🇨🇿 MeTeKa-CZ s.r.o. PL

ČIA 2387 • Ludkovice, Czech Republic • 20 calibration items

Metrology & calibration

MeTeKa-CZ s.r.o. is a calibration laboratory accredited by ČIA under number 2387 (Ludkovice, Czech Republic). Its accreditation scope covers 20 calibration items in the following areas: Metrology & calibration. Calibrated items include: Direct-reading temperature meters, Thermoelectric sensors, Resistance temperature sensors, Controllers and indicators. Most frequently used calibration principles: Comparison with a standard resistance thermometer in a furnace, Comparison with a standard resistance thermometer in a liquid bath, Comparison with a standard resistance thermometer in an ice-water m….

At a glance

  • Accreditation number: ČIA 2387
  • Calibration items in scope: 20
  • Types of calibrated items: 10
  • Calibration principles used: 12
  • City: Ludkovice, Czech Republic
  • Valid until: 16-10-2028
Accreditation number
2387
Accreditation body
ČIA
Address
č.p. 100, 763 41 Ludkovice
City
Ludkovice, Czech Republic
Division
Laboratorium wzorcujące
Valid until
16-10-2028

What this laboratory calibrates (10)

Calibration principles (12)

Certificate information

Certificate date
07.04.2026

Accreditation scope — calibration items (20)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Deformation pressure gauges Calibration – pressure
Absolute pressure; gas — 5 kPa to 300 kPa · CMC 0,025 % + 0,2 kPa Gauge pressure; gas — -95 kPa to 200 kPa · CMC 0,025 % + 0,05 kPa Gauge pressure, absolute pressure; gas — 200 kPa to 2000 kPa · CMC 0,025 % + 0,2 kPa Gauge pressure, absolute pressure; gas — 2 MPa to 14 MPa · CMC 0,025 % + 15 kPa Gauge pressure, absolute pressure; oil — 0 MPa to 100 MPa · CMC 0,025 % + 15 kPa
CMC for the field of measured quantity: Pressure
Comparison with a standard digital pressure gauge KP 1/P
2 Pressure transducers, digital pressure gauges Calibration – pressure
Absolute pressure; gas — 5 kPa to 300 kPa · CMC 0,025 % + 0,08 kPa Gauge pressure; gas — -95 kPa to 200 kPa · CMC 0,025 % + 0,05 kPa Gauge pressure, absolute pressure; gas — 200 kPa to 2000 kPa · CMC 0,025 % + 0,25 kPa Gauge pressure, absolute pressure; gas — 2 MPa to 14 MPa · CMC 0,025 % + 16 kPa Gauge pressure, absolute pressure; oil — 0 MPa to 100 MPa · CMC 0,025 % + 16 kPa Barometric pressure; gas — 70 kPa to 120 kPa · CMC 50 Pa
CMC for the field of measured quantity: Pressure
Comparison with a standard digital pressure gauge KP 2/P, KP 3/P
3 Thermoelectric sensors Calibration – temperature
0 °C · CMC 0,4 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance thermometer in an ice-water mixture KP 1/T
4 Thermoelectric sensors Calibration – temperature
-45 °C to 30 °C · CMC 0,4 °C 300 °C to 420 °C · CMC 0,6 °C 420 °C to 600 °C · CMC 0,8 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance thermometer in a furnace KP 1/T
5 Thermoelectric sensors Calibration – temperature
30 °C to 300 °C · CMC 0,4 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance thermometer in a liquid bath KP 1/T
6 Thermoelectric sensors Calibration – temperature
600 °C to 900 °C · CMC 1,4 °C 900 °C to 1100 °C · CMC 1,7 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermoelectric thermometer in a horizontal furnace KP 1/T
7 Resistance temperature sensors Calibration – temperature
0 °C · CMC 0,07 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance thermometer in an ice-water mixture KP 2/T
8 Resistance temperature sensors Calibration – temperature
-45 °C to 30 °C · CMC 0,09 °C 300 °C to 420 °C · CMC 0,5 °C 420 °C to 660 °C · CMC 0,7 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance thermometer in a furnace KP 2/T
9 Resistance temperature sensors Calibration – temperature
30 °C to 300 °C · CMC 0,07 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance thermometer in a liquid bath KP 2/T
10 Direct-reading temperature meters Calibration – temperature
0 °C · CMC 0,07 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance thermometer in an ice-water mixture KP 4/T
11 Direct-reading temperature meters Calibration – temperature
-45 °C to 30 °C · CMC 0,09 °C 300 °C to 420 °C · CMC 0,5 °C 420 °C to 600 °C · CMC 0,7 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance thermometer in a furnace KP 4/T
12 Direct-reading temperature meters Calibration – temperature
30 °C to 300 °C · CMC 0,07 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance thermometer in a liquid bath KP 4/T
13 Direct-reading temperature meters Calibration – temperature
600 °C to 900 °C · CMC 1,4 °C 900 °C to 1100 °C · CMC 1,7 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermoelectric thermometer in a horizontal furnace KP 4/T
14 Controllers and indicators Calibration – temperature
with a type K sensor — -50 °C to 1300 °C · CMC 0,3 °C with a type S sensor — 300 °C to 1700 °C · CMC 0,6 °C with a type B sensor — 300 °C to 1800 °C · CMC 0,6 °C with a type R sensor — 300 °C to 1700 °C · CMC 0,6 °C with a type J sensor — -100 °C to 1000 °C · CMC 0,2 °C with a type N sensor — -100 °C to 1300 °C · CMC 0,2 °C
CMC for the field of measured quantity: Temperature
Simulation of thermoelectric temperature sensors by electrical voltage KP 5/T
15 Controllers and indicators Calibration – temperature
with a type Pt, Ni, Cu sensor — -200 °C to 850 °C · CMC 0,06 °C
CMC for the field of measured quantity: Temperature
Simulation of resistance temperature sensors by electrical resistance KP 5/T
16 Direct-reading thermometers as part of air-conditioning and temperature chambers Calibration – temperature
-45 °C to 0 °C · CMC 1,0 °C 0 °C to 650 °C · CMC 1,1 °C 650 °C to 900 °C · CMC 1,6 °C 900 °C to 1000 °C · CMC 1,7 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermoelectric thermometer KP 6/T
17 Non-contact thermometers Calibration – temperature
35 °C to 50 °C · CMC 1,3 °C 50 °C to 150 °C · CMC 1,7 °C 150 °C to 350 °C · CMC 2,8 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard non-contact thermometer KP 7/T
18 Hygrometers and humidity measuring chains including humidity probes and characterisation of climatic chambers Calibration – air humidity
(15 to 40) °C — 5 % RH to 10 % RH · CMC 1,6 % RH (15 to 40) °C — 10 % RH to 50 % RH · CMC 1,7 % RH (15 to 40) °C — 50 % RH to 80 % RH · CMC 1,8 % RH (15 to 40) °C — 80 % RH to 95 % RH · CMC 2,0 % RH
CMC for the field of measured quantity: Air humidity
Comparison with a standard capacitive hygrometer KP 1/V
19 Electronic and manual stopwatches Calibration – time and frequency quantities
10 s to 100000 s · CMC 0,25 s
CMC for the field of measured quantity: Time and frequency quantities
Electronically triggered comparison with a standard KP 1/F
20 Electronic and manual stopwatches Calibration – time and frequency quantities
10 s to 28 h · CMC 0,35 s
CMC for the field of measured quantity: Time and frequency quantities
Manually triggered comparison with a standard KP 1/F

Reference standards (11)

KP 1/F
KP 1/P
KP 1/T
KP 1/V
KP 2/P
KP 2/T
KP 3/P
KP 4/T
KP 5/T
KP 6/T
KP 7/T

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/2387