🇵🇱 SIEĆ BADAWCZA ŁUKASIEWICZ PL
ConstructionMaterials & polymersWater & wastewater
SIEĆ BADAWCZA ŁUKASIEWICZ is a laboratory accredited by PCA under number AB 008 (Warszawa, Poland). Its accreditation scope covers 125 test methods in the following areas: Construction, Materials & polymers, Water & wastewater. Test objects include: Thermal insulation products for buildings and thermal insulation pr…, Flexible sheets for waterproofing E, Waterproofing products E, Bitumen shingles E.
At a glance
- Accreditation number: PCA AB 008
- Methods in scope: 125
- Types of test objects: 21
- City: Warszawa, Poland
- Accreditation number
- AB 008
- Accreditation body
- PCA
- Address
- – WARSZAWSKI INSTYTUT TECHNOLOGICZNY, ul. Duchnicka 3, 01-796 Warszawa, LABORATORIUM MATERIAŁÓW BUDOWLANYCH „IZOLACJA”, al. Wojciecha Korfantego 193 A
- City
- Warszawa, Poland
What this laboratory tests (21)
- Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E — 34 methods
- Flexible sheets for waterproofing E — 27 methods
- Waterproofing products E — 23 methods
- Bitumen shingles E — 11 methods
- Thermal insulation products E — 6 methods
- Construction products, bitumen shingles, corrugated bitumen sheets, fibre-cement products E — 4 methods
- Plastic films E — 4 methods
- Building materials and products E — 2 methods
- Plastics E — 2 methods
- 97/462/WE — 1 method
- 98/436/WE — 1 method
- 98/437/WE — 1 method
- 99/90/WE — 1 method
- 99/91/WE — 1 method
- ASSESSMENT OF PERFORMANCE ON THE BASIS OF TESTING (System 3) — 1 method
- and 6 more
Accreditation scope — test methods (125)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Waterproofing products E | Adhesion of the insulation to the substrate Range: (0,1-8,0) MPa "Pull off" method | Procedura Badawcza nr 6 | ||
| 2 | Waterproofing products E | External appearance and consistency | PN-B-24620 PN-B-24000 PN-B-24004 | ||
| 3 | Waterproofing products E | External appearance | PN-B-24002 | ||
| 4 | Waterproofing products E | Coating appearance | PN-B-24000 PN-B-24004 | ||
| 5 | Waterproofing products E | Ability to dilute the emulsion with water | PN-B-24002 | ||
| 6 | Waterproofing products E | Ability to dilute the mass with water | PN-B-24000 | ||
| 7 | Waterproofing products E | Water penetration of the coating | PN-B-24002 PN-B-04615:2011 PN-B-24000 | ||
| 8 | Waterproofing products E | Flow time Flow cups - 4mm and 6mm | PN-EN ISO 2431 | ||
| 9 | Waterproofing products E | Flexibility (of bitumen mastic and asphalt compound) | PN-B-24620 | ||
| 10 | Waterproofing products E | Flexibility of the coating | PN-B-24000 PN-B-24004 | ||
| 11 | Waterproofing products E | Flow resistance of bituminous mastic | PN-B-24620 | ||
| 12 | Waterproofing products E | Flow resistance of the bituminous compound | PN-B-24620 | ||
| 13 | Waterproofing products E | Sag resistance of the coating | PN-B-24004 PN-B-24002 PN-B-24000 | ||
| 14 | Waterproofing products E | Flash point Range: up to 110°C | PN-EN ISO 2719 PN-EN ISO 1523 | ||
| 15 | Waterproofing products E | Adhesion of the coating to concrete | PN-B-24004 | ||
| 16 | Waterproofing products E | Water content Range: (1,0 - 70,0) % m/m Gravimetric (distillation) method | PN-EN ISO 9029 | ||
| 17 | Waterproofing products E | Non-emulsified bitumen content | PN-B-24002 | ||
| 18 | Waterproofing products E | Bonding capacity (of bituminous mastic) | PN-B-24620 | ||
| 19 | Waterproofing products E | Drying time of the bitumen solution | PN-B-24620 | ||
| 20 | Waterproofing products E | Resistance of the coating to 3% NaCl solution | PN-B-24004 | ||
| 21 | Waterproofing products E | Skin formation time | PN-B-24002 PN-B-24000 | ||
| 22 | Waterproofing products E | Drying capability of the mass after 2 h | PN-B-24004 | ||
| 23 | Waterproofing products E | Content of volatile and non-volatile substances Range: (1,0 - 70,0) % m/m Gravimetric method | PN-84/C-81512 Metoda: C | ||
| 24 | Flexible sheets for waterproofing E | Bending resistance at low temperature Range: down to -40 °C | PN-EN 495-5 | ||
| 25 | Flexible sheets for waterproofing E | Dimensional stability | PN-EN 1107-1 metoda A PN-EN 1107-2 | ||
| 26 | Flexible sheets for waterproofing E | Flexibility | PN-EN 1109 | ||
| 27 | Flexible sheets for waterproofing E | Resistance to sagging | PN-EN 1110 | ||
| 28 | Flexible sheets for waterproofing E | Artificial ageing by long-term exposure to elevated temperature | PN-EN 1296 | ||
| 29 | Flexible sheets for waterproofing E | Artificial ageing by long-term exposure to UV radiation, elevated temperature and water | PN-EN 1297 | ||
| 30 | Flexible sheets for waterproofing E | Resistance to artificial ageing | PN-EN 13859-1 załącznik C PN-EN 13859-2 załącznik C | ||
| 31 | Flexible sheets for waterproofing E | Resistance to the action of bitumen | PN-EN 1548 | ||
| 32 | Flexible sheets for waterproofing E | Exposure to liquid chemicals and water | PN-EN 1847 | ||
| 33 | Flexible sheets for waterproofing E | Length, width, straightness | PN-EN 1848-1 | ||
| 34 | Flexible sheets for waterproofing E | Length, width, straightness, Flatness | PN-EN 1848-2 | ||
| 35 | Flexible sheets for waterproofing E | Thickness and grammage | PN-EN 1849-1 PN-EN 1849-2 | ||
| 36 | Flexible sheets for waterproofing E | Visible defects | PN-EN 1850-1 PN-EN 1850-2 | ||
| 37 | Flexible sheets for waterproofing E | Watertightness | PN-EN 1928 „N” PN-EN 13859-1 załącznik F PN-EN 13859-2 załącznik F PN-EN 13859-1 p. 5.2.3 „N” PN-EN 13859-2 p. 5.2.3 „N” | ||
| 38 | Flexible sheets for waterproofing E | Water vapour transmission Gravimetric method | PN-EN 1931 „N” | ||
| 39 | Flexible sheets for waterproofing E | Adhesion of the granules | PN-EN 12039 | ||
| 40 | Flexible sheets for waterproofing E | Resistance to air penetration | PN-EN 12114 | ||
| 41 | Flexible sheets for waterproofing E | Tear resistance (nail) | PN-EN 12310-1 PN-EN 13859-1 załącznik B PN-EN 13859-2 załącznik B | ||
| 42 | Flexible sheets for waterproofing E | Tear strength | PN-EN 12310-2 | ||
| 43 | Flexible sheets for waterproofing E | Tensile mechanical properties Range: (2 – 10000) N Displacement: up to 1000 mm | PN-EN 12311-1 PN-EN 12311-2 PN-EN 13859-1 załącznik A PN-EN 13859-2 załącznik A | ||
| 44 | Flexible sheets for waterproofing E | Peel strength of the joints | PN-EN 12316-1 PN-EN 12316-2 | ||
| 45 | Flexible sheets for waterproofing E | Shear strength of joints | PN-EN 12317-1 PN-EN 12317-2 | ||
| 46 | Flexible sheets for waterproofing E | Impact resistance | PN-EN 12691 | ||
| 47 | Flexible sheets for waterproofing E | Resistance to static load Method: A, B | PN-EN 12730 | ||
| 48 | Flexible sheets for waterproofing E | Resistance to water seepage | PN-EN 13111 „N” | ||
| 49 | Flexible sheets for waterproofing E | Resistance of film to deformation under load | PN-EN 13984 Załącznik B PN-EN 13967 załącznik B PN-EN 14909 załącznik B | ||
| 50 | Flexible sheets for waterproofing E | Watertightness after stretching at low temperature | PN-EN 13897 | ||
| 51 | Plastic films E | Grammage and thickness | PN-EN 1849-2 | ||
| 52 | Plastic films E | Dimensional change | PN-EN ISO 11501 | ||
| 53 | Plastic films E | Strength under static tension | PN-EN ISO 527-2 | ||
| 54 | Plastic films E | Mechanical properties under static tension | PN-EN ISO 527-3 | ||
| 55 | Plastics E | Total apparent density | PN-EN ISO 845 | ||
| 56 | Plastics E | Percentage share of the volume of open and closed cells Method: 2a | PN-EN ISO 4590 | ||
| 57 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Length and width Range: (1 – 20000) mm | PN-EN 822 „N” PN-EN ISO 29465 | ||
| 58 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Thickness Range: (0,1 – 300) mm | PN-EN 823 „N” PN-EN ISO 29466 | ||
| 59 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Deviation from squareness | PN-EN 824 „N” | ||
| 60 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Deviation from flatness | PN-EN 825 „N” PN-EN ISO 29468 | ||
| 61 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Compressive strength Range: (2 – 50000) N Compressive stress Relative deformation Compressive modulus of elasticity | PN-EN 826 „N” PN-EN ISO 29469 | ||
| 62 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Total apparent density Apparent density of the core | PN-EN 1602 PN-EN ISO 29470 | ||
| 63 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Change in deviation from flatness Change in dimensions Method: A, B1, B2, C | PN-EN 1603 | ||
| 64 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Dimensional change | PN-EN 1604 | ||
| 65 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Deformation under compressive load under specified temperature conditions | PN-EN 1605 | ||
| 66 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Compressive creep | PN-EN 1606 PN-EN ISO 16534 | ||
| 67 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Tensile strength perpendicular to the faces | PN-EN 1607 | ||
| 68 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Short-term water absorption Partial immersion method Method: A, B | PN-EN 1609 PN-EN ISO 29767 „N” | ||
| 69 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Water vapour permeability Gravimetric method | PN-EN 12086 „N” | ||
| 70 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Water absorption by long-term partial immersion Water absorption by long-term total immersion Method: 1A, 1B, 2A, 2B, 2C | PN-EN 12087 PN-EN ISO 16535 „N” | ||
| 71 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Water absorption by long-term diffusion | PN-EN 12088 PN-EN ISO 16536 „N” | ||
| 72 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Flexural strength Method: B | PN-EN 12089 | ||
| 73 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Shear strength Shear modulus | PN-EN 12090 | ||
| 74 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Behaviour under point load - compressive force at the critical point - deformation at the critical point Point load at a given deformation | PN-EN 12430 | ||
| 75 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Thickness of products for the insulation of floating floors | PN-EN 12431 PN-EN ISO 29770 | ||
| 76 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Thermal resistance Range: (0,1 – 7,5) m2·K/W Thermal conductivity coefficient Thermal transmittance coefficient Thermal resistivity Thermal transmittance Heat flux density | PN-EN 12667 „N” PN-ISO 8301 PN-EN 12664 | ||
| 77 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Thermal resistance Range: (0,15 – 7,5) m2·K/W Thermal conductivity coefficient Thermal transmittance Heat flux density | PN-EN 12939 „N” | ||
| 78 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Thermal resistance Range: (0,1 – 3,75) m2·K/W Thermal resistivity Thermal conductivity Thermal transmittance | PN-ISO 8302 | ||
| 79 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Thermal conductance related to length and to area Thermal resistance related to length and to area Thermal conductivity Specific thermal resistivity Surface heat transfer coefficient of the insulation | PN-EN ISO 8497 „N” | ||
| 80 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Percentage share of the volume of open and closed cells Method: 2a | PN-EN ISO 4590 | ||
| 81 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Linear dimensions | PN-EN 12085 PN-EN ISO 29768 | ||
| 82 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Organic matter content | PN-EN 13820 | ||
| 83 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Maximum service temperature | PN-EN 14706 PN-EN ISO 18097 PN-EN 14707 PN-EN ISO 18096 | ||
| 84 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Moisture content in pressed cork | PN-EN 12105 | ||
| 85 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Dimensions, squareness and straightness of pipe insulation shells | PN-EN 13467 „N” PN-EN ISO 12628 | ||
| 86 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Water absorption of pipe insulation by short-term partial immersion | PN-EN 13472 „N” PN-EN ISO 12623 | ||
| 87 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Water vapour transmission of pipe insulation: - water vapour diffusion resistance factor - water vapour permeability - transmission coefficient Gravimetric method | PN-EN 13469 „N” PN-EN ISO 12629 | ||
| 88 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Apparent density of pipe sections | PN-EN 13470 PN-EN ISO 18098 | ||
| 89 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Chloride ion concentration in water extracts Range: from 0,5 mg/l to 25 mg/l Potentiometric titration method | PN-EN 13468 „N” PN-EN ISO 12624 | ||
| 90 | Thermal insulation products for buildings and thermal insulation products for building equipment and industrial installations E | Determination of pH in aqueous extracts, Potentiometric method | Procedura Badawcza nr 10 ”N” | ||
| 91 | Thermal insulation products E | Bulk density of aggregates | PN-EN 1097-3 | ||
| 92 | Thermal insulation products E | Water content by drying in a ventilated oven | PN-EN 1097-5 | ||
| 93 | Thermal insulation products E | Resistance to crushing Range: up to 50 kN | PN-EN 13055 Załącznik C | ||
| 94 | Thermal insulation products E | Hydrophobicity of aggregates | PN-EN 14316-1 Załącznik E | ||
| 95 | Thermal insulation products E | Pull-off strength of the bituminous membrane from expanded polystyrene boards | Procedura Badawcza nr 3 | ||
| 96 | Thermal insulation products E | Peel strength of the bituminous membrane from the surface of expanded polystyrene boards | Procedura Badawcza nr 4 | ||
| 97 | Materials used in floating floors in residential buildings E | Dynamic stiffness Excitation frequency Range: (10 – 160) Hz Force Range: (0,1 – 0,8) N Method of forced vibration of the loading plate | PN-EN 29052-1 | ||
| 98 | Materials for acoustic insulation and acoustic treatment E | Airflow resistance Range: (12500 – 2490000) Pa·s/m3 Method: A | PN-EN 29053 PN-EN ISO 9053-1 | ||
| 99 | Building materials and products E | Water vapour transport: - permeability - resistance - transmission coefficient Gravimetric method | PN-EN ISO 12572 „N” | ||
| 100 | Building materials and products E | Smouldering | PN-EN 16733 | ||
| 101 | Construction products E | Formaldehyde emission rate Range: (25 ÷ 640) µg/(m2·h) Spectrophotometric method (chamber) | Procedura Badawcza nr 1 | ||
| 102 | Construction products, bitumen shingles, corrugated bitumen sheets, fibre-cement products E | Fire growth rate index: FIGRA0,2MJ FIGRA0,4MJ Total heat release THR600sek Smoke growth rate SMOGRA Total smoke production TSP600sek Lateral flame spread LFS Production of flaming droplets and particles | PN-EN 13823+A1 „N” | ||
| 103 | Construction products, bitumen shingles, corrugated bitumen sheets, fibre-cement products E | Temperature rise Mass loss Duration of flaming | PN-EN ISO 1182 „N” | ||
| 104 | Construction products, bitumen shingles, corrugated bitumen sheets, fibre-cement products E | Gross calorific value PCS | PN-EN ISO 1716 „N” | ||
| 105 | Construction products, bitumen shingles, corrugated bitumen sheets, fibre-cement products E | Occurrence of inflammation Spread of flames Fs Inflammation of the filter paper | PN-EN ISO 11925-2 „N” | ||
| 106 | Bitumen shingles E | Height | PN-EN 544 | ||
| 107 | Bitumen shingles E | Width | |||
| 108 | Bitumen shingles E | Tensile force | PN-EN 544 PN-EN 12311-1 | ||
| 109 | Bitumen shingles E | Nail tear strength | PN-EN 544 PN-EN 12310-1 | ||
| 110 | Bitumen shingles E | Mass of bitumen | PN-EN 544 | ||
| 111 | Bitumen shingles E | Water absorption | PN-EN 544 | ||
| 112 | Bitumen shingles E | Resistance to UV radiation | PN-EN 544 PN-EN 1297 | ||
| 113 | Bitumen shingles E | Resistance to blistering | PN-EN 544 | ||
| 114 | Bitumen shingles E | Resistance to sagging at elevated temperature | PN-EN 544 PN-EN 1110 | ||
| 115 | Bitumen shingles E | Adhesion of the mineral granules | PN-EN 544 PN-EN 12039 | ||
| 116 | Bitumen shingles E | Peel resistance of metal foil | PN-EN 544 PN-EN 12311-1 | ||
| 117 | Roofs, bitumen shingles, corrugated bitumen sheets, fibre-cement products E | External fire exposure of roofs Test 1: burning brands method - extent and type of damage - flame spread - burning droplets - penetration | PKN-CEN/TS | ||
| 118 | Type of activity: | Reference document: | |||
| 119 | ASSESSMENT OF PERFORMANCE ON THE BASIS OF TESTING (System 3) | Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC | |||
| 120 | Commission decision number | Product(s) | Zharmonizowane specyfikacje techniczne | ||
| 121 | 99/91/WE | Thermal insulation products | EN 13162:2012+A1:2015 EN 13163:2012+A1:2015 EN 13164:2012+A1:2015 EN 13165:2012+A2:2015 EN 13166:2012+A2:2016 EN 13167:2012+A1:2015 EN 13168:2012+A1:2015 EN 13169:2012+A1:2015 EN 13170:2012+A1:2015 EN 13171:2012+A1:2015 EN 14063-1:2004 EN 14063-1:2004/AC:2006 EN 14064-1:2010 EN 14303:2009+A1:2013 EN 14304:2009+A1:2013 EN 14305:2009+A1:2013 EN 14306:2009+A1:2013 EN 14307:2009+A1:2013 EN 14308:2009+A1:2013 EN 14309:2009+A1:2013 EN 14313:2009+A1:2013 EN 14314:2009+A1:2013 EN 14315-1:2003 EN 14316-1:2004 EN 14317-1:2004 EN 14318-1:2013 EN 14319-1:2013 EN 14320-1:2013 EN 14933:2007 EN 14934:2007 EN 15501:2013 EN 15599-1:2010 EN 15600-1:2010 EN 15732:2012 EN 16069:2012 EN 16069:2012+A1:2015 | ||
| 122 | 99/90/WE | Membranes | EN 13707:2004+A2:2009 EN 13859-1:2010 EN 13859-2:2010 EN 13956:2012 EN 13967:2012 EN 13969:2004 EN 13969:2004/A1:2006 EN 13970:2004 EN 13970:2004/A1:2006 EN 13984:2013 EN 14909:2012 EN 14967:2006 | ||
| 123 | 98/437/WE | Finishing of interior, exterior walls and ceilings | EN 534:2006+A1:2010 EN 14509:2013 | ||
| 124 | 98/436/WE | Roofing, skylights, roof windows and accessories | EN 494:2012+A1:2015 EN 534:2006+A1:2010 EN 492:2012+A1:2015 EN 544:2011 EN 14509:2013 | ||
| 125 | 97/462/WE | Wood-based panels, unfaced and veneered or coated | EN 13986:2004+A1:2015 | ||
Reference standards (108)
EN 13162:2012+A1:2015 EN 13163:2012+A1:2015 EN 13164:2012+A1:2015 EN 13165:2012+A2:2015 EN 13166:2012+A2:2016 EN 13167:2012+A1:2015 EN 13168:2012+A1:2015 EN 13169:2012+A1:2015 EN 13170:2012+A1:2015 EN 13171:2012+A1:2015 EN 14063-1:2004 EN 14063-1:2004/AC:2006 EN 14064-1:2010 EN 14303:2009+A1:2013 EN 14304:2009+A1:2013 EN 14305:2009+A1:2013 EN 14306:2009+A1:2013 EN 14307:2009+A1:2013 EN 14308:2009+A1:2013 EN 14309:2009+A1:2013 EN 14313:2009+A1:2013 EN 14314:2009+A1:2013 EN 14315-1:2003 EN 14316-1:2004 EN 14317-1:2004 EN 14318-1:2013 EN 14319-1:2013 EN 14320-1:2013 EN 14933:2007 EN 14934:2007 EN 15501:2013 EN 15599-1:2010 EN 15600-1:2010 EN 15732:2012 EN 16069:2012 EN 16069:2012+A1:2015
EN 13707:2004+A2:2009 EN 13859-1:2010 EN 13859-2:2010 EN 13956:2012 EN 13967:2012 EN 13969:2004 EN 13969:2004/A1:2006 EN 13970:2004 EN 13970:2004/A1:2006 EN 13984:2013 EN 14909:2012 EN 14967:2006
EN 13986:2004+A1:2015
EN 494:2012+A1:2015 EN 534:2006+A1:2010 EN 492:2012+A1:2015 EN 544:2011 EN 14509:2013
EN 534:2006+A1:2010 EN 14509:2013
PKN-CEN/TS
PN-84/C-81512 Metoda: C
PN-B-24000
PN-B-24000 PN-B-24004
PN-B-24002
PN-B-24002 PN-B-04615:2011 PN-B-24000
PN-B-24002 PN-B-24000
PN-B-24004
PN-B-24004 PN-B-24002 PN-B-24000
PN-B-24620
PN-B-24620 PN-B-24000 PN-B-24004
PN-EN 1097-3
PN-EN 1097-5
PN-EN 1107-1 metoda A PN-EN 1107-2
PN-EN 1109
PN-EN 1110
PN-EN 12039
PN-EN 12085 PN-EN ISO 29768
PN-EN 12086 „N”
PN-EN 12087 PN-EN ISO 16535 „N”
PN-EN 12088 PN-EN ISO 16536 „N”
PN-EN 12089
PN-EN 12090
PN-EN 12105
PN-EN 12114
PN-EN 12310-1 PN-EN 13859-1 załącznik B PN-EN 13859-2 załącznik B
PN-EN 12310-2
PN-EN 12311-1 PN-EN 12311-2 PN-EN 13859-1 załącznik A PN-EN 13859-2 załącznik A
PN-EN 12316-1 PN-EN 12316-2
PN-EN 12317-1 PN-EN 12317-2
PN-EN 12430
PN-EN 12431 PN-EN ISO 29770
PN-EN 12667 „N” PN-ISO 8301 PN-EN 12664
PN-EN 12691
PN-EN 12730
PN-EN 12939 „N”
PN-EN 1296
PN-EN 1297
PN-EN 13055 Załącznik C
PN-EN 13111 „N”
PN-EN 13467 „N” PN-EN ISO 12628
PN-EN 13468 „N” PN-EN ISO 12624
PN-EN 13469 „N” PN-EN ISO 12629
PN-EN 13470 PN-EN ISO 18098
PN-EN 13472 „N” PN-EN ISO 12623
PN-EN 13820
PN-EN 13823+A1 „N”
PN-EN 13859-1 załącznik C PN-EN 13859-2 załącznik C
PN-EN 13897
PN-EN 13984 Załącznik B PN-EN 13967 załącznik B PN-EN 14909 załącznik B
PN-EN 14316-1 Załącznik E
PN-EN 14706 PN-EN ISO 18097 PN-EN 14707 PN-EN ISO 18096
PN-EN 1548
PN-EN 1602 PN-EN ISO 29470
PN-EN 1603
PN-EN 1604
PN-EN 1605
PN-EN 1606 PN-EN ISO 16534
PN-EN 1607
PN-EN 1609 PN-EN ISO 29767 „N”
PN-EN 16733
PN-EN 1847
PN-EN 1848-1
PN-EN 1848-2
PN-EN 1849-1 PN-EN 1849-2
PN-EN 1849-2
PN-EN 1850-1 PN-EN 1850-2
PN-EN 1928 „N” PN-EN 13859-1 załącznik F PN-EN 13859-2 załącznik F PN-EN 13859-1 p. 5.2.3 „N” PN-EN 13859-2 p. 5.2.3 „N”
PN-EN 1931 „N”
PN-EN 29052-1
PN-EN 29053 PN-EN ISO 9053-1
PN-EN 495-5
PN-EN 544
PN-EN 544 PN-EN 1110
PN-EN 544 PN-EN 12039
PN-EN 544 PN-EN 12310-1
PN-EN 544 PN-EN 12311-1
PN-EN 544 PN-EN 1297
PN-EN 822 „N” PN-EN ISO 29465
PN-EN 823 „N” PN-EN ISO 29466
PN-EN 824 „N”
PN-EN 825 „N” PN-EN ISO 29468
PN-EN 826 „N” PN-EN ISO 29469
PN-EN ISO 11501
PN-EN ISO 1182 „N”
PN-EN ISO 11925-2 „N”
PN-EN ISO 12572 „N”
PN-EN ISO 1716 „N”
PN-EN ISO 2431
PN-EN ISO 2719 PN-EN ISO 1523
PN-EN ISO 4590
PN-EN ISO 527-2
PN-EN ISO 527-3
PN-EN ISO 845
PN-EN ISO 8497 „N”
PN-EN ISO 9029
PN-ISO 8302
Procedura Badawcza nr 1
Procedura Badawcza nr 10 ”N”
Procedura Badawcza nr 3
Procedura Badawcza nr 4
Procedura Badawcza nr 6
Zharmonizowane specyfikacje techniczne