🇨🇿 UNIMETRA, spol. s r.o. PL

ČIA 2310 • Ostrava, Czech Republic • 68 calibration items

Metrology & calibration

UNIMETRA, spol. s r.o. is a calibration laboratory accredited by ČIA under number 2310 (Ostrava, Czech Republic). Its accreditation scope covers 68 calibration items in the following areas: Metrology & calibration. Calibrated items include: Engineering and electronic levels, Line gauges, Parallel gauge blocks, Tape measures. Most frequently used calibration principles: Measurement using parallel gauge blocks, Measurement on a length gauge, Measurement by a laser interferometer.

At a glance

  • Accreditation number: ČIA 2310
  • Calibration items in scope: 68
  • Types of calibrated items: 63
  • Calibration principles used: 34
  • City: Ostrava, Czech Republic
  • Valid until: 07-01-2031
Accreditation number
2310
Accreditation body
ČIA
Address
Rohova 1506/6, 716 00 Ostrava - Radvanice
City
Ostrava, Czech Republic
Division
Dział Laboratorium wzorcujące
Valid until
07-01-2031

What this laboratory calibrates (63)

Calibration principles (34)

Certificate information

Certificate date
07.01.2026

Accreditation scope — calibration items (68)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Micrometer calliper gauges Calibration – length
0 mm to 1000 mm · CMC (9·L + 1,5) µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks PP-11.01
2 Pasameters Calibration – length
up to 200 mm — -5 mm to 5 mm · CMC (3,5·L + 0,7) µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks PP-11.01
3 Parallel gauge blocks Calibration – length
0,5 mm to 100 mm · CMC (1,5·L + 0,15) µm
CMC for the field of measured quantity: Length
Comparison with parallel gauge blocks on a comparator PP-11.02
4 Parallel gauge blocks Calibration – length
125 mm to 500 mm · CMC (2·L + 0,16) µm
CMC for the field of measured quantity: Length
Comparison with parallel gauge blocks on a length gauge PP-11.02
5 Slide gauges Calibration – length
0 mm to 1000 mm · CMC (5·L + 15) µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks PP-11.05
6 Height gauges Calibration – length
0 mm to 1000 mm · CMC (8·L + 0,7) µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks PP-11.05
7 Line gauges Calibration – length
0 mm to 1000 mm · CMC (15·L + 20) µm 1000 mm to 10000 mm · CMC (16·L + 28) µm
CMC for the field of measured quantity: Length
Comparison with a standard scale PP-11.06
8 Line gauges Calibration – length
0 mm to 10000 mm · CMC (10·L + 20) µm
CMC for the field of measured quantity: Length
Measurement by a laser interferometer PP-11.06
9 Rules of portable microscopes Calibration – length
0 mm to 20 mm · CMC 4,5 µm
CMC for the field of measured quantity: Length
Measurement on a 3D microscope PP-11.06
10 Tape measures Calibration – length
0 m to 20 m · CMC (20·L + 20) µm
CMC for the field of measured quantity: Length
Measurement by a laser interferometer PP-11.06
11 Tape measures Calibration – length
20 m to 100 m · CMC (21·L + 30) µm
CMC for the field of measured quantity: Length
Comparison with a standard scale PP-11.06
12 Tape measures - digital Calibration – length
0 m to 5 m · CMC (2·L + 120) µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks PP-11.06
13 Laser distance meters Calibration – length
0 m to 20 m · CMC 0,4 mm
CMC for the field of measured quantity: Length
Comparison with a standard scale PP-11.06
14 Inside micrometer gauges, extension rods Calibration – length
0 mm to 1000 mm · CMC (9·L + 1,5) µm 1000 mm to 3000 mm · CMC (9,5·L + 2) µm
CMC for the field of measured quantity: Length
Measurement on a length gauge PP-11.09
15 Micrometric heads Calibration – length
0 mm to 50 mm · CMC (3·L + 1,2) µm
CMC for the field of measured quantity: Length
Measurement on a length gauge PP-11.09
16 Inside micrometers Calibration – length
0 mm to 300 mm · CMC (6·L + 1,5) µm
CMC for the field of measured quantity: Length
Measurement by setting rings PP-11.09
17 Micrometer depth gauges Calibration – length
0 mm to 300 mm · CMC (8·L + 2) µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks PP-11.09
18 Weld gauges Calibration – length
0 mm to 100 mm · CMC 20 µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks PP-11.12
19 Feeler gauges Calibration – length
0 mm to 10 mm · CMC (20·L + 0,6) µm
CMC for the field of measured quantity: Length
Measurement on a length gauge PP-11.13
20 Adjustable gauges for ultrasonic equipment Calibration – length
0 mm to 250 mm · CMC (8·L + 1) µm
CMC for the field of measured quantity: Length
Measurement on a length gauge PP-11.13
21 Wedges for joints Calibration – length
0 mm to 30 mm · CMC 15 µm
CMC for the field of measured quantity: Length
Measurement by a length sensor PP-11.13
22 Dial indicators Calibration – length
0 mm to 100 mm · CMC (4·L + 0,5) µm
CMC for the field of measured quantity: Length
Measurement on a dial indicator instrument PP-11.14
23 Calibration foils Calibration – length
0 mm to 20 mm · CMC (70·L + 0,5) µm
CMC for the field of measured quantity: Length
Measurement on a length gauge PP-11.15
24 Layer thickness measuring devices Calibration – length
0 mm to 1,5 mm · CMC 1,3 µm
CMC for the field of measured quantity: Length
Measurement with calibration sheets and layer thickness reference standards PP-11.16
25 Cylindrical, flat and slot gauges Calibration – length
0 mm to 300 mm · CMC (5·L + 0,7) µm
CMC for the field of measured quantity: Length
Measurement on a length gauge PP-11.17
26 Sphere Calibration – length
0 mm to 50 mm · CMC (5·L + 0,7) µm
CMC for the field of measured quantity: Length
Measurement on a length gauge PP-11.17
27 Rigid inside micrometers, check tubes Calibration – length
0 mm to 1000 mm · CMC (9·L + 1) µm 1000 mm to 3000 mm · CMC (10·L + 1,5) µm
CMC for the field of measured quantity: Length
Measurement on a length gauge PP-11.17
28 Measuring wires Calibration – length
0,17 mm to 6,35 mm · CMC 0,5 µm
CMC for the field of measured quantity: Length
Measurement on a length gauge PP-11.17
29 Cylindrical gauges Calibration – length
0 mm to 20 mm · CMC 0,5 µm
CMC for the field of measured quantity: Length
Measurement on a length gauge PP-11.17
30 Film thickness standards Calibration – length
0 mm to 0,5 mm · CMC (0,01·l + 2,3) µm 0,5 mm to 1,5 mm · CMC 8,5 µm
CMC for the field of measured quantity: Length
Measurement by a layer thickness measuring instrument PP-11.18
31 Thickness gauges with dial indicator Calibration – length
0 mm to 100 mm · CMC 1,5 µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks PP-11.22
32 Dial indicators with measuring arms for external measurement Calibration – length
0 mm to 300 mm · CMC (10·L + 1,5) µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks PP-11.22
33 Dial indicators with measuring arms for internal measurement Calibration – length
0 mm to 300 mm · CMC (7·L + 1) µm
CMC for the field of measured quantity: Length
Measurement using setting rings and parallel gauge blocks PP-11.22
34 Internal gauge with dial indicator Calibration – length
0 mm to 300 mm · CMC 2 µm
CMC for the field of measured quantity: Length
Measurement on a dial indicator instrument PP-11.22
35 Depth gauges with dial indicator Calibration – length
0 mm to 150 mm · CMC (8·L + 2) µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks PP-11.22
36 Length sensors Calibration – length
0 mm to 100 mm · CMC (4·L + 0,45) µm
CMC for the field of measured quantity: Length
Measurement on a length gauge PP-11.23
37 Roller length gauges Calibration – length
0 m to 250 m · CMC (0,003·L + 0,13) m
CMC for the field of measured quantity: Length
Measurement using tape measures PP-11.29
38 Limit and end measuring rings Calibration – length
1 mm to 300 mm · CMC (4·L + 0,7) µm
CMC for the field of measured quantity: Length
Comparison on a length gauge with a setting ring PP-11.31
39 Snap gauges Calibration – length
1 mm to 300 mm · CMC (4·L + 0,7) µm
CMC for the field of measured quantity: Length
Comparison on a length gauge with a setting ring PP-11.31
40 Ultrasonic thickness gauges Calibration – length
0 mm to 200 mm · CMC 10 µm
CMC for the field of measured quantity: Length
Measurement using ultrasonic gauges PP-11.32
41 Thread gauges – male gauges, cylindrical and conical Calibration – length
0 mm to 300 mm · CMC (5,5·L + 3) µm
CMC for the field of measured quantity: Length
Measurement on a length gauge, microscope and height gauge PP-11.33
42 Thread gauges – rings, cylindrical and conical Calibration – length
2 mm to 16 mm · CMC (5,5·L + 3) µm
CMC for the field of measured quantity: Length
Comparison with a threaded wear gauge PP-11.34
43 Thread gauges – rings, cylindrical and conical Calibration – length
3,5 mm to 300 mm · CMC (2·L + 3,3) µm
CMC for the field of measured quantity: Length
Comparison on a length gauge with a setting ring PP-11.34
44 Straightness / Rules Calibration – length
length up to 1,000 mm — -1 mm to 1 mm · CMC (3·L + 3,5) µm 1,000 mm to 2,000 mm — -1 mm to 1 mm · CMC (6·L + 5) µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks from a reference plane PP-11.45
45 Straightness / Check bars Calibration – length
length up to 4,000 mm — -5 mm to 5 mm · CMC 40 µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks from a reference plane PP-11.45
46 Measuring microscopes, profile projectors Calibration – length
0 mm to 300 mm · CMC 2 µm
CMC for the field of measured quantity: Length
Measurement using a glass gauge PP-11.48
47 Length measuring instruments Calibration – length
0 mm to 500 mm · CMC (3·L + 0,15) µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks PP-11.58
48 Templates, measuring wedges, scales, special gauges, special measuring instruments and fixtures Calibration – length
0 mm to 160 mm · CMC (5·L + 4,5) µm
CMC for the field of measured quantity: Length
Measurement on a 3D microscope PP-11.59
49 Length gauges, measuring microscopes and profile projectors, measuring systems, coordinate measuring machines, line scales Calibration – length
0 mm to 40 m · CMC (1·L + 0,1) µm
CMC for the field of measured quantity: Length
Measurement by a laser interferometer PP-11.50
50 Straightness / Surface rules and blocks Calibration – length
0 mm to 15 m · CMC (1,6·M + 0,1) µm
CMC for the field of measured quantity: Length
Measurement by a laser interferometer PP-11.50
51 Flatness / Surface plates Calibration – length
0 mm to 15 m · CMC (1,6·M + 0,1) µm
CMC for the field of measured quantity: Length
Measurement by a laser interferometer PP-11.50
52 Instruments for the calibration of parallel gauge blocks (comparators) Calibration – length
length up to 100 mm — -10 µm to 10 µm · CMC 0,04 µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks PP-11.57
53 Perpendicularity deviation / Angles Calibration – length
length up to 630 mm — -10 mm to 10 mm · CMC (10·H + 5) µm 630 mm to 1,000 mm — -10 mm to 10 mm · CMC 35 µm 1,000 mm to 2,000 mm — -10 mm to 10 mm · CMC 75 µm
CMC for the field of measured quantity: Length
Measurement using parallel gauge blocks and perpendicularity standard PP-11.04
54 Angle standards, perpendicularity cylinders, sine rulers, prismatic blocks, templates, special gauges, special meters and fixtures, male gauges, rings, calipers, surface plates, rulers Calibration – length
0 mm to 1500 mm · CMC (4,3·L + 1) µm
CMC for the field of measured quantity: Length
Measurement on a 3D coordinate measuring machine PP-11.52
55 Contact roughness measuring instruments – roughness gauges Calibration – length
0,1 µm to 800 µm · CMC 3,6 %
CMC for the field of measured quantity: Length
Measurement using roughness reference plates PP-11.49
56 Roughness standards and templates Calibration – length
0,1 µm to 800 µm · CMC 0,07 µm
CMC for the field of measured quantity: Length
Contact measurement with roughness gauge PP-11.49
57 Angle gauges Calibration – plane angle
0° to 360° · CMC 2´
CMC for the field of measured quantity: Plane angle
Measurement using angle gauges PP-11.07
58 Engineering and electronic levels Calibration – plane angle
-2 mm/m to 2 mm/m · CMC 4 µm/m
CMC for the field of measured quantity: Plane angle
Measurement on a small angle generator PP-11.37
59 Engineering and electronic levels Calibration – plane angle
-20 mm/m to 20 mm/m · CMC 8 µm/m
CMC for the field of measured quantity: Plane angle
Measurement using sine bars and parallel gauge blocks PP-11.37
60 Builder's levels Calibration – plane angle
length up to 2m — -2 mm/m to 2 mm/m · CMC 0,18 mm/m
CMC for the field of measured quantity: Plane angle
Microscope measurements in relation to the horizontal plane PP-11.37
61 Clinometers Calibration – plane angle
-90° to 90° · CMC 9´´
CMC for the field of measured quantity: Plane angle
PP-11.37
62 Electronic and mechanical scales with non-automatic operation Calibration – mass
Weight E2, F1 — 1 mg to 20 kg · CMC 5.10⁻⁶ + 5 µg F1, M1 — 20 kg to 100 kg · CMC 5.10⁻⁵
CMC for the field of measured quantity: Mass
Comparative measurement with standard weights PP-11.75
63 Torque wrenches and screwdrivers Calibration – torque
0,1 Nm to 0,5 Nm · CMC 1 % 0,5 Nm to 1500 Nm · CMC 0,5 %
CMC for the field of measured quantity: Torque
Measurement by a torque sensor PP-11.70
64 Direct indication electronic thermometers Calibration – temperature
-30 °C to 100 °C · CMC 0,10 °C 100 °C to 300 °C · CMC 0,20 °C 300 °C to 500 °C · CMC 0,40 °C 500 °C to 650 °C · CMC 0,60 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermometer in a dry block PP-11.90
65 Direct indication electronic contact thermometers Calibration – temperature
-30 °C to 100 °C · CMC 2 °C 100 °C to 200 °C · CMC 3 °C 200 °C to 300 °C · CMC 5 °C 300 °C to 500 °C · CMC 6 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermometer in a dry block PP-11.90
66 Thermometers for air temperature measurement, data loggers, outdoor thermometers Calibration – temperature
-10 °C to 100 °C · CMC 0,3 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermometer in a climatic chamber PP-11.91
67 Non-contact thermometers Calibration – temperature
35 °C to 100 °C · CMC 1,3 °C 100 °C to 300 °C · CMC 2,2 °C 300 °C to 500 °C · CMC 3,3 °C
CMC for the field of measured quantity: Temperature
Comparison with black body PP-11.92
68 Hygrometers, measuring chains for measuring relative humidity, data loggers for measuring relative humidity Calibration – humidity
30 °C to 50 °C — 10 % RH to 30 % RH · CMC 1,5 % RH 13 °C to 33 °C — 30 % RH to 50 % RH · CMC 1,5 % RH 13 °C to 33 °C — 50 % RH to 70 % RH · CMC 2,0 % RH 13 °C to 33 °C — 70 % RH to 90 % RH · CMC 2,5 % RH
CMC for the field of measured quantity: Humidity
Comparison with a standard hygrometer in a climatic chamber PP-11.95

Reference standards (36)

PP-11.01
PP-11.02
PP-11.04
PP-11.05
PP-11.06
PP-11.07
PP-11.09
PP-11.12
PP-11.13
PP-11.14
PP-11.15
PP-11.16
PP-11.17
PP-11.18
PP-11.22
PP-11.23
PP-11.29
PP-11.31
PP-11.32
PP-11.33
PP-11.34
PP-11.37
PP-11.45
PP-11.48
PP-11.49
PP-11.50
PP-11.52
PP-11.57
PP-11.58
PP-11.59
PP-11.70
PP-11.75
PP-11.90
PP-11.91
PP-11.92
PP-11.95

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/2310