhesives, Gypsum binders, Building mortars, Hydraulic binders and other building materials E Sampling for consumer tests
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PB/LP-25
296 Ground limestone E Bulk density
Range (0,1 - 5,0) kg/dm3
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 459-2
297 Ground limestone E Density
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Le Chatelier flask, using a helium pycnometer PB/LP-15
298 Ground limestone E Specific surface area
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: air permeability (Blaine) PN-EN 196-6
299 Ground limestone E Degree of grinding
Range (0,063 - 1,00) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: sieve PN-EN 196-6 | PN ISO 2591-1
300 Clinker E Bulk density (litre weight)
Range (0,1 - 5,0) kg/dm3
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 459-2
301 Adhesive and rendering compounds and mortars E Determination of particle size distribution
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: sieve ETAG 004 Europejskie Dokumenty Oceny
302 Building gypsum E Degree of whiteness
Range (50,0 - 100,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a spectrophotometer VGB M 701 E
303 White cement and plasters E Degree of whiteness
Range (50,0 - 100,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a spectrophotometer PB/LP-26
304 Clinker for white cement production, building lime, limestone, glass sands, titanium white, zinc white E Degree of whiteness
Range (50,0 - 100,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a spectrophotometer PB/LP-26
305 Common cements and special cements, cements, cementitious binders E Loss on ignition content
Range (0,05 – 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
306 Common cements and special cements, cements, cementitious binders E Content of insoluble matter (NR)
Range (0,05 - 80,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2 | PN-B-19707
307 Common cements and special cements, cements, cementitious binders E Sulphuric anhydride SO3 content
Range (0,01 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
308 Common cements and special cements, cements, cementitious binders E Chloride Cl ̅ content
Range (0,0005 - 0,50)% Range (0,005 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric method; Volhard titrimetric method PN-EN 196-2
309 Common cements and special cements, cements, cementitious binders E Silicon dioxide SiO2 content
Range (0,10 - 99,9)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Spectrophotometric method PB/LC-5 PB/LC-6 | PN-EN 196-2
310 Common cements and special cements, cements, cementitious binders E Iron (III) oxide Fe2O3 content
Range (0,15 - 5,0)% Range (0,005 - 2,5)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method; Spectrophotometric method PN-EN 196-2
311 Common cements and special cements, cements, cementitious binders E Aluminium oxide Al2O3 content
Range (0,05 - 85,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
312 Common cements and special cements, cements, cementitious binders E C3A content (calculated), C4AF content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
BN-62/6731-03
313 Common cements and special cements, cements, cementitious binders E Calcium oxide CaO content
Range (0,01 - 65,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
314 Common cements and special cements, cements, cementitious binders E Magnesium oxide MgO content
Range (0,02 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
315 Common cements and special cements, cements, cementitious binders E Carbon dioxide CO2 content
Range (0,05 - 25,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
316 Common cements and special cements, cements, cementitious binders E Alkali content (Na2O, K2O)
Range (0,02 - 5,0)% Range (0,001 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame photometry method; Flame atomic absorption spectrometry FAAS PB/LC-12 | PN-EN 196-2 | ASTM C 114
317 Common cements and special cements, cements, cementitious binders E Sulfide content
Range (0,1 - 2,0)% Range (0,02 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Titrimetric method PN-EN 196-2
318 Common cements and special cements, cements, cementitious binders E Manganese content
Range (0,005 - 2,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN 196-2
319 Common cements and special cements, cements, cementitious binders E Free water (moisture) and dry substance content
Range (0,05 - 99,9)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB/LC-15
320 Common cements and special cements, cements, cementitious binders E Quantitative content of mineral components (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
CEN TR 196-4
321 Common cements and special cements, cements, cementitious binders E Free calcium oxide CaOfree content
Range (0,01 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PB/LC-22
322 Common cements and special cements, cements, cementitious binders E Phosphorus pentoxide P2O5 content
Range (0,001 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PB/LC-26
323 Common cements and special cements, cements, cementitious binders E Titanium oxide TiO2 content
Range (0,06 - 2,5)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN ISO 21587-2
324 Common cements and special cements, cements, cementitious binders E Pozzolanicity
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-5
325 Common cements and special cements, Carbonate raw materials for the production of cement and building lime, Cement constituents, Calcium aluminate cements, Masonry cements, Aluminosilicate materials, Sands, Mineral waste and additives for cement production, Waste code: 10 01 01; 10 01 02; 10 02 01; 10 01 80 E Content of oxides / elements, Range;, SiO2 (0,01 - 99,0)%, Si (0,005 - 46,0)%, Fe2O3 (0,01 - 81,0)%, Fe (0,007 - 57,0)%, Al2O3 (0,01 - 90,0)%, Al (0,005 - 48,0)%, TiO2 (0,01 - 41,0)%, Ti (0,006 - 24,0)%, CaO (0,01 - 98,0)%, Ca (0,007 - 70,0)%, MgO (0,01 - 78,0)%, Mg (0,006 - 47,0)%, K2O (0,01 - 40,0)%, K (0,008 - 33,0)%, Na2O (0,01 - 58,0)%, Na (0,007 - 43,0)%, Mn2O3 (0,01 - 10,0)%, Mn (0,007 - 7,0)%, Cr2O3 (0,01 - 10,0)%, Cr (0,007 - 7,0)%, P2O5 (0,01 - 40,0)%, P (0,004 - 17,0)%, SO3 (0,01 - 59,0)%, S (0,004 - 24,0)%, ZnO (0,01 - 10,0)%, Zn (0,008 - 8,0)%, SrO (0,01 - 20,0)%, Sr (0,008 - 17,0)%, Cl- (0,001 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: wavelength dispersive X-ray fluorescence spectrometry ISO 29581-2 | PN-EN ISO 12677 | PN-EN 196-2
326 Common cements and special cements, Carbonate raw materials for the production of cement and building lime, Cement constituents, Calcium aluminate cements, Masonry cements, Aluminosilicate materials, Ashes, Hydraulic binders, Mineral waste and additives for cement production, Masonry units, Solid fuels (also alternative fuels), lime, soils, cement-containing preparations, eluates (materials dissolved in an acid mixture) E Mercury (Hg) content
Range (0,002 - 4,000) ppm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: atomic absorption spectrometry (DMA-direct measurement) PB/LC-28
327 Common cements and special cements, Carbonate raw materials for the production of cement and building lime, Calcium aluminate cements, Masonry cements, Hydraulic binders, Cement-containing preparations, Clinker, slag E Content of water-soluble Cr (VI)
Range (0,01 - 25,0) ppm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PB/LC-19 | PN-EN 196-10 SFS 5183
328 Carbonate raw materials for the production of cement and building lime E Loss on ignition content
Range (0,05 – 50,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2 | PN-EN 459-2
329 Carbonate raw materials for the production of cement and building lime E Content of insoluble matter (NR)
Range (0,05 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2 | PN-EN 459-2
330 Carbonate raw materials for the production of cement and building lime E Sulphuric anhydride SO3 content
Range (0,01 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2 | PN-EN 459-2
331 Carbonate raw materials for the production of cement and building lime E Chloride Cl ̅ content
Range (0,0005 - 0,50)% Range (0,005 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric method; Volhard titrimetric method PN-EN 196-2
332 Carbonate raw materials for the production of cement and building lime E Silicon dioxide SiO2 content
Range (0,10 - 30,0)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Spectrophotometric method PB/LC-5 PB/LC-6 | PN-EN 196-2
333 Carbonate raw materials for the production of cement and building lime E Iron (III) oxide Fe2O3 content
Range (0,15 - 5,0)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method; Spectrophotometric method PN-EN 196-2
334 Carbonate raw materials for the production of cement and building lime E Aluminium oxide Al2O3 content
Range (0,05 - 8,5)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
335 Carbonate raw materials for the production of cement and building lime E Calcium oxide CaO content
Range (0,01 - 56,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2 | PN-EN 459-2
336 Carbonate raw materials for the production of cement and building lime E Magnesium oxide MgO content
Range (0,02 - 30,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2 | PN-EN 459-2
337 Carbonate raw materials for the production of cement and building lime E Carbon dioxide CO2 content
Range (0,05 - 50,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2 | PN-EN 459-2
338 Carbonate raw materials for the production of cement and building lime E Carbonate content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
I/LC-21
339 Carbonate raw materials for the production of cement and building lime E Alkali content (Na2O, K2O)
Range (0,02 - 5,0)% Range (0,001 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame photometry method; Flame atomic absorption spectrometry FAAS PB/LC-12 | PN-EN 196-2 | ASTM C 114
340 Carbonate raw materials for the production of cement and building lime E Sulphide S2- content
Range (0,1 - 2,0)% Range (0,02 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Titrimetric method PN-EN 196-2
341 Carbonate raw materials for the production of cement and building lime E Manganese content
Range (0,005 - 1,5)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN 196-2
342 Carbonate raw materials for the production of cement and building lime E Free water (moisture) and dry substance content
Range (0,05 - 99,9)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB/LC-15
343 Carbonate raw materials for the production of cement and building lime E Free calcium oxide CaOfree content
Range (0,01 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PB/LC-22 | PN-EN 1744-1
344 Carbonate raw materials for the production of cement and building lime E Phosphorus pentoxide P2O5 content
Range (0,001 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PB/LC-26
345 Carbonate raw materials for the production of cement and building lime E Titanium oxide TiO2 content
Range (0,06 - 2,5)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN ISO 21587-2
346 Carbonate raw materials for the production of cement and building lime E Total organic carbon content TOC
Range (0,02 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 13639 p.6 | PN-EN 197-1
347 Cement constituents E Loss on ignition content
Range (0,05 - 50,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
348 Cement constituents E Content of insoluble matter (NR)
Range (0,05 - 80,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2 | PN-EN 450-1 | PN-EN 197-1
349 Cement constituents E Sulphuric anhydride SO3 content
Range (0,01 - 59,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
350 Cement constituents E Chloride Cl ̅ content
Range (0,0005 - 0,50)% Range (0,005 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric method; Volhard titrimetric method PN-EN 196-2
351 Cement constituents E Silicon dioxide SiO2 content
Range (0,10 - 99,9)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Spectrophotometric method PB/LC-5 PB/LC-6 | PN-EN 196-2
352 Cement constituents E Iron (III) oxide Fe2O3 content
Range (0,15 - 15,0)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method; Spectrophotometric method PN-EN 196-2
353 Cement constituents E Aluminium oxide Al2O3 content
Range (0,05 - 85,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
354 Cement constituents E Calcium oxide CaO content
Range (0,01 - 65,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PB/LC-9 | PN-EN 196-2 | PN-EN 197-1
355 Cement constituents E Magnesium oxide MgO content
Range (0,02 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PB/LC-10 | PN-EN 196-2
356 Cement constituents E Carbon dioxide CO2 content
Range (0,05 - 45,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
357 Cement constituents E Alkali content (Na2O, K2O)
Range (0,02 - 5,0)% Range (0,001 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame photometry method; Flame atomic absorption spectrometry FAAS PB/LC-12 | PN-EN 196-2 | ASTM C 114
358 Cement constituents E Sulphide S2- content
Range (0,1 - 2,0)% Range (0,02 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Titrimetric method PN-EN 196-2
359 Cement constituents E Manganese content
Range (0,005 - 2,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN 196-2
360 Cement constituents E Free water (moisture) and dry substance content
Range (0,05 - 99,9)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB/LC-15
361 Cement constituents E Phosphorus pentoxide P2O5 content
Range (0,001 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PB/LC-26
362 Cement constituents E Titanium oxide TiO2 content
Range (0,06 - 2,5)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN ISO 21587-2
363 Cement constituents E Total organic carbon content TOC
Range (0,02 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 13639 p.6 | PN-EN 197-1
364 Limestone E Silicon dioxide SiO2 content
Range (0,10 - 99,9)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Spectrophotometric method PB/LC-5 PB/LC-6 | PN-EN 196-2
365 Limestone E Iron (III) oxide Fe2O3 content
Range (0,15 - 15,0)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method; Spectrophotometric method PN-EN 196-2
366 Limestone E Aluminium oxide Al2O3 content
Range (0,05 - 85,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
367 Limestone E Calcium oxide CaO content
Range (0,01 - 65,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PB/LC-9 | PN-EN 196-2 | PN-EN 197-1
368 Limestone E Magnesium oxide MgO content
Range (0,02 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PB/LC-10 | PN-EN 196-2
369 Limestone E Carbon dioxide CO2 content
Range (0,05 - 45,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2 | PN-EN 197-1
370 Limestone E Alkali content (Na2O, K2O)
Range (0,02 - 5,0)% Range (0,001 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame photometry method; Flame atomic absorption spectrometry FAAS PB/LC-12 | PN-EN 196-2 | ASTM C 114
371 Limestone E Sulphide S2- content
Range (0,1 - 2,0)% Range (0,02 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Titrimetric method PN-EN 196-2
372 Limestone E Manganese content
Range (0,005 - 2,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN 196-2
373 Limestone E Free water (moisture) and dry substance content
Range (0,05 - 99,9)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB/LC-15
374 Limestone E Phosphorus pentoxide P2O5 content
Range (0,001 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PB/LC-26
375 Limestone E Titanium oxide TiO2 content
Range (0,06 - 2,5)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN ISO 21587-2
376 Limestone E Total organic carbon content TOC
Range (0,02 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 13639 p.6 | PN-EN 197-1
377 Limestone E Fines content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Methylene blue method PN-EN 933-9
378 Limestone E Sulphuric anhydride SO3 content
Range (0,01 - 1,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
379 Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E Loss on ignition content
Range (0,05 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
380 Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E Content of insoluble matter (NR)
Range (0,05 - 80,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
381 Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E Sulphuric anhydride SO3 content
Range (0,01 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
382 Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E Chloride Cl ̅ content
Range (0,0005 - 0,50)% Range (0,005 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric method; Volhard titrimetric method PN-EN 196-2
383 Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E Silicon dioxide SiO2 content
Range (0,10 - 99,9)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Spectrophotometric method PB/LC-5 PB/LC-6 | PN-EN 196-2
384 Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E Iron (III) oxide Fe2O3 content
Range (0,15 - 85,0)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method; Spectrophotometric method PN-EN 196-2
385 Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E Aluminium oxide Al2O3 content
Range (0,05 - 85,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
386 Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E Calcium oxide CaO content
Range (0,01 - 65,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
387 Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E Magnesium oxide MgO content
Range (0,02 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
388 Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E Carbon dioxide CO2 content
Range (0,05 - 50,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
389 Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E Alkali content (Na2O, K2O)
Range (0,02 - 5,0)% Range (0,001 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame photometry method; Flame atomic absorption spectrometry FAAS PB/LC-12 | PN-EN 196-2 | ASTM C 114
390 Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E Sulphide S2- content
Range (0,1 - 2,0)% Range (0,02 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Titrimetric method PN-EN 196-2
391 Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E Manganese content
Range (0,005 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN 196-2
392 Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E Free water (moisture) and dry substance content
Range (0,05 - 99,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB/LC-15
393 Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E Titanium oxide TiO2 content
Range (0,001 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN ISO 21587-1 | PN-EN ISO 21587-2
394 Masonry cements, Hydraulic binders E Quantitative content of mineral components (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
CEN TR 196-4
395 Masonry cements, Hydraulic binders E Free calcium oxide CaOfree content
Range (0,01 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PB/LC-22
396 Masonry cements, Hydraulic binders, Mineral waste and additives for cement production E Phosphorus pentoxide P2O5 content
Range (0,001 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PB/LC-26
397 Building lime E Loss on ignition content
Range (0,05 - 30,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 459-2
398 Building lime E Sulphuric anhydride SO3 content
Range (0,01 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 459-2
399 Building lime E Silicon dioxide SiO2 content
Range (0,10 - 5,0)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Spectrophotometric method PB/LC-5 | PN-EN 196-2
400 Building lime E Calcium oxide CaO content
Range (0,5 - 99,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 459-2
401 Building lime E Magnesium oxide MgO content
Range (0,25 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 459-2
402 Building lime E Carbon dioxide CO2 content
Range (0,10 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 459-2
403 Building lime E Alkali content (Na2O, K2O)
Range (0,02 - 5,0)% Range (0,001 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame photometry method; Flame atomic absorption spectrometry FAAS PB/LC-12 | PN-EN 196-2 | ASTM C 114
404 Building lime E Manganese content
Range (0,005 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN 196-2
405 Building lime E Free water (moisture) and dry substance content
Range (0,05 - 99,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB/LC-15 | PN-EN 459-2
406 Building lime E Active lime content
Range (0,01 - 99,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 459-2
407 Aluminosilicate materials E Loss on ignition content
Range (0,05 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
408 Aluminosilicate materials E Sulphuric anhydride SO3 content
Range (0,01 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
409 Aluminosilicate materials E Chloride Cl ̅ content
Range (0,0005 - 0,50)% Range (0,005 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric method; Volhard titrimetric method PN-EN 196-2
410 Aluminosilicate materials E Silicon dioxide SiO2 content
Range (0,10 - 99,9)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Spectrophotometric method PB/LC-6 | PN-EN 196-2
411 Aluminosilicate materials E Iron (III) oxide Fe2O3 content
Range (0,15 - 20,0)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method; Spectrophotometric method PN-EN 196-2
412 Aluminosilicate materials E Aluminium oxide Al2O3 content
Range (0,05 - 85,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
413 Aluminosilicate materials E Calcium oxide CaO content
Range (0,01 - 30,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
414 Aluminosilicate materials E Magnesium oxide MgO content
Range (0,02 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
415 Aluminosilicate materials E Alkali content (Na2O, K2O)
Range (0,02 - 5,0)% Range (0,001 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame photometry method; Flame atomic absorption spectrometry FAAS PB/LC-12 | PN-EN 196-2 | ASTM C 114
416 Aluminosilicate materials E Sulphide S2- content
Range (0,1 - 2,0)% Range (0,02 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Titrimetric method PN-EN 196-2
417 Aluminosilicate materials E Manganese content
Range (0,005 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN 196-2
418 Aluminosilicate materials E Free water (moisture) and dry substance content
Range (0,05 - 99,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB/LC-15
419 Aluminosilicate materials E Phosphorus pentoxide P2O5 content
Range (0,001 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PB/LC-26
420 Aluminosilicate materials E Titanium oxide TiO2 content
Range (0,06 - 2,5)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN ISO 21587-2
421 Building lime, Ashes, Slags, Silica fume, Hydraulic binders, Aggregates, Mortars, plasters, building compounds and other materials, Masonry units, Gypsum products E Content of oxides / elements
SiO2 (0,01 - 99,0)% Si (0,005 - 46,0)% Fe2O3 (0,01 - 81,0)% Fe (0,007 - 57,0)% Al2O3 (0,01 - 90,0)% Al (0,005 - 48,0)% TiO2 (0,01 - 41,0)% Ti (0,006 - 24,0)% CaO (0,01 - 98,0)% Ca (0,007 - 70,0)% MgO (0,01 - 78,0)% Mg (0,006 - 47,0)% K2O (0,01 - 40,0)% K (0,008 - 33,0)% Na2O (0,01 - 58,0)% Na (0,007 - 43,0)% Mn2O3 (0,01 - 10,0)% Mn (0,007 - 7,0)% Cr2O3 (0,01 - 10,0)% Cr (0,007 - 7,0)% P2O5 (0,01 - 40,0)% P (0,004 - 17,0)% SO3 (0,01 - 59,0)% S (0,004 - 24,0)% ZnO (0,01 - 10,0)% Zn (0,008 - 8,0)% SrO (0,01 - 20,0)% Sr (0,008 - 17,0)% Cl (0,001 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Wavelength-dispersive X-ray fluorescence spectrometry ISO 29581-2 | PN-EN 196-2
422 Ashes E Loss on ignition content
Range (0,05 - 40,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 450-1 | PN-EN 196-2
423 Ashes E Content of insoluble matter (NR)
Range (0,05 - 80,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2 | PN-EN 197-1
424 Ashes E Sulphuric anhydride SO3 content
Range (0,01 - 15,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2 | PN-EN 197-1
425 Ashes E Chloride Cl ̅ content
Range (0,0005 - 0,50)% Range (0,005 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric method; Volhard titrimetric method PN-EN 196-2
426 Ashes E Silicon dioxide SiO2 content
Range (0,10 - 80,0)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Spectrophotometric method PB/LC-6 | PN-EN 450-1 | PN-EN 196-2 | PN-EN 197-1
427 Ashes E Iron (III) oxide Fe2O3 content
Range (0,15 - 25,0)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method; Spectrophotometric method PN-EN 196-2
428 Ashes E Aluminium oxide Al2O3 content
Range (0,05 - 30,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
429 Ashes E Calcium oxide CaO content
Range (0,01 - 25,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2 | PN-EN 197-1
430 Ashes E Magnesium oxide MgO content
Range (0,02 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
431 Ashes E Carbon dioxide CO2 content
Range (0,05 - 50,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2 | PN-EN 197-1
432 Ashes E Alkali content (Na2O, K2O)
Range (0,02 - 5,0)% Range (0,001 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame photometry method; Flame atomic absorption spectrometry FAAS PB/LC-12 | PN-EN 196-2 | PN-G-04528-10 | ASTM C 114
433 Ashes E Manganese content
Range (0,005 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN 196-2
434 Ashes E Phosphorus pentoxide P2O5 content
Range (0,001 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN 450-1 Załącznik C
435 Ashes E Titanium oxide TiO2 content
Range (0,06 - 2,5)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN ISO 21587-2
436 Ashes E Free water (moisture) and dry substance content
Range (0,05 - 99,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB/LC-15
437 Ashes E Free calcium oxide CaOfree content
Range (0,01 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PB/LC-22 | PN-EN 451-1
438 Ashes E SiO2react, Calculated
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 197-1 | PN-EN 196-2
439 Ashes E CaO2reakt, Calculated
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 197-1
440 Slags, silica fume E Loss on ignition content
Range (0,05 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
441 Slags, silica fume E Sulphuric anhydride SO3 content
Range (0,01 - 15,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
442 Slags, silica fume E Chloride Cl ̅ content
Range (0,0005 - 0,50)% Range (0,005 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric method; Volhard titrimetric method PN-EN 196-2
443 Slags, silica fume E Silicon dioxide SiO2 content
Range (0,10 - 99,9)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Spectrophotometric method PB/LC-5 PB/LC-6 | PN-EN 196-2
444 Slags, silica fume E Iron (III) oxide Fe2O3 content
Range (0,15 - 30,0)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method; Spectrophotometric method PN-EN 196-2
445 Slags, silica fume E Aluminium oxide Al2O3 content
Range (0,05 - 30,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
446 Slags, silica fume E Calcium oxide CaO content
Range (0,01 - 50,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
447 Slags, silica fume E Magnesium oxide MgO content
Range (0,02 - 15,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
448 Slags, silica fume E Alkali content (Na2O, K2O)
Range (0,02 - 5,0)% Range (0,001 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame photometry method; Flame atomic absorption spectrometry FAAS PB/LC-12 | PN-EN 196-2 | ASTM C 114
449 Slags E Sulphide S2- content
Range (0,1 - 2,0)% Range (0,02 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Titrimetric method PN-EN 196-2
450 Slags E Manganese content
Range (0,005 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN 196-2
451 Slags E Moisture content
Range (0,05 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 15167-1 Załącznik A
452 Silica fume E Free calcium oxide CaOfree content
Range (0,01 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 451-1
453 Silica fume E Titanium oxide TiO2 content
Range (0,001 - 3,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN ISO 21587-1 | PN-EN ISO 21587-2
454 Silica fume E Free water (moisture) and dry substance content
Range (0,05 - 25,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB/LC-15 | PN-EN 13263-1
455 Rapid hardening hydraulic road binders E Sulphuric anhydride SO3 content
Range (0,01 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 13282-1 | PN-EN 196-2
456 Normal hardening hydraulic road binders E Sulphuric anhydride SO3 content
Range (0,01 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 13282-2 | PN-EN 196-2
457 Products for external thermal insulation systems E Loss on ignition content
Range (0,05 - 99, 5)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method ZUAT-15/V.03/2003 ZUAT-15/V.04/2003
458 Products for external thermal insulation systems E Dry matter content
Range (0,05 - 99, 5)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method ZUAT-15/V.03/2003 ZUAT-15/V.04/2003 ETAG 004 Europejskie Dokumenty Oceny
459 Products for external thermal insulation systems E Ash content
Range (0,05 - 99, 5)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method ETAG 004 Europejskie Dokumenty Oceny
460 Reinforcing meshes/fabrics for thermal insulation systems E Organic matter content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Europejskie Dokumenty Oceny
461 Aggregates E Presence of humus
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Visual method PN-EN 1744-1
462 Aggregates E Fines content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Methylene blue method PN-EN 933-9
463 Aggregates E Loss on ignition content
Range (0,05 - 45,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2 | PN-EN 1744-1
464 Aggregates E Content of sulphates soluble in HCl acid
Range (0,01 - 59,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2 | PN-EN 1744-1
465 Aggregates E Chloride Cl ̅ content
Range (0,0005 - 0,50)% Range (0,005 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric method; Volhard titrimetric method PN-EN 196-2 | PN-EN 1744-1
466 Aggregates E Total sulfur content
Range (0,1 - 2,0)% Range (0,02 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Titrimetric method PN-EN 196-2 | PN-EN 1744-1
467 Aggregates E Free calcium oxide CaOfree content
Range (0,01 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PB/LC-22 | PN-EN 1744-1
468 Aggregates E Alkali content (Na2O, K2O)
Range (0,02 - 5,0)% Range (0,001 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame photometry method; Flame atomic absorption spectrometry FAAS PB/LC-12 | PN-EN 196-2 | ASTM C 114
469 Sands E Loss on ignition content
Range (0,05 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
470 Sands E Sulphuric anhydride SO3 content
Range (0,01 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
471 Sands E Silicon dioxide SiO2 content
Range (0,10 - 99,9)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Spectrophotometric method PB/LC-6 | PN-EN 196-2
472 Sands E Iron (III) oxide Fe2O3 content
Range (0,15 - 20,0)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method; Spectrophotometric method PN-EN 196-2
473 Sands E Aluminium oxide Al2O3 content
Range (0,05 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
474 Sands E Calcium oxide CaO content
Range (0,01 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PB/LC-9 | PN-EN 196-2
475 Sands E Magnesium oxide MgO content
Range (0,02 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PB/LC-10 | PN-EN 196-2
476 Sands E Carbon dioxide CO2 content
Range (0,05 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
477 Sands E Alkali content (Na2O, K2O)
Range (0,02 - 5,0)% Range (0,001 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame photometry method; Flame atomic absorption spectrometry FAAS PB/LC-12 | PN-EN 196-2 | ASTM C 114
478 CEN standard sand E Moisture content
Range (0,05 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB/LC-17
479 Admixtures for concrete, mortar and grout E Chloride Cl ̅ content
Range (0,0005 - 0,50)% Range (0,005 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric method; Volhard titrimetric method PN-EN 480-10
480 Admixtures for concrete, mortar and grout E Alkali content (Na2O, K2O)
Range (0,02 - 5,0)% Range (0,01 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame photometry method; Flame atomic absorption spectrometry FAAS PB/LC-12 | PN-EN 480-12
481 Admixtures for concrete, mortar and grout E Free water (moisture) and dry substance content
Range (0,05 - 99,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB/LC-15 | PN-EN 480-8
482 Admixtures for concrete, mortar and grout E pH
Range 0,5 - 13,0
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric method PB/LC-27 | ISO 4316
483 Gypsum binders and plasters E Sulphuric anhydride SO3 content
Range (0,01 - 59,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 13279-2
484 Mortars and building compounds E Chloride Cl ̅ content
Range (0,005 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Volhard titrimetric method PN-EN 1015-17
485 Masonry units E Loss on ignition content
Range (0,05 - 30,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
486 Masonry units E Sulphuric anhydride SO3 content
Range (0,01 - 40,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
487 Masonry units E Chloride Cl ̅ content
Range (0,0005 - 0,50)% Range (0,005 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric method; Volhard titrimetric method PN-EN 196-2
488 Masonry units E Silicon dioxide SiO2 content
Range (0,10 - 80,0)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Spectrophotometric method PB/LC-5 PB/LC-6 | PN-EN 196-2
489 Masonry units E Iron (III) oxide Fe2O3 content
Range (0,15 - 5,0)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method; Spectrophotometric method PN-EN 196-2
490 Masonry units E Aluminium oxide Al2O3 content
Range (0,05 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
491 Masonry units E Calcium oxide CaO content
Range (0,01 - 60,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
492 Masonry units E Magnesium oxide MgO content
Range (0,02 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PB/LC-10 | PN-EN 772-5
493 Masonry units E Carbon dioxide CO2 content
Range (0,05 - 50,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
494 Masonry units E Alkali content (Na2O, K2O)
Range (0,02 - 5,0)% Range (0,001 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame photometry method; Flame atomic absorption spectrometry FAAS PB/LC-12 | PN-EN 772-5 | PN-EN 196-2 | ASTM C 114
495 Masonry units E Sulphide S2- content
Range (0,1 - 2,0)% Range (0,02 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method; Titrimetric method PN-EN 196-2
496 Masonry units E Manganese content
Range (0,005 - 1,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN 196-2
497 Masonry units E Free water (moisture) and dry substance content
Range (0,05 - 99,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB/LC-15
498 Solutions of all construction products E pH
Range 0,5 - 13,0
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited
Potentiometric method PB/LC-27
499 Pigments and extenders E pH
Range 0,5 - 13,0
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited
Potentiometric method PN-EN ISO 787-9
500 Products containing surfactants E pH
Range 0,5 - 13,0
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited
Potentiometric method ISO 4316
501 Floor screeds and screed materials E pH
Range 0,5 - 13,0
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited
Potentiometric method PN-EN 13454-2
502 Gypsums E Loss on ignition content
Range (0,05 - 40,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited
Gravimetric method PN-EN 196-2
503 Gypsums E Sulphuric anhydride SO3 content
Range (0,01 - 59,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited
Gravimetric method PN-EN 196-2 VGB-M 701 e
504 Gypsums E Chloride Cl ̅ content
Range (0,0005 - 0,50)% Range (0,005 - 10,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited
Potentiometric method; Volhard titrimetric method PN-EN 196-2 VGB-M 701 e
505 Gypsums E Silicon dioxide SiO2 content
Range (0,10 - 10,0)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited
Gravimetric method; Spectrophotometric method PB/LC-5 | PN-EN 196-2 VGB-M 701 e
506 Gypsums E Iron (III) oxide Fe2O3 content
Range (0,15 - 2,0)% Range (0,005 - 0,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited
Titrimetric method; Spectrophotometric method PN-EN 196-2 VGB-M 701 e
507 Gypsums E Aluminium oxide Al2O3 content
Range (0,05 - 2,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited
Titrimetric method PN-EN 196-2 VGB-M 701 e
508 Gypsums E Calcium oxide CaO content
Range (0,01 - 40,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited
Titrimetric method PN-EN 196-2 VGB-M 701 e
509 Gypsums E Magnesium oxide MgO content
Range (0,02 - 6,5)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2 VGB-M 701 e
510 Gypsums E Alkali content (Na2O, K2O)
Range (0,02 - 5,0)% Range (0,001 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame photometry method; Flame atomic absorption spectrometry FAAS PB/LC-12 | PN-EN 196-2 VGB-M 701 e | ASTM C 114
511 Gypsums E Free water (moisture) and dry substance content
Range (0,05 - 99,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB/LC-15 VGB-M 701 e
512 Glass E Resistance to water
Range szkła o niższej odporności
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-ISO 719
513 Glass, kaolins and clays, magnesites and dolomites, zircon raw materials, other aluminosilicate materials E Content of oxides / elements, Range, SiO2 (0,01 - 99,0)%, Si (0,005 - 46,0)%, Fe2O3 (0,01 - 81,0)%, Fe (0,007 - 57,0)%, Al2O3 (0,01 - 90,0)%, Al (0,005 - 48,0)%, TiO2 (0,01 - 41,0)%, Ti (0,006 - 24,0)%, CaO (0,01 - 98,0)%, Ca (0,007 - 70,0)%, MgO (0,01 - 78,0)%, Mg (0,006 - 47,0)%, K2O (0,01 - 40,0)%, K (0,008 - 33,0)%, Na2O (0,01 - 58,0)%, Na (0,007 - 43,0)%, Cr2O3 (0,01 - 10,0)%, Cr (0,007 - 7,0)%, P2O5 (0,01 - 40,0)%, P (0,004 - 17,0)%, SO3 (0,01 - 59,0)%, S (0,004 - 24,0)%, ZnO (0,01 - 10,0)%, Zn (0,008 - 8,0)%, SrO (0,01 - 20,0)%, Sr (0,008 - 17,0)%, BaO (0,01 - 43,0)%, Ba (0,009 - 38,0)%, HfO2 (0,01 - 9,0)%, Hf (0,008 - 12,0)%, NiO (0,01 - 12,0)%, Ni (0,008 - 10,0)%, ZrO2 (0,01 - 65,0)%, Zr (0,007 - 48,0)%, CuO (0,01 - 8,0)%, Cu (0,008 - 7,0)%, PbO (0,01 - 10,0)%, Pb (0,009 - 9,0)%, V2O5 (0,01 - 10,0)%, V (0,006 - 5,6)%, Mn3O4 (0,01 - 80,0)%, Mn (0,007 - 58,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Wavelength-dispersive X-ray fluorescence spectrometry ISO 29581-2 | PN-EN ISO 12677
Centre for Sustainable Construction; Concrete and Lightweight Composites Research Group
514 Masonry mortars Frost resistance PN-B-04500:1985
515 Concrete Water permeability of concrete Method: pressure PN-B-06250:1988
516 Concrete Resistance to freezing Method: measurement of strength reduction and mass loss PN-B-06250:1988 p. 6.5
517 Masonry mortars E Sieve analysis
Range (0,063 - 8,0) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 1015-1
518 Masonry mortars E Consistence of fresh mortar
Range (100 - 300) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: flow table PN-EN 1015-3
519 Masonry mortars E Consistence of fresh mortar
Penetration range (0 - 70) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a penetrometer PN-EN 1015-4
520 Masonry mortars E Bulk density of fresh mortar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 1015-6
521 Masonry mortars E Air content in fresh mortar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: A – pressure; Method: B – alcohol PN-EN 1015-7
522 Masonry mortars E Workable life of fresh mortar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: penetrating rod PN-EN 1015-9
523 Masonry mortars E Workable life of fresh mortar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: flow table PN-EN 1015-9
524 Masonry mortars E Correction time of fresh mortar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: direct measurement PN-EN 1015-9
525 Masonry mortars E Density of dried hardened mortar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 1015-10
526 Masonry mortars E Flexural strength
Force range (0,05 - 6,0) kN Compressive strength Force range (1,0 - 100,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: constant rate of force increase PN-EN 1015-11
527 Masonry mortars E Adhesion to the substrate
Force range (0,1 - 15,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: Pull-off PN-EN 1015-12
528 Masonry mortars E Coefficient of water absorption due to capillary action of hardened mortar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 1015-18
529 Masonry mortars E Water vapour transmission coefficient of hardened rendering and plastering mortars
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 1015-19
530 Masonry mortars E Suitability of one-coat rendering mortars for substrates
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 1015-21
531 Masonry mortars + masonry units E Flexural tensile strength by the torsion method in the plane perpendicular to the plane of the wall and with failure by a crack in the bed joint for the masonry unit
Range (0,1 - 10) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: constant rate of force increase PN-EN 1052-5
532 Thermal insulation materials E Thermal conductivity
Range (0,001 - 0,500) W/(m×K)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Plate apparatus method with a heat flow density sensor PN-EN 12667 „N” | PN-ISO 8301 „N” | PN-EN 12664 „N” | PN-EN 12939 „N”
533 Products and systems for the protection and repair of concrete structures E Compressive strength
Force range (3,0 - 250,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: constant rate of force increase PN-EN 12190
534 Products and systems for the protection and repair of concrete structures E Adhesion
Force range (0,5 - 25,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: pull-off PN-EN 1542
535 Products and systems for the protection and repair of concrete structures E Capillary absorption
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: gravimetric PN-EN 13057
536 Products and systems for the protection and repair of concrete structures E Thermal compatibility
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: thermal cycles – reference method PN-EN 13687-1
537 Materials for floor screeds E Flexural strength
Force range (0,05 - 6,0) kN Compressive strength Force range (1,0 - 200,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: constant rate of force increase PN-EN 13892-2
538 Materials for floor screeds E Abrasion resistance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: Böhme – mass loss PN-EN 13892-3
539 Materials for floor screeds E Adhesion
Force range (0,1 - 15,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: Pull-off PN-EN 13892-8
540 Materials for floor screeds E Open time
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: flow PN-EN 13454-2
541 Materials for floor screeds E Shrinkage and swelling
Kaufmann
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: Grauff-type apparatus PN-EN 13454-2
542 Materials for floor screeds E Flowability
Range (30 - 300) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: flow PN-EN 12706
543 Materials for floor screeds E Dimensional changes of floor smoothing compounds
Kaufmann
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: Grauff-type apparatus PN-EN 13872
544 Materials for floor screeds E Consistency of fluid mortars
Range (100 - 300) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: flow PN-EN 13454-2
545 Materials for floor screeds E Consistency of stiff-plastic mortars
Range (100 - 300) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: flow table PN-EN 13454-2
546 Admixtures for masonry mortar and concrete E Conventional dry matter content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 480-8
547 Admixtures for masonry mortars E Consistence of fresh mortar
Penetration range (0 - 70) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a penetrometer PN-EN 1015-4
548 Admixtures for masonry mortars E Amount of water required to obtain a standard consistence
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 480-13
549 Admixtures for masonry mortars E Air content in fresh mortar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: A – pressure; Method: B – alcohol PN-EN 1015-7
550 Admixtures for masonry mortars E Workable life of fresh mortar
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: penetrating rod PN-EN 1015-9
551 Admixtures for masonry mortars E Flexural strength
Force range (0,05 - 6,0) kN Compressive strength Force range (1,0 - 100,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: constant rate of force increase PN-EN 1015-11
552 Admixtures for concrete E Setting time
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: Vicat apparatus PN-EN 480-2
553 Admixtures for concrete E Capillary absorption
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: gravimetric PN-EN 480-5
554 Admixtures for concrete E Consistency
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: slump PN-EN 12350-2
555 Admixtures for concrete E Consistency
Range (200 - 700) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: flow table PN-EN 12350-5
556 Admixtures for concrete E Compressive strength
Force range (22,5 - 3000) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: constant rate of force increase PN-EN 12390-3
557 Admixtures for concrete E Air content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: pressure PN-EN 12350-7
558 Fresh concrete E Consistency
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: slump PN-EN 12350-2
559 Fresh concrete E Air content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: pressure PN-EN 12350-7
560 Concrete E Compressive strength
Force range (22,5 - 3000) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: constant rate of force increase PN-EN 12390-3
561 Concrete E Depth of penetration of water under pressure
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 12390-8
562 Concrete E Density
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: gravimetric PN-EN 12390-7
563 Concrete E Resistance to freezing
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: measurement of strength reduction and mass loss PN-B-06265 Załącznik N
564 Concrete E Sampling
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 12350-1
565 Flexible waterproofing products, bitumen, plastic and rubber products E Watertightness
Range (0 - 100) kPa
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 1928 „N”
566 Thick-layer polymer-modified bituminous coatings E Watertightness
Range (0 - 100) kPa
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PN-EN 15820 „N”
567 Water-impermeable products E Watertightness
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: gravimetric PN-EN 14891 „N”
568 Renders based on organic binders E Water vapour transmission coefficient for free films
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: gravimetric PN-EN ISO 7783
569 Renders based on organic binders E Water permeability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: gravimetric PN-EN 1062-3
570 Renders based on organic binders E Adhesion
Force range (0,1 - 15,0) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: Pull-off PN-EN 1542
571 Renders based on organic binders E Thermal compatibility
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Method: thermal cycles-reference method PN-EN 13687-3
572 Calcium aluminate cement E Setting time
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: Vicat apparatus PN-EN 480-2
573 Aggregates E Grain composition, Fraction (0,063 - 80) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 933-1
574 Aggregates E Particle shape – flakiness index, Fraction (4 - 80) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 933-3
575 Aggregates E Particle shape – shape index
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 933-4
576 Aggregates E Percentage of crushed and broken surfaces in coarse aggregate particles, Fraction (4 - 63) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: macroscopic PN-EN 933-5
577 Aggregates E Sand equivalent value
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 933-8
578 Aggregates E Resistance to fragmentation, Fraction (4 - 16) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric Los Angeles PN-EN 1097-2
579 Aggregates E Bulk density and voids, Fraction (0 - 63) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 1097-3
580 Aggregates E Water content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 1097-5
581 Aggregates E Particle density and water absorption, Fraction (4 - 31,5) mm; (0,063 - 4) mm (0,063 - 31,5) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 1097-6 p.8, 9
582 Aggregates E Testing of the influence of recycled aggregate extract on the initial setting time
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 1744-6
583 Aggregates E Frost resistance, Fraction (4 - 63) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 1367-6 | PN-EN 1367-1
584 Aggregates E Drying shrinkage
Fraction (0 - 20) mm Kaufmann
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: Grauff-type apparatus PN-EN 1367-4
585 Aggregates E Content of light impurities, Fraction (0 - 63) mm
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 1744-1 p. 14.2
586 Aggregates E Abrasion resistance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Micro-Deval method PN-EN 1097-1
587 Aggregates E Alkali reactivity
Grauff Kaufmana
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Long-term method – measurement of length changes of beams – apparatus type ASTM C 1293
588 Aggregates E Alkali reactivity
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: accelerated beam test on mortar Procedura badawcza GDDKiA PB/1/18
589 Aggregates E Alkali reactivity
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: long-term beam test on concrete Procedura badawcza GDDKiA PB/2/18
590 Aggregates E Polishability
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PSV method PN-EN 1097-8
591 Aggregates E Simplified petrographic description
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 932-3
592 Aggregates E Sampling
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 932-1 p. 8.2, p.8.8, p.8.9
593 Concrete paving flags E Freeze/thaw resistance with de-icing salt
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 1339 Załącznik D
594 Concrete paving flags E Bending strength and breaking load
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 1339 Załącznik F
595 Concrete paving flags E Slip / skid resistance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 1339 Załącznik I
596 Concrete paving blocks E Freeze/thaw resistance with de-icing salt
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 1338 Załącznik D
597 Concrete paving blocks E Splitting tensile strength
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 1338 Załącznik F
598 Concrete paving blocks E Slip/slipping resistance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 1338 Załącznik I
599 Concrete kerb units E Resistance to de-icing salts
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: gravimetric PN-EN 1340 Załącznik D
600 Concrete kerb units E Flexural strength
Range (5 – 150) kN
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: constant rate of force increase PN-EN 1340 Załącznik F
601 Concrete kerb units E Slip/slipping resistance
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 1340 Załącznik I
Centre for Sustainable Construction; Cement Research Group
602 Solid fuels, Hard coal Volatile matter content
Range (10 - 65,0)%
Gravimetric method PN-ISO 562:2000
603 Industrial waste, mineral raw materials and building materials, slurries and sewage sludge Total carbon content
Range (0,01 - 95,0)%
High-temperature combustion with IR detection PN-EN 13137:2004
604 Industrial waste, mineral raw materials and building materials, slurries and sewage sludge Total organic carbon (TOC) content
Range (0,01 - 95,0)%
High-temperature combustion with IR detection PN-EN 13137:2004
605 Industrial waste, mineral raw materials and building materials, slurries and sewage sludge Total inorganic carbon content (TIC) (calculated) PN-EN 13137:2004
606 Coal-associated shales and silts Total carbon content
Range (0,01 - 95,0)%
High-temperature combustion with IR detection PN-EN 13137:2004
607 Coal-associated shales and silts Total organic carbon (TOC) content
Range (0,01 - 95,0)%
High-temperature combustion with IR detection PN-EN 13137:2004
608 Coal-associated shales and silts Total inorganic carbon content (TIC)
Range (0,01 - 35,0)%
High-temperature combustion with IR detection PN-EN 13137:2004
609 Solid fuels: E, Hard coal Total carbon content (TC)
Range (20,0 - 99,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with IR detection PN-G-04571
610 Solid fuels: E, Hard coal Gross calorific value
Range (25000 - 32000) kJ/kg Net calorific value (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Calorimetric method PN-ISO 1928
611 Solid fuels: E, Hard coal Ash content
Range (1,0 - 50,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-ISO 1171
612 Solid fuels: E, Hard coal Volatile matter content
Range (10 - 65,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-G-04516
613 Solid fuels: E, Hard coal Chlorine content
Range (0,050 - 1,50)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric titration method PN-ISO 587 p. 7.2.3.
614 Solid fuels: E, Hard coal Total moisture content
Range (1,0 - 50,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-ISO 589 Metoda B1 i B2
615 Solid fuels: E, Hard coal First-stage (free) moisture content
Range (1,0 - 50,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-ISO 589
616 Solid fuels: E, Hard coal Moisture content in the analytical sample
Range (0,5 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-ISO 11722
617 Solid fuels: E, Hard coal Second-stage moisture content (moisture remaining in the sample)
Range (0,1 - 20,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN- ISO 589 Metoda A1 i A2
618 Solid fuels: E, Hard coal Total moisture content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN- ISO 589 Metoda A1 i A2
619 Solid fuels: E, Hard coal Total sulfur content
Range (0,20 - 5,00)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with IR detection PN-G-04584
620 Carbonate raw materials E Total organic carbon (TOC) content
Range (0,01 - 35,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with IR detection PN-EN 13639
621 Industrial waste, mineral raw materials and construction materials, slurries and sewage sludge E Total carbon content
Range (0,01 - 95,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with IR detection PN-ISO 10694
622 Industrial waste, mineral raw materials and construction materials, slurries and sewage sludge E Total organic carbon (TOC) content
Range (0,01 - 95,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with IR detection PN-ISO 10694
623 Industrial waste, mineral raw materials and construction materials, slurries and sewage sludge E Total moisture content
Range (1,0 - 90,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB-4/BC
624 Industrial waste, mineral raw materials and construction materials, slurries and sewage sludge E Analytical moisture content
Range (0,1 - 50,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB-4/BC
625 Industrial waste, mineral raw materials and construction materials, slurries and sewage sludge E Moisture content in the air-dried sample
Range (1,0 - 50,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB-4/BC
626 Industrial waste, mineral raw materials and construction materials, slurries and sewage sludge E Transient moisture content
Range (1,0 - 70,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PB-4/BC
627 Industrial waste, mineral raw materials and construction materials, slurries and sewage sludge E Total moisture content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PB-4/BC
628 Industrial waste, mineral raw materials and construction materials, slurries and sewage sludge E Total sulfur content
Range (0,01 - 13,00)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with IR detection PB-2/BC
629 Industrial waste, mineral raw materials and building materials, sludges E Gross calorific value
Range (1000 - 20000) kJ/kg Net calorific value (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Calorimetric method PB-3/BC
630 Sewage sludge E Gross calorific value
Range (1000 - 20000) kJ/kg Net calorific value (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Calorimetric method PN-EN 15170
631 Aggregates E Alkali reactivity
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Accelerated method using the Graff Kauffman apparatus ASTM C1260
632 Coal shales and silts E Total carbon content
Range (0,01 - 95,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
High-temperature combustion with IR detection PN-ISO 10694
633 Coal shales and silts E Total organic carbon (TOC) content
Range (0,01 - 95,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
High-temperature combustion with IR detection PN-ISO 10694
634 Coal shales and silts E Total moisture content
Range (1,0 - 90,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Gravimetric method PB-4/BC
635 Coal shales and silts E Analytical moisture content
Range (0,1 - 50,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Gravimetric method PB-4/BC
636 Coal shales and silts E Moisture content in the air-dried sample
Range (1,0 - 50,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Gravimetric method PB-4/BC
637 Coal shales and silts E Free moisture content
Range (1,0 - 50,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Gravimetric method PB-4/BC
638 Coal shales and silts E Total moisture content (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
PB-4/BC
639 Coal shales and silts E Gross calorific value
Range (1000 - 20000) kJ/kg Net calorific value (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Calorimetric method PB-3/BC
640 Coal shales and silts E Total sulfur content
Range (0,01 - 5,0)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
High-temperature combustion with IR detection PB-2/BC
641 Building materials E Gross calorific value
Range (-3 - 40,00) MJ/kg
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Calorimetric method PN-EN ISO 1716 „N”
642 Granulated slag E Content of granulated blast furnace slag in cements
Range (0 - 100)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Optical microscopy method PN-B-19707 Załącznik B
643 Granulated slag E Glassy phase content in granulated blast furnace slag
Range (30 - 100)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011
Optical microscopy method PN-B-19707 Załącznik C
644 Cement E Heat of hydration
Range (50 - 500) J/g
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Semi-adiabatic method PN-EN 196-9
645 Cement E Resistance to sulphates
Range (0,005 - 10)%
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Mortar expansion in sodium sulphate solution method PN-B-19707 Załącznik A
646 Building materials (cement, sand, binders, concrete, mortar, grout, aggregate, glass, limestone, lime) waste (10 01 01, 10 01 02, 10 02 01, 10 13 80, 17 01 01, 17 01 07) E Leachability of heavy metals, Concentration range in the aqueous extract: As (0,05 - 100) mg/l, Cr (0,01 - 100) mg/l, Zn (0,01 - 100) mg/l, Pb (0,01 - 100) mg/l, Co (0,01 - 100) mg/l, Ni (0,01 - 100) mg/l, V (0,01 - 100) mg/l, Mo (0,01 - 100) mg/l, Cu (0,01 - 100) mg/l, Ba (0,005 - 100) mg/l, Cd (0,002 - 100) mg/l
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Inductively coupled plasma optical emission spectrometry (ICP-OES) PB-8/BC
647 Building materials (cement, sand, binders, concrete, mortar, grout, aggregate, glass, limestone, lime, microsilica), slags and ashes from the power industry, slags from the metallurgical industry and dusts E Heavy metal content, Concentration range: As (10 - 20000) mg/kg, Cr (2 - 20000) mg/kg, Zn (2 - 20000) mg/kg, Pb (2 - 20000) mg/kg, Co (2 - 20000) mg/kg, Ni (2 - 20000) mg/kg, V (2 - 20000) mg/kg, Mo (2 - 20000) mg/kg, Cu (2 - 20000) mg/kg, Ba (1 - 20000) mg/kg, Cd (0,4 - 20000) mg/kg
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Inductively coupled plasma optical emission spectrometry (ICP-OES) PB-10/BC
Centre for Refractory Materials; Refractory Materials Research Group
648 Silicon carbide and silicon carbide products and materials containing SiC Free C content
Range (0,01 - 1,0)%
High-temperature combustion method with detection in IR PN-EN ISO 21068-2:2010 pkt. 6.4.5
649 Refractory, ceramic and insulating raw materials and products, materials containing SiC and carbides, dusts and geological raw materials Total S content
Range (0,02 - 3,0)%
High-temperature combustion with IR detection PBA 43 wyd. 1 z dn. 27.07.2016
650 Refractory raw materials and materials and SiC Content of WC, SiO2, Al2O3, Fe2O3, CaO, MgO, TiO2, ZrO2, Cr2 O3, K2O, Na2O, P2O5
SiO2 (0,01 - 100)% Al2O3 (0,01 - 100)% Fe2O3 (0,02 - 16,00)% CaO (0,02 - 98,00)% MgO (0,03 - 100)% TiO2 (0,01 - 50,00) % ZrO2 (0,02 - 92,00)% Cr2O3 (0,01 - 51,00)% K2O (0,01 - 4,00)% Na2O (0,01 - 4,00)% P2O5 (0,01 - 5,00)% WO3 (0,01 - 3,00)%
Wavelength dispersive X-ray fluorescence spectrometry method (WDXRF) PN-EN ISO 12677:2011
651 Refractory raw materials and materials and SiC Loss on ignition
Range (0,00 - 90,00)%
Gravimetric method PN-EN ISO 12677:2011 | PN-EN ISO 26845:2009
652 SiC and SiC products Na, K content
Na (0,01 - 0,5) % K (0,01 - 0,5) %
Inductively coupled plasma optical emission spectrometry (ICP-OES) ISO 9286:2021 pkt. 4.7 | PN-EN ISO 11885:2009
653 Refractory materials and raw materials Density Pycnometric method PN-EN 993-2:1997 | PN-EN 993-2:1997/A1:2004
654 Dense shaped materials (with total porosity up to 45 %) Water absorption Water method under vacuum PN-92/H-04185
655 Dense shaped materials (with total porosity up to 45 %) Apparent density, open and total porosity Water method under vacuum PN-EN 993-1:2019-01
656 Insulating refractory products (with total porosity not less than 45 %) Apparent density and total porosity of insulating products
Range od 45 %
PN-EN 1094-4:1998
657 Granular refractory materials and raw materials Apparent density -
Open porosity and water absorption of granular materials
Water method under vacuum PBC-4-1/wyd. 6 z dnia 18.01.2010 r.
658 Unshaped refractory products: dense and insulating castables; ramming mixes Permanent linear change PN-EN ISO 1927-6:2013-06
659 Unshaped refractory products: dense and insulating castables; ramming mixes Geometric apparent density PN-EN ISO 1927-6:2013-06
660 Dense shaped refractory products (with a true porosity up to 45%) Permanent change in dimensions due to heating, Linear measurement with a vernier caliper (Method 2) PN-EN 993-10:2021-03
661 Shaped insulating refractory products Permanent change in dimensions due to heating PN-EN 1094-6:2001
662 Dense shaped refractory products (with a total porosity up to 45%) Compressive strength at ambient temperature
Range do 3000 kN
PN-EN 993-5:2019-01
663 Shaped insulating refractory products (with total porosity not less than 45%) Compressive strength at ambient temperature
Range do 400 kN
PN-EN ISO 8895:2007
664 Dense and insulating castables, ramming mixes – unshaped refractory products, Sample dimensions: 64x64 mm – dense castables and products 114x114 mm – insulating castables and products, Precast shapes and products made of dense and insulating castables and ramming mixes, Sample dimensions: 64x64 mm – dense castables and products 114x114 mm – insulating castables and products Compressive strength at ambient temperature
Range do 3000 kN
PN-EN ISO 1927-6:2013-06
665 Structural materials, ceramics, glass, composites, raw materials Microstructure and surface morphology
Qualitative analysis of chemical composition
Scanning electron microscopy method; Scanning electron microscopy method with an EDS system PBS-1 wyd. 1 z dnia 1.03.2014
666 Raw materials, refractory and construction products Presence of asbestos fibres Scanning electron microscopy method with an EDS system ISO 22262-1:2012
667 Polycrystalline materials - solid - powdered, Amorphous materials (asbestos, chemicals, chemical products including fertilisers, construction products, building materials, structural materials excluding metals) - materials containing carbonates Phase identification X-ray diffraction method PN-EN 13925-1:2007 z wyłączeniem pkt.7,5; 7,6; 7,7; 7,8; 7,9; 7,10; 7,11 | PN-EN 13925-2:2004 z wyłączeniem pkt.4,5; 6,3; 6,6
668 Single- and multi-phase materials and raw materials, including those containing an amorphous phase Quantitative phase composition X-ray diffraction method (Rietveld method) PN-EN 13925-1:2007 z wyłączeniem pkt.7,5; 7,6; 7,7; 7,8; 7,9; 7,10; 7,11
669 Silica and aluminosilicate products and raw materials containing quartz, Aluminosilicate and corundum products and raw materials containing: corundum (α-Al2O3) Quantitative phase composition X-ray diffraction method – (External standard method) PN-EN 13925-1:2007 z wyłączeniem pkt.7,5; 7,6; 7,7; 7,8; 7,9; 7,10; 7,11
670 Shaped refractory products: fired and unfired Thermal expansion, Temperature range: from 400 °C to 1500°C Differential method PN-EN 993-19:2006
671 Shaped refractory products: fired and unfired Compressive creep, Temperature range: from 400 °C to 1650°C Differential method PN-EN 993-9:1999
672 Shaped refractory products: fired and unfired Refractoriness under load, Temperature range: from 400 °C to 1700 °C Differential method PN-EN ISO 1893:2009
673 Ceramic raw materials, including refractory materials, glazes, fluxes, slags Characteristic temperatures
Temperature range do 1600 °C
Microscopic-photographic method PBT-7-1/wyd. 7 z dnia 26.05.2010 r.
Centre for Advanced Ceramics and Precast Products; Ceramics Research Group
674 Calcium silicate masonry units Water absorption PN-EN 772-21:2011
675 Calcium silicate masonry units Compressive strength max load 2000 kN PN-EN 772-1+A1:2015-10
676 Calcium silicate masonry units Net density, gross dry density PN-EN 772-13:2001
677 Calcium silicate masonry units Dimensions PN-EN 772-16:2011
678 Calcium silicate masonry units Freeze-thaw resistance in an automatic chamber temperature range: {(–15) - (+20)} °C PN-EN 772-18:2011
679 Clay masonry units Compressive strength max load 2000 kN PN-EN 772-1+A1:2015-10
680 Clay masonry units Active soluble salt content. Range
Na (0,5 - 1) mg/l K (0,5 - 2) mg/ Mg (0,5 - 1) mg/l
PN-EN 772-5:2016-06 | PN-EN 772-5:2016-06/AC:2017-08
681 Clay masonry units Water absorption
Cold water absorption
Boiling method PN-EN 772-7:2000 | PN-EN 772-21:2011
682 Clay masonry units Dimensions PN-EN 772-16:2011
683 Clay masonry units Freeze-thaw resistance in an automatic chamber
temperature range (–15°C) - (+20) °C
PN-B-12012:2022-07
684 Clay masonry units Net density, gross dry density PN-EN 772-13:2001
685 Floor coverings Critical slip angle DIN EN 16165:2023-02 Annex A, B, NB | EN 16165:2021-10 Annex B | EN 16165:2021-10 Annex A
686 Ceramic tiles and slabs Dimensions PN-EN ISO 10545-2:2018-12
687 Ceramic tiles and slabs Surface quality Visual method. PN-EN ISO 10545-2:2018-12
688 Ceramic tiles and slabs Water absorption Method of saturating samples with water by boiling; Vacuum saturation method PN-EN ISO 10545-3:1999 | PN-EN ISO 10545-3:2018-05
689 Ceramic tiles and slabs Flexural strength and breaking force (0,5 – 4) kN PN-EN ISO 10545-4:2019-04
690 Ceramic tiles and slabs Impact resistance Method for measuring the reflectance coefficient PN-EN ISO 10545-5:1999
691 Ceramic tiles and slabs Resistance to deep abrasion, Unglazed tiles PN-EN ISO 10545-6:2012
692 Ceramic tiles and slabs Surface abrasion resistance, Glazed tiles PN-EN ISO 10545-7:2000
693 Ceramic tiles and slabs Linear thermal expansion
Temperature range (25 - 100) °C
PN-EN ISO 10545-8:2014-09
694 Ceramic tiles and slabs Resistance to thermal shock in the temperature range (15 - 145) °C PN-EN ISO 10545-9:2013-12
695 Ceramic tiles and slabs Resistance to crazing for glazed tiles PN-EN ISO 10545-11:1998
696 Ceramic tiles and slabs Frost resistance, testing in an automatic chamber
{(–15) (+20)} °C
PN-EN ISO 10545-12:1999
697 Ceramic tiles and slabs Chemical resistance PN-EN ISO 10545-13:2017-01
698 Ceramic tiles and slabs Resistance to staining PN-EN ISO 10545-14:2015-11
699 Ceramic tiles and slabs Content of released lead and cadmium
Pb (0,1 - 20) mg/l Cd (0,02 - 3,0) mg/l
Flame atomic absorption spectrometry (FAAS) PN-EN ISO 10545-15:2021-11 „N”
700 Ceramic tiles and slabs Surface hardness on the Mohs scale PN-EN 101:1994
701 Ceramic tiles and slabs Critical slip angle DIN EN 16165:2023-02 Annex A, B, NB | EN 16165:2021-10 Annex B | EN 16165:2021-10 Annex A
702 Glass articles Hydrolytic resistance of glass grains at 98°C
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Titrimetric method PN–ISO 719:1994
703 Silicate surfaces. Articles intended to come into contact with foodstuffs Content of released lead and cadmium
Pb (0,1 - 20) mg/l Cd (0,02 - 3,0) mg/l
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Flame atomic absorption spectrometry (FAAS) PN-EN 1388–1:2000+Ap1:2002 | PN-EN 1388–2:2000
704 Glass and ceramic tableware and kitchenware Resistance to thermal shock
Range (15 - 140) °C
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-A-13004:1997 p. 3.6. | PN-B-13113:1986
705 Glass and ceramic tableware and kitchenware Resistance to thermal shock
Range (15 - 500) °C
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 1183:2000
706 Glass and ceramic tableware and kitchenware Water absorption
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 1217:2000
707 Glass and ceramic tableware and kitchenware Resistance to mechanical washing
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 12875-1:2008
708 Glass and ceramic tableware and kitchenware Surface quality of non-metallic products after mechanical washing
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Visual method PN-EN 12875-2:2006
709 Building materials and raw materials Radionuclide activity concentration
Radionuclide activity concentration 40K Range (40 - 2000) Bq/kg
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Gamma-ray spectrometry Poradnik ITB nr 455/2010 IL.1_1.10.03.21
710 Building materials and raw materials Radionuclide activity concentration
Radionuclide activity concentration 226Ra Range (3 - 1000) Bq/kg
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Gamma-ray spectrometry Poradnik ITB nr 455/2010 IL.1_1.10.03.21
711 Building materials and raw materials Radionuclide activity concentration
Radionuclide activity concentration 208Tl Range (3 - 1000) Bq/kg
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Gamma-ray spectrometry Poradnik ITB nr 455/2010 IL.1_1.10.03.21
712 Building materials and raw materials Radionuclide activity concentration
Radionuclide activity concentration 232Th (calculated)
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Poradnik ITB nr 455/2010 IL.1_1.10.03.21
713 Building materials and raw materials Radioactivity concentration indices I (calculated)
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Poradnik ITB nr 455/2010 IL.1_1.10.03.21
714 Sanitary appliances – washbasins – WC pans – bidets – urinals Dimensions PN-EN 31+A1:2014-07 | PN-EN 33:2019-06 | PN-EN 35:2014-07 | PN-EN 80:2002
715 Sanitary appliances – WC pans Water absorption PN-EN 997:2018-11
716 Sanitary appliances – wash basins – baths – shower trays Resistance to temperature changes
Range (10 - 90) °C
PN-EN 14688:2009 | PN-EN 14688+A1:2018-11 PN–EN 14516+A1:2012 | PN-EN 14516+A1:2018-12 PN–EN 14527+A1:2012 | PN-EN 14527+A1:2018-12
717 Sanitary appliances – WC pans – washbasins – bidets Resistance to load max load: 6 kN PN-EN 997:2018-11 | PN-EN 14688:2009 | PN-EN 14688+A1:2018-11 | PN-EN 14528:2009 | PN-EN 14528+A1:2018-11
718 Sanitary appliances – wash basins Abrasion resistance PN-EN 14688:2009 | PN-EN 14688+A1:2018-11
719 Sanitary appliances – wash basins Scratch resistance PN-EN 14688:2009 | PN-EN 14688+A1:2018-11
720 Sanitary appliances: – washbasins – bidets Flow rate through the overflow orifice
Range do 0,42 l/s
PN-EN 14688:2009 | PN-EN 14688+A1:2018-11 | PN-EN 14528:2009 | PN-EN 14528+A1:2018-11
721 Sanitary appliances – wash basins – baths – shower trays Resistance to chemical and staining agents PN-EN 14688:2009 | PN-EN 14688+A1:2018-11 PN–EN 14516+A1:2012 | PN-EN 14516+A1:2018-12 PN–EN 14527+A1:2012 | PN-EN 14527+A1:2018-12
722 Kitchen sinks Resistance to chemical and staining agents PN-EN 13310:2005 | PN-EN 13310+A1:2018-11
723 Kitchen sinks Abrasion resistance PN-EN 13310:2005 | PN-EN 13310+A1:2018-11
724 Kitchen sinks Scratch resistance PN-EN 13310:2005 | PN-EN 13310+A1:2018-11
725 Kitchen sinks Flow rate through the overflow orifice
Range do 0,42 l/s
PN-EN 13310:2005 | PN-EN 13310+A1:2018-11
726 Kitchen sinks Resistance to temperature changes
Range (10 - 90) °C
PN-EN 13310:2005 | PN-EN 13310+A1:2018-11
Centre for Advanced Ceramics and Precast Products; Aerated Concrete and Precast Products Research Group
727 Concrete (normal-weight, lightweight, heavyweight) Compressive strength
range (100 - 3000) kN
PN-EN 12390-3:2019-07
728 Concrete (normal-weight, lightweight, heavyweight) Flexural strength
range (20 - 1000) kN
PN-EN 12390-5:2019-08
729 Concrete (normal-weight, lightweight, heavyweight) Water absorption PN-88/B-06250
730 Concrete (normal-weight, lightweight, heavyweight) Resistance to freezing PN-88/B-06250 p. 6.5.1
731 Concrete (normal-weight, lightweight, heavyweight) Depth of penetration of water under pressure PN-EN 12390-8:2019-08
732 Natural stone Abrasion resistance Böhme disc method PN-EN 14157:2017-11
733 Aggregate concrete masonry units (small-sized wall units) External appearance:
flatness of the face surfaces
PN-EN 772-20:2002+A1: 2005
734 Aggregate concrete masonry units (small-sized wall units) Dimensions: length, width, height PN-EN 772-16:2011
735 Aggregate concrete masonry units (small-sized wall units) Density:
net in dry state gross in dry state
PN-EN 772-13:2001, p. 7.1, 7.2 | PN-EN 772-13:2001, p. 7.1, 7.3
736 Aggregate concrete masonry units (small-sized wall units) Compressive strength
Range (100 - 3000) kN
PN-EN 772-1:2015-10
737 Aggregate concrete masonry units (small-sized wall units) Frost resistance PN-B-19306:2004 | PN-B-19307:2004
738 Aggregate concrete masonry units (small-sized wall units) Water absorption PN-EN 772-11:2011
739 Aggregate concrete masonry units (small-sized wall units) Linear changes PN-EN 772-14:2002
740 Concrete paving block Water absorption PN-EN 1338:2005 załącznik E
741 Concrete paving block Abrasion resistance Method: on the Böhme disc PN-EN 1338:2005 załącznik H
742 Concrete paving block Freeze/thaw resistance PN-EN 1338:2005 załącznik D
743 Concrete paving block Splitting tensile strength
range (50 - 950) kN
PN-EN 1338:2005 załącznik F
744 Kerbs Water absorption PN-EN 1340:2004 załącznik E
745 Kerbs Abrasion resistance Böhme disc method PN-EN 1340:2004 załącznik H
746 Kerbs Freeze/thaw resistance PN-EN 1340:2004 załącznik D
747 Kerbs Flexural strength
range (20 - 1000) kN
PN-EN 1340:2004 załącznik F
748 Lintels excluding steel lintels Water absorption (capillary rise) – absorption coefficient
Range (0 - 10) g/m2-s
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Gravimetric method PN-EN 772-11:2011
749 Lintels excluding steel lintels Shear load-bearing capacity
range (20 - 100) kN
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 846-9:2016-06 „N”
750 Lintels excluding steel lintels Bending load capacity
range (20 - 100) kN
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 846-9:2016-06 „N”
751 Lintels excluding steel lintels Deflection
Range (0 - 25) mm
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Method: direct measurement PN-EN 846-9:2016-06 „N”
752 Lintels excluding steel lintels Geometric dimensions:
Range (0 - 5000) mm ­ Deviations from straightness Range (0 - 10) mm ­ Thickness of the reinforcement cover Range (0 - 80) mm
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Direct measurement method ­ Length, width, height PN-EN 846-11:2002
753 Pipes and fittings (non-pressure): - concrete - reinforced concrete Compressive strength of core drilled specimens
range (100 - 3000) kN
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 12504-1:2019-08 | PN-EN 12390-3:2019-07
754 Covering elements of manholes and inspection chambers made of concrete (unreinforced and steel fibre reinforced) and reinforced concrete Compressive strength of core drilled specimens
Range (100 - 3000) kN
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 12504-1:2019-08
755 Components of drainage channels for pedestrian and vehicular areas - channels - gratings and covers Strength (proof loads)
range (100 - 3000) kN
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 1433:2005+A1:2007 „N”
756 Components of drainage channels for pedestrian and vehicular areas - channels - gratings and covers Water absorption (absorptivity)
Range (0 - 10)%
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Method: gravimetric PN-EN 1433:2005+A1:2007
757 Components of drainage channels for pedestrian and vehicular areas - channels - gratings and covers Freeze/thaw resistance in de-icing salt
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Method: gravimetric PN-EN 1433:2005+A1:2007 „N”
758 Components of drainage channels for pedestrian and vehicular areas - channels - gratings and covers Watertightness
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 1433:2005+A1:2007 „N”
759 Components of drainage channels for pedestrian and vehicular areas - channels - gratings and covers Strength (proof loads)
Range (100 - 3000) kN
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 1433:2005+A1:2007 „N”
760 Components of drainage channels for pedestrian and vehicular areas - channels - gratings and covers Permanent deformation
Range (0 - 12) mm
Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Method: direct measurement PN-EN 1433:2005+A1:2007 „N”
761 Precast building products of autoclaved aerated concrete, Small-sized units Dimensions: length, width, height
Range do 1000 mm
PN-EN 772-16:2011
762 Precast building products of autoclaved aerated concrete, Small-sized units Surface flatness
diagonal do 1000 mm
PN-EN 772-20:2002+A1:2005
763 Precast building products of autoclaved aerated concrete, Small-sized units Parallelism of surfaces
height do 300 mm
PN-EN 772-16:2011
764 Precast building products of autoclaved aerated concrete, Small-sized units Density:
net in dry state gross in dry state
PN-EN 772-13:2001
765 Precast building products of autoclaved aerated concrete, Small-sized units Compressive strength:
Range (2 - 200) kN
PN-EN 772-1+A1:2015-10
766 Precast building products of autoclaved aerated concrete, Small-sized units Freeze/thaw resistance PN-EN 15304:2010
767 Precast building products of autoclaved aerated concrete, Small-sized units Thermal conductivity
Range (0,005 - 0,5) W/mK
PN-ISO 8301:1998
768 Construction products, building materials and masonry units: - autoclaved aerated concrete - precast building products Radionuclide activity concentration
Radionuclide activity concentration 40K Range (40 - 2000) Bq/kg
Gamma-ray spectrometry Poradnik ITB nr 455/2010 IL.1_1.10.03.21
769 Construction products, building materials and masonry units: - autoclaved aerated concrete - precast building products Radionuclide activity concentration
Radionuclide activity concentration 226Ra Range (3 - 1000) Bq/kg
Gamma-ray spectrometry Poradnik ITB nr 455/2010 IL.1_1.10.03.21
770 Construction products, building materials and masonry units: - autoclaved aerated concrete - precast building products Radionuclide activity concentration
Radionuclide activity concentration 208Tl Range (3 - 1000) Bq/kg
Gamma-ray spectrometry Poradnik ITB nr 455/2010 IL.1_1.10.03.21
771 Construction products, building materials and masonry units: - autoclaved aerated concrete - precast building products Radionuclide activity concentration: 232Th (calculated) Poradnik ITB nr 455/2010 IL.1_1.10.03.21
772 Construction products, building materials and masonry units: - autoclaved aerated concrete - precast building products Radioactivity concentration indices I (calculated) Poradnik ITB nr 455/2010 IL.1_1.10.03.21
773 Autoclaved aerated concrete Net dry density PN-EN 772-13:2001
774 Autoclaved aerated concrete Compressive strength
Range (2 - 200) kN
PN-EN 772-1:2015-10
775 Autoclaved aerated concrete Freeze/thaw resistance PN-EN 15304:2010
776 Autoclaved aerated concrete Shrinkage
Range do 25 mm
Graf-Kaufman method PN-EN 680:2008
777 Autoclaved aerated concrete Thermal conductivity
Range (0,005 - 0,5) W/mK
PN-ISO 8301:1998
778 Autoclaved aerated concrete Water absorption PN-EN 772-11:2011
779 Autoclaved aerated concrete Water vapour permeability PN-EN ISO 12572:2016-10 | PN-EN 772-15:2002
780 Construction products and materials - autoclaved aerated concrete - expanded polystyrene Water vapour permeability PN-EN ISO 12572:2016-10
781 Construction products and materials - autoclaved aerated concrete - expanded polystyrene Thermal conductivity
Range (0,005 - 0,5) W/mK
PN-ISO 8301:1998
782 Masonry, including ancillary products for masonry Shear strength
Range do 200 kN Bend test
PN-EN 1052-3:2004 | PN-EN 1052-3:2004/A1:2009
783 Admixtures for concrete Total chlorine
Range (0,005 - 1,00)%
Titrimetric method PN-EN ISO 1158:1999
784 Admixtures for concrete Water-soluble chlorides
Range (0,005 - 1,00)%
Titrimetric method PN-EN 480-10:2011
785 Metal products: - steel bars for the reinforcement of concrete - welded steel lattice girders - welded steel fabric Shear force of the welded joint - Fs
force (3 - 100) kN
Method: shear test PN-EN 10080:2007 pkt. 9.3 | PN-EN lSO 15630-2:2019-04E pkt 7
786 Metal products: - steel bars for the reinforcement of concrete - welded steel lattice girders - welded steel fabric Mechanical properties: -distinct yield strength Re,
proof strength, plastic extension Rp, tensile strength Rm, percentage elongation after fracture A, percentage total extension at maximum force Agt, force (3 - 1000) kN elongation ( 0,01 - 23,00) mm
Method: tensile test at room temperature PN-EN lSO 6892-1:2016 Metoda B | PN-EN lSO 6892-1:2020-05 Metoda B | PN-EN lSO 15630-1:2019-04E pkt 5 | PN-EN lSO 15630-2:2019-04E pkt 5
787 Metal products: - steel bars for the reinforcement of concrete - welded steel lattice girders - welded steel fabric Geometry of the ribbed surface:
rib height Range (0 - 3) mm spacing between ribs Range (0 - 150) mm inclination angle of the transverse rib Range (0° - 90°)
Method: direct measurement PN-EN lSO 15630-1:2019-04E pkt 10.3.1, 10.3.3, 10.3.6
788 Metal products: - steel bars for the reinforcement of concrete - welded steel lattice girders - welded steel fabric Mass per unit length
Range (0 - 16) kg, Range (0 - 1000) mm
Method: indirect measurement PN-EN lSO 15630-1:2019-04E pkt 12
789 Metal products: - steel bars for the reinforcement of concrete - welded steel lattice girders - welded steel fabric Bend test through an angle of 60° on a mandrel of diameter 6d at a temperature of (10 – 35) oC PN-EN ISO 15630-2:2019-04 pkt.6
Centre for Environmental Engineering
790 Waste gases Gas volume flow rate for dynamic pressures >10 Pa
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Stagnation pressure method PN-Z-04030-7:1994
791 Waste gases Sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-Z-04030-7:1994
792 Waste gases Dust concentration
Range (0,001 – 100) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Gravimetric method PN-Z-04030-7:1994
793 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-Z-04030-7:1994
794 Waste gases Concentration of: CO2, SO2
CO2 (0,5 - 20) % SO2 (6 - 700) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Non-dispersive infrared spectrometry (NDIR) PN-ISO 10396:2001
795 Waste gases Concentration of: O2, CO, CO2, NO, NO2, SO2
O2 (0,5 - 20)% CO (5 - 1200) mg/m3 CO2 (0,5 - 23)% NO (2,1 - 640) mg/m3 NO2 (7,4 - 200) mg/m3 SO2 (10 - 700) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Method using a zirconia cell; Fourier transform infrared spectrometry method (FT-IR) PN-ISO 10396:2001
796 Waste gases Emission of CO, NO, NO2, SO2 (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-ISO 10396:2001
797 Waste gases O2 concentration
Range (0,52 - 20)%
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Paramagnetic method PN-EN 14789:2006
798 Waste gases CO concentration
Range (5 - 1200) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Non-dispersive infrared spectrometry (NDIR) PN-EN 15058:2006
799 Waste gases CO emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 15058:2006
800 Waste gases Sampling for determination of SO2 concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 14791:2017-04
801 Waste gases SO2 concentration
Range (5 - 2000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Thoron method PN-EN 14791:2017-04
802 Waste gases SO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 14791:2017-04
803 Waste gases Water vapour concentration in flue ducts – H2O concentration
Range (4 - 35)% objętości
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Condensation adsorption method PN-EN 14790:2017-04
804 Waste gases NOx concentration
Range (3 - 980) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Chemiluminescence method (CLD) PN-EN 14792:2006
805 Waste gases NOx emission (NO and NO2 expressed as NO2) (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 14792:2006
806 Waste gases Sampling for determination of HCl
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 1911:2011
807 Waste gases HCl concentration
Range (0,3 - 2058) mg/m3 Range (0,05 - 200) mg w próbce
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Ion chromatography (IC) PN-EN 1911:2011
808 Waste gases HCl emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 1911:2011
809 Waste gases Sampling for determination of HF
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
ISO 15713:2006
810 Waste gases HF concentration
Range (0,13 - 1289,50) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Ionometric method) ISO 15713:2006
811 Waste gases HF emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
ISO 15713:2006
812 Waste gases Sampling for the determination of PCDD/PCDF mass concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Filtration-condensation method PN-EN 1948-1:2006
813 Waste gases PCDD/PCDF emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 1948-1:2006
814 Waste gases Sampling for determination of metals, As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 14385:2025-05
815 Waste gases Element concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V)
Range (0,000002 - 2,0) mg/m3 Range (0,00001 - 0,5) mg w próbce
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN 14385:2025-05
816 Waste gases Emission, As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 14385:2025-05
817 Waste gases Sampling for the determination of total mercury concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 13211+AC:2006
818 Waste gases Total mercury emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 13211+AC:2006
819 Waste gases Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon
Range (3,3 - 500) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Continuous flame ionization detection method PN-EN 12619:2013-05
820 Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 12619:2013-05
821 Waste gases NH3 concentration
Range (2,2 - 46) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Fourier transform infrared spectrometry (FT-IR) PN-ISO 10396:2001
822 Waste gases NH3 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-ISO 10396:2001
823 Waste gases Concentration/content of ammonia NH3
Range (0,004 - 4,72) mg w próbce NH3 Range (0,05 - 52,5) mg/m3 NH3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Spectrometric method Annex B EN-ISO 21887:2019 | PN-ISO 7150-1:2002
824 Waste gases NH3 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Annex B EN-ISO 21887:2019 | PN-ISO 7150-1:2002
825 Waste gases Sampling for determination of the mass concentration, NH3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
ISO 21877:2017
826 Waste gases NH3 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
ISO 21877:2017
827 Waste gases Sampling for determination of ammonia concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Aspiration method using absorbing solutions PB-LL-5 wyd. 1 z 30.03.2016 r.
828 Waste gases Sampling for determination of metals (Al, Ba, Sn, Zn, Fe, Mo)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 14385:2025-05 | PN-EN ISO 17294-2:2024-04
829 Waste gases Element concentrations (Al, Ba, Sn, Zn, Fe, Mo)
Range (0,000002 - 2,0) mg/m3 Range (0,00001 - 0,5) mg w próbce
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN 14385:2025-05 | PN-EN ISO 17294-2:2024-04
830 Waste gases Emission of Al, Ba, Sn, Zn, Fe, Mo (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 14385:2025-05 | PN-EN ISO 17294-2:2024-04
831 Waste gases Sampling for determination of the mass concentration of dioxin-like PCB
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Filtration-condensation method PN-EN 1948-4+A1:2014-03
832 Waste gases Emission of dioxin-like PCB (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 1948-4+A1:2014-03
833 General environment - waste gas samples collected into absorbing solutions Element content
Antimony (0,00001 - 0,5) mg in the sample Arsenic (0,00001 - 0,5) mg in the sample Barium (0,00001 - 0,5) mg in the sample Chromium (0,00001 - 0,5) mg in the sample Tin (0,00001 - 0,5) mg in the sample Zinc (0,00001 - 0,5) mg in the sample Aluminium (0,00001 - 0,5) mg in the sample Cadmium (0,00001 - 0,5) mg in the sample Cobalt (0,00001 - 0,5) mg in the sample Manganese (0,00001 - 0,5) mg in the sample Copper (0,00001 - 0,5) mg in the sample Molybdenum (0,00001 - 0,5) mg in the sample Nickel (0,00001 - 0,5) mg in the sample Lead (0,00001 - 0,5) mg in the sample Thallium (0,00001 - 0,5) mg in the sample Vanadium (0,00001 - 0,5) mg in the sample Iron (0,00001 - 0,5) mg in the sample
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN 14385:2025-05 | PN-EN ISO 17294-2:2024-04
834 General environment - waste gas samples collected into absorbing solutions Mercury (Hg) content
Range (0,1 - 500) μg w próbce
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Mercury cold vapour atomic absorption spectrometry (CVAAS) PN-EN 13211+AC:2006 | PN-EN ISO 12846:2012
835 General environment *) - waste gas samples collected on filters Element content
Antimony Range (0,0000025 - 2,5) mg w próbce Barium (0,0000025 - 2,5) mg in the sample Arsenic (0,0000025 - 2,5) mg in the sample Chromium (0,0000025 - 2,5) mg in the sample Tin (0,0000025 - 2,5) mg in the sample Zinc (0,0000025 - 2,5) mg in the sample Aluminium (0,0000025 - 2,5) mg in the sample Cadmium (0,0000025 - 2,5) mg in the sample Cobalt (0,0000025 - 2,5) mg in the sample Manganese (0,0000025 - 2,5) mg in the sample Copper (0,0000025 - 2,5) mg in the sample Molybdenum (0,0000025 - 2,5) mg in the sample Nickel (0,0000025 - 2,5) mg in the sample Lead (0,0000025 - 2,5) mg in the sample Thallium (0,00005 - 50) mg in the sample Vanadium (0,0000025 - 2,5) mg in the sample Iron (0,0000025 - 2,5) mg in the sample
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN 14385:2005-05 | PN-EN ISO 17294-2:2016-11
836 General environment *) - waste gas samples collected on filters Mercury (Hg) content
Range (0,25 - 500) μg w próbce
Mercury cold vapour atomic absorption spectrometry (CVAAS) PN-EN 13211+AC:2006 | PN-EN ISO 12846:2012
837 Waste gas dedusting equipment Dust concentration
Range (0,001 - 100) g/m3
Gravimetric method PN-Z-04030-7:1994 | PN-M-34129:1987 metoda A
838 Waste gas dedusting equipment Dust removal efficiency (calculated) PN-Z-04030-7:1994 | PN-M-34129:1987 metoda A
839 Automated Measuring Systems (AMS) Calibration (QAL2) for: dust, SO2, NOx, CO, O2, CO2, TVOC, HCl, HF, H2O
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 14181:2015
840 Automated Measuring Systems (AMS) Annual surveillance tests (AST) for: dust, SO2, NOx, CO, O2, CO2, TVOC, HCl, HF, H2O
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
PN-EN 14181:2015
841 Automated Measuring Systems (AMS) SO2 concentration
Range (5 - 2000) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Thoron method PN-EN 14791:2017-04
842 Automated Measuring Systems (AMS) HCl concentration
Range (0,3 - 2058) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Ion chromatography (IC) PN-EN 1911:2011
843 Automated Measuring Systems (AMS) HF concentration
Range (0,13 - 1289,50) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Ionometric method ISO 15713:2006
844 Automated Measuring Systems (AMS) Dust concentration
Range (0,001 - 100) g/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Gravimetric method PN-Z-04030-7:1994
845 Automated Measuring Systems (AMS) O2 concentration
Range (0,52 - 20)%
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Paramagnetic method PN-EN 14789:2006
846 Automated Measuring Systems (AMS) NOx concentration
Range (3 - 980) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Chemiluminescence method (CLD) PN-EN 14792:2006
847 Automated Measuring Systems (AMS) CO concentration
Range (5 - 1200) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Non-dispersive infrared spectrometry (NDIR) PN-EN 15058:2006
848 Automated Measuring Systems (AMS) CO2 concentration
Range (0,5 - 20)%
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Non-dispersive infrared spectrometry (NDIR) PN-ISO 10396:2001
849 Automated Measuring Systems (AMS) Concentration of organic substances in gaseous and vapour form expressed as total gaseous organic carbon
Range (3,3 - 500) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Continuous flame ionization detection method PN-EN 12619: 2013-05
850 Automated Measuring Systems (AMS) Water vapour concentration in flue ducts – H2O concentration
Range (4 - 35)% objętości
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.)
Condensation adsorption method PN-EN 14790:2017-04
851 Automated Measuring Systems (AMS) Calibration (QAL2) for: NH3 PN-EN 14181:2015
852 Automated Measuring Systems (AMS) Annual surveillance tests (AST) for: NH3 PN-EN 14181:2015
853 Automated Measuring Systems (AMS) NH3 concentration
Range (2,2 - 46) mg/m3
Fourier transform infrared spectrometry (FT-IR) PN-ISO 10396:2001
854 Landfill gases *), Biogas Gas concentrations CO2, O2, CH4
CH4 (0,2 - 100,0)% CO2 (0,2 - 100,0)% O2 Range (0,1 - 25,0)% Flow velocity Range (0,6 - 30,0) m/s
Infrared detection method (IR); Electrochemical method; Anemometric method PB-LL-6 wyd. 1 z 15.03.2016 r.
855 Water Sampling for chemical and physical testing PN-ISO 5667-4:2017-10 z wył. pkt.14,15,16 | PN-ISO 5667-6:2016-12 z wył. pkt. 7.5, 7.6, 8.2 | PN-ISO 5667-11:2017-10 z wył. pkt. 5.2, 6.2, 6.3
856 Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11
857 Water, Wastewater pH
Range 2,0 - 12,0
Potentiometric method PN-EN ISO 10523:2012
858 Water, Wastewater Electrical conductivity
Range (80,0 - 15 000) μS/cm
Conductometric method PN-EN 27888:1999
859 Water, Wastewater Dry residue
Range (10,0 - 1000) mg/l
Gravimetric method PB-LL-2 wyd. 1 z 15.03.2016 r.
860 Water, Wastewater Dissolved solids
Range (10,0 - 1000) mg/l
Gravimetric method PB-LL-2 wyd. 1 z 15.03.2016 r.
861 Water, Wastewater Total dissolved solids
Range (10,0 - 50 000) mg/l
Gravimetric method PN-EN 15216:2022-03
862 Water, Wastewater Total suspended solids *)
Range (2,0 - 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
863 Water, Wastewater Bromide concentration
Range (0,1 - 400) mg/l
Ion chromatography (IC) PN-EN ISO 10304-1:2009+AC:2012
864 Water, Wastewater Chloride concentration
Range (0,5 - 2000) mg/l
Ion chromatography (IC) PN-EN ISO 10304-1:2009+AC:2012
865 Water, Wastewater Fluoride concentration
Range (0,05 - 200) mg/l
Ion chromatography method (IC PN-EN ISO 10304-1:2009+AC:2012
866 Water, Wastewater Nitrite concentration
Range (0,03 - 120) mg/l
Ion chromatography (IC) PN-EN ISO 10304-1:2009+AC:2012
867 Water, Wastewater Nitrate concentration
Range (0,2 - 800) mg/l
Ion chromatography (IC) PN-EN ISO 10304-1:2009+AC:2012
868 Water, Wastewater Phosphate concentration
Range (0,13 - 500) mg/l
Ion chromatography (IC) PN-EN ISO 10304-1:2009+AC:2012
869 Water, Wastewater Sulfate concentration
Range (0,5 - 2000) mg/l
Ion chromatography (IC) PN-EN ISO 10304-1:2009+AC:2012
870 Water, Wastewater Ammonium ion concentration
Range (0,05 - 200) mg/l
Ion chromatography (IC) PN-EN ISO 14911:2002
871 Water, Wastewater Calcium concentration
Range (1,0 - 4000) mg/l
Ion chromatography (IC) PN-EN ISO 14911:2002
872 Water, Wastewater Magnesium concentration
Range (1,0 - 4000) mg/l
Ion chromatography (IC) PN-EN ISO 14911:2002
873 Water, Wastewater Sodium concentration
Range (0,5 - 2000) mg/l
Ion chromatography (IC) PN-EN ISO 14911:2002
874 Water, Wastewater Potassium concentration
Range (0,5 - 2000) mg/l
Ion chromatography (IC) PN-EN ISO 14911:2002
875 Water, Wastewater Lithium concentration
Range (0,05 - 200) mg/l
Ion chromatography (IC) PN-EN ISO 14911:2002
876 Water, Wastewater Element concentration
Antimony (0,00005 - 50) mg/l Arsenic (0,00005 - 50) mg/l Barium (0,00005 - 50) mg/l Beryllium (0,00005 - 50) mg/l Chromium (0,00005 - 50) mg/l Zinc (0,00005 - 50) mg/l Aluminium (0,00005 - 50) mg/l Cadmium (0,00005 - 50) mg/l Cobalt (0,00005 - 50) mg/l Manganese (0,00005 - 50) mg/l Molybdenum (0,00005 - 50) mg/l Copper (0,00005 - 50) mg/l Nickel (0,00005 - 50) mg/l Lead (0,00005 - 50) mg/l Selenium (0,00005 - 50) mg/l Thallium (0,00005 - 50) mg/l Vanadium (0,00005 - 50) mg/l Iron (0,00005 - 50) mg/l
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04
877 Water, Wastewater Total organic carbon TOC concentration
Range (1,00 - 1000) mg/l
High-temperature combustion with IR detection PN-EN 1484:1999
878 Water, Wastewater Dissolved organic carbon DOC concentration
Range (1,00 - 1000) mg/l
High-temperature combustion with IR detection PN-EN 1484:1999
879 Water, Wastewater Metal concentrations
Na (0,40 - 500) mg/l K (0,40 - 500) mg/l
Flame atomic emission spectrometry (FEAS) PN-ISO 9964-3:1994 | PN-ISO 9964-3/Ak:1997
880 Water, Wastewater Mercury (Hg) concentration
Range (0,0007 - 0,5) mg/l
Atomic absorption spectrometry with amalgamation technique PB-LL-20 wyd. 1 z 07.03.2016 r.
881 Water, Wastewater Mercury (Hg) concentration
Range (0,0005 - 0,5) mg/l
Mercury cold vapour atomic absorption spectrometry (CVAAS) PN-EN ISO 12846:2012
882 Water, Wastewater Total phosphorus concentration
Range (0,04 - 20,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
883 Water, Wastewater Chromium(VI) concentration
Range (0,010 - 5,00) mg/l
Spectrophotometric method PN-C-04604-08:1977
884 Water Chromium(VI) concentration
Range (0,010 - 5,00) mg/l
Spectrophotometric method PN-EN ISO 18412:2007
885 Waste code: 19 12 10; 19 12 12; 20 01 38; 20 03 01 Sampling for physical and chemical testing
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue
PN-ISO 21645:2021-09
886 Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 04, 19 06 06, 19 06 99, 19 08 05, 19 12 10, 19 12 12, 20 01 08, 20 01 37, 20 01 38, 20 0201, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99 Sampling for physical and chemical testing
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue
PN-Z-15011-1:1998
887 Waste code: 20 03 01, 19 12 12 Morphological composition
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Gravimetric method PN-Z-15006:1993
888 Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 04, 19 06 06, 19 06 99, 19 08 01, 19 08 02, 19 08 05, 19 12 10, 19 12 12, 20 01 08, 20 01 37, 20 01 38, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 07, 20 03 99 Oxygen demand (AT4)
Range (1 - 80) mg/g O2
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Manometric method PB-LL-4 wyd. 1 z 30.03.2016 r.
889 Waste code: 06 09 80; 06 09 81; 07 02 12; 07 02 13; 10 01 01; 10 01 02; 10 01 05; 10 01 80; 15 01 02; 15 01 05; 15 01 09; 16 01 19; 17 02 03; 19 08 05; 19 12 04; 19 12 08; 19 12 10; 20 01 39; 20 02 02 Mercury (Hg) content
Range (0,005 - 100,0) mg/kg
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue
Atomic absorption spectrometry with amalgamation technique PB-LL-10 wyd. 3 z 29.11.2019 r.
890 Solid fuels: secondary fuel – alternative fuel, solid recovered fuel (SRF) Sampling for physical and chemical testing PN-EN ISO 21645:2021-09
891 Solid fuels: secondary fuel – alternative fuel, solid recovered fuel (SRF) Total moisture content
Range (0,5 - 80,0)%
Gravimetric method CEN/TS 15414-1:2010
892 Solid fuels: secondary fuel – alternative fuel, solid recovered fuel (SRF) Volatile matter content
Range (4,0 - 90,0)%
Gravimetric method PN-EN ISO 22167:2021-08
893 Solid fuels: secondary fuel – alternative fuel, solid recovered fuel (SRF) Biodegradable fraction content – mass fraction of biomass by the C14 carbon isotope method. Non-biodegradable fraction content – mass fraction of non-biomass by the C14 carbon isotope method
Range (5 - 100)%
Liquid scintillation method PN-EN ISO 21644:2021-07
894 Solid fuels: secondary fuel – alternative fuel, solid recovered fuel (SRF) Biodegradable fraction content – mass fraction of biomass Non-biodegradable fraction content – mass fraction of non-biomass
Range (5 - 100)%
Selective dissolution method PN-EN ISO 21644:2021-07
895 Solid fuels: solid biomass - solid biofuel Total organic carbon TOC content
Range (1,0 - 50)%
High-temperature combustion with IR detection PN-EN 15936:2022-07
896 Solid fuels: solid biomass - solid biofuel Total carbon TC content
Range (10 - 70)%
High-temperature combustion with TCD detection PN-EN ISO 16948:2015-07
897 Solid fuels: solid biomass - solid biofuel Biodegradable fraction content – mass fraction of biomass by the C14 carbon isotope method. Non-biodegradable fraction content – mass fraction of non-biomass by the C14 carbon isotope method
Range (5 - 100)%
Liquid scintillation method PN-EN ISO 21644:2021-07
898 Solid fuels: solid biomass - solid biofuel Dry matter
Range (35 - 99)%
Gravimetric method PN-EN 15934:2013-02
899 Solid fuels: solid biomass - solid biofuel Total moisture content
Range (1,0 - 54,0)%
Gravimetric method PN-EN ISO 18134-1:2023-02 | PN-EN ISO 18134-2:2024-10
900 Solid fuels: solid biomass - solid biofuel Moisture content in the analytical sample
Range (1,0 - 65)%
Gravimetric method PN-EN ISO 18134-3:2023-12
901 Solid fuels: solid biomass - solid biofuel Ash content
Range (0,3 - 12)%
Gravimetric method PN-EN ISO 18122:2023-05
902 Solid fuels: solid biomass - solid biofuel Element content
Antimony (0,25 - 2500) mg/kg Arsenic (0,25 - 2500) mg/kg Barium (0,25 - 2500) mg/kg Beryllium (0,25 - 2500) mg/kg Chromium (0,25 - 2500) mg/kg Zinc (0,25 - 2500) mg/kg Cadmium (0,25 - 2500) mg/kg Cobalt (0,25 - 2500) mg/kg Manganese (0,25 - 2500) mg/kg Copper (0,25 - 2500) mg/kg Molybdenum (0,25 - 2500) mg/kg Nickel (0,25 - 2500) mg/kg Lead (0,25 - 2500) mg/kg Selenium (0,25 - 2500) mg/kg Thallium (0,25 - 2500) mg/kg Vanadium (0,25 - 2500) mg/kg
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 16968:2015-07 | PN-EN ISO 17294-2:2024-04
903 Solid fuels: hard coal First-stage moisture content (transient moisture)
Range (0,5 - 50,0)%
Gravimetric method PN-ISO 589:2006 Metoda A2
904 Solid fuels: hard coal Second-stage moisture content (moisture remaining in the sample)
Range (0,5 - 20,0)%
Gravimetric method PN-ISO 589:2006 Metoda A2
905 Solid fuels: hard coal Total moisture content (calculated) PN-ISO 589:2006 Metoda A2
906 Solid fuels: hard coal Total moisture content
Range (5,0 - 50,0)%
Gravimetric method PN-ISO 589:2006 Metoda B2
907 Solid fuels: hard coal, lignite, coke Free moisture content
Range (0,5 - 50,0)%
Gravimetric method PN-G-04511:1980 pkt. 2.1
908 Solid fuels: hard coal, lignite, coke Moisture content in air-dried coal
Range (0,5 - 20,0)%
Gravimetric method PN-G-04511:1980 pkt. 2.2
909 Solid fuels: hard coal, lignite, coke Total moisture content (calculated) PN-G-04511:1980 pkt. 2.3.1
910 Solid fuels: hard coal, lignite, coke Total moisture content
Range (5,0 - 50,0)%
Gravimetric method PN-G-04511:1980 pkt. 2.3.2 i 2.3.4
911 Solid fuels: hard coal, lignite, coke Moisture content in the analytical sample
Range (0,1 - 16,0)%
Gravimetric method PN-G-04511:1980 pkt. 2.4
912 Solid fuels: hard coal, lignite, coke Ash content at 815 oC
Range (2,0 - 35,0)%
Gravimetric method PN-ISO 1171:2002
913 Solid fuels: hard coal, lignite, coke Volatile matter content at 850oC
Range (1,00 - 35,00)%
Gravimetric method PN-G-04516:1998
914 Solid fuels: hard coal, lignite, coke Mercury (Hg) content
Range (0,030 - 0,400) mg/kg
Atomic absorption spectrometry with amalgamation technique PB-LL-10 wyd. 3 z dnia 29.11.2019 r
915 Solid fuels: hard coal, lignite, coke Total phosphorus content
Range (0,010 - 0,100)%
Spectrophotometric method PB-LL-15 wyd.2 z dnia 04.09.2017 r.
916 Solid fuels: hard coal, lignite, coke Chlorine content
Range (0,03 - 0,30)%
Ion chromatography (IC) PB-LL-25 wyd.1 z dnia 04.09.2017 r.
917 Solid fuels: hard coal, lignite, coke Total carbon TC content
Range (50,0 - 82,0)%
High-temperature combustion with TCD detection PB-LL-28 wyd. 1 z 29.01.2018 r.
918 Solid fuels: hard coal, lignite, coke Hydrogen content
Range (2,40 - 7,00)%
High-temperature combustion with TCD detection PB-LL-28 wyd. 1 z 29.01.2018 r.
919 Solid fuels: hard coal, lignite, coke Sulfur content
Range (0,15 - 3,00) %
High-temperature combustion with TCD detection PB-LL-28 wyd. 1 z 29.01.2018 r.
920 Solid fuels: hard coal, lignite, coke Nitrogen content
Range (0,30 - 1,50)%
High-temperature combustion with TCD detection PN-G-04571:1998
921 Solid fuels: hard coal, lignite, coke Gross calorific value
Range (19 000 - 30 000) J/g Metoda calorimetric
PN-ISO 1928:2020-05
922 Solid fuels: hard coal, lignite, coke Net calorific value (calculated) PN-ISO 1928:2020-05
923 Liquid fuel: diesel fuel, heavy fuel oil, mazut Gross calorific value
Range (35 000 - 46 000) J/g
Calorimetric method PN-C-04062:2018-05
924 Liquid fuel: diesel fuel, heavy fuel oil, mazut Net calorific value (calculated) PN-C-04062:2018-05
925 Liquid fuels: - diesel fuel - liquid biofuels – fatty acid methyl esters Content of bio-based products using the C14 carbon isotope method
Range (3 - 100)%
Liquid scintillation method PB-LL-29 wydanie 3 z 26.05.2025r.
926 Liquid fuels: - liquid biofuels – diesel fuel with FAME Content of bio-based products using the C14 carbon isotope method
Range (3 - 30)%
Liquid scintillation method PB-LL-29 wydanie 3 z 26.05.2025r.
927 Raw materials, construction materials Element content
Antimony (0,25 - 4500) mg/kg Arsenic (0,25 - 2500) mg/kg Barium (0,25 - 2500) mg/kg Beryllium (0,25 - 3500) mg/kg Chromium (0,25 - 2500) mg/kg Zinc (0,25 - 5000) mg/kg Cadmium (0,10 - 2500) mg/kg Cobalt (0,10 - 2500) mg/kg Manganese (0,25 - 2500) mg/kg Copper (0,25 - 3000) mg/kg Molybdenum (0,20 - 2500) mg/kg Nickel (0,25 - 2500) mg/kg Lead (0,25 - 2500) mg/kg Selenium (0,25 - 4500) mg/kg Thallium (0,06 - 2500) mg/kg Vanadium (0,25 - 3500) mg/kg
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04 | PN-EN 13657:2006
928 Raw materials, construction materials Mercury (Hg) content
Range (0,005 - 100,0) mg/kg
Atomic absorption spectrometry with amalgamation technique PB-LL-10 wyd. 3 z 29.11.2019 r.
929 Soil Dry matter content
Range (0,5 - 99,5)%
Gravimetric method PN-ISO 11465:1999
930 Soil Water content (calculated) PN-ISO 11465:1999
931 Soil Loss on ignition of dry matter
Range (0,5 - 99,5)%
Gravimetric method PN-EN 15935:2022-01
932 Soil Element content
Antimony (0,25 - 2500) mg/kg Arsenic (0,25 - 2500) mg/kg Barium (0,25 - 3500) mg/kg Beryllium (0,25 - 3500) mg/kg Chromium (0,25 - 2500) mg/kg Tin (0,25 - 3500) mg/kg Zinc (0,25 - 3500) mg/kg Cadmium (0,10 - 2500) mg/kg Cobalt (0,25 - 2500) mg/kg Manganese (0,25 - 2500) mg/kg Copper (0,25 - 2500) mg/kg Molybdenum (0,25 - 2500) mg/kg Nickel (0,25 - 2500) mg/kg Lead (0,25 - 2500) mg/kg Selenium (0,25 - 2500) mg/kg Thallium (0,07 - 2500) mg/kg Vanadium (0,25 - 2500) mg/kg
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04 | PN-ISO 11466:2002
933 Soil Mercury (Hg) content
Range (0,05 - 30,0) mg/kg
Atomic absorption spectrometry with amalgamation technique PB-LL-10 wyd. 3 z 29.11.2019 r.
934 Sewage sludge Dry residue and water content
Range (0,5 - 99,5)%
Gravimetric method PN-EN 15934:2013-02
935 Sewage sludge Water content (calculated) PN-EN 15934:2013-02
936 Sewage sludge Loss on ignition of dry matter/organic matter
Range (0,5 - 99,5)%
Gravimetric method PN-EN 15935:2022-01
937 Sewage sludge Element content
Antimony (0,22 - 2500) mg/kg Arsenic (0,25 - 2500) mg/kg Barium (0,25 - 2500) mg/kg Beryllium (0,03 - 2500) mg/kg Chromium (0,25 - 2500) mg/kg Zinc (0,25 - 2600) mg/kg Cadmium (0,14 - 2500) mg/kg Cobalt (0,25 - 2500) mg/kg Manganese (0,25 - 2500) mg/kg Copper (0,25 - 2500) mg/kg Molybdenum (0,25 - 2500) mg/kg Nickel (0,25 - 2500) mg/kg Lead (0,25 - 2500) mg/kg Selenium (0,13 - 2500) mg/kg Thallium (0,03 - 2500) mg/kg Vanadium (0,25 - 2500) mg/kg
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04 | PN-EN 13346:2002
938 Sewage sludge Element content
Cadmium (8,0 - 200) mg/kg Copper (50,0 - 2000) mg/kg Nickel (15,0 - 1000) mg/kg Lead (20,0 - 2000) mg/kg Zinc (15,0 - 5000) mg/kg Chromium (10,0 - 3000) mg/kg
Flame atomic absorption spectrometry (FAAS) PN-EN 13346:2002 | PN-ISO 8288:2002
939 Sewage sludge Mercury (Hg) content
Range (0,3 - 25,0) mg/kg
Mercury cold vapour atomic absorption spectrometry (CVAAS) PN-EN 13346:2002 | PN-EN ISO 12846:2012
940 Sewage sludge Mercury (Hg) content
Range (0,005 - 25,0) mg/kg
Atomic absorption spectrometry with amalgamation technique PB-LL-10 wyd. 3 z 29.11.2019 r.
941 Sewage sludge Phosphorus content
Range (0,6 - 8,0)%
Spectrophotometric method PN-EN 13346:2002 | PN-EN ISO 6878:2006
942 Plastics, packaging materials Element content
Antimony (0,04 - 2500) mg/kg Arsenic (0,035 - 2500) mg/kg Barium (0,25 - 2500) mg/kg Beryllium (0,10 - 2500) mg/kg Chromium (0,07 - 2500) mg/kg Zinc (0,25 - 2500) mg/kg Cadmium (0,045 - 2500) mg/kg Cobalt (0,035 - 2500) mg/kg Manganese (0,25 - 2500) mg/kg Copper (0,25 - 2500) mg/kg Molybdenum (0,01 - 2500) mg/kg Nickel (0,10 - 2500) mg/kg Lead (0,10 - 2500) mg/kg Selenium (0,25 - 2500) mg/kg Thallium (0,10 - 2500) mg/kg Vanadium (0,025 - 2500) mg/kg
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04 | PN-EN 13657:2006
943 Plastics, packaging materials Fluorine content
Range (45 - 800) mg/kg
Ion chromatography method PN-EN 15408:2011
944 Plastics, packaging materials Mercury (Hg) content
Range (0,005 - 5,0) mg/kg
Atomic absorption spectrometry with amalgamation technique PB-LL-10 wyd. 3 z 29.11.2019 r.
945 Plastics, packaging materials Loss on ignition
Range (30,0 - 90,0)%
Gravimetric method PN-EN 15935:2022-01
946 Plastics, packaging materials Content of biogenic carbon – share of renewable components by the C14 carbon isotope method Content of non-biogenic carbon- share of non-renewable components by the C14 carbon isotope method
Range (5 - 100)%
Liquid scintillation method PN-EN ISO 21644:2021-07 | PN-EN 16640:2017+AC:2017-08
947 Plastics, packaging materials Total organic carbon TOC content
Range (1,0 - 90)%
High-temperature combustion with IR detection PN-EN 15936:2022-07
948 Plastics, packaging materials Total carbon TC content
Range (10 - 90)%
High-temperature combustion method PN-EN ISO 16948:2015-07 | PN-EN ISO 21663:2021-06
949 Plastics, packaging materials Total nitrogen content
Range (0,5 - 5,0)%
High-temperature combustion method PN-EN ISO 16948:2015-07
950 Fly ash, Waste code: 19 01 12; 19 01 14 Loss on ignition
Range (0,01 - 15,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Gravimetric method PN-EN 450-1:2012 | PN-EN 197-1:2012 | PN-EN 14227-4:2013-10 | PN-EN 196-2:2013-11
951 Fly ash, Waste code: 19 01 12; 19 01 14 Free calcium oxide content
Range (0,01 - 10,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Titrimetric method PN-EN 451-1:2017-06
952 Fly ash, Waste code: 19 01 12; 19 01 14 Chloride content
Range (0,002 - 5,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Titrimetric method PN-EN 196-2:2013-11
953 Fly ash, Waste code: 19 01 12; 19 01 14 Sulfate (SO3) content
Range (0,05 - 20,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Gravimetric method PN-EN 196-2:2013-11
954 Fly ash, Waste code: 19 01 12; 19 01 14 Silicon dioxide (SiO2) content
Range (0,01 - 70,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Gravimetric method PN-EN 196-2:2013-11
955 Fly ash, Waste code: 19 01 12; 19 01 14 Aluminium oxide content (Al2O3)
Range (0,04 - 35,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Titrimetric method PN-EN 196-2:2013-11
956 Fly ash, Waste code: 19 01 12; 19 01 14 Iron oxide content (Fe2O3)
Range (0,06 - 20,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Titrimetric method PN-EN 196-2:2013-11
957 Fly ash, Waste code: 19 01 12; 19 01 14 Calcium oxide content (CaO)
Range (0,08 - 30,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Titrimetric method PN-EN 196-2:2013-11
958 Fly ash, Waste code: 19 01 12; 19 01 14 Magnesium oxide content (MgO)
Range (0,06 - 20,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Titrimetric method PN-EN 196-2:2013-11
959 Fly ash, Waste code: 19 01 12; 19 01 14 Insoluble residue content (IR)
Range (0,01 - 95)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Gravimetric method PN-EN 196-2:2013-11
960 Fly ash, Waste code: 19 01 12; 19 01 14 Carbon dioxide content
Range (0,05 - 10,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Gravimetric method PN-EN 196-2:2013-11
961 Fly ash, Waste code: 19 01 12; 19 01 14 Sodium and potassium oxide content
Na2O (0,05 - 10,0)% K2O (0,05 - 10,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Flame atomic emission spectrometry (FEAS) PN-EN 196-2:2013-11
962 Fly ash, Waste code: 19 01 12; 19 01 14 Total alkali content (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
PN-EN 196-2:2013-11
963 Fly ash, Waste code: 19 01 12; 19 01 14 Reactive calcium oxide content (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
PN-EN 197-1:2012
964 Fly ash, Waste code: 19 01 12; 19 01 14 Reactive silicon dioxide content (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
PN-EN 197-1:2012
965 Fly ash, Waste code: 19 01 12; 19 01 14 Content of soluble phosphates (calculated as P2O5)
Range (0,006 - 200,0) mg/kg
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Spectrophotometric method PN-EN 450-1:2012 Załącznik C | PN-EN ISO 6878:2006
966 Fly ash, Waste code: 19 01 12; 19 01 14 Total phosphorus content (calculated as P2O5)
Range (0,10 - 2,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Spectrophotometric method PB-LL-16 wyd. 1 z 30.03.2016 r.
967 Fly ash, Waste code: 19 01 12; 19 01 14 Fineness
Range (0,6 - 90,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Sieving method PN-EN 14227-4:2013-10 | PN-EN 451-2:2017-06
968 Fly ash, Waste code: 19 01 12; 19 01 14 Compressive strength
Force range (10 - 300) kN
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
PN-EN 450-1:2012 | PN-EN 197-1:2012 | PN-EN 196-1:2016-07
969 Fly ash, Waste code: 19 01 12; 19 01 14 Activity index (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
PN-EN 450-1:2012
970 Fly ash, Waste code: 19 01 12; 19 01 14 Soundness
Range (0 - 5) mm Le Chatelier
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Method: using rings PN-EN 450-1:2012 | PN-EN 197-1:2012 | PN-EN 14227-4:2013-10 | PN-EN 196-3:2016-12
971 Fly ash, Waste code: 19 01 12; 19 01 14 Particle density
Range (1,50 - 3,00) Mg/m3
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Method: using a pycnometer PN-EN 1097-7:2023-04
972 Fly ash, Waste code: 19 01 12; 19 01 14 Initial setting
Range (10 - 500) min
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Method: using the Vicat apparatus PN-EN 450-1:2012 | PN-EN 196-3:2016-12
973 Fly ash, Waste code: 19 01 12; 19 01 14 Water demand
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Method: using a flow table PN-EN 450-1:2012 Załącznik B
974 Fly ash, Waste code: 10 01 01; 10 01 02;10 01 03; 10 01 17; 10 01 82; 19 01 12; 19 01 14 Mercury (Hg) content
Range (0,043 - 0,58) mg/kg
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Atomic absorption spectrometry with amalgamation technique PB-LL-10 wyd. 3 z 29.11.2019 r.
975 Waste E code: 10 01 Loss on ignition
Range (0,01 - 15,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 450-1 | PN-EN 197-1 | PN-EN 14227-4 | PN-EN 196-2
976 Waste E code: 10 01 Free calcium oxide content
Range (0,01 - 10,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 451-1
977 Waste E code: 10 01 Chloride content
Range (0,002 - 5,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
978 Waste E code: 10 01 Sulfate (SO3) content
Range (0,05 - 20,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
979 Waste E code: 10 01 Silicon dioxide (SiO2) content
Range (0,01 - 70,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
980 Waste E code: 10 01 Aluminium oxide content (Al2O3)
Range (0,04 - 35,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
981 Waste E code: 10 01 Iron oxide content (Fe2O3)
Range (0,06 - 20,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
982 Waste E code: 10 01 Calcium oxide content (CaO)
Range (0,08 - 30,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
983 Waste E code: 10 01 Magnesium oxide content (MgO)
Range (0,06 - 20,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Titrimetric method PN-EN 196-2
984 Waste E code: 10 01 Insoluble residue content (IR)
Range (0,01 - 95)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
985 Waste E code: 10 01 Carbon dioxide content
Range (0,05 - 10,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 196-2
986 Waste E code: 10 01 Sodium and potassium oxide content
Na2O (0,05 - 10,0)% K2O (0,05 - 10,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame atomic emission spectrometry (FEAS) PN-EN 196-2
987 Waste E code: 10 01 Total alkali content (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 196-2
988 Waste E code: 10 01 Reactive calcium oxide content (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 197-1
989 Waste E code: 10 01 Reactive silicon dioxide content (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 197-1
990 Waste E code: 10 01 Content of soluble phosphates (calculated as P2O5)
Range (0,006 - 200,0) mg/kg
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PN-EN 450-1 Załącznik C | PN-EN ISO 6878
991 Waste E code: 10 01 Total phosphorus content (calculated as P2O5)
Range (0,10 - 2,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrophotometric method PB-LL-16
992 Waste E code: 10 01 Fineness
Range (0,6 - 90,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Sieving method PN-EN 14227-4 | PN-EN 451-2
993 Waste E code: 10 01 Compressive strength
Force range (10 - 300) kN
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 450-1 | PN-EN 197-1 | PN-EN 196-1
994 Waste E code: 10 01 Activity index (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 450-1
995 Waste E code: 10 01 Soundness
Range (0 - 5) mm Le Chatelier
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using rings PN-EN 450-1 | PN-EN 197-1: | PN-EN 14227-4 | PN-EN 196-3
996 Waste E code: 10 01 Particle density
Range (1,50 - 3,00) Mg/m3
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a pycnometer PN-EN 1097-7
997 Waste E code: 10 01 Initial setting
Range (10 - 500) min
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using the Vicat apparatus PN-EN 450-1 | PN-EN 196-3
998 Waste E code: 10 01 Water demand
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Method: using a flow table PN-EN 450-1 Załącznik B
999 Silica fume Free calcium oxide content
Range (0,01 - 10,0)%
Titrimetric method PN-EN 451-1:2017-06
1000 Silica fume Silicon dioxide (SiO2) content
Range (0,01 - 99,0)%
Gravimetric method PN-EN 196-2:2013-11
1001 Silica fume Sulfate (SO3) content
Range (0,05 - 20,0)%
Gravimetric method PN-EN 196-2:2013-11
1002 Silica fume Chloride content (Cl-)
Range (0,002 - 5,0)%
Titrimetric method PN-EN 196-2:2013-11
1003 Silica fume Sodium and potassium oxide content, Na2O (0,05 - 5,0)%, K2O (0,05 - 5,0)% Flame atomic emission spectrometry (FEAS) PN-EN 196-2:2013-11
1004 Silica fume Total alkali content (calculated) PN-EN 196-2:2013-11
1005 Silica fume Loss on ignition
Range (0,01 - 30,0)%
Gravimetric method PN-EN 13263-1+A1:2010 | PN-EN 196-2:2013-11
1006 Silica fume Compressive strength
Force range (10 - 300) kN
PN-EN 13263-1+A1:2010 | PN-EN 196-1:2016-07
1007 Silica fume Activity index (calculated) PN-EN 13263-1+A1:2010
1008 Silica fume Dry matter content in suspension
Range (0,01 - 90,0)%
Gravimetric method PN-EN 13263-1+A1:2010
1009 Cement Flexural strength
Force range (1 - 15) kN
PN-EN 196-1:2016-07
1010 Cement Compressive strength
Force range (10 - 300) kN
PN-EN 196-1:2016-07
1011 Cement Setting time: Initial setting time
Range (10 - 500) min Final setting Range (10 - 2000) min
Method: using the Vicat apparatus PN-EN 196-3:2016-12
1012 Cement Soundness
Range (0 - 5) mm Le Chatelier
Method: using rings PN-EN 196-3:2016-12
1013 Cement Loss on ignition
Range (1,0 - 10,0)%
Gravimetric method PN-EN 196-2:2013-11
1014 Cement Sulfate (SO3) content
Range (0,05 - 20,0)%
Gravimetric method PN-EN 196-2:2013-11
1015 Cement Insoluble residue content (IR)
Range (0,05 - 95,0)%
Gravimetric method PN-EN 196-2:2013-11
1016 Cement Chloride content
Range (0,002 - 5,0)%
Titrimetric method PN-EN 196-2:2013-11
1017 Cement Sodium and potassium oxide content, Na2O (0,05 - 5,0)%, K2O (0,05 - 5,0)% Flame atomic emission spectrometry (FEAS) PN-EN 196-2:2013-11
1018 Cement Total alkali content (calculated) PN-EN 196-2:2013-11
1019 Cement Carbon dioxide content
Range (0,05 - 10,0)%
Gravimetric method PN-EN 196-2:2013-11
1020 Cement Sulfide content
Range (0,1 - 2,0)%
Titrimetric method PN-EN 196-2:2013-11
1021 Cement Fly ash content (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
PN-B-19707:2023-05P
1022 Cement Water-soluble chromium (VI) content
Range (0,000001 - 0,0012)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Spectrophotometric method PN-EN 196-10:2016-07
1023 Cement Quantitative content of components:
carbonate containing silicon dioxide containing blast furnace slag clinker setting time regulator (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
CEN TR 196-4:2007
1024 Cement Mercury (Hg) content
Range (0,05 - 0,17) mg/kg
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Atomic absorption spectrometry with amalgamation technique PB-LL-10 wyd. 3 z 29.11.2019 r.
1025 Building materials and raw materials, Waste code: 10 01 01; 10 01 02; 10 01 80 Radionuclide activity concentration
Radionuclide activity concentration 40K Range (40 - 2000) Bq/kg
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Gamma-ray spectrometry Poradnik ITB Nr 455/2010 IL.1_1.10.03.21
1026 Building materials and raw materials, Waste code: 10 01 01; 10 01 02; 10 01 80 Radionuclide activity concentration
Radionuclide activity concentration 226Ra Range (3 - 1000) Bq/kg
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Gamma-ray spectrometry Poradnik ITB Nr 455/2010 IL.1_1.10.03.21
1027 Building materials and raw materials, Waste code: 10 01 01; 10 01 02; 10 01 80 Radionuclide activity concentration
Radionuclide activity concentration 208Tl Range (3 - 1000) Bq/kg
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Gamma-ray spectrometry Poradnik ITB Nr 455/2010 IL.1_1.10.03.21
1028 Building materials and raw materials, Waste code: 10 01 01; 10 01 02; 10 01 80 Radionuclide activity concentration
Radionuclide activity concentration 232Th (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Poradnik ITB Nr 455/2010 IL.1_1.10.03.21
1029 Building materials and raw materials, Waste code: 10 01 01; 10 01 02; 10 01 80 Activity concentration indices, I (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Poradnik ITB Nr 455/2010 IL.1_1.10.03.21
1030 Gypsum Mercury (Hg) content
Range (0,21 - 15,3) mg/kg
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue.
Atomic absorption spectrometry with amalgamation technique PB-LL-10 wyd. 3 z 29.11.2019 r.
1031 Waste E, Code: 02 02; 02 03; 02 04; 02 05; 02 06; 02 07; 03 01; 03 03; 04 02; 15 01; 17 02; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 Sampling for physical and chemical testing
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PB-LL-22
1032 Waste E code: 02 01; 02 02; 02 03; 02 04; 02 05; 02 06; 02 07; 03 01; 03 03; 04 02; 07 02; 15 01; 16 01; 17 02; 19 01; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 Biodegradable fraction content – mass fraction of biomass by the C14 carbon isotope method Non-biodegradable fraction content – mass fraction of non-biomass by the C14 carbon isotope method
Range (25 - 100)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Liquid scintillation method PN-EN ISO 21644
1033 Waste E code: 02 02; 02 03; 02 04; 02 05; 02 06; 02 07; 03 01; 03 03; 04 02; 15 01; 16 03; 17 02; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 Biomass fraction content – mass fraction by the selective dissolution method
Range (20,0 - 100)% Content of the non-biomass fraction – mass fraction by the selective dissolution method Range (0,1 - 65,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 21644
1034 Waste E, Code: 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02; 17 05; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 Total organic carbon TOC content
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with IR detection PN-EN 15936
1035 Waste E, Code: 07 02; 07 05; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02; 17 05; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 Total carbon TC content
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with TCD detection PN-EN ISO 16948 | PN-EN ISO 21663
1036 Waste E, Code: 07 02; 07 05; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02; 17 05; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 Hydrogen content
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with TCD detection PN-EN ISO 16948 | PN-EN ISO 21663
1037 Waste E, Code: 07 02; 07 05; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02; 17 05; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 Sulfur content
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with TCD detection PN-EN ISO 16994 | PN-EN 15408
1038 Waste E, Code: 07 02; 07 05; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02; 17 05; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 Nitrogen content
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with TCD detection PN-EN ISO 21663
1039 Waste E, Code: 07 02; 07 05; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02; 17 05; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 Gross calorific value
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Calorimetric method PN-EN ISO 21654
1040 Waste E, Code: 07 02; 07 05; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02; 17 05; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 Net calorific value (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 21654
1041 Waste E, Code: 02 02; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02; 17 05; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 Element content
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN 13657 | PN-EN ISO 17294-2
1042 Waste E, Code: 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03; Loss on ignition (LOI)
Range (1,0 - 99,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 1593
1043 Waste E, Code: 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03; Dry matter
Range (1,0 - 99,0)%
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 15934
1044 Waste E, Code: 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03; Water content (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN 15934
1045 Waste E, Code: 02 02; 02 03; 02 04; 02 05; 02 06; 02 07; 03 01; 03 03; 04 02; 15 01; 16 03; 17 02; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 Total moisture content
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method CEN/TS 15414-1
1046 Waste E, Code: 02 02; 02 03; 02 04; 02 05; 02 06; 02 07; 03 01; 03 03; 04 02; 15 01; 16 03; 17 02; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 Moisture content in the analytical sample
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 21660-3
1047 Waste E, Code: 02 02; 02 03; 02 04; 02 05; 02 06; 02 07; 03 01; 03 03; 04 02; 15 01; 16 03; 17 02; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 Ash content
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 21656
1048 Waste E, Code: 02 02; 02 03; 02 04; 02 05; 02 06; 02 07; 03 01; 03 03; 04 02; 15 01; 16 03; 17 02; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 Chlorine content
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ion chromatography method PN-EN 15408
1049 Waste E, Code: 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 16 01; 17 01; 17 05; 19 01; 19 02; 19 03; Total moisture content
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method CEN/TS 15414-1
1050 Waste E, Code: 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 16 01; 17 01; 17 05; 19 01; 19 02; 19 03; Moisture content in the analytical sample
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 21660-3
1051 Waste E, Code: 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 16 01; 17 01; 17 05; 19 01; 19 02; 19 03; Ash content
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 21656
1052 Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Bromide concentration
Range (0,1 - 400) mg/l
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ion chromatography (IC) PN-EN ISO 10304-1 | PN-EN 12457-4
1053 Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Chloride concentration
Range (0,5 - 2000) mg/l
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ion chromatography (IC) PN-EN ISO 10304-1 | PN-EN 12457-4
1054 Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Fluoride concentration
Range (0,05 - 200) mg/l
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ion chromatography (IC) PN-EN ISO 10304-1 | PN-EN 12457-4
1055 Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Nitrite concentration
Range (0,03 - 120) mg/l Nitrite nitrogen concentration (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ion chromatography (IC) PN-EN ISO 10304-1 | PN-EN 12457-4
1056 Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Nitrate concentration
Range (0,2 - 800) mg/l Nitrate nitrogen concentration (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ion chromatography (IC) PN-EN ISO 10304-1 | PN-EN 12457-4
1057 Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Phosphate concentration
Range (0,13 - 500) mg/l
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ion chromatography (IC) PN-EN ISO 10304-1 | PN-EN 12457-4
1058 Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Sulfate concentration
Range (0,5 - 2000) mg/l
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ion chromatography (IC) PN-EN ISO 10304-1 | PN-EN 12457-4
1059 Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Dissolved organic carbon DOC concentration
Range (1,00 - 1000) mg/l
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with IR detection PN-EN 1484 | PN-EN 12457-4
1060 Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Total dissolved solids (TDS) concentration and content
Range (10,0 - 50000) mg/l Range (100 - 500000) mg/kg
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 15216 | PN-EN 12457-4
1061 Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) pH
Range 2,0 - 12,0
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Potentiometric method PN-EN ISO 10523 | PN-EN 12457-4
1062 Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Electrical conductivity
Range (80,0 - 90 000) μS/cm
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Conductometric method PN-EN 27888 | PN-EN 12457-4
1063 Waste E (water extract), Code: 01 01; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Ammonium ion concentration
Range (0,05 - 200) mg/l Ammonium nitrogen concentration (calculated)
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ion chromatography (IC) PN-EN ISO 14911 | PN-EN 12457-4
1064 Waste E (water extract), Code: 01 01; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Calcium concentration
Range (1,0 - 4000) mg/l
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ion chromatography (IC) PN-EN ISO 14911 | PN-EN 12457-4
1065 Waste E (water extract), Code: 01 01; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Magnesium concentration
Range (1,0 - 4000) mg/l
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ion chromatography (IC) PN-EN ISO 14911 | PN-EN 12457-4
1066 Waste E (water extract), Code: 01 01; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Sodium concentration
Range (0,5 - 2000) mg/l
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ion chromatography (IC) PN-EN ISO 14911 | PN-EN 12457-4
1067 Waste E (water extract), Code: 01 01; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Potassium concentration
Range (0,5 - 2000) mg/l
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ion chromatography (IC) PN-EN ISO 14911 | PN-EN 12457-4
1068 Waste E (water extract), Code: 01 01; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Lithium concentration
Range (0,05 - 200) mg/l
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ion chromatography (IC) PN-EN ISO 14911 | PN-EN 12457-4
1069 Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) Element concentration and content
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2 | PN-EN 12457-4
1070 Waste E (water extract), Code: 10 01; 10 02; 10 03; 10 04; 10 05; 10 06; 10 11; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02, Ashes1) (water extract) Metal concentrations
Na (0,1 - 500, 0) mg/l K (0,1 - 500, 0) mg/l
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Flame atomic emission spectrometry (FEAS) PN-ISO 9964- | PN-EN 12457-4
1071 Waste E (water extract), Code: 01 01; 02 03; 10 01; 10 02; 10 03; 10 04; 10 05; 10 06; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 06; 17 09; 19 05; 19 08; 19 12; 20 03, Ashes E (water extract) Mercury (Hg) concentration
Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Atomic absorption spectrometry with amalgamation technique PB-LL-20 | PN-EN 12457-4
1072 Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) Total organic carbon TOC content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with IR detection PN-EN 15936
1073 Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) Total carbon TC content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with TCD detection PN-EN ISO 16948 | PN-EN ISO 21663
1074 Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) Hydrogen content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with TCD detection PN-EN ISO 21663
1075 Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) Sulfur content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with TCD detection PN-EN ISO 16994 | PN-EN 15408
1076 Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) Nitrogen content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
High-temperature combustion with TCD detection PN-EN ISO 21663
1077 Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) Chlorine content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Ion chromatography (IC) PN-EN 15408
1078 Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) Gross calorific value
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Calorimetric method PN-EN ISO 21654
1079 Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) Net calorific value (calculated)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
PN-EN ISO 21654
1080 Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) Dry matter
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN 15934:2013-02
1081 Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) Moisture content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 18134-1 | PN-EN ISO 18134-1 | PN-EN ISO 18134-2
1082 Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) Moisture content in the analytical sample
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 21660-3
1083 Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) Ash content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method PN-EN ISO 21656
1084 Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) Mercury (Hg) content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Atomic absorption spectrometry with amalgamation technique PB-LL-10
1085 Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) Element content
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN 13657 | PN-EN ISO 17294-2
Test methods
1086 Ceramic slabs and tiles Commission Decision number 98/437/WE
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope.
EN 14411:2016
1087 Lintels excluding steel lintels Commission Decision number 97/740/EC
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope.
EN 845-2:2013+A1:2016
1088 Drainage channels Commission Decision number 97/464/EC
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope.
EN 1433:2002 | EN 1433:2002/A1:2005
1089 Flat glass and profiled glass panes Commission Decision number 2000/245/EC
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope.
EN 572-9:2004 | EN 12150-2:2004 | EN 14449:2005+AC:2005 | EN 1863-2:2004 | EN 14179-2:2005
1090 Insulating glass units Commission Decision number 2000/245/EC
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope.
EN 1279-5:2005+A2:2010 | EN 1279-5:2018
1091 Cementitious tile adhesives Commission Decision number 1999/470/EC
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope.
EN 12004:2007+A1:2012 | EN 12004-1:2017
1092 Liquid-applied water impermeable products for use beneath ceramic tiling bonded with adhesives Commission Decision number 99/90/EC
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope.
EN 14891:2017
1093 Membranes Commission Decision number 99/90/EC
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope.
EN 15814:2011+A1:2012
1094 Damp-proof insulating layers Commission Decision number 99/90/EC
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope.
EN 14967:2006
1095 Gypsum products Commission Decision number 95/467/EC
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope.
EN 13279-1 :2008 | EN 12860:2001 + AC :2002 | EN 13963:2005 + AC :2006 | EN 14496:2005
1096 Products for finishing internal; external walls and ceilings Commission Decision number 98/437/EC
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope.
EN 13245-2:2008
1097 Floor coverings Commission Decision number 98/808/EC
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope.
EN 13813:2002 | EN 13454-1:2004
1098 Products related to concrete; mortar and grout Commission Decision number 99/469/EC
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope.
EN 1504-2:2004 | EN 1504-3:2005 | EN 1504-4:2004 | EN 1504-6:2006
1099 Masonry products and related products Commission Decision number 97/740/EC
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope.
EN 15824:2009 | EN 15824:2017
1100 Thermal insulation products Commission Decision number 99/91/EC
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope.
EN 13162:2012 +A1:2015 | EN 13163:2012 +A1:2015 | EN 13164:2012 +A1:2015 | EN 13165:2012 +A2:2016 | EN 13166:2012 +A2:2016 | EN 13167:2012 +A1:2015 | EN 13168:2012 +A1:2015 | EN 13169:2012 +A1:2015 | EN 13170:2012 +A1:2015 | EN 13171:2012 +A1:2015
1101 Reaction to fire
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011, as amended) Essential characteristics Technical specification The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 3 of Regulation No 305/2011) in the above scope.
EN ISO 1182 | EN ISO 11925-2 | EN 13823 | EN 1716 | EN ISO 9239-1
1102 Fire resistance
Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011, as amended) Essential characteristics Technical specification The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 3 of Regulation No 305/2011) in the above scope.
PN-EN 1364-1 | PN-EN 1365-1 | PN-EN 1634-1

Reference standards (611)

ASTM C 114
ASTM C 1293
ASTM C1260
Annex B EN-ISO 21887:2019
BN-62/6731-03
BN-80/6811-01
BN-85/7011-23
CEN TR 196-4
CEN TR 196-4:2007
CEN/TS 15414-1
CEN/TS 15414-1:2010
DIN 5033:1992 cz.3
DIN EN 16165:2023-02 Annex A, B, NB
EN 12004-1:2017
EN 12004-2
EN 12004:2007+A1:2012
EN 12150-2:2004
EN 1279-5:2005+A2:2010
EN 1279-5:2018
EN 12860:2001 + AC :2002
EN 13162:2012 +A1:2015
EN 13163:2012 +A1:2015
EN 13164:2012 +A1:2015
EN 13165:2012 +A2:2016
EN 13166:2012 +A2:2016
EN 13167:2012 +A1:2015
EN 13168:2012 +A1:2015
EN 13169:2012 +A1:2015
EN 13170:2012 +A1:2015
EN 13171:2012 +A1:2015
EN 13245-2:2008
EN 13279-1 :2008
EN 13454-1:2004
EN 13813:2002
EN 13823
EN 13963:2005 + AC :2006
EN 14179-2:2005
EN 1433:2002
EN 1433:2002/A1:2005
EN 14411:2016
EN 14449:2005+AC:2005
EN 14496:2005
EN 14891:2017
EN 14967:2006
EN 1504-2:2004
EN 1504-3:2005
EN 1504-4:2004
EN 1504-6:2006
EN 15814:2011+A1:2012
EN 15824:2009
EN 15824:2017
EN 16165:2021-10 Annex A
EN 16165:2021-10 Annex B
EN 1716
EN 1863-2:2004
EN 572-9:2004
EN 845-2:2013+A1:2016
EN ISO 1182
EN ISO 11925-2
EN ISO 9239-1
ETAG 004
ETAG 004 Europejskie Dokumenty Oceny
Europejskie Dokumenty Oceny
I/LC-21
ISO 15713:2006
ISO 21877:2017
ISO 22262-1:2012
ISO 29581-2
ISO 4316
ISO 9050 p. 3.5.3
ISO 9050 p. 3.6
ISO 9286:2021 pkt. 4.7
PB-10/BC
PB-2/BC
PB-3/BC
PB-4/BC
PB-8/BC
PB-BF-07
PB-BF-16
PB-BF-17
PB-LL-10
PB-LL-10 wyd. 3 z 29.11.2019 r.
PB-LL-10 wyd. 3 z dnia 29.11.2019 r
PB-LL-15 wyd.2 z dnia 04.09.2017 r.
PB-LL-16
PB-LL-16 wyd. 1 z 30.03.2016 r.
PB-LL-2 wyd. 1 z 15.03.2016 r.
PB-LL-20
PB-LL-20 wyd. 1 z 07.03.2016 r.
PB-LL-22
PB-LL-25 wyd.1 z dnia 04.09.2017 r.
PB-LL-28 wyd. 1 z 29.01.2018 r.
PB-LL-29 wydanie 3 z 26.05.2025r.
PB-LL-4 wyd. 1 z 30.03.2016 r.
PB-LL-5 wyd. 1 z 30.03.2016 r.
PB-LL-6 wyd. 1 z 15.03.2016 r.
PB/LC-10
PB/LC-12
PB/LC-15
PB/LC-15 VGB-M 701 e
PB/LC-17
PB/LC-19
PB/LC-22
PB/LC-26
PB/LC-27
PB/LC-28
PB/LC-5
PB/LC-5 PB/LC-6
PB/LC-6
PB/LC-9
PB/LP-15
PB/LP-20
PB/LP-23
PB/LP-25
PB/LP-26
PBA 43 wyd. 1 z dn. 27.07.2016
PBC-4-1/wyd. 6 z dnia 18.01.2010 r.
PBS-1 wyd. 1 z dnia 1.03.2014
PBT-7-1/wyd. 7 z dnia 26.05.2010 r.
PN ISO 2591-1
PN- ISO 589 Metoda A1 i A2
PN-88/B-06250
PN-88/B-06250 p. 6.5.1
PN-92/H-04185
PN-A-13004:1997 p. 3.6.
PN-B-02867 BS 8414
PN-B-04500:1985
PN-B-04500:1985 p.3.5
PN-B-06250:1988
PN-B-06250:1988 p. 6.5
PN-B-06265 Załącznik N
PN-B-10027:1993
PN-B-12012:2022-07
PN-B-13059:1985
PN-B-13083:1997
PN-B-13113:1986
PN-B-13153:1981
PN-B-13160:1985
PN-B-19306:2004
PN-B-19307:2004
PN-B-19707
PN-B-19707 Załącznik A
PN-B-19707 Załącznik B
PN-B-19707 Załącznik C
PN-B-19707:2023-05P
PN-C-04062:2018-05
PN-C-04604-08:1977
PN-EN 10080:2007 pkt. 9.3
PN-EN 1015-1
PN-EN 1015-10
PN-EN 1015-11
PN-EN 1015-12
PN-EN 1015-17
PN-EN 1015-18
PN-EN 1015-19
PN-EN 1015-21
PN-EN 1015-3
PN-EN 1015-4
PN-EN 1015-6
PN-EN 1015-7
PN-EN 1015-9
PN-EN 101:1994
PN-EN 1052-3:2004
PN-EN 1052-3:2004/A1:2009
PN-EN 1052-5
PN-EN 1062-3
PN-EN 1094-4:1998
PN-EN 1094-6:2001
PN-EN 1097-1
PN-EN 1097-2
PN-EN 1097-3
PN-EN 1097-5
PN-EN 1097-6 p.8, 9
PN-EN 1097-7
PN-EN 1097-7:2023-04
PN-EN 1097-8
PN-EN 1183:2000
PN-EN 12002:2010
PN-EN 12003:2010
PN-EN 12086
PN-EN 12087 „N”
PN-EN 12089
PN-EN 12150-1
PN-EN 12150-1 „N”
PN-EN 1217:2000
PN-EN 12190
PN-EN 12350-1
PN-EN 12350-2
PN-EN 12350-5
PN-EN 12350-7
PN-EN 12390-3
PN-EN 12390-3:2019-07
PN-EN 12390-5:2019-08
PN-EN 12390-7
PN-EN 12390-8
PN-EN 12390-8:2019-08
PN-EN 12457-4
PN-EN 12504-1:2019-08
PN-EN 12600 „N”
PN-EN 12619: 2013-05
PN-EN 12619:2013-05
PN-EN 12664 „N”
PN-EN 12667 „N”
PN-EN 12706
PN-EN 1279-2
PN-EN 1279-3
PN-EN 1279-4
PN-EN 1279-6 Zał. B p. B.4
PN-EN 12860
PN-EN 12875-1:2008
PN-EN 12875-2:2006
PN-EN 1288-3 „N”
PN-EN 12898
PN-EN 12939 „N”
PN-EN 13057
PN-EN 1308:2008
PN-EN 13137:2004
PN-EN 13211+AC:2006
PN-EN 1324:2008
PN-EN 13263-1
PN-EN 13263-1+A1:2010
PN-EN 13279-2
PN-EN 13282-1
PN-EN 13282-2
PN-EN 13310+A1:2018-11
PN-EN 13310:2005
PN-EN 13346:2002
PN-EN 1338 Załącznik D
PN-EN 1338 Załącznik F
PN-EN 1338 Załącznik I
PN-EN 1338:2005 załącznik D
PN-EN 1338:2005 załącznik E
PN-EN 1338:2005 załącznik F
PN-EN 1338:2005 załącznik H
PN-EN 1339 Załącznik D
PN-EN 1339 Załącznik F
PN-EN 1339 Załącznik I
PN-EN 1340 Załącznik D
PN-EN 1340 Załącznik F
PN-EN 1340 Załącznik I
PN-EN 1340:2004 załącznik D
PN-EN 1340:2004 załącznik E
PN-EN 1340:2004 załącznik F
PN-EN 1340:2004 załącznik H
PN-EN 13454-2
PN-EN 1346:2008
PN-EN 1348:2008
PN-EN 1348:2008 „N”
PN-EN 1363-1
PN-EN 1363-1:2001
PN-EN 1363-1:2001 z wył. P.7
PN-EN 1363-1:2012
PN-EN 1363-1:2020-07
PN-EN 1363-2:2001 z wył. P.7
PN-EN 13639
PN-EN 13639 p.6
PN-EN 1364-1
PN-EN 1364-1:2001 „N”
PN-EN 1364-1:2015-08 „N”
PN-EN 1365-1
PN-EN 1365-1:2001 „N”
PN-EN 1365-1:2013-08 „N”
PN-EN 13657
PN-EN 13657:2006
PN-EN 1367-1
PN-EN 1367-4
PN-EN 1367-6
PN-EN 13687-1
PN-EN 13687-3
PN-EN 13823 „N”
PN-EN 13872
PN-EN 1388–1:2000+Ap1:2002
PN-EN 1388–2:2000
PN-EN 13892-2
PN-EN 13892-3
PN-EN 13892-8
PN-EN 13925-1:2007 z wyłączeniem pkt.7,5; 7,6; 7,7; 7,8; 7,9; 7,10; 7,11
PN-EN 13925-2:2004 z wyłączeniem pkt.4,5; 6,3; 6,6
PN-EN 13963
PN-EN 14157:2017-11
PN-EN 14179-1
PN-EN 14179-1 „N”
PN-EN 14181:2015
PN-EN 14227-4
PN-EN 14227-4:2013-10
PN-EN 1433:2005+A1:2007
PN-EN 1433:2005+A1:2007 „N”
PN-EN 14385:2005-05
PN-EN 14385:2025-05
PN-EN 14428
PN-EN 14496
PN-EN 14516+A1:2018-12 PN–EN 14527+A1:2012
PN-EN 14527+A1:2018-12
PN-EN 14528+A1:2018-11
PN-EN 14528:2009
PN-EN 14647
PN-EN 14688+A1:2018-11
PN-EN 14688+A1:2018-11 PN–EN 14516+A1:2012
PN-EN 14688:2009
PN-EN 14789:2006
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2006
PN-EN 1484
PN-EN 1484:1999
PN-EN 14891
PN-EN 14891 p. A.6.8
PN-EN 14891 p.A.6.4
PN-EN 14891 „N”
PN-EN 15058:2006
PN-EN 15152
PN-EN 15167-1
PN-EN 15167-1 Załącznik A
PN-EN 15170
PN-EN 15216
PN-EN 15216:2022-03
PN-EN 15304:2010
PN-EN 15368
PN-EN 15408
PN-EN 15408:2011
PN-EN 1542
PN-EN 15820 „N”
PN-EN 1593
PN-EN 15934
PN-EN 15934:2013-02
PN-EN 15935:2022-01
PN-EN 15936
PN-EN 15936:2022-07
PN-EN 1607
PN-EN 1609 „N”
PN-EN 1634-1
PN-EN 1634-1+A1:2009 „N”
PN-EN 1634-1+A1:2018-03 „N”
PN-EN 16640:2017+AC:2017-08
PN-EN 16703
PN-EN 1744-1
PN-EN 1744-1 p. 14.2
PN-EN 1744-6
PN-EN 1863-1
PN-EN 1863-1 „N”
PN-EN 1911:2011
PN-EN 1928 „N”
PN-EN 1948-1:2006
PN-EN 1948-4+A1:2014-03
PN-EN 196-1
PN-EN 196-10 SFS 5183
PN-EN 196-10:2016-07
PN-EN 196-1:2016-07
PN-EN 196-2
PN-EN 196-2 VGB-M 701 e
PN-EN 196-2:2013-11
PN-EN 196-3
PN-EN 196-3:2016-12
PN-EN 196-5
PN-EN 196-6
PN-EN 196-7
PN-EN 196-9
PN-EN 197-1
PN-EN 197-1:
PN-EN 197-1:2012
PN-EN 27888
PN-EN 27888:1999
PN-EN 31+A1:2014-07
PN-EN 33:2019-06
PN-EN 356 „N”
PN-EN 35:2014-07
PN-EN 410 „N”
PN-EN 413-1
PN-EN 413-2
PN-EN 450-1
PN-EN 450-1 Załącznik B
PN-EN 450-1 Załącznik C
PN-EN 450-1:2012
PN-EN 450-1:2012 Załącznik B
PN-EN 450-1:2012 Załącznik C
PN-EN 451-1
PN-EN 451-1:2017-06
PN-EN 451-2
PN-EN 451-2:2017-06
PN-EN 459-2
PN-EN 480-10
PN-EN 480-10:2011
PN-EN 480-12
PN-EN 480-13
PN-EN 480-2
PN-EN 480-5
PN-EN 480-8
PN-EN 673 „N”
PN-EN 674
PN-EN 680:2008
PN-EN 772-1+A1:2015-10
PN-EN 772-11:2011
PN-EN 772-13:2001
PN-EN 772-13:2001, p. 7.1, 7.2
PN-EN 772-13:2001, p. 7.1, 7.3
PN-EN 772-14:2002
PN-EN 772-15:2002
PN-EN 772-16:2011
PN-EN 772-18:2011
PN-EN 772-1:2015-10
PN-EN 772-20:2002+A1: 2005
PN-EN 772-20:2002+A1:2005
PN-EN 772-21:2011
PN-EN 772-5
PN-EN 772-5:2016-06
PN-EN 772-5:2016-06/AC:2017-08
PN-EN 772-7:2000
PN-EN 80:2002
PN-EN 822
PN-EN 823
PN-EN 824
PN-EN 825
PN-EN 826 „N”
PN-EN 846-11:2002
PN-EN 846-9:2016-06 „N”
PN-EN 872:2007+Ap1:2007
PN-EN 932-1 p. 8.2, p.8.8, p.8.9
PN-EN 932-3
PN-EN 933-1
PN-EN 933-3
PN-EN 933-4
PN-EN 933-5
PN-EN 933-8
PN-EN 933-9
PN-EN 993-10:2021-03
PN-EN 993-19:2006
PN-EN 993-1:2019-01
PN-EN 993-2:1997
PN-EN 993-2:1997/A1:2004
PN-EN 993-5:2019-01
PN-EN 993-9:1999
PN-EN 997:2018-11
PN-EN ISO 10140-1 „N”
PN-EN ISO 10140-2
PN-EN ISO 10140-4
PN-EN ISO 10140-5
PN-EN ISO 10304-1
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523
PN-EN ISO 10523:2012
PN-EN ISO 10545-11:1998
PN-EN ISO 10545-12:1999
PN-EN ISO 10545-13:2017-01
PN-EN ISO 10545-14:2015-11
PN-EN ISO 10545-15:2021-11 „N”
PN-EN ISO 10545-2:2018-12
PN-EN ISO 10545-3:1999
PN-EN ISO 10545-3:2018-05
PN-EN ISO 10545-4:2019-04
PN-EN ISO 10545-5:1999
PN-EN ISO 10545-6:2012
PN-EN ISO 10545-7:2000
PN-EN ISO 10545-8:2014-09
PN-EN ISO 10545-9:2013-12
PN-EN ISO 1158:1999
PN-EN ISO 1182 „N”
PN-EN ISO 11885:2009
PN-EN ISO 11925-2 „N”
PN-EN ISO 12543-2 i 3
PN-EN ISO 12543-4
PN-EN ISO 12543-5
PN-EN ISO 12543-6
PN-EN ISO 12572:2016-10
PN-EN ISO 12677
PN-EN ISO 12677:2011
PN-EN ISO 12846:2012
PN-EN ISO 14911
PN-EN ISO 14911:2002
PN-EN ISO 1513
PN-EN ISO 15630-2:2019-04 pkt.6
PN-EN ISO 16535
PN-EN ISO 16948
PN-EN ISO 16948:2015-07
PN-EN ISO 16968:2015-07
PN-EN ISO 16994
PN-EN ISO 1716 „N”
PN-EN ISO 17294-2
PN-EN ISO 17294-2:2016-11
PN-EN ISO 17294-2:2024-04
PN-EN ISO 18122:2023-05
PN-EN ISO 18134-1
PN-EN ISO 18134-1:2023-02
PN-EN ISO 18134-2
PN-EN ISO 18134-2:2024-10
PN-EN ISO 18134-3:2023-12
PN-EN ISO 18412:2007
PN-EN ISO 1893:2009
PN-EN ISO 1927-6:2013-06
PN-EN ISO 21068-2:2010 pkt. 6.4.5
PN-EN ISO 21587-1
PN-EN ISO 21587-2
PN-EN ISO 21644
PN-EN ISO 21644:2021-07
PN-EN ISO 21645:2021-09
PN-EN ISO 21654
PN-EN ISO 21656
PN-EN ISO 21660-3
PN-EN ISO 21663
PN-EN ISO 21663:2021-06
PN-EN ISO 22167:2021-08
PN-EN ISO 26845:2009
PN-EN ISO 2811-1 ETAG 004 Europejskie Dokumenty Oceny
PN-EN ISO 29465
PN-EN ISO 29466
PN-EN ISO 29468
PN-EN ISO 29469
PN-EN ISO 29767
PN-EN ISO 354:2005 z wyłączeniem pkt. 7.3.1.
PN-EN ISO 6878
PN-EN ISO 6878:2006
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
PN-EN ISO 7459
PN-EN ISO 7783
PN-EN ISO 787-9
PN-EN ISO 8895:2007
PN-EN ISO 9239-1 „N”
PN-EN lSO 15630-1:2019-04E pkt 10.3.1, 10.3.3, 10.3.6
PN-EN lSO 15630-1:2019-04E pkt 12
PN-EN lSO 15630-1:2019-04E pkt 5
PN-EN lSO 15630-2:2019-04E pkt 5
PN-EN lSO 15630-2:2019-04E pkt 7
PN-EN lSO 6892-1:2016 Metoda B
PN-EN lSO 6892-1:2020-05 Metoda B
PN-EN-12600 „N”
PN-EN-1288-3 „N”
PN-EN-673 „N”
PN-G-04511:1980 pkt. 2.1
PN-G-04511:1980 pkt. 2.2
PN-G-04511:1980 pkt. 2.3.1
PN-G-04511:1980 pkt. 2.3.2 i 2.3.4
PN-G-04511:1980 pkt. 2.4
PN-G-04516
PN-G-04516:1998
PN-G-04528-00:1977
PN-G-04528-02:1977
PN-G-04528-03:1977
PN-G-04528-04:1977
PN-G-04528-05:1978
PN-G-04528-06:1977
PN-G-04528-07:1977
PN-G-04528-09:1979
PN-G-04528-10
PN-G-04528-11:1986
PN-G-04528-12:1977
PN-G-04571
PN-G-04571:1998
PN-G-04584
PN-H-04156-01:1981
PN-H-04156-02:1992
PN-H-04156-03:1992
PN-H-04156-04:1981
PN-H-04156-07:1981
PN-H-04156-08:1981
PN-H-04156-09:1981
PN-H-04159-07:1983
PN-ISO 10396:2001
PN-ISO 10694
PN-ISO 11465:1999
PN-ISO 11466:2002
PN-ISO 1171
PN-ISO 1171:2002
PN-ISO 11722
PN-ISO 1928
PN-ISO 1928:2020-05
PN-ISO 21645:2021-09
PN-ISO 562:2000
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 z wył. pkt. 5.2, 6.2, 6.3
PN-ISO 5667-4:2017-10 z wył. pkt.14,15,16
PN-ISO 5667-6:2016-12 z wył. pkt. 7.5, 7.6, 8.2
PN-ISO 587 p. 7.2.3.
PN-ISO 589
PN-ISO 589 Metoda B1 i B2
PN-ISO 589:2006 Metoda A2
PN-ISO 589:2006 Metoda B2
PN-ISO 7150-1:2002
PN-ISO 719
PN-ISO 7884-1
PN-ISO 7884-2
PN-ISO 8288:2002
PN-ISO 8301 „N”
PN-ISO 8301:1998
PN-ISO 9964-
PN-ISO 9964-3/Ak:1997
PN-ISO 9964-3:1994
PN-M-34129:1987 metoda A
PN-N-01252:1965
PN-O-79711:1989
PN-Z-04030-7:1994
PN-Z-15006:1993
PN-Z-15011-1:1998
PN–ISO 719:1994
Poradnik ITB Nr 455/2010 IL.1_1.10.03.21
Poradnik ITB nr 455/2010 IL.1_1.10.03.21
Procedura badawcza GDDKiA PB/1/18
Procedura badawcza GDDKiA PB/2/18
Regulamin EKG ONZ NR 43 Zał. 3 p. 9.1
Regulamin EKG ONZ nr 43 Zał. 3 p. 1, Zał.4 p.2, Zał. 5 p. 2, Zał. 8 p. 4
Regulamin EKG ONZ nr 43 Zał. 3 p. 2.1, Zał. 5 p. 3.1, Zał. 6 p. 4.3, Zał. 7 p. 3, Zał. 11 p. 3
Regulamin EKG ONZ nr 43 Zał. 3 p. 2.2, Zał. 6 p. 4.2
Regulamin EKG ONZ nr 43 Zał. 3 p. 4, Zał. 6 p. 5.1, Zał. 7 p. 4.1, Zał. 9 p. 2
Regulamin EKG ONZ nr 43 Zał. 3 p. 5
Regulamin EKG ONZ nr 43 Zał. 3 p. 6
Regulamin EKG ONZ nr 43 Zał. 3 p. 7
Regulamin EKG ONZ nr 43 Zał. 3 p. 9.2
Regulamin EKG ONZ nr 43 Zał. 3 p. 9.3
Regulamin EKG ONZ nr 43 Zał.3 p. 9.1
Regulamin EKG ONZ nr 43 Zał.3 p.3.1, Zał. 4 p. 3, Zał. 6 p. 3, Zał. 7 p. 3, Zał. 10 p.3, Zał. 11p. 3, Zał. 12 p. 3
VGB M 701 E
ZUAT-15/V.03/2003 ZUAT-15/V.04/2003
ZUAT-15/V.03/2003 ZUAT-15/V.04/2003 ETAG 004 Europejskie Dokumenty Oceny