🇨🇿 DEKRA CZ a.s. PL

ČIA 2269 • Praha, Czech Republic • 54 calibration items

Metrology & calibration

DEKRA CZ a.s. is a calibration laboratory accredited by ČIA under number 2269 (Praha, Czech Republic). Its accreditation scope covers 54 calibration items in the following areas: Metrology & calibration. Calibrated items include: DC resistance / resistance meters, AC current / AC current meters, AC current / clamp meters, AC voltage / AC voltage meters. Most frequently used calibration principles: Measurement with a theodolite, Measurement with gauge blocks, Comparison with a reference digital pressure gauge.

At a glance

  • Accreditation number: ČIA 2269
  • Calibration items in scope: 54
  • Types of calibrated items: 26
  • Calibration principles used: 17
  • City: Praha, Czech Republic
  • Valid until: 29-11-2026
Accreditation number
2269
Accreditation body
ČIA
Address
Türkova 1001/9, Chodov, 149 00 Praha 4
City
Praha, Czech Republic
Division
Laboratorium wzorcujące
Valid until
29-11-2026

What this laboratory calibrates (26)

Calibration principles (17)

Laboratory sections (2)

Laboratory locations

Certificate information

Certificate date
29.11.2021

Accreditation scope — calibration items (54)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Prague
1 Micrometer Calibration – length
0 mm to 200 mm · CMC 1,5 µm
CMC for the field of measured quantity: Length
Measurement with gauge blocks KM 2/2010
2 Vernier calliper, depth gauge Calibration – length
0 mm to 500 mm · CMC 12 µm
CMC for the field of measured quantity: Length
Measurement with gauge blocks KM 1/2000
3 Dial indicator Calibration – length
0 mm to 25 mm · CMC 3 µm
CMC for the field of measured quantity: Length
Measurement with a micrometer head KM 1/2001
4 Feeler gauge Calibration – length
0,02 mm to 2 mm · CMC 1,5 µm
CMC for the field of measured quantity: Length
Measurement with gauge blocks KM 1/2003
5 Wheel run-out tester – run-out indicator Calibration – length
-7 mm to 7 mm · CMC 14 µm
CMC for the field of measured quantity: Length
Measurement with a micrometer head with a contact probe KM 2/1998, kap. 7.2
6 Wheel run-out tester – roller run-out Calibration – length
0 mm to 3 mm · CMC 12 µm
CMC for the field of measured quantity: Length
Measurement with a micrometer head with a contact probe KM 2/1998, kap. 7.2
7 Headlight tester (vertical angle) Calibration – plane angle
-78 ´ to +228 ´ · CMC 0,2´ -22,71 cm/10 m to +66,41 cm/10 m · CMC 0,6 mm/10 m
CMC for the field of measured quantity: Plane angle
Measurement with a theodolite KM 1/1998, kap. 7.7.4
8 Headlight tester (horizontal angle) Calibration – plane angle
-39 ´ to +39 ´ · CMC 0,2´ -11,34 cm/10 m to +11,34 cm/10 m · CMC 0,6 mm/10 m
CMC for the field of measured quantity: Plane angle
Measurement with a theodolite KM 1/1998, kap. 7.7.4
9 Flatness of vehicle standing areas and headlight tester track Calibration – plane angle
-5 ´ to +5 ´ · CMC 0,2´ -14,44 mm/10 m to +14,44 mm/10 m · CMC 0,6 mm/10 m
CMC for the field of measured quantity: Plane angle
Measurement with a theodolite KM 1/1998, kap. 7.7.2 až 7.7.3
10 Wheel alignment gauge Calibration – plane angle
-30 ° to +30 ° · CMC 0,5´
CMC for the field of measured quantity: Plane angle
Measurement with a square with a micrometer head and a plumb line KM 1/1997
11 Deceleration – decelerometer Calibration – mechanical motion
0 m/s² to 9,81 m/s² · CMC 0,07 m/s²
CMC for the field of measured quantity: Mechanical motion
Measurement with a protractor KM 1/1995, kap. 7.2
12 Pedal force meter – actuating forces Calibration – force, mechanical tests
20 N to 1000 N · CMC 6 N
CMC for the field of measured quantity: Force, mechanical tests
Measurement using a calibration lever and weights KM 1/1995, kap. 7.4; KM 3/1998, kap. 7.5.4
13 Roller brake tester – braking force Calibration – force, mechanical tests
50 N to 6500 N · CMC 39 N 6500 N to 30000 N · CMC 120 N
CMC for the field of measured quantity: Force, mechanical tests
Measurement using a calibration lever and weights KM 3/1998, kap. 7.5.1
14 Torque wrench, clockwise direction Calibration – force, mechanical tests
0,5 Nm to 1 Nm · CMC 0,7 % 1 Nm to 1400 Nm · CMC 0,6 %
CMC for the field of measured quantity: Force, mechanical tests
Comparison with a reference torque transducer KM 2/1999
15 Deformation pressure gauges, digital pressure gauges. Pressure gauges as part of roller brake testers of road vehicles, pressure gauges as part of instruments for measuring braking deceleration, so-called decelerometers Calibration – pressure, mechanical stress
Relative pressure – gas — -95 kPa to 0 kPa · CMC 0,4 kPa Relative pressure – gas — 0 kPa to 100 kPa · CMC 0,14 % + 0,04 kPa Relative pressure – gas — 100 kPa to 7000 kPa · CMC 0,18 % Relative pressure – liquid — 7 MPa to 14 MPa · CMC 25 kPa Relative pressure – liquid — 14 MPa to 70 MPa · CMC 0,18 %
CMC for the field of measured quantity: Pressure, mechanical stress
Comparison with a reference digital pressure gauge KM 1/2004, KM 2/2004
16 Instruments for measuring air pressure and inflating tyres of road vehicles Calibration – pressure, mechanical stress
Relative pressure — 0 kPa to 400 kPa · CMC 1,2 kPa Relative pressure — 400 kPa to 2000 kPa · CMC 0,3 %
CMC for the field of measured quantity: Pressure, mechanical stress
Comparison with a reference digital pressure gauge KM 4/1998, KM 4/1998 kap. 7.5.5, KM 1/1995 kap. 7.6
17 Direct-reading thermometers and temperature measuring chains Calibration – temperature
-30 °C to 140 °C · CMC 0,10 °C
CMC for the field of measured quantity: Temperature
Comparison with a reference thermometer in a dry-block calibrator KM 3/2006
18 Non-contact thermometers Calibration – temperature
50 °C to 500 °C · CMC 0,007 t +1,5 °C
CMC for the field of measured quantity: Temperature
Direct measurement on a reference black body KM 2/2006
19 DC voltage / DC voltage meters Calibration – electrical quantities
0 µV to 20 mV · CMC 0,0053 % + 6 µV 20 mV to 200 mV · CMC 0,0016 % + 8 µV 200 mV to 2 V · CMC 0,0012 % + 10 µV 2 V to 20 V · CMC 0,0010 % + 50 µV 20 V to 240 V · CMC 0,0016 % + 500 µV 240 V to 1000 V · CMC 0,0050 % + 20 mV
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a voltage calibrator KM 1/2002, KM 1/2006
20 DC current / DC current meters Calibration – electrical quantities
1 µA to 200 µA · CMC 0,050 % + 0,02 µA 200 µA to 2 mA · CMC 0,020 % + 0,1 µA 2 mA to 20 mA · CMC 0,010 % + 0,6 µA 20 mA to 200 mA · CMC 0,010 % + 6 µA 200 mA to 2 A · CMC 0,016 % + 100 µA 2 A to 20 A · CMC 0,021 % + 2 mA 20 A to 30 A · CMC 0,050 % + 2 mA
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a current calibrator KM 1/2002, KM 1/2006
21 DC current / clamp meters Calibration – electrical quantities
100 mA to 1 A · CMC 0,31 % + 43 µA 1 A to 10 A · CMC 0,31 % + 0,43 mA 10 A to 100 A · CMC 0,32 % + 7,1 mA 100 A to 1000 A · CMC 0,33 % + 0,14 A 1000 A to 1500 A · CMC 0,37 % + 0,14 A
CMC for the field of measured quantity: Electrical quantities
Indirect measurement with a current calibrator using a current coil KM 1/2002, KM 1/2006
22 AC voltage / AC voltage meters Calibration – electrical quantities
20 Hz to 10 kHz — 1 mV to 20 mV · CMC 0,20 % + 30 µV 10 kHz to 50 kHz — 1 mV to 20 mV · CMC 0,20 % + 30 µV 20 Hz to 10 kHz — 20 mV to 200 mV · CMC 0,10 % + 80 µV 10 kHz to 50 kHz — 20 mV to 200 mV · CMC 0,15 % + 120 µV 20 Hz to 10 kHz — 200 mV to 2 V · CMC 0,018 % + 100 µV 10 kHz to 50 kHz — 200 mV to 2 V · CMC 0,052 % + 200 µV 20 Hz to 10 kHz — 2 V to 20 V · CMC 0,018 % + 1 mV 10 kHz to 50 kHz — 2 V to 20 V · CMC 0,052 % + 6 mV 20 Hz to 10 kHz — 20 V to 200 V · CMC 0,019 % + 10 mV 20 Hz to 1 kHz — 200 V to 240 V · CMC 0,019 % + 10 mV 20 Hz to 1 kHz — 240 V to 1000 V · CMC 0,031 % + 0,2 V
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a voltage calibrator KM 1/2002, KM 1/2006
23 AC current / AC current meters Calibration – electrical quantities
20 Hz to 1 kHz — 1 µA to 200 µA · CMC 0,15 % + 0,02 µA 1 kHz to 5 kHz — 1 µA to 200 µA · CMC 0,30 % + 0,22 µA 20 Hz to 1 kHz — 200 µA to 2 mA · CMC 0,073 % + 0,2 µA 1 kHz to 5 kHz — 200 µA to 2 mA · CMC 0,20 % + 1 µA 20 Hz to 1 kHz — 2 mA to 20 mA · CMC 0,054 % + 1 µA 1 kHz to 5 kHz — 2 mA to 20 mA · CMC 0,20 % + 10 µA 20 Hz to 1 kHz — 20 mA to 200 mA · CMC 0,054 % + 10 µA 1 kHz to 5 kHz — 20 mA to 200 mA · CMC 0,20 % + 100 µA 20 Hz to 1 kHz — 200 mA to 2 A · CMC 0,056 % + 100 µA 20 Hz to 1 kHz — 2 A to 20 A · CMC 0,11 % + 6 mA 20 Hz to 0,5 kHz — 20 A to 30 A · CMC 0,14 % + 6 mA
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a current calibrator KM 1/2002, KM 1/2006
24 AC current / clamp meters Calibration – electrical quantities
20 Hz to 1 kHz — 100 mA to 1 A · CMC 0,37 % + 71 µA 20 Hz to 1 kHz — 1 A to 10 A · CMC 0,37 % + 710 µA 20 Hz to 1 kHz — 10 A to 100 A · CMC 0,37 % + 7,1 mA 20 Hz to 0,5 kHz — 100 A to 1000 A · CMC 0,44 % + 0,43 A 20 Hz to 0,5 kHz — 1000 A to 1500 A · CMC 0,49 % + 0,43 A
CMC for the field of measured quantity: Electrical quantities
Indirect measurement with a current calibrator using a current coil KM 1/2002, KM 1/2006
25 DC resistance / resistance meters Calibration – electrical quantities
300 kΩ · CMC 0,010 % 1,8 MΩ · CMC 0,030 % 3 MΩ · CMC 0,030 % 18 MΩ · CMC 0,030 % 27 MΩ · CMC 0,060 % 180 MΩ · CMC 0,060 % 1,8 GΩ · CMC 0,36 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement of a reference resistor KM 1/2002
26 DC resistance / resistance meters Calibration – electrical quantities
0 Ω to 10 Ω · CMC 0,030 % + 5 mΩ 10 Ω to 33 Ω · CMC 0,015 % + 5 mΩ 33 Ω to 100 Ω · CMC 0,010 % + 5 mΩ 100 Ω to 330 Ω · CMC 0,010 % + 5 mΩ 330 Ω to 1 MΩ · CMC 0,010 % 1 MΩ to 3,3 MΩ · CMC 0,020 % 3,3 MΩ to 10 MΩ · CMC 0,050 % 10 MΩ to 33 MΩ · CMC 0,10 % 33 MΩ to 100 MΩ · CMC 0,20 % 100 MΩ to 1000 MΩ · CMC 0,50 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a resistance calibrator KM 1/2002
27 DC resistance / resistance standards, resistance decades Calibration – electrical quantities
100 µΩ to 100 Ω · CMC 0,010 % + 4 mΩ 100 Ω to 1 kΩ · CMC 0,010 % 1 kΩ to 100 kΩ · CMC 0,010 % 100 kΩ to 1 MΩ · CMC 0,010 % 1 MΩ to 10 MΩ · CMC 0,040 % 10 MΩ to 100 MΩ · CMC 0,80 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a reference multimeter KM 2/2002
Brno
28 Micrometer Calibration – length
0 mm to 200 mm · CMC 1,5 µm
CMC for the field of measured quantity: Length
Measurement with gauge blocks KM 2/2010
29 Vernier calliper, depth gauge Calibration – length
0 mm to 500 mm · CMC 12 µm
CMC for the field of measured quantity: Length
Measurement with gauge blocks KM 1/2000
30 Dial indicator Calibration – length
0 mm to 25 mm · CMC 3 µm
CMC for the field of measured quantity: Length
Measurement with a micrometer head KM 1/2001
31 Feeler gauge Calibration – length
0,02 mm to 2 mm · CMC 1,5 µm
CMC for the field of measured quantity: Length
Measurement with gauge blocks KM 1/2003
32 Wheel run-out tester – run-out indicator Calibration – length
-7 mm to 7 mm · CMC 14 µm
CMC for the field of measured quantity: Length
Measurement with a micrometer head with a contact probe KM 2/1998, kap. 7.2
33 Wheel run-out tester – roller run-out Calibration – length
0 mm to 3 mm · CMC 12 µm
CMC for the field of measured quantity: Length
Measurement with a micrometer head with a contact probe KM 2/1998, kap. 7.2
34 Headlight tester (vertical angle) Calibration – plane angle
-78 ´ to +228 ´ · CMC 0,2´ -22,71 cm/10 m to +66,41 cm/10 m · CMC 0,6 mm/10 m
CMC for the field of measured quantity: Plane angle
Measurement with a theodolite KM 1/1998, kap. 7.7.4
35 Headlight tester (horizontal angle) Calibration – plane angle
-39 ´ to +39 ´ · CMC 0,2´ -11,34 cm/10 m to +11,34 cm/10 m · CMC 0,6 mm/10 m
CMC for the field of measured quantity: Plane angle
Measurement with a theodolite KM 1/1998, kap. 7.7.4
36 Flatness of vehicle standing areas and headlight tester track Calibration – plane angle
-5 ´ to +5 ´ · CMC 0,2´ -14,44 mm/10 m to +14,44 mm/10 m · CMC 0,6 mm/10 m
CMC for the field of measured quantity: Plane angle
Measurement with a theodolite KM 1/1998, kap. 7.7.2 až 7.7.3
37 Wheel alignment gauge Calibration – plane angle
-30 ° to +30 ° · CMC 0,5´
CMC for the field of measured quantity: Plane angle
Measurement with a square with a micrometer head and a plumb line KM 1/1997
38 Deceleration – decelerometer Calibration – mechanical motion
0 m/s² to 9,81 m/s² · CMC 0,07 m/s²
CMC for the field of measured quantity: Mechanical motion
Measurement with a protractor KM 1/1995, kap. 7.2
39 Pedal force meter – actuating forces Calibration – force, mechanical tests
20 N to 1000 N · CMC 6 N
CMC for the field of measured quantity: Force, mechanical tests
Measurement using a calibration lever and weights KM 1/1995, kap. 7.4; KM 3/1998, kap. 7.5.4
40 Roller brake tester – braking force Calibration – force, mechanical tests
50 N to 6500 N · CMC 39 N 6500 N to 30000 N · CMC 120 N
CMC for the field of measured quantity: Force, mechanical tests
Measurement using a calibration lever and weights KM 3/1998, kap. 7.5.1
41 Torque wrench, clockwise direction Calibration – force, mechanical tests
0,5 Nm to 1 Nm · CMC 0,7 % 1 Nm to 1400 Nm · CMC 0,6 %
CMC for the field of measured quantity: Force, mechanical tests
Comparison with a reference torque transducer KM 2/1999
42 Deformation pressure gauges, digital pressure gauges. Pressure gauges as part of roller brake testers of road vehicles, pressure gauges as part of instruments for measuring braking deceleration, so-called decelerometers Calibration – pressure, mechanical stress
Relative pressure – gas — -95 kPa to 0 kPa · CMC 0,4 kPa Relative pressure – gas — 0 kPa to 100 kPa · CMC 0,14 % + 0,04 kPa Relative pressure – gas — 100 kPa to 7000 kPa · CMC 0,18 % Relative pressure – liquid — 7 MPa to 14 MPa · CMC 25 kPa Relative pressure – liquid — 14 MPa to 70 MPa · CMC 0,18 %
CMC for the field of measured quantity: Pressure, mechanical stress
Comparison with a reference digital pressure gauge KM 1/2004, KM 2/2004
43 Instruments for measuring air pressure and inflating tyres of road vehicles Calibration – pressure, mechanical stress
Relative pressure — 0 kPa to 400 kPa · CMC 1,2 kPa Relative pressure — 400 kPa to 2000 kPa · CMC 0,3 %
CMC for the field of measured quantity: Pressure, mechanical stress
Comparison with a reference digital pressure gauge KM 4/1998, KM 4/1998 kap. 7.5.5, KM 1/1995 kap. 7.6
44 Direct-reading thermometers and temperature measuring chains Calibration – temperature
-30 °C to 140 °C · CMC 0,10 °C
CMC for the field of measured quantity: Temperature
Comparison with a reference thermometer in a dry-block calibrator KM 3/2006
45 Non-contact thermometers Calibration – temperature
50 °C to 500 °C · CMC 0,007 t +1,5 °C
CMC for the field of measured quantity: Temperature
Direct measurement on a reference black body KM 2/2006
46 DC voltage / DC voltage meters Calibration – electrical quantities
0 µV to 20 mV · CMC 0,0053 % + 6 µV 20 mV to 200 mV · CMC 0,0016 % + 8 µV 200 mV to 2 V · CMC 0,0012 % + 10 µV 2 V to 20 V · CMC 0,0010 % + 50 µV 20 V to 240 V · CMC 0,0016 % + 500 µV 240 V to 1000 V · CMC 0,0050 % + 20 mV
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a voltage calibrator KM 1/2002, KM 1/2006
47 DC current / DC current meters Calibration – electrical quantities
1 µA to 200 µA · CMC 0,050 % + 0,02 µA 200 µA to 2 mA · CMC 0,020 % + 0,1 µA 2 mA to 20 mA · CMC 0,010 % + 0,6 µA 20 mA to 200 mA · CMC 0,010 % + 6 µA 200 mA to 2 A · CMC 0,016 % + 100 µA 2 A to 20 A · CMC 0,021 % + 2 mA 20 A to 30 A · CMC 0,050 % + 2 mA
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a current calibrator KM 1/2002, KM 1/2006
48 DC current / clamp meters Calibration – electrical quantities
100 mA to 1 A · CMC 0,31 % + 43 µA 1 A to 10 A · CMC 0,31 % + 0,43 mA 10 A to 100 A · CMC 0,32 % + 7,1 mA 100 A to 1000 A · CMC 0,33 % + 0,14 A 1000 A to 1500 A · CMC 0,37 % + 0,14 A
CMC for the field of measured quantity: Electrical quantities
Indirect measurement with a current calibrator using a current coil KM 1/2002, KM 1/2006
49 AC voltage / AC voltage meters Calibration – electrical quantities
20 Hz to 10 kHz — 1 mV to 20 mV · CMC 0,20 % + 30 µV 10 kHz to 50 kHz — 1 mV to 20 mV · CMC 0,20 % + 30 µV 20 Hz to 10 kHz — 20 mV to 200 mV · CMC 0,10 % + 80 µV 10 kHz to 50 kHz — 20 mV to 200 mV · CMC 0,15 % + 120 µV 20 Hz to 10 kHz — 200 mV to 2 V · CMC 0,018 % + 100 µV 10 kHz to 50 kHz — 200 mV to 2 V · CMC 0,052 % + 200 µV 20 Hz to 10 kHz — 2 V to 20 V · CMC 0,018 % + 1 mV 10 kHz to 50 kHz — 2 V to 20 V · CMC 0,052 % + 6 mV 20 Hz to 10 kHz — 20 V to 200 V · CMC 0,019 % + 10 mV 20 Hz to 1 kHz — 200 V to 240 V · CMC 0,019 % + 10 mV 20 Hz to 1 kHz — 240 V to 1000 V · CMC 0,031 % + 0,2 V
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a voltage calibrator KM 1/2002, KM 1/2006
50 AC current / AC current meters Calibration – electrical quantities
20 Hz to 1 kHz — 1 µA to 200 µA · CMC 0,15 % + 0,02 µA 1 kHz to 5 kHz — 1 µA to 200 µA · CMC 0,30 % + 0,22 µA 20 Hz to 1 kHz — 200 µA to 2 mA · CMC 0,073 % + 0,2 µA 1 kHz to 5 kHz — 200 µA to 2 mA · CMC 0,20 % + 1 µA 20 Hz to 1 kHz — 2 mA to 20 mA · CMC 0,054 % + 1 µA 1 kHz to 5 kHz — 2 mA to 20 mA · CMC 0,20 % + 10 µA 20 Hz to 1 kHz — 20 mA to 200 mA · CMC 0,054 % + 10 µA 1 kHz to 5 kHz — 20 mA to 200 mA · CMC 0,20 % + 100 µA 20 Hz to 1 kHz — 200 mA to 2 A · CMC 0,056 % + 100 µA 20 Hz to 1 kHz — 2 A to 20 A · CMC 0,11 % + 6 mA 20 Hz to 0,5 kHz — 20 A to 30 A · CMC 0,14 % + 6 mA
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a current calibrator KM 1/2002, KM 1/2006
51 AC current / clamp meters Calibration – electrical quantities
20 Hz to 1 kHz — 100 mA to 1 A · CMC 0,37 % + 71 µA 20 Hz to 1 kHz — 1 A to 10 A · CMC 0,37 % + 710 µA 20 Hz to 1 kHz — 10 A to 100 A · CMC 0,37 % + 7,1 mA 20 Hz to 0,5 kHz — 100 A to 1000 A · CMC 0,44 % + 0,43 A 20 Hz to 0,5 kHz — 1000 A to 1500 A · CMC 0,49 % + 0,43 A
CMC for the field of measured quantity: Electrical quantities
Indirect measurement with a current calibrator using a current coil KM 1/2002, KM 1/2006
52 DC resistance / resistance meters Calibration – electrical quantities
300 kΩ · CMC 0,010 % 1,8 MΩ · CMC 0,030 % 3 MΩ · CMC 0,030 % 18 MΩ · CMC 0,030 % 27 MΩ · CMC 0,060 % 180 MΩ · CMC 0,060 % 1,8 GΩ · CMC 0,36 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement of a reference resistor KM 1/2002
53 DC resistance / resistance meters Calibration – electrical quantities
0 Ω to 10 Ω · CMC 0,030 % + 5 mΩ 10 Ω to 33 Ω · CMC 0,015 % + 5 mΩ 33 Ω to 100 Ω · CMC 0,010 % + 5 mΩ 100 Ω to 330 Ω · CMC 0,010 % + 5 mΩ 330 Ω to 1 MΩ · CMC 0,010 % 1 MΩ to 3,3 MΩ · CMC 0,020 % 3,3 MΩ to 10 MΩ · CMC 0,050 % 10 MΩ to 33 MΩ · CMC 0,10 % 33 MΩ to 100 MΩ · CMC 0,20 % 100 MΩ to 1000 MΩ · CMC 0,50 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a resistance calibrator KM 1/2002
54 DC resistance / resistance standards, resistance decades Calibration – electrical quantities
100 µΩ to 100 Ω · CMC 0,010 % + 4 mΩ 100 Ω to 1 kΩ · CMC 0,010 % 1 kΩ to 100 kΩ · CMC 0,010 % 100 kΩ to 1 MΩ · CMC 0,010 % 1 MΩ to 10 MΩ · CMC 0,040 % 10 MΩ to 100 MΩ · CMC 0,80 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a reference multimeter KM 2/2002

Reference standards (18)

KM 1/1995
KM 1/1997
KM 1/1998
KM 1/2000
KM 1/2001
KM 1/2002
KM 1/2003
KM 1/2004
KM 1/2006
KM 2/1998
KM 2/1999
KM 2/2002
KM 2/2004
KM 2/2006
KM 2/2010
KM 3/1998
KM 3/2006
KM 4/1998

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/2269