VENTURI Calibration Services spol. s r.o. is a calibration laboratory accredited by ČIA under number 2366 (Blatnice pod Svatým Antonínkem, Czech Republic). Its accreditation scope covers 6 calibration items in the following areas: Metrology & calibration. Calibrated items include: Flow meters, volume meters and water meters, Metering runs with flow restriction elements. Most frequently used calibration principles: Volumetric method, Gravimetric method.
At a glance
- Accreditation number: ČIA 2366
- Calibration items in scope: 6
- Types of calibrated items: 2
- Calibration principles used: 2
- City: Blatnice pod Svatým Antonínkem, Czech Republic
- Valid until: 29-01-2030
- Accreditation number
- 2366
- Accreditation body
- ČIA
- Address
- Blatnice pod Svatým Antonínkem 866, 696 71
- City
- Blatnice pod Svatým Antonínkem, Czech Republic
- Division
- VENTURI Calibration Services spol. s r.o.
- Valid until
- 29-01-2030
What this laboratory calibrates (2)
- Flow meters, volume meters and water meters — 3 calibration items
- Metering runs with flow restriction elements — 3 calibration items
Calibration principles (2)
- Volumetric method — 4 calibration items
- Gravimetric method — 2 calibration items
Certificate information
- Certificate date
- 29.01.2025
Accreditation scope — calibration items (6)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Flow meters, volume meters and water meters | Calibration – flow 20 °C to 80 °C — 1,0 m³/h to 150 m³/h · CMC 0,20 % CMC for the field of measured quantity: Flow |
Volumetric method | KP 03 | |
| 2 | Flow meters, volume meters and water meters | Calibration – flow 35 °C to 80 °C — 40 m³/h to 4245 m³/h · CMC 0,20 % CMC for the field of measured quantity: Flow |
Volumetric method | KP 01 | |
| 3 | Flow meters, volume meters and water meters | Calibration – flow 35 °C to 80 °C — 11,1 kg/s to 1166 kg/s · CMC 0,10 % CMC for the field of measured quantity: Flow |
Gravimetric method | KP 01 | |
| 4 | Metering runs with flow restriction elements | Calibration – flow 20 °C to 80 °C — 1,0 m³/h to 150 m³/h · CMC 0,21 % CMC for the field of measured quantity: Flow |
Volumetric method | KP 04 | |
| 5 | Metering runs with flow restriction elements | Calibration – flow 35 °C to 80 °C — 40 m³/h to 4245 m³/h · CMC 0,21 % CMC for the field of measured quantity: Flow |
Volumetric method | KP 02 | |
| 6 | Metering runs with flow restriction elements | Calibration – flow 35 °C to 80 °C — 11,1 kg/s to 1166 kg/s · CMC 0,14 % CMC for the field of measured quantity: Flow |
Gravimetric method | KP 02 | |
Reference standards (4)
KP 01
KP 02
KP 03
KP 04