🇵🇱 SIEĆ BADAWCZA ŁUKASIEWICZ PL
ConstructionEnvironmentMaterials & polymersWater & wastewaterPetrochemistry & fuels
SIEĆ BADAWCZA ŁUKASIEWICZ is a laboratory accredited by PCA under number AB 054 (Kraków, Poland). Its accreditation scope covers 1102 test methods in the following areas: Construction, Environment, Materials & polymers, Water & wastewater. Test objects include: Waste gases, Aggregates E, Water, Wastewater, Building lime E. Most frequently used techniques: Gravimetric method, Titrimetric method, Spectrophotometric method.
At a glance
- Accreditation number: PCA AB 054
- Methods in scope: 1102
- Types of test objects: 250
- Techniques used: 152
- City: Kraków, Poland
- Accreditation number
- AB 054
- Accreditation body
- PCA
- Address
- – INSTYTUT CERAMIKI, I MATERIAŁÓW BUDOWLANYCH, ul. Cementowa 8, 31-983 Kraków
- City
- Kraków, Poland
What this laboratory tests (250)
- Waste gases — 43 methods
- Aggregates E — 29 methods
- Water, Wastewater — 27 methods
- Building lime E — 24 methods
- Fly ash, Waste code: 19 01 12; 19 01 14 — 24 methods
- Waste E code: 10 01 — 24 methods
- Common cements and special cements, cements, cementitious binders E — 20 methods
- Carbonate raw materials for the production of cement and building lime E — 19 methods
- Ashes E — 18 methods
- Cement constituents E — 17 methods
- Cement — 16 methods
- Ceramic tiles and slabs — 16 methods
- Solid fuels: hard coal, lignite, coke — 16 methods
- Automated Measuring Systems (AMS) — 15 methods
- Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E — 15 methods
- and 235 more
Analytical techniques used (152)
- Gravimetric method — 162 methods
- Titrimetric method — 83 methods
- Spectrophotometric method — 62 methods
- Ion chromatography (IC) — 29 methods
- Method: gravimetric — 26 methods
- High-temperature combustion with IR detection — 22 methods
- Method: pull-off — 20 methods
- Method: using the Vicat apparatus — 19 methods
- Flame photometry method; Flame atomic absorption spectrometry FAAS — 15 methods
- Gravimetric method; Spectrophotometric method — 13 methods
- High-temperature combustion with TCD detection — 13 methods
- Inductively coupled plasma mass spectrometry (ICP-MS) — 13 methods
- Titrimetric method; Spectrophotometric method — 13 methods
- Atomic absorption spectrometry with amalgamation technique — 12 methods
- Method: sieve — 11 methods
- and 137 more
Laboratory sections (9)
- Centre for Sustainable Construction; Laboratory of Building Raw Materials and Binders — 363 methods
- Centre for Environmental Engineering — 296 methods
- Centre for Sustainable Construction; Concrete and Lightweight Composites Research Group — 88 methods
- Centre for Fire Safety and Acoustics; Construction Chemistry and Fire Safety Research Group — 84 methods
- Centre for Fire Safety and Acoustics; Glass and Acoustics Research Group — 66 methods
- Centre for Advanced Ceramics and Precast Products; Aerated Concrete and Precast Products Research Group — 63 methods
- Centre for Advanced Ceramics and Precast Products; Ceramics Research Group — 53 methods
- Centre for Sustainable Construction; Cement Research Group — 46 methods
- Centre for Refractory Materials; Refractory Materials Research Group — 26 methods
Laboratory locations
- Laboratorium Surowców i Spoiw Budowlanych — ul. Cementowa 8, 31-983 Kraków
- Centrum Zrównoważonego Budownictwa; Laboratorium Surowców i Spoiw Budowlanych —
Accreditation scope — test methods (1102)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Centre for Fire Safety and Acoustics; Glass and Acoustics Research Group | |||||
| 1 | Glass and glass products | Numerical expression of colours Range (380 - 780) nm |
Spectrophotometric method | PN-N-01252:1965 | DIN 5033:1992 cz.3 | |
| 2 | Safety building glass, toughened and laminated | Resistance to impact by a bag | PN-B-13083:1997 | ||
| 3 | Toughened safety glass panes for railway applications | Light transmittance Range (380 - 780) nm |
Spectrophotometric method | PN-B-13059:1985 | PN-B-13153:1981 | |
| 4 | Toughened safety glass panes for railway applications | Resistance to impact by a 227 g ball | PN-B-13059:1985 | PN-B-13153:1981 | ||
| 5 | Toughened safety glass panes for railway applications | Resistance to impact by a bag of side and interior glazing Range (0 - 500) g |
Gravimetric method | PN-B-13059:1985 | |
| 6 | Toughened safety glass panes for railway applications | Crack pattern Range (0 - 300) mm Linear measurements |
PN-B-13059:1985 | PN-B-13153:1981 | ||
| 7 | Glass bottles and jars | Capacity Range 5 I |
Gravimetric method | PN-O-79711:1989 | |
| 8 | Glass and glass products E | Viscosity as a function of temperature Range (lgη= 2 - 5) dPas temp. do 1500 °C Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Viscometric method | PN-ISO 7884-1 | PN-ISO 7884-2 | |
| 9 | Glass and glass products E | Mean coefficient of linear thermal expansion Range od 100 °C do temp. mięknięcia Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Dilatometric method for glass | PB-BF-16 | |
| 10 | Building glass (building glazing) E | Light transmittance Range (380 - 780) nm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Spectrophotometric method | PN-EN 410 „N” | |
| 11 | Building glass (building glazing) E | Light reflection Range (380 - 780) nm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Spectrophotometric method | PN-EN 410 „N” | |
| 12 | Building glass (building glazing) E | Total solar energy transmittance Range (300 - 2500) nm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Spectrophotometric method | PN-EN 410 „N” | |
| 13 | Building glass (building glazing) E | UV transmittance Range (280 - 380) nm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Spectrophotometric method | PN-EN 410 „N” | |
| 14 | Building glass (building glazing) E | Colour rendering Range (380 - 780) nm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Spectrophotometric method | PN-EN 410 „N” | |
| 15 | Building glass (building glazing) E | Thermal transmittance U Range (0 - 3) W/m2k Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Calculation method | PN-EN 673 „N” | |
| 16 | Building glass (building glazing) E | Emissivity Range (5 - 50) μm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Spectrophotometric method | PN-EN 12898 | |
| 17 | Insulating glass units E | Gas content in the interpane space Range (0 - 100) % Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Chromatographic method | PB-BF-07 | |
| 18 | Insulating glass units E | Rate of gas loss from the cavity between panes Range (0 - 10) μg/godz. Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Chromatographic method | PN-EN 1279-3 | PB-BF-17 | |
| 19 | Insulating glass units E | Adhesion of sealant to glass elongation (0 - 50) % stress (0 - 0,5) MPa Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Instrumental method | PN-EN 1279-4 | |
| 20 | Insulating glass units E | Thermal transmittance U Range (0 - 3) W/m2k Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Guarded hot plate method | PN-EN 674 | |
| 21 | Insulating glass units E | Thermal transmittance U Range (0 - 3) W/m2k Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Calculation method | PN-EN-673 „N” | |
| 22 | Insulating glass units E | Moisture penetration Range (0 - 200) g Range (0 - 20) g Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Gravimetric method; Karl Fischer method | PN-EN 1279-2 | PN-EN 1279-4 | PN-EN 1279-6 Zał. B p. B.4 | |
| 23 | Safety glazing for road transport vehicles E | UV transmittance Range (280 - 380) nm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Spectrophotometric method | ISO 9050 p. 3.6 | |
| 24 | Safety glazing for road transport vehicles E | Light transmittance Range (380 - 780) nm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Spectrophotometric method | Regulamin EKG ONZ NR 43 Zał. 3 p. 9.1 | |
| 25 | Safety glazing for road transport vehicles E | Total solar energy transmittance Range (300 - 2500) nm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Spectrophotometric method | ISO 9050 p. 3.5.3 | |
| 26 | Building glass, thermally toughened safety glass E | Dimensions and tolerances Range (0 - 5000) mm Linear measurements Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 12150-1 | ||
| 27 | Building glass, thermally toughened safety glass E | Character of the crack network Range (0 - 300) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Visual method and linear measurements | PN-EN 12150-1 „N” | |
| 28 | Building glass, thermally toughened safety glass E | Flexural strength Range (0 - 400) N/mm2 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 1288-3 „N” | ||
| 29 | Building glass, thermally toughened safety glass E | Resistance to pendulum impact Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 12600 „N” | ||
| 30 | Building glass, thermally toughened, heat soaked safety glass E | Dimensions Range (0 - 5000) mm Linear measurements Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 14179-1 | ||
| 31 | Building glass, thermally toughened, heat soaked safety glass E | Character of the crack network Range (0 - 300) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Visual method and linear measurements | PN-EN 14179-1 „N” | |
| 32 | Building glass, thermally toughened, heat soaked safety glass E | Flexural strength Range (0 - 400) N/mm2 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN-1288-3 „N” | ||
| 33 | Building glass, thermally toughened, heat soaked safety glass E | Resistance to pendulum impact Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN-12600 „N” | ||
| 34 | Heat strengthened building glass E | Dimensions Range (0 - 5000) mm Linear measurements Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 1863-1 | ||
| 35 | Heat strengthened building glass E | Character of the crack network Range (0 - 300) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Visual method and linear measurements | PN-EN 1863-1 „N” | |
| 36 | Heat strengthened building glass E | Flexural strength Range (0 - 300) N/mm2 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Instrumental method | PN-EN 1288-3 „N” | |
| 37 | Laminated glass and laminated safety glass E | Resistance to pendulum impact Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 12600 „N” | ||
| 38 | Laminated glass and laminated safety glass E | Resistance to high temperature Range 100 °C Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN ISO 12543-2 i 3 | PN-EN ISO 12543-4 | ||
| 39 | Laminated glass and laminated safety glass E | Resistance to moisture Range (0 - 50) °C (80 ± 5)% relative humidity Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN ISO 12543-2 i 3 | PN-EN ISO 12543-4 | ||
| 40 | Laminated glass and laminated safety glass E | Resistance to radiation Range (900 ± 100) W/m2 Range (380 - 780) nm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Spectrophotometric method | PN-EN ISO 12543-2 i 3 | PN-EN ISO 12543-4 | |
| 41 | Laminated glass and laminated safety glass E | Dimensions and finish of the edges Range (0 - 5000) mm Linear measurements Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN ISO 12543-5 | PN-EN ISO 12543-6 | ||
| 42 | Toughened safety glazing for, Railway applications E | Secondary image formation, optical distortion Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 15152 | ||
| 43 | Construction products: E - glazing - walls - external, internal doors | Airborne sound insulation Range of band centre frequencies 1/3 oct (50 - 5000) Hz Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN ISO 10140-1 „N” | PN-EN ISO 10140-2 | PN-EN ISO 10140-4 | PN-EN ISO 10140-5 | PN-EN 16703 | ||
| 44 | Building materials. Sound-absorbing materials. Objects and equipment forming interior furnishings. Sound-absorbing structures - road traffic noise reducing devices - acoustic screens | Sound absorption coefficient in a reverberation chamber Frequency range (100 - 5000) Hz Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN ISO 354:2005 z wyłączeniem pkt. 7.3.1. | ||
| 45 | Protective glazing for buildings E | Resistance to penetration by a ball with a mass of 4,11 kg. Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 356 „N” | ||
| 46 | Protective glazing for buildings E | Resistance to impact with a hammer and an axe Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 356 „N” | ||
| 47 | Safety glazing for road transport vehicles E (toughened and laminated) | Optical distortion Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Regulamin EKG ONZ nr 43 Zał. 3 p. 9.2 | ||
| 48 | Safety glazing for road transport vehicles E (toughened and laminated) | Secondary image separation Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Regulamin EKG ONZ nr 43 Zał. 3 p. 9.3 | ||
| 49 | Safety glazing for road transport vehicles E (toughened and laminated) | Character of the crack network Range (0 - 300) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Visual method and linear measurements | Regulamin EKG ONZ nr 43 Zał. 3 p. 1, Zał.4 p.2, Zał. 5 p. 2, Zał. 8 p. 4 | |
| 50 | Safety glazing for road transport vehicles E (toughened and laminated) | Resistance to impact by a ball of 2260 g mass Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Regulamin EKG ONZ nr 43 Zał. 3 p. 2.2, Zał. 6 p. 4.2 | ||
| 51 | Safety glazing for road transport vehicles E (toughened and laminated) | Resistance to impact by a ball of 227g mass Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Regulamin EKG ONZ nr 43 Zał. 3 p. 2.1, Zał. 5 p. 3.1, Zał. 6 p. 4.3, Zał. 7 p. 3, Zał. 11 p. 3 | ||
| 52 | Safety glazing for road transport vehicles E (toughened and laminated) | Resistance to impact by a dummy Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Regulamin EKG ONZ nr 43 Zał.3 p.3.1, Zał. 4 p. 3, Zał. 6 p. 3, Zał. 7 p. 3, Zał. 10 p.3, Zał. 11p. 3, Zał. 12 p. 3 | ||
| 53 | Safety glazing for road transport vehicles E (toughened and laminated) | Light transmittance Range (380 - 780) nm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Spectrophotometric method | Regulamin EKG ONZ nr 43 Zał.3 p. 9.1 | |
| 54 | Safety glazing for road transport vehicles E (toughened and laminated) | Abrasion resistance of glass Range (380 - 780) nm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Spectrophotometric method | Regulamin EKG ONZ nr 43 Zał. 3 p. 4, Zał. 6 p. 5.1, Zał. 7 p. 4.1, Zał. 9 p. 2 | |
| 55 | Safety glazing for road transport vehicles E (toughened and laminated) | Resistance to high temperature Range 100 °C Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Regulamin EKG ONZ nr 43 Zał. 3 p. 5 | ||
| 56 | Safety glazing for road transport vehicles E (toughened and laminated) | Resistance to radiation Range 1400 W/m2, (380 - 780) nm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Spectrophotometric method | Regulamin EKG ONZ nr 43 Zał. 3 p. 6 | |
| 57 | Safety glazing for road transport vehicles E (toughened and laminated) | Resistance to moisture Range (0 - 52) °C (95 ± 4)% relative humidity Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Regulamin EKG ONZ nr 43 Zał. 3 p. 7 | ||
| 58 | Glass bottles and jars E | Resistance to thermal shock Range różnica temperatur 80 °C Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises |
PN-EN ISO 7459 | ||
| 59 | Shower enclosures E | Impact resistance/fragmentation properties Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises |
Visual and counting method | PN-EN 14428 | |
| 60 | Shower enclosures E | Resistance of plastic sheets to impact by a bag of 45 kg mass Range (0 - 1500) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises |
Method: linear measurements | PN-EN 14428 | |
| 61 | Shower enclosures E | Resistance to chemicals and staining Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises |
Visual method | PN-EN 14428 | |
| 62 | Shower enclosures E | Resistance to wetting and drying cycles Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises |
Visual method | PN-EN 14428 | |
| 63 | Shower enclosures E | Reliability Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises |
PN-EN 14428 | ||
| 64 | Shower enclosures E | Stability Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises |
PN-EN 14428 | ||
| 65 | Shower enclosures E | Cabin tightness Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises |
Visual method | PN-EN 14428 | |
| 66 | Non-loadbearing walls E | Fire integrity, fire insulation flame stability ignition of the cotton pad holes and cracks mean temperature rise maximum temperature rise deflection Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Tests performed at and away from the laboratory's premises |
PN-EN 1363-1 | PN-EN 1364-1 | ||
| Centre for Fire Safety and Acoustics; Construction Chemistry and Fire Safety Research Group | |||||
| 67 | External walls E | Temperature value at the measuring points on the lines L1 and L2, Burning or smouldering on the lines L1 and L2, Occurrence of burning waste, Burning after the time of the test Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-B-02867 BS 8414 | ||
| 68 | Construction products excluding floors E | Heat release: FIGRA, THR 600s Smoke production: SMOGRA, TSP600s Lateral flame spread: LFS Dripping and falling off under the influence of fire Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 13823 „N” | ||
| 69 | Floorings and floor coverings E | Critical heat flux, Heat flux at 30 minutes, Smoke emission, Flame spread distance, Flame extinguishment time Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN ISO 9239-1 „N” | ||
| 70 | External thermal insulation composite systems | Resistance to hard body impact Range (3 - 10) J Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-B-10027:1993 | ||
| 71 | Adhesive and rendering compounds, adhesive and rendering mortars for external thermal insulation systems | Bulk density Range (1,0 - 3,0) g/cm3 Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Gravimetric method | PN-B-04500:1985 p.3.5 | |
| 72 | Tile adhesives | Tensile strength Force range (0,1 - 15) kN Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: pull-off | PN-EN 1348:2008 „N” | |
| 73 | Tile adhesives | Slip Range (0 - 20,0) mm Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 1308:2008 | ||
| 74 | Tile adhesives | Open time Force range (0,1 - 15) kN Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: pull-off | PN-EN 1346:2008 | |
| 75 | Tile adhesives | Transverse deformation Range (0 - 20,0) mm Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 12002:2010 | ||
| 76 | Tile adhesives | Determination of shear strength Force range (0,05 – 12) kN Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 1324:2008 | PN-EN 12003:2010 | ||
| 77 | Ceramic tiles | Tensile strength Force range (0,1 - 15) kN Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: pull-off | PN-EN 1348:2008 | |
| 78 | Ceramic tiles | Determination of shear strength Force range (0,05 - 12) kN Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 1324:2008 | PN-EN 12003:2010 | ||
| 79 | Non-loadbearing walls | Fire resistance Fire integrity, fire insulation flame stability ignition of the cotton pad holes and cracks mean temperature rise maximum temperature rise deflection Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 1364-1:2015-08 „N” | PN-EN 1364-1:2001 „N” | PN-EN 1363-1:2001 | PN-EN 1363-1:2012 | PN-EN 1363-1:2020-07 | PN-EN 1363-2:2001 z wył. P.7 | ||
| 80 | Loadbearing walls | Loadbearing capacity R, integrity, insulation, radiation, resistance to mechanical impact deformation C deformation rate dC/dt flame persistence holes and cracks ignition of the cotton wool pad mean temperature rise maximum temperature rise irradiance effect of mechanical action deformation Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 1365-1:2013-08 „N” | PN-EN 1365-1:2001 „N” | PN-EN 1363-1:2012 | PN-EN 1363-1:2020-07 | PN-EN 1363-1:2001 z wył. P.7 | ||
| 81 | Fire doors and shutters | Fire resistance Fire resistance fire insulation, min fire integrity, min flame stability irradiance at a single point Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 1634-1+A1:2018-03 „N” | PN-EN 1634-1+A1:2009 „N” | PN-EN 1363-1:2001 | PN-EN 1363-1:2012 | PN-EN 1363-1:2020-07 | PN-EN 1363-1:2001 z wył. P.7 | ||
| 82 | Gypsum binders E | Grading Range (0 - 100,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Sieve analysis method | PN-EN 13279-2 | |
| 83 | Gypsum binders E | Water : binder ratio Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Pouring method | PN-EN 13279-2 | |
| 84 | Gypsum binders E | Setting time Range (1 - 100) min. Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Knife method | PN-EN 13279-2 | |
| 85 | Gypsum binders and gypsum mortars (plasters, skim coats, fillers, gypsum filling compounds) E | Flexural strength Force range (0,2 - 10) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 13279-2 | ||
| 86 | Gypsum binders and gypsum mortars (plasters, skim coats, fillers, gypsum filling compounds) E | Compressive strength Force range (0,2 – 200) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 13279-2 | ||
| 87 | Gypsum binders and gypsum mortars (plasters, skim coats, fillers, gypsum filling compounds) E | Surface hardness Range (2,0 - 30,0) N/mm2 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 13279-2 | ||
| 88 | Gypsum mortars (plasters, skim coats, fillers, gypsum filling compounds) E | Setting time Range (3 - 480) min. Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Vicat method | PN-EN 13279-2 | |
| 89 | Gypsum mortars (plasters, skim coats, fillers, gypsum filling compounds) E | Grading Range (0 - 100,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Sieve analysis method | PN-EN 13279-2 | |
| 90 | Gypsum mortars (plasters, skim coats, fillers, gypsum filling compounds) E | Water : binder ratio Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flow table method | PN-EN 13279-2 | |
| 91 | Gypsum mortars (plasters, skim coats, fillers, gypsum filling compounds) E | Adhesion to the substrate Force range (0,1 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: pull-off | PN-EN 13279-2 | |
| 92 | Jointing materials for gypsum plasterboards E | Particle size distribution Range (0 -100)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Sieve analysis method | PN-EN 13963 | |
| 93 | Jointing materials for gypsum plasterboards E | Setting time Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Vicat method | PN-EN 13963 | |
| 94 | Jointing materials for gypsum plasterboards E | No cracks Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 13963 | ||
| 95 | Jointing materials for gypsum plasterboards E | Adhesion/cohesion Force range (0,1 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Pull-off method | PN-EN 13963 | |
| 96 | Jointing materials for gypsum plasterboards E | Flexural strength Range (0,05 - 5) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Stretching method | PN-EN 13963 | |
| 97 | Jointing materials for gypsum plasterboards E | Flexural strength Range (0,05 - 2) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Bending method | PN-EN 13963 | |
| 98 | Gypsum adhesives for gypsum boards E | Adhesion to the substrate Force range (0,1 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: pull-off | PN-EN 12860 | |
| 99 | Ceramic tiles E | Tensile strength Force range (0,1 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: pull-off | EN 12004-2 | |
| 100 | Ceramic tiles E | Determination of shear strength Force range (0,05 - 12) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
EN 12004-2 | ||
| 101 | Tile adhesives E | Tensile strength Force range (0,1 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: pull-off | EN 12004-2 | |
| 102 | Tile adhesives E | Slip Range (0 - 20,0) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
EN 12004-2 | ||
| 103 | Tile adhesives E | Open time Force range (0,1 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: pull-off | EN 12004-2 | |
| 104 | Tile adhesives E | Transverse deformation Range (0 - 20,0) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
EN 12004-2 | ||
| 105 | Tile adhesives E | Determination of shear strength Force range (0,05 - 12) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
EN 12004-2 | ||
| 106 | Thermal insulation materials E | Short-term water absorption by partial immersion of the specimen Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Gravimetric method | PN-EN 1609 „N” | PN-EN ISO 29767 | |
| 107 | Thermal insulation materials E | Water absorption by long-term immersion of the specimen Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Gravimetric method | PN-EN 12087 „N” | PN-EN ISO 16535 | |
| 108 | Thermal insulation materials E | Compressive strength, Range up to (0,025 - 10) kN compression test Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 826 „N” | PN-EN ISO 29469 | ||
| 109 | Thermal insulation materials E | Tensile strength Range (0,025 - 10) kN tensile test Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 1607 | ||
| 110 | Thermal insulation materials E | Behaviour in bending Range (0,025 - 10) kN Bend test Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 12089 | ||
| 111 | Thermal insulation materials E | Water vapour transmission Range (0 - 10) m Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Gravimetric method | PN-EN 12086 | |
| 112 | Thermal insulation materials E | Dimensions (length, width) Range (do 2000) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 822 | PN-EN ISO 29465 | ||
| 113 | Thermal insulation materials E | Thickness Range (0,0 - 300) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 823 | PN-EN ISO 29466 | ||
| 114 | Thermal insulation materials E | Squareness Range (0,05 - 10) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 824 | ||
| 115 | Thermal insulation materials E | Flatness Range (0,05 - 10) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 825 | PN-EN ISO 29468 | ||
| 116 | Priming solutions, façade paints for external thermal insulation systems E | Density Range (1,0 - 2,5) g/cm3 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Pycnometric method | PN-EN ISO 2811-1 ETAG 004 Europejskie Dokumenty Oceny | |
| 117 | Priming solutions, façade paints for external thermal insulation systems E | External appearance of the product as supplied Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN ISO 1513 | ||
| 118 | Adhesive and rendering mortars for external thermal insulation systems E | Bulk density Range (0,5 - 2,5) g/cm3 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Gravimetric method | PN-EN 1097-3 | |
| 119 | Adhesive and rendering compounds, adhesive and rendering mortars for external thermal insulation systems E | Bulk density Range (1,0 - 3,0) g/cm3 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Gravimetric method | ETAG 004 Europejskie Dokumenty Oceny | |
| 120 | Adhesive mortars and compounds for external thermal insulation systems E | Adhesion to the substrate Force range (0,1 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: pull-off | ETAG 004 Europejskie Dokumenty Oceny | |
| 121 | Adhesive mortars and compounds for external thermal insulation systems E | Adhesion to the thermal insulation product Force range (0,025 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: pull-off | ETAG 004 Europejskie Dokumenty Oceny | |
| 122 | Adhesive mortars and compounds for external thermal insulation systems E | Shrinkage Range (0,1 - 1,5) mm/m Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Graff-Kaufman method | ETAG 004 Europejskie Dokumenty Oceny | |
| 123 | Adhesive mortars and compounds for external thermal insulation systems E | Static modulus of elasticity, tear strength Force range (0,05 - 1) kN elongation at fracture Range (0,1 - 25) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
ETAG 004 Europejskie Dokumenty Oceny | ||
| 124 | Adhesive mortars and compounds for external thermal insulation systems E | Apparent density Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
ETAG 004 Europejskie Dokumenty Oceny | ||
| 125 | External thermal insulation composite systems E | Watertightness Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
ETAG 004 Europejskie Dokumenty Oceny | ||
| 126 | External thermal insulation composite systems E | Water absorption Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | ETAG 004 Europejskie Dokumenty Oceny | |
| 127 | External thermal insulation composite systems E | Resistance to hard body impact Range (3 - 10) J Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
ETAG 004 Europejskie Dokumenty Oceny | ||
| 128 | External thermal insulation composite systems E | Resistance to puncture Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: Perfotest | ETAG 004 Europejskie Dokumenty Oceny | |
| 129 | External thermal insulation composite systems E | Water vapour permeability (water vapour diffusion resistance) Range (0 - 3,0) m Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Free films method – gravimetric method | ETAG 004 Europejskie Dokumenty Oceny | PN-EN ISO 7783 | |
| 130 | External thermal insulation composite systems E | Water vapour transmission properties Range (0 - 3,0) m Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 12086 | |
| 131 | External thermal insulation composite systems E | Adhesion of the reinforced layer to the thermal insulation product Force range (0,025 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: pull-off | ETAG 004 Europejskie Dokumenty Oceny | |
| 132 | External thermal insulation composite systems E | Adhesion after ageing Force range (0,025 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: pull-off | ETAG 004 Europejskie Dokumenty Oceny | |
| 133 | Fasteners for fixing thermal insulation E | Resistance to wind load consisting in pull-through of fasteners through the thermal insulation product, Range up to 10 kN tensile test Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
ETAG 004 Europejskie Dokumenty Oceny | ||
| 134 | Gypsum adhesives for composite panels used in thermal and acoustic insulation and for gypsum plasterboards E | Usage time Range (3 - 360) min. Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 14496 | ||
| 135 | Gypsum adhesives for composite panels used in thermal and acoustic insulation and for gypsum plasterboards E | Adhesion to expanded polystyrene Force range (0,1 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: pull-off | PN-EN 14496 | |
| 136 | Reinforcing meshes/fabrics for thermal insulation systems E | Mass per unit area Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
ETAG 004 | ||
| 137 | Reinforcing meshes/fabrics for thermal insulation systems E | Size (dimensions) of mesh and number of fibres Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
ETAG 004 | ||
| 138 | Reinforcing meshes/fabrics for thermal insulation systems E | Breaking strength and elongation Range (2 - 100) N/mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
ETAG 004 | ||
| 139 | Reinforcing meshes/fabrics for thermal insulation systems E | Mesh dimensions Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Europejskie Dokumenty Oceny | ||
| 140 | Reinforcing meshes/fabrics for thermal insulation systems E | Mesh width Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Europejskie Dokumenty Oceny | ||
| 141 | Reinforcing meshes/fabrics for thermal insulation systems E | Mass per unit area Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Europejskie Dokumenty Oceny | ||
| 142 | Sealants E | Initial adhesion Force range (0,1 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: pull-off | PN-EN 14891 | |
| 143 | Sealants E | Adhesion after contact with water Force range (0,1 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: pull-off | PN-EN 14891 p.A.6.4 | |
| 144 | Sealants E | Adhesion after thermal ageing Force range (0,1 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: pull-off | PN-EN 14891 | |
| 145 | Sealants E | Adhesion after freeze-thaw cycles Force range (0,1 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: pull-off | PN-EN 14891 | |
| 146 | Sealants E | Adhesion after exposure to lime water Force range (0,1 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: pull-off | PN-EN 14891 | |
| 147 | Sealants E | Adhesion after exposure to chlorinated water Force range (0,1 - 15) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: pull-off | PN-EN 14891 p. A.6.8 | |
| 148 | Sealants E | Crack bridging ability under standardized conditions Range (0,1 - 25,0) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 14891 | ||
| 149 | Construction products (e.g. insulating materials, flooring materials, adhesives, plasters, mortars, compounds, etc.) E | Flaming combustion time, Relative mass loss, Temperature rise Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN ISO 1182 „N” | ||
| 150 | Construction products E | Occurrence of inflammation, Spread of flames, Occurrence of flaming droplets and solid debris causing inflammation of the filter paper Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN ISO 11925-2 „N” | ||
| Centre for Sustainable Construction; Laboratory of Building Raw Materials and Binders | |||||
| 151 | Cement constituents | Calcium oxide CaO content Range (0,01 - 65,0)% |
Titrimetric method | PN-H-04156-07:1981 | |
| 152 | Cement constituents | Magnesium oxide MgO content Range (0,02 - 20,0)% |
Titrimetric method | PN-H-04156-08:1981 | |
| 153 | Cement constituents | Manganese content Range (0,005 - 2,0)% |
Spectrophotometric method | PN-G-04528-00:1977 | PN-G-04528-09:1979 | |
| 154 | Cement constituents | Phosphorus pentoxide P2O5 content Range (0,001 - 20,0)% |
Spectrophotometric method | PN-G-04528-11:1986 | PN-H-04159-07:1983 | |
| 155 | Limestone | Calcium oxide CaO content Range (0,01 - 65,0)% |
Titrimetric method | PN-H-04156-07:1981 | |
| 156 | Limestone | Magnesium oxide MgO content Range (0,02 - 20,0)% |
Titrimetric method | PN-H-04156-08:1981 | |
| 157 | Limestone | Manganese content Range (0,005 - 2,0)% |
Spectrophotometric method | PN-G-04528-00:1977 | PN-G-04528-09:1979 | |
| 158 | Limestone | Phosphorus pentoxide P2O5 content Range (0,001 - 20,0)% |
Spectrophotometric method | PN-G-04528-11:1986 | PN-H-04159-07:1983 | |
| 159 | Ashes | Loss on ignition content Range (0,05 - 40,0)% |
Gravimetric method | PN-G-04528-02:1977 | |
| 160 | Ashes | Sulphuric anhydride SO3 content Range (0,01 - 15,0) % |
Gravimetric method | PN-G-04528-12:1977 | |
| 161 | Ashes | Silicon dioxide SiO2 content Range (0,10 - 80,0)% Range (0,005 - 0,50)% |
Gravimetric method; Spectrophotometric method | PN-G-04528-03:1977 | |
| 162 | Ashes | Iron (III) oxide Fe2O3 content Range (0,15 - 25,0)% Range (0,005 - 0,50)% |
Titrimetric method; Spectrophotometric method | PN-G-04528-05:1978 | |
| 163 | Ashes | Aluminium oxide Al2O3 content Range (0,05 - 30,0)% |
Titrimetric method | PN-G-04528-04:1977 | |
| 164 | Ashes | Calcium oxide CaO content Range (0,01 - 25,0)% |
Titrimetric method | PN-G-04528-06:1977 | |
| 165 | Ashes | Magnesium oxide MgO content Range (0,02 - 10,0)% |
Titrimetric method | PN-G-04528-07:1977 | |
| 166 | Ashes | Manganese content Range (0,005 - 5,0)% |
Spectrophotometric method | PN-G-04528-09:1979 | |
| 167 | Ashes | Phosphorus pentoxide P2O5 content Range (0,001 - 20,0)% |
Spectrophotometric method | PN-G-04528-11:1986 | |
| 168 | Glass | Silicon dioxide SiO2 content Range (5,0 - 95,0)% |
Gravimetric and spectrophotometric method | PN-B-13160:1985 | |
| 169 | Glass | Barium oxide content BaO Range (0,2 - 5,0)% |
Gravimetric method | PN-B-13160:1985 | |
| 170 | Glass | Aluminium oxide Al2O3 content Range (0,2 - 15,0)% |
Titrimetric method | PN-B-13160:1985 | |
| 171 | Glass | Calcium oxide CaO content Range (0,5 - 15,0)% |
Titrimetric method | PN-B-13160:1985 | |
| 172 | Glass | Magnesium oxide MgO content Range (0,3 - 10)% |
Titrimetric method | PN-B-13160:1985 | |
| 173 | Glass | Iron oxide Fe2O3 content Range (0,01 - 0,5)% |
Spectrophotometric method | PN-B-13160:1985 | |
| 174 | Glass | Titanium oxide TiO2 content Range (0,005 - 0,1)% |
Spectrophotometric method | PN-B-13160:1985 | |
| 175 | Glass | Boron oxide content B2O3 Range (0,5 - 20,0)% |
Titrimetric method | PN-B-13160:1985 | |
| 176 | Glass | Lead oxide content PbO Range (0,5 - 30,0)% |
Titrimetric method | PN-B-13160:1985 | |
| 177 | Glass | Zinc oxide content ZnO Range (0,5 - 5,0)% |
Titrimetric method | PN-B-13160:1985 | |
| 178 | Glass | Alkali content Na2O and K2O Range (0,02 - 20,0)% Range (0,02 - 20,0)% |
Flame photometry method; Flame atomic absorption spectrometry FAAS | PN-B-13160:1985 | |
| 179 | Glass | Sulphuric anhydride SO3 content Range (0,05 - 2,0)% |
Gravimetric method | PN-B-13160:1985 | |
| 180 | Glass | Loss on ignition content Range (0,05 - 1,0)% |
Gravimetric method | PN-B-13160:1985 | |
| 181 | Glass sand | Moisture content Range (0,1 - 20,0)% |
Gravimetric method | BN-80/6811-01 | |
| 182 | Glass sand | Loss on ignition content Range (0,005 - 3,0)% |
Gravimetric method | BN-80/6811-01 | |
| 183 | Glass sand | Silicon dioxide SiO2 content Range (90,0 - 100,0)% |
Gravimetric method | BN-80/6811-01 | |
| 184 | Glass sand | Titanium oxide TiO2 content Range (0,002 - 0,2)% |
Spectrophotometric method | BN-80/6811-01 | |
| 185 | Glass sand | Iron oxide Fe2O3 content Range (0,005 - 0,2)% |
Spectrophotometric method | BN-80/6811-01 | |
| 186 | Glass sand | Aluminium oxide Al2O3 content Range (0,5 - 6,0)% Range (0,001 - 0,5)% |
Titrimetric method; Spectrophotometric method | BN-80/6811-01 | |
| 187 | Glass sand | Calcium oxide CaO content Range (0,2 - 2,0)% |
Titrimetric method | BN-80/6811-01 | |
| 188 | Glass sand | Alkali content Na2O and K2O Range (0,002 - 2,0)% |
Flame photometry method | BN-80/6811-01 | |
| 189 | Glass sand | Sulphuric anhydride SO3 content Range (0,01 - 1,0)% |
Gravimetric method | BN-80/6811-01 | |
| 190 | Kaolins and clays | Loss on ignition content Range (0,05 - 5,0)% |
Gravimetric method, | BN-85/7011-23 | |
| 191 | Kaolins and clays | Silicon dioxide SiO2 content Range (0,05 - 80,0)% |
Gravimetric and spectrophotometric method | BN-85/7011-23 | |
| 192 | Kaolins and clays | Aluminium oxide Al2O3 content Range (0,5 - 30,0)% |
Titrimetric method | BN-85/7011-23 | |
| 193 | Kaolins and clays | Iron oxide Fe2O3 content Range (0,005 - 1,0)% |
Spectrophotometric method, Range (1,0 - 20,0)%; Titrimetric method | BN-85/7011-23 | |
| 194 | Kaolins and clays | Titanium oxide TiO2 content Range (0,001 - 1,0)% |
Spectrophotometric method | BN-85/7011-23 | |
| 195 | Kaolins and clays | Calcium oxide CaO content Range (0,5 - 25,0)% |
Titrimetric method | BN-85/7011-23 | |
| 196 | Kaolins and clays | Magnesium oxide MgO content Range (0,5 - 25,0)% |
Titrimetric method | BN-85/7011-23 | |
| 197 | Kaolins and clays | Alkali content Na2O and K2O Range (0,05 - 15,0)% |
Flame photometry method and flame atomic absorption spectrometry method FAAS | BN-85/7011-23 | |
| 198 | Kaolins and clays | Sulphuric anhydride SO3 content Range (0,2 - 5,0)% |
Gravimetric method | BN-85/7011-23 | |
| 199 | Magnesites and dolomites | Loss on ignition content Range (1,0 - 52,0)% |
Gravimetric method | PN-H-04156-01:1981 | |
| 200 | Magnesites and dolomites | Silicon dioxide SiO2 content Range (1,0 - 25,0)% |
Gravimetric method | PN-H-04156-02:1992 | |
| 201 | Magnesites and dolomites | Iron oxide Fe2O3 content Range (0,01 - 2,5)% Range (2,0 - 10,0)% |
Spectrophotometric method; Titrimetric method | PN-H-04156-03:1992 | |
| 202 | Magnesites and dolomites | Aluminium oxide Al2O3 content Range (1,0 - 5,0)% |
Titrimetric method | PN-H-04156-04:1981 | |
| 203 | Magnesites and dolomites | Calcium oxide CaO content Range (0,5 - 60,0)% |
Titrimetric method | PN-H-04156-07:1981 | |
| 204 | Magnesites and dolomites | Magnesium oxide MgO content Range (15,0 - 99,0)% |
Titrimetric method | PN-H-04156-08:1981 | |
| 205 | Magnesites and dolomites | Alkali content Na2O and K2O Range (0,04 - 2,8)% |
Flame photometry method | PN-H-04156-09:1981 | |
| 206 | Cements (common cements, special cements and others) E | Compressive strength Force range (2,4 - 240,0) kN Flexural strength Force range (0,2 - 10,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 196-1 | ||
| 207 | Cements (common cements, special cements and others) E | Standard consistence Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 196-3 | |
| 208 | Cements (common cements, special cements and others) E | Setting times Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 196-3 | |
| 209 | Cements (common cements, special cements and others) E | Soundness Le Chatelier Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a ring | PN-EN 196-3 | |
| 210 | Cements (common cements, special cements and others) E | Density Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Le Chatelier flask, using a helium pycnometer | PB/LP-15 | |
| 211 | Cements (common cements, special cements and others) E | Specific surface area Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: air permeability (Blaine) | PN-EN 196-6 | |
| 212 | Cements (common cements, special cements and others) E | Degree of grinding Range (0,063 - 1,00) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: sieve | PN-EN 196-6 | PN ISO 2591-1 | |
| 213 | Cements (common cements, special cements and others) E | Air content in mortars Range (0 - 25)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a pressure apparatus | PN-EN 413-2 | |
| 214 | Cements (common cements, special cements and others) E | Shrinkage Range (0,00 - 5,00) mm/m Kauffman Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Graff apparatus | PB/LP-20 | |
| 215 | Cements (common cements, special cements and others) E | Bulk density Range (0,1 - 5,0) kg/dm3 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 459-2 | |
| 216 | Cements (common cements, special cements and others) E | Sampling Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 196-7 | ||
| 217 | Calcium aluminate cements E | Compressive strength Force range (2,4 - 240,0) kN Flexural strength Force range (0,2 - 10,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 14647 | PN-EN 196-1 | ||
| 218 | Calcium aluminate cements E | Consistency Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 14647 | PN-EN 196-3 | |
| 219 | Calcium aluminate cements E | Setting times Range (10 - 2000) min. Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 14647 | PN-EN 196-3 | |
| 220 | Calcium aluminate cements E | Density Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Le Chatelier flask, using a helium pycnometer | PB/LP-15 | |
| 221 | Calcium aluminate cements E | Specific surface area Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: air permeability (Blaine) | PN-EN 196-6 | |
| 222 | Calcium aluminate cements E | Fineness, Range (0,063 - 1,00) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: sieve | PN-EN 196-6 | PN ISO 2591-1 | |
| 223 | Calcium aluminate cements E | Sampling Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 196-7 | ||
| 224 | Masonry cements E | Compressive strength Force range (2,4 - 130,0) kN Flexural strength Force range (0,2 - 5,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 413-1 | PN-EN 196-1 | ||
| 225 | Masonry cements E | Standard consistence Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 413-2 | PN-EN 196-3 | |
| 226 | Masonry cements E | Setting times Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 413-2 | PN-EN 196-3 | |
| 227 | Masonry cements E | Soundness Le Chatelier Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a ring | PN-EN 196-3 | |
| 228 | Masonry cements E | Density Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Le Chatelier flask, using a helium pycnometer | PB/LP-15 | |
| 229 | Masonry cements E | Specific surface area Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: air permeability (Blaine) | PN-EN 196-6 | |
| 230 | Masonry cements E | Consistence of standard mortar Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a plunger apparatus using a flow table | PN-EN 413-2 | |
| 231 | Masonry cements E | Water retention Range (0,0 - 100,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using filter paper | PN-EN 413-2 | |
| 232 | Masonry cements E | Sampling Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 196-7 | ||
| 233 | Masonry cements E | Air content Range (0,1 - 25,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: pressure | PN-EN 413-2 | |
| 234 | Masonry cements E | Fineness, Fraction above 0,09 mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: sieve | PN-EN 413-1 | PN-EN 196-6 | PN ISO 2591-1 | |
| 235 | Building lime E | Compressive strength Force range (2,4 - 50,0) kN Flexural strength Force range (0,2 - 4,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 459-2 | PN-EN 196-1 | ||
| 236 | Building lime E | Degree of grinding Range (0,063 - 1,00) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: sieve | PN-EN 196-6 | PN ISO 2591-1 | PN-EN 459-2 | |
| 237 | Building lime E | Bulk density Range (0,1 - 5,0) kg/dm3 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 459-2 | |
| 238 | Building lime E | Soundness Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: based on changes in the dimensions of the pellet | PN-EN 459-2 | |
| 239 | Building lime E | Soundness Le Chatelier Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a ring | PN-EN 459-2 | PN-EN 196-3 | |
| 240 | Building lime E | Soundness Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: based on observation of the cake surface; Method: based on observation of the disc surface | PN-EN 459-2 | |
| 241 | Building lime E | Consistency Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 459-2 | |
| 242 | Building lime E | Setting times Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 459-2 | |
| 243 | Building lime E | Reactivity Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a Dewar vessel | PN-EN 459-2 | |
| 244 | Building lime E | Capacity Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using an extinguishing container | PN-EN 459-2 | |
| 245 | Building lime E | Consistence of standard mortar Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a flow table and a plunger apparatus | PN-EN 459-2 | |
| 246 | Building lime E | Water retention Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using filter paper | PN-EN 459-2 | |
| 247 | Building lime E | Air content Range (0,1 - 25,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: pressure | PN-EN 459-2 | |
| 248 | Building lime E | Density Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Le Chatelier flask, using a helium pycnometer | PB/LP-15 | |
| 249 | Siliceous fly ash E | Compressive strength (for the activity index) Force range (2,4 - 240,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 450-1 | PN-EN 196-1 | ||
| 250 | Siliceous fly ash E | Flexural strength Force range (0,2 - 10,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 196-1 | ||
| 251 | Siliceous fly ash E | Standard consistence Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 450-1 | PN-EN 196-3 | |
| 252 | Siliceous fly ash E | Setting times Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 450-1 | PN-EN 196-3 | |
| 253 | Siliceous fly ash E | Soundness Le Chatelier Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a ring | PN-EN 450-1 | PN-EN 196-3 | |
| 254 | Siliceous fly ash E | Density Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Le Chatelier flask, using a helium pycnometer | PB/LP-15 | |
| 255 | Siliceous fly ash E | Water demand Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a flow table | PN-EN 450-1 Załącznik B | |
| 256 | Siliceous fly ash E | Fineness (fineness of grind), Fraction above 0,045 mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: sieve | PN-EN 451-2 | |
| 257 | Siliceous fly ash E | Sampling Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 196-7 | ||
| 258 | Fillers (ash, slag-ash, cement, sand) E | Particle density Range (1,5 - 4,0) Mg/m3 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: pycnometric | PN-EN 1097-7 | |
| 259 | Calcareous fly ash E | Fineness, Fraction above 0,04 mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: sieve | PN-EN 197-1 | |
| 260 | Calcareous fly ash E | Compressive strength Force range (1,0 - 30,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 196-1 | PN-EN 197-1 | ||
| 261 | Calcareous fly ash E | Flexural strength Force range (0,2 - 10,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 196-1 | ||
| 262 | Calcareous fly ash E | Standard consistence Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 196-3 | PN-EN 197-1 | |
| 263 | Calcareous fly ash E | Soundness Le Chatelier Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a ring | PN-EN 196-3 | PN-EN 197-1 | |
| 264 | Calcareous fly ash E | Density Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Le Chatelier flask, using a helium pycnometer | PB/LP-15 | |
| 265 | Slags E | Compressive strength Force range (2,4 - 240,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 15167-1 | PN-EN 196-1 | ||
| 266 | Slags E | Flexural strength Force range (0,2 - 10,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 196-1 | ||
| 267 | Slags E | Consistency Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 15167-1 | PN-EN 196-3 | |
| 268 | Slags E | Setting times Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 15167-1 | PN-EN 196-3 | |
| 269 | Slags E | Density Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Le Chatelier flask, using a helium pycnometer | PB/LP-15 | |
| 270 | Slags E | Specific surface area Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: air permeability (Blaine) | PN-EN 196-6 | PN-EN 15167-1 | |
| 271 | Slags E | Degree of grinding Range (0,063 - 1,00) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: sieve | PN-EN 196-6 | PN ISO 2591-1 | |
| 272 | Slags E | Sampling Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 196-7 | ||
| 273 | Silica fume E | Compressive strength (for the activity index) Force range (2,4 - 240,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 13263-1 | PN-EN 196-1 | PN-EN 413-2 | ||
| 274 | Silica fume E | Flexural strength Force range (0,2 - 10,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 196-1 | ||
| 275 | Silica fume E | Consistence of standard mortar Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a flow table | PN-EN 13263-1 | PN-EN 413-2 | |
| 276 | Silica fume E | Density Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Le Chatelier flask, using a helium pycnometer | PB/LP-15 | |
| 277 | Silica fume E | Sampling Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 196-7 | ||
| 278 | Hydraulic binders E | Compressive strength Force range (2,4 - 130,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 15368 | PN-EN 196-1 | PN-EN 459-2 | ||
| 279 | Hydraulic binders E | Flexural strength Force range (0,2 - 5,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 196-1 | ||
| 280 | Hydraulic binders E | Standard consistence Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 413-2 | PN-EN 196-3 | |
| 281 | Hydraulic binders E | Setting times Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 413-2 | PN-EN 196-3 | |
| 282 | Hydraulic binders E | Soundness Le Chatelier Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a ring | PN-EN 196-3 | |
| 283 | Hydraulic binders E | Bulk density Range (0,1 - 5,0) kg/dm3 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 459-2 | |
| 284 | Hydraulic binders E | Degree of grinding Range (0,063 - 1,00) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: sieve | PN-EN 196-6 | PN ISO 2591-1 | |
| 285 | Hydraulic binders E | Consistence of standard mortar Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a flow table using a plunger apparatus | PN-EN 413-2 | |
| 286 | Hydraulic road binders E | Compressive strength Force range (2,4 - 240,0) kN Flexural strength Force range (0,2 - 10,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 13282-1 | PN-EN 13282-2 | PN-EN 196-1 | ||
| 287 | Hydraulic road binders E | Setting times Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 13282-1 | PN-EN 13282-2 | PN-EN 196-3 | |
| 288 | Hydraulic road binders E | Soundness Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Le Chatelier ring based on observation of the cake surface | PN-EN 13282-1 | PN-EN 13282-2 | PN-EN 196-3 | PN-EN 459-2 | |
| 289 | Hydraulic road binders E | Degree of grinding Range (0,063 - 1,00) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: sieve | PN-EN 13282-1 | PN-EN 13282-2 | PN-EN 196-6 | PN ISO 2591-1 | |
| 290 | Hydraulic road binders E | Density Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Le Chatelier flask, using a helium pycnometer | PB/LP-15 | |
| 291 | Hydraulic road binders E | Specific surface area Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: air permeability (Blaine) | PN-EN 196-6 | |
| 292 | CEN standard sand E | Compressive strength Force range (2,4 - 240,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 196-1 | ||
| 293 | CEN standard sand E | Grading Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Sieve method | PN-EN 196-1 | |
| 294 | Sludges, suspensions E | Bulk density Range (10,0 - 1000,0) cm3 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PB/LP-23 | |
| 295 | Cement, Building lime, Construction adhesives, Gypsum binders, Building mortars, Hydraulic binders and other building materials E | Sampling for consumer tests Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PB/LP-25 | ||
| 296 | Ground limestone E | Bulk density Range (0,1 - 5,0) kg/dm3 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 459-2 | |
| 297 | Ground limestone E | Density Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Le Chatelier flask, using a helium pycnometer | PB/LP-15 | |
| 298 | Ground limestone E | Specific surface area Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: air permeability (Blaine) | PN-EN 196-6 | |
| 299 | Ground limestone E | Degree of grinding Range (0,063 - 1,00) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: sieve | PN-EN 196-6 | PN ISO 2591-1 | |
| 300 | Clinker E | Bulk density (litre weight) Range (0,1 - 5,0) kg/dm3 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 459-2 | |
| 301 | Adhesive and rendering compounds and mortars E | Determination of particle size distribution Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: sieve | ETAG 004 Europejskie Dokumenty Oceny | |
| 302 | Building gypsum E | Degree of whiteness Range (50,0 - 100,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a spectrophotometer | VGB M 701 E | |
| 303 | White cement and plasters E | Degree of whiteness Range (50,0 - 100,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a spectrophotometer | PB/LP-26 | |
| 304 | Clinker for white cement production, building lime, limestone, glass sands, titanium white, zinc white E | Degree of whiteness Range (50,0 - 100,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a spectrophotometer | PB/LP-26 | |
| 305 | Common cements and special cements, cements, cementitious binders E | Loss on ignition content Range (0,05 – 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 306 | Common cements and special cements, cements, cementitious binders E | Content of insoluble matter (NR) Range (0,05 - 80,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | PN-B-19707 | |
| 307 | Common cements and special cements, cements, cementitious binders E | Sulphuric anhydride SO3 content Range (0,01 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 308 | Common cements and special cements, cements, cementitious binders E | Chloride Cl ̅ content Range (0,0005 - 0,50)% Range (0,005 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Potentiometric method; Volhard titrimetric method | PN-EN 196-2 | |
| 309 | Common cements and special cements, cements, cementitious binders E | Silicon dioxide SiO2 content Range (0,10 - 99,9)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Spectrophotometric method | PB/LC-5 PB/LC-6 | PN-EN 196-2 | |
| 310 | Common cements and special cements, cements, cementitious binders E | Iron (III) oxide Fe2O3 content Range (0,15 - 5,0)% Range (0,005 - 2,5)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method; Spectrophotometric method | PN-EN 196-2 | |
| 311 | Common cements and special cements, cements, cementitious binders E | Aluminium oxide Al2O3 content Range (0,05 - 85,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 312 | Common cements and special cements, cements, cementitious binders E | C3A content (calculated), C4AF content (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
BN-62/6731-03 | ||
| 313 | Common cements and special cements, cements, cementitious binders E | Calcium oxide CaO content Range (0,01 - 65,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 314 | Common cements and special cements, cements, cementitious binders E | Magnesium oxide MgO content Range (0,02 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 315 | Common cements and special cements, cements, cementitious binders E | Carbon dioxide CO2 content Range (0,05 - 25,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 316 | Common cements and special cements, cements, cementitious binders E | Alkali content (Na2O, K2O) Range (0,02 - 5,0)% Range (0,001 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame photometry method; Flame atomic absorption spectrometry FAAS | PB/LC-12 | PN-EN 196-2 | ASTM C 114 | |
| 317 | Common cements and special cements, cements, cementitious binders E | Sulfide content Range (0,1 - 2,0)% Range (0,02 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Titrimetric method | PN-EN 196-2 | |
| 318 | Common cements and special cements, cements, cementitious binders E | Manganese content Range (0,005 - 2,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN 196-2 | |
| 319 | Common cements and special cements, cements, cementitious binders E | Free water (moisture) and dry substance content Range (0,05 - 99,9)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB/LC-15 | |
| 320 | Common cements and special cements, cements, cementitious binders E | Quantitative content of mineral components (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
CEN TR 196-4 | ||
| 321 | Common cements and special cements, cements, cementitious binders E | Free calcium oxide CaOfree content Range (0,01 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PB/LC-22 | |
| 322 | Common cements and special cements, cements, cementitious binders E | Phosphorus pentoxide P2O5 content Range (0,001 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PB/LC-26 | |
| 323 | Common cements and special cements, cements, cementitious binders E | Titanium oxide TiO2 content Range (0,06 - 2,5)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN ISO 21587-2 | |
| 324 | Common cements and special cements, cements, cementitious binders E | Pozzolanicity Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-5 | |
| 325 | Common cements and special cements, Carbonate raw materials for the production of cement and building lime, Cement constituents, Calcium aluminate cements, Masonry cements, Aluminosilicate materials, Sands, Mineral waste and additives for cement production, Waste code: 10 01 01; 10 01 02; 10 02 01; 10 01 80 E | Content of oxides / elements, Range;, SiO2 (0,01 - 99,0)%, Si (0,005 - 46,0)%, Fe2O3 (0,01 - 81,0)%, Fe (0,007 - 57,0)%, Al2O3 (0,01 - 90,0)%, Al (0,005 - 48,0)%, TiO2 (0,01 - 41,0)%, Ti (0,006 - 24,0)%, CaO (0,01 - 98,0)%, Ca (0,007 - 70,0)%, MgO (0,01 - 78,0)%, Mg (0,006 - 47,0)%, K2O (0,01 - 40,0)%, K (0,008 - 33,0)%, Na2O (0,01 - 58,0)%, Na (0,007 - 43,0)%, Mn2O3 (0,01 - 10,0)%, Mn (0,007 - 7,0)%, Cr2O3 (0,01 - 10,0)%, Cr (0,007 - 7,0)%, P2O5 (0,01 - 40,0)%, P (0,004 - 17,0)%, SO3 (0,01 - 59,0)%, S (0,004 - 24,0)%, ZnO (0,01 - 10,0)%, Zn (0,008 - 8,0)%, SrO (0,01 - 20,0)%, Sr (0,008 - 17,0)%, Cl- (0,001 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: wavelength dispersive X-ray fluorescence spectrometry | ISO 29581-2 | PN-EN ISO 12677 | PN-EN 196-2 | |
| 326 | Common cements and special cements, Carbonate raw materials for the production of cement and building lime, Cement constituents, Calcium aluminate cements, Masonry cements, Aluminosilicate materials, Ashes, Hydraulic binders, Mineral waste and additives for cement production, Masonry units, Solid fuels (also alternative fuels), lime, soils, cement-containing preparations, eluates (materials dissolved in an acid mixture) E | Mercury (Hg) content Range (0,002 - 4,000) ppm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: atomic absorption spectrometry (DMA-direct measurement) | PB/LC-28 | |
| 327 | Common cements and special cements, Carbonate raw materials for the production of cement and building lime, Calcium aluminate cements, Masonry cements, Hydraulic binders, Cement-containing preparations, Clinker, slag E | Content of water-soluble Cr (VI) Range (0,01 - 25,0) ppm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PB/LC-19 | PN-EN 196-10 SFS 5183 | |
| 328 | Carbonate raw materials for the production of cement and building lime E | Loss on ignition content Range (0,05 – 50,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | PN-EN 459-2 | |
| 329 | Carbonate raw materials for the production of cement and building lime E | Content of insoluble matter (NR) Range (0,05 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | PN-EN 459-2 | |
| 330 | Carbonate raw materials for the production of cement and building lime E | Sulphuric anhydride SO3 content Range (0,01 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | PN-EN 459-2 | |
| 331 | Carbonate raw materials for the production of cement and building lime E | Chloride Cl ̅ content Range (0,0005 - 0,50)% Range (0,005 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Potentiometric method; Volhard titrimetric method | PN-EN 196-2 | |
| 332 | Carbonate raw materials for the production of cement and building lime E | Silicon dioxide SiO2 content Range (0,10 - 30,0)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Spectrophotometric method | PB/LC-5 PB/LC-6 | PN-EN 196-2 | |
| 333 | Carbonate raw materials for the production of cement and building lime E | Iron (III) oxide Fe2O3 content Range (0,15 - 5,0)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method; Spectrophotometric method | PN-EN 196-2 | |
| 334 | Carbonate raw materials for the production of cement and building lime E | Aluminium oxide Al2O3 content Range (0,05 - 8,5)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 335 | Carbonate raw materials for the production of cement and building lime E | Calcium oxide CaO content Range (0,01 - 56,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | PN-EN 459-2 | |
| 336 | Carbonate raw materials for the production of cement and building lime E | Magnesium oxide MgO content Range (0,02 - 30,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | PN-EN 459-2 | |
| 337 | Carbonate raw materials for the production of cement and building lime E | Carbon dioxide CO2 content Range (0,05 - 50,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | PN-EN 459-2 | |
| 338 | Carbonate raw materials for the production of cement and building lime E | Carbonate content (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
I/LC-21 | ||
| 339 | Carbonate raw materials for the production of cement and building lime E | Alkali content (Na2O, K2O) Range (0,02 - 5,0)% Range (0,001 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame photometry method; Flame atomic absorption spectrometry FAAS | PB/LC-12 | PN-EN 196-2 | ASTM C 114 | |
| 340 | Carbonate raw materials for the production of cement and building lime E | Sulphide S2- content Range (0,1 - 2,0)% Range (0,02 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Titrimetric method | PN-EN 196-2 | |
| 341 | Carbonate raw materials for the production of cement and building lime E | Manganese content Range (0,005 - 1,5)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN 196-2 | |
| 342 | Carbonate raw materials for the production of cement and building lime E | Free water (moisture) and dry substance content Range (0,05 - 99,9)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB/LC-15 | |
| 343 | Carbonate raw materials for the production of cement and building lime E | Free calcium oxide CaOfree content Range (0,01 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PB/LC-22 | PN-EN 1744-1 | |
| 344 | Carbonate raw materials for the production of cement and building lime E | Phosphorus pentoxide P2O5 content Range (0,001 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PB/LC-26 | |
| 345 | Carbonate raw materials for the production of cement and building lime E | Titanium oxide TiO2 content Range (0,06 - 2,5)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN ISO 21587-2 | |
| 346 | Carbonate raw materials for the production of cement and building lime E | Total organic carbon content TOC Range (0,02 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 13639 p.6 | PN-EN 197-1 | |
| 347 | Cement constituents E | Loss on ignition content Range (0,05 - 50,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 348 | Cement constituents E | Content of insoluble matter (NR) Range (0,05 - 80,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | PN-EN 450-1 | PN-EN 197-1 | |
| 349 | Cement constituents E | Sulphuric anhydride SO3 content Range (0,01 - 59,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 350 | Cement constituents E | Chloride Cl ̅ content Range (0,0005 - 0,50)% Range (0,005 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Potentiometric method; Volhard titrimetric method | PN-EN 196-2 | |
| 351 | Cement constituents E | Silicon dioxide SiO2 content Range (0,10 - 99,9)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Spectrophotometric method | PB/LC-5 PB/LC-6 | PN-EN 196-2 | |
| 352 | Cement constituents E | Iron (III) oxide Fe2O3 content Range (0,15 - 15,0)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method; Spectrophotometric method | PN-EN 196-2 | |
| 353 | Cement constituents E | Aluminium oxide Al2O3 content Range (0,05 - 85,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 354 | Cement constituents E | Calcium oxide CaO content Range (0,01 - 65,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PB/LC-9 | PN-EN 196-2 | PN-EN 197-1 | |
| 355 | Cement constituents E | Magnesium oxide MgO content Range (0,02 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PB/LC-10 | PN-EN 196-2 | |
| 356 | Cement constituents E | Carbon dioxide CO2 content Range (0,05 - 45,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 357 | Cement constituents E | Alkali content (Na2O, K2O) Range (0,02 - 5,0)% Range (0,001 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame photometry method; Flame atomic absorption spectrometry FAAS | PB/LC-12 | PN-EN 196-2 | ASTM C 114 | |
| 358 | Cement constituents E | Sulphide S2- content Range (0,1 - 2,0)% Range (0,02 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Titrimetric method | PN-EN 196-2 | |
| 359 | Cement constituents E | Manganese content Range (0,005 - 2,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN 196-2 | |
| 360 | Cement constituents E | Free water (moisture) and dry substance content Range (0,05 - 99,9)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB/LC-15 | |
| 361 | Cement constituents E | Phosphorus pentoxide P2O5 content Range (0,001 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PB/LC-26 | |
| 362 | Cement constituents E | Titanium oxide TiO2 content Range (0,06 - 2,5)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN ISO 21587-2 | |
| 363 | Cement constituents E | Total organic carbon content TOC Range (0,02 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 13639 p.6 | PN-EN 197-1 | |
| 364 | Limestone E | Silicon dioxide SiO2 content Range (0,10 - 99,9)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Spectrophotometric method | PB/LC-5 PB/LC-6 | PN-EN 196-2 | |
| 365 | Limestone E | Iron (III) oxide Fe2O3 content Range (0,15 - 15,0)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method; Spectrophotometric method | PN-EN 196-2 | |
| 366 | Limestone E | Aluminium oxide Al2O3 content Range (0,05 - 85,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 367 | Limestone E | Calcium oxide CaO content Range (0,01 - 65,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PB/LC-9 | PN-EN 196-2 | PN-EN 197-1 | |
| 368 | Limestone E | Magnesium oxide MgO content Range (0,02 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PB/LC-10 | PN-EN 196-2 | |
| 369 | Limestone E | Carbon dioxide CO2 content Range (0,05 - 45,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | PN-EN 197-1 | |
| 370 | Limestone E | Alkali content (Na2O, K2O) Range (0,02 - 5,0)% Range (0,001 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame photometry method; Flame atomic absorption spectrometry FAAS | PB/LC-12 | PN-EN 196-2 | ASTM C 114 | |
| 371 | Limestone E | Sulphide S2- content Range (0,1 - 2,0)% Range (0,02 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Titrimetric method | PN-EN 196-2 | |
| 372 | Limestone E | Manganese content Range (0,005 - 2,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN 196-2 | |
| 373 | Limestone E | Free water (moisture) and dry substance content Range (0,05 - 99,9)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB/LC-15 | |
| 374 | Limestone E | Phosphorus pentoxide P2O5 content Range (0,001 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PB/LC-26 | |
| 375 | Limestone E | Titanium oxide TiO2 content Range (0,06 - 2,5)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN ISO 21587-2 | |
| 376 | Limestone E | Total organic carbon content TOC Range (0,02 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 13639 p.6 | PN-EN 197-1 | |
| 377 | Limestone E | Fines content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Methylene blue method | PN-EN 933-9 | |
| 378 | Limestone E | Sulphuric anhydride SO3 content Range (0,01 - 1,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 379 | Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E | Loss on ignition content Range (0,05 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 380 | Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E | Content of insoluble matter (NR) Range (0,05 - 80,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 381 | Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E | Sulphuric anhydride SO3 content Range (0,01 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 382 | Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E | Chloride Cl ̅ content Range (0,0005 - 0,50)% Range (0,005 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Potentiometric method; Volhard titrimetric method | PN-EN 196-2 | |
| 383 | Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E | Silicon dioxide SiO2 content Range (0,10 - 99,9)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Spectrophotometric method | PB/LC-5 PB/LC-6 | PN-EN 196-2 | |
| 384 | Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E | Iron (III) oxide Fe2O3 content Range (0,15 - 85,0)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method; Spectrophotometric method | PN-EN 196-2 | |
| 385 | Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E | Aluminium oxide Al2O3 content Range (0,05 - 85,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 386 | Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E | Calcium oxide CaO content Range (0,01 - 65,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 387 | Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E | Magnesium oxide MgO content Range (0,02 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 388 | Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E | Carbon dioxide CO2 content Range (0,05 - 50,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 389 | Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E | Alkali content (Na2O, K2O) Range (0,02 - 5,0)% Range (0,001 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame photometry method; Flame atomic absorption spectrometry FAAS | PB/LC-12 | PN-EN 196-2 | ASTM C 114 | |
| 390 | Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E | Sulphide S2- content Range (0,1 - 2,0)% Range (0,02 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Titrimetric method | PN-EN 196-2 | |
| 391 | Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E | Manganese content Range (0,005 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN 196-2 | |
| 392 | Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E | Free water (moisture) and dry substance content Range (0,05 - 99,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB/LC-15 | |
| 393 | Calcium aluminate cements, Masonry cements, Mineral waste and additions for cement production, Hydraulic binders E | Titanium oxide TiO2 content Range (0,001 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN ISO 21587-1 | PN-EN ISO 21587-2 | |
| 394 | Masonry cements, Hydraulic binders E | Quantitative content of mineral components (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
CEN TR 196-4 | ||
| 395 | Masonry cements, Hydraulic binders E | Free calcium oxide CaOfree content Range (0,01 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PB/LC-22 | |
| 396 | Masonry cements, Hydraulic binders, Mineral waste and additives for cement production E | Phosphorus pentoxide P2O5 content Range (0,001 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PB/LC-26 | |
| 397 | Building lime E | Loss on ignition content Range (0,05 - 30,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 459-2 | |
| 398 | Building lime E | Sulphuric anhydride SO3 content Range (0,01 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 459-2 | |
| 399 | Building lime E | Silicon dioxide SiO2 content Range (0,10 - 5,0)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Spectrophotometric method | PB/LC-5 | PN-EN 196-2 | |
| 400 | Building lime E | Calcium oxide CaO content Range (0,5 - 99,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 459-2 | |
| 401 | Building lime E | Magnesium oxide MgO content Range (0,25 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 459-2 | |
| 402 | Building lime E | Carbon dioxide CO2 content Range (0,10 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 459-2 | |
| 403 | Building lime E | Alkali content (Na2O, K2O) Range (0,02 - 5,0)% Range (0,001 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame photometry method; Flame atomic absorption spectrometry FAAS | PB/LC-12 | PN-EN 196-2 | ASTM C 114 | |
| 404 | Building lime E | Manganese content Range (0,005 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN 196-2 | |
| 405 | Building lime E | Free water (moisture) and dry substance content Range (0,05 - 99,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB/LC-15 | PN-EN 459-2 | |
| 406 | Building lime E | Active lime content Range (0,01 - 99,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 459-2 | |
| 407 | Aluminosilicate materials E | Loss on ignition content Range (0,05 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 408 | Aluminosilicate materials E | Sulphuric anhydride SO3 content Range (0,01 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 409 | Aluminosilicate materials E | Chloride Cl ̅ content Range (0,0005 - 0,50)% Range (0,005 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Potentiometric method; Volhard titrimetric method | PN-EN 196-2 | |
| 410 | Aluminosilicate materials E | Silicon dioxide SiO2 content Range (0,10 - 99,9)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Spectrophotometric method | PB/LC-6 | PN-EN 196-2 | |
| 411 | Aluminosilicate materials E | Iron (III) oxide Fe2O3 content Range (0,15 - 20,0)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method; Spectrophotometric method | PN-EN 196-2 | |
| 412 | Aluminosilicate materials E | Aluminium oxide Al2O3 content Range (0,05 - 85,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 413 | Aluminosilicate materials E | Calcium oxide CaO content Range (0,01 - 30,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 414 | Aluminosilicate materials E | Magnesium oxide MgO content Range (0,02 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 415 | Aluminosilicate materials E | Alkali content (Na2O, K2O) Range (0,02 - 5,0)% Range (0,001 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame photometry method; Flame atomic absorption spectrometry FAAS | PB/LC-12 | PN-EN 196-2 | ASTM C 114 | |
| 416 | Aluminosilicate materials E | Sulphide S2- content Range (0,1 - 2,0)% Range (0,02 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Titrimetric method | PN-EN 196-2 | |
| 417 | Aluminosilicate materials E | Manganese content Range (0,005 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN 196-2 | |
| 418 | Aluminosilicate materials E | Free water (moisture) and dry substance content Range (0,05 - 99,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB/LC-15 | |
| 419 | Aluminosilicate materials E | Phosphorus pentoxide P2O5 content Range (0,001 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PB/LC-26 | |
| 420 | Aluminosilicate materials E | Titanium oxide TiO2 content Range (0,06 - 2,5)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN ISO 21587-2 | |
| 421 | Building lime, Ashes, Slags, Silica fume, Hydraulic binders, Aggregates, Mortars, plasters, building compounds and other materials, Masonry units, Gypsum products E | Content of oxides / elements SiO2 (0,01 - 99,0)% Si (0,005 - 46,0)% Fe2O3 (0,01 - 81,0)% Fe (0,007 - 57,0)% Al2O3 (0,01 - 90,0)% Al (0,005 - 48,0)% TiO2 (0,01 - 41,0)% Ti (0,006 - 24,0)% CaO (0,01 - 98,0)% Ca (0,007 - 70,0)% MgO (0,01 - 78,0)% Mg (0,006 - 47,0)% K2O (0,01 - 40,0)% K (0,008 - 33,0)% Na2O (0,01 - 58,0)% Na (0,007 - 43,0)% Mn2O3 (0,01 - 10,0)% Mn (0,007 - 7,0)% Cr2O3 (0,01 - 10,0)% Cr (0,007 - 7,0)% P2O5 (0,01 - 40,0)% P (0,004 - 17,0)% SO3 (0,01 - 59,0)% S (0,004 - 24,0)% ZnO (0,01 - 10,0)% Zn (0,008 - 8,0)% SrO (0,01 - 20,0)% Sr (0,008 - 17,0)% Cl (0,001 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Wavelength-dispersive X-ray fluorescence spectrometry | ISO 29581-2 | PN-EN 196-2 | |
| 422 | Ashes E | Loss on ignition content Range (0,05 - 40,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 450-1 | PN-EN 196-2 | |
| 423 | Ashes E | Content of insoluble matter (NR) Range (0,05 - 80,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | PN-EN 197-1 | |
| 424 | Ashes E | Sulphuric anhydride SO3 content Range (0,01 - 15,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | PN-EN 197-1 | |
| 425 | Ashes E | Chloride Cl ̅ content Range (0,0005 - 0,50)% Range (0,005 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Potentiometric method; Volhard titrimetric method | PN-EN 196-2 | |
| 426 | Ashes E | Silicon dioxide SiO2 content Range (0,10 - 80,0)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Spectrophotometric method | PB/LC-6 | PN-EN 450-1 | PN-EN 196-2 | PN-EN 197-1 | |
| 427 | Ashes E | Iron (III) oxide Fe2O3 content Range (0,15 - 25,0)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method; Spectrophotometric method | PN-EN 196-2 | |
| 428 | Ashes E | Aluminium oxide Al2O3 content Range (0,05 - 30,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 429 | Ashes E | Calcium oxide CaO content Range (0,01 - 25,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | PN-EN 197-1 | |
| 430 | Ashes E | Magnesium oxide MgO content Range (0,02 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 431 | Ashes E | Carbon dioxide CO2 content Range (0,05 - 50,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | PN-EN 197-1 | |
| 432 | Ashes E | Alkali content (Na2O, K2O) Range (0,02 - 5,0)% Range (0,001 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame photometry method; Flame atomic absorption spectrometry FAAS | PB/LC-12 | PN-EN 196-2 | PN-G-04528-10 | ASTM C 114 | |
| 433 | Ashes E | Manganese content Range (0,005 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN 196-2 | |
| 434 | Ashes E | Phosphorus pentoxide P2O5 content Range (0,001 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN 450-1 Załącznik C | |
| 435 | Ashes E | Titanium oxide TiO2 content Range (0,06 - 2,5)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN ISO 21587-2 | |
| 436 | Ashes E | Free water (moisture) and dry substance content Range (0,05 - 99,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB/LC-15 | |
| 437 | Ashes E | Free calcium oxide CaOfree content Range (0,01 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PB/LC-22 | PN-EN 451-1 | |
| 438 | Ashes E | SiO2react, Calculated Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 197-1 | PN-EN 196-2 | ||
| 439 | Ashes E | CaO2reakt, Calculated Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 197-1 | ||
| 440 | Slags, silica fume E | Loss on ignition content Range (0,05 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 441 | Slags, silica fume E | Sulphuric anhydride SO3 content Range (0,01 - 15,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 442 | Slags, silica fume E | Chloride Cl ̅ content Range (0,0005 - 0,50)% Range (0,005 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Potentiometric method; Volhard titrimetric method | PN-EN 196-2 | |
| 443 | Slags, silica fume E | Silicon dioxide SiO2 content Range (0,10 - 99,9)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Spectrophotometric method | PB/LC-5 PB/LC-6 | PN-EN 196-2 | |
| 444 | Slags, silica fume E | Iron (III) oxide Fe2O3 content Range (0,15 - 30,0)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method; Spectrophotometric method | PN-EN 196-2 | |
| 445 | Slags, silica fume E | Aluminium oxide Al2O3 content Range (0,05 - 30,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 446 | Slags, silica fume E | Calcium oxide CaO content Range (0,01 - 50,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 447 | Slags, silica fume E | Magnesium oxide MgO content Range (0,02 - 15,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 448 | Slags, silica fume E | Alkali content (Na2O, K2O) Range (0,02 - 5,0)% Range (0,001 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame photometry method; Flame atomic absorption spectrometry FAAS | PB/LC-12 | PN-EN 196-2 | ASTM C 114 | |
| 449 | Slags E | Sulphide S2- content Range (0,1 - 2,0)% Range (0,02 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Titrimetric method | PN-EN 196-2 | |
| 450 | Slags E | Manganese content Range (0,005 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN 196-2 | |
| 451 | Slags E | Moisture content Range (0,05 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 15167-1 Załącznik A | |
| 452 | Silica fume E | Free calcium oxide CaOfree content Range (0,01 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 451-1 | |
| 453 | Silica fume E | Titanium oxide TiO2 content Range (0,001 - 3,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN ISO 21587-1 | PN-EN ISO 21587-2 | |
| 454 | Silica fume E | Free water (moisture) and dry substance content Range (0,05 - 25,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB/LC-15 | PN-EN 13263-1 | |
| 455 | Rapid hardening hydraulic road binders E | Sulphuric anhydride SO3 content Range (0,01 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 13282-1 | PN-EN 196-2 | |
| 456 | Normal hardening hydraulic road binders E | Sulphuric anhydride SO3 content Range (0,01 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 13282-2 | PN-EN 196-2 | |
| 457 | Products for external thermal insulation systems E | Loss on ignition content Range (0,05 - 99, 5)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | ZUAT-15/V.03/2003 ZUAT-15/V.04/2003 | |
| 458 | Products for external thermal insulation systems E | Dry matter content Range (0,05 - 99, 5)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | ZUAT-15/V.03/2003 ZUAT-15/V.04/2003 ETAG 004 Europejskie Dokumenty Oceny | |
| 459 | Products for external thermal insulation systems E | Ash content Range (0,05 - 99, 5)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | ETAG 004 Europejskie Dokumenty Oceny | |
| 460 | Reinforcing meshes/fabrics for thermal insulation systems E | Organic matter content (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Europejskie Dokumenty Oceny | ||
| 461 | Aggregates E | Presence of humus Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Visual method | PN-EN 1744-1 | |
| 462 | Aggregates E | Fines content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Methylene blue method | PN-EN 933-9 | |
| 463 | Aggregates E | Loss on ignition content Range (0,05 - 45,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | PN-EN 1744-1 | |
| 464 | Aggregates E | Content of sulphates soluble in HCl acid Range (0,01 - 59,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | PN-EN 1744-1 | |
| 465 | Aggregates E | Chloride Cl ̅ content Range (0,0005 - 0,50)% Range (0,005 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Potentiometric method; Volhard titrimetric method | PN-EN 196-2 | PN-EN 1744-1 | |
| 466 | Aggregates E | Total sulfur content Range (0,1 - 2,0)% Range (0,02 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Titrimetric method | PN-EN 196-2 | PN-EN 1744-1 | |
| 467 | Aggregates E | Free calcium oxide CaOfree content Range (0,01 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PB/LC-22 | PN-EN 1744-1 | |
| 468 | Aggregates E | Alkali content (Na2O, K2O) Range (0,02 - 5,0)% Range (0,001 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame photometry method; Flame atomic absorption spectrometry FAAS | PB/LC-12 | PN-EN 196-2 | ASTM C 114 | |
| 469 | Sands E | Loss on ignition content Range (0,05 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 470 | Sands E | Sulphuric anhydride SO3 content Range (0,01 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 471 | Sands E | Silicon dioxide SiO2 content Range (0,10 - 99,9)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Spectrophotometric method | PB/LC-6 | PN-EN 196-2 | |
| 472 | Sands E | Iron (III) oxide Fe2O3 content Range (0,15 - 20,0)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method; Spectrophotometric method | PN-EN 196-2 | |
| 473 | Sands E | Aluminium oxide Al2O3 content Range (0,05 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 474 | Sands E | Calcium oxide CaO content Range (0,01 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PB/LC-9 | PN-EN 196-2 | |
| 475 | Sands E | Magnesium oxide MgO content Range (0,02 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PB/LC-10 | PN-EN 196-2 | |
| 476 | Sands E | Carbon dioxide CO2 content Range (0,05 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 477 | Sands E | Alkali content (Na2O, K2O) Range (0,02 - 5,0)% Range (0,001 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame photometry method; Flame atomic absorption spectrometry FAAS | PB/LC-12 | PN-EN 196-2 | ASTM C 114 | |
| 478 | CEN standard sand E | Moisture content Range (0,05 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB/LC-17 | |
| 479 | Admixtures for concrete, mortar and grout E | Chloride Cl ̅ content Range (0,0005 - 0,50)% Range (0,005 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Potentiometric method; Volhard titrimetric method | PN-EN 480-10 | |
| 480 | Admixtures for concrete, mortar and grout E | Alkali content (Na2O, K2O) Range (0,02 - 5,0)% Range (0,01 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame photometry method; Flame atomic absorption spectrometry FAAS | PB/LC-12 | PN-EN 480-12 | |
| 481 | Admixtures for concrete, mortar and grout E | Free water (moisture) and dry substance content Range (0,05 - 99,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB/LC-15 | PN-EN 480-8 | |
| 482 | Admixtures for concrete, mortar and grout E | pH Range 0,5 - 13,0 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Potentiometric method | PB/LC-27 | ISO 4316 | |
| 483 | Gypsum binders and plasters E | Sulphuric anhydride SO3 content Range (0,01 - 59,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 13279-2 | |
| 484 | Mortars and building compounds E | Chloride Cl ̅ content Range (0,005 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Volhard titrimetric method | PN-EN 1015-17 | |
| 485 | Masonry units E | Loss on ignition content Range (0,05 - 30,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 486 | Masonry units E | Sulphuric anhydride SO3 content Range (0,01 - 40,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 487 | Masonry units E | Chloride Cl ̅ content Range (0,0005 - 0,50)% Range (0,005 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Potentiometric method; Volhard titrimetric method | PN-EN 196-2 | |
| 488 | Masonry units E | Silicon dioxide SiO2 content Range (0,10 - 80,0)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Spectrophotometric method | PB/LC-5 PB/LC-6 | PN-EN 196-2 | |
| 489 | Masonry units E | Iron (III) oxide Fe2O3 content Range (0,15 - 5,0)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method; Spectrophotometric method | PN-EN 196-2 | |
| 490 | Masonry units E | Aluminium oxide Al2O3 content Range (0,05 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 491 | Masonry units E | Calcium oxide CaO content Range (0,01 - 60,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 492 | Masonry units E | Magnesium oxide MgO content Range (0,02 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PB/LC-10 | PN-EN 772-5 | |
| 493 | Masonry units E | Carbon dioxide CO2 content Range (0,05 - 50,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 494 | Masonry units E | Alkali content (Na2O, K2O) Range (0,02 - 5,0)% Range (0,001 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame photometry method; Flame atomic absorption spectrometry FAAS | PB/LC-12 | PN-EN 772-5 | PN-EN 196-2 | ASTM C 114 | |
| 495 | Masonry units E | Sulphide S2- content Range (0,1 - 2,0)% Range (0,02 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method; Titrimetric method | PN-EN 196-2 | |
| 496 | Masonry units E | Manganese content Range (0,005 - 1,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN 196-2 | |
| 497 | Masonry units E | Free water (moisture) and dry substance content Range (0,05 - 99,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB/LC-15 | |
| 498 | Solutions of all construction products E | pH Range 0,5 - 13,0 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited |
Potentiometric method | PB/LC-27 | |
| 499 | Pigments and extenders E | pH Range 0,5 - 13,0 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited |
Potentiometric method | PN-EN ISO 787-9 | |
| 500 | Products containing surfactants E | pH Range 0,5 - 13,0 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited |
Potentiometric method | ISO 4316 | |
| 501 | Floor screeds and screed materials E | pH Range 0,5 - 13,0 Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited |
Potentiometric method | PN-EN 13454-2 | |
| 502 | Gypsums E | Loss on ignition content Range (0,05 - 40,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited |
Gravimetric method | PN-EN 196-2 | |
| 503 | Gypsums E | Sulphuric anhydride SO3 content Range (0,01 - 59,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited |
Gravimetric method | PN-EN 196-2 VGB-M 701 e | |
| 504 | Gypsums E | Chloride Cl ̅ content Range (0,0005 - 0,50)% Range (0,005 - 10,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited |
Potentiometric method; Volhard titrimetric method | PN-EN 196-2 VGB-M 701 e | |
| 505 | Gypsums E | Silicon dioxide SiO2 content Range (0,10 - 10,0)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited |
Gravimetric method; Spectrophotometric method | PB/LC-5 | PN-EN 196-2 VGB-M 701 e | |
| 506 | Gypsums E | Iron (III) oxide Fe2O3 content Range (0,15 - 2,0)% Range (0,005 - 0,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited |
Titrimetric method; Spectrophotometric method | PN-EN 196-2 VGB-M 701 e | |
| 507 | Gypsums E | Aluminium oxide Al2O3 content Range (0,05 - 2,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited |
Titrimetric method | PN-EN 196-2 VGB-M 701 e | |
| 508 | Gypsums E | Calcium oxide CaO content Range (0,01 - 40,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited |
Titrimetric method | PN-EN 196-2 VGB-M 701 e | |
| 509 | Gypsums E | Magnesium oxide MgO content Range (0,02 - 6,5)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 VGB-M 701 e | |
| 510 | Gypsums E | Alkali content (Na2O, K2O) Range (0,02 - 5,0)% Range (0,001 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame photometry method; Flame atomic absorption spectrometry FAAS | PB/LC-12 | PN-EN 196-2 VGB-M 701 e | ASTM C 114 | |
| 511 | Gypsums E | Free water (moisture) and dry substance content Range (0,05 - 99,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB/LC-15 VGB-M 701 e | |
| 512 | Glass E | Resistance to water Range szkła o niższej odporności Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-ISO 719 | |
| 513 | Glass, kaolins and clays, magnesites and dolomites, zircon raw materials, other aluminosilicate materials E | Content of oxides / elements, Range, SiO2 (0,01 - 99,0)%, Si (0,005 - 46,0)%, Fe2O3 (0,01 - 81,0)%, Fe (0,007 - 57,0)%, Al2O3 (0,01 - 90,0)%, Al (0,005 - 48,0)%, TiO2 (0,01 - 41,0)%, Ti (0,006 - 24,0)%, CaO (0,01 - 98,0)%, Ca (0,007 - 70,0)%, MgO (0,01 - 78,0)%, Mg (0,006 - 47,0)%, K2O (0,01 - 40,0)%, K (0,008 - 33,0)%, Na2O (0,01 - 58,0)%, Na (0,007 - 43,0)%, Cr2O3 (0,01 - 10,0)%, Cr (0,007 - 7,0)%, P2O5 (0,01 - 40,0)%, P (0,004 - 17,0)%, SO3 (0,01 - 59,0)%, S (0,004 - 24,0)%, ZnO (0,01 - 10,0)%, Zn (0,008 - 8,0)%, SrO (0,01 - 20,0)%, Sr (0,008 - 17,0)%, BaO (0,01 - 43,0)%, Ba (0,009 - 38,0)%, HfO2 (0,01 - 9,0)%, Hf (0,008 - 12,0)%, NiO (0,01 - 12,0)%, Ni (0,008 - 10,0)%, ZrO2 (0,01 - 65,0)%, Zr (0,007 - 48,0)%, CuO (0,01 - 8,0)%, Cu (0,008 - 7,0)%, PbO (0,01 - 10,0)%, Pb (0,009 - 9,0)%, V2O5 (0,01 - 10,0)%, V (0,006 - 5,6)%, Mn3O4 (0,01 - 80,0)%, Mn (0,007 - 58,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Wavelength-dispersive X-ray fluorescence spectrometry | ISO 29581-2 | PN-EN ISO 12677 | |
| Centre for Sustainable Construction; Concrete and Lightweight Composites Research Group | |||||
| 514 | Masonry mortars | Frost resistance | PN-B-04500:1985 | ||
| 515 | Concrete | Water permeability of concrete | Method: pressure | PN-B-06250:1988 | |
| 516 | Concrete | Resistance to freezing | Method: measurement of strength reduction and mass loss | PN-B-06250:1988 p. 6.5 | |
| 517 | Masonry mortars E | Sieve analysis Range (0,063 - 8,0) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 1015-1 | |
| 518 | Masonry mortars E | Consistence of fresh mortar Range (100 - 300) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: flow table | PN-EN 1015-3 | |
| 519 | Masonry mortars E | Consistence of fresh mortar Penetration range (0 - 70) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a penetrometer | PN-EN 1015-4 | |
| 520 | Masonry mortars E | Bulk density of fresh mortar Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 1015-6 | |
| 521 | Masonry mortars E | Air content in fresh mortar Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: A – pressure; Method: B – alcohol | PN-EN 1015-7 | |
| 522 | Masonry mortars E | Workable life of fresh mortar Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: penetrating rod | PN-EN 1015-9 | |
| 523 | Masonry mortars E | Workable life of fresh mortar Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: flow table | PN-EN 1015-9 | |
| 524 | Masonry mortars E | Correction time of fresh mortar Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: direct measurement | PN-EN 1015-9 | |
| 525 | Masonry mortars E | Density of dried hardened mortar Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 1015-10 | |
| 526 | Masonry mortars E | Flexural strength Force range (0,05 - 6,0) kN Compressive strength Force range (1,0 - 100,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: constant rate of force increase | PN-EN 1015-11 | |
| 527 | Masonry mortars E | Adhesion to the substrate Force range (0,1 - 15,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: Pull-off | PN-EN 1015-12 | |
| 528 | Masonry mortars E | Coefficient of water absorption due to capillary action of hardened mortar Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 1015-18 | |
| 529 | Masonry mortars E | Water vapour transmission coefficient of hardened rendering and plastering mortars Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 1015-19 | |
| 530 | Masonry mortars E | Suitability of one-coat rendering mortars for substrates Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 1015-21 | ||
| 531 | Masonry mortars + masonry units E | Flexural tensile strength by the torsion method in the plane perpendicular to the plane of the wall and with failure by a crack in the bed joint for the masonry unit Range (0,1 - 10) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: constant rate of force increase | PN-EN 1052-5 | |
| 532 | Thermal insulation materials E | Thermal conductivity Range (0,001 - 0,500) W/(m×K) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Plate apparatus method with a heat flow density sensor | PN-EN 12667 „N” | PN-ISO 8301 „N” | PN-EN 12664 „N” | PN-EN 12939 „N” | |
| 533 | Products and systems for the protection and repair of concrete structures E | Compressive strength Force range (3,0 - 250,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: constant rate of force increase | PN-EN 12190 | |
| 534 | Products and systems for the protection and repair of concrete structures E | Adhesion Force range (0,5 - 25,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: pull-off | PN-EN 1542 | |
| 535 | Products and systems for the protection and repair of concrete structures E | Capillary absorption Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: gravimetric | PN-EN 13057 | |
| 536 | Products and systems for the protection and repair of concrete structures E | Thermal compatibility Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: thermal cycles – reference method | PN-EN 13687-1 | |
| 537 | Materials for floor screeds E | Flexural strength Force range (0,05 - 6,0) kN Compressive strength Force range (1,0 - 200,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: constant rate of force increase | PN-EN 13892-2 | |
| 538 | Materials for floor screeds E | Abrasion resistance Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: Böhme – mass loss | PN-EN 13892-3 | |
| 539 | Materials for floor screeds E | Adhesion Force range (0,1 - 15,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: Pull-off | PN-EN 13892-8 | |
| 540 | Materials for floor screeds E | Open time Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: flow | PN-EN 13454-2 | |
| 541 | Materials for floor screeds E | Shrinkage and swelling Kaufmann Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: Grauff-type apparatus | PN-EN 13454-2 | |
| 542 | Materials for floor screeds E | Flowability Range (30 - 300) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: flow | PN-EN 12706 | |
| 543 | Materials for floor screeds E | Dimensional changes of floor smoothing compounds Kaufmann Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: Grauff-type apparatus | PN-EN 13872 | |
| 544 | Materials for floor screeds E | Consistency of fluid mortars Range (100 - 300) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: flow | PN-EN 13454-2 | |
| 545 | Materials for floor screeds E | Consistency of stiff-plastic mortars Range (100 - 300) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: flow table | PN-EN 13454-2 | |
| 546 | Admixtures for masonry mortar and concrete E | Conventional dry matter content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 480-8 | |
| 547 | Admixtures for masonry mortars E | Consistence of fresh mortar Penetration range (0 - 70) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a penetrometer | PN-EN 1015-4 | |
| 548 | Admixtures for masonry mortars E | Amount of water required to obtain a standard consistence Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 480-13 | ||
| 549 | Admixtures for masonry mortars E | Air content in fresh mortar Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: A – pressure; Method: B – alcohol | PN-EN 1015-7 | |
| 550 | Admixtures for masonry mortars E | Workable life of fresh mortar Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: penetrating rod | PN-EN 1015-9 | |
| 551 | Admixtures for masonry mortars E | Flexural strength Force range (0,05 - 6,0) kN Compressive strength Force range (1,0 - 100,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: constant rate of force increase | PN-EN 1015-11 | |
| 552 | Admixtures for concrete E | Setting time Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: Vicat apparatus | PN-EN 480-2 | |
| 553 | Admixtures for concrete E | Capillary absorption Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: gravimetric | PN-EN 480-5 | |
| 554 | Admixtures for concrete E | Consistency Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: slump | PN-EN 12350-2 | |
| 555 | Admixtures for concrete E | Consistency Range (200 - 700) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: flow table | PN-EN 12350-5 | |
| 556 | Admixtures for concrete E | Compressive strength Force range (22,5 - 3000) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: constant rate of force increase | PN-EN 12390-3 | |
| 557 | Admixtures for concrete E | Air content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: pressure | PN-EN 12350-7 | |
| 558 | Fresh concrete E | Consistency Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: slump | PN-EN 12350-2 | |
| 559 | Fresh concrete E | Air content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: pressure | PN-EN 12350-7 | |
| 560 | Concrete E | Compressive strength Force range (22,5 - 3000) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: constant rate of force increase | PN-EN 12390-3 | |
| 561 | Concrete E | Depth of penetration of water under pressure Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 12390-8 | ||
| 562 | Concrete E | Density Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: gravimetric | PN-EN 12390-7 | |
| 563 | Concrete E | Resistance to freezing Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: measurement of strength reduction and mass loss | PN-B-06265 Załącznik N | |
| 564 | Concrete E | Sampling Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 12350-1 | ||
| 565 | Flexible waterproofing products, bitumen, plastic and rubber products E | Watertightness Range (0 - 100) kPa Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 1928 „N” | ||
| 566 | Thick-layer polymer-modified bituminous coatings E | Watertightness Range (0 - 100) kPa Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PN-EN 15820 „N” | ||
| 567 | Water-impermeable products E | Watertightness Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: gravimetric | PN-EN 14891 „N” | |
| 568 | Renders based on organic binders E | Water vapour transmission coefficient for free films Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: gravimetric | PN-EN ISO 7783 | |
| 569 | Renders based on organic binders E | Water permeability Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: gravimetric | PN-EN 1062-3 | |
| 570 | Renders based on organic binders E | Adhesion Force range (0,1 - 15,0) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: Pull-off | PN-EN 1542 | |
| 571 | Renders based on organic binders E | Thermal compatibility Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Method: thermal cycles-reference method | PN-EN 13687-3 | |
| 572 | Calcium aluminate cement E | Setting time Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: Vicat apparatus | PN-EN 480-2 | |
| 573 | Aggregates E | Grain composition, Fraction (0,063 - 80) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 933-1 | |
| 574 | Aggregates E | Particle shape – flakiness index, Fraction (4 - 80) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 933-3 | |
| 575 | Aggregates E | Particle shape – shape index Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 933-4 | |
| 576 | Aggregates E | Percentage of crushed and broken surfaces in coarse aggregate particles, Fraction (4 - 63) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: macroscopic | PN-EN 933-5 | |
| 577 | Aggregates E | Sand equivalent value Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 933-8 | ||
| 578 | Aggregates E | Resistance to fragmentation, Fraction (4 - 16) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric Los Angeles | PN-EN 1097-2 | |
| 579 | Aggregates E | Bulk density and voids, Fraction (0 - 63) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 1097-3 | ||
| 580 | Aggregates E | Water content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 1097-5 | |
| 581 | Aggregates E | Particle density and water absorption, Fraction (4 - 31,5) mm; (0,063 - 4) mm (0,063 - 31,5) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 1097-6 p.8, 9 | |
| 582 | Aggregates E | Testing of the influence of recycled aggregate extract on the initial setting time Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 1744-6 | ||
| 583 | Aggregates E | Frost resistance, Fraction (4 - 63) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 1367-6 | PN-EN 1367-1 | ||
| 584 | Aggregates E | Drying shrinkage Fraction (0 - 20) mm Kaufmann Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: Grauff-type apparatus | PN-EN 1367-4 | |
| 585 | Aggregates E | Content of light impurities, Fraction (0 - 63) mm Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 1744-1 p. 14.2 | |
| 586 | Aggregates E | Abrasion resistance Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Micro-Deval method | PN-EN 1097-1 | |
| 587 | Aggregates E | Alkali reactivity Grauff Kaufmana Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Long-term method – measurement of length changes of beams – apparatus type | ASTM C 1293 | |
| 588 | Aggregates E | Alkali reactivity Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: accelerated beam test on mortar | Procedura badawcza GDDKiA PB/1/18 | |
| 589 | Aggregates E | Alkali reactivity Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: long-term beam test on concrete | Procedura badawcza GDDKiA PB/2/18 | |
| 590 | Aggregates E | Polishability Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PSV method | PN-EN 1097-8 | |
| 591 | Aggregates E | Simplified petrographic description Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 932-3 | ||
| 592 | Aggregates E | Sampling Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 932-1 p. 8.2, p.8.8, p.8.9 | ||
| 593 | Concrete paving flags E | Freeze/thaw resistance with de-icing salt Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 1339 Załącznik D | ||
| 594 | Concrete paving flags E | Bending strength and breaking load Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 1339 Załącznik F | ||
| 595 | Concrete paving flags E | Slip / skid resistance Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 1339 Załącznik I | ||
| 596 | Concrete paving blocks E | Freeze/thaw resistance with de-icing salt Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 1338 Załącznik D | ||
| 597 | Concrete paving blocks E | Splitting tensile strength Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 1338 Załącznik F | ||
| 598 | Concrete paving blocks E | Slip/slipping resistance Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 1338 Załącznik I | ||
| 599 | Concrete kerb units E | Resistance to de-icing salts Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: gravimetric | PN-EN 1340 Załącznik D | |
| 600 | Concrete kerb units E | Flexural strength Range (5 – 150) kN Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: constant rate of force increase | PN-EN 1340 Załącznik F | |
| 601 | Concrete kerb units E | Slip/slipping resistance Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 1340 Załącznik I | ||
| Centre for Sustainable Construction; Cement Research Group | |||||
| 602 | Solid fuels, Hard coal | Volatile matter content Range (10 - 65,0)% |
Gravimetric method | PN-ISO 562:2000 | |
| 603 | Industrial waste, mineral raw materials and building materials, slurries and sewage sludge | Total carbon content Range (0,01 - 95,0)% |
High-temperature combustion with IR detection | PN-EN 13137:2004 | |
| 604 | Industrial waste, mineral raw materials and building materials, slurries and sewage sludge | Total organic carbon (TOC) content Range (0,01 - 95,0)% |
High-temperature combustion with IR detection | PN-EN 13137:2004 | |
| 605 | Industrial waste, mineral raw materials and building materials, slurries and sewage sludge | Total inorganic carbon content (TIC) (calculated) | PN-EN 13137:2004 | ||
| 606 | Coal-associated shales and silts | Total carbon content Range (0,01 - 95,0)% |
High-temperature combustion with IR detection | PN-EN 13137:2004 | |
| 607 | Coal-associated shales and silts | Total organic carbon (TOC) content Range (0,01 - 95,0)% |
High-temperature combustion with IR detection | PN-EN 13137:2004 | |
| 608 | Coal-associated shales and silts | Total inorganic carbon content (TIC) Range (0,01 - 35,0)% |
High-temperature combustion with IR detection | PN-EN 13137:2004 | |
| 609 | Solid fuels: E, Hard coal | Total carbon content (TC) Range (20,0 - 99,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with IR detection | PN-G-04571 | |
| 610 | Solid fuels: E, Hard coal | Gross calorific value Range (25000 - 32000) kJ/kg Net calorific value (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Calorimetric method | PN-ISO 1928 | |
| 611 | Solid fuels: E, Hard coal | Ash content Range (1,0 - 50,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-ISO 1171 | |
| 612 | Solid fuels: E, Hard coal | Volatile matter content Range (10 - 65,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-G-04516 | |
| 613 | Solid fuels: E, Hard coal | Chlorine content Range (0,050 - 1,50)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Potentiometric titration method | PN-ISO 587 p. 7.2.3. | |
| 614 | Solid fuels: E, Hard coal | Total moisture content Range (1,0 - 50,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-ISO 589 Metoda B1 i B2 | |
| 615 | Solid fuels: E, Hard coal | First-stage (free) moisture content Range (1,0 - 50,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-ISO 589 | |
| 616 | Solid fuels: E, Hard coal | Moisture content in the analytical sample Range (0,5 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-ISO 11722 | |
| 617 | Solid fuels: E, Hard coal | Second-stage moisture content (moisture remaining in the sample) Range (0,1 - 20,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN- ISO 589 Metoda A1 i A2 | |
| 618 | Solid fuels: E, Hard coal | Total moisture content (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN- ISO 589 Metoda A1 i A2 | ||
| 619 | Solid fuels: E, Hard coal | Total sulfur content Range (0,20 - 5,00)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with IR detection | PN-G-04584 | |
| 620 | Carbonate raw materials E | Total organic carbon (TOC) content Range (0,01 - 35,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with IR detection | PN-EN 13639 | |
| 621 | Industrial waste, mineral raw materials and construction materials, slurries and sewage sludge E | Total carbon content Range (0,01 - 95,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with IR detection | PN-ISO 10694 | |
| 622 | Industrial waste, mineral raw materials and construction materials, slurries and sewage sludge E | Total organic carbon (TOC) content Range (0,01 - 95,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with IR detection | PN-ISO 10694 | |
| 623 | Industrial waste, mineral raw materials and construction materials, slurries and sewage sludge E | Total moisture content Range (1,0 - 90,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB-4/BC | |
| 624 | Industrial waste, mineral raw materials and construction materials, slurries and sewage sludge E | Analytical moisture content Range (0,1 - 50,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB-4/BC | |
| 625 | Industrial waste, mineral raw materials and construction materials, slurries and sewage sludge E | Moisture content in the air-dried sample Range (1,0 - 50,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB-4/BC | |
| 626 | Industrial waste, mineral raw materials and construction materials, slurries and sewage sludge E | Transient moisture content Range (1,0 - 70,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PB-4/BC | |
| 627 | Industrial waste, mineral raw materials and construction materials, slurries and sewage sludge E | Total moisture content (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PB-4/BC | ||
| 628 | Industrial waste, mineral raw materials and construction materials, slurries and sewage sludge E | Total sulfur content Range (0,01 - 13,00)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with IR detection | PB-2/BC | |
| 629 | Industrial waste, mineral raw materials and building materials, sludges E | Gross calorific value Range (1000 - 20000) kJ/kg Net calorific value (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Calorimetric method | PB-3/BC | |
| 630 | Sewage sludge E | Gross calorific value Range (1000 - 20000) kJ/kg Net calorific value (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Calorimetric method | PN-EN 15170 | |
| 631 | Aggregates E | Alkali reactivity Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Accelerated method using the Graff Kauffman apparatus | ASTM C1260 | |
| 632 | Coal shales and silts E | Total carbon content Range (0,01 - 95,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
High-temperature combustion with IR detection | PN-ISO 10694 | |
| 633 | Coal shales and silts E | Total organic carbon (TOC) content Range (0,01 - 95,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
High-temperature combustion with IR detection | PN-ISO 10694 | |
| 634 | Coal shales and silts E | Total moisture content Range (1,0 - 90,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Gravimetric method | PB-4/BC | |
| 635 | Coal shales and silts E | Analytical moisture content Range (0,1 - 50,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Gravimetric method | PB-4/BC | |
| 636 | Coal shales and silts E | Moisture content in the air-dried sample Range (1,0 - 50,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Gravimetric method | PB-4/BC | |
| 637 | Coal shales and silts E | Free moisture content Range (1,0 - 50,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Gravimetric method | PB-4/BC | |
| 638 | Coal shales and silts E | Total moisture content (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
PB-4/BC | ||
| 639 | Coal shales and silts E | Gross calorific value Range (1000 - 20000) kJ/kg Net calorific value (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Calorimetric method | PB-3/BC | |
| 640 | Coal shales and silts E | Total sulfur content Range (0,01 - 5,0)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
High-temperature combustion with IR detection | PB-2/BC | |
| 641 | Building materials E | Gross calorific value Range (-3 - 40,00) MJ/kg Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Calorimetric method | PN-EN ISO 1716 „N” | |
| 642 | Granulated slag E | Content of granulated blast furnace slag in cements Range (0 - 100)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Optical microscopy method | PN-B-19707 Załącznik B | |
| 643 | Granulated slag E | Glassy phase content in granulated blast furnace slag Range (30 - 100)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011 |
Optical microscopy method | PN-B-19707 Załącznik C | |
| 644 | Cement E | Heat of hydration Range (50 - 500) J/g Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Semi-adiabatic method | PN-EN 196-9 | |
| 645 | Cement E | Resistance to sulphates Range (0,005 - 10)% Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Mortar expansion in sodium sulphate solution method | PN-B-19707 Załącznik A | |
| 646 | Building materials (cement, sand, binders, concrete, mortar, grout, aggregate, glass, limestone, lime) waste (10 01 01, 10 01 02, 10 02 01, 10 13 80, 17 01 01, 17 01 07) E | Leachability of heavy metals, Concentration range in the aqueous extract: As (0,05 - 100) mg/l, Cr (0,01 - 100) mg/l, Zn (0,01 - 100) mg/l, Pb (0,01 - 100) mg/l, Co (0,01 - 100) mg/l, Ni (0,01 - 100) mg/l, V (0,01 - 100) mg/l, Mo (0,01 - 100) mg/l, Cu (0,01 - 100) mg/l, Ba (0,005 - 100) mg/l, Cd (0,002 - 100) mg/l Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PB-8/BC | |
| 647 | Building materials (cement, sand, binders, concrete, mortar, grout, aggregate, glass, limestone, lime, microsilica), slags and ashes from the power industry, slags from the metallurgical industry and dusts E | Heavy metal content, Concentration range: As (10 - 20000) mg/kg, Cr (2 - 20000) mg/kg, Zn (2 - 20000) mg/kg, Pb (2 - 20000) mg/kg, Co (2 - 20000) mg/kg, Ni (2 - 20000) mg/kg, V (2 - 20000) mg/kg, Mo (2 - 20000) mg/kg, Cu (2 - 20000) mg/kg, Ba (1 - 20000) mg/kg, Cd (0,4 - 20000) mg/kg Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PB-10/BC | |
| Centre for Refractory Materials; Refractory Materials Research Group | |||||
| 648 | Silicon carbide and silicon carbide products and materials containing SiC | Free C content Range (0,01 - 1,0)% |
High-temperature combustion method with detection in IR | PN-EN ISO 21068-2:2010 pkt. 6.4.5 | |
| 649 | Refractory, ceramic and insulating raw materials and products, materials containing SiC and carbides, dusts and geological raw materials | Total S content Range (0,02 - 3,0)% |
High-temperature combustion with IR detection | PBA 43 wyd. 1 z dn. 27.07.2016 | |
| 650 | Refractory raw materials and materials and SiC | Content of WC, SiO2, Al2O3, Fe2O3, CaO, MgO, TiO2, ZrO2, Cr2 O3, K2O, Na2O, P2O5 SiO2 (0,01 - 100)% Al2O3 (0,01 - 100)% Fe2O3 (0,02 - 16,00)% CaO (0,02 - 98,00)% MgO (0,03 - 100)% TiO2 (0,01 - 50,00) % ZrO2 (0,02 - 92,00)% Cr2O3 (0,01 - 51,00)% K2O (0,01 - 4,00)% Na2O (0,01 - 4,00)% P2O5 (0,01 - 5,00)% WO3 (0,01 - 3,00)% |
Wavelength dispersive X-ray fluorescence spectrometry method (WDXRF) | PN-EN ISO 12677:2011 | |
| 651 | Refractory raw materials and materials and SiC | Loss on ignition Range (0,00 - 90,00)% |
Gravimetric method | PN-EN ISO 12677:2011 | PN-EN ISO 26845:2009 | |
| 652 | SiC and SiC products | Na, K content Na (0,01 - 0,5) % K (0,01 - 0,5) % |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | ISO 9286:2021 pkt. 4.7 | PN-EN ISO 11885:2009 | |
| 653 | Refractory materials and raw materials | Density | Pycnometric method | PN-EN 993-2:1997 | PN-EN 993-2:1997/A1:2004 | |
| 654 | Dense shaped materials (with total porosity up to 45 %) | Water absorption | Water method under vacuum | PN-92/H-04185 | |
| 655 | Dense shaped materials (with total porosity up to 45 %) | Apparent density, open and total porosity | Water method under vacuum | PN-EN 993-1:2019-01 | |
| 656 | Insulating refractory products (with total porosity not less than 45 %) | Apparent density and total porosity of insulating products Range od 45 % |
PN-EN 1094-4:1998 | ||
| 657 | Granular refractory materials and raw materials | Apparent density - Open porosity and water absorption of granular materials |
Water method under vacuum | PBC-4-1/wyd. 6 z dnia 18.01.2010 r. | |
| 658 | Unshaped refractory products: dense and insulating castables; ramming mixes | Permanent linear change | PN-EN ISO 1927-6:2013-06 | ||
| 659 | Unshaped refractory products: dense and insulating castables; ramming mixes | Geometric apparent density | PN-EN ISO 1927-6:2013-06 | ||
| 660 | Dense shaped refractory products (with a true porosity up to 45%) | Permanent change in dimensions due to heating, Linear measurement with a vernier caliper (Method 2) | PN-EN 993-10:2021-03 | ||
| 661 | Shaped insulating refractory products | Permanent change in dimensions due to heating | PN-EN 1094-6:2001 | ||
| 662 | Dense shaped refractory products (with a total porosity up to 45%) | Compressive strength at ambient temperature Range do 3000 kN |
PN-EN 993-5:2019-01 | ||
| 663 | Shaped insulating refractory products (with total porosity not less than 45%) | Compressive strength at ambient temperature Range do 400 kN |
PN-EN ISO 8895:2007 | ||
| 664 | Dense and insulating castables, ramming mixes – unshaped refractory products, Sample dimensions: 64x64 mm – dense castables and products 114x114 mm – insulating castables and products, Precast shapes and products made of dense and insulating castables and ramming mixes, Sample dimensions: 64x64 mm – dense castables and products 114x114 mm – insulating castables and products | Compressive strength at ambient temperature Range do 3000 kN |
PN-EN ISO 1927-6:2013-06 | ||
| 665 | Structural materials, ceramics, glass, composites, raw materials | Microstructure and surface morphology Qualitative analysis of chemical composition |
Scanning electron microscopy method; Scanning electron microscopy method with an EDS system | PBS-1 wyd. 1 z dnia 1.03.2014 | |
| 666 | Raw materials, refractory and construction products | Presence of asbestos fibres | Scanning electron microscopy method with an EDS system | ISO 22262-1:2012 | |
| 667 | Polycrystalline materials - solid - powdered, Amorphous materials (asbestos, chemicals, chemical products including fertilisers, construction products, building materials, structural materials excluding metals) - materials containing carbonates | Phase identification | X-ray diffraction method | PN-EN 13925-1:2007 z wyłączeniem pkt.7,5; 7,6; 7,7; 7,8; 7,9; 7,10; 7,11 | PN-EN 13925-2:2004 z wyłączeniem pkt.4,5; 6,3; 6,6 | |
| 668 | Single- and multi-phase materials and raw materials, including those containing an amorphous phase | Quantitative phase composition | X-ray diffraction method (Rietveld method) | PN-EN 13925-1:2007 z wyłączeniem pkt.7,5; 7,6; 7,7; 7,8; 7,9; 7,10; 7,11 | |
| 669 | Silica and aluminosilicate products and raw materials containing quartz, Aluminosilicate and corundum products and raw materials containing: corundum (α-Al2O3) | Quantitative phase composition | X-ray diffraction method – (External standard method) | PN-EN 13925-1:2007 z wyłączeniem pkt.7,5; 7,6; 7,7; 7,8; 7,9; 7,10; 7,11 | |
| 670 | Shaped refractory products: fired and unfired | Thermal expansion, Temperature range: from 400 °C to 1500°C | Differential method | PN-EN 993-19:2006 | |
| 671 | Shaped refractory products: fired and unfired | Compressive creep, Temperature range: from 400 °C to 1650°C | Differential method | PN-EN 993-9:1999 | |
| 672 | Shaped refractory products: fired and unfired | Refractoriness under load, Temperature range: from 400 °C to 1700 °C | Differential method | PN-EN ISO 1893:2009 | |
| 673 | Ceramic raw materials, including refractory materials, glazes, fluxes, slags | Characteristic temperatures Temperature range do 1600 °C |
Microscopic-photographic method | PBT-7-1/wyd. 7 z dnia 26.05.2010 r. | |
| Centre for Advanced Ceramics and Precast Products; Ceramics Research Group | |||||
| 674 | Calcium silicate masonry units | Water absorption | PN-EN 772-21:2011 | ||
| 675 | Calcium silicate masonry units | Compressive strength max load 2000 kN | PN-EN 772-1+A1:2015-10 | ||
| 676 | Calcium silicate masonry units | Net density, gross dry density | PN-EN 772-13:2001 | ||
| 677 | Calcium silicate masonry units | Dimensions | PN-EN 772-16:2011 | ||
| 678 | Calcium silicate masonry units | Freeze-thaw resistance in an automatic chamber temperature range: {(–15) - (+20)} °C | PN-EN 772-18:2011 | ||
| 679 | Clay masonry units | Compressive strength max load 2000 kN | PN-EN 772-1+A1:2015-10 | ||
| 680 | Clay masonry units | Active soluble salt content. Range Na (0,5 - 1) mg/l K (0,5 - 2) mg/ Mg (0,5 - 1) mg/l |
PN-EN 772-5:2016-06 | PN-EN 772-5:2016-06/AC:2017-08 | ||
| 681 | Clay masonry units | Water absorption Cold water absorption |
Boiling method | PN-EN 772-7:2000 | PN-EN 772-21:2011 | |
| 682 | Clay masonry units | Dimensions | PN-EN 772-16:2011 | ||
| 683 | Clay masonry units | Freeze-thaw resistance in an automatic chamber temperature range (–15°C) - (+20) °C |
PN-B-12012:2022-07 | ||
| 684 | Clay masonry units | Net density, gross dry density | PN-EN 772-13:2001 | ||
| 685 | Floor coverings | Critical slip angle | DIN EN 16165:2023-02 Annex A, B, NB | EN 16165:2021-10 Annex B | EN 16165:2021-10 Annex A | ||
| 686 | Ceramic tiles and slabs | Dimensions | PN-EN ISO 10545-2:2018-12 | ||
| 687 | Ceramic tiles and slabs | Surface quality | Visual method. | PN-EN ISO 10545-2:2018-12 | |
| 688 | Ceramic tiles and slabs | Water absorption | Method of saturating samples with water by boiling; Vacuum saturation method | PN-EN ISO 10545-3:1999 | PN-EN ISO 10545-3:2018-05 | |
| 689 | Ceramic tiles and slabs | Flexural strength and breaking force (0,5 – 4) kN | PN-EN ISO 10545-4:2019-04 | ||
| 690 | Ceramic tiles and slabs | Impact resistance | Method for measuring the reflectance coefficient | PN-EN ISO 10545-5:1999 | |
| 691 | Ceramic tiles and slabs | Resistance to deep abrasion, Unglazed tiles | PN-EN ISO 10545-6:2012 | ||
| 692 | Ceramic tiles and slabs | Surface abrasion resistance, Glazed tiles | PN-EN ISO 10545-7:2000 | ||
| 693 | Ceramic tiles and slabs | Linear thermal expansion Temperature range (25 - 100) °C |
PN-EN ISO 10545-8:2014-09 | ||
| 694 | Ceramic tiles and slabs | Resistance to thermal shock in the temperature range (15 - 145) °C | PN-EN ISO 10545-9:2013-12 | ||
| 695 | Ceramic tiles and slabs | Resistance to crazing for glazed tiles | PN-EN ISO 10545-11:1998 | ||
| 696 | Ceramic tiles and slabs | Frost resistance, testing in an automatic chamber {(–15) (+20)} °C |
PN-EN ISO 10545-12:1999 | ||
| 697 | Ceramic tiles and slabs | Chemical resistance | PN-EN ISO 10545-13:2017-01 | ||
| 698 | Ceramic tiles and slabs | Resistance to staining | PN-EN ISO 10545-14:2015-11 | ||
| 699 | Ceramic tiles and slabs | Content of released lead and cadmium Pb (0,1 - 20) mg/l Cd (0,02 - 3,0) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-EN ISO 10545-15:2021-11 „N” | |
| 700 | Ceramic tiles and slabs | Surface hardness on the Mohs scale | PN-EN 101:1994 | ||
| 701 | Ceramic tiles and slabs | Critical slip angle | DIN EN 16165:2023-02 Annex A, B, NB | EN 16165:2021-10 Annex B | EN 16165:2021-10 Annex A | ||
| 702 | Glass articles | Hydrolytic resistance of glass grains at 98°C Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Titrimetric method | PN–ISO 719:1994 | |
| 703 | Silicate surfaces. Articles intended to come into contact with foodstuffs | Content of released lead and cadmium Pb (0,1 - 20) mg/l Cd (0,02 - 3,0) mg/l Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Flame atomic absorption spectrometry (FAAS) | PN-EN 1388–1:2000+Ap1:2002 | PN-EN 1388–2:2000 | |
| 704 | Glass and ceramic tableware and kitchenware | Resistance to thermal shock Range (15 - 140) °C Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-A-13004:1997 p. 3.6. | PN-B-13113:1986 | ||
| 705 | Glass and ceramic tableware and kitchenware | Resistance to thermal shock Range (15 - 500) °C Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1183:2000 | ||
| 706 | Glass and ceramic tableware and kitchenware | Water absorption Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1217:2000 | ||
| 707 | Glass and ceramic tableware and kitchenware | Resistance to mechanical washing Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 12875-1:2008 | ||
| 708 | Glass and ceramic tableware and kitchenware | Surface quality of non-metallic products after mechanical washing Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Visual method | PN-EN 12875-2:2006 | |
| 709 | Building materials and raw materials | Radionuclide activity concentration Radionuclide activity concentration 40K Range (40 - 2000) Bq/kg Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Gamma-ray spectrometry | Poradnik ITB nr 455/2010 IL.1_1.10.03.21 | |
| 710 | Building materials and raw materials | Radionuclide activity concentration Radionuclide activity concentration 226Ra Range (3 - 1000) Bq/kg Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Gamma-ray spectrometry | Poradnik ITB nr 455/2010 IL.1_1.10.03.21 | |
| 711 | Building materials and raw materials | Radionuclide activity concentration Radionuclide activity concentration 208Tl Range (3 - 1000) Bq/kg Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Gamma-ray spectrometry | Poradnik ITB nr 455/2010 IL.1_1.10.03.21 | |
| 712 | Building materials and raw materials | Radionuclide activity concentration Radionuclide activity concentration 232Th (calculated) Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Poradnik ITB nr 455/2010 IL.1_1.10.03.21 | ||
| 713 | Building materials and raw materials | Radioactivity concentration indices I (calculated) Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Poradnik ITB nr 455/2010 IL.1_1.10.03.21 | ||
| 714 | Sanitary appliances – washbasins – WC pans – bidets – urinals | Dimensions | PN-EN 31+A1:2014-07 | PN-EN 33:2019-06 | PN-EN 35:2014-07 | PN-EN 80:2002 | ||
| 715 | Sanitary appliances – WC pans | Water absorption | PN-EN 997:2018-11 | ||
| 716 | Sanitary appliances – wash basins – baths – shower trays | Resistance to temperature changes Range (10 - 90) °C |
PN-EN 14688:2009 | PN-EN 14688+A1:2018-11 PN–EN 14516+A1:2012 | PN-EN 14516+A1:2018-12 PN–EN 14527+A1:2012 | PN-EN 14527+A1:2018-12 | ||
| 717 | Sanitary appliances – WC pans – washbasins – bidets | Resistance to load max load: 6 kN | PN-EN 997:2018-11 | PN-EN 14688:2009 | PN-EN 14688+A1:2018-11 | PN-EN 14528:2009 | PN-EN 14528+A1:2018-11 | ||
| 718 | Sanitary appliances – wash basins | Abrasion resistance | PN-EN 14688:2009 | PN-EN 14688+A1:2018-11 | ||
| 719 | Sanitary appliances – wash basins | Scratch resistance | PN-EN 14688:2009 | PN-EN 14688+A1:2018-11 | ||
| 720 | Sanitary appliances: – washbasins – bidets | Flow rate through the overflow orifice Range do 0,42 l/s |
PN-EN 14688:2009 | PN-EN 14688+A1:2018-11 | PN-EN 14528:2009 | PN-EN 14528+A1:2018-11 | ||
| 721 | Sanitary appliances – wash basins – baths – shower trays | Resistance to chemical and staining agents | PN-EN 14688:2009 | PN-EN 14688+A1:2018-11 PN–EN 14516+A1:2012 | PN-EN 14516+A1:2018-12 PN–EN 14527+A1:2012 | PN-EN 14527+A1:2018-12 | ||
| 722 | Kitchen sinks | Resistance to chemical and staining agents | PN-EN 13310:2005 | PN-EN 13310+A1:2018-11 | ||
| 723 | Kitchen sinks | Abrasion resistance | PN-EN 13310:2005 | PN-EN 13310+A1:2018-11 | ||
| 724 | Kitchen sinks | Scratch resistance | PN-EN 13310:2005 | PN-EN 13310+A1:2018-11 | ||
| 725 | Kitchen sinks | Flow rate through the overflow orifice Range do 0,42 l/s |
PN-EN 13310:2005 | PN-EN 13310+A1:2018-11 | ||
| 726 | Kitchen sinks | Resistance to temperature changes Range (10 - 90) °C |
PN-EN 13310:2005 | PN-EN 13310+A1:2018-11 | ||
| Centre for Advanced Ceramics and Precast Products; Aerated Concrete and Precast Products Research Group | |||||
| 727 | Concrete (normal-weight, lightweight, heavyweight) | Compressive strength range (100 - 3000) kN |
PN-EN 12390-3:2019-07 | ||
| 728 | Concrete (normal-weight, lightweight, heavyweight) | Flexural strength range (20 - 1000) kN |
PN-EN 12390-5:2019-08 | ||
| 729 | Concrete (normal-weight, lightweight, heavyweight) | Water absorption | PN-88/B-06250 | ||
| 730 | Concrete (normal-weight, lightweight, heavyweight) | Resistance to freezing | PN-88/B-06250 p. 6.5.1 | ||
| 731 | Concrete (normal-weight, lightweight, heavyweight) | Depth of penetration of water under pressure | PN-EN 12390-8:2019-08 | ||
| 732 | Natural stone | Abrasion resistance | Böhme disc method | PN-EN 14157:2017-11 | |
| 733 | Aggregate concrete masonry units (small-sized wall units) | External appearance: flatness of the face surfaces |
PN-EN 772-20:2002+A1: 2005 | ||
| 734 | Aggregate concrete masonry units (small-sized wall units) | Dimensions: length, width, height | PN-EN 772-16:2011 | ||
| 735 | Aggregate concrete masonry units (small-sized wall units) | Density: net in dry state gross in dry state |
PN-EN 772-13:2001, p. 7.1, 7.2 | PN-EN 772-13:2001, p. 7.1, 7.3 | ||
| 736 | Aggregate concrete masonry units (small-sized wall units) | Compressive strength Range (100 - 3000) kN |
PN-EN 772-1:2015-10 | ||
| 737 | Aggregate concrete masonry units (small-sized wall units) | Frost resistance | PN-B-19306:2004 | PN-B-19307:2004 | ||
| 738 | Aggregate concrete masonry units (small-sized wall units) | Water absorption | PN-EN 772-11:2011 | ||
| 739 | Aggregate concrete masonry units (small-sized wall units) | Linear changes | PN-EN 772-14:2002 | ||
| 740 | Concrete paving block | Water absorption | PN-EN 1338:2005 załącznik E | ||
| 741 | Concrete paving block | Abrasion resistance | Method: on the Böhme disc | PN-EN 1338:2005 załącznik H | |
| 742 | Concrete paving block | Freeze/thaw resistance | PN-EN 1338:2005 załącznik D | ||
| 743 | Concrete paving block | Splitting tensile strength range (50 - 950) kN |
PN-EN 1338:2005 załącznik F | ||
| 744 | Kerbs | Water absorption | PN-EN 1340:2004 załącznik E | ||
| 745 | Kerbs | Abrasion resistance | Böhme disc method | PN-EN 1340:2004 załącznik H | |
| 746 | Kerbs | Freeze/thaw resistance | PN-EN 1340:2004 załącznik D | ||
| 747 | Kerbs | Flexural strength range (20 - 1000) kN |
PN-EN 1340:2004 załącznik F | ||
| 748 | Lintels excluding steel lintels | Water absorption (capillary rise) – absorption coefficient Range (0 - 10) g/m2-s Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Gravimetric method | PN-EN 772-11:2011 | |
| 749 | Lintels excluding steel lintels | Shear load-bearing capacity range (20 - 100) kN Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 846-9:2016-06 „N” | ||
| 750 | Lintels excluding steel lintels | Bending load capacity range (20 - 100) kN Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 846-9:2016-06 „N” | ||
| 751 | Lintels excluding steel lintels | Deflection Range (0 - 25) mm Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Method: direct measurement | PN-EN 846-9:2016-06 „N” | |
| 752 | Lintels excluding steel lintels | Geometric dimensions: Range (0 - 5000) mm Deviations from straightness Range (0 - 10) mm Thickness of the reinforcement cover Range (0 - 80) mm Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Direct measurement method Length, width, height | PN-EN 846-11:2002 | |
| 753 | Pipes and fittings (non-pressure): - concrete - reinforced concrete | Compressive strength of core drilled specimens range (100 - 3000) kN Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 12504-1:2019-08 | PN-EN 12390-3:2019-07 | ||
| 754 | Covering elements of manholes and inspection chambers made of concrete (unreinforced and steel fibre reinforced) and reinforced concrete | Compressive strength of core drilled specimens Range (100 - 3000) kN Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 12504-1:2019-08 | ||
| 755 | Components of drainage channels for pedestrian and vehicular areas - channels - gratings and covers | Strength (proof loads) range (100 - 3000) kN Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1433:2005+A1:2007 „N” | ||
| 756 | Components of drainage channels for pedestrian and vehicular areas - channels - gratings and covers | Water absorption (absorptivity) Range (0 - 10)% Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Method: gravimetric | PN-EN 1433:2005+A1:2007 | |
| 757 | Components of drainage channels for pedestrian and vehicular areas - channels - gratings and covers | Freeze/thaw resistance in de-icing salt Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Method: gravimetric | PN-EN 1433:2005+A1:2007 „N” | |
| 758 | Components of drainage channels for pedestrian and vehicular areas - channels - gratings and covers | Watertightness Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1433:2005+A1:2007 „N” | ||
| 759 | Components of drainage channels for pedestrian and vehicular areas - channels - gratings and covers | Strength (proof loads) Range (100 - 3000) kN Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 1433:2005+A1:2007 „N” | ||
| 760 | Components of drainage channels for pedestrian and vehicular areas - channels - gratings and covers | Permanent deformation Range (0 - 12) mm Regulated area: „N” - Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Method: direct measurement | PN-EN 1433:2005+A1:2007 „N” | |
| 761 | Precast building products of autoclaved aerated concrete, Small-sized units | Dimensions: length, width, height Range do 1000 mm |
PN-EN 772-16:2011 | ||
| 762 | Precast building products of autoclaved aerated concrete, Small-sized units | Surface flatness diagonal do 1000 mm |
PN-EN 772-20:2002+A1:2005 | ||
| 763 | Precast building products of autoclaved aerated concrete, Small-sized units | Parallelism of surfaces height do 300 mm |
PN-EN 772-16:2011 | ||
| 764 | Precast building products of autoclaved aerated concrete, Small-sized units | Density: net in dry state gross in dry state |
PN-EN 772-13:2001 | ||
| 765 | Precast building products of autoclaved aerated concrete, Small-sized units | Compressive strength: Range (2 - 200) kN |
PN-EN 772-1+A1:2015-10 | ||
| 766 | Precast building products of autoclaved aerated concrete, Small-sized units | Freeze/thaw resistance | PN-EN 15304:2010 | ||
| 767 | Precast building products of autoclaved aerated concrete, Small-sized units | Thermal conductivity Range (0,005 - 0,5) W/mK |
PN-ISO 8301:1998 | ||
| 768 | Construction products, building materials and masonry units: - autoclaved aerated concrete - precast building products | Radionuclide activity concentration Radionuclide activity concentration 40K Range (40 - 2000) Bq/kg |
Gamma-ray spectrometry | Poradnik ITB nr 455/2010 IL.1_1.10.03.21 | |
| 769 | Construction products, building materials and masonry units: - autoclaved aerated concrete - precast building products | Radionuclide activity concentration Radionuclide activity concentration 226Ra Range (3 - 1000) Bq/kg |
Gamma-ray spectrometry | Poradnik ITB nr 455/2010 IL.1_1.10.03.21 | |
| 770 | Construction products, building materials and masonry units: - autoclaved aerated concrete - precast building products | Radionuclide activity concentration Radionuclide activity concentration 208Tl Range (3 - 1000) Bq/kg |
Gamma-ray spectrometry | Poradnik ITB nr 455/2010 IL.1_1.10.03.21 | |
| 771 | Construction products, building materials and masonry units: - autoclaved aerated concrete - precast building products | Radionuclide activity concentration: 232Th (calculated) | Poradnik ITB nr 455/2010 IL.1_1.10.03.21 | ||
| 772 | Construction products, building materials and masonry units: - autoclaved aerated concrete - precast building products | Radioactivity concentration indices I (calculated) | Poradnik ITB nr 455/2010 IL.1_1.10.03.21 | ||
| 773 | Autoclaved aerated concrete | Net dry density | PN-EN 772-13:2001 | ||
| 774 | Autoclaved aerated concrete | Compressive strength Range (2 - 200) kN |
PN-EN 772-1:2015-10 | ||
| 775 | Autoclaved aerated concrete | Freeze/thaw resistance | PN-EN 15304:2010 | ||
| 776 | Autoclaved aerated concrete | Shrinkage Range do 25 mm |
Graf-Kaufman method | PN-EN 680:2008 | |
| 777 | Autoclaved aerated concrete | Thermal conductivity Range (0,005 - 0,5) W/mK |
PN-ISO 8301:1998 | ||
| 778 | Autoclaved aerated concrete | Water absorption | PN-EN 772-11:2011 | ||
| 779 | Autoclaved aerated concrete | Water vapour permeability | PN-EN ISO 12572:2016-10 | PN-EN 772-15:2002 | ||
| 780 | Construction products and materials - autoclaved aerated concrete - expanded polystyrene | Water vapour permeability | PN-EN ISO 12572:2016-10 | ||
| 781 | Construction products and materials - autoclaved aerated concrete - expanded polystyrene | Thermal conductivity Range (0,005 - 0,5) W/mK |
PN-ISO 8301:1998 | ||
| 782 | Masonry, including ancillary products for masonry | Shear strength Range do 200 kN Bend test |
PN-EN 1052-3:2004 | PN-EN 1052-3:2004/A1:2009 | ||
| 783 | Admixtures for concrete | Total chlorine Range (0,005 - 1,00)% |
Titrimetric method | PN-EN ISO 1158:1999 | |
| 784 | Admixtures for concrete | Water-soluble chlorides Range (0,005 - 1,00)% |
Titrimetric method | PN-EN 480-10:2011 | |
| 785 | Metal products: - steel bars for the reinforcement of concrete - welded steel lattice girders - welded steel fabric | Shear force of the welded joint - Fs force (3 - 100) kN |
Method: shear test | PN-EN 10080:2007 pkt. 9.3 | PN-EN lSO 15630-2:2019-04E pkt 7 | |
| 786 | Metal products: - steel bars for the reinforcement of concrete - welded steel lattice girders - welded steel fabric | Mechanical properties: -distinct yield strength Re, proof strength, plastic extension Rp, tensile strength Rm, percentage elongation after fracture A, percentage total extension at maximum force Agt, force (3 - 1000) kN elongation ( 0,01 - 23,00) mm |
Method: tensile test at room temperature | PN-EN lSO 6892-1:2016 Metoda B | PN-EN lSO 6892-1:2020-05 Metoda B | PN-EN lSO 15630-1:2019-04E pkt 5 | PN-EN lSO 15630-2:2019-04E pkt 5 | |
| 787 | Metal products: - steel bars for the reinforcement of concrete - welded steel lattice girders - welded steel fabric | Geometry of the ribbed surface: rib height Range (0 - 3) mm spacing between ribs Range (0 - 150) mm inclination angle of the transverse rib Range (0° - 90°) |
Method: direct measurement | PN-EN lSO 15630-1:2019-04E pkt 10.3.1, 10.3.3, 10.3.6 | |
| 788 | Metal products: - steel bars for the reinforcement of concrete - welded steel lattice girders - welded steel fabric | Mass per unit length Range (0 - 16) kg, Range (0 - 1000) mm |
Method: indirect measurement | PN-EN lSO 15630-1:2019-04E pkt 12 | |
| 789 | Metal products: - steel bars for the reinforcement of concrete - welded steel lattice girders - welded steel fabric | Bend test through an angle of 60° on a mandrel of diameter 6d at a temperature of (10 – 35) oC | PN-EN ISO 15630-2:2019-04 pkt.6 | ||
| Centre for Environmental Engineering | |||||
| 790 | Waste gases | Gas volume flow rate for dynamic pressures >10 Pa Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Stagnation pressure method | PN-Z-04030-7:1994 | |
| 791 | Waste gases | Sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-Z-04030-7:1994 | ||
| 792 | Waste gases | Dust concentration Range (0,001 – 100) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Gravimetric method | PN-Z-04030-7:1994 | |
| 793 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-Z-04030-7:1994 | ||
| 794 | Waste gases | Concentration of: CO2, SO2 CO2 (0,5 - 20) % SO2 (6 - 700) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Non-dispersive infrared spectrometry (NDIR) | PN-ISO 10396:2001 | |
| 795 | Waste gases | Concentration of: O2, CO, CO2, NO, NO2, SO2 O2 (0,5 - 20)% CO (5 - 1200) mg/m3 CO2 (0,5 - 23)% NO (2,1 - 640) mg/m3 NO2 (7,4 - 200) mg/m3 SO2 (10 - 700) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Method using a zirconia cell; Fourier transform infrared spectrometry method (FT-IR) | PN-ISO 10396:2001 | |
| 796 | Waste gases | Emission of CO, NO, NO2, SO2 (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-ISO 10396:2001 | ||
| 797 | Waste gases | O2 concentration Range (0,52 - 20)% Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Paramagnetic method | PN-EN 14789:2006 | |
| 798 | Waste gases | CO concentration Range (5 - 1200) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15058:2006 | |
| 799 | Waste gases | CO emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 15058:2006 | ||
| 800 | Waste gases | Sampling for determination of SO2 concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 14791:2017-04 | ||
| 801 | Waste gases | SO2 concentration Range (5 - 2000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Thoron method | PN-EN 14791:2017-04 | |
| 802 | Waste gases | SO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 14791:2017-04 | ||
| 803 | Waste gases | Water vapour concentration in flue ducts – H2O concentration Range (4 - 35)% objętości Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Condensation adsorption method | PN-EN 14790:2017-04 | |
| 804 | Waste gases | NOx concentration Range (3 - 980) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Chemiluminescence method (CLD) | PN-EN 14792:2006 | |
| 805 | Waste gases | NOx emission (NO and NO2 expressed as NO2) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 14792:2006 | ||
| 806 | Waste gases | Sampling for determination of HCl Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 1911:2011 | ||
| 807 | Waste gases | HCl concentration Range (0,3 - 2058) mg/m3 Range (0,05 - 200) mg w próbce Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Ion chromatography (IC) | PN-EN 1911:2011 | |
| 808 | Waste gases | HCl emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 1911:2011 | ||
| 809 | Waste gases | Sampling for determination of HF Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
ISO 15713:2006 | ||
| 810 | Waste gases | HF concentration Range (0,13 - 1289,50) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Ionometric method) | ISO 15713:2006 | |
| 811 | Waste gases | HF emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
ISO 15713:2006 | ||
| 812 | Waste gases | Sampling for the determination of PCDD/PCDF mass concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Filtration-condensation method | PN-EN 1948-1:2006 | |
| 813 | Waste gases | PCDD/PCDF emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 1948-1:2006 | ||
| 814 | Waste gases | Sampling for determination of metals, As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 14385:2025-05 | ||
| 815 | Waste gases | Element concentrations (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V) Range (0,000002 - 2,0) mg/m3 Range (0,00001 - 0,5) mg w próbce Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN 14385:2025-05 | |
| 816 | Waste gases | Emission, As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 14385:2025-05 | ||
| 817 | Waste gases | Sampling for the determination of total mercury concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 13211+AC:2006 | ||
| 818 | Waste gases | Total mercury emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 13211+AC:2006 | ||
| 819 | Waste gases | Concentration of organic substances in the form of gases and vapours expressed as total gaseous organic carbon Range (3,3 - 500) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Continuous flame ionization detection method | PN-EN 12619:2013-05 | |
| 820 | Waste gases | Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 12619:2013-05 | ||
| 821 | Waste gases | NH3 concentration Range (2,2 - 46) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Fourier transform infrared spectrometry (FT-IR) | PN-ISO 10396:2001 | |
| 822 | Waste gases | NH3 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-ISO 10396:2001 | ||
| 823 | Waste gases | Concentration/content of ammonia NH3 Range (0,004 - 4,72) mg w próbce NH3 Range (0,05 - 52,5) mg/m3 NH3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Spectrometric method | Annex B EN-ISO 21887:2019 | PN-ISO 7150-1:2002 | |
| 824 | Waste gases | NH3 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Annex B EN-ISO 21887:2019 | PN-ISO 7150-1:2002 | ||
| 825 | Waste gases | Sampling for determination of the mass concentration, NH3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
ISO 21877:2017 | ||
| 826 | Waste gases | NH3 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
ISO 21877:2017 | ||
| 827 | Waste gases | Sampling for determination of ammonia concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Aspiration method using absorbing solutions | PB-LL-5 wyd. 1 z 30.03.2016 r. | |
| 828 | Waste gases | Sampling for determination of metals (Al, Ba, Sn, Zn, Fe, Mo) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 14385:2025-05 | PN-EN ISO 17294-2:2024-04 | ||
| 829 | Waste gases | Element concentrations (Al, Ba, Sn, Zn, Fe, Mo) Range (0,000002 - 2,0) mg/m3 Range (0,00001 - 0,5) mg w próbce Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN 14385:2025-05 | PN-EN ISO 17294-2:2024-04 | |
| 830 | Waste gases | Emission of Al, Ba, Sn, Zn, Fe, Mo (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 14385:2025-05 | PN-EN ISO 17294-2:2024-04 | ||
| 831 | Waste gases | Sampling for determination of the mass concentration of dioxin-like PCB Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Filtration-condensation method | PN-EN 1948-4+A1:2014-03 | |
| 832 | Waste gases | Emission of dioxin-like PCB (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 1948-4+A1:2014-03 | ||
| 833 | General environment - waste gas samples collected into absorbing solutions | Element content Antimony (0,00001 - 0,5) mg in the sample Arsenic (0,00001 - 0,5) mg in the sample Barium (0,00001 - 0,5) mg in the sample Chromium (0,00001 - 0,5) mg in the sample Tin (0,00001 - 0,5) mg in the sample Zinc (0,00001 - 0,5) mg in the sample Aluminium (0,00001 - 0,5) mg in the sample Cadmium (0,00001 - 0,5) mg in the sample Cobalt (0,00001 - 0,5) mg in the sample Manganese (0,00001 - 0,5) mg in the sample Copper (0,00001 - 0,5) mg in the sample Molybdenum (0,00001 - 0,5) mg in the sample Nickel (0,00001 - 0,5) mg in the sample Lead (0,00001 - 0,5) mg in the sample Thallium (0,00001 - 0,5) mg in the sample Vanadium (0,00001 - 0,5) mg in the sample Iron (0,00001 - 0,5) mg in the sample Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN 14385:2025-05 | PN-EN ISO 17294-2:2024-04 | |
| 834 | General environment - waste gas samples collected into absorbing solutions | Mercury (Hg) content Range (0,1 - 500) μg w próbce Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Mercury cold vapour atomic absorption spectrometry (CVAAS) | PN-EN 13211+AC:2006 | PN-EN ISO 12846:2012 | |
| 835 | General environment *) - waste gas samples collected on filters | Element content Antimony Range (0,0000025 - 2,5) mg w próbce Barium (0,0000025 - 2,5) mg in the sample Arsenic (0,0000025 - 2,5) mg in the sample Chromium (0,0000025 - 2,5) mg in the sample Tin (0,0000025 - 2,5) mg in the sample Zinc (0,0000025 - 2,5) mg in the sample Aluminium (0,0000025 - 2,5) mg in the sample Cadmium (0,0000025 - 2,5) mg in the sample Cobalt (0,0000025 - 2,5) mg in the sample Manganese (0,0000025 - 2,5) mg in the sample Copper (0,0000025 - 2,5) mg in the sample Molybdenum (0,0000025 - 2,5) mg in the sample Nickel (0,0000025 - 2,5) mg in the sample Lead (0,0000025 - 2,5) mg in the sample Thallium (0,00005 - 50) mg in the sample Vanadium (0,0000025 - 2,5) mg in the sample Iron (0,0000025 - 2,5) mg in the sample |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN 14385:2005-05 | PN-EN ISO 17294-2:2016-11 | |
| 836 | General environment *) - waste gas samples collected on filters | Mercury (Hg) content Range (0,25 - 500) μg w próbce |
Mercury cold vapour atomic absorption spectrometry (CVAAS) | PN-EN 13211+AC:2006 | PN-EN ISO 12846:2012 | |
| 837 | Waste gas dedusting equipment | Dust concentration Range (0,001 - 100) g/m3 |
Gravimetric method | PN-Z-04030-7:1994 | PN-M-34129:1987 metoda A | |
| 838 | Waste gas dedusting equipment | Dust removal efficiency (calculated) | PN-Z-04030-7:1994 | PN-M-34129:1987 metoda A | ||
| 839 | Automated Measuring Systems (AMS) | Calibration (QAL2) for: dust, SO2, NOx, CO, O2, CO2, TVOC, HCl, HF, H2O Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 14181:2015 | ||
| 840 | Automated Measuring Systems (AMS) | Annual surveillance tests (AST) for: dust, SO2, NOx, CO, O2, CO2, TVOC, HCl, HF, H2O Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
PN-EN 14181:2015 | ||
| 841 | Automated Measuring Systems (AMS) | SO2 concentration Range (5 - 2000) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Thoron method | PN-EN 14791:2017-04 | |
| 842 | Automated Measuring Systems (AMS) | HCl concentration Range (0,3 - 2058) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Ion chromatography (IC) | PN-EN 1911:2011 | |
| 843 | Automated Measuring Systems (AMS) | HF concentration Range (0,13 - 1289,50) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Ionometric method | ISO 15713:2006 | |
| 844 | Automated Measuring Systems (AMS) | Dust concentration Range (0,001 - 100) g/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Gravimetric method | PN-Z-04030-7:1994 | |
| 845 | Automated Measuring Systems (AMS) | O2 concentration Range (0,52 - 20)% Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Paramagnetic method | PN-EN 14789:2006 | |
| 846 | Automated Measuring Systems (AMS) | NOx concentration Range (3 - 980) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Chemiluminescence method (CLD) | PN-EN 14792:2006 | |
| 847 | Automated Measuring Systems (AMS) | CO concentration Range (5 - 1200) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15058:2006 | |
| 848 | Automated Measuring Systems (AMS) | CO2 concentration Range (0,5 - 20)% Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Non-dispersive infrared spectrometry (NDIR) | PN-ISO 10396:2001 | |
| 849 | Automated Measuring Systems (AMS) | Concentration of organic substances in gaseous and vapour form expressed as total gaseous organic carbon Range (3,3 - 500) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Continuous flame ionization detection method | PN-EN 12619: 2013-05 | |
| 850 | Automated Measuring Systems (AMS) | Water vapour concentration in flue ducts – H2O concentration Range (4 - 35)% objętości Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law (i.e. Dz.U. z 2021 r. poz. 1973 z późn. zm.) |
Condensation adsorption method | PN-EN 14790:2017-04 | |
| 851 | Automated Measuring Systems (AMS) | Calibration (QAL2) for: NH3 | PN-EN 14181:2015 | ||
| 852 | Automated Measuring Systems (AMS) | Annual surveillance tests (AST) for: NH3 | PN-EN 14181:2015 | ||
| 853 | Automated Measuring Systems (AMS) | NH3 concentration Range (2,2 - 46) mg/m3 |
Fourier transform infrared spectrometry (FT-IR) | PN-ISO 10396:2001 | |
| 854 | Landfill gases *), Biogas | Gas concentrations CO2, O2, CH4 CH4 (0,2 - 100,0)% CO2 (0,2 - 100,0)% O2 Range (0,1 - 25,0)% Flow velocity Range (0,6 - 30,0) m/s |
Infrared detection method (IR); Electrochemical method; Anemometric method | PB-LL-6 wyd. 1 z 15.03.2016 r. | |
| 855 | Water | Sampling for chemical and physical testing | PN-ISO 5667-4:2017-10 z wył. pkt.14,15,16 | PN-ISO 5667-6:2016-12 z wył. pkt. 7.5, 7.6, 8.2 | PN-ISO 5667-11:2017-10 z wył. pkt. 5.2, 6.2, 6.3 | ||
| 856 | Wastewater | Sampling for chemical and physical testing | Manual method | PN-ISO 5667-10:2021-11 | |
| 857 | Water, Wastewater | pH Range 2,0 - 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 858 | Water, Wastewater | Electrical conductivity Range (80,0 - 15 000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 859 | Water, Wastewater | Dry residue Range (10,0 - 1000) mg/l |
Gravimetric method | PB-LL-2 wyd. 1 z 15.03.2016 r. | |
| 860 | Water, Wastewater | Dissolved solids Range (10,0 - 1000) mg/l |
Gravimetric method | PB-LL-2 wyd. 1 z 15.03.2016 r. | |
| 861 | Water, Wastewater | Total dissolved solids Range (10,0 - 50 000) mg/l |
Gravimetric method | PN-EN 15216:2022-03 | |
| 862 | Water, Wastewater | Total suspended solids *) Range (2,0 - 2000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 863 | Water, Wastewater | Bromide concentration Range (0,1 - 400) mg/l |
Ion chromatography (IC) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 864 | Water, Wastewater | Chloride concentration Range (0,5 - 2000) mg/l |
Ion chromatography (IC) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 865 | Water, Wastewater | Fluoride concentration Range (0,05 - 200) mg/l |
Ion chromatography method (IC | PN-EN ISO 10304-1:2009+AC:2012 | |
| 866 | Water, Wastewater | Nitrite concentration Range (0,03 - 120) mg/l |
Ion chromatography (IC) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 867 | Water, Wastewater | Nitrate concentration Range (0,2 - 800) mg/l |
Ion chromatography (IC) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 868 | Water, Wastewater | Phosphate concentration Range (0,13 - 500) mg/l |
Ion chromatography (IC) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 869 | Water, Wastewater | Sulfate concentration Range (0,5 - 2000) mg/l |
Ion chromatography (IC) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 870 | Water, Wastewater | Ammonium ion concentration Range (0,05 - 200) mg/l |
Ion chromatography (IC) | PN-EN ISO 14911:2002 | |
| 871 | Water, Wastewater | Calcium concentration Range (1,0 - 4000) mg/l |
Ion chromatography (IC) | PN-EN ISO 14911:2002 | |
| 872 | Water, Wastewater | Magnesium concentration Range (1,0 - 4000) mg/l |
Ion chromatography (IC) | PN-EN ISO 14911:2002 | |
| 873 | Water, Wastewater | Sodium concentration Range (0,5 - 2000) mg/l |
Ion chromatography (IC) | PN-EN ISO 14911:2002 | |
| 874 | Water, Wastewater | Potassium concentration Range (0,5 - 2000) mg/l |
Ion chromatography (IC) | PN-EN ISO 14911:2002 | |
| 875 | Water, Wastewater | Lithium concentration Range (0,05 - 200) mg/l |
Ion chromatography (IC) | PN-EN ISO 14911:2002 | |
| 876 | Water, Wastewater | Element concentration Antimony (0,00005 - 50) mg/l Arsenic (0,00005 - 50) mg/l Barium (0,00005 - 50) mg/l Beryllium (0,00005 - 50) mg/l Chromium (0,00005 - 50) mg/l Zinc (0,00005 - 50) mg/l Aluminium (0,00005 - 50) mg/l Cadmium (0,00005 - 50) mg/l Cobalt (0,00005 - 50) mg/l Manganese (0,00005 - 50) mg/l Molybdenum (0,00005 - 50) mg/l Copper (0,00005 - 50) mg/l Nickel (0,00005 - 50) mg/l Lead (0,00005 - 50) mg/l Selenium (0,00005 - 50) mg/l Thallium (0,00005 - 50) mg/l Vanadium (0,00005 - 50) mg/l Iron (0,00005 - 50) mg/l |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN ISO 17294-2:2024-04 | |
| 877 | Water, Wastewater | Total organic carbon TOC concentration Range (1,00 - 1000) mg/l |
High-temperature combustion with IR detection | PN-EN 1484:1999 | |
| 878 | Water, Wastewater | Dissolved organic carbon DOC concentration Range (1,00 - 1000) mg/l |
High-temperature combustion with IR detection | PN-EN 1484:1999 | |
| 879 | Water, Wastewater | Metal concentrations Na (0,40 - 500) mg/l K (0,40 - 500) mg/l |
Flame atomic emission spectrometry (FEAS) | PN-ISO 9964-3:1994 | PN-ISO 9964-3/Ak:1997 | |
| 880 | Water, Wastewater | Mercury (Hg) concentration Range (0,0007 - 0,5) mg/l |
Atomic absorption spectrometry with amalgamation technique | PB-LL-20 wyd. 1 z 07.03.2016 r. | |
| 881 | Water, Wastewater | Mercury (Hg) concentration Range (0,0005 - 0,5) mg/l |
Mercury cold vapour atomic absorption spectrometry (CVAAS) | PN-EN ISO 12846:2012 | |
| 882 | Water, Wastewater | Total phosphorus concentration Range (0,04 - 20,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 | |
| 883 | Water, Wastewater | Chromium(VI) concentration Range (0,010 - 5,00) mg/l |
Spectrophotometric method | PN-C-04604-08:1977 | |
| 884 | Water | Chromium(VI) concentration Range (0,010 - 5,00) mg/l |
Spectrophotometric method | PN-EN ISO 18412:2007 | |
| 885 | Waste code: 19 12 10; 19 12 12; 20 01 38; 20 03 01 | Sampling for physical and chemical testing Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue |
PN-ISO 21645:2021-09 | ||
| 886 | Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 04, 19 06 06, 19 06 99, 19 08 05, 19 12 10, 19 12 12, 20 01 08, 20 01 37, 20 01 38, 20 0201, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 99 | Sampling for physical and chemical testing Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue |
PN-Z-15011-1:1998 | ||
| 887 | Waste code: 20 03 01, 19 12 12 | Morphological composition Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue |
Gravimetric method | PN-Z-15006:1993 | |
| 888 | Waste code: 19 05 01, 19 05 02, 19 05 03, 19 05 99, 19 06 04, 19 06 06, 19 06 99, 19 08 01, 19 08 02, 19 08 05, 19 12 10, 19 12 12, 20 01 08, 20 01 37, 20 01 38, 20 02 01, 20 02 02, 20 02 03, 20 03 01, 20 03 02, 20 03 03, 20 03 07, 20 03 99 | Oxygen demand (AT4) Range (1 - 80) mg/g O2 Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue |
Manometric method | PB-LL-4 wyd. 1 z 30.03.2016 r. | |
| 889 | Waste code: 06 09 80; 06 09 81; 07 02 12; 07 02 13; 10 01 01; 10 01 02; 10 01 05; 10 01 80; 15 01 02; 15 01 05; 15 01 09; 16 01 19; 17 02 03; 19 08 05; 19 12 04; 19 12 08; 19 12 10; 20 01 39; 20 02 02 | Mercury (Hg) content Range (0,005 - 100,0) mg/kg Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue |
Atomic absorption spectrometry with amalgamation technique | PB-LL-10 wyd. 3 z 29.11.2019 r. | |
| 890 | Solid fuels: secondary fuel – alternative fuel, solid recovered fuel (SRF) | Sampling for physical and chemical testing | PN-EN ISO 21645:2021-09 | ||
| 891 | Solid fuels: secondary fuel – alternative fuel, solid recovered fuel (SRF) | Total moisture content Range (0,5 - 80,0)% |
Gravimetric method | CEN/TS 15414-1:2010 | |
| 892 | Solid fuels: secondary fuel – alternative fuel, solid recovered fuel (SRF) | Volatile matter content Range (4,0 - 90,0)% |
Gravimetric method | PN-EN ISO 22167:2021-08 | |
| 893 | Solid fuels: secondary fuel – alternative fuel, solid recovered fuel (SRF) | Biodegradable fraction content – mass fraction of biomass by the C14 carbon isotope method. Non-biodegradable fraction content – mass fraction of non-biomass by the C14 carbon isotope method Range (5 - 100)% |
Liquid scintillation method | PN-EN ISO 21644:2021-07 | |
| 894 | Solid fuels: secondary fuel – alternative fuel, solid recovered fuel (SRF) | Biodegradable fraction content – mass fraction of biomass Non-biodegradable fraction content – mass fraction of non-biomass Range (5 - 100)% |
Selective dissolution method | PN-EN ISO 21644:2021-07 | |
| 895 | Solid fuels: solid biomass - solid biofuel | Total organic carbon TOC content Range (1,0 - 50)% |
High-temperature combustion with IR detection | PN-EN 15936:2022-07 | |
| 896 | Solid fuels: solid biomass - solid biofuel | Total carbon TC content Range (10 - 70)% |
High-temperature combustion with TCD detection | PN-EN ISO 16948:2015-07 | |
| 897 | Solid fuels: solid biomass - solid biofuel | Biodegradable fraction content – mass fraction of biomass by the C14 carbon isotope method. Non-biodegradable fraction content – mass fraction of non-biomass by the C14 carbon isotope method Range (5 - 100)% |
Liquid scintillation method | PN-EN ISO 21644:2021-07 | |
| 898 | Solid fuels: solid biomass - solid biofuel | Dry matter Range (35 - 99)% |
Gravimetric method | PN-EN 15934:2013-02 | |
| 899 | Solid fuels: solid biomass - solid biofuel | Total moisture content Range (1,0 - 54,0)% |
Gravimetric method | PN-EN ISO 18134-1:2023-02 | PN-EN ISO 18134-2:2024-10 | |
| 900 | Solid fuels: solid biomass - solid biofuel | Moisture content in the analytical sample Range (1,0 - 65)% |
Gravimetric method | PN-EN ISO 18134-3:2023-12 | |
| 901 | Solid fuels: solid biomass - solid biofuel | Ash content Range (0,3 - 12)% |
Gravimetric method | PN-EN ISO 18122:2023-05 | |
| 902 | Solid fuels: solid biomass - solid biofuel | Element content Antimony (0,25 - 2500) mg/kg Arsenic (0,25 - 2500) mg/kg Barium (0,25 - 2500) mg/kg Beryllium (0,25 - 2500) mg/kg Chromium (0,25 - 2500) mg/kg Zinc (0,25 - 2500) mg/kg Cadmium (0,25 - 2500) mg/kg Cobalt (0,25 - 2500) mg/kg Manganese (0,25 - 2500) mg/kg Copper (0,25 - 2500) mg/kg Molybdenum (0,25 - 2500) mg/kg Nickel (0,25 - 2500) mg/kg Lead (0,25 - 2500) mg/kg Selenium (0,25 - 2500) mg/kg Thallium (0,25 - 2500) mg/kg Vanadium (0,25 - 2500) mg/kg |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN ISO 16968:2015-07 | PN-EN ISO 17294-2:2024-04 | |
| 903 | Solid fuels: hard coal | First-stage moisture content (transient moisture) Range (0,5 - 50,0)% |
Gravimetric method | PN-ISO 589:2006 Metoda A2 | |
| 904 | Solid fuels: hard coal | Second-stage moisture content (moisture remaining in the sample) Range (0,5 - 20,0)% |
Gravimetric method | PN-ISO 589:2006 Metoda A2 | |
| 905 | Solid fuels: hard coal | Total moisture content (calculated) | PN-ISO 589:2006 Metoda A2 | ||
| 906 | Solid fuels: hard coal | Total moisture content Range (5,0 - 50,0)% |
Gravimetric method | PN-ISO 589:2006 Metoda B2 | |
| 907 | Solid fuels: hard coal, lignite, coke | Free moisture content Range (0,5 - 50,0)% |
Gravimetric method | PN-G-04511:1980 pkt. 2.1 | |
| 908 | Solid fuels: hard coal, lignite, coke | Moisture content in air-dried coal Range (0,5 - 20,0)% |
Gravimetric method | PN-G-04511:1980 pkt. 2.2 | |
| 909 | Solid fuels: hard coal, lignite, coke | Total moisture content (calculated) | PN-G-04511:1980 pkt. 2.3.1 | ||
| 910 | Solid fuels: hard coal, lignite, coke | Total moisture content Range (5,0 - 50,0)% |
Gravimetric method | PN-G-04511:1980 pkt. 2.3.2 i 2.3.4 | |
| 911 | Solid fuels: hard coal, lignite, coke | Moisture content in the analytical sample Range (0,1 - 16,0)% |
Gravimetric method | PN-G-04511:1980 pkt. 2.4 | |
| 912 | Solid fuels: hard coal, lignite, coke | Ash content at 815 oC Range (2,0 - 35,0)% |
Gravimetric method | PN-ISO 1171:2002 | |
| 913 | Solid fuels: hard coal, lignite, coke | Volatile matter content at 850oC Range (1,00 - 35,00)% |
Gravimetric method | PN-G-04516:1998 | |
| 914 | Solid fuels: hard coal, lignite, coke | Mercury (Hg) content Range (0,030 - 0,400) mg/kg |
Atomic absorption spectrometry with amalgamation technique | PB-LL-10 wyd. 3 z dnia 29.11.2019 r | |
| 915 | Solid fuels: hard coal, lignite, coke | Total phosphorus content Range (0,010 - 0,100)% |
Spectrophotometric method | PB-LL-15 wyd.2 z dnia 04.09.2017 r. | |
| 916 | Solid fuels: hard coal, lignite, coke | Chlorine content Range (0,03 - 0,30)% |
Ion chromatography (IC) | PB-LL-25 wyd.1 z dnia 04.09.2017 r. | |
| 917 | Solid fuels: hard coal, lignite, coke | Total carbon TC content Range (50,0 - 82,0)% |
High-temperature combustion with TCD detection | PB-LL-28 wyd. 1 z 29.01.2018 r. | |
| 918 | Solid fuels: hard coal, lignite, coke | Hydrogen content Range (2,40 - 7,00)% |
High-temperature combustion with TCD detection | PB-LL-28 wyd. 1 z 29.01.2018 r. | |
| 919 | Solid fuels: hard coal, lignite, coke | Sulfur content Range (0,15 - 3,00) % |
High-temperature combustion with TCD detection | PB-LL-28 wyd. 1 z 29.01.2018 r. | |
| 920 | Solid fuels: hard coal, lignite, coke | Nitrogen content Range (0,30 - 1,50)% |
High-temperature combustion with TCD detection | PN-G-04571:1998 | |
| 921 | Solid fuels: hard coal, lignite, coke | Gross calorific value Range (19 000 - 30 000) J/g Metoda calorimetric |
PN-ISO 1928:2020-05 | ||
| 922 | Solid fuels: hard coal, lignite, coke | Net calorific value (calculated) | PN-ISO 1928:2020-05 | ||
| 923 | Liquid fuel: diesel fuel, heavy fuel oil, mazut | Gross calorific value Range (35 000 - 46 000) J/g |
Calorimetric method | PN-C-04062:2018-05 | |
| 924 | Liquid fuel: diesel fuel, heavy fuel oil, mazut | Net calorific value (calculated) | PN-C-04062:2018-05 | ||
| 925 | Liquid fuels: - diesel fuel - liquid biofuels – fatty acid methyl esters | Content of bio-based products using the C14 carbon isotope method Range (3 - 100)% |
Liquid scintillation method | PB-LL-29 wydanie 3 z 26.05.2025r. | |
| 926 | Liquid fuels: - liquid biofuels – diesel fuel with FAME | Content of bio-based products using the C14 carbon isotope method Range (3 - 30)% |
Liquid scintillation method | PB-LL-29 wydanie 3 z 26.05.2025r. | |
| 927 | Raw materials, construction materials | Element content Antimony (0,25 - 4500) mg/kg Arsenic (0,25 - 2500) mg/kg Barium (0,25 - 2500) mg/kg Beryllium (0,25 - 3500) mg/kg Chromium (0,25 - 2500) mg/kg Zinc (0,25 - 5000) mg/kg Cadmium (0,10 - 2500) mg/kg Cobalt (0,10 - 2500) mg/kg Manganese (0,25 - 2500) mg/kg Copper (0,25 - 3000) mg/kg Molybdenum (0,20 - 2500) mg/kg Nickel (0,25 - 2500) mg/kg Lead (0,25 - 2500) mg/kg Selenium (0,25 - 4500) mg/kg Thallium (0,06 - 2500) mg/kg Vanadium (0,25 - 3500) mg/kg |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN ISO 17294-2:2024-04 | PN-EN 13657:2006 | |
| 928 | Raw materials, construction materials | Mercury (Hg) content Range (0,005 - 100,0) mg/kg |
Atomic absorption spectrometry with amalgamation technique | PB-LL-10 wyd. 3 z 29.11.2019 r. | |
| 929 | Soil | Dry matter content Range (0,5 - 99,5)% |
Gravimetric method | PN-ISO 11465:1999 | |
| 930 | Soil | Water content (calculated) | PN-ISO 11465:1999 | ||
| 931 | Soil | Loss on ignition of dry matter Range (0,5 - 99,5)% |
Gravimetric method | PN-EN 15935:2022-01 | |
| 932 | Soil | Element content Antimony (0,25 - 2500) mg/kg Arsenic (0,25 - 2500) mg/kg Barium (0,25 - 3500) mg/kg Beryllium (0,25 - 3500) mg/kg Chromium (0,25 - 2500) mg/kg Tin (0,25 - 3500) mg/kg Zinc (0,25 - 3500) mg/kg Cadmium (0,10 - 2500) mg/kg Cobalt (0,25 - 2500) mg/kg Manganese (0,25 - 2500) mg/kg Copper (0,25 - 2500) mg/kg Molybdenum (0,25 - 2500) mg/kg Nickel (0,25 - 2500) mg/kg Lead (0,25 - 2500) mg/kg Selenium (0,25 - 2500) mg/kg Thallium (0,07 - 2500) mg/kg Vanadium (0,25 - 2500) mg/kg |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN ISO 17294-2:2024-04 | PN-ISO 11466:2002 | |
| 933 | Soil | Mercury (Hg) content Range (0,05 - 30,0) mg/kg |
Atomic absorption spectrometry with amalgamation technique | PB-LL-10 wyd. 3 z 29.11.2019 r. | |
| 934 | Sewage sludge | Dry residue and water content Range (0,5 - 99,5)% |
Gravimetric method | PN-EN 15934:2013-02 | |
| 935 | Sewage sludge | Water content (calculated) | PN-EN 15934:2013-02 | ||
| 936 | Sewage sludge | Loss on ignition of dry matter/organic matter Range (0,5 - 99,5)% |
Gravimetric method | PN-EN 15935:2022-01 | |
| 937 | Sewage sludge | Element content Antimony (0,22 - 2500) mg/kg Arsenic (0,25 - 2500) mg/kg Barium (0,25 - 2500) mg/kg Beryllium (0,03 - 2500) mg/kg Chromium (0,25 - 2500) mg/kg Zinc (0,25 - 2600) mg/kg Cadmium (0,14 - 2500) mg/kg Cobalt (0,25 - 2500) mg/kg Manganese (0,25 - 2500) mg/kg Copper (0,25 - 2500) mg/kg Molybdenum (0,25 - 2500) mg/kg Nickel (0,25 - 2500) mg/kg Lead (0,25 - 2500) mg/kg Selenium (0,13 - 2500) mg/kg Thallium (0,03 - 2500) mg/kg Vanadium (0,25 - 2500) mg/kg |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN ISO 17294-2:2024-04 | PN-EN 13346:2002 | |
| 938 | Sewage sludge | Element content Cadmium (8,0 - 200) mg/kg Copper (50,0 - 2000) mg/kg Nickel (15,0 - 1000) mg/kg Lead (20,0 - 2000) mg/kg Zinc (15,0 - 5000) mg/kg Chromium (10,0 - 3000) mg/kg |
Flame atomic absorption spectrometry (FAAS) | PN-EN 13346:2002 | PN-ISO 8288:2002 | |
| 939 | Sewage sludge | Mercury (Hg) content Range (0,3 - 25,0) mg/kg |
Mercury cold vapour atomic absorption spectrometry (CVAAS) | PN-EN 13346:2002 | PN-EN ISO 12846:2012 | |
| 940 | Sewage sludge | Mercury (Hg) content Range (0,005 - 25,0) mg/kg |
Atomic absorption spectrometry with amalgamation technique | PB-LL-10 wyd. 3 z 29.11.2019 r. | |
| 941 | Sewage sludge | Phosphorus content Range (0,6 - 8,0)% |
Spectrophotometric method | PN-EN 13346:2002 | PN-EN ISO 6878:2006 | |
| 942 | Plastics, packaging materials | Element content Antimony (0,04 - 2500) mg/kg Arsenic (0,035 - 2500) mg/kg Barium (0,25 - 2500) mg/kg Beryllium (0,10 - 2500) mg/kg Chromium (0,07 - 2500) mg/kg Zinc (0,25 - 2500) mg/kg Cadmium (0,045 - 2500) mg/kg Cobalt (0,035 - 2500) mg/kg Manganese (0,25 - 2500) mg/kg Copper (0,25 - 2500) mg/kg Molybdenum (0,01 - 2500) mg/kg Nickel (0,10 - 2500) mg/kg Lead (0,10 - 2500) mg/kg Selenium (0,25 - 2500) mg/kg Thallium (0,10 - 2500) mg/kg Vanadium (0,025 - 2500) mg/kg |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN ISO 17294-2:2024-04 | PN-EN 13657:2006 | |
| 943 | Plastics, packaging materials | Fluorine content Range (45 - 800) mg/kg |
Ion chromatography method | PN-EN 15408:2011 | |
| 944 | Plastics, packaging materials | Mercury (Hg) content Range (0,005 - 5,0) mg/kg |
Atomic absorption spectrometry with amalgamation technique | PB-LL-10 wyd. 3 z 29.11.2019 r. | |
| 945 | Plastics, packaging materials | Loss on ignition Range (30,0 - 90,0)% |
Gravimetric method | PN-EN 15935:2022-01 | |
| 946 | Plastics, packaging materials | Content of biogenic carbon – share of renewable components by the C14 carbon isotope method Content of non-biogenic carbon- share of non-renewable components by the C14 carbon isotope method Range (5 - 100)% |
Liquid scintillation method | PN-EN ISO 21644:2021-07 | PN-EN 16640:2017+AC:2017-08 | |
| 947 | Plastics, packaging materials | Total organic carbon TOC content Range (1,0 - 90)% |
High-temperature combustion with IR detection | PN-EN 15936:2022-07 | |
| 948 | Plastics, packaging materials | Total carbon TC content Range (10 - 90)% |
High-temperature combustion method | PN-EN ISO 16948:2015-07 | PN-EN ISO 21663:2021-06 | |
| 949 | Plastics, packaging materials | Total nitrogen content Range (0,5 - 5,0)% |
High-temperature combustion method | PN-EN ISO 16948:2015-07 | |
| 950 | Fly ash, Waste code: 19 01 12; 19 01 14 | Loss on ignition Range (0,01 - 15,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Gravimetric method | PN-EN 450-1:2012 | PN-EN 197-1:2012 | PN-EN 14227-4:2013-10 | PN-EN 196-2:2013-11 | |
| 951 | Fly ash, Waste code: 19 01 12; 19 01 14 | Free calcium oxide content Range (0,01 - 10,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Titrimetric method | PN-EN 451-1:2017-06 | |
| 952 | Fly ash, Waste code: 19 01 12; 19 01 14 | Chloride content Range (0,002 - 5,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Titrimetric method | PN-EN 196-2:2013-11 | |
| 953 | Fly ash, Waste code: 19 01 12; 19 01 14 | Sulfate (SO3) content Range (0,05 - 20,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Gravimetric method | PN-EN 196-2:2013-11 | |
| 954 | Fly ash, Waste code: 19 01 12; 19 01 14 | Silicon dioxide (SiO2) content Range (0,01 - 70,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Gravimetric method | PN-EN 196-2:2013-11 | |
| 955 | Fly ash, Waste code: 19 01 12; 19 01 14 | Aluminium oxide content (Al2O3) Range (0,04 - 35,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Titrimetric method | PN-EN 196-2:2013-11 | |
| 956 | Fly ash, Waste code: 19 01 12; 19 01 14 | Iron oxide content (Fe2O3) Range (0,06 - 20,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Titrimetric method | PN-EN 196-2:2013-11 | |
| 957 | Fly ash, Waste code: 19 01 12; 19 01 14 | Calcium oxide content (CaO) Range (0,08 - 30,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Titrimetric method | PN-EN 196-2:2013-11 | |
| 958 | Fly ash, Waste code: 19 01 12; 19 01 14 | Magnesium oxide content (MgO) Range (0,06 - 20,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Titrimetric method | PN-EN 196-2:2013-11 | |
| 959 | Fly ash, Waste code: 19 01 12; 19 01 14 | Insoluble residue content (IR) Range (0,01 - 95)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Gravimetric method | PN-EN 196-2:2013-11 | |
| 960 | Fly ash, Waste code: 19 01 12; 19 01 14 | Carbon dioxide content Range (0,05 - 10,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Gravimetric method | PN-EN 196-2:2013-11 | |
| 961 | Fly ash, Waste code: 19 01 12; 19 01 14 | Sodium and potassium oxide content Na2O (0,05 - 10,0)% K2O (0,05 - 10,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Flame atomic emission spectrometry (FEAS) | PN-EN 196-2:2013-11 | |
| 962 | Fly ash, Waste code: 19 01 12; 19 01 14 | Total alkali content (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
PN-EN 196-2:2013-11 | ||
| 963 | Fly ash, Waste code: 19 01 12; 19 01 14 | Reactive calcium oxide content (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
PN-EN 197-1:2012 | ||
| 964 | Fly ash, Waste code: 19 01 12; 19 01 14 | Reactive silicon dioxide content (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
PN-EN 197-1:2012 | ||
| 965 | Fly ash, Waste code: 19 01 12; 19 01 14 | Content of soluble phosphates (calculated as P2O5) Range (0,006 - 200,0) mg/kg Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Spectrophotometric method | PN-EN 450-1:2012 Załącznik C | PN-EN ISO 6878:2006 | |
| 966 | Fly ash, Waste code: 19 01 12; 19 01 14 | Total phosphorus content (calculated as P2O5) Range (0,10 - 2,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Spectrophotometric method | PB-LL-16 wyd. 1 z 30.03.2016 r. | |
| 967 | Fly ash, Waste code: 19 01 12; 19 01 14 | Fineness Range (0,6 - 90,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Sieving method | PN-EN 14227-4:2013-10 | PN-EN 451-2:2017-06 | |
| 968 | Fly ash, Waste code: 19 01 12; 19 01 14 | Compressive strength Force range (10 - 300) kN Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
PN-EN 450-1:2012 | PN-EN 197-1:2012 | PN-EN 196-1:2016-07 | ||
| 969 | Fly ash, Waste code: 19 01 12; 19 01 14 | Activity index (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
PN-EN 450-1:2012 | ||
| 970 | Fly ash, Waste code: 19 01 12; 19 01 14 | Soundness Range (0 - 5) mm Le Chatelier Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Method: using rings | PN-EN 450-1:2012 | PN-EN 197-1:2012 | PN-EN 14227-4:2013-10 | PN-EN 196-3:2016-12 | |
| 971 | Fly ash, Waste code: 19 01 12; 19 01 14 | Particle density Range (1,50 - 3,00) Mg/m3 Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Method: using a pycnometer | PN-EN 1097-7:2023-04 | |
| 972 | Fly ash, Waste code: 19 01 12; 19 01 14 | Initial setting Range (10 - 500) min Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Method: using the Vicat apparatus | PN-EN 450-1:2012 | PN-EN 196-3:2016-12 | |
| 973 | Fly ash, Waste code: 19 01 12; 19 01 14 | Water demand Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Method: using a flow table | PN-EN 450-1:2012 Załącznik B | |
| 974 | Fly ash, Waste code: 10 01 01; 10 01 02;10 01 03; 10 01 17; 10 01 82; 19 01 12; 19 01 14 | Mercury (Hg) content Range (0,043 - 0,58) mg/kg Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Atomic absorption spectrometry with amalgamation technique | PB-LL-10 wyd. 3 z 29.11.2019 r. | |
| 975 | Waste E code: 10 01 | Loss on ignition Range (0,01 - 15,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 450-1 | PN-EN 197-1 | PN-EN 14227-4 | PN-EN 196-2 | |
| 976 | Waste E code: 10 01 | Free calcium oxide content Range (0,01 - 10,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 451-1 | |
| 977 | Waste E code: 10 01 | Chloride content Range (0,002 - 5,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 978 | Waste E code: 10 01 | Sulfate (SO3) content Range (0,05 - 20,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 979 | Waste E code: 10 01 | Silicon dioxide (SiO2) content Range (0,01 - 70,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 980 | Waste E code: 10 01 | Aluminium oxide content (Al2O3) Range (0,04 - 35,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 981 | Waste E code: 10 01 | Iron oxide content (Fe2O3) Range (0,06 - 20,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 982 | Waste E code: 10 01 | Calcium oxide content (CaO) Range (0,08 - 30,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 983 | Waste E code: 10 01 | Magnesium oxide content (MgO) Range (0,06 - 20,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Titrimetric method | PN-EN 196-2 | |
| 984 | Waste E code: 10 01 | Insoluble residue content (IR) Range (0,01 - 95)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 985 | Waste E code: 10 01 | Carbon dioxide content Range (0,05 - 10,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 196-2 | |
| 986 | Waste E code: 10 01 | Sodium and potassium oxide content Na2O (0,05 - 10,0)% K2O (0,05 - 10,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame atomic emission spectrometry (FEAS) | PN-EN 196-2 | |
| 987 | Waste E code: 10 01 | Total alkali content (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 196-2 | ||
| 988 | Waste E code: 10 01 | Reactive calcium oxide content (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 197-1 | ||
| 989 | Waste E code: 10 01 | Reactive silicon dioxide content (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 197-1 | ||
| 990 | Waste E code: 10 01 | Content of soluble phosphates (calculated as P2O5) Range (0,006 - 200,0) mg/kg Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PN-EN 450-1 Załącznik C | PN-EN ISO 6878 | |
| 991 | Waste E code: 10 01 | Total phosphorus content (calculated as P2O5) Range (0,10 - 2,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Spectrophotometric method | PB-LL-16 | |
| 992 | Waste E code: 10 01 | Fineness Range (0,6 - 90,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Sieving method | PN-EN 14227-4 | PN-EN 451-2 | |
| 993 | Waste E code: 10 01 | Compressive strength Force range (10 - 300) kN Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 450-1 | PN-EN 197-1 | PN-EN 196-1 | ||
| 994 | Waste E code: 10 01 | Activity index (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 450-1 | ||
| 995 | Waste E code: 10 01 | Soundness Range (0 - 5) mm Le Chatelier Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using rings | PN-EN 450-1 | PN-EN 197-1: | PN-EN 14227-4 | PN-EN 196-3 | |
| 996 | Waste E code: 10 01 | Particle density Range (1,50 - 3,00) Mg/m3 Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a pycnometer | PN-EN 1097-7 | |
| 997 | Waste E code: 10 01 | Initial setting Range (10 - 500) min Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using the Vicat apparatus | PN-EN 450-1 | PN-EN 196-3 | |
| 998 | Waste E code: 10 01 | Water demand Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Method: using a flow table | PN-EN 450-1 Załącznik B | |
| 999 | Silica fume | Free calcium oxide content Range (0,01 - 10,0)% |
Titrimetric method | PN-EN 451-1:2017-06 | |
| 1000 | Silica fume | Silicon dioxide (SiO2) content Range (0,01 - 99,0)% |
Gravimetric method | PN-EN 196-2:2013-11 | |
| 1001 | Silica fume | Sulfate (SO3) content Range (0,05 - 20,0)% |
Gravimetric method | PN-EN 196-2:2013-11 | |
| 1002 | Silica fume | Chloride content (Cl-) Range (0,002 - 5,0)% |
Titrimetric method | PN-EN 196-2:2013-11 | |
| 1003 | Silica fume | Sodium and potassium oxide content, Na2O (0,05 - 5,0)%, K2O (0,05 - 5,0)% | Flame atomic emission spectrometry (FEAS) | PN-EN 196-2:2013-11 | |
| 1004 | Silica fume | Total alkali content (calculated) | PN-EN 196-2:2013-11 | ||
| 1005 | Silica fume | Loss on ignition Range (0,01 - 30,0)% |
Gravimetric method | PN-EN 13263-1+A1:2010 | PN-EN 196-2:2013-11 | |
| 1006 | Silica fume | Compressive strength Force range (10 - 300) kN |
PN-EN 13263-1+A1:2010 | PN-EN 196-1:2016-07 | ||
| 1007 | Silica fume | Activity index (calculated) | PN-EN 13263-1+A1:2010 | ||
| 1008 | Silica fume | Dry matter content in suspension Range (0,01 - 90,0)% |
Gravimetric method | PN-EN 13263-1+A1:2010 | |
| 1009 | Cement | Flexural strength Force range (1 - 15) kN |
PN-EN 196-1:2016-07 | ||
| 1010 | Cement | Compressive strength Force range (10 - 300) kN |
PN-EN 196-1:2016-07 | ||
| 1011 | Cement | Setting time: Initial setting time Range (10 - 500) min Final setting Range (10 - 2000) min |
Method: using the Vicat apparatus | PN-EN 196-3:2016-12 | |
| 1012 | Cement | Soundness Range (0 - 5) mm Le Chatelier |
Method: using rings | PN-EN 196-3:2016-12 | |
| 1013 | Cement | Loss on ignition Range (1,0 - 10,0)% |
Gravimetric method | PN-EN 196-2:2013-11 | |
| 1014 | Cement | Sulfate (SO3) content Range (0,05 - 20,0)% |
Gravimetric method | PN-EN 196-2:2013-11 | |
| 1015 | Cement | Insoluble residue content (IR) Range (0,05 - 95,0)% |
Gravimetric method | PN-EN 196-2:2013-11 | |
| 1016 | Cement | Chloride content Range (0,002 - 5,0)% |
Titrimetric method | PN-EN 196-2:2013-11 | |
| 1017 | Cement | Sodium and potassium oxide content, Na2O (0,05 - 5,0)%, K2O (0,05 - 5,0)% | Flame atomic emission spectrometry (FEAS) | PN-EN 196-2:2013-11 | |
| 1018 | Cement | Total alkali content (calculated) | PN-EN 196-2:2013-11 | ||
| 1019 | Cement | Carbon dioxide content Range (0,05 - 10,0)% |
Gravimetric method | PN-EN 196-2:2013-11 | |
| 1020 | Cement | Sulfide content Range (0,1 - 2,0)% |
Titrimetric method | PN-EN 196-2:2013-11 | |
| 1021 | Cement | Fly ash content (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
PN-B-19707:2023-05P | ||
| 1022 | Cement | Water-soluble chromium (VI) content Range (0,000001 - 0,0012)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Spectrophotometric method | PN-EN 196-10:2016-07 | |
| 1023 | Cement | Quantitative content of components: carbonate containing silicon dioxide containing blast furnace slag clinker setting time regulator (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
CEN TR 196-4:2007 | ||
| 1024 | Cement | Mercury (Hg) content Range (0,05 - 0,17) mg/kg Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Atomic absorption spectrometry with amalgamation technique | PB-LL-10 wyd. 3 z 29.11.2019 r. | |
| 1025 | Building materials and raw materials, Waste code: 10 01 01; 10 01 02; 10 01 80 | Radionuclide activity concentration Radionuclide activity concentration 40K Range (40 - 2000) Bq/kg Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Gamma-ray spectrometry | Poradnik ITB Nr 455/2010 IL.1_1.10.03.21 | |
| 1026 | Building materials and raw materials, Waste code: 10 01 01; 10 01 02; 10 01 80 | Radionuclide activity concentration Radionuclide activity concentration 226Ra Range (3 - 1000) Bq/kg Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Gamma-ray spectrometry | Poradnik ITB Nr 455/2010 IL.1_1.10.03.21 | |
| 1027 | Building materials and raw materials, Waste code: 10 01 01; 10 01 02; 10 01 80 | Radionuclide activity concentration Radionuclide activity concentration 208Tl Range (3 - 1000) Bq/kg Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Gamma-ray spectrometry | Poradnik ITB Nr 455/2010 IL.1_1.10.03.21 | |
| 1028 | Building materials and raw materials, Waste code: 10 01 01; 10 01 02; 10 01 80 | Radionuclide activity concentration Radionuclide activity concentration 232Th (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Poradnik ITB Nr 455/2010 IL.1_1.10.03.21 | ||
| 1029 | Building materials and raw materials, Waste code: 10 01 01; 10 01 02; 10 01 80 | Activity concentration indices, I (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Poradnik ITB Nr 455/2010 IL.1_1.10.03.21 | ||
| 1030 | Gypsum | Mercury (Hg) content Range (0,21 - 15,3) mg/kg Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. |
Atomic absorption spectrometry with amalgamation technique | PB-LL-10 wyd. 3 z 29.11.2019 r. | |
| 1031 | Waste E, Code: 02 02; 02 03; 02 04; 02 05; 02 06; 02 07; 03 01; 03 03; 04 02; 15 01; 17 02; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 | Sampling for physical and chemical testing Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PB-LL-22 | ||
| 1032 | Waste E code: 02 01; 02 02; 02 03; 02 04; 02 05; 02 06; 02 07; 03 01; 03 03; 04 02; 07 02; 15 01; 16 01; 17 02; 19 01; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 | Biodegradable fraction content – mass fraction of biomass by the C14 carbon isotope method Non-biodegradable fraction content – mass fraction of non-biomass by the C14 carbon isotope method Range (25 - 100)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Liquid scintillation method | PN-EN ISO 21644 | |
| 1033 | Waste E code: 02 02; 02 03; 02 04; 02 05; 02 06; 02 07; 03 01; 03 03; 04 02; 15 01; 16 03; 17 02; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 | Biomass fraction content – mass fraction by the selective dissolution method Range (20,0 - 100)% Content of the non-biomass fraction – mass fraction by the selective dissolution method Range (0,1 - 65,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN ISO 21644 | |
| 1034 | Waste E, Code: 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02; 17 05; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 | Total organic carbon TOC content Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with IR detection | PN-EN 15936 | |
| 1035 | Waste E, Code: 07 02; 07 05; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02; 17 05; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 | Total carbon TC content Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with TCD detection | PN-EN ISO 16948 | PN-EN ISO 21663 | |
| 1036 | Waste E, Code: 07 02; 07 05; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02; 17 05; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 | Hydrogen content Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with TCD detection | PN-EN ISO 16948 | PN-EN ISO 21663 | |
| 1037 | Waste E, Code: 07 02; 07 05; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02; 17 05; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 | Sulfur content Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with TCD detection | PN-EN ISO 16994 | PN-EN 15408 | |
| 1038 | Waste E, Code: 07 02; 07 05; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02; 17 05; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 | Nitrogen content Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with TCD detection | PN-EN ISO 21663 | |
| 1039 | Waste E, Code: 07 02; 07 05; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02; 17 05; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 | Gross calorific value Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Calorimetric method | PN-EN ISO 21654 | |
| 1040 | Waste E, Code: 07 02; 07 05; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02; 17 05; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 | Net calorific value (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN ISO 21654 | ||
| 1041 | Waste E, Code: 02 02; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02; 17 05; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 | Element content Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN 13657 | PN-EN ISO 17294-2 | |
| 1042 | Waste E, Code: 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03; | Loss on ignition (LOI) Range (1,0 - 99,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 1593 | |
| 1043 | Waste E, Code: 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03; | Dry matter Range (1,0 - 99,0)% Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 15934 | |
| 1044 | Waste E, Code: 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03; | Water content (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN 15934 | ||
| 1045 | Waste E, Code: 02 02; 02 03; 02 04; 02 05; 02 06; 02 07; 03 01; 03 03; 04 02; 15 01; 16 03; 17 02; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 | Total moisture content Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | CEN/TS 15414-1 | |
| 1046 | Waste E, Code: 02 02; 02 03; 02 04; 02 05; 02 06; 02 07; 03 01; 03 03; 04 02; 15 01; 16 03; 17 02; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 | Moisture content in the analytical sample Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN ISO 21660-3 | |
| 1047 | Waste E, Code: 02 02; 02 03; 02 04; 02 05; 02 06; 02 07; 03 01; 03 03; 04 02; 15 01; 16 03; 17 02; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 | Ash content Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN ISO 21656 | |
| 1048 | Waste E, Code: 02 02; 02 03; 02 04; 02 05; 02 06; 02 07; 03 01; 03 03; 04 02; 15 01; 16 03; 17 02; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03 | Chlorine content Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Ion chromatography method | PN-EN 15408 | |
| 1049 | Waste E, Code: 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 16 01; 17 01; 17 05; 19 01; 19 02; 19 03; | Total moisture content Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | CEN/TS 15414-1 | |
| 1050 | Waste E, Code: 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 16 01; 17 01; 17 05; 19 01; 19 02; 19 03; | Moisture content in the analytical sample Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN ISO 21660-3 | |
| 1051 | Waste E, Code: 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 12; 10 13; 16 01; 17 01; 17 05; 19 01; 19 02; 19 03; | Ash content Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN ISO 21656 | |
| 1052 | Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Bromide concentration Range (0,1 - 400) mg/l Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Ion chromatography (IC) | PN-EN ISO 10304-1 | PN-EN 12457-4 | |
| 1053 | Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Chloride concentration Range (0,5 - 2000) mg/l Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Ion chromatography (IC) | PN-EN ISO 10304-1 | PN-EN 12457-4 | |
| 1054 | Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Fluoride concentration Range (0,05 - 200) mg/l Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Ion chromatography (IC) | PN-EN ISO 10304-1 | PN-EN 12457-4 | |
| 1055 | Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Nitrite concentration Range (0,03 - 120) mg/l Nitrite nitrogen concentration (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Ion chromatography (IC) | PN-EN ISO 10304-1 | PN-EN 12457-4 | |
| 1056 | Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Nitrate concentration Range (0,2 - 800) mg/l Nitrate nitrogen concentration (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Ion chromatography (IC) | PN-EN ISO 10304-1 | PN-EN 12457-4 | |
| 1057 | Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Phosphate concentration Range (0,13 - 500) mg/l Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Ion chromatography (IC) | PN-EN ISO 10304-1 | PN-EN 12457-4 | |
| 1058 | Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Sulfate concentration Range (0,5 - 2000) mg/l Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Ion chromatography (IC) | PN-EN ISO 10304-1 | PN-EN 12457-4 | |
| 1059 | Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Dissolved organic carbon DOC concentration Range (1,00 - 1000) mg/l Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with IR detection | PN-EN 1484 | PN-EN 12457-4 | |
| 1060 | Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Total dissolved solids (TDS) concentration and content Range (10,0 - 50000) mg/l Range (100 - 500000) mg/kg Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 15216 | PN-EN 12457-4 | |
| 1061 | Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | pH Range 2,0 - 12,0 Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Potentiometric method | PN-EN ISO 10523 | PN-EN 12457-4 | |
| 1062 | Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Electrical conductivity Range (80,0 - 90 000) μS/cm Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Conductometric method | PN-EN 27888 | PN-EN 12457-4 | |
| 1063 | Waste E (water extract), Code: 01 01; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Ammonium ion concentration Range (0,05 - 200) mg/l Ammonium nitrogen concentration (calculated) Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Ion chromatography (IC) | PN-EN ISO 14911 | PN-EN 12457-4 | |
| 1064 | Waste E (water extract), Code: 01 01; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Calcium concentration Range (1,0 - 4000) mg/l Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Ion chromatography (IC) | PN-EN ISO 14911 | PN-EN 12457-4 | |
| 1065 | Waste E (water extract), Code: 01 01; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Magnesium concentration Range (1,0 - 4000) mg/l Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Ion chromatography (IC) | PN-EN ISO 14911 | PN-EN 12457-4 | |
| 1066 | Waste E (water extract), Code: 01 01; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Sodium concentration Range (0,5 - 2000) mg/l Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Ion chromatography (IC) | PN-EN ISO 14911 | PN-EN 12457-4 | |
| 1067 | Waste E (water extract), Code: 01 01; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Potassium concentration Range (0,5 - 2000) mg/l Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Ion chromatography (IC) | PN-EN ISO 14911 | PN-EN 12457-4 | |
| 1068 | Waste E (water extract), Code: 01 01; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Lithium concentration Range (0,05 - 200) mg/l Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Ion chromatography (IC) | PN-EN ISO 14911 | PN-EN 12457-4 | |
| 1069 | Waste E (water extract), Code: 01 01; 02 03; 07 02; 10 01; 10 02; 10 03; 10 05; 10 06; 10 07; 10 08; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 05; 17 06; 17 09; 19 01; 19 02; 19 03; 19 05; 19 06; 19 08; 19 12; 20 01; 20 02; 20 03, Ashes E (water extract) | Element concentration and content Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN ISO 17294-2 | PN-EN 12457-4 | |
| 1070 | Waste E (water extract), Code: 10 01; 10 02; 10 03; 10 04; 10 05; 10 06; 10 11; 10 12; 10 13; 15 01; 16 01; 17 01; 17 02, Ashes1) (water extract) | Metal concentrations Na (0,1 - 500, 0) mg/l K (0,1 - 500, 0) mg/l Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Flame atomic emission spectrometry (FEAS) | PN-ISO 9964- | PN-EN 12457-4 | |
| 1071 | Waste E (water extract), Code: 01 01; 02 03; 10 01; 10 02; 10 03; 10 04; 10 05; 10 06; 10 09; 10 11; 10 12; 10 13; 15 01; 16 01; 16 81; 17 01; 17 02; 17 03; 17 06; 17 09; 19 05; 19 08; 19 12; 20 03, Ashes E (water extract) | Mercury (Hg) concentration Regulated area: waste codes according to the Regulation of the Minister of Climate on the waste catalogue. E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Atomic absorption spectrometry with amalgamation technique | PB-LL-20 | PN-EN 12457-4 | |
| 1072 | Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) | Total organic carbon TOC content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with IR detection | PN-EN 15936 | |
| 1073 | Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) | Total carbon TC content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with TCD detection | PN-EN ISO 16948 | PN-EN ISO 21663 | |
| 1074 | Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) | Hydrogen content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with TCD detection | PN-EN ISO 21663 | |
| 1075 | Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) | Sulfur content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with TCD detection | PN-EN ISO 16994 | PN-EN 15408 | |
| 1076 | Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) | Nitrogen content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
High-temperature combustion with TCD detection | PN-EN ISO 21663 | |
| 1077 | Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) | Chlorine content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Ion chromatography (IC) | PN-EN 15408 | |
| 1078 | Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) | Gross calorific value Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Calorimetric method | PN-EN ISO 21654 | |
| 1079 | Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) | Net calorific value (calculated) Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
PN-EN ISO 21654 | ||
| 1080 | Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) | Dry matter Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN 15934:2013-02 | |
| 1081 | Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) | Moisture content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN ISO 18134-1 | PN-EN ISO 18134-1 | PN-EN ISO 18134-2 | |
| 1082 | Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) | Moisture content in the analytical sample Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN ISO 21660-3 | |
| 1083 | Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) | Ash content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Gravimetric method | PN-EN ISO 21656 | |
| 1084 | Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) | Mercury (Hg) content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Atomic absorption spectrometry with amalgamation technique | PB-LL-10 | |
| 1085 | Solid fuels: E, Secondary fuels – alternative fuels; solid recovered fuels (SRF) | Element content Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN 13657 | PN-EN ISO 17294-2 | |
| Test methods | |||||
| 1086 | Ceramic slabs and tiles | Commission Decision number 98/437/WE Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope. |
EN 14411:2016 | ||
| 1087 | Lintels excluding steel lintels | Commission Decision number 97/740/EC Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope. |
EN 845-2:2013+A1:2016 | ||
| 1088 | Drainage channels | Commission Decision number 97/464/EC Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope. |
EN 1433:2002 | EN 1433:2002/A1:2005 | ||
| 1089 | Flat glass and profiled glass panes | Commission Decision number 2000/245/EC Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope. |
EN 572-9:2004 | EN 12150-2:2004 | EN 14449:2005+AC:2005 | EN 1863-2:2004 | EN 14179-2:2005 | ||
| 1090 | Insulating glass units | Commission Decision number 2000/245/EC Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope. |
EN 1279-5:2005+A2:2010 | EN 1279-5:2018 | ||
| 1091 | Cementitious tile adhesives | Commission Decision number 1999/470/EC Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope. |
EN 12004:2007+A1:2012 | EN 12004-1:2017 | ||
| 1092 | Liquid-applied water impermeable products for use beneath ceramic tiling bonded with adhesives | Commission Decision number 99/90/EC Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope. |
EN 14891:2017 | ||
| 1093 | Membranes | Commission Decision number 99/90/EC Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope. |
EN 15814:2011+A1:2012 | ||
| 1094 | Damp-proof insulating layers | Commission Decision number 99/90/EC Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope. |
EN 14967:2006 | ||
| 1095 | Gypsum products | Commission Decision number 95/467/EC Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope. |
EN 13279-1 :2008 | EN 12860:2001 + AC :2002 | EN 13963:2005 + AC :2006 | EN 14496:2005 | ||
| 1096 | Products for finishing internal; external walls and ceilings | Commission Decision number 98/437/EC Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope. |
EN 13245-2:2008 | ||
| 1097 | Floor coverings | Commission Decision number 98/808/EC Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope. |
EN 13813:2002 | EN 13454-1:2004 | ||
| 1098 | Products related to concrete; mortar and grout | Commission Decision number 99/469/EC Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope. |
EN 1504-2:2004 | EN 1504-3:2005 | EN 1504-4:2004 | EN 1504-6:2006 | ||
| 1099 | Masonry products and related products | Commission Decision number 97/740/EC Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope. |
EN 15824:2009 | EN 15824:2017 | ||
| 1100 | Thermal insulation products | Commission Decision number 99/91/EC Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE (System 3) Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011; as amended) Commission decision number Product(s) Harmonised technical specifications The current „List of subcontractors” is available on request at the accredited body. The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 2; subpoint 3 of Regulation No 305/2011) in the above scope. |
EN 13162:2012 +A1:2015 | EN 13163:2012 +A1:2015 | EN 13164:2012 +A1:2015 | EN 13165:2012 +A2:2016 | EN 13166:2012 +A2:2016 | EN 13167:2012 +A1:2015 | EN 13168:2012 +A1:2015 | EN 13169:2012 +A1:2015 | EN 13170:2012 +A1:2015 | EN 13171:2012 +A1:2015 | ||
| 1101 | Reaction to fire Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011, as amended) Essential characteristics Technical specification The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 3 of Regulation No 305/2011) in the above scope. |
EN ISO 1182 | EN ISO 11925-2 | EN 13823 | EN 1716 | EN ISO 9239-1 | |||
| 1102 | Fire resistance Regulated area: Type of activity: ASSESSMENT OF PERFORMANCE Reference document: Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ EU L 88 of 4.4.2011, as amended) Essential characteristics Technical specification The laboratory meets the requirements set out in Regulation No 305/2011 of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V; point 3 of Regulation No 305/2011) in the above scope. |
PN-EN 1364-1 | PN-EN 1365-1 | PN-EN 1634-1 | |||
Reference standards (611)
ASTM C 114
ASTM C 1293
ASTM C1260
Annex B EN-ISO 21887:2019
BN-62/6731-03
BN-80/6811-01
BN-85/7011-23
CEN TR 196-4
CEN TR 196-4:2007
CEN/TS 15414-1
CEN/TS 15414-1:2010
DIN 5033:1992 cz.3
DIN EN 16165:2023-02 Annex A, B, NB
EN 12004-1:2017
EN 12004-2
EN 12004:2007+A1:2012
EN 12150-2:2004
EN 1279-5:2005+A2:2010
EN 1279-5:2018
EN 12860:2001 + AC :2002
EN 13162:2012 +A1:2015
EN 13163:2012 +A1:2015
EN 13164:2012 +A1:2015
EN 13165:2012 +A2:2016
EN 13166:2012 +A2:2016
EN 13167:2012 +A1:2015
EN 13168:2012 +A1:2015
EN 13169:2012 +A1:2015
EN 13170:2012 +A1:2015
EN 13171:2012 +A1:2015
EN 13245-2:2008
EN 13279-1 :2008
EN 13454-1:2004
EN 13813:2002
EN 13823
EN 13963:2005 + AC :2006
EN 14179-2:2005
EN 1433:2002
EN 1433:2002/A1:2005
EN 14411:2016
EN 14449:2005+AC:2005
EN 14496:2005
EN 14891:2017
EN 14967:2006
EN 1504-2:2004
EN 1504-3:2005
EN 1504-4:2004
EN 1504-6:2006
EN 15814:2011+A1:2012
EN 15824:2009
EN 15824:2017
EN 16165:2021-10 Annex A
EN 16165:2021-10 Annex B
EN 1716
EN 1863-2:2004
EN 572-9:2004
EN 845-2:2013+A1:2016
EN ISO 1182
EN ISO 11925-2
EN ISO 9239-1
ETAG 004
ETAG 004 Europejskie Dokumenty Oceny
Europejskie Dokumenty Oceny
I/LC-21
ISO 15713:2006
ISO 21877:2017
ISO 22262-1:2012
ISO 29581-2
ISO 4316
ISO 9050 p. 3.5.3
ISO 9050 p. 3.6
ISO 9286:2021 pkt. 4.7
PB-10/BC
PB-2/BC
PB-3/BC
PB-4/BC
PB-8/BC
PB-BF-07
PB-BF-16
PB-BF-17
PB-LL-10
PB-LL-10 wyd. 3 z 29.11.2019 r.
PB-LL-10 wyd. 3 z dnia 29.11.2019 r
PB-LL-15 wyd.2 z dnia 04.09.2017 r.
PB-LL-16
PB-LL-16 wyd. 1 z 30.03.2016 r.
PB-LL-2 wyd. 1 z 15.03.2016 r.
PB-LL-20
PB-LL-20 wyd. 1 z 07.03.2016 r.
PB-LL-22
PB-LL-25 wyd.1 z dnia 04.09.2017 r.
PB-LL-28 wyd. 1 z 29.01.2018 r.
PB-LL-29 wydanie 3 z 26.05.2025r.
PB-LL-4 wyd. 1 z 30.03.2016 r.
PB-LL-5 wyd. 1 z 30.03.2016 r.
PB-LL-6 wyd. 1 z 15.03.2016 r.
PB/LC-10
PB/LC-12
PB/LC-15
PB/LC-15 VGB-M 701 e
PB/LC-17
PB/LC-19
PB/LC-22
PB/LC-26
PB/LC-27
PB/LC-28
PB/LC-5
PB/LC-5 PB/LC-6
PB/LC-6
PB/LC-9
PB/LP-15
PB/LP-20
PB/LP-23
PB/LP-25
PB/LP-26
PBA 43 wyd. 1 z dn. 27.07.2016
PBC-4-1/wyd. 6 z dnia 18.01.2010 r.
PBS-1 wyd. 1 z dnia 1.03.2014
PBT-7-1/wyd. 7 z dnia 26.05.2010 r.
PN ISO 2591-1
PN- ISO 589 Metoda A1 i A2
PN-88/B-06250
PN-88/B-06250 p. 6.5.1
PN-92/H-04185
PN-A-13004:1997 p. 3.6.
PN-B-02867 BS 8414
PN-B-04500:1985
PN-B-04500:1985 p.3.5
PN-B-06250:1988
PN-B-06250:1988 p. 6.5
PN-B-06265 Załącznik N
PN-B-10027:1993
PN-B-12012:2022-07
PN-B-13059:1985
PN-B-13083:1997
PN-B-13113:1986
PN-B-13153:1981
PN-B-13160:1985
PN-B-19306:2004
PN-B-19307:2004
PN-B-19707
PN-B-19707 Załącznik A
PN-B-19707 Załącznik B
PN-B-19707 Załącznik C
PN-B-19707:2023-05P
PN-C-04062:2018-05
PN-C-04604-08:1977
PN-EN 10080:2007 pkt. 9.3
PN-EN 1015-1
PN-EN 1015-10
PN-EN 1015-11
PN-EN 1015-12
PN-EN 1015-17
PN-EN 1015-18
PN-EN 1015-19
PN-EN 1015-21
PN-EN 1015-3
PN-EN 1015-4
PN-EN 1015-6
PN-EN 1015-7
PN-EN 1015-9
PN-EN 101:1994
PN-EN 1052-3:2004
PN-EN 1052-3:2004/A1:2009
PN-EN 1052-5
PN-EN 1062-3
PN-EN 1094-4:1998
PN-EN 1094-6:2001
PN-EN 1097-1
PN-EN 1097-2
PN-EN 1097-3
PN-EN 1097-5
PN-EN 1097-6 p.8, 9
PN-EN 1097-7
PN-EN 1097-7:2023-04
PN-EN 1097-8
PN-EN 1183:2000
PN-EN 12002:2010
PN-EN 12003:2010
PN-EN 12086
PN-EN 12087 „N”
PN-EN 12089
PN-EN 12150-1
PN-EN 12150-1 „N”
PN-EN 1217:2000
PN-EN 12190
PN-EN 12350-1
PN-EN 12350-2
PN-EN 12350-5
PN-EN 12350-7
PN-EN 12390-3
PN-EN 12390-3:2019-07
PN-EN 12390-5:2019-08
PN-EN 12390-7
PN-EN 12390-8
PN-EN 12390-8:2019-08
PN-EN 12457-4
PN-EN 12504-1:2019-08
PN-EN 12600 „N”
PN-EN 12619: 2013-05
PN-EN 12619:2013-05
PN-EN 12664 „N”
PN-EN 12667 „N”
PN-EN 12706
PN-EN 1279-2
PN-EN 1279-3
PN-EN 1279-4
PN-EN 1279-6 Zał. B p. B.4
PN-EN 12860
PN-EN 12875-1:2008
PN-EN 12875-2:2006
PN-EN 1288-3 „N”
PN-EN 12898
PN-EN 12939 „N”
PN-EN 13057
PN-EN 1308:2008
PN-EN 13137:2004
PN-EN 13211+AC:2006
PN-EN 1324:2008
PN-EN 13263-1
PN-EN 13263-1+A1:2010
PN-EN 13279-2
PN-EN 13282-1
PN-EN 13282-2
PN-EN 13310+A1:2018-11
PN-EN 13310:2005
PN-EN 13346:2002
PN-EN 1338 Załącznik D
PN-EN 1338 Załącznik F
PN-EN 1338 Załącznik I
PN-EN 1338:2005 załącznik D
PN-EN 1338:2005 załącznik E
PN-EN 1338:2005 załącznik F
PN-EN 1338:2005 załącznik H
PN-EN 1339 Załącznik D
PN-EN 1339 Załącznik F
PN-EN 1339 Załącznik I
PN-EN 1340 Załącznik D
PN-EN 1340 Załącznik F
PN-EN 1340 Załącznik I
PN-EN 1340:2004 załącznik D
PN-EN 1340:2004 załącznik E
PN-EN 1340:2004 załącznik F
PN-EN 1340:2004 załącznik H
PN-EN 13454-2
PN-EN 1346:2008
PN-EN 1348:2008
PN-EN 1348:2008 „N”
PN-EN 1363-1
PN-EN 1363-1:2001
PN-EN 1363-1:2001 z wył. P.7
PN-EN 1363-1:2012
PN-EN 1363-1:2020-07
PN-EN 1363-2:2001 z wył. P.7
PN-EN 13639
PN-EN 13639 p.6
PN-EN 1364-1
PN-EN 1364-1:2001 „N”
PN-EN 1364-1:2015-08 „N”
PN-EN 1365-1
PN-EN 1365-1:2001 „N”
PN-EN 1365-1:2013-08 „N”
PN-EN 13657
PN-EN 13657:2006
PN-EN 1367-1
PN-EN 1367-4
PN-EN 1367-6
PN-EN 13687-1
PN-EN 13687-3
PN-EN 13823 „N”
PN-EN 13872
PN-EN 1388–1:2000+Ap1:2002
PN-EN 1388–2:2000
PN-EN 13892-2
PN-EN 13892-3
PN-EN 13892-8
PN-EN 13925-1:2007 z wyłączeniem pkt.7,5; 7,6; 7,7; 7,8; 7,9; 7,10; 7,11
PN-EN 13925-2:2004 z wyłączeniem pkt.4,5; 6,3; 6,6
PN-EN 13963
PN-EN 14157:2017-11
PN-EN 14179-1
PN-EN 14179-1 „N”
PN-EN 14181:2015
PN-EN 14227-4
PN-EN 14227-4:2013-10
PN-EN 1433:2005+A1:2007
PN-EN 1433:2005+A1:2007 „N”
PN-EN 14385:2005-05
PN-EN 14385:2025-05
PN-EN 14428
PN-EN 14496
PN-EN 14516+A1:2018-12 PN–EN 14527+A1:2012
PN-EN 14527+A1:2018-12
PN-EN 14528+A1:2018-11
PN-EN 14528:2009
PN-EN 14647
PN-EN 14688+A1:2018-11
PN-EN 14688+A1:2018-11 PN–EN 14516+A1:2012
PN-EN 14688:2009
PN-EN 14789:2006
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2006
PN-EN 1484
PN-EN 1484:1999
PN-EN 14891
PN-EN 14891 p. A.6.8
PN-EN 14891 p.A.6.4
PN-EN 14891 „N”
PN-EN 15058:2006
PN-EN 15152
PN-EN 15167-1
PN-EN 15167-1 Załącznik A
PN-EN 15170
PN-EN 15216
PN-EN 15216:2022-03
PN-EN 15304:2010
PN-EN 15368
PN-EN 15408
PN-EN 15408:2011
PN-EN 1542
PN-EN 15820 „N”
PN-EN 1593
PN-EN 15934
PN-EN 15934:2013-02
PN-EN 15935:2022-01
PN-EN 15936
PN-EN 15936:2022-07
PN-EN 1607
PN-EN 1609 „N”
PN-EN 1634-1
PN-EN 1634-1+A1:2009 „N”
PN-EN 1634-1+A1:2018-03 „N”
PN-EN 16640:2017+AC:2017-08
PN-EN 16703
PN-EN 1744-1
PN-EN 1744-1 p. 14.2
PN-EN 1744-6
PN-EN 1863-1
PN-EN 1863-1 „N”
PN-EN 1911:2011
PN-EN 1928 „N”
PN-EN 1948-1:2006
PN-EN 1948-4+A1:2014-03
PN-EN 196-1
PN-EN 196-10 SFS 5183
PN-EN 196-10:2016-07
PN-EN 196-1:2016-07
PN-EN 196-2
PN-EN 196-2 VGB-M 701 e
PN-EN 196-2:2013-11
PN-EN 196-3
PN-EN 196-3:2016-12
PN-EN 196-5
PN-EN 196-6
PN-EN 196-7
PN-EN 196-9
PN-EN 197-1
PN-EN 197-1:
PN-EN 197-1:2012
PN-EN 27888
PN-EN 27888:1999
PN-EN 31+A1:2014-07
PN-EN 33:2019-06
PN-EN 356 „N”
PN-EN 35:2014-07
PN-EN 410 „N”
PN-EN 413-1
PN-EN 413-2
PN-EN 450-1
PN-EN 450-1 Załącznik B
PN-EN 450-1 Załącznik C
PN-EN 450-1:2012
PN-EN 450-1:2012 Załącznik B
PN-EN 450-1:2012 Załącznik C
PN-EN 451-1
PN-EN 451-1:2017-06
PN-EN 451-2
PN-EN 451-2:2017-06
PN-EN 459-2
PN-EN 480-10
PN-EN 480-10:2011
PN-EN 480-12
PN-EN 480-13
PN-EN 480-2
PN-EN 480-5
PN-EN 480-8
PN-EN 673 „N”
PN-EN 674
PN-EN 680:2008
PN-EN 772-1+A1:2015-10
PN-EN 772-11:2011
PN-EN 772-13:2001
PN-EN 772-13:2001, p. 7.1, 7.2
PN-EN 772-13:2001, p. 7.1, 7.3
PN-EN 772-14:2002
PN-EN 772-15:2002
PN-EN 772-16:2011
PN-EN 772-18:2011
PN-EN 772-1:2015-10
PN-EN 772-20:2002+A1: 2005
PN-EN 772-20:2002+A1:2005
PN-EN 772-21:2011
PN-EN 772-5
PN-EN 772-5:2016-06
PN-EN 772-5:2016-06/AC:2017-08
PN-EN 772-7:2000
PN-EN 80:2002
PN-EN 822
PN-EN 823
PN-EN 824
PN-EN 825
PN-EN 826 „N”
PN-EN 846-11:2002
PN-EN 846-9:2016-06 „N”
PN-EN 872:2007+Ap1:2007
PN-EN 932-1 p. 8.2, p.8.8, p.8.9
PN-EN 932-3
PN-EN 933-1
PN-EN 933-3
PN-EN 933-4
PN-EN 933-5
PN-EN 933-8
PN-EN 933-9
PN-EN 993-10:2021-03
PN-EN 993-19:2006
PN-EN 993-1:2019-01
PN-EN 993-2:1997
PN-EN 993-2:1997/A1:2004
PN-EN 993-5:2019-01
PN-EN 993-9:1999
PN-EN 997:2018-11
PN-EN ISO 10140-1 „N”
PN-EN ISO 10140-2
PN-EN ISO 10140-4
PN-EN ISO 10140-5
PN-EN ISO 10304-1
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523
PN-EN ISO 10523:2012
PN-EN ISO 10545-11:1998
PN-EN ISO 10545-12:1999
PN-EN ISO 10545-13:2017-01
PN-EN ISO 10545-14:2015-11
PN-EN ISO 10545-15:2021-11 „N”
PN-EN ISO 10545-2:2018-12
PN-EN ISO 10545-3:1999
PN-EN ISO 10545-3:2018-05
PN-EN ISO 10545-4:2019-04
PN-EN ISO 10545-5:1999
PN-EN ISO 10545-6:2012
PN-EN ISO 10545-7:2000
PN-EN ISO 10545-8:2014-09
PN-EN ISO 10545-9:2013-12
PN-EN ISO 1158:1999
PN-EN ISO 1182 „N”
PN-EN ISO 11885:2009
PN-EN ISO 11925-2 „N”
PN-EN ISO 12543-2 i 3
PN-EN ISO 12543-4
PN-EN ISO 12543-5
PN-EN ISO 12543-6
PN-EN ISO 12572:2016-10
PN-EN ISO 12677
PN-EN ISO 12677:2011
PN-EN ISO 12846:2012
PN-EN ISO 14911
PN-EN ISO 14911:2002
PN-EN ISO 1513
PN-EN ISO 15630-2:2019-04 pkt.6
PN-EN ISO 16535
PN-EN ISO 16948
PN-EN ISO 16948:2015-07
PN-EN ISO 16968:2015-07
PN-EN ISO 16994
PN-EN ISO 1716 „N”
PN-EN ISO 17294-2
PN-EN ISO 17294-2:2016-11
PN-EN ISO 17294-2:2024-04
PN-EN ISO 18122:2023-05
PN-EN ISO 18134-1
PN-EN ISO 18134-1:2023-02
PN-EN ISO 18134-2
PN-EN ISO 18134-2:2024-10
PN-EN ISO 18134-3:2023-12
PN-EN ISO 18412:2007
PN-EN ISO 1893:2009
PN-EN ISO 1927-6:2013-06
PN-EN ISO 21068-2:2010 pkt. 6.4.5
PN-EN ISO 21587-1
PN-EN ISO 21587-2
PN-EN ISO 21644
PN-EN ISO 21644:2021-07
PN-EN ISO 21645:2021-09
PN-EN ISO 21654
PN-EN ISO 21656
PN-EN ISO 21660-3
PN-EN ISO 21663
PN-EN ISO 21663:2021-06
PN-EN ISO 22167:2021-08
PN-EN ISO 26845:2009
PN-EN ISO 2811-1 ETAG 004 Europejskie Dokumenty Oceny
PN-EN ISO 29465
PN-EN ISO 29466
PN-EN ISO 29468
PN-EN ISO 29469
PN-EN ISO 29767
PN-EN ISO 354:2005 z wyłączeniem pkt. 7.3.1.
PN-EN ISO 6878
PN-EN ISO 6878:2006
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
PN-EN ISO 7459
PN-EN ISO 7783
PN-EN ISO 787-9
PN-EN ISO 8895:2007
PN-EN ISO 9239-1 „N”
PN-EN lSO 15630-1:2019-04E pkt 10.3.1, 10.3.3, 10.3.6
PN-EN lSO 15630-1:2019-04E pkt 12
PN-EN lSO 15630-1:2019-04E pkt 5
PN-EN lSO 15630-2:2019-04E pkt 5
PN-EN lSO 15630-2:2019-04E pkt 7
PN-EN lSO 6892-1:2016 Metoda B
PN-EN lSO 6892-1:2020-05 Metoda B
PN-EN-12600 „N”
PN-EN-1288-3 „N”
PN-EN-673 „N”
PN-G-04511:1980 pkt. 2.1
PN-G-04511:1980 pkt. 2.2
PN-G-04511:1980 pkt. 2.3.1
PN-G-04511:1980 pkt. 2.3.2 i 2.3.4
PN-G-04511:1980 pkt. 2.4
PN-G-04516
PN-G-04516:1998
PN-G-04528-00:1977
PN-G-04528-02:1977
PN-G-04528-03:1977
PN-G-04528-04:1977
PN-G-04528-05:1978
PN-G-04528-06:1977
PN-G-04528-07:1977
PN-G-04528-09:1979
PN-G-04528-10
PN-G-04528-11:1986
PN-G-04528-12:1977
PN-G-04571
PN-G-04571:1998
PN-G-04584
PN-H-04156-01:1981
PN-H-04156-02:1992
PN-H-04156-03:1992
PN-H-04156-04:1981
PN-H-04156-07:1981
PN-H-04156-08:1981
PN-H-04156-09:1981
PN-H-04159-07:1983
PN-ISO 10396:2001
PN-ISO 10694
PN-ISO 11465:1999
PN-ISO 11466:2002
PN-ISO 1171
PN-ISO 1171:2002
PN-ISO 11722
PN-ISO 1928
PN-ISO 1928:2020-05
PN-ISO 21645:2021-09
PN-ISO 562:2000
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 z wył. pkt. 5.2, 6.2, 6.3
PN-ISO 5667-4:2017-10 z wył. pkt.14,15,16
PN-ISO 5667-6:2016-12 z wył. pkt. 7.5, 7.6, 8.2
PN-ISO 587 p. 7.2.3.
PN-ISO 589
PN-ISO 589 Metoda B1 i B2
PN-ISO 589:2006 Metoda A2
PN-ISO 589:2006 Metoda B2
PN-ISO 7150-1:2002
PN-ISO 719
PN-ISO 7884-1
PN-ISO 7884-2
PN-ISO 8288:2002
PN-ISO 8301 „N”
PN-ISO 8301:1998
PN-ISO 9964-
PN-ISO 9964-3/Ak:1997
PN-ISO 9964-3:1994
PN-M-34129:1987 metoda A
PN-N-01252:1965
PN-O-79711:1989
PN-Z-04030-7:1994
PN-Z-15006:1993
PN-Z-15011-1:1998
PN–ISO 719:1994
Poradnik ITB Nr 455/2010 IL.1_1.10.03.21
Poradnik ITB nr 455/2010 IL.1_1.10.03.21
Procedura badawcza GDDKiA PB/1/18
Procedura badawcza GDDKiA PB/2/18
Regulamin EKG ONZ NR 43 Zał. 3 p. 9.1
Regulamin EKG ONZ nr 43 Zał. 3 p. 1, Zał.4 p.2, Zał. 5 p. 2, Zał. 8 p. 4
Regulamin EKG ONZ nr 43 Zał. 3 p. 2.1, Zał. 5 p. 3.1, Zał. 6 p. 4.3, Zał. 7 p. 3, Zał. 11 p. 3
Regulamin EKG ONZ nr 43 Zał. 3 p. 2.2, Zał. 6 p. 4.2
Regulamin EKG ONZ nr 43 Zał. 3 p. 4, Zał. 6 p. 5.1, Zał. 7 p. 4.1, Zał. 9 p. 2
Regulamin EKG ONZ nr 43 Zał. 3 p. 5
Regulamin EKG ONZ nr 43 Zał. 3 p. 6
Regulamin EKG ONZ nr 43 Zał. 3 p. 7
Regulamin EKG ONZ nr 43 Zał. 3 p. 9.2
Regulamin EKG ONZ nr 43 Zał. 3 p. 9.3
Regulamin EKG ONZ nr 43 Zał.3 p. 9.1
Regulamin EKG ONZ nr 43 Zał.3 p.3.1, Zał. 4 p. 3, Zał. 6 p. 3, Zał. 7 p. 3, Zał. 10 p.3, Zał. 11p. 3, Zał. 12 p. 3
VGB M 701 E
ZUAT-15/V.03/2003 ZUAT-15/V.04/2003
ZUAT-15/V.03/2003 ZUAT-15/V.04/2003 ETAG 004 Europejskie Dokumenty Oceny