Český metrologický institut is a calibration laboratory accredited by ČIA under number 2202 (Brno, Czech Republic). Its accreditation scope covers 402 calibration items in the following areas: Metrology & calibration. Calibrated items include: Indication thermometers including temperature measuring chains, the…, Thermocouple temperature sensors, Balances with non-automatic and automatic function, Mass of weights. Most frequently used calibration principles: Comparison with a reference weight, Loading using a reference weight, Comparison with a reference resistance temperature sensor in liquid….
At a glance
- Accreditation number: ČIA 2202
- Calibration items in scope: 402
- Types of calibrated items: 203
- Calibration principles used: 175
- City: Brno, Czech Republic
- Valid until: 02-12-2026
- Accreditation number
- 2202
- Accreditation body
- ČIA
- Address
- Okružní 772/31, 638 00 Brno
- City
- Brno, Czech Republic
- Division
- CMI Calibration Laboratory
- Valid until
- 02-12-2026
What this laboratory calibrates (203)
- Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers — 21 calibration items
- Thermocouple temperature sensors — 13 calibration items
- Balances with non-automatic and automatic function — 11 calibration items
- Mass of weights — 11 calibration items
- Hardness – hardness testers — 10 calibration items
- Resistance temperature sensors — 10 calibration items
- Machines for mechanical testing of materials — 9 calibration items
- Strain gauges for mechanical testing of materials — 8 calibration items
- Volume and velocity gas meters and flow meters for gas — 7 calibration items
- Force / force-proving instruments — 6 calibration items
- AC voltage ratio / Voltage measuring transformers — 4 calibration items
- DC resistance / DC resistance standards and resistance meters — 4 calibration items
- Digital electrical inspection instruments and related standards / insulation resistance — 4 calibration items
- Ethanol concentration / breath alcohol analyzers — 4 calibration items
- Hardness plates and products — 4 calibration items
- and 188 more
Calibration principles (175)
- Comparison with a reference weight — 11 calibration items
- Loading using a reference weight — 11 calibration items
- Comparison with a reference resistance temperature sensor in liquid bath — 10 calibration items
- Gravimetric method — 10 calibration items
- Comparison with a measuring transformer — 8 calibration items
- Comparison with the standard — 8 calibration items
- Direct comparison with an inspection instrument calibrator — 8 calibration items
- Comparison with a reference resistance temperature sensor in a vertical furnace — 7 calibration items
- Comparison with a reference resistance temperature sensor near the boiling point of nitrogen — 7 calibration items
- Measurement by a reference spectrophotometer — 7 calibration items
- Volume method — 7 calibration items
- Calibration by a force transmission standard (force-proving instrument) or by suspending weights — 5 calibration items
- Comparison with a reference determination — 5 calibration items
- Comparison with a reference resistance temperature sensor at a fixed point — 5 calibration items
- Comparison with a standard using an impedance bridge — 5 calibration items
- and 160 more
Laboratory sections (13)
- Regional Inspectorate Praha — 111 calibration items
- Regional Inspectorate Brno — 105 calibration items
- Primary Metrology Laboratories Praha — 71 calibration items
- Regional Inspectorate Pardubice — 44 calibration items
- Regional Inspectorate Liberec — 25 calibration items
- Regional Inspectorate Opava — 15 calibration items
- Regional Inspectorate Kroměříž — 9 calibration items
- Regional Inspectorate Olomouc — 5 calibration items
- TESTCOM Praha — 5 calibration items
- Regional Inspectorate České Budějovice — 4 calibration items
- Regional Inspectorate Jihlava — 2 calibration items
- Regional Inspectorate Most — 2 calibration items
- Regional Inspectorate Plzeň — 2 calibration items
Laboratory locations
- Český metrologický institut (main site) — Okružní 772/31, 638 00 Brno
- Regional Inspectorate Praha — Radiová 1136/3, 102 00 Praha
- Regional Inspectorate České Budějovice — U Sirkárny 33/5, 370 04 České Budějovice
- Regional Inspectorate Plzeň — Bendova 539/11, 301 00 Plzeň
- Regional Inspectorate Liberec — Slunečná 23, 460 01 Liberec
- Regional Inspectorate Most — Vladislava Vančury 1428/7, 434 01 Most
- Regional Inspectorate Pardubice — Průmyslová 455, 530 03 Pardubice
- Regional Inspectorate Brno — Okružní 31, 638 00 Brno
- Regional Inspectorate Jihlava — Romana Havelky 17, 586 01 Jihlava
- Regional Inspectorate Kroměříž — Kotojedy 73, 767 01 Kroměříž
- Regional Inspectorate Opava — Gudrichova 41, 746 01 Opava
- Regional Inspectorate Olomouc — I. P. Pavlova 671/141, 779 00 Olomouc
- Primary Metrology Laboratories Praha — V Botanice 4, 150 72 Praha
- TESTCOM Praha — Hvožďanská 3, 148 00 Praha
Certificate information
- Certificate date
- 18.12.2025
Accreditation scope — calibration items (402)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Regional Inspectorate Praha | |||||
| 1 | Strain gauges for mechanical testing of materials | Calibration – length from 0 mm to 25 mm · CMC 0,9 µm od 25 mm do 50 mm · CMC 1,3 µm od 50 mm do 1 000 mm · CMC 20 µm CMC for the field of measured quantity: Length |
ČSN EN ISO 9513 | 151-MP-C003 | |
| 2 | Strain gauges for mechanical testing of materials | Calibration – length from 0 mm to 10 mm · CMC 0,9 µm from 10 mm to 50 mm · CMC 1,3 µm od 50 mm do 1 000 mm · CMC 20 µm CMC for the field of measured quantity: Length |
ASTM E83 | 151-MP-C005 | |
| 3 | Mass of weights | Calibration – mass from 1 mg to 20 mg · CMC 0,001 0 mg 50 mg · CMC 0,001 3 mg 100 mg · CMC 0,001 6 mg 200 mg · CMC 0,002 0 mg 500 mg · CMC 0,002 6 mg 1 g · CMC 0,003 mg 2 g · CMC 0,004 mg 5 g · CMC 0,005 mg 10 g · CMC 0,006 mg 20 g · CMC 0,008 mg 50 g · CMC 0,010 mg 100 g · CMC 0,016 mg 200 g · CMC 0,030 mg 500 g · CMC 0,080 mg 1 kg · CMC 0,15 mg 2 kg · CMC 0,30 mg 5 kg · CMC 0,80 mg 10 kg · CMC 1,5 mg 20 kg · CMC 3,3 mg 50 kg · CMC 8 mg 100 kg · CMC 50 mg 200 kg · CMC 100 mg 500 kg · CMC 250 mg 1 000 kg · CMC 500 mg CMC for the field of measured quantity: Mass |
Comparison with a reference weight | 612-MP-C131 | |
| 4 | Balances with non-automatic and automatic function | Calibration – mass Weight E2 — 0 g to 20 kg · CMC 5·10⁻⁷ Weight F1 — 20 kg to 50 kg · CMC 1,6·10⁻⁶ Weight F2 — 50 kg to 600 kg · CMC 5·10⁻⁶ Weight M — 600 kg to 200 000 kg · CMC 1,6·10⁻⁵ CMC for the field of measured quantity: Mass |
Loading using a reference weight | 612-MP-C132 | |
| 5 | Force / force-proving instruments | Calibration – force, mechanical tests 0,02 N to 5 N · CMC 0,002 5 N to 2 MN · CMC 0,001 CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a force transmission standard (force-proving instrument) or by suspending weights | 811-MP-C111 | |
| 6 | Machines for mechanical testing of materials | Calibration – force, mechanical tests Pressure — 0,02 N to 5 MN · CMC 0,20 % Tension — 0,02 N to 2 MN · CMC 0,20 % CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a force transmission standard (force-proving instrument) or weights (ASTM E4, ČSN EN ISO 7500) | 151 MP-C001, 151-MP-C004 | |
| 7 | Machines for mechanical testing of materials | Calibration – force, mechanical tests Self-setting of the upper pressure plate — 200 kN to 2 MN · CMC 0,20 % CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN 12390-4 Annex A | 151-MP-C001 | |
| 8 | Pendulum hammers for notch impact strength testing of materials | Calibration – force, mechanical tests 0,01 J to 2,5 kJ · CMC 0,02 % CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a force transmission standard (force-proving instrument) and length standard (ČSN EN ISO 148-2, ČSN EN ISO 13802, ASTM E23, BS 131-4) | 151-MP-C002 | |
| 9 | Deformation pressure gauges; digital pressure gauges; piston pressure gauges | Calibration – pressure, mechanical stress Absolute pressure; Gas — 1 Pa to 20 Pa · CMC 10 % Absolute pressure; Gas — 20 Pa to 5 000 Pa · CMC 3,5 Pa Absolute pressure; Gas — 5 kPa to 18 kPa · CMC 3,8 Pa Absolute pressure; Gas — 18 kPa to 2 000 kPa · CMC 9·10⁻⁵·p Absolute pressure; Gas — 2 MPa to 8 MPa · CMC 2,3·10⁻⁵·p + 56 Pa Overpressure; Gas — -100 kPa to -10 kPa · CMC 8,5·10⁻⁵·|pe| Overpressure; Gas — -10 kPa to -3,45 kPa · CMC 9,3·10⁻⁵·|pe| Overpressure; Gas — -3,45 kPa to -2 kPa · CMC 32 Pa Overpressure; Gas — -2 000 Pa to -6 Pa · CMC 1,3·10⁻⁴·|pe| + 48 Pa Overpressure; Gas — -6 Pa to +6 Pa · CMC 1,5 Pa Overpressure; Gas — 6 Pa to 2 000 Pa · CMC 1,3·10⁻⁴·pe + 48 Pa Overpressure; Gas — 2 kPa to 3,45 kPa · CMC 32 Pa Overpressure; Gas — 3,45 kPa to 10 kPa · CMC 9,3·10⁻⁵·pe Overpressure; Gas — 10 kPa to 100 kPa · CMC 8,5·10⁻⁵·pe Overpressure; Gas — 100 kPa to 345 kPa · CMC 8,8·10⁻⁵·pe Overpressure; Gas — 345 kPa to 2 000 kPa · CMC 9·10⁻⁵·pe + 1 Pa Overpressure; Gas — 2 MPa to 8 MPa · CMC 2,3·10⁻⁵·pe +55 Pa Absolute pressure p = pe + pamb; Liquid — 20 kPa to 600 kPa · CMC 49 Pa Absolute pressure p = pe + pamb; Liquid — 0,6 MPa to 40 MPa · CMC 8,2·10⁻⁵·pe + 10 Pa Absolute pressure p = pe + pamb; Liquid — 40 MPa to 100 MPa · CMC 8,7·10⁻⁵·pe + 10 Pa Absolute pressure p = pe + pamb; Liquid — 100 MPa to 120 MPa · CMC 1,2·10⁻⁴·pe + 10 Pa Overpressure; Liquid — 20 kPa to 600 kPa · CMC 48 Pa Overpressure; Liquid — 0,6 MPa to 40 MPa · CMC 8,2·10⁻⁵·pe Overpressure; Liquid — 40 MPa to 100 MPa · CMC 8,7·10⁻⁵·pe Overpressure; Liquid — 100 MPa to 120 MPa · CMC 1,2·10⁻⁴·pe CMC for the field of measured quantity: Pressure, mechanical stress |
Cross-floating method, determination of the effective area of the piston-cylinder unit and the mass of weights | 133-MP-C007, 601-MP-C046, 601-MP-C047 | |
| 10 | Pressure sensors and transducers | Calibration – pressure, mechanical stress Absolute pressure; Gas — 1 Pa to 20 Pa · CMC 10 % Absolute pressure; Gas — 20 Pa to 5 000 Pa · CMC 2·10⁻⁵·p + 3,5 Pa Absolute pressure; Gas — 5 kPa to 18 kPa · CMC 2·10⁻⁵·p + 3,8 Pa Absolute pressure; Gas — 18 kPa to 2 000 kPa · CMC 9·10⁻⁵·p Absolute pressure; Gas — 2 MPa to 8 MPa · CMC 3·10⁻⁵·p + 56 Pa Overpressure; Gas — -100 kPa to -10 kPa · CMC 8,6·10⁻⁵·|pe| Overpressure; Gas — -10 kPa to -3,45 kPa · CMC 9,4·10⁻⁵·|pe| Overpressure; Gas — -3,45 kPa to -2 kPa · CMC 2·10⁻⁵·|pe| + 32 Pa Overpressure; Gas — -2 000 Pa to -6 Pa · CMC 1,3·10⁻⁴·|pe| + 48 Pa Overpressure; Gas — -6 Pa to +6 Pa · CMC 1,5 Pa Overpressure; Gas — 6 Pa to 2 000 Pa · CMC 1,3·10⁻⁴·pe + 48 Pa Overpressure; Gas — 2 kPa to 3,45 kPa · CMC 2·10⁻⁵·pe + 32 Pa Overpressure; Gas — 3,45 kPa to 10 kPa · CMC 9,4·10⁻⁵·pe Overpressure; Gas — 10 kPa to 100 kPa · CMC 8,6·10⁻⁵·pe Overpressure; Gas — 100 kPa to 345 kPa · CMC 8,9·10⁻⁵·pe Overpressure; Gas — 345 kPa to 2 000 kPa · CMC 9·10⁻⁵·pe + 1 Pa Overpressure; Gas — 2 MPa to 8 MPa · CMC 3·10⁻⁵·pe +55 Pa Absolute pressure p = pe + pamb; Liquid — 20 kPa to 600 kPa · CMC 2·10⁻⁵·pe + 49 Pa Absolute pressure p = pe + pamb; Liquid — 0,6 MPa to 40 MPa · CMC 8,3·10⁻⁵·pe + 10 Pa Absolute pressure p = pe + pamb; Liquid — 40 MPa to 100 MPa · CMC 8,8·10⁻⁵·pe + 10 Pa Absolute pressure p = pe + pamb; Liquid — 100 MPa to 120 MPa · CMC 1,2·10⁻⁴·pe + 10 Pa Overpressure; Liquid — 20 kPa to 600 kPa · CMC 2·10⁻⁵·pe + 48 Pa Overpressure; Liquid — 0,6 MPa to 40 MPa · CMC 8,3·10⁻⁵·pe Overpressure; Liquid — 40 MPa to 100 MPa · CMC 8,8·10⁻⁵·pe Overpressure; Liquid — 100 MPa to 120 MPa · CMC 1,2·10⁻⁴·pe CMC for the field of measured quantity: Pressure, mechanical stress |
Comparison with a standard pressure gauge | 601-MP-C049 | |
| 11 | Glass thermometers | Calibration – temperature division < 0.1 °C — -90 °C to 100 °C · CMC 0,015 °C division < 0.1 °C — 100 °C to 150 °C · CMC 0,020 °C division < 0.1 °C — 150 °C to 210 °C · CMC 0,040 °C division < 0.1 °C — 210 °C to 360 °C · CMC 0,050 °C 0.1 °C ≤ division ≤ 1 °C — 360 °C to 420 °C · CMC 0,15 °C 0.1 °C ≤ division ≤ 1 °C — 420 °C to 550 °C · CMC 0,20 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in liquid bath | 133-MP-C001 | |
| 12 | Resistance temperature sensors | Calibration – temperature 0,01 °C · CMC 0,002 °C CMC for the field of measured quantity: Temperature |
Direct measurement at triple point of water | 133-MP-C002 | |
| 13 | Resistance temperature sensors | Calibration – temperature 660,32 °C · CMC 0,05 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor at a fixed point | 133-MP-C002 | |
| 14 | Resistance temperature sensors | Calibration – temperature -196 °C · CMC 0,03 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor near the boiling point of nitrogen | 133-MP-C002 | |
| 15 | Resistance temperature sensors | Calibration – temperature od -100 °C do -90 °C · CMC 0,2 °C from 550 °C to 660 °C · CMC 0,09 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in a vertical furnace | 133-MP-C002 | |
| 16 | Resistance temperature sensors | Calibration – temperature from -90 °C to -80 °C · CMC 0,015 °C od -80 °C do 160 °C · CMC 0,01 °C od 160 °C do 300 °C · CMC 0,02 °C from 300 °C to 420 °C · CMC 0,03 °C od 420 °C do 550 °C · CMC 0,05 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in liquid bath | 133-MP-C002 | |
| 17 | Thermocouple temperature sensors | Calibration – temperature Noble metals — 0 °C to 220 °C · CMC 0,4 °C Noble metals — 220 °C to 550 °C · CMC 0,5 °C Base metals — -90 °C to 220 °C · CMC 0,2 °C Base metals — 220 °C to 550 °C · CMC 0,4 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in liquid bath | 133-MP-C003 | |
| 18 | Thermocouple temperature sensors | Calibration – temperature Noble metals — 550 °C to 1 100 °C · CMC 0,8 °C Noble metals — 1 100 °C to 1 300 °C · CMC 1,3 °C Noble metals — 1 300 °C to 1 600 °C · CMC 2,1 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference thermoelectric temperature sensor in a horizontal furnace | 133-MP-C003 | |
| 19 | Thermocouple temperature sensors | Calibration – temperature Base metals — -196 °C · CMC 0,3 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor near the boiling point of nitrogen | 133-MP-C003 | |
| 20 | Thermocouple temperature sensors | Calibration – temperature Base metals — -100 °C to -90 °C · CMC 0,3 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in a vertical furnace | 133-MP-C003 | |
| 21 | Thermocouple temperature sensors | Calibration – temperature Base metals — 550 °C to 1 100 °C · CMC 1,0 °C Base metals — 1 100 °C to 1 300 °C · CMC 1,4 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference thermoelectric temperature sensor in a calibration furnace | 133-MP-C003 | |
| 22 | Thermocouple temperature sensors | Calibration – temperature Thermocouples made of precious metals — 550 °C to 1 100 °C · CMC 0,6 °C Thermocouples made of precious metals — 1 100 °C to 1 324 °C · CMC 1,2 °C Thermocouples made of precious metals — 1 324 °C to 1 554 °C · CMC 1,7 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference thermoelectric temperature sensor in a calibration furnace | 133-MP-C003 | |
| 23 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature 0,01 °C · CMC 0,002 °C CMC for the field of measured quantity: Temperature |
Direct measurement at triple point of water | 133-MP-C004 | |
| 24 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature 660,32 °C · CMC 0,05 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor at a fixed point | 133-MP-C004 | |
| 25 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature -196 °C · CMC 0,03 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor near the boiling point of nitrogen | 133-MP-C004 | |
| 26 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature -196 °C to -100 °C · CMC 0,3 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor on the customer's equipment | 133-MP-C004 | |
| 27 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature od -100 °C do -90 °C · CMC 0,2 °C from 550 °C to 660 °C · CMC 0,09 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in a vertical furnace | 133-MP-C004 | |
| 28 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature from -90 °C to -80 °C · CMC 0,015 °C od -80 °C do 160 °C · CMC 0,01 °C od 160 °C do 300 °C · CMC 0,02 °C from 300 °C to 420 °C · CMC 0,03 °C od 420 °C do 550 °C · CMC 0,05 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in liquid bath | 133-MP-C004 | |
| 29 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature od 550 °C do 1 100 °C · CMC 0,7 °C from 1 100 °C to 1 300 °C · CMC 1,3 °C od 1 300 °C do 1 600 °C · CMC 1,8 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference temperature sensor in a furnace | 133-MP-C004 | |
| 30 | Infrared non-contact thermometers and measuring chains of infrared non-contact thermometers | Calibration – temperature Measuring chains with range limited to (-15 to 500) °C — -30 °C to -15 °C · CMC 2,2 °C Measuring chains with range limited to (-15 to 500) °C — -15 °C to 0 °C · CMC 1,6 °C Measuring chains with range limited to (-15 to 500) °C — 0 °C to 20 °C · CMC 1,1 °C Measuring chains with range limited to (-15 to 500) °C — 20 °C to 100 °C · CMC 0,8 °C Measuring chains with range limited to (-15 to 500) °C — 100 °C to 200 °C · CMC 1,1 °C Measuring chains with range limited to (-15 to 500) °C — 200 °C to 300 °C · CMC 1,4 °C Measuring chains with range limited to (-15 to 500) °C — 300 °C to 400 °C · CMC 1,7 °C Measuring chains with range limited to (-15 to 500) °C — 400 °C to 500 °C · CMC 2,2 °C Measuring chains with range limited to (-15 to 500) °C — 500 °C to 600 °C · CMC 2,6 °C Measuring chains with range limited to (-15 to 500) °C — 600 °C to 700 °C · CMC 2,9 °C CMC for the field of measured quantity: Temperature |
Comparison with the standard | 133-MP-C005 | |
| 31 | Measuring chains | Calibration – temperature "K" type Thermoelectric temperature sensor⁴ — -200 °C to 0 °C · CMC 0,1 % + 0,1 °C "K" type Thermoelectric temperature sensor⁴ — 0 °C to 1 000 °C · CMC 0,007 % + 0,1 °C "K" type Thermoelectric temperature sensor⁴ — 1 000 °C to 1 372 °C · CMC 0,017 % "J" type Thermoelectric temperature sensor⁴ — -200 °C to 0 °C · CMC 0,06 % + 0,08 °C "J" type Thermoelectric temperature sensor⁴ — 0 °C to 1 200 °C · CMC 0,006 % + 0,08 °C "N" type Thermoelectric temperature sensor⁴ — -200 °C to -100 °C · CMC 0,2 % "N" type Thermoelectric temperature sensor⁴ — -100 °C to 0 °C · CMC 0,05 % + 0,15 °C "N" type Thermoelectric temperature sensor⁴ — 0 °C to 800 °C · CMC 0,15 °C "N" type Thermoelectric temperature sensor⁴ — 800 °C to 1 300 °C · CMC 0,01 % + 0,07 °C "S" type Thermoelectric temperature sensor⁴ — 0 °C to 100 °C · CMC 0,7 °C "S" type Thermoelectric temperature sensor⁴ — 100 °C to 300 °C · CMC 0,55 °C "S" type Thermoelectric temperature sensor⁴ — 300 °C to 1 768 °C · CMC 0,45 °C "T" type Thermoelectric temperature sensor⁴ — -200 °C to 0 °C · CMC 0,1 % + 0,1 °C "T" type Thermoelectric temperature sensor⁴ — 0 °C to 400 °C · CMC 0,1 °C "B" type Thermoelectric temperature sensor⁴ — 200 °C to 500 °C · CMC 2 °C "B" type Thermoelectric temperature sensor⁴ — 500 °C to 800 °C · CMC 0,8 °C "B" type Thermoelectric temperature sensor⁴ — 800 °C to 1 820 °C · CMC 0,5 °C "R" type Thermoelectric temperature sensor⁴ — 0 °C to 150 °C · CMC 0,7 °C "R" type Thermoelectric temperature sensor⁴ — 150 °C to 400 °C · CMC 0,45 °C "R" type Thermoelectric temperature sensor⁴ — 400 °C to 1 768 °C · CMC 0,4 °C Pt 100 Resistance temperature sensor — -200 °C to 0 °C · CMC 0,05 °C Pt 100 Resistance temperature sensor — 0 °C to 850 °C · CMC 0,014 % + 0,05 °C Pt 1000 Resistance temperature sensor — -200 °C to -150 °C · CMC 0,011 °C Pt 1000 Resistance temperature sensor — -150 °C to -50 °C · CMC 0,03 °C Pt 1000 Resistance temperature sensor — -50 °C to 0 °C · CMC 0,043 °C Pt 1000 Resistance temperature sensor — 0 °C to 850 °C · CMC 0,019 % + 0,043 °C Voltage output of transducers — -1 V to 1 V · CMC 0,007 % + 4 µV Voltage output of transducers — 1 V to 24 V · CMC 0,007 % + 0,1 mV Current output of transducers — 0 mA to 25 mA · CMC 0,01 % + 1 µA Current output of transducers — 25 mA to 55 mA · CMC 0,01 % + 2 µA CMC for the field of measured quantity: Temperature |
Simulation of sensor electrical input signal | 133-MP-C006 | |
| 32 | Thermocouple temperature sensors | Calibration – temperature In — 156,5985 °C · CMC 0,12 °C Sn — 231,928 °C · CMC 0,12 °C Fe-C — 1 153 °C · CMC 1,0 °C Co-C — 1 324 °C · CMC 0,85 °C CMC for the field of measured quantity: Temperature |
Direct measurement at a fixed point | 112-MP-C002 | |
| 33 | Thermocouple temperature sensors | Calibration – temperature Pd — 1 553,53 °C · CMC 1,5 °C CMC for the field of measured quantity: Temperature |
Measurement by wire method | 112-MP-C002 | |
| 34 | Contactless thermometers | Calibration – temperature Measuring point diameter less than 5 mm; In — 156,5985 °C · CMC 0,2 °C Measuring point diameter less than 5 mm; Sn — 231,928 °C · CMC 0,2 °C Measuring point diameter less than 5 mm; Al — 660,323 °C · CMC 0,15 °C Measuring point diameter less than 5 mm; Cu — 1 084,62 °C · CMC 0,10 °C CMC for the field of measured quantity: Temperature |
Direct measurement at a fixed point | 112-MP-C003 | |
| 35 | Contactless thermometers | Calibration – temperature from 100 °C to 300 °C · CMC 0,5 °C from 300 °C to 600 °C · CMC 0,7 °C od 600 °C do 1 000 °C · CMC 0,8 °C od 1 000 °C do 1 300 °C · CMC 1,0 °C od 1 300 °C do 1 800 °C · CMC 1,5 °C CMC for the field of measured quantity: Temperature |
Comparison with the standard | 112-MP-C003 | |
| 36 | Black bodies | Calibration – temperature -30 °C to 45 °C · CMC 0,2 °C 45 °C to 230 °C · CMC 0,22 °C 230 °C to 600 °C · CMC 0,21 °C CMC for the field of measured quantity: Temperature |
Direct comparison of two black bodies using a transfer thermometer | 112-MP-C004 | |
| 37 | Black bodies | Calibration – temperature 600 °C to 1 000 °C · CMC 0,5 °C 1 000 °C to 1 300 °C · CMC 0,6 °C 1 300 °C to 1 800 °C · CMC 1,0 °C CMC for the field of measured quantity: Temperature |
Comparison with the standard | 112-MP-C004 | |
| 38 | Thermal cameras | Calibration – temperature -30 °C to 500 °C · CMC 0,8 °C 500 °C to 1 000 °C · CMC 1,0 °C 1 000 °C to 1 300 °C · CMC 1,5 °C 1 300 °C to 1 800 °C · CMC 2,0 °C CMC for the field of measured quantity: Temperature |
Comparison with the standard | 112-MP-C005 | |
| 39 | Temperature calibrators | Calibration – temperature TC - R — -50 °C to 1 760 °C · CMC 0,12 °C TC - S — -50 °C to 1 760 °C · CMC 0,16 °C TC - B — 0 °C to 1 820 °C · CMC 0,14 °C TC - J — -210 °C to 1 200 °C · CMC 0,04 °C TC - T — -270 °C to 400 °C · CMC 0,04 °C TC - E — -270 °C to 1 000 °C · CMC 0,04 °C TC - K — -270 °C to 1 370 °C · CMC 0,05 °C TC - N — -270 °C to 1 300 °C · CMC 0,05 °C TC - M — -200 °C to 100 °C · CMC 0,03 °C TC - L — -200 °C to 800 °C · CMC 0,03 °C TC - A — 0 °C to 2 500 °C · CMC 0,24 °C TC – Fe-ko — -200 °C to 900 °C · CMC 0,04 °C RTD - Pt100 — -200 °C to 850 °C · CMC 0,02 °C RTD - Pt200 — -200 °C to 850 °C · CMC 0,02 °C RTD - Pt500 — -200 °C to 850 °C · CMC 0,03 °C RTD - Pt1000 — -200 °C to 850 °C · CMC 0,02 °C RTD - Ni100 — -60 °C to 250 °C · CMC 0,01 °C RTD - Ni1000 — -60 °C to 250 °C · CMC 0,01 °C CMC for the field of measured quantity: Temperature |
Comparison with a calibrator or electrical measurement using a multimeter | 611-MP-C130 | |
| 40 | Relative humidity / hygrometers and humidity measuring chains including humidity probes, characterization of climatic chambers | Calibration – air humidity Air temperature (10 to 90) °C — 5 % RH to 30 % RH · CMC 0,6 % RH Air temperature (10 to 90) °C — 30 % RH to 50 % RH · CMC 0,7 % RH Air temperature (10 to 90) °C — 50 % RH to 70 % RH · CMC 0,8 % RH Air temperature (10 to 90) °C — 70 % RH to 80 % RH · CMC 0,9 % RH Air temperature (10 to 90) °C — 80 % RH to 90 % RH · CMC 1,0 % RH Air temperature (10 to 90) °C — 90 % RH to 95 % RH · CMC 1,5 % RH CMC for the field of measured quantity: Air humidity |
Comparison with a standard hygrometer | 636-MP-C119 | |
| 41 | Dew point temperature at elevated pressure / hygrometers | Calibration – air humidity -60 °C to - 10 °C · CMC 0,08 °C -10 °C to 10 °C · CMC 0,07 °C CMC for the field of measured quantity: Air humidity |
Comparison with a standard thermometer | 112-MP-C006 | |
| 42 | DC voltage / DC voltage sources and meters | Calibration – electrical quantities from 0 mV to 20 mV · CMC 15·10⁻⁶·U + 0,05 µV from 20 mV to 200 mV · CMC 5,0·10⁻⁶·U from 200 mV to 2 V · CMC 2,6·10⁻⁶·U from 2 V to 20 V · CMC 2,1·10⁻⁶·U od 10 V do 10 V · CMC 1,5 µV od 20 V do 1 100 V · CMC 2,9·10⁻⁶·U CMC for the field of measured quantity: Electrical quantities |
Direct comparison with a calibrator or direct measurement by a multimeter | 611-MP-C097, 611-MP-C098 | |
| 43 | AC voltage / AC voltage sources and meters | Calibration – electrical quantities 10 Hz to 75 kHz — 0,9 mV to 2 mV · CMC 0,20 % 75 kHz to 400 kHz — 0,9 mV to 2 mV · CMC 0,31 % 400 kHz to 750 kHz — 0,9 mV to 2 mV · CMC 0,33 % 750 kHz to 1 MHz — 0,9 mV to 2 mV · CMC 0,35 % 10 Hz to 25 kHz — 2 mV to 20 mV · CMC 360·10⁻⁶·U 25 kHz to 75 kHz — 2 mV to 20 mV · CMC 330·10⁻⁶·U 75 kHz to 200 kHz — 2 mV to 20 mV · CMC 530·10⁻⁶·U 200 kHz to 400 kHz — 2 mV to 20 mV · CMC 710·10⁻⁶·U 400 kHz to 750 kHz — 2 mV to 20 mV · CMC 790·10⁻⁶·U 750 kHz to 1 MHz — 2 mV to 20 mV · CMC 1100·10⁻⁶·U 10 Hz to 25 kHz — 20 mV to 200 mV · CMC 98·10⁻⁶·U 25 kHz to 75 kHz — 20 mV to 200 mV · CMC 190·10⁻⁶·U 75 kHz to 200 kHz — 20 mV to 200 mV · CMC 370·10⁻⁶·U 200 kHz to 400 kHz — 20 mV to 200 mV · CMC 590·10⁻⁶·U 400 kHz to 750 kHz — 20 mV to 200 mV · CMC 650·10⁻⁶·U 750 kHz to 1 MHz — 20 mV to 200 mV · CMC 1000·10⁻⁶·U 10 Hz to 35 Hz — 200 mV to 2 V · CMC 37·10⁻⁶·U 35 Hz to 40 kHz — 200 mV to 2 V · CMC 26·10⁻⁶·U 40 kHz to 75 kHz — 200 mV to 2 V · CMC 37·10⁻⁶·U 75 kHz to 200 kHz — 200 mV to 2 V · CMC 48·10⁻⁶·U 200 kHz to 400 kHz — 200 mV to 2 V · CMC 120·10⁻⁶·U 400 kHz to 750 kHz — 200 mV to 2 V · CMC 230·10⁻⁶·U 750 kHz to 1 MHz — 200 mV to 2 V · CMC 590·10⁻⁶·U 10 Hz to 35 Hz — 2 V to 20 V · CMC 37·10⁻⁶·U 35 Hz to 40 kHz — 2 V to 20 V · CMC 26·10⁻⁶·U 40 kHz to 75 kHz — 2 V to 20 V · CMC 33·10⁻⁶·U 75 kHz to 200 kHz — 2 V to 20 V · CMC 40·10⁻⁶·U 200 kHz to 400 kHz — 2 V to 20 V · CMC 110·10⁻⁶·U 400 kHz to 750 kHz — 2 V to 20 V · CMC 210·10⁻⁶·U 750 kHz to 1 MHz — 2 V to 20 V · CMC 560·10⁻⁶·U 10 Hz to 35 Hz — 20 V to 200 V · CMC 42·10⁻⁶·U 35 Hz to 175 Hz — 20 V to 200 V · CMC 37·10⁻⁶·U 175 Hz to 40 kHz — 20 V to 200 V · CMC 28·10⁻⁶·U 40 kHz to 75 kHz — 20 V to 200 V · CMC 40·10⁻⁶·U 75 kHz to 150 kHz — 20 V to 200 V · CMC 71·10⁻⁶·U 150 kHz to 200 kHz — 20 V to 200 V · CMC 240·10⁻⁶·U 10 Hz to 5 kHz — 200 V to 1 100 V · CMC 40·10⁻⁶·U 5 kHz to 25 kHz — 200 V to 1 100 V · CMC 45·10⁻⁶·U 25 kHz to 40 kHz — 200 V to 1 100 V · CMC 76·10⁻⁶·U 40 kHz to 750 kHz — 200 V to 1 100 V · CMC 120·10⁻⁶·U Generation only up to 750 V; 75 kHz to 100 kHz — 200 V to 1 100 V · CMC 350·10⁻⁶·U CMC for the field of measured quantity: Electrical quantities |
Direct comparison with a calibrator or direct measurement by a multimeter | 611-MP-C097 611-MP-C098 | |
| 44 | DC current / DC current generators | Calibration – electrical quantities from 0 µA to 1 µA · CMC 0,10 nA from 1 µA to 100 µA · CMC 21·10⁻⁶·I from 100 µA to 200 µA · CMC 12·10⁻⁶·I od 200 µA do 2 A · CMC 6,0·10⁻⁶·I from 2 A to 20 A · CMC 15·10⁻⁶·I from 20 A to 100 A · CMC 20·10⁻⁶·I CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a multimeter or indirect measurement using a current shunt | 611-MP-C097 | |
| 45 | DC current / DC current meters | Calibration – electrical quantities from 0 µA to 1 µA · CMC 0,10 nA from 1 µA to 100 µA · CMC 21·10⁻⁶·I from 100 µA to 200 µA · CMC 15·10⁻⁶·I from 200 µA to 20 mA · CMC 6,0·10⁻⁶·I from 20 mA to 200 mA · CMC 8,0·10⁻⁶·I from 200 mA to 2 A · CMC 15·10⁻⁶·I od 2 A do 100 A · CMC 30·10⁻⁶·I CMC for the field of measured quantity: Electrical quantities |
Direct generation by a calibrator | 611-MP-C098 | |
| 46 | AC current / AC current generators | Calibration – electrical quantities 10 Hz to 20 Hz — 9 µA to 2 mA · CMC 100·10⁻⁶·I 20 Hz to 40 Hz — 9 µA to 2 mA · CMC 90·10⁻⁶·I 40 Hz to 5 kHz — 9 µA to 2 mA · CMC 70·10⁻⁶·I 5 kHz to 10 kHz — 9 µA to 2 mA · CMC 80·10⁻⁶·I 10 kHz to 30 kHz — 9 µA to 2 mA · CMC 300·10⁻⁶·I 10 Hz to 20 Hz — 2 mA to 20 mA · CMC 90·10⁻⁶·I 20 Hz to 40 Hz — 2 mA to 20 mA · CMC 75·10⁻⁶·I 40 Hz to 1 kHz — 2 mA to 20 mA · CMC 65·10⁻⁶·I 1 kHz to 10 kHz — 2 mA to 20 mA · CMC 70·10⁻⁶·I 10 kHz to 30 kHz — 2 mA to 20 mA · CMC 300·10⁻⁶·I 10 Hz to 20 Hz — 20 mA to 200 mA · CMC 80·10⁻⁶·I 20 Hz to 1 kHz — 20 mA to 200 mA · CMC 65·10⁻⁶·I 1 kHz to 5 kHz — 20 mA to 200 mA · CMC 70·10⁻⁶·I 5 kHz to 10 kHz — 20 mA to 200 mA · CMC 80·10⁻⁶·I 10 kHz to 30 kHz — 20 mA to 200 mA · CMC 300·10⁻⁶·I 10 Hz to 20 Hz — 200 mA to 2 A · CMC 120·10⁻⁶·I 20 Hz to 40 Hz — 200 mA to 2 A · CMC 100·10⁻⁶·I 40 Hz to 1 kHz — 200 mA to 2 A · CMC 90·10⁻⁶·I 1 kHz to 5 kHz — 200 mA to 2 A · CMC 100·10⁻⁶·I 5 kHz to 10 kHz — 200 mA to 2 A · CMC 120·10⁻⁶·I 10 kHz to 30 kHz — 200 mA to 2 A · CMC 500·10⁻⁶·I 10 Hz to 20 Hz — 2 A to 20 A · CMC 180·10⁻⁶·I 20 Hz to 40 Hz — 2 A to 20 A · CMC 160·10⁻⁶·I 40 Hz to 1 kHz — 2 A to 20 A · CMC 110·10⁻⁶·I 1 kHz to 5 kHz — 2 A to 20 A · CMC 140·10⁻⁶·I 5 kHz to 10 kHz — 2 A to 20 A · CMC 160·10⁻⁶·I 10 Hz to 20 Hz — 20 A to 100 A · CMC 250·10⁻⁶·I 20 Hz to 40 Hz — 20 A to 100 A · CMC 160·10⁻⁶·I 40 Hz to 1 kHz — 20 A to 100 A · CMC 120·10⁻⁶·I 1 kHz to 5 kHz — 20 A to 100 A · CMC 150·10⁻⁶·I 5 kHz to 10 kHz — 20 A to 100 A · CMC 200·10⁻⁶·I CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a multimeter or indirect measurement using current shunts | 611-MP-C097 | |
| 47 | AC current / AC current meters | Calibration – electrical quantities 10 Hz to 35 Hz — 9 µA to 200 µA · CMC 130·10⁻⁶·I 35 Hz to 1 kHz — 9 µA to 200 µA · CMC 100·10⁻⁶·I 1 kHz to 5 kHz — 9 µA to 200 µA · CMC 160·10⁻⁶·I 5 kHz to 10 kHz — 9 µA to 200 µA · CMC 800·10⁻⁶·I 10 kHz to 30 kHz — 9 µA to 200 µA · CMC 2 000·10⁻⁶·I 10 Hz to 35 Hz — 200 µA to 2 mA · CMC 120·10⁻⁶·I 35 Hz to 1 kHz — 200 µA to 2 mA · CMC 90·10⁻⁶·I 1 kHz to 10 kHz — 200 µA to 2 mA · CMC 140·10⁻⁶·I 10 kHz to 30 kHz — 200 µA to 2 mA · CMC 700·10⁻⁶·I 10 Hz to 35 Hz — 2 mA to 200 mA · CMC 120·10⁻⁶·I 35 Hz to 1 kHz — 2 mA to 200 mA · CMC 75·10⁻⁶·I 1 kHz to 5 kHz — 2 mA to 200 mA · CMC 130·10⁻⁶·I 5 kHz to 10 kHz — 2 mA to 200 mA · CMC 140·10⁻⁶·I 10 kHz to 30 kHz — 2 mA to 200 mA · CMC 700·10⁻⁶·I 10 Hz to 35 Hz — 200 mA to 2 A · CMC 170·10⁻⁶·I 35 Hz to 1 kHz — 200 mA to 2 A · CMC 120·10⁻⁶·I 1 kHz to 10 kHz — 200 mA to 2 A · CMC 220·10⁻⁶·I 10 Hz to 35 Hz — 2 A to 20 A · CMC 310·10⁻⁶·I 35 Hz to 1 kHz — 2 A to 20 A · CMC 200·10⁻⁶·I 1 kHz to 5 kHz — 2 A to 20 A · CMC 300·10⁻⁶·I 5 kHz to 10 kHz — 2 A to 20 A · CMC 690·10⁻⁶·I 10 Hz to 35 Hz — 20 A to 100 A · CMC 350·10⁻⁶·I 35 Hz to 1 kHz — 20 A to 100 A · CMC 200·10⁻⁶·I 1 kHz to 5 kHz — 20 A to 100 A · CMC 300·10⁻⁶·I 5 kHz to 10 kHz — 20 A to 100 A · CMC 950·10⁻⁶·I CMC for the field of measured quantity: Electrical quantities |
Direct generation by a calibrator | 611-MP-C098 | |
| 48 | DC resistance / DC resistance standards and resistance meters | Calibration – electrical quantities 100 µΩ · CMC 0,72 nΩ 1 mΩ · CMC 3,5 nΩ 10 mΩ · CMC 26 nΩ 20 mΩ · CMC 44 nΩ 100 mΩ · CMC 86 nΩ 1 Ω · CMC 0,76 µΩ 10 Ω · CMC 7,1 µΩ 25 Ω · CMC 16 µΩ 100 Ω · CMC 35 µΩ 1 kΩ · CMC 0,35 mΩ 10 kΩ · CMC 3,8 mΩ 100 kΩ · CMC 59 mΩ 1 MΩ · CMC 4,0 Ω 10 MΩ · CMC 70 Ω 100 MΩ · CMC 160 Ω 1 GΩ · CMC 100 kΩ 10 GΩ · CMC 5,0 MΩ 100 GΩ · CMC 25 MΩ 1 TΩ · CMC 200 MΩ CMC for the field of measured quantity: Electrical quantities |
Comparison by the ratio method – measuring voltage drops at a constant measuring current, or direct measurement of the standard resistor | 131-MP-C003, 131-MP-C005, 611-MP-C097, 611-MP-C098 | |
| 49 | DC resistance / DC resistance standards and resistance meters | Calibration – electrical quantities od 0 µΩ do 100 µΩ · CMC 3,5·10⁻⁶·R + 0,5 nΩ od 100 µΩ do 200 µΩ · CMC 7,2·10⁻⁶·R od 200 µΩ do 1 mΩ · CMC 6,0·10⁻⁶·R od 1 mΩ do 2 mΩ · CMC 3,5·10⁻⁶·R od 2 mΩ do 10 mΩ · CMC 5,6·10⁻⁶·R od 10 mΩ do 20 mΩ · CMC 2,6·10⁻⁶·R od 20 mΩ do 100 mΩ · CMC 1,6·10⁻⁶·R from 100 mΩ to 200 mΩ · CMC 0,86·10⁻⁶·R from 200 mΩ to 1 Ω · CMC 1,6·10⁻⁶·R from 1 Ω to 2 Ω · CMC 0,73·10⁻⁶·R od 2 Ω do 10 Ω · CMC 1,6·10⁻⁶·R from 10 Ω to 20 Ω · CMC 0,71·10⁻⁶·R od 20 Ω do 100 Ω · CMC 1,2·10⁻⁶·R od 100 Ω do 200 Ω · CMC 0,35·10⁻⁶·R od 200 Ω do 1 kΩ · CMC 0,93·10⁻⁶·R from 1 kΩ to 2 kΩ · CMC 0,35·10⁻⁶·R from 2 kΩ to 10 kΩ · CMC 1,2·10⁻⁶·R od 10 kΩ do 20 kΩ · CMC 0,38·10⁻⁶·R from 20 kΩ to 100 kΩ · CMC 0,86·10⁻⁶·R from 100 kΩ to 200 kΩ · CMC 0,59·10⁻⁶·R from 200 kΩ to 1 MΩ · CMC 4,1·10⁻⁶·R from 1 MΩ to 2 MΩ · CMC 4,0·10⁻⁶·R od 2 MΩ do 10 MΩ · CMC 7,4·10⁻⁶·R od 10 MΩ do 20 MΩ · CMC 7,0·10⁻⁶·R from 20 MΩ to 200 MΩ · CMC 16·10⁻⁶·R from 200 MΩ to 1 GΩ · CMC 520·10⁻⁶·R from 1 GΩ to 2 GΩ · CMC 120·10⁻⁶·R from 2 GΩ to 10 GΩ · CMC 0,52 % from 10 GΩ to 20 GΩ · CMC 0,12 % CMC for the field of measured quantity: Electrical quantities |
Comparison by the ratio method – measuring voltage drops at a constant measuring current, or direct measurement of the standard resistor | 131-MP-C003, 131-MP-C005, 611-MP-C097, 611-MP-C098 | |
| 50 | Resistance ratio / Thermometric bridges 0 Hz to 400 Hz | Calibration – electrical quantities 0 to 4 · CMC 1,6·10⁻⁸ CMC for the field of measured quantity: Electrical quantities |
Measurement by a set of standard resistors or a simulated resistance ratio generated by an inductive divider | 611-MP-C045 | |
| 51 | Digital electrical inspection instruments and related standards / insulation resistance | Calibration – electrical quantities od 10 kΩ do 10 MΩ · CMC 0,0012 % from 10 MΩ to 100 MΩ · CMC 0,0020 % from 100 MΩ to 1 GΩ · CMC 0,010 % from 1 GΩ to 10 GΩ · CMC 0,025 % from 10 GΩ to 100 GΩ · CMC 0,050 % from 100 GΩ to 1 TΩ · CMC 0,002·R² + 0,001·R (Pozn. 5) 100 MΩ · CMC 0,0017 % 1 GΩ · CMC 0,0030 % 10 GΩ · CMC 0,010 % CMC for the field of measured quantity: Electrical quantities |
Indirect measurement using a voltage calibrator, reference resistor and voltmeter | 131-MP-C006 | |
| 52 | Digital electrical inspection instruments and related standards / insulation resistance | Calibration – electrical quantities od 10 kΩ do 1 GΩ · CMC 0,020 % from 1 GΩ to 10 GΩ · CMC 1,0 % from 10 GΩ to 100 GΩ · CMC 1,5 % from 100 GΩ to 1 TΩ · CMC 2,5 % from 1 TΩ to 10 TΩ · CMC 4,0 % 100 MΩ · CMC 0,0030 % 1 GΩ · CMC 0,0050 % 10 GΩ · CMC 0,020 % 100 GΩ · CMC 0,10 % 1 TΩ · CMC 0,50 % CMC for the field of measured quantity: Electrical quantities |
Direct generation of resistance by an inspection instrument calibrator, resistance decade or resistance standards | 131-MP-C006 | |
| 53 | Digital electrical inspection instruments and related standards / protective loop, line impedance and earth loop | Calibration – electrical quantities 25 mΩ · CMC 5,0 mΩ 50 mΩ · CMC 5,0 mΩ 100 mΩ · CMC 5,0 mΩ 330 mΩ · CMC 7,0 mΩ 500 mΩ · CMC 8,0 mΩ 1 Ω · CMC 10 mΩ 1,8 Ω · CMC 18 mΩ 5 Ω · CMC 30 mΩ 10 Ω · CMC 60 mΩ 18 Ω · CMC 100 mΩ 50 Ω · CMC 300 mΩ 100 Ω · CMC 500 mΩ 180 Ω · CMC 1,0 Ω 500 Ω · CMC 2,5 Ω 1 kΩ · CMC 5,0 Ω 1,8 kΩ · CMC 10 Ω CMC for the field of measured quantity: Electrical quantities |
Direct generation of resistance by an inspection instrument calibrator, resistance decade or resistance standards | 131-MP-C006 | |
| 54 | Digital electrical inspection instruments and related standards / tripping current of residual current devices | Calibration – electrical quantities 50 Hz — 3 mA to 3 A · CMC 0,20 % 50 Hz — 3 mA to 3 A · CMC 1,0 % CMC for the field of measured quantity: Electrical quantities |
Simulation of a residual current device and direct measurement of the tripping current by an inspection instrument calibrator | 131-MP-C006 | |
| 55 | Digital electrical inspection instruments and related standards / tripping time of residual current devices | Calibration – electrical quantities 50 Hz — 10 ms to 5 s · CMC 0,05 ms 50 Hz — 10 ms to 5 s · CMC 0,020 % + 0,25 ms CMC for the field of measured quantity: Electrical quantities |
Simulation of a residual current device and direct measurement of the tripping time by an inspection instrument calibrator | 131-MP-C006 | |
| 56 | Digital electrical inspection instruments and related standards / passive leakage current | Calibration – electrical quantities 50 Hz — 0,1 mA to 30 mA · CMC 0,30 % + 2 µA CMC for the field of measured quantity: Electrical quantities |
Direct comparison with an inspection instrument calibrator | 131-MP-C006 | |
| 57 | Digital electrical inspection instruments and related standards / differential leakage current | Calibration – electrical quantities 50 Hz — 0,1 mA to 30 mA · CMC 0,30 % + 2 µA CMC for the field of measured quantity: Electrical quantities |
Direct comparison with an inspection instrument calibrator | 131-MP-C006 | |
| 58 | Digital electrical inspection instruments and related standards / substitute leakage current | Calibration – electrical quantities 50 Hz — 0,1 mA to 30 mA · CMC 0,30 % + 2 µA CMC for the field of measured quantity: Electrical quantities |
Direct comparison with an inspection instrument calibrator | 131-MP-C006 | |
| 59 | Digital electrical inspection instruments and related standards / active leakage current | Calibration – electrical quantities 50 Hz — 0,1 mA to 30 mA · CMC 0,30 % + 1 µA DC + 20 Hz to 400 Hz — 0,1 mA to 300 mA · CMC 0,20 % CMC for the field of measured quantity: Electrical quantities |
Direct comparison with an inspection instrument calibrator | 131-MP-C006 | |
| 60 | Digital electrical inspection instruments and related standards / DC voltage | Calibration – electrical quantities 0 V to 10 kV · CMC 0,30 % + 5 V CMC for the field of measured quantity: Electrical quantities |
Direct measurement of high voltage using an inspection instrument calibrator or a voltmeter and voltage probe | 131-MP-C006 | |
| 61 | Digital electrical inspection instruments and related standards / AC voltage | Calibration – electrical quantities 50 Hz — 0 V to 10 kV · CMC 0,50 % + 5 V CMC for the field of measured quantity: Electrical quantities |
Direct measurement of high voltage using an inspection instrument calibrator or a voltmeter and voltage probe | 131-MP-C006 | |
| 62 | Digital electrical inspection instruments and related standards / DC current | Calibration – electrical quantities Current clamps — 1 A to 1 kA · CMC 0,80 % CMC for the field of measured quantity: Electrical quantities |
Current simulation by a calibrator and current coil | 131-MP-C006 | |
| 63 | Digital electrical inspection instruments and related standards / AC current | Calibration – electrical quantities Current clamps; 50 Hz — 1 A to 1 kA · CMC 0,50 % CMC for the field of measured quantity: Electrical quantities |
Current simulation by a calibrator and current coil | 131-MP-C006 | |
| 64 | Vertical deflection factor / oscilloscope | Calibration – electrical quantities 0 Hz — -222 V to 222 V · CMC 0,025 % + 25 µV 10 Hz to 10 kHz — 1 mV to 21 mV · CMC 0,1 % + 15 µV 10 Hz to 10 kHz — 21 mV to 556 mV · CMC 0,1 % + 1 µV 10 Hz to 10 kHz — 556 mV to 210 V · CMC 0,05 % + 1 µV CMC for the field of measured quantity: Electrical quantities |
Direct voltage generation by an oscilloscope calibrator | 113-MP-C008 | |
| 65 | Time base / oscilloscope | Calibration – electrical quantities 1 ns to 50 s · CMC 0,25·10⁻⁶ CMC for the field of measured quantity: Electrical quantities |
Direct generation by an oscilloscope calibrator | 113-MP-C008 | |
| 66 | Bandwidth / oscilloscope | Calibration – electrical quantities drop -3 dB — 0,1 Hz to 300 MHz · CMC 4 % drop -3 dB — 300 MHz to 550 MHz · CMC 5 % drop -3 dB — 550 MHz to 1,1 GHz · CMC 7 % drop -3 dB — 1,1 GHz to 3,2 GHz · CMC 8 % CMC for the field of measured quantity: Electrical quantities |
Measurement using an oscilloscope calibrator | 113-MP-C008 | |
| 67 | Relative drop of the frequency response / oscilloscope | Calibration – electrical quantities 0,1 Hz to 300 MHz — -6 dB to 6 dB · CMC 0,18 dB 300 MHz to 550 MHz — -6 dB to 6 dB · CMC 0,22 dB 550 MHz to 1,1 GHz — -6 dB to 6 dB · CMC 0,31 dB 1,1 GHz to 3,2 GHz — -6 dB to 6 dB · CMC 0,35 dB CMC for the field of measured quantity: Electrical quantities |
Measurement using an oscilloscope calibrator | 113-MP-C008 | |
| 68 | Rise time / oscilloscope | Calibration – electrical quantities 300 ps to 1 s · CMC 12 ps CMC for the field of measured quantity: Electrical quantities |
Measurement of the calibrator signal by an oscilloscope and correction | 113-MP-C008 | |
| 69 | Input resistance / oscilloscopes, counters etc. | Calibration – electrical quantities 800 kΩ to 1,2 MΩ · CMC 0,1 % 40 Ω to 90 Ω · CMC 0,1 % CMC for the field of measured quantity: Electrical quantities |
Measurement by an oscilloscope calibrator | 113-MP-C008 | |
| 70 | Voltage division ratio / oscilloscope probes | Calibration – electrical quantities Up to 222 V; 0 Hz to 10 kHz — 0,9 : 1 to 1 100 : 1 · CMC 0,5 % CMC for the field of measured quantity: Electrical quantities |
Direct voltage generation by an oscilloscope calibrator | 113-MP-C008 | |
| 71 | RF power calibration factor / power sensors | Calibration – electrical quantities 0 GHz to 1 GHz — 0,05 to 1,1 · CMC 0,9 % 1 GHz to 18 GHz — 0,05 to 1,1 · CMC 1,5 % 18 GHz to 40 GHz — 0,05 to 1,1 · CMC 2,0 % 40 GHz to 50 GHz — 0,05 to 1,1 · CMC 3,0 % CMC for the field of measured quantity: Electrical quantities |
Direct comparison of the readings of the standard and the calibrated instrument | 113-MP-C014 | |
| 72 | RF power level L / level meters, | Calibration – electrical quantities 9 kHz to 2,5 GHz — 44 dB(mW) to 55 dB(mW) · CMC 0,12 dB 9 kHz to 6 GHz — 20 dB(mW) to 44 dB(mW) · CMC 0,09 dB 6 GHz to 18 GHz — 20 dB(mW) to 44 dB(mW) · CMC 0,14 dB 9 kHz to 1 GHz — 10 dB(mW) to 20 dB(mW) · CMC 0,06 dB 1 GHz to 10 GHz — 10 dB(mW) to 20 dB(mW) · CMC 0,07 dB 10 GHz to 18 GHz — 10 dB(mW) to 20 dB(mW) · CMC 0,1 dB 18 GHz to 40 GHz — 10 dB(mW) to 20 dB(mW) · CMC 0,13 dB 40 GHz to 50 GHz — 10 dB(mW) to 20 dB(mW) · CMC 0,15 dB 9 kHz to 10 GHz — -10 dB(mW) to 10 dB(mW) · CMC 0,05 dB 10 GHz to 18 GHz — -10 dB(mW) to 10 dB(mW) · CMC 0,09 dB 18 GHz to 40 GHz — -10 dB(mW) to 10 dB(mW) · CMC 0,13 dB 40 GHz to 50 GHz — -10 dB(mW) to 10 dB(mW) · CMC 0,15 dB 9 kHz to 1 GHz — -30 dB(mW) to -10 dB(mW) · CMC 0,06 dB 1 GHz to 10 GHz — -30 dB(mW) to -10 dB(mW) · CMC 0,07 dB 10 GHz to 18 GHz — -30 dB(mW) to -10 dB(mW) · CMC 0,1 dB 18 GHz to 40 GHz — -30 dB(mW) to -10 dB(mW) · CMC 0,13 dB 40 GHz to 50 GHz — -30 dB(mW) to -10 dB(mW) · CMC 0,15 dB 9 kHz to 1 GHz — -60 dB(mW) to -30 dB(mW) · CMC 0,07 dB 1 GHz to 10 GHz — -60 dB(mW) to -30 dB(mW) · CMC 0,09 dB 10 GHz to 18 GHz — -60 dB(mW) to -30 dB(mW) · CMC 0,1 dB 18 GHz to 40 GHz — -60 dB(mW) to -30 dB(mW) · CMC -0,001·(L+30) + 0,13 dB 40 GHz to 50 GHz — -60 dB(mW) to -30 dB(mW) · CMC -0,001·(L+30) + 0,15 dB 0,1 MHz to 1 GHz — -100 dB(mW) to -60 dB(mW) · CMC -0,001·(L+60) + 0,07 dB 1 GHz to 10 GHz — -100 dB(mW) to -60 dB(mW) · CMC -0,001·(L+60) + 0,07 dB 10 GHz to 18 GHz — -100 dB(mW) to -60 dB(mW) · CMC -0,0015·(L+60) + 0,11 dB 18 GHz to 26,5 GHz — -100 dB(mW) to -60 dB(mW) · CMC -0,002·(L+60) + 0,15 dB CMC for the field of measured quantity: Electrical quantities |
Direct comparison of the readings of the standard and the calibrated instrument | 113-MP-C014 | |
| 73 | RF voltage at a defined point on a coaxial line / probes, transducers | Calibration – electrical quantities 0 GHz to 2 GHz — 1 mV to 2 V · CMC 1 % 0 GHz to 2 GHz — 2 V to 100 V · CMC 1,7 % CMC for the field of measured quantity: Electrical quantities |
Power measurement and conversions with vector corrections | 113-MP-C014 | |
| 74 | RF current at a defined point on a coaxial line / probes, transducers | Calibration – electrical quantities 0 GHz to 2 GHz — 20 µA to 40 mA · CMC 1 % 0 GHz to 2 GHz — 40 mA to 2 A · CMC 1,7 % CMC for the field of measured quantity: Electrical quantities |
Power measurement and conversions with vector corrections | 113-MP-C014 | |
| 75 | Level difference ΔL of power, voltage and current / amplifiers, attenuators, level meters, signal sources and other test equipment | Calibration – electrical quantities 9 kHz to 1 MHz — 0 dB to 65 dB · CMC 0,0006ΔL + 0,02 dB 9 kHz to 1 MHz — 65 dB to 75 dB · CMC 0,14 dB 9 kHz to 1 MHz — 75 dB to 85 dB · CMC 0,21 dB 1 MHz to 13,2 GHz — 0 dB to 85 dB · CMC 0,0006ΔL + 0,02 dB 1 MHz to 13,2 GHz — 85 dB to 95 dB · CMC 0,14 dB 1 MHz to 13,2 GHz — 95 dB to 105 dB · CMC 0,21 dB 1 MHz to 13,2 GHz — 105 dB to 110 dB · CMC 0,56 dB 13,2 GHz to 26,5 GHz — 0 dB to 75 dB · CMC 0,0006ΔL + 0,02 dB 13,2 GHz to 26,5 GHz — 75 dB to 85 dB · CMC 0,14 dB 13,2 GHz to 26,5 GHz — 85 dB to 95 dB · CMC 0,21 dB 13,2 GHz to 26,5 GHz — 95 dB to 100 dB · CMC 0,56 dB 26,5 GHz to 50 GHz — 0 dB to 40 dB · CMC 0,1 dB CMC for the field of measured quantity: Electrical quantities |
Measurement of power ratio | 113-MP-C014 | |
| 76 | Voltage / equipment used mainly in testing (EMC) | Calibration – electrical quantities 0 Hz — 0,5 mV to 1 000 V · CMC 0,1 % 10 Hz to 100 kHz — 1 mV to 100 V · CMC 0,15 % +3 µV 10 Hz to 100 kHz — 100 V to 500 V · CMC 0,32 % CMC for the field of measured quantity: Electrical quantities |
Measurement by a standard multimeter | 113-MP-C014 | |
| 77 | Voltage / ESD simulators | Calibration – electrical quantities 0 Hz — 500 V to 35 kV · CMC 2 % +5 V CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a standard HV voltmeter | 113-MP-C017 | |
| 78 | Current / test equipment (EMC) | Calibration – electrical quantities 0 Hz — 0,1 mA to 1 A · CMC 0,1 % CMC for the field of measured quantity: Electrical quantities |
Measurement by a standard multimeter | 113-MP-C014 | |
| 79 | Current / loop antenna excitation | Calibration – electrical quantities 40 Hz to 60 Hz — 1 A to 40 A · CMC 1,5 % 40 Hz to 60 Hz — 40 A to 400 A · CMC 1,8 % CMC for the field of measured quantity: Electrical quantities |
Measurement using a shunt | 113-MP-C017 | |
| 80 | Current / current probes, shunts | Calibration – electrical quantities 10 Hz to 5 kHz — 50 mA to 1,9999 A · CMC 0,5 % CMC for the field of measured quantity: Electrical quantities |
Measurement using a shunt | 113-MP-C017 | |
| 81 | Transfer impedance / current probes | Calibration – electrical quantities 10 Hz to 100 MHz — -65 dB (Ω) to +35 dB (Ω) · CMC 0,2 dB 100 MHz to 300 MHz — -65 dB (Ω) to +35 dB (Ω) · CMC 0,35 dB 300 MHz to 400 MHz — -65 dB (Ω) to +35 dB (Ω) · CMC 0,5 dB CMC for the field of measured quantity: Electrical quantities |
Generation of input current and measurement of output voltage | 113-MP-C017 | |
| 82 | Amplitude modulation depth m / signal sources, modulation meters | Calibration – electrical quantities fc: 100 kHz to 10 MHz; fmod: 50 Hz to 10 kHz — 5 % to 99 % · CMC 0,0075·m fc: 10 MHz to 3 GHz; fmod: 50 Hz to 100 kHz — 5 % to 20 % · CMC 0,025·m fc: 10 MHz to 3 GHz; fmod: 50 Hz to 100 kHz — 20 % to 99 % · CMC 0,005·m CMC for the field of measured quantity: Electrical quantities |
Measurement by a standard modulation analyzer, direct comparison with a standard | 113-MP-C014 | |
| 83 | Impedance / coupling networks | Calibration – electrical quantities 9 kHz to 400 MHz; Modulus — 3 Ω to 200 Ω · CMC 6 % 9 kHz to 400 MHz; Phase — 3 Ω to 200 Ω · CMC 4° CMC for the field of measured quantity: Electrical quantities |
Measurement by a vector network analyzer and conversions | 113-MP-C017 | |
| 84 | Reflection coefficient modulus r / equipment used mainly in testing (EMC) | Calibration – electrical quantities Connector BNC; 9 kHz to 1 GHz — 0 to 1 · CMC 0,015r² + 0,01 Connector BNC; 1 GHz to 2 GHz — 0 to 1 · CMC 0,025r² + 0,02 Connector BNC; 2 GHz to 3 GHz — 0 to 1 · CMC 0,035r² + 0,03 CMC for the field of measured quantity: Electrical quantities |
Measurement by a vector network analyzer | 113-MP-C017 | |
| 85 | Reflection coefficient modulus r / equipment used mainly in testing (EMC) | Calibration – electrical quantities Connector N; 5 kHz to 2 GHz — 0 to 1 · CMC 0,07r² + 0,015 Connector N; 2 GHz to 8 GHz — 0 to 1 · CMC 0,08r² + 0,02 Connector N; 8 GHz to 18 GHz — 0 to 1 · CMC 0,12r² + 0,03 CMC for the field of measured quantity: Electrical quantities |
Measurement with directional bridges or couplers | 113-MP-C017 | |
| 86 | Current / pulse generators, ESD simulators | Calibration – electrical quantities 1 A to 130 A · CMC 4 % CMC for the field of measured quantity: Electrical quantities |
Measurement using an oscilloscope with an ESD target | 113-MP-C017 | |
| 87 | Short-circuit current, peak value / pulse generators | Calibration – electrical quantities Rise time ˃ 0,2 µs — 1 A to 3 kA · CMC 4 % CMC for the field of measured quantity: Electrical quantities |
Measurement by an oscilloscope with a shunt or a current transformer | 113-MP-C017 | |
| 88 | Open-circuit voltage, peak value / pulse generators | Calibration – electrical quantities Rise time ˃ 0,2 µs — 20 V to 8 kV · CMC 3,5 % CMC for the field of measured quantity: Electrical quantities |
Measurement using an oscilloscope with an HV probe | 113-MP-C017 | |
| 89 | Voltage into a load of 2 Ω, 10 Ω, 20 Ω, 50 Ω, peak value / pulse generators | Calibration – electrical quantities Rise time ˃ 0,2 µs — 10 V to 1 kV · CMC 3,8 % CMC for the field of measured quantity: Electrical quantities |
Measurement using an oscilloscope with an HV differential probe | 113-MP-C017 | |
| 90 | Voltage, peak value / EFT / burst pulse generators, ultrasonic flaw detectors, | Calibration – electrical quantities Into a 50 Ω load — 10 V to 4 kV · CMC 3 % Into a 1 kΩ load — 200 V to 6 kV · CMC 4 % CMC for the field of measured quantity: Electrical quantities |
Measurement using an oscilloscope with an HV divider or attenuators | 113-MP-C017 | |
| 91 | Impulse area / pulse generators for calibration of EMI receivers, ČSN EN 55016-1-1 ed.4 | Calibration – electrical quantities 9 kHz to 150 kHz — 0,1 µVs to 30 µVs · CMC 2,8 % 150 kHz to 30 MHz — 0,01 µVs to 1 µVs · CMC 2,8 % 30 MHz to 1 GHz — 1 nVs to 100 nVs · CMC 3 % CMC for the field of measured quantity: Electrical quantities |
Measurement by an oscilloscope with attenuators and subsequent calculations and corrections | 113-MP-C017 | |
| 92 | AC current ratio / Current measuring transformers | Calibration – electrical quantities 05 A to 5 000 A/ 5 A and 1 A; 50 Hz — 0,1 to 5 000 · CMC 0,002 % CMC for the field of measured quantity: Electrical quantities |
Comparison with a measuring transformer | 817-MP-C701 | |
| 93 | Current phase displacement / Current measuring transformers | Calibration – electrical quantities 0 5 A to 5 000 A/ 5 A and 1 A; 50 Hz — -600 ′ to 600 ′ · CMC 0,07′ CMC for the field of measured quantity: Electrical quantities |
Comparison with a measuring transformer | 817-MP-C701 | |
| 94 | AC voltage ratio / Voltage measuring transformers | Calibration – electrical quantities 5 kV /100 V; 50 Hz — 50 · CMC 0,006 % 10 kV /100 V; 50 Hz — 100 · CMC 0,006 % 22 kV/100 V; 50 Hz — 220 · CMC 0,006 % CMC for the field of measured quantity: Electrical quantities |
Comparison with a measuring transformer | 817-MP-C701 | |
| 95 | AC voltage ratio / Voltage measuring transformers | Calibration – electrical quantities 100 V to 400 kV/5 V to 250 V; 50 Hz — 0,4 to 80 000 · CMC 0,007 % CMC for the field of measured quantity: Electrical quantities |
Comparison with an HV divider | 817-MP-C701 | |
| 96 | Voltage measuring transformers / Voltage phase displacement | Calibration – electrical quantities 5 kV; 10 kV and 22 kV/100 V; 50 Hz — -600 ′ to 600 ′ · CMC 0,21′ CMC for the field of measured quantity: Electrical quantities |
Comparison with a measuring transformer | 817-MP-C701 | |
| 97 | Voltage measuring transformers / Voltage phase displacement | Calibration – electrical quantities 100 V to 400 kV/5 V to 250 V; 50Hz — -600 ′ to 600 ′ · CMC 0,24′ CMC for the field of measured quantity: Electrical quantities |
Comparison with an HV divider | 817-MP-C701 | |
| 98 | Minimum input signal level / electronic counters | Calibration – electrical quantities 0 Hz to 500 MHz — 1 mV to 1 V · CMC 5 % + 1 mV CMC for the field of measured quantity: Electrical quantities |
Voltage generation by a calibrator or generator in combination with a level meter | 113-MP-C007 | |
| 99 | DC resistance / equipment used mainly in testing (EMC) | Calibration – electrical quantities 0,5 Ω to 1,2 MΩ · CMC 0,1 % + 0,01 Ω CMC for the field of measured quantity: Electrical quantities |
Measurement by a standard multimeter | 113-MP-C017 | |
| 100 | Transmission coefficient modulus T / equipment used mainly in testing (EMC) | Calibration – electrical quantities 9 kHz to 4,5 GHz — 0 dB to -10 dB · CMC 0,025 - 0,001·T dB 9 kHz to 4,5 GHz — -10 dB to -70 dB · CMC 0,035 - 0,0025·(T+10) dB 9 kHz to 4,5 GHz — -70 dB to -90 dB · CMC 0,185 - 0,015·(T+70) dB CMC for the field of measured quantity: Electrical quantities |
Measurement by a vector network analyzer | 113-MP-C017 | |
| 101 | Frequency / signal sources, frequency meters | Calibration – time and frequency quantities 0,01 Hz to 3 GHz · CMC 1·10⁻¹¹ CMC for the field of measured quantity: Time and frequency quantities |
Measurement by a standard counter, direct comparison with a standard, alternatively using frequency dividers | 113-MP-C007 | |
| 102 | Frequency / signal sources, frequency meters | Calibration – time and frequency quantities 3 GHz to 18 GHz · CMC 1·10⁻¹¹ 18 GHz to 46 GHz · CMC 3 Hz CMC for the field of measured quantity: Time and frequency quantities |
Measurement by a standard counter, direct comparison with a standard, alternatively using frequency dividers | 113-MP-C007 | |
| 103 | Period / signal sources, time interval meters | Calibration – time and frequency quantities from 5 ns to 10⁵ s · CMC 1·10⁻¹¹ CMC for the field of measured quantity: Time and frequency quantities |
Measurement by a standard counter, direct comparison with a standard | 113-MP-C007 | |
| 104 | Time interval / signal sources, time interval meters, | Calibration – time and frequency quantities 0 s to 10⁵ s · CMC (1,1·10⁻⁹ +1·10⁻¹¹ t) s CMC for the field of measured quantity: Time and frequency quantities |
Measurement by a counter | 113-MP-C007 | |
| 105 | Time interval / signal sources, time interval meters, | Calibration – time and frequency quantities 0 s to 10 s · CMC (10·10⁻¹² +2·10⁻³ t) s CMC for the field of measured quantity: Time and frequency quantities |
Measurement by an oscilloscope | 113-MP-C007 | |
| 106 | Simple pulse counting / pulse sources, pulse counters | Calibration – time and frequency quantities fmax= 50 MHz — 0 to 1·10⁷ · CMC 0 CMC for the field of measured quantity: Time and frequency quantities |
Measurement by a standard counter, direct comparison with a standard | 113-MP-C007 | |
| 107 | FM frequency deviation / signal sources, modulation meters | Calibration – time and frequency quantities fc=250 kHz to 10 MHz; fmod=20 Hz to 10 kHz; Δf/ fmod˃0,2 — 0,2 kHz to 40 kHz · CMC 1,5 % fc=250 kHz to 10 MHz; fmod=20 Hz to 10 kHz; Δf/ fmod˃1,2 — 0,2 kHz to 40 kHz · CMC 1 % fc=10 MHz to 6.6 GHz; fmod=50 Hz to 200 kHz; Δf/ fmod˃0,2 — 0,25 kHz to 400 kHz · CMC 1,5 % fc=10 MHz to 6.6 GHz; fmod=50 Hz to 200 kHz; Δf/ fmod˃0,45 — 0,25 kHz to 400 kHz · CMC 1 % CMC for the field of measured quantity: Time and frequency quantities |
Measurement by a standard modulation meter, direct comparison with a standard | 113-MP-C007 | |
| 108 | Time interval / mechanically operated stopwatches | Calibration – time and frequency quantities 0,1 s to 35 999,99 s · CMC 16 ms CMC for the field of measured quantity: Time and frequency quantities |
Direct comparison with a standard | 113-MP-C013 | |
| 109 | Relative frequency error of the time base / stopwatches with LCD | Calibration – time and frequency quantities -1·10⁻³ to 1·10⁻³ · CMC 3·10⁻⁷ CMC for the field of measured quantity: Time and frequency quantities |
Frequency measurement - capacitive coupling to the LCD | 113-MP-C013 | |
| 110 | Ethanol concentration / breath alcohol analyzers | Calibration – physicochemical quantities Gas phase — 0 mg/l to 1 400 mg/l · CMC od 0,006 mg/l do 0,028 mg/l CMC for the field of measured quantity: Physicochemical quantities |
Dry gas | 114-MP-C004, kap č. 5.3.1 | |
| 111 | Ethanol concentration / breath alcohol analyzers | Calibration – physicochemical quantities Gas phase — 0 mg/l to 0,480 mg/l · CMC od 0,008 mg/l od 0,013 mg/l CMC for the field of measured quantity: Physicochemical quantities |
Simulation method | 114-MP-C004, kap č. 5.3.2 | |
| Regional Inspectorate Liberec | |||||
| 112 | Strain gauges for mechanical testing of materials | Calibration – length from 0 mm to 25 mm · CMC 0,9 µm od 25 mm do 50 mm · CMC 1,3 µm od 50 mm do 1 000 mm · CMC 20 µm CMC for the field of measured quantity: Length |
ČSN EN ISO 9513 | 151-MP-C003 | |
| 113 | Strain gauges for mechanical testing of materials | Calibration – length from 0 mm to 10 mm · CMC 0,9 µm from 10 mm to 50 mm · CMC 1,3 µm od 50 mm do 1 000 mm · CMC 20 µm CMC for the field of measured quantity: Length |
ASTM E83 | 151-MP-C005 | |
| 114 | Gauge blocks | Calibration – length 2nd order — 0,1 mm to 1 000 mm · CMC (0,5L +0,05) µm 3rd order — 0,1 mm to 1 000 mm · CMC (1L +0,1) µm 4th order — 0,1 mm to 1 000 mm · CMC (2L +0,2) µm 5th order — 0,1 mm to 1 000 mm · CMC (5L +0,5) µm CMC for the field of measured quantity: Length |
Mechanical comparison with a standard using a comparator or length gauge | 614-MP-C033 (ČSN EN ISO 3650) | |
| 115 | Mechanical comparators of nominal length (0.3 to 100) mm | Calibration – length -0,01 mm to +0,01 mm · CMC 0,032 µm CMC for the field of measured quantity: Length |
Comparison using gauge blocks | 614-MP-C005 | |
| 116 | Micrometers | Calibration – length from 0 mm to 500 mm · CMC (5L +1,5) µm CMC for the field of measured quantity: Length |
Comparison with gauge blocks and gauges | 614-MP-C008 | |
| 117 | Calipers | Calibration – length 0 mm to 1 000 mm · CMC 20 µm CMC for the field of measured quantity: Length |
Comparison with gauge blocks, gauges and rings | 614-MP-C009 | |
| 118 | Length measuring instruments, meters and gauges | Calibration – length 0 mm to 1 000 mm · CMC (2L +0,2) µm CMC for the field of measured quantity: Length |
Direct measurement by a length gauge | 614-MP-C029 | |
| 119 | Machines with electronic measurement of cubic content of wooden logs | Calibration – length length — 0 m to 30 m · CMC 7 mm diameter — 5 cm to 100 m · CMC 0,2 mm CMC for the field of measured quantity: Length |
Comparison using an artefact measured by a standard or direct comparison with a standard | 411-MP-C003 | |
| 120 | Length sensors, thickness sensors, indicators | Calibration – length from 0 mm to 150 mm · CMC 0,2 µm CMC for the field of measured quantity: Length |
Comparison with parallel gauge blocks | 411-MP-C011 | |
| 121 | Autocollimators | Calibration – plane angle -4 000 ″ to 4 000 ″ · CMC Q[0,01; 2·10⁻⁵·φ; 6·10⁻⁹·φ²]″ CMC for the field of measured quantity: Plane angle |
Comparison with a small angle generator | 411-MP-C004 | |
| 122 | Levels, autocollimators, inclinometers | Calibration – plane angle from -180 ° to 180 ° · CMC 0,05″ CMC for the field of measured quantity: Plane angle |
Comparison with a rotary table or autocollimator | 411-MP-C004 | |
| 123 | Index heads and tables, goniometers, instruments for checking angular divisions, angle encoders, torque wrench angle sensors, built-in angle sensors, polygons, angle gauges, optical prisms | Calibration – plane angle from 0 ° to 360 ° · CMC 0,03″ CMC for the field of measured quantity: Plane angle |
Comparison with an optical polygon, autocollimator or rotary table | 411-MP-C006 | |
| 124 | Polygons, optical prisms, angle gauges | Calibration – plane angle from 0 ° to 360 ° · CMC 0,05″ CMC for the field of measured quantity: Plane angle |
Measurement using two autocollimators | 411-MP-C006 | |
| 125 | Angle gauges | Calibration – plane angle from 0 ° to 360 ° · CMC 60″ CMC for the field of measured quantity: Plane angle |
Comparison with angle gauges | 411-MP-C006 | |
| 126 | Mass of weights | Calibration – mass from 1 mg to 20 mg · CMC 0,001 0 mg 50 mg · CMC 0,001 3 mg 100 mg · CMC 0,001 6 mg 200 mg · CMC 0,002 0 mg 500 mg · CMC 0,002 6 mg 1 g · CMC 0,003 mg 2 g · CMC 0,004 mg 5 g · CMC 0,005 mg 10 g · CMC 0,006 mg 20 g · CMC 0,008 mg 50 g · CMC 0,010 mg 100 g · CMC 0,016 mg 200 g · CMC 0,030 mg 500 g · CMC 0,080 mg 1 kg · CMC 0,15 mg 2 kg · CMC 0,30 mg 5 kg · CMC 0,80 mg 10 kg · CMC 1,5 mg 20 kg · CMC 3,3 mg 50 kg · CMC 8 mg 100 kg · CMC 50 mg 200 kg · CMC 100 mg 500 kg · CMC 250 mg 1 000 kg · CMC 500 mg CMC for the field of measured quantity: Mass |
Comparison with a reference weight | 612-MP-C131 | |
| 127 | Balances with non-automatic and automatic function | Calibration – mass Weight E2 — 0 g to 20 kg · CMC 5·10⁻⁷ Weight F1 — 20 kg to 50 kg · CMC 1,6·10⁻⁶ Weight F2 — 50 kg to 600 kg · CMC 5·10⁻⁶ Weight M — 600 kg to 200 000 kg · CMC 1,6·10⁻⁵ CMC for the field of measured quantity: Mass |
Loading using a reference weight | 612-MP-C132 | |
| 128 | Force / force-proving instruments | Calibration – force, mechanical tests 0,02 N to 5 N · CMC 0,002 5 N to 2 MN · CMC 0,001 CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a force transmission standard (force-proving instrument) or by suspending weights | 811-MP-C111 | |
| 129 | Torque / torque measuring instruments | Calibration – force, mechanical tests 0,02 N·m to 0,2 N·m · CMC 0,001 0,2 N·m to 1 N·m · CMC 0,000 09 1 N·m to 100 N·m · CMC 0,000 08 100 N·m to 1 kN·m · CMC 0,000 1 1 kN·m to 10 kN·m · CMC 0,000 4 CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a standard torque measuring instrument, torque transmission standard (torque sensor) or using weights and torque arms | 811-MP-C102 | |
| 130 | Torque / torque wrenches | Calibration – force, mechanical tests 0,02 N·m to 3 kN·m · CMC 0,005 CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a torque transmission standard (torque sensor) (ČSN EN ISO 6789-1, ČSN EN ISO 6789-2) | 811-MP-C103 | |
| 131 | Torque / tightening tools and systems | Calibration – force, mechanical tests 0,25 N·m to 10 kN·m · CMC 0,005 CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a calibration device for torque wrenches, torque screwdrivers and tighteners | 411-MP-C103 | |
| 132 | Machines for mechanical testing of materials | Calibration – force, mechanical tests Pressure — 0,02 N to 5 MN · CMC 0,20 % Tension — 0,02 N to 2 MN · CMC 0,20 % CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a force transmission standard (force-proving instrument) or weights (ASTM E4, ČSN EN ISO 7500) | 151 MP-C001, 151-MP-C004 | |
| 133 | Machines for mechanical testing of materials | Calibration – force, mechanical tests Self-setting of the upper pressure plate — 200 kN to 2 MN · CMC 0,20 % CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN 12390-4 Annex A | 151-MP-C001 | |
| 134 | Hardness – hardness testers | Calibration – force, mechanical tests Rockwell A — 10 HRA to 100 HRA · CMC 0,38 HR Rockwell B — 10 HRBW to 110 HRBW · CMC 0,38 HR Rockwell C — 10 HRC to 80 HRC · CMC 0,38 HR Rockwell D — 10 HRD to 90 HRD · CMC 0,38 HR Rockwell E — 10 HREW to 110 HREW · CMC 0,38 HR Rockwell F — 10 HRFW to 100 HRFW · CMC 0,38 HR Rockwell G — 10 HRGW to 100 HRGW · CMC 0,38 HR Rockwell H — 10 HRHW to 110 HRHW · CMC 0,38 HR Rockwell K — 6 HRKW to 110 HRKW · CMC 0,38 HR Rockwell 15N — 10 HR15N to 100 HR15N · CMC 0,57 HR Rockwell 30N — 10 HR30N to 100 HR30N · CMC 0,57 HR Rockwell 45N — 10 HR45N to 90 HR45N · CMC 0,57 HR Rockwell 15T — 10 HR15TW to 100 HR15TW · CMC 0,57 HR Rockwell 30T — 10 HR30TW to 90 HR30TW · CMC 0,57 HR Rockwell 45T — 6 HR45TW to 80 HR45TW · CMC 0,57 HR CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN ISO 6508-2, ASTM E18 | 813-MP-C307 | |
| 135 | Hardness – hardness testers | Calibration – force, mechanical tests Vickers — 20 HV to 225 HV · CMC 0,32 % Vickers — 225 HV to 700 HV · CMC 0,32 % Vickers — 700 HV to 3 000 HV · CMC 0,32 % CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN ISO 6507-2, ASTM E384 | 813-MP-C307 | |
| 136 | Hardness – hardness testers | Calibration – force, mechanical tests Brinell — 20 HBW to 200 HBW · CMC 0,30 % Brinell — 200 HBW to 500 HBW · CMC 0,30 % Brinell — 500 HBW to 650 HBW · CMC 0,30 % CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN ISO 6506-2, ASTM E10 | 813-MP-C307 | |
| Regional Inspectorate Pardubice | |||||
| 137 | Strain gauges for mechanical testing of materials | Calibration – length from 0 mm to 25 mm · CMC 0,9 µm od 25 mm do 50 mm · CMC 1,3 µm od 50 mm do 1 000 mm · CMC 20 µm CMC for the field of measured quantity: Length |
ČSN EN ISO 9513 | 151-MP-C003 | |
| 138 | Strain gauges for mechanical testing of materials | Calibration – length from 0 mm to 10 mm · CMC 0,9 µm from 10 mm to 50 mm · CMC 1,3 µm od 50 mm do 1 000 mm · CMC 20 µm CMC for the field of measured quantity: Length |
ASTM E83 | 151-MP-C005 | |
| 139 | Gauge blocks | Calibration – length 2nd order — 0,1 mm to 1 000 mm · CMC (0,5L +0,05) µm 3rd order — 0,1 mm to 1 000 mm · CMC (1L +0,1) µm 4th order — 0,1 mm to 1 000 mm · CMC (2L +0,2) µm 5th order — 0,1 mm to 1 000 mm · CMC (5L +0,5) µm CMC for the field of measured quantity: Length |
Mechanical comparison with a standard using a comparator or length gauge | 614-MP-C033 (ČSN EN ISO 3650) | |
| 140 | Micrometers | Calibration – length from 0 mm to 500 mm · CMC (5L +1,5) µm CMC for the field of measured quantity: Length |
Comparison with gauge blocks and gauges | 614-MP-C008 | |
| 141 | Calipers | Calibration – length 0 mm to 1 000 mm · CMC 20 µm CMC for the field of measured quantity: Length |
Comparison with gauge blocks, gauges and rings | 614-MP-C009 | |
| 142 | Length measuring instruments, meters and gauges | Calibration – length 0 mm to 1 000 mm · CMC (2L +0,2) µm CMC for the field of measured quantity: Length |
Direct measurement by a length gauge | 614-MP-C029 | |
| 143 | Test sieves | Calibration – length 0,005 mm to 150 mm · CMC (4L +1,5) µm CMC for the field of measured quantity: Length |
Calibration on a 2D optical instrument, using slide gauge or limit gauges | 614-MP-C102 | |
| 144 | Gauges, standards, artefacts | Calibration – length from 0 mm to 600 mm · CMC (2,5L +1,2) µm CMC for the field of measured quantity: Length |
Calibration on a linear height gauge | 614-MP-C104 | |
| 145 | Tape measures, length and distance gauges | Calibration – length od 0,3 m do 30 m · CMC Q[100; 3L] µm from 0 m to 300 m · CMC Q[20; 20L] µm CMC for the field of measured quantity: Length |
Comparison using a tape measure, micrometer head | 815-MP-C510 | |
| 146 | Static volume/ Measuring vessels | Calibration – volume, flow rate Distilled water — 0,2 mL to 21 000 mL · CMC 0,01 % CMC for the field of measured quantity: Volume, flow rate |
Gravimetric method | 616-MP-C016 (ČSN EN ISO 4787, EURAMET cg-19) | |
| 147 | Static volume/ metal measuring vessels – limit, scaled, with a graduation mark | Calibration – volume, flow rate Distilled water / water — 2 L to 1 000 L · CMC 0,01 % CMC for the field of measured quantity: Volume, flow rate |
Gravimetric method | 615-MP-C151 (ČSN EN ISO 4787, EURAMET cg-19) | |
| 148 | Static volume / Piston volume meters | Calibration – volume, flow rate piston pipettes and syringes; Distilled water — 0,5 µL to 10 000 µL · CMC 0,13 % + 0,01 µL other piston gauges; Distilled water — 10 µL to 200 000 µL · CMC 0,04 % CMC for the field of measured quantity: Volume, flow rate |
Gravimetric method | 616-MP-C017 (ČSN EN ISO 8655-6 EURAMET cg-19) | |
| 149 | Static volume/ Stationary reservoirs and tanks | Calibration – volume, flow rate 5 dm³ to 500 dm³ · CMC 0,3 % CMC for the field of measured quantity: Volume, flow rate |
Volume method | 551-MP-C401 | |
| 150 | Static volume/ Stationary reservoirs and tanks | Calibration – volume, flow rate 20 dm³ to 100 m³ · CMC 0,3 % CMC for the field of measured quantity: Volume, flow rate |
Flow method | 551-MP-C401 | |
| 151 | Volume and velocity gas meters and flow meters for gas | Calibration – volume, flow rate 0,06 m³·h⁻¹ to 1 200 m³·h⁻¹ · CMC 0,25 % CMC for the field of measured quantity: Volume, flow rate |
Flow method | 512-MP-C103, kap. 5.1 | |
| 152 | Volume and velocity gas meters and flow meters for gas | Calibration – volume, flow rate 8 m³·h⁻¹ to 10 000 m³·h⁻¹ · CMC 0,19 % CMC for the field of measured quantity: Volume, flow rate |
Volume method | 512-MP-C103, kap. 5.2 | |
| 153 | Volume and velocity gas meters and flow meters for gas | Calibration – volume, flow rate 0,3 m³·h⁻¹ to 1 600 m³·h⁻¹ · CMC 0,20 % CMC for the field of measured quantity: Volume, flow rate |
Volume method | 512-MP-C103, kap. 5.3 | |
| 154 | Volume and velocity gas meters and flow meters for gas | Calibration – volume, flow rate Qmin to 0.1Qmax — 0,016 m³·h⁻¹ to 16 m³·h⁻¹ · CMC 0,65 % 0.1Qmax to Qmax — 0,016 m³·h⁻¹ to 16 m³·h⁻¹ · CMC 0,28 % CMC for the field of measured quantity: Volume, flow rate |
Volume method | 512-MP-C103, kap. 5.4 | |
| 155 | Volume and velocity gas meters and flow meters for gas | Calibration – volume, flow rate Qmin to 0.1Qmax — 0,02 m³·h⁻¹ to 160 m³·h⁻¹ · CMC 0,70 % 0.1Qmax to Qmax — 0,02 m³·h⁻¹ to 160 m³·h⁻¹ · CMC 0,50 % CMC for the field of measured quantity: Volume, flow rate |
Volume method | 512-MP-C103, kap. 5.5 | |
| 156 | Volume and velocity gas meters and flow meters for gas | Calibration – volume, flow rate 9,5 dm³·h⁻¹ to 760 dm³·h⁻¹ · CMC 0,16 % CMC for the field of measured quantity: Volume, flow rate |
Gravimetric method | 512-MP-C103 kap. 5.6 | |
| 157 | Volume and velocity gas meters and flow meters for gas | Calibration – volume, flow rate 0,5 m³·h⁻¹ to 280 m³·h⁻¹ · CMC 0,07 % CMC for the field of measured quantity: Volume, flow rate |
Volume method | 512-MP-C103 kap. 5.7 | |
| 158 | Float flow meters | Calibration – volume, flow rate 0,01 m³·h⁻¹ to 0,75 m³·h⁻¹ · CMC 1 % 0,75 m³·h⁻¹ to 1,3 m³·h⁻¹ · CMC 1,3 % 1,3 m³·h⁻¹ to 25 m³·h⁻¹ · CMC 1 % CMC for the field of measured quantity: Volume, flow rate |
Volume method | 512-MP-C104 | |
| 159 | Conversion number Z / Gas calculators | Calibration – volume, flow rate (–30 to +80) °C (0.8 to 135) bar — 0,8 to 275 · CMC 0,06 % CMC for the field of measured quantity: Volume, flow rate |
Temperature and pressure measurement by volume flow simulation | 512-MP-C105 | |
| 160 | Mass of weights | Calibration – mass from 1 mg to 20 mg · CMC 0,001 0 mg 50 mg · CMC 0,001 3 mg 100 mg · CMC 0,001 6 mg 200 mg · CMC 0,002 0 mg 500 mg · CMC 0,002 6 mg 1 g · CMC 0,003 mg 2 g · CMC 0,004 mg 5 g · CMC 0,005 mg 10 g · CMC 0,006 mg 20 g · CMC 0,008 mg 50 g · CMC 0,010 mg 100 g · CMC 0,016 mg 200 g · CMC 0,030 mg 500 g · CMC 0,080 mg 1 kg · CMC 0,15 mg 2 kg · CMC 0,30 mg 5 kg · CMC 0,80 mg 10 kg · CMC 1,5 mg 20 kg · CMC 3,3 mg 50 kg · CMC 8 mg 100 kg · CMC 50 mg 200 kg · CMC 100 mg 500 kg · CMC 250 mg 1 000 kg · CMC 500 mg CMC for the field of measured quantity: Mass |
Comparison with a reference weight | 612-MP-C131 | |
| 161 | Balances with non-automatic and automatic function | Calibration – mass Weight E2 — 0 g to 20 kg · CMC 5·10⁻⁷ Weight F1 — 20 kg to 50 kg · CMC 1,6·10⁻⁶ Weight F2 — 50 kg to 600 kg · CMC 5·10⁻⁶ Weight M — 600 kg to 200 000 kg · CMC 1,6·10⁻⁵ CMC for the field of measured quantity: Mass |
Loading using a reference weight | 612-MP-C132 | |
| 162 | Force / force-proving instruments | Calibration – force, mechanical tests 0,02 N to 5 N · CMC 0,002 5 N to 2 MN · CMC 0,001 CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a force transmission standard (force-proving instrument) or by suspending weights | 811-MP-C111 | |
| 163 | Machines for mechanical testing of materials | Calibration – force, mechanical tests Pressure — 0,02 N to 5 MN · CMC 0,20 % Tension — 0,02 N to 2 MN · CMC 0,20 % CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a force transmission standard (force-proving instrument) or weights (ASTM E4, ČSN EN ISO 7500) | 151 MP-C001, 151-MP-C004 | |
| 164 | Machines for mechanical testing of materials | Calibration – force, mechanical tests Self-setting of the upper pressure plate — 200 kN to 2 MN · CMC 0,20 % CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN 12390-4 Annex A | 151-MP-C001 | |
| 165 | Machines for mechanical testing of materials | Calibration – force, mechanical tests Increase in force — 0,01 kN/s to 150 kN/s · CMC 0,7 % CMC for the field of measured quantity: Force, mechanical tests |
Direct comparison with force and time standards, program AED PANEL32 | 151-MP-C006 | |
| 166 | Pendulum hammers for notch impact strength testing of materials | Calibration – force, mechanical tests 0,01 J to 2,5 kJ · CMC 0,02 % CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a force transmission standard (force-proving instrument) and length standard (ČSN EN ISO 148-2, ČSN EN ISO 13802, ASTM E23, BS 131-4) | 151-MP-C002 | |
| 167 | Deformation pressure gauges; digital pressure gauges; piston pressure gauges | Calibration – pressure, mechanical stress Absolute pressure; Gas — 1 Pa to 20 Pa · CMC 10 % Absolute pressure; Gas — 20 Pa to 5 000 Pa · CMC 3,5 Pa Absolute pressure; Gas — 5 kPa to 18 kPa · CMC 3,8 Pa Absolute pressure; Gas — 18 kPa to 2 000 kPa · CMC 9·10⁻⁵·p Absolute pressure; Gas — 2 MPa to 8 MPa · CMC 2,3·10⁻⁵·p + 56 Pa Overpressure; Gas — -100 kPa to -10 kPa · CMC 8,5·10⁻⁵·|pe| Overpressure; Gas — -10 kPa to -3,45 kPa · CMC 9,3·10⁻⁵·|pe| Overpressure; Gas — -3,45 kPa to -2 kPa · CMC 32 Pa Overpressure; Gas — -2 000 Pa to -6 Pa · CMC 1,3·10⁻⁴·|pe| + 48 Pa Overpressure; Gas — -6 Pa to +6 Pa · CMC 1,5 Pa Overpressure; Gas — 6 Pa to 2 000 Pa · CMC 1,3·10⁻⁴·pe + 48 Pa Overpressure; Gas — 2 kPa to 3,45 kPa · CMC 32 Pa Overpressure; Gas — 3,45 kPa to 10 kPa · CMC 9,3·10⁻⁵·pe Overpressure; Gas — 10 kPa to 100 kPa · CMC 8,5·10⁻⁵·pe Overpressure; Gas — 100 kPa to 345 kPa · CMC 8,8·10⁻⁵·pe Overpressure; Gas — 345 kPa to 2 000 kPa · CMC 9·10⁻⁵·pe + 1 Pa Overpressure; Gas — 2 MPa to 8 MPa · CMC 2,3·10⁻⁵·pe +55 Pa Absolute pressure p = pe + pamb; Liquid — 20 kPa to 600 kPa · CMC 49 Pa Absolute pressure p = pe + pamb; Liquid — 0,6 MPa to 40 MPa · CMC 8,2·10⁻⁵·pe + 10 Pa Absolute pressure p = pe + pamb; Liquid — 40 MPa to 100 MPa · CMC 8,7·10⁻⁵·pe + 10 Pa Absolute pressure p = pe + pamb; Liquid — 100 MPa to 120 MPa · CMC 1,2·10⁻⁴·pe + 10 Pa Overpressure; Liquid — 20 kPa to 600 kPa · CMC 48 Pa Overpressure; Liquid — 0,6 MPa to 40 MPa · CMC 8,2·10⁻⁵·pe Overpressure; Liquid — 40 MPa to 100 MPa · CMC 8,7·10⁻⁵·pe Overpressure; Liquid — 100 MPa to 120 MPa · CMC 1,2·10⁻⁴·pe CMC for the field of measured quantity: Pressure, mechanical stress |
Cross-floating method, determination of the effective area of the piston-cylinder unit and the mass of weights | 133-MP-C007, 601-MP-C046, 601-MP-C047 | |
| 168 | Glass thermometers | Calibration – temperature division < 0.1 °C — -90 °C to 100 °C · CMC 0,015 °C division < 0.1 °C — 100 °C to 150 °C · CMC 0,020 °C division < 0.1 °C — 150 °C to 210 °C · CMC 0,040 °C division < 0.1 °C — 210 °C to 360 °C · CMC 0,050 °C 0.1 °C ≤ division ≤ 1 °C — 360 °C to 420 °C · CMC 0,15 °C 0.1 °C ≤ division ≤ 1 °C — 420 °C to 550 °C · CMC 0,20 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in liquid bath | 133-MP-C001 | |
| 169 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature 0,01 °C · CMC 0,002 °C CMC for the field of measured quantity: Temperature |
Direct measurement at triple point of water | 133-MP-C004 | |
| 170 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature 660,32 °C · CMC 0,05 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor at a fixed point | 133-MP-C004 | |
| 171 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature -196 °C · CMC 0,03 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor near the boiling point of nitrogen | 133-MP-C004 | |
| 172 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature -196 °C to -100 °C · CMC 0,3 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor on the customer's equipment | 133-MP-C004 | |
| 173 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature od -100 °C do -90 °C · CMC 0,2 °C from 550 °C to 660 °C · CMC 0,09 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in a vertical furnace | 133-MP-C004 | |
| 174 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature from -90 °C to -80 °C · CMC 0,015 °C od -80 °C do 160 °C · CMC 0,01 °C od 160 °C do 300 °C · CMC 0,02 °C from 300 °C to 420 °C · CMC 0,03 °C od 420 °C do 550 °C · CMC 0,05 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in liquid bath | 133-MP-C004 | |
| 175 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature od 550 °C do 1 100 °C · CMC 0,7 °C from 1 100 °C to 1 300 °C · CMC 1,3 °C od 1 300 °C do 1 600 °C · CMC 1,8 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference temperature sensor in a furnace | 133-MP-C004 | |
| 176 | Moisture of solids / relative moisture meters | Calibration – physicochemical quantities Cereals and oilseeds — 4 % to 50 % · CMC 0,25 % CMC for the field of measured quantity: Physicochemical quantities |
Comparison with a reference determination | 511-MP-C001 | |
| 177 | Moisture of solids / relative moisture meters | Calibration – physicochemical quantities Plastics — 0,001 % to 20 % · CMC 0,005 % CMC for the field of measured quantity: Physicochemical quantities |
Comparison with a reference determination | 511-MP-C009 | |
| 178 | Moisture / absolute / relative moisture meters | Calibration – physicochemical quantities Solids — 4 % to 110 % · CMC 0,31 % CMC for the field of measured quantity: Physicochemical quantities |
Comparison with a reference determination | 511-MP-C003 | |
| 179 | Multiparameter analyzers | Calibration – physicochemical quantities relative moisture — 4 % to 50 % · CMC 0,27 % content of N-substances — 5 % to 40 % · CMC 0,30 % oil content — 10 % to 80 % · CMC 0,29 % Zeleny test — 10 ml to 75 ml · CMC 1,3 ml CMC for the field of measured quantity: Physicochemical quantities |
Comparison with a reference determination | 511-MP-C001 | |
| 180 | Refractive index / refractometers | Calibration – physicochemical quantities 1,3 to 1,7 · CMC 9·10⁻⁵ CMC for the field of measured quantity: Physicochemical quantities |
Comparison with a reference determination | 512-MP-C003 | |
| Regional Inspectorate Opava | |||||
| 181 | Strain gauges for mechanical testing of materials | Calibration – length from 0 mm to 25 mm · CMC 0,9 µm od 25 mm do 50 mm · CMC 1,3 µm od 50 mm do 1 000 mm · CMC 20 µm CMC for the field of measured quantity: Length |
ČSN EN ISO 9513 | 151-MP-C003 | |
| 182 | Strain gauges for mechanical testing of materials | Calibration – length from 0 mm to 10 mm · CMC 0,9 µm from 10 mm to 50 mm · CMC 1,3 µm od 50 mm do 1 000 mm · CMC 20 µm CMC for the field of measured quantity: Length |
ASTM E83 | 151-MP-C005 | |
| 183 | Static volume/ metal measuring vessels – limit, scaled, with a graduation mark | Calibration – volume, flow rate Distilled water / water — 2 L to 1 000 L · CMC 0,01 % CMC for the field of measured quantity: Volume, flow rate |
Gravimetric method | 615-MP-C151 (ČSN EN ISO 4787, EURAMET cg-19) | |
| 184 | Mass of weights | Calibration – mass from 1 mg to 20 mg · CMC 0,001 0 mg 50 mg · CMC 0,001 3 mg 100 mg · CMC 0,001 6 mg 200 mg · CMC 0,002 0 mg 500 mg · CMC 0,002 6 mg 1 g · CMC 0,003 mg 2 g · CMC 0,004 mg 5 g · CMC 0,005 mg 10 g · CMC 0,006 mg 20 g · CMC 0,008 mg 50 g · CMC 0,010 mg 100 g · CMC 0,016 mg 200 g · CMC 0,030 mg 500 g · CMC 0,080 mg 1 kg · CMC 0,15 mg 2 kg · CMC 0,30 mg 5 kg · CMC 0,80 mg 10 kg · CMC 1,5 mg 20 kg · CMC 3,3 mg 50 kg · CMC 8 mg 100 kg · CMC 50 mg 200 kg · CMC 100 mg 500 kg · CMC 250 mg 1 000 kg · CMC 500 mg CMC for the field of measured quantity: Mass |
Comparison with a reference weight | 612-MP-C131 | |
| 185 | Balances with non-automatic and automatic function | Calibration – mass Weight E2 — 0 g to 20 kg · CMC 5·10⁻⁷ Weight F1 — 20 kg to 50 kg · CMC 1,6·10⁻⁶ Weight F2 — 50 kg to 600 kg · CMC 5·10⁻⁶ Weight M — 600 kg to 200 000 kg · CMC 1,6·10⁻⁵ CMC for the field of measured quantity: Mass |
Loading using a reference weight | 612-MP-C132 | |
| 186 | Force / force-proving instruments | Calibration – force, mechanical tests 0,02 N to 5 N · CMC 0,002 5 N to 2 MN · CMC 0,001 CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a force transmission standard (force-proving instrument) or by suspending weights | 811-MP-C111 | |
| 187 | Machines for mechanical testing of materials | Calibration – force, mechanical tests Pressure — 0,02 N to 5 MN · CMC 0,20 % Tension — 0,02 N to 2 MN · CMC 0,20 % CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a force transmission standard (force-proving instrument) or weights (ASTM E4, ČSN EN ISO 7500) | 151 MP-C001, 151-MP-C004 | |
| 188 | Machines for mechanical testing of materials | Calibration – force, mechanical tests Self-setting of the upper pressure plate — 200 kN to 2 MN · CMC 0,20 % CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN 12390-4 Annex A | 151-MP-C001 | |
| 189 | Pendulum hammers for notch impact strength testing of materials | Calibration – force, mechanical tests 0,01 J to 2,5 kJ · CMC 0,02 % CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a force transmission standard (force-proving instrument) and length standard (ČSN EN ISO 148-2, ČSN EN ISO 13802, ASTM E23, BS 131-4) | 151-MP-C002 | |
| 190 | Hardness – hardness testers | Calibration – force, mechanical tests Rockwell A — 10 HRA to 100 HRA · CMC 0,38 HR Rockwell B — 10 HRBW to 110 HRBW · CMC 0,38 HR Rockwell C — 10 HRC to 80 HRC · CMC 0,38 HR Rockwell D — 10 HRD to 90 HRD · CMC 0,38 HR Rockwell E — 10 HREW to 110 HREW · CMC 0,38 HR Rockwell F — 10 HRFW to 100 HRFW · CMC 0,38 HR Rockwell G — 10 HRGW to 100 HRGW · CMC 0,38 HR Rockwell H — 10 HRHW to 110 HRHW · CMC 0,38 HR Rockwell K — 6 HRKW to 110 HRKW · CMC 0,38 HR Rockwell 15N — 10 HR15N to 100 HR15N · CMC 0,57 HR Rockwell 30N — 10 HR30N to 100 HR30N · CMC 0,57 HR Rockwell 45N — 10 HR45N to 90 HR45N · CMC 0,57 HR Rockwell 15T — 10 HR15TW to 100 HR15TW · CMC 0,57 HR Rockwell 30T — 10 HR30TW to 90 HR30TW · CMC 0,57 HR Rockwell 45T — 6 HR45TW to 80 HR45TW · CMC 0,57 HR CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN ISO 6508-2, ASTM E18 | 813-MP-C307 | |
| 191 | Hardness – hardness testers | Calibration – force, mechanical tests Vickers — 20 HV to 225 HV · CMC 0,32 % Vickers — 225 HV to 700 HV · CMC 0,32 % Vickers — 700 HV to 3 000 HV · CMC 0,32 % CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN ISO 6507-2, ASTM E384 | 813-MP-C307 | |
| 192 | Hardness – hardness testers | Calibration – force, mechanical tests Brinell — 20 HBW to 200 HBW · CMC 0,30 % Brinell — 200 HBW to 500 HBW · CMC 0,30 % Brinell — 500 HBW to 650 HBW · CMC 0,30 % CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN ISO 6506-2, ASTM E10 | 813-MP-C307 | |
| 193 | Deformation pressure gauges; digital pressure gauges; piston pressure gauges | Calibration – pressure, mechanical stress Absolute pressure; Gas — 1 Pa to 20 Pa · CMC 10 % Absolute pressure; Gas — 20 Pa to 5 000 Pa · CMC 3,5 Pa Absolute pressure; Gas — 5 kPa to 18 kPa · CMC 3,8 Pa Absolute pressure; Gas — 18 kPa to 2 000 kPa · CMC 9·10⁻⁵·p Absolute pressure; Gas — 2 MPa to 8 MPa · CMC 2,3·10⁻⁵·p + 56 Pa Overpressure; Gas — -100 kPa to -10 kPa · CMC 8,5·10⁻⁵·|pe| Overpressure; Gas — -10 kPa to -3,45 kPa · CMC 9,3·10⁻⁵·|pe| Overpressure; Gas — -3,45 kPa to -2 kPa · CMC 32 Pa Overpressure; Gas — -2 000 Pa to -6 Pa · CMC 1,3·10⁻⁴·|pe| + 48 Pa Overpressure; Gas — -6 Pa to +6 Pa · CMC 1,5 Pa Overpressure; Gas — 6 Pa to 2 000 Pa · CMC 1,3·10⁻⁴·pe + 48 Pa Overpressure; Gas — 2 kPa to 3,45 kPa · CMC 32 Pa Overpressure; Gas — 3,45 kPa to 10 kPa · CMC 9,3·10⁻⁵·pe Overpressure; Gas — 10 kPa to 100 kPa · CMC 8,5·10⁻⁵·pe Overpressure; Gas — 100 kPa to 345 kPa · CMC 8,8·10⁻⁵·pe Overpressure; Gas — 345 kPa to 2 000 kPa · CMC 9·10⁻⁵·pe + 1 Pa Overpressure; Gas — 2 MPa to 8 MPa · CMC 2,3·10⁻⁵·pe +55 Pa Absolute pressure p = pe + pamb; Liquid — 20 kPa to 600 kPa · CMC 49 Pa Absolute pressure p = pe + pamb; Liquid — 0,6 MPa to 40 MPa · CMC 8,2·10⁻⁵·pe + 10 Pa Absolute pressure p = pe + pamb; Liquid — 40 MPa to 100 MPa · CMC 8,7·10⁻⁵·pe + 10 Pa Absolute pressure p = pe + pamb; Liquid — 100 MPa to 120 MPa · CMC 1,2·10⁻⁴·pe + 10 Pa Overpressure; Liquid — 20 kPa to 600 kPa · CMC 48 Pa Overpressure; Liquid — 0,6 MPa to 40 MPa · CMC 8,2·10⁻⁵·pe Overpressure; Liquid — 40 MPa to 100 MPa · CMC 8,7·10⁻⁵·pe Overpressure; Liquid — 100 MPa to 120 MPa · CMC 1,2·10⁻⁴·pe CMC for the field of measured quantity: Pressure, mechanical stress |
Cross-floating method, determination of the effective area of the piston-cylinder unit and the mass of weights | 133-MP-C007, 601-MP-C046, 601-MP-C047 | |
| 194 | Ethanol concentration / breath alcohol analyzers | Calibration – physicochemical quantities Gas phase — 0 mg/l to 1 400 mg/l · CMC od 0,006 mg/l do 0,028 mg/l CMC for the field of measured quantity: Physicochemical quantities |
Dry gas | 114-MP-C004, kap č. 5.3.1 | |
| 195 | Ethanol concentration / breath alcohol analyzers | Calibration – physicochemical quantities Gas phase — 0 mg/l to 0,480 mg/l · CMC od 0,008 mg/l od 0,013 mg/l CMC for the field of measured quantity: Physicochemical quantities |
Simulation method | 114-MP-C004, kap č. 5.3.2 | |
| Regional Inspectorate Brno | |||||
| 196 | Gauge blocks | Calibration – length 2nd order — 0,1 mm to 1 000 mm · CMC (0,5L +0,05) µm 3rd order — 0,1 mm to 1 000 mm · CMC (1L +0,1) µm 4th order — 0,1 mm to 1 000 mm · CMC (2L +0,2) µm 5th order — 0,1 mm to 1 000 mm · CMC (5L +0,5) µm CMC for the field of measured quantity: Length |
Mechanical comparison with a standard using a comparator or length gauge | 614-MP-C033 (ČSN EN ISO 3650) | |
| 197 | Mechanical comparators of nominal length (0.3 to 100) mm | Calibration – length -0,01 mm to +0,01 mm · CMC 0,032 µm CMC for the field of measured quantity: Length |
Comparison using gauge blocks | 614-MP-C005 | |
| 198 | Length measuring instruments and gauges | Calibration – length from 0 m to 20 m · CMC (0,4L +0,02) µm CMC for the field of measured quantity: Length |
Direct measurement by a laser interferometer | 614-MP-C006 | |
| 199 | Micrometers | Calibration – length from 0 mm to 500 mm · CMC (5L +1,5) µm CMC for the field of measured quantity: Length |
Comparison with gauge blocks and gauges | 614-MP-C008 | |
| 200 | Calipers | Calibration – length 0 mm to 1 000 mm · CMC 20 µm CMC for the field of measured quantity: Length |
Comparison with gauge blocks, gauges and rings | 614-MP-C009 | |
| 201 | Length measuring instruments, meters and gauges | Calibration – length 0 mm to 1 000 mm · CMC (2L +0,2) µm CMC for the field of measured quantity: Length |
Direct measurement by a length gauge | 614-MP-C029 | |
| 202 | Test sieves | Calibration – length 0,005 mm to 150 mm · CMC (4L +1,5) µm CMC for the field of measured quantity: Length |
Calibration on a 2D optical instrument, using slide gauge or limit gauges | 614-MP-C102 | |
| 203 | Roundness / balls, rings, cylinders, cones | Calibration – length Maximum diameter 350 mm — -2 mm to +2 mm · CMC Q[0,025;0,01R] µm CMC for the field of measured quantity: Length |
Direct measurement by a ring gauge | 614-MP-C103 | |
| 204 | Straightness and parallelity / rings, cylinders, cones, straightness and parallelity standards | Calibration – length Maximum horizontal path: 200 mm; Maximum vertical path: 300 mm — -2 mm to +2 mm · CMC Q[0,2;0,01R] µm CMC for the field of measured quantity: Length |
Direct measurement by a ring gauge | 614-MP-C103 | |
| 205 | Diameter / thread limit gauges, plain limit gauges | Calibration – length from 1 mm to 100 mm · CMC 2,5 µm CMC for the field of measured quantity: Length |
Calibration on IAC MasterScanner XP 10060 analyzer | 614-MP-C106 | |
| 206 | Gauges, standards, artefacts | Calibration – length 0 mm to 2 550 mm · CMC Q[0,09; 0,4L] µm CMC for the field of measured quantity: Length |
Measurement on a coordinate measuring machine | 815-MP-C503 | |
| 207 | Coordinate measuring machine / system | Calibration – length tactile — 0 m to 6 m · CMC Q[0,01;0,2L] µm optical — 0 m to 3 m · CMC Q[0,01;0,2L] µm multisensor — 0 m to 3 m · CMC Q[0,01;0,2L] µm optical 3D — 0 m to 3 m · CMC Q[0,3;1L] µm articulated arm — 0 m to 4,5 m · CMC Q[0,3;1L] µm computer tomography — 0 m to 1,5 m · CMC Q[0,3;1L] µm laser-trackers — 0 m to 30 m · CMC Q[0,3;1L] µm CMC for the field of measured quantity: Length |
Comparison with the standard | 815-MP-C501 | |
| 208 | Counting efficiency / Optical counters of aerosol particles | Calibration – length Particle size (0 to 50) µm — 0 η to 5 η · CMC 9 % CMC for the field of measured quantity: Length |
Comparison with PSL particles | 614-MP-C105, ISO 21501-4 čl. 6.2, 6.4, 6.6 | |
| 209 | Grating period | Calibration – length 0 nm to 200 µm · CMC 0,5 nm CMC for the field of measured quantity: Length |
Measurements using an atomic force microscope | 614-MP-C002 | |
| 210 | Step height | Calibration – length 0 nm to 20 µm · CMC 1 nm CMC for the field of measured quantity: Length |
Measurements using an atomic force microscope | 614-MP-C146 | |
| 211 | Static volume/ Measuring vessels | Calibration – volume, flow rate Distilled water — 0,2 mL to 21 000 mL · CMC 0,01 % CMC for the field of measured quantity: Volume, flow rate |
Gravimetric method | 616-MP-C016 (ČSN EN ISO 4787, EURAMET cg-19) | |
| 212 | Static volume/ metal measuring vessels – limit, scaled, with a graduation mark | Calibration – volume, flow rate Distilled water / water — 2 L to 1 000 L · CMC 0,01 % CMC for the field of measured quantity: Volume, flow rate |
Gravimetric method | 615-MP-C151 (ČSN EN ISO 4787, EURAMET cg-19) | |
| 213 | Static volume / Piston volume meters | Calibration – volume, flow rate piston pipettes and syringes; Distilled water — 0,5 µL to 10 000 µL · CMC 0,13 % + 0,01 µL other piston gauges; Distilled water — 10 µL to 200 000 µL · CMC 0,04 % CMC for the field of measured quantity: Volume, flow rate |
Gravimetric method | 616-MP-C017 (ČSN EN ISO 8655-6 EURAMET cg-19) | |
| 214 | Flow velocity | Calibration – volume, flow rate Air; anemometers — 0,3 m·s⁻¹ to 5 m·s⁻¹ · CMC 0,3 % + 0,01 m·s⁻¹ Air; anemometers — 5 m·s⁻¹ to 50 m·s⁻¹ · CMC 0,5 % CMC for the field of measured quantity: Volume, flow rate |
Comparison with a LDA standard | 615-MP-C147 | |
| 215 | Flow velocity | Calibration – volume, flow rate Air; anemometers — 0,5 m·s⁻¹ to 5 m·s⁻¹ · CMC 0,5 % + 0,01 m·s⁻¹ Air; anemometers — 5 m·s⁻¹ to 50 m·s⁻¹ · CMC 0,7 % CMC for the field of measured quantity: Volume, flow rate |
Comparison with a standard – Pitot tube | 615-MP-C147 | |
| 216 | Flow velocity | Calibration – volume, flow rate anemometers in the traction line — 0,05 m·s⁻¹ to 0,5 m·s⁻¹ · CMC 0,5 % + 0,005 m·s⁻¹ CMC for the field of measured quantity: Volume, flow rate |
Comparison with a standard – Pitot tube | 615-MP-C149 | |
| 217 | Water flow meters (water meters), flow meters of heat meters and flow meters tested by water | Calibration – volume, flow rate Water; volume or volume flow rate; (10 to 30) °C — 0,05 m³·h⁻¹ to 150 m³·h⁻¹ · CMC 0,10 % Water; mass or mass flow rate; (10 to 30) °C — 0,05 t·h⁻¹ to 150 t·h⁻¹ · CMC 0,10 % Water; volume or volume flow rate; (10 to 90) °C — 0,002 m³·h⁻¹ to 0,005 m³·h⁻¹ · CMC 0,25 % Water; volume or volume flow rate; (10 to 90) °C — 0,005 m³·h⁻¹ to 0,012 m³·h⁻¹ · CMC 0,16 % Water; volume or volume flow rate; (10 to 90) °C — 0,012 m³·h⁻¹ to 0,025 m³·h⁻¹ · CMC 0,09 % Water; volume or volume flow rate; (10 to 90) °C — 0,025 m³·h⁻¹ to 0,050 m³·h⁻¹ · CMC 0,07 % Water; volume or volume flow rate; (10 to 90) °C — 0,050 m³·h⁻¹ to 10 m³·h⁻¹ · CMC 0,05 % Water; volume or volume flow rate; (10 to 30) °C — 0,7 m³·h⁻¹ to 60 m³·h⁻¹ · CMC 0,10 % Water; volume or volume flow rate; (30 to 90) °C — 0,7 m³·h⁻¹ to 60 m³·h⁻¹ · CMC 0,12 % CMC for the field of measured quantity: Volume, flow rate |
Gravimetric method | 615-MP-C142 | |
| 218 | Water flow meters (water meters), flow meters of heat meters and flow meters tested by water | Calibration – volume, flow rate Water; volume or volume flow rate; (10 to 30) °C — 0,002 m³·h⁻¹ to 0,1 m³·h⁻¹ · CMC 0,10 % Water; volume or volume flow rate; (30 to 90) °C — 0,002 m³·h⁻¹ to 0,1 m³·h⁻¹ · CMC 0,12 % Water; volume or volume flow rate; (10 to 30) °C — 0,1 m³·h⁻¹ to 6 m³·h⁻¹ · CMC 0,06 % Water; volume or volume flow rate; (30 to 90) °C — 0,1 m³·h⁻¹ to 6 m³·h⁻¹ · CMC 0,08 % CMC for the field of measured quantity: Volume, flow rate |
Volume method with a piston | 615-MP-C142 | |
| 219 | Volume flow rate or volume / Flow meters for liquids other than water | Calibration – volume, flow rate Hydrocarbons based liquids — 3 dm³·min⁻¹ to 1 000 dm³·min⁻¹ · CMC 0,10 % CMC for the field of measured quantity: Volume, flow rate |
Volume method with a piston | 615-MP-C143 | |
| 220 | Mass flow rate or mass / meters and measuring systems for cryogenic liquids | Calibration – volume, flow rate Cryogenic liquids — 70 kg·min⁻¹ to 400 kg·min⁻¹ · CMC 0,50 % CMC for the field of measured quantity: Volume, flow rate |
Mass method with a measuring loop | 615-MP-C148 | |
| 221 | Mass or mass flow rate / Micro-flow meters | Calibration – volume, flow rate Distilled water (20 to 30) °C — 1 g·h⁻¹ to 50 g·h⁻¹ · CMC 0,30 % Distilled water (20 to 30) °C — 50 g·h⁻¹ to 6 000 g·h⁻¹ · CMC 0,16 % CMC for the field of measured quantity: Volume, flow rate |
Gravimetric method | 615-MP-C158 | |
| 222 | Volume or volume flow rate / Micro-flow meters | Calibration – volume, flow rate 1 ml·h⁻¹ to 50 ml·h⁻¹ · CMC 0,30 % 50 ml·h⁻¹ to 6 000 ml·h⁻¹ · CMC 0,16 % CMC for the field of measured quantity: Volume, flow rate |
Volumetric method with a flow meter or a piston | 615-MP-C158 | |
| 223 | Mass of weights | Calibration – mass from 1 mg to 20 mg · CMC 0,001 0 mg 50 mg · CMC 0,001 3 mg 100 mg · CMC 0,001 6 mg 200 mg · CMC 0,002 0 mg 500 mg · CMC 0,002 6 mg 1 g · CMC 0,003 mg 2 g · CMC 0,004 mg 5 g · CMC 0,005 mg 10 g · CMC 0,006 mg 20 g · CMC 0,008 mg 50 g · CMC 0,010 mg 100 g · CMC 0,016 mg 200 g · CMC 0,030 mg 500 g · CMC 0,080 mg 1 kg · CMC 0,15 mg 2 kg · CMC 0,30 mg 5 kg · CMC 0,80 mg 10 kg · CMC 1,5 mg 20 kg · CMC 3,3 mg 50 kg · CMC 8 mg 100 kg · CMC 50 mg 200 kg · CMC 100 mg 500 kg · CMC 250 mg 1 000 kg · CMC 500 mg CMC for the field of measured quantity: Mass |
Comparison with a reference weight | 612-MP-C131 | |
| 224 | Balances with non-automatic and automatic function | Calibration – mass Weight E2 — 0 g to 20 kg · CMC 5·10⁻⁷ Weight F1 — 20 kg to 50 kg · CMC 1,6·10⁻⁶ Weight F2 — 50 kg to 600 kg · CMC 5·10⁻⁶ Weight M — 600 kg to 200 000 kg · CMC 1,6·10⁻⁵ CMC for the field of measured quantity: Mass |
Loading using a reference weight | 612-MP-C132 | |
| 225 | Glass thermometers | Calibration – temperature division < 0.1 °C — -90 °C to 100 °C · CMC 0,015 °C division < 0.1 °C — 100 °C to 150 °C · CMC 0,020 °C division < 0.1 °C — 150 °C to 210 °C · CMC 0,040 °C division < 0.1 °C — 210 °C to 360 °C · CMC 0,050 °C 0.1 °C ≤ division ≤ 1 °C — 360 °C to 420 °C · CMC 0,15 °C 0.1 °C ≤ division ≤ 1 °C — 420 °C to 550 °C · CMC 0,20 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in liquid bath | 133-MP-C001 | |
| 226 | Resistance temperature sensors | Calibration – temperature 0,01 °C · CMC 0,002 °C CMC for the field of measured quantity: Temperature |
Direct measurement at triple point of water | 133-MP-C002 | |
| 227 | Resistance temperature sensors | Calibration – temperature 660,32 °C · CMC 0,05 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor at a fixed point | 133-MP-C002 | |
| 228 | Resistance temperature sensors | Calibration – temperature -196 °C · CMC 0,03 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor near the boiling point of nitrogen | 133-MP-C002 | |
| 229 | Resistance temperature sensors | Calibration – temperature od -100 °C do -90 °C · CMC 0,2 °C from 550 °C to 660 °C · CMC 0,09 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in a vertical furnace | 133-MP-C002 | |
| 230 | Resistance temperature sensors | Calibration – temperature from -90 °C to -80 °C · CMC 0,015 °C od -80 °C do 160 °C · CMC 0,01 °C od 160 °C do 300 °C · CMC 0,02 °C from 300 °C to 420 °C · CMC 0,03 °C od 420 °C do 550 °C · CMC 0,05 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in liquid bath | 133-MP-C002 | |
| 231 | Thermocouple temperature sensors | Calibration – temperature Noble metals — 0 °C to 220 °C · CMC 0,4 °C Noble metals — 220 °C to 550 °C · CMC 0,5 °C Base metals — -90 °C to 220 °C · CMC 0,2 °C Base metals — 220 °C to 550 °C · CMC 0,4 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in liquid bath | 133-MP-C003 | |
| 232 | Thermocouple temperature sensors | Calibration – temperature Noble metals — 550 °C to 1 100 °C · CMC 0,8 °C Noble metals — 1 100 °C to 1 300 °C · CMC 1,3 °C Noble metals — 1 300 °C to 1 600 °C · CMC 2,1 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference thermoelectric temperature sensor in a horizontal furnace | 133-MP-C003 | |
| 233 | Thermocouple temperature sensors | Calibration – temperature Base metals — -196 °C · CMC 0,3 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor near the boiling point of nitrogen | 133-MP-C003 | |
| 234 | Thermocouple temperature sensors | Calibration – temperature Base metals — -100 °C to -90 °C · CMC 0,3 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in a vertical furnace | 133-MP-C003 | |
| 235 | Thermocouple temperature sensors | Calibration – temperature Base metals — 550 °C to 1 100 °C · CMC 1,0 °C Base metals — 1 100 °C to 1 300 °C · CMC 1,4 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference thermoelectric temperature sensor in a calibration furnace | 133-MP-C003 | |
| 236 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature 0,01 °C · CMC 0,002 °C CMC for the field of measured quantity: Temperature |
Direct measurement at triple point of water | 133-MP-C004 | |
| 237 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature 660,32 °C · CMC 0,05 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor at a fixed point | 133-MP-C004 | |
| 238 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature -196 °C · CMC 0,03 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor near the boiling point of nitrogen | 133-MP-C004 | |
| 239 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature -196 °C to -100 °C · CMC 0,3 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor on the customer's equipment | 133-MP-C004 | |
| 240 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature od -100 °C do -90 °C · CMC 0,2 °C from 550 °C to 660 °C · CMC 0,09 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in a vertical furnace | 133-MP-C004 | |
| 241 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature from -90 °C to -80 °C · CMC 0,015 °C od -80 °C do 160 °C · CMC 0,01 °C od 160 °C do 300 °C · CMC 0,02 °C from 300 °C to 420 °C · CMC 0,03 °C od 420 °C do 550 °C · CMC 0,05 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance temperature sensor in liquid bath | 133-MP-C004 | |
| 242 | Indication thermometers including temperature measuring chains, their temperature probes and characterization of thermal chambers | Calibration – temperature od 550 °C do 1 100 °C · CMC 0,7 °C from 1 100 °C to 1 300 °C · CMC 1,3 °C od 1 300 °C do 1 600 °C · CMC 1,8 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference temperature sensor in a furnace | 133-MP-C004 | |
| 243 | Infrared non-contact thermometers and measuring chains of infrared non-contact thermometers | Calibration – temperature Measuring chains with range limited to (-15 to 500) °C — -30 °C to -15 °C · CMC 2,2 °C Measuring chains with range limited to (-15 to 500) °C — -15 °C to 0 °C · CMC 1,6 °C Measuring chains with range limited to (-15 to 500) °C — 0 °C to 20 °C · CMC 1,1 °C Measuring chains with range limited to (-15 to 500) °C — 20 °C to 100 °C · CMC 0,8 °C Measuring chains with range limited to (-15 to 500) °C — 100 °C to 200 °C · CMC 1,1 °C Measuring chains with range limited to (-15 to 500) °C — 200 °C to 300 °C · CMC 1,4 °C Measuring chains with range limited to (-15 to 500) °C — 300 °C to 400 °C · CMC 1,7 °C Measuring chains with range limited to (-15 to 500) °C — 400 °C to 500 °C · CMC 2,2 °C Measuring chains with range limited to (-15 to 500) °C — 500 °C to 600 °C · CMC 2,6 °C Measuring chains with range limited to (-15 to 500) °C — 600 °C to 700 °C · CMC 2,9 °C CMC for the field of measured quantity: Temperature |
Comparison with the standard | 133-MP-C005 | |
| 244 | Thermal cameras | Calibration – temperature -30 °C to 500 °C · CMC 0,8 °C 500 °C to 1 000 °C · CMC 1,0 °C 1 000 °C to 1 300 °C · CMC 1,5 °C 1 300 °C to 1 800 °C · CMC 2,0 °C CMC for the field of measured quantity: Temperature |
Comparison with the standard | 112-MP-C005 | |
| 245 | Temperature calibrators | Calibration – temperature TC - R — -50 °C to 1 760 °C · CMC 0,12 °C TC - S — -50 °C to 1 760 °C · CMC 0,16 °C TC - B — 0 °C to 1 820 °C · CMC 0,14 °C TC - J — -210 °C to 1 200 °C · CMC 0,04 °C TC - T — -270 °C to 400 °C · CMC 0,04 °C TC - E — -270 °C to 1 000 °C · CMC 0,04 °C TC - K — -270 °C to 1 370 °C · CMC 0,05 °C TC - N — -270 °C to 1 300 °C · CMC 0,05 °C TC - M — -200 °C to 100 °C · CMC 0,03 °C TC - L — -200 °C to 800 °C · CMC 0,03 °C TC - A — 0 °C to 2 500 °C · CMC 0,24 °C TC – Fe-ko — -200 °C to 900 °C · CMC 0,04 °C RTD - Pt100 — -200 °C to 850 °C · CMC 0,02 °C RTD - Pt200 — -200 °C to 850 °C · CMC 0,02 °C RTD - Pt500 — -200 °C to 850 °C · CMC 0,03 °C RTD - Pt1000 — -200 °C to 850 °C · CMC 0,02 °C RTD - Ni100 — -60 °C to 250 °C · CMC 0,01 °C RTD - Ni1000 — -60 °C to 250 °C · CMC 0,01 °C CMC for the field of measured quantity: Temperature |
Comparison with a calibrator or electrical measurement using a multimeter | 611-MP-C130 | |
| 246 | Relative humidity / hygrometers and humidity measuring chains including humidity probes, characterization of climatic chambers | Calibration – air humidity Air temperature (10 to 90) °C — 5 % RH to 30 % RH · CMC 0,6 % RH Air temperature (10 to 90) °C — 30 % RH to 50 % RH · CMC 0,7 % RH Air temperature (10 to 90) °C — 50 % RH to 70 % RH · CMC 0,8 % RH Air temperature (10 to 90) °C — 70 % RH to 80 % RH · CMC 0,9 % RH Air temperature (10 to 90) °C — 80 % RH to 90 % RH · CMC 1,0 % RH Air temperature (10 to 90) °C — 90 % RH to 95 % RH · CMC 1,5 % RH CMC for the field of measured quantity: Air humidity |
Comparison with a standard hygrometer | 636-MP-C119 | |
| 247 | Dew point temperature / hygrometers | Calibration – air humidity od -75 °C do -65 °C · CMC 0,24 °C od -65 °C do -50 °C · CMC 0,16 °C from -50 °C to -30 °C · CMC 0,10 °C od -30 °C do 60 °C · CMC 0,08 °C od 60 °C do 80 °C · CMC 0,10 °C od 80 °C do 90 °C · CMC 0,15 °C CMC for the field of measured quantity: Air humidity |
Comparison with a standard thermometer | 636-MP-C120 | |
| 248 | DC voltage / DC voltage sources and meters | Calibration – electrical quantities from 0 mV to 20 mV · CMC 15·10⁻⁶·U + 0,05 µV from 20 mV to 200 mV · CMC 5,0·10⁻⁶·U from 200 mV to 2 V · CMC 2,6·10⁻⁶·U from 2 V to 20 V · CMC 2,1·10⁻⁶·U od 10 V do 10 V · CMC 1,5 µV od 20 V do 1 100 V · CMC 2,9·10⁻⁶·U CMC for the field of measured quantity: Electrical quantities |
Direct comparison with a calibrator or direct measurement by a multimeter | 611-MP-C097, 611-MP-C098 | |
| 249 | DC voltage / DC voltage sources and meters | Calibration – electrical quantities od 0 V do 2 V · CMC 1,5·10⁻⁶·U + 0,05 µV from 2 V to 20 V · CMC 0,8·10⁻⁶·U od 20 V do 1 100 V · CMC 1,6·10⁻⁶·U CMC for the field of measured quantity: Electrical quantities |
Comparison with a voltage reference using a resistive divider | 611-MP-C005 | |
| 250 | AC voltage / AC voltage sources and meters | Calibration – electrical quantities 10 Hz to 75 kHz — 0,9 mV to 2 mV · CMC 0,20 % 75 kHz to 400 kHz — 0,9 mV to 2 mV · CMC 0,31 % 400 kHz to 750 kHz — 0,9 mV to 2 mV · CMC 0,33 % 750 kHz to 1 MHz — 0,9 mV to 2 mV · CMC 0,35 % 10 Hz to 25 kHz — 2 mV to 20 mV · CMC 360·10⁻⁶·U 25 kHz to 75 kHz — 2 mV to 20 mV · CMC 330·10⁻⁶·U 75 kHz to 200 kHz — 2 mV to 20 mV · CMC 530·10⁻⁶·U 200 kHz to 400 kHz — 2 mV to 20 mV · CMC 710·10⁻⁶·U 400 kHz to 750 kHz — 2 mV to 20 mV · CMC 790·10⁻⁶·U 750 kHz to 1 MHz — 2 mV to 20 mV · CMC 1100·10⁻⁶·U 10 Hz to 25 kHz — 20 mV to 200 mV · CMC 98·10⁻⁶·U 25 kHz to 75 kHz — 20 mV to 200 mV · CMC 190·10⁻⁶·U 75 kHz to 200 kHz — 20 mV to 200 mV · CMC 370·10⁻⁶·U 200 kHz to 400 kHz — 20 mV to 200 mV · CMC 590·10⁻⁶·U 400 kHz to 750 kHz — 20 mV to 200 mV · CMC 650·10⁻⁶·U 750 kHz to 1 MHz — 20 mV to 200 mV · CMC 1000·10⁻⁶·U 10 Hz to 35 Hz — 200 mV to 2 V · CMC 37·10⁻⁶·U 35 Hz to 40 kHz — 200 mV to 2 V · CMC 26·10⁻⁶·U 40 kHz to 75 kHz — 200 mV to 2 V · CMC 37·10⁻⁶·U 75 kHz to 200 kHz — 200 mV to 2 V · CMC 48·10⁻⁶·U 200 kHz to 400 kHz — 200 mV to 2 V · CMC 120·10⁻⁶·U 400 kHz to 750 kHz — 200 mV to 2 V · CMC 230·10⁻⁶·U 750 kHz to 1 MHz — 200 mV to 2 V · CMC 590·10⁻⁶·U 10 Hz to 35 Hz — 2 V to 20 V · CMC 37·10⁻⁶·U 35 Hz to 40 kHz — 2 V to 20 V · CMC 26·10⁻⁶·U 40 kHz to 75 kHz — 2 V to 20 V · CMC 33·10⁻⁶·U 75 kHz to 200 kHz — 2 V to 20 V · CMC 40·10⁻⁶·U 200 kHz to 400 kHz — 2 V to 20 V · CMC 110·10⁻⁶·U 400 kHz to 750 kHz — 2 V to 20 V · CMC 210·10⁻⁶·U 750 kHz to 1 MHz — 2 V to 20 V · CMC 560·10⁻⁶·U 10 Hz to 35 Hz — 20 V to 200 V · CMC 42·10⁻⁶·U 35 Hz to 175 Hz — 20 V to 200 V · CMC 37·10⁻⁶·U 175 Hz to 40 kHz — 20 V to 200 V · CMC 28·10⁻⁶·U 40 kHz to 75 kHz — 20 V to 200 V · CMC 40·10⁻⁶·U 75 kHz to 150 kHz — 20 V to 200 V · CMC 71·10⁻⁶·U 150 kHz to 200 kHz — 20 V to 200 V · CMC 240·10⁻⁶·U 10 Hz to 5 kHz — 200 V to 1 100 V · CMC 40·10⁻⁶·U 5 kHz to 25 kHz — 200 V to 1 100 V · CMC 45·10⁻⁶·U 25 kHz to 40 kHz — 200 V to 1 100 V · CMC 76·10⁻⁶·U 40 kHz to 750 kHz — 200 V to 1 100 V · CMC 120·10⁻⁶·U Generation only up to 750 V; 75 kHz to 100 kHz — 200 V to 1 100 V · CMC 350·10⁻⁶·U CMC for the field of measured quantity: Electrical quantities |
Direct comparison with a calibrator or direct measurement by a multimeter | 611-MP-C097 611-MP-C098 | |
| 251 | Low AC voltages / AC voltage meters | Calibration – electrical quantities 50 Hz to 200 Hz — 0,1 µV to 1 µV · CMC 0,50 % 200 Hz to 10 kHz — 0,1 µV to 1 µV · CMC 0,20 % 10 kHz to 100 kHz — 0,1 µV to 1 µV · CMC 0,70 % 50 Hz to 200 Hz — 1 µV to 1 mV · CMC 0,20 % 200 Hz to 10 kHz — 1 µV to 1 mV · CMC 0,07 % 10 kHz to 100 kHz — 1 µV to 1 mV · CMC 0,30 % CMC for the field of measured quantity: Electrical quantities |
Comparison or measurement using an impedance divider | 611-MP-C061 | |
| 252 | DC current / Low DC current generators | Calibration – electrical quantities 0 pA to 1 pA · CMC 1 fA 1 pA to 20 pA · CMC 0,13 % 20 pA to 200 pA · CMC 0,11 % 0,2 nA to 2 nA · CMC 0,08 % 2 nA to 20 nA · CMC 0,06 % 20 nA to 200 nA · CMC 0,05 % 0,2 µA to 2 µA · CMC 0,04 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a picoammeter | 611-MP-C034 | |
| 253 | DC current / Low DC current meters | Calibration – electrical quantities 0 pA to 1 pA · CMC 1 fA 1 pA to 20 pA · CMC 0,11 % 20 pA to 200 pA · CMC 0,06 % 0,2 nA to 2 nA · CMC 0,03 % 2 nA to 20 nA · CMC 0,025 % 20 nA to 200 nA · CMC 0,020 % 0,2 µA to 2 µA · CMC 0,008 % CMC for the field of measured quantity: Electrical quantities |
Indirect generation using a DC voltage source and standard resistors | 611-MP-C034 | |
| 254 | DC current / DC current generators | Calibration – electrical quantities from 0 µA to 1 µA · CMC 0,10 nA from 1 µA to 100 µA · CMC 21·10⁻⁶·I from 100 µA to 200 µA · CMC 12·10⁻⁶·I od 200 µA do 2 A · CMC 6,0·10⁻⁶·I from 2 A to 20 A · CMC 15·10⁻⁶·I from 20 A to 100 A · CMC 20·10⁻⁶·I CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a multimeter or indirect measurement using a current shunt | 611-MP-C097 | |
| 255 | DC current / DC current meters | Calibration – electrical quantities from 0 µA to 1 µA · CMC 0,10 nA from 1 µA to 100 µA · CMC 21·10⁻⁶·I from 100 µA to 200 µA · CMC 15·10⁻⁶·I from 200 µA to 20 mA · CMC 6,0·10⁻⁶·I from 20 mA to 200 mA · CMC 8,0·10⁻⁶·I from 200 mA to 2 A · CMC 15·10⁻⁶·I od 2 A do 100 A · CMC 30·10⁻⁶·I CMC for the field of measured quantity: Electrical quantities |
Direct generation by a calibrator | 611-MP-C098 | |
| 256 | AC current / AC current generators | Calibration – electrical quantities 10 Hz to 20 Hz — 9 µA to 2 mA · CMC 100·10⁻⁶·I 20 Hz to 40 Hz — 9 µA to 2 mA · CMC 90·10⁻⁶·I 40 Hz to 5 kHz — 9 µA to 2 mA · CMC 70·10⁻⁶·I 5 kHz to 10 kHz — 9 µA to 2 mA · CMC 80·10⁻⁶·I 10 kHz to 30 kHz — 9 µA to 2 mA · CMC 300·10⁻⁶·I 10 Hz to 20 Hz — 2 mA to 20 mA · CMC 90·10⁻⁶·I 20 Hz to 40 Hz — 2 mA to 20 mA · CMC 75·10⁻⁶·I 40 Hz to 1 kHz — 2 mA to 20 mA · CMC 65·10⁻⁶·I 1 kHz to 10 kHz — 2 mA to 20 mA · CMC 70·10⁻⁶·I 10 kHz to 30 kHz — 2 mA to 20 mA · CMC 300·10⁻⁶·I 10 Hz to 20 Hz — 20 mA to 200 mA · CMC 80·10⁻⁶·I 20 Hz to 1 kHz — 20 mA to 200 mA · CMC 65·10⁻⁶·I 1 kHz to 5 kHz — 20 mA to 200 mA · CMC 70·10⁻⁶·I 5 kHz to 10 kHz — 20 mA to 200 mA · CMC 80·10⁻⁶·I 10 kHz to 30 kHz — 20 mA to 200 mA · CMC 300·10⁻⁶·I 10 Hz to 20 Hz — 200 mA to 2 A · CMC 120·10⁻⁶·I 20 Hz to 40 Hz — 200 mA to 2 A · CMC 100·10⁻⁶·I 40 Hz to 1 kHz — 200 mA to 2 A · CMC 90·10⁻⁶·I 1 kHz to 5 kHz — 200 mA to 2 A · CMC 100·10⁻⁶·I 5 kHz to 10 kHz — 200 mA to 2 A · CMC 120·10⁻⁶·I 10 kHz to 30 kHz — 200 mA to 2 A · CMC 500·10⁻⁶·I 10 Hz to 20 Hz — 2 A to 20 A · CMC 180·10⁻⁶·I 20 Hz to 40 Hz — 2 A to 20 A · CMC 160·10⁻⁶·I 40 Hz to 1 kHz — 2 A to 20 A · CMC 110·10⁻⁶·I 1 kHz to 5 kHz — 2 A to 20 A · CMC 140·10⁻⁶·I 5 kHz to 10 kHz — 2 A to 20 A · CMC 160·10⁻⁶·I 10 Hz to 20 Hz — 20 A to 100 A · CMC 250·10⁻⁶·I 20 Hz to 40 Hz — 20 A to 100 A · CMC 160·10⁻⁶·I 40 Hz to 1 kHz — 20 A to 100 A · CMC 120·10⁻⁶·I 1 kHz to 5 kHz — 20 A to 100 A · CMC 150·10⁻⁶·I 5 kHz to 10 kHz — 20 A to 100 A · CMC 200·10⁻⁶·I CMC for the field of measured quantity: Electrical quantities |
Direct measurement by a multimeter or indirect measurement using current shunts | 611-MP-C097 | |
| 257 | AC current / AC current meters | Calibration – electrical quantities 10 Hz to 35 Hz — 9 µA to 200 µA · CMC 130·10⁻⁶·I 35 Hz to 1 kHz — 9 µA to 200 µA · CMC 100·10⁻⁶·I 1 kHz to 5 kHz — 9 µA to 200 µA · CMC 160·10⁻⁶·I 5 kHz to 10 kHz — 9 µA to 200 µA · CMC 800·10⁻⁶·I 10 kHz to 30 kHz — 9 µA to 200 µA · CMC 2 000·10⁻⁶·I 10 Hz to 35 Hz — 200 µA to 2 mA · CMC 120·10⁻⁶·I 35 Hz to 1 kHz — 200 µA to 2 mA · CMC 90·10⁻⁶·I 1 kHz to 10 kHz — 200 µA to 2 mA · CMC 140·10⁻⁶·I 10 kHz to 30 kHz — 200 µA to 2 mA · CMC 700·10⁻⁶·I 10 Hz to 35 Hz — 2 mA to 200 mA · CMC 120·10⁻⁶·I 35 Hz to 1 kHz — 2 mA to 200 mA · CMC 75·10⁻⁶·I 1 kHz to 5 kHz — 2 mA to 200 mA · CMC 130·10⁻⁶·I 5 kHz to 10 kHz — 2 mA to 200 mA · CMC 140·10⁻⁶·I 10 kHz to 30 kHz — 2 mA to 200 mA · CMC 700·10⁻⁶·I 10 Hz to 35 Hz — 200 mA to 2 A · CMC 170·10⁻⁶·I 35 Hz to 1 kHz — 200 mA to 2 A · CMC 120·10⁻⁶·I 1 kHz to 10 kHz — 200 mA to 2 A · CMC 220·10⁻⁶·I 10 Hz to 35 Hz — 2 A to 20 A · CMC 310·10⁻⁶·I 35 Hz to 1 kHz — 2 A to 20 A · CMC 200·10⁻⁶·I 1 kHz to 5 kHz — 2 A to 20 A · CMC 300·10⁻⁶·I 5 kHz to 10 kHz — 2 A to 20 A · CMC 690·10⁻⁶·I 10 Hz to 35 Hz — 20 A to 100 A · CMC 350·10⁻⁶·I 35 Hz to 1 kHz — 20 A to 100 A · CMC 200·10⁻⁶·I 1 kHz to 5 kHz — 20 A to 100 A · CMC 300·10⁻⁶·I 5 kHz to 10 kHz — 20 A to 100 A · CMC 950·10⁻⁶·I CMC for the field of measured quantity: Electrical quantities |
Direct generation by a calibrator | 611-MP-C098 | |
| 258 | DC resistance / DC resistance standards and resistance meters | Calibration – electrical quantities 100 µΩ · CMC 0,72 nΩ 1 mΩ · CMC 3,5 nΩ 10 mΩ · CMC 26 nΩ 20 mΩ · CMC 44 nΩ 100 mΩ · CMC 86 nΩ 1 Ω · CMC 0,76 µΩ 10 Ω · CMC 7,1 µΩ 25 Ω · CMC 16 µΩ 100 Ω · CMC 35 µΩ 1 kΩ · CMC 0,35 mΩ 10 kΩ · CMC 3,8 mΩ 100 kΩ · CMC 59 mΩ 1 MΩ · CMC 4,0 Ω 10 MΩ · CMC 70 Ω 100 MΩ · CMC 160 Ω 1 GΩ · CMC 100 kΩ 10 GΩ · CMC 5,0 MΩ 100 GΩ · CMC 25 MΩ 1 TΩ · CMC 200 MΩ CMC for the field of measured quantity: Electrical quantities |
Comparison by the ratio method – measuring voltage drops at a constant measuring current, or direct measurement of the standard resistor | 131-MP-C003, 131-MP-C005, 611-MP-C097, 611-MP-C098 | |
| 259 | DC resistance / DC resistance standards and resistance meters | Calibration – electrical quantities od 0 µΩ do 100 µΩ · CMC 3,5·10⁻⁶·R + 0,5 nΩ od 100 µΩ do 200 µΩ · CMC 7,2·10⁻⁶·R od 200 µΩ do 1 mΩ · CMC 6,0·10⁻⁶·R od 1 mΩ do 2 mΩ · CMC 3,5·10⁻⁶·R od 2 mΩ do 10 mΩ · CMC 5,6·10⁻⁶·R od 10 mΩ do 20 mΩ · CMC 2,6·10⁻⁶·R od 20 mΩ do 100 mΩ · CMC 1,6·10⁻⁶·R from 100 mΩ to 200 mΩ · CMC 0,86·10⁻⁶·R from 200 mΩ to 1 Ω · CMC 1,6·10⁻⁶·R from 1 Ω to 2 Ω · CMC 0,73·10⁻⁶·R od 2 Ω do 10 Ω · CMC 1,6·10⁻⁶·R from 10 Ω to 20 Ω · CMC 0,71·10⁻⁶·R od 20 Ω do 100 Ω · CMC 1,2·10⁻⁶·R od 100 Ω do 200 Ω · CMC 0,35·10⁻⁶·R od 200 Ω do 1 kΩ · CMC 0,93·10⁻⁶·R from 1 kΩ to 2 kΩ · CMC 0,35·10⁻⁶·R from 2 kΩ to 10 kΩ · CMC 1,2·10⁻⁶·R od 10 kΩ do 20 kΩ · CMC 0,38·10⁻⁶·R from 20 kΩ to 100 kΩ · CMC 0,86·10⁻⁶·R from 100 kΩ to 200 kΩ · CMC 0,59·10⁻⁶·R from 200 kΩ to 1 MΩ · CMC 4,1·10⁻⁶·R from 1 MΩ to 2 MΩ · CMC 4,0·10⁻⁶·R od 2 MΩ do 10 MΩ · CMC 7,4·10⁻⁶·R od 10 MΩ do 20 MΩ · CMC 7,0·10⁻⁶·R from 20 MΩ to 200 MΩ · CMC 16·10⁻⁶·R from 200 MΩ to 1 GΩ · CMC 520·10⁻⁶·R from 1 GΩ to 2 GΩ · CMC 120·10⁻⁶·R from 2 GΩ to 10 GΩ · CMC 0,52 % from 10 GΩ to 20 GΩ · CMC 0,12 % CMC for the field of measured quantity: Electrical quantities |
Comparison by the ratio method – measuring voltage drops at a constant measuring current, or direct measurement of the standard resistor | 131-MP-C003, 131-MP-C005, 611-MP-C097, 611-MP-C098 | |
| 260 | Resistance ratio / Thermometric bridges 0 Hz to 400 Hz | Calibration – electrical quantities 0 to 4 · CMC 1,6·10⁻⁸ CMC for the field of measured quantity: Electrical quantities |
Measurement by a set of standard resistors or a simulated resistance ratio generated by an inductive divider | 611-MP-C045 | |
| 261 | DC power / DC electric power meters for voltage 1 V to 1000 V and current 1 mA to 120 A | Calibration – electrical quantities 1 mW to 120 kW · CMC 0,0025% CMC for the field of measured quantity: Electrical quantities |
Measurement by a digital sampling wattmeter | 611-MP-C042 | |
| 262 | Single-phase and three-phase AC active power / active electric power meters for voltage 1 V to 1000 V, current 1 mA to 200 A, power factor 0 to 1, frequency 15 Hz to 1000 Hz | Calibration – electrical quantities 1 mW to 600 kW · CMC 25 µW/VA CMC for the field of measured quantity: Electrical quantities |
Measurement by a digital sampling wattmeter | 611-MP-C042 | |
| 263 | Single-phase and three-phase AC reactive power / reactive electric power meters for voltage 1 V to 1000 V, current 1 mA to 200 A, power factor 0 to 1, frequency 15 Hz to 1000 Hz | Calibration – electrical quantities 1 mvar to 600 kvar · CMC 25 µvar/VA CMC for the field of measured quantity: Electrical quantities |
Measurement by a digital sampling wattmeter | 611-MP-C042 | |
| 264 | Phase angle / Phase angle meters | Calibration – electrical quantities 0,1 µV to 1 µV; 400 Hz to 1,592 kHz — 0 ° to 360 ° · CMC 0,10° 1 µV to 100 µV; 400 Hz to 1,592 kHz — 0 ° to 360 ° · CMC 0,050° 0,1 mV to 1 mV; 400 Hz to 1,592 kHz — 0 ° to 360 ° · CMC 0,10° 1 mV to 10 mV; 400 Hz to 1,592 kHz — 0 ° to 360 ° · CMC 0,050° CMC for the field of measured quantity: Electrical quantities |
Measurement on a phase calibrator and impedance divider | 611-MP-C061 | |
| 265 | Phase angle / Phase angle meters | Calibration – electrical quantities 10 mV to 560 V; 1 Hz to 6 kHz — 0 ° to 360 ° · CMC 0,0010° 10 mV to 560 V; 6 kHz to 50 kHz — 0 ° to 360 ° · CMC 0,0020° 10 mV to 100 V; 50 kHz to 100 kHz — 0 ° to 360 ° · CMC 0,050° 10 mV to 1 V; 100 kHz to 1 MHz — 0 ° to 360 ° · CMC 0,050° 10 mV to 1 V; 1 MHz to 10 MHz — 0 ° to 360 ° · CMC 0,10° CMC for the field of measured quantity: Electrical quantities |
By digital signal sampling | 611-MP-C060 | |
| 266 | Single-phase and three-phase electrical energy / DC and AC electrical energy meters for voltage 1 V to 1000 V, current 1 mA to 120 A, power factor 0 to 1, frequency 0 Hz and 15 Hz to 800 Hz, time 1 s to 3600 s | Calibration – electrical quantities 1 Ws to 1296 MWs · CMC 0,010 % CMC for the field of measured quantity: Electrical quantities |
Comparison with a standard electricity meter; Measurement by a digital sampling wattmeter | 611-MP-C042 | |
| 267 | Flicker / Flicker meters | Calibration – electrical quantities 50 Hz — 0,5 Pst to 10 Pst · CMC 0,003·Pst CMC for the field of measured quantity: Electrical quantities |
Using digital signal sampling | 611-MP-C043 | |
| 268 | pH / pH meters | Calibration – electrical quantities from 0 pH to 14 pH · CMC 0,001 pH od -1 000 mV do 1 000 mV · CMC 0,010 mV CMC for the field of measured quantity: Electrical quantities |
Comparison with a calibrator by electrical means | 611-MP-C129 | |
| 269 | Capacitance / Capacitance meters | Calibration – electrical quantities 1 kHz — 10 pF · CMC 5 aF 1 kHz — 100 pF · CMC 50 aF 50 Hz to 200 Hz — 1 pF to 10 pF · CMC 0,015 % 200 Hz to 1 kHz — 1 pF to 10 pF · CMC 0,0070 % 1 kHz — 1 pF to 10 pF · CMC 0,0015 % 1 kHz to 10 kHz — 1 pF to 10 pF · CMC 0,0050 % 10 kHz to 1 MHz — 1 pF to 10 pF · CMC 0,010 % 1 MHz to 10 MHz — 1 pF to 10 pF · CMC 0,20 % 50 Hz to 1 kHz — 10 pF to 1 nF · CMC 0,0050 % 1 kHz — 10 pF to 1 nF · CMC 0,0007 % 1 kHz to 10 kHz — 10 pF to 1 nF · CMC 0,0050 % 10 kHz to 1 MHz — 10 pF to 1 nF · CMC 0,010 % 1 MHz to 10 MHz — 10 pF to 1 nF · CMC 0,20 % 50 Hz to 1 kHz — 1 nF to 10 nF · CMC 0,0070 % 1 kHz — 1 nF to 10 nF · CMC 0,0010 % 1 kHz to 10 kHz — 1 nF to 10 nF · CMC 0,0050 % 10 kHz to 1 MHz — 1 nF to 10 nF · CMC 0,010 % 1 MHz to 10 MHz — 1 nF to 10 nF · CMC 0,20 % 50 Hz to 200 Hz — 10 nF to 100 nF · CMC 0,010 % 200 Hz to 1 kHz — 10 nF to 100 nF · CMC 0,0030 % 1 kHz to 10 kHz — 10 nF to 100 nF · CMC 0,0070 % 10 kHz to 100 kHz — 10 nF to 100 nF · CMC 0,010 % 100 kHz to 1 MHz — 10 nF to 100 nF · CMC 0,030 % 50 Hz to 200 Hz — 100 nF to 1 µF · CMC 0,0070 % 200 Hz to 10 kHz — 100 nF to 1 µF · CMC 0,0050 % 10 kHz to 100 kHz — 100 nF to 1 µF · CMC 0,015 % 100 kHz to 1 MHz — 100 nF to 1 µF · CMC 0,050 % 20 Hz to 50 Hz — 1 µF to 10 µF · CMC 0,010 % 50 Hz to 1 kHz — 1 µF to 10 µF · CMC 0,0070 % 1 kHz — 1 µF to 10 µF · CMC 0,0050 % 1 kHz to 10 kHz — 1 µF to 10 µF · CMC 0,0060 % 10 kHz to 20 kHz — 1 µF to 10 µF · CMC 0,015 % 20 kHz to 100 kHz — 1 µF to 10 µF · CMC 0,050 % 20 Hz to 50 Hz — 10 µF to 100 µF · CMC 0,010 % 50 Hz to 1 kHz — 10 µF to 100 µF · CMC 0,0050 % 1 kHz to 10 kHz — 10 µF to 100 µF · CMC 0,0060 % 10 kHz to 20 kHz — 10 µF to 100 µF · CMC 0,020 % 20 Hz to 200 Hz — 100 µF to 1 mF · CMC 0,010 % 200 Hz to 1 kHz — 100 µF to 1 mF · CMC 0,015 % 1 kHz to 5 kHz — 100 µF to 1 mF · CMC 0,020 % 20 Hz to 200 Hz — 1 mF to 3 mF · CMC 0,020 % 200 Hz to 1 kHz — 1 mF to 3 mF · CMC 0,025 % 20 Hz to 200 Hz — 3 mF to 10 mF · CMC 0,030 % 0,1 Hz — 100 µF to 1 F · CMC 0,10 % CMC for the field of measured quantity: Electrical quantities |
Comparison with a standard using an impedance bridge | 611-MP-C030, 611-MP-C041 | |
| 270 | Dissipation factor D / Dissipation factor meters | Calibration – electrical quantities 1 pF to 10 pF; 50 Hz to 200 Hz — -0,001 to 0,001 · CMC 57·10⁻⁶ (abs.) 1 pF to 10 pF; 200 Hz to 1 kHz — -0,001 to 0,001 · CMC 8·10⁻⁶ (abs.) 1 pF to 10 pF; 1 kHz — -0,001 to 0,001 · CMC 3·10⁻⁶ (abs.) 1 pF to 10 pF; 1 kHz to 5 kHz — -0,001 to 0,001 · CMC 17·10⁻⁶ (abs.) 1 pF to 10 pF; 5 kHz to 10 kHz — -0,001 to 0,001 · CMC 42·10⁻⁶ (abs.) 1 pF to 10 pF; 10 kHz to 20 kHz — -0,001 to 0,001 · CMC 120·10⁻⁶ (abs.) 1 pF to 10 pF; 20 kHz to 100 kHz — -0,001 to 0,001 · CMC 150·10⁻⁶ (abs.) 1 pF to 10 pF; 100 kHz to 200 kHz — -0,001 to 0,001 · CMC 300·10⁻⁶ (abs.) 1 pF to 10 pF; 200 kHz to 500 kHz — -0,001 to 0,001 · CMC 450·10⁻⁶ (abs.) 1 pF to 10 pF; 500 kHz to 1 MHz — -0,001 to 0,001 · CMC 900·10⁻⁶ (abs.) 10 pF to 100 pF; 50 Hz to 200 Hz — -0,001 to 0,001 · CMC 13·10⁻⁶ (abs.) 10 pF to 100 pF; 200 Hz to 1 kHz — -0,001 to 0,001 · CMC 4·10⁻⁶ (abs.) 10 pF to 100 pF; 1 kHz — -0,001 to 0,001 · CMC 3·10⁻⁶ (abs.) 10 pF to 100 pF; 1 kHz to 5 kHz — -0,001 to 0,001 · CMC 9·10⁻⁶ (abs.) 10 pF to 100 pF; 5 kHz to 10 kHz — -0,001 to 0,001 · CMC 18·10⁻⁶ (abs.) 10 pF to 100 pF; 10 kHz to 20 kHz — -0,001 to 0,001 · CMC 39·10⁻⁶ (abs.) 10 pF to 100 pF; 20 kHz to 100 kHz — -0,001 to 0,001 · CMC 70·10⁻⁶ (abs.) 10 pF to 100 pF; 100 kHz to 200 kHz — -0,001 to 0,001 · CMC 150·10⁻⁶ (abs.) 10 pF to 100 pF; 200 kHz to 500 kHz — -0,001 to 0,001 · CMC 350·10⁻⁶ (abs.) 10 pF to 100 pF; 500 kHz to 1 MHz — -0,001 to 0,001 · CMC 700·10⁻⁶ (abs.) 100 pF to 1 000 pF; 50 Hz to 200 Hz — -0,001 to 0,001 · CMC 9·10⁻⁶ (abs.) 100 pF to 1 000 pF; 200 Hz to 1 kHz — -0,001 to 0,001 · CMC 4·10⁻⁶ (abs.) 100 pF to 1 000 pF; 1 kHz — -0,001 to 0,001 · CMC 3·10⁻⁶ (abs.) 100 pF to 1 000 pF; 1 kHz to 5 kHz — -0,001 to 0,001 · CMC 7·10⁻⁶ (abs.) 100 pF to 1 000 pF; 5 kHz to 10 kHz — -0,001 to 0,001 · CMC 12·10⁻⁶ (abs.) 100 pF to 1 000 pF; 10 kHz to 20 kHz — -0,001 to 0,001 · CMC 23·10⁻⁶ (abs.) 100 pF to 1 000 pF; 20 kHz to 100 kHz — -0,001 to 0,001 · CMC 70·10⁻⁶ (abs.) 100 pF to 1 000 pF; 100 kHz to 200 kHz — -0,001 to 0,001 · CMC 150·10⁻⁶ (abs.) 100 pF to 1 000 pF; 200 kHz to 500 kHz — -0,001 to 0,001 · CMC 350·10⁻⁶ (abs.) 100 pF to 1 000 pF; 500 kHz to 1 MHz — -0,001 to 0,001 · CMC 700·10⁻⁶ (abs.) 1 nF to 10 nF; 50 Hz to 200 Hz — -0,001 to 0,001 · CMC 79·10⁻⁶ (abs.) 1 nF to 10 nF; 200 Hz to 1 kHz — -0,001 to 0,001 · CMC 7·10⁻⁶ (abs.) 1 nF to 10 nF; 1 kHz — -0,001 to 0,001 · CMC 9·10⁻⁶ (abs.) 1 nF to 10 nF; 1 kHz to 5 kHz — -0,001 to 0,001 · CMC 24·10⁻⁶ (abs.) 1 nF to 10 nF; 5 kHz to 10 kHz — -0,001 to 0,001 · CMC 41·10⁻⁶ (abs.) 1 nF to 10 nF; 10 kHz to 20 kHz — -0,001 to 0,001 · CMC 79·10⁻⁶ (abs.) 1 nF to 10 nF; 20 kHz to 100 kHz — -0,001 to 0,001 · CMC 70·10⁻⁶ (abs.) 1 nF to 10 nF; 100 kHz to 200 kHz — -0,001 to 0,001 · CMC 150·10⁻⁶ (abs.) 1 nF to 10 nF; 200 kHz to 500 kHz — -0,001 to 0,001 · CMC 350·10⁻⁶ (abs.) 1 nF to 10 nF; 500 kHz to 1 MHz — -0,001 to 0,001 · CMC 700·10⁻⁶ (abs.) 1 pF to 10 pF; 50 Hz to 200 Hz — 0,001 to 0,01 · CMC 61·10⁻⁶ (abs.) 1 pF to 10 pF; 200 Hz to 1 kHz — 0,001 to 0,01 · CMC 18·10⁻⁶ (abs.) 1 pF to 10 pF; 1 kHz — 0,001 to 0,01 · CMC 5·10⁻⁶ (abs.) 1 pF to 10 pF; 1 kHz to 5 kHz — 0,001 to 0,01 · CMC 26·10⁻⁶ (abs.) 1 pF to 10 pF; 5 kHz to 10 kHz — 0,001 to 0,01 · CMC 50·10⁻⁶ (abs.) 1 pF to 10 pF; 10 kHz to 20 kHz — 0,001 to 0,01 · CMC 130·10⁻⁶ (abs.) 10 pF to 100 pF; 50 Hz to 200 Hz — 0,001 to 0,01 · CMC 20·10⁻⁶ (abs.) 10 pF to 100 pF; 200 Hz to 1 kHz — 0,001 to 0,01 · CMC 13·10⁻⁶ (abs.) 10 pF to 100 pF; 1 kHz — 0,001 to 0,01 · CMC 5·10⁻⁶ (abs.) 10 pF to 100 pF; 1 kHz to 5 kHz — 0,001 to 0,01 · CMC 15·10⁻⁶ (abs.) 10 pF to 100 pF; 5 kHz to 10 kHz — 0,001 to 0,01 · CMC 23·10⁻⁶ (abs.) 10 pF to 100 pF; 10 kHz to 20 kHz — 0,001 to 0,01 · CMC 43·10⁻⁶ (abs.) 100 pF to 1 000 pF; 50 Hz to 200 Hz — 0,001 to 0,01 · CMC 12·10⁻⁶ (abs.) 100 pF to 1 000 pF; 200 Hz to 1 kHz — 0,001 to 0,01 · CMC 7·10⁻⁶ (abs.) 100 pF to 1 000 pF; 1 kHz — 0,001 to 0,01 · CMC 5·10⁻⁶ (abs.) 100 pF to 1 000 pF; 1 kHz to 5 kHz — 0,001 to 0,01 · CMC 9·10⁻⁶ (abs.) 100 pF to 1 000 pF; 5 kHz to 10 kHz — 0,001 to 0,01 · CMC 14·10⁻⁶ (abs.) 100 pF to 1 000 pF; 10 kHz to 20 kHz — 0,001 to 0,01 · CMC 25·10⁻⁶ (abs.) 1 nF to 10 nF; 50 Hz to 200 Hz — 0,001 to 0,01 · CMC 82·10⁻⁶ (abs.) 1 nF to 10 nF; 200 Hz to 1 kHz — 0,001 to 0,01 · CMC 7·10⁻⁶ (abs.) 1 nF to 10 nF; 1 kHz — 0,001 to 0,01 · CMC 9·10⁻⁶ (abs.) 1 nF to 10 nF; 1 kHz to 5 kHz — 0,001 to 0,01 · CMC 24·10⁻⁶ (abs.) 1 nF to 10 nF; 5 kHz to 10 kHz — 0,001 to 0,01 · CMC 41·10⁻⁶ (abs.) 1 nF to 10 nF; 10 kHz to 20 kHz — 0,001 to 0,01 · CMC 79·10⁻⁶ (abs.) 1 pF to 10 pF; 50 Hz to 200 Hz — 0,01 to 0,1 · CMC 150·10⁻⁶ (abs.) 1 pF to 10 pF; 200 Hz to 1 kHz — 0,01 to 0,1 · CMC 120·10⁻⁶ (abs.) 1 pF to 10 pF; 1 kHz — 0,01 to 0,1 · CMC 30·10⁻⁶ (abs.) 1 pF to 10 pF; 1 kHz to 5 kHz — 0,01 to 0,1 · CMC 110·10⁻⁶ (abs.) 1 pF to 10 pF; 5 kHz to 10 kHz — 0,01 to 0,1 · CMC 130·10⁻⁶ (abs.) 10 pF to 100 pF; 50 Hz to 200 Hz — 0,01 to 0,1 · CMC 61·10⁻⁶ (abs.) 10 pF to 100 pF; 200 Hz to 1 kHz — 0,01 to 0,1 · CMC 52·10⁻⁶ (abs.) 10 pF to 100 pF; 1 kHz — 0,01 to 0,1 · CMC 30·10⁻⁶ (abs.) 10 pF to 100 pF; 1 kHz to 5 kHz — 0,01 to 0,1 · CMC 48·10⁻⁶ (abs.) 10 pF to 100 pF; 5 kHz to 10 kHz — 0,01 to 0,1 · CMC 58·10⁻⁶ (abs.) 100 pF to 1 000 pF; 50 Hz to 200 Hz — 0,01 to 0,1 · CMC 140·10⁻⁶ (abs.) 100 pF to 1 000 pF; 200 Hz to 1 kHz — 0,01 to 0,1 · CMC 74·10⁻⁶ (abs.) 100 pF to 1 000 pF; 1 kHz — 0,01 to 0,1 · CMC 30·10⁻⁶ (abs.) 100 pF to 1 000 pF; 1 kHz to 5 kHz — 0,01 to 0,1 · CMC 70·10⁻⁶ (abs.) 100 pF to 1 000 pF; 5 kHz to 10 kHz — 0,01 to 0,1 · CMC 61·10⁻⁶ (abs.) 1 nF to 10 nF; 50 Hz to 200 Hz — 0,01 to 0,1 · CMC 100·10⁻⁶ (abs.) 1 nF to 10 nF; 200 Hz to 1 kHz — 0,01 to 0,1 · CMC 7·10⁻⁶ (abs.) 1 nF to 10 nF; 1 kHz — 0,01 to 0,1 · CMC 9·10⁻⁶ (abs.) 1 nF to 10 nF; 1 kHz to 5 kHz — 0,01 to 0,1 · CMC 24·10⁻⁶ (abs.) 1 nF to 10 nF; 5 kHz to 10 kHz — 0,01 to 0,1 · CMC 41·10⁻⁶ (abs.) 1 nF to 10 nF; 10 kHz to 20 kHz — 0,01 to 0,1 · CMC 79·10⁻⁶ (abs.) 1 pF to 1 000 pF; 1 kHz — 0,1 to 1 · CMC 300·10⁻⁶ (abs.) 1 nF to 10 nF; 50 Hz to 200 Hz — 0,1 to 1 · CMC 100·10⁻⁶ (abs.) 1 nF to 10 nF; 200 Hz to 1 kHz — 0,1 to 1 · CMC 7·10⁻⁶ (abs.) 1 nF to 10 nF; 1 kHz — 0,1 to 1 · CMC 9·10⁻⁶ (abs.) 1 nF to 10 nF; 1 kHz to 5 kHz — 0,1 to 1 · CMC 24·10⁻⁶ (abs.) 1 nF to 10 nF; 5 kHz to 10 kHz — 0,1 to 1 · CMC 41·10⁻⁶ (abs.) 1 nF to 10 nF; 10 kHz to 20 kHz — 0,1 to 1 · CMC 79·10⁻⁶ (abs.) 10 nF to 100 nF; 50 Hz to 200 Hz — -1 to 1 · CMC 30·10⁻⁶ (abs.) 10 nF to 100 nF; 200 Hz to 1 kHz — -1 to 1 · CMC 15·10⁻⁶ (abs.) 10 nF to 100 nF; 1 kHz — -1 to 1 · CMC 15·10⁻⁶ (abs.) 10 nF to 100 nF; 1 kHz to 5 kHz — -1 to 1 · CMC 21·10⁻⁶ (abs.) 10 nF to 100 nF; 5 kHz to 10 kHz — -1 to 1 · CMC 30·10⁻⁶ (abs.) 10 nF to 100 nF; 10 kHz to 20 kHz — -1 to 1 · CMC 67·10⁻⁶ (abs.) 10 nF to 100 nF; 20 kHz to 100 kHz — -1 to 1 · CMC 70·10⁻⁶ (abs.) 10 nF to 100 nF; 100 kHz to 200 kHz — -1 to 1 · CMC 150·10⁻⁶ (abs.) 10 nF to 100 nF; 200 kHz to 500 kHz — -1 to 1 · CMC 350·10⁻⁶ (abs.) 10 nF to 100 nF; 500 kHz to 1 MHz — -1 to 1 · CMC 700·10⁻⁶ (abs.) 100 nF to 1 000 nF; 20 Hz to 50 Hz — -1 to 1 · CMC 100·10⁻⁶ (abs.) 100 nF to 1 000 nF; 50 Hz to 5 kHz — -1 to 1 · CMC 30·10⁻⁶ (abs.) 100 nF to 1 000 nF; 5 kHz to 10 kHz — -1 to 1 · CMC 60·10⁻⁶ (abs.) 100 nF to 1 000 nF; 10 kHz to 20 kHz — -1 to 1 · CMC 80·10⁻⁶ (abs.) 100 nF to 1 000 nF; 20 kHz to 100 kHz — -1 to 1 · CMC 90·10⁻⁶ (abs.) 100 nF to 1 000 nF; 100 kHz to 200 kHz — -1 to 1 · CMC 200·10⁻⁶ (abs.) 100 nF to 1 000 nF; 200 kHz to 500 kHz — -1 to 1 · CMC 450·10⁻⁶ (abs.) 100 nF to 1 000 nF; 500 kHz to 1 MHz — -1 to 1 · CMC 900·10⁻⁶ (abs.) 1 µF to 10 µF; 20 Hz to 50 Hz — -1 to 1 · CMC 100·10⁻⁶ (abs.) 1 µF to 10 µF; 50 Hz to 5 kHz — -1 to 1 · CMC 30·10⁻⁶ (abs.) 1 µF to 10 µF; 5 kHz to 10 kHz — -1 to 1 · CMC 60·10⁻⁶ (abs.) 1 µF to 10 µF; 10 kHz to 20 kHz — -1 to 1 · CMC 80·10⁻⁶ (abs.) 1 µF to 10 µF; 20 kHz to 100 kHz — -1 to 1 · CMC 120·10⁻⁶ (abs.) 10 µF to 100 µF; 20 Hz to 50 Hz — -1 to 1 · CMC 100·10⁻⁶ (abs.) 10 µF to 100 µF; 50 Hz to 200 Hz — -1 to 1 · CMC 30·10⁻⁶ (abs.) 10 µF to 100 µF; 200 Hz to 5 kHz — -1 to 1 · CMC 50·10⁻⁶ (abs.) 10 µF to 100 µF; 5 kHz to 10 kHz — -1 to 1 · CMC 100·10⁻⁶ (abs.) 10 µF to 100 µF; 10 kHz to 20 kHz — -1 to 1 · CMC 220·10⁻⁶ (abs.) 10 µF to 100 µF; 20 kHz to 100 kHz — -1 to 1 · CMC 500·10⁻⁶ (abs.) 100 µF to 1 000 µF; 20 Hz to 50 Hz — -1 to 1 · CMC 100·10⁻⁶ (abs.) 100 µF to 1 000 µF; 50 Hz to 1 kHz — -1 to 1 · CMC 50·10⁻⁶ (abs.) 100 µF to 1 000 µF; 1 kHz to 5 kHz — -1 to 1 · CMC 100·10⁻⁶ (abs.) 100 µF to 1 000 µF; 5 kHz to 10 kHz — -1 to 1 · CMC 160·10⁻⁶ (abs.) 100 µF to 1 000 µF; 10 kHz to 20 kHz — -1 to 1 · CMC 350·10⁻⁶ (abs.) 1 mF to 3 mF; 20 Hz to 50 Hz — -1 to 1 · CMC 100·10⁻⁶ (abs.) 1 mF to 3 mF; 50 Hz to 200 Hz — -1 to 1 · CMC 50·10⁻⁶ (abs.) 1 mF to 3 mF; 200 Hz to 5 kHz — -1 to 1 · CMC 100·10⁻⁶ (abs.) 3 mF to 10 mF; 20 Hz to 1 kHz — -1 to 1 · CMC 100·10⁻⁶ (abs.) CMC for the field of measured quantity: Electrical quantities |
Comparison with a standard using an impedance bridge | 611-MP-C030 611-MP-C041 | |
| 271 | AC resistance / AC resistance meters | Calibration – electrical quantities 1 mΩ to 10 mΩ; 20 Hz to 50 Hz — 1 mΩ to 10 mΩ · CMC 0,015 % 1 mΩ to 10 mΩ; 50 Hz to 20 kHz — 1 mΩ to 10 mΩ · CMC 0,010 % 1 mΩ to 10 mΩ; 20 kHz to 100 kHz — 1 mΩ to 10 mΩ · CMC 0,015 % 20 Hz to 50 Hz — 10 mΩ to 100 mΩ · CMC 0,010 % 50 Hz to 100 kHz — 10 mΩ to 100 mΩ · CMC 0,0070 % 100 kHz to 1 MHz — 10 mΩ to 100 mΩ · CMC 0,10 % 20 Hz to 50 Hz — 100 mΩ to 1 Ω · CMC 0,0070 % 50 Hz to 100 kHz — 100 mΩ to 1 Ω · CMC 0,0050 % 100 kHz to 200 kHz — 100 mΩ to 1 Ω · CMC 0,0070 % 200 kHz to 500 kHz — 100 mΩ to 1 Ω · CMC 0,015 % 500 kHz to 1 MHz — 100 mΩ to 1 Ω · CMC 0,025 % 20 Hz to 20 kHz — 1 Ω to 10 kΩ · CMC 0,0020 % 20 kHz to 200 kHz — 1 Ω to 10 kΩ · CMC 0,0050 % 200 kHz to 500 kHz — 1 Ω to 10 kΩ · CMC 0,010 % 500 kHz to 1 MHz — 1 Ω to 10 kΩ · CMC 0,015 % 1 MHz to 10 MHz — 1 Ω to 10 kΩ · CMC 0,20 % 20 Hz to 50 Hz — 10 kΩ to 100 kΩ · CMC 0,0070 % 50 Hz to 20 kHz — 10 kΩ to 100 kΩ · CMC 0,0050 % 20 kHz to 100 kHz — 10 kΩ to 100 kΩ · CMC 0,0070 % 100 kHz to 200 kHz — 10 kΩ to 100 kΩ · CMC 0,010 % 200 kHz to 500 kHz — 10 kΩ to 100 kΩ · CMC 0,015 % 500 kHz to 1 MHz — 10 kΩ to 100 kΩ · CMC 0,025 % 1 MHz to 10 MHz — 10 kΩ to 100 kΩ · CMC 5,0 % 20 Hz to 50 Hz — 100 kΩ to 1 MΩ · CMC 0,015 % 50 Hz to 20 kHz — 100 kΩ to 1 MΩ · CMC 0,0080 % 20 kHz to 100 kHz — 100 kΩ to 1 MΩ · CMC 0,020 % 100 kHz to 1 MHz — 100 kΩ to 1 MΩ · CMC 0,10 % 1 MHz to 10 MHz — 100 kΩ to 1 MΩ · CMC 5,0 % 20 Hz to 50 Hz — 1 MΩ to 10 MΩ · CMC 0,030 % 50 Hz to 20 kHz — 1 MΩ to 10 MΩ · CMC 0,015 % 20 kHz to 1 MHz — 1 MΩ to 10 MΩ · CMC 0,30 % 20 Hz to 50 Hz — 10 MΩ to 100 MΩ · CMC 0,070 % 50 Hz to 5 kHz — 10 MΩ to 100 MΩ · CMC 0,030 % 5 kHz to 10 kHz — 10 MΩ to 100 MΩ · CMC 0,050 % 10 kHz to 100 kHz — 10 MΩ to 100 MΩ · CMC 0,30 % CMC for the field of measured quantity: Electrical quantities |
Comparison with a standard using an impedance bridge | 611-MP-C040, 611-MP-C041 | |
| 272 | Secondary component of impedance Z expressed as phase angle φ / AC resistance meters | Calibration – electrical quantities 1 mΩ to 10 mΩ; 20 Hz to 200 Hz — -π to +π · CMC 3,5 µrad 1 mΩ to 10 mΩ; 200 Hz to 1 kHz — -π to +π · CMC 17·f⁴ µrad 1 mΩ to 10 mΩ; 1 kHz to 100 kHz — -π to +π · CMC 17·f µrad 10 mΩ to 100 mΩ; 20 Hz to 1 kHz — -π to +π · CMC 2,5 µrad 10 mΩ to 100 mΩ; 1 kHz to 100 kHz — -π to +π · CMC 4·f µrad 100 mΩ to 500 mΩ; 20 Hz to 1 kHz — -π to +π · CMC 1,5 µrad 100 mΩ to 500 mΩ; 1 kHz to 1 MHz — -π to +π · CMC 1,5·f µrad 500 mΩ to 1 Ω; 20 Hz to 1 kHz — -π to +π · CMC 1,0 µrad 500 mΩ to 1 Ω; 1 kHz to 1 MHz — -π to +π · CMC 0,9·f µrad 1 Ω to 1 kΩ; 20 Hz to 1 kHz — -π to +π · CMC 0,7 µrad 1 Ω to 1 kΩ; 1 kHz to 1 MHz — -π to +π · CMC 0,7·f µrad 1 kΩ to 10 kΩ; 20 Hz to 1 kHz — -π to +π · CMC 0,9 µrad 1 kΩ to 10 kΩ; 1 kHz to 1MHz — -π to +π · CMC 0,9·f µrad 10 kΩ to 100 kΩ; 20 Hz to 1 kHz — -π to +π · CMC 1,2 µrad 10 kΩ to 100 kΩ; 1 kHz to 1 MHz — -π to +π · CMC 1,2·f µrad 100 kΩ to 10 MΩ; 50 Hz to 200 Hz — -π to +π · CMC 50 µrad 100 kΩ to 10 MΩ; 200 Hz to 5 kHz — -π to +π · CMC 8,0 µrad 100 kΩ to 10 MΩ; 5 kHz to 10 kHz — -π to +π · CMC 20 µrad 100 kΩ to 10 MΩ; 10 kHz to 20 kHz — -π to +π · CMC 30 µrad 100 kΩ to 10 MΩ; 20 kHz to 100 kHz — -π to +π · CMC 1,2·f µrad CMC for the field of measured quantity: Electrical quantities |
Comparison with a standard using an impedance bridge | 611-MP-C040 611-MP-C041 611-MP-C099 | |
| 273 | Inductance / Inductance meters | Calibration – electrical quantities 1 kHz — 10 mH · CMC 0,15 µH 1 kHz — 100 mH · CMC 1,5 µH 1 kHz to 10 kHz — 1 µH to 10 µH · CMC 0,10 % 10 kHz to 20 kHz — 1 µH to 10 µH · CMC 0,050 % 20 kHz to 100 kHz — 1 µH to 10 µH · CMC 0,020 % 100 kHz to 1 MHz — 1 µH to 10 µH · CMC 0,050 % 50 Hz to 200 Hz — 10 µH to 100 µH · CMC 0,10 % 200 Hz to 1 kHz — 10 µH to 100 µH · CMC 0,015 % 1 kHz to 20 kHz — 10 µH to 100 µH · CMC 0,020 % 20 kHz to 100 kHz — 10 µH to 100 µH · CMC 0,015 % 100 kHz to 1 MHz — 10 µH to 100 µH · CMC 0,050 % 20 Hz to 50 Hz — 100 µH to 1 mH · CMC 0,30 % 50 Hz to 1 kHz — 100 µH to 1 mH · CMC 0,015 % 1 kHz to 100 kHz — 100 µH to 1 mH · CMC 0,010 % 100 kHz to 1 MHz — 100 µH to 1 mH · CMC 0,050 % 20 Hz to 50 Hz — 1 mH to 10 mH · CMC 0,30 % 50 Hz to 200 Hz — 1 mH to 10 mH · CMC 0,015 % 200 Hz to 1 kHz — 1 mH to 10 mH · CMC 0,0080 % 1 kHz — 1 mH to 10 mH · CMC 0,0050 % 1 kHz to 20 kHz — 1 mH to 10 mH · CMC 0,0080 % 20 kHz to 100 kHz — 1 mH to 10 mH · CMC 0,015 % 100 kHz to 1 MHz — 1 mH to 10 mH · CMC 0,050 % 20 Hz to 50 Hz — 10 mH to 100 mH · CMC 0,30 % 50 Hz to 1 kHz — 10 mH to 100 mH · CMC 0,0080 % 1 kHz — 10 mH to 100 mH · CMC 0,0050 % 1 kHz to 20 kHz — 10 mH to 100 mH · CMC 0,015 % 20 kHz to 100 kHz — 10 mH to 100 mH · CMC 0,030 % 100 kHz to 1 MHz — 10 mH to 100 mH · CMC 0,050 % 50 Hz to 1 kHz — 100 mH to 1 H · CMC 0,0080 % 1 kHz — 100 mH to 1 H · CMC 0,0050 % 1 kHz to 10 kHz — 100 mH to 1 H · CMC 0,020 % 10 kHz to 100 kHz — 100 mH to 1 H · CMC 0,050 % 20 Hz to 50 Hz — 1 H to 10 H · CMC 0,30 % 50 Hz to 1 kHz — 1 H to 10 H · CMC 0,020 % 1 kHz to 1 MHz — 1 H to 10 H · CMC 0,050 % 20 Hz to 50 Hz — 10 H to 100 H · CMC 0,30 % 50 Hz to 1 kHz — 10 H to 100 H · CMC 0,030 % 1 kHz to 100 kHz — 10 H to 100 H · CMC 0,050 % 20 Hz to 50 Hz — 100 H to 1 kH · CMC 0,30 % 50 Hz to 10 kHz — 100 H to 1 kH · CMC 0,10 % CMC for the field of measured quantity: Electrical quantities |
Comparison with a standard using an impedance bridge | 611-MP-C099 611-MP-C041 | |
| 274 | Digital electrical inspection instruments and related standards / insulation resistance | Calibration – electrical quantities od 10 kΩ do 10 MΩ · CMC 0,0012 % from 10 MΩ to 100 MΩ · CMC 0,0020 % from 100 MΩ to 1 GΩ · CMC 0,010 % from 1 GΩ to 10 GΩ · CMC 0,025 % from 10 GΩ to 100 GΩ · CMC 0,050 % from 100 GΩ to 1 TΩ · CMC 0,002·R² + 0,001·R (Pozn. 5) 100 MΩ · CMC 0,0017 % 1 GΩ · CMC 0,0030 % 10 GΩ · CMC 0,010 % CMC for the field of measured quantity: Electrical quantities |
Indirect measurement using a voltage calibrator, reference resistor and voltmeter | 131-MP-C006 | |
| 275 | Digital electrical inspection instruments and related standards / insulation resistance | Calibration – electrical quantities od 10 kΩ do 1 GΩ · CMC 0,020 % from 1 GΩ to 10 GΩ · CMC 1,0 % from 10 GΩ to 100 GΩ · CMC 1,5 % from 100 GΩ to 1 TΩ · CMC 2,5 % from 1 TΩ to 10 TΩ · CMC 4,0 % 100 MΩ · CMC 0,0030 % 1 GΩ · CMC 0,0050 % 10 GΩ · CMC 0,020 % 100 GΩ · CMC 0,10 % 1 TΩ · CMC 0,50 % CMC for the field of measured quantity: Electrical quantities |
Direct generation of resistance by an inspection instrument calibrator, resistance decade or resistance standards | 131-MP-C006 | |
| 276 | Digital electrical inspection instruments and related standards / protective loop, line impedance and earth loop | Calibration – electrical quantities 25 mΩ · CMC 5,0 mΩ 50 mΩ · CMC 5,0 mΩ 100 mΩ · CMC 5,0 mΩ 330 mΩ · CMC 7,0 mΩ 500 mΩ · CMC 8,0 mΩ 1 Ω · CMC 10 mΩ 1,8 Ω · CMC 18 mΩ 5 Ω · CMC 30 mΩ 10 Ω · CMC 60 mΩ 18 Ω · CMC 100 mΩ 50 Ω · CMC 300 mΩ 100 Ω · CMC 500 mΩ 180 Ω · CMC 1,0 Ω 500 Ω · CMC 2,5 Ω 1 kΩ · CMC 5,0 Ω 1,8 kΩ · CMC 10 Ω CMC for the field of measured quantity: Electrical quantities |
Direct generation of resistance by an inspection instrument calibrator, resistance decade or resistance standards | 131-MP-C006 | |
| 277 | Digital electrical inspection instruments and related standards / tripping current of residual current devices | Calibration – electrical quantities 50 Hz — 3 mA to 3 A · CMC 0,20 % 50 Hz — 3 mA to 3 A · CMC 1,0 % CMC for the field of measured quantity: Electrical quantities |
Simulation of a residual current device and direct measurement of the tripping current by an inspection instrument calibrator | 131-MP-C006 | |
| 278 | Digital electrical inspection instruments and related standards / tripping time of residual current devices | Calibration – electrical quantities 50 Hz — 10 ms to 5 s · CMC 0,05 ms 50 Hz — 10 ms to 5 s · CMC 0,020 % + 0,25 ms CMC for the field of measured quantity: Electrical quantities |
Simulation of a residual current device and direct measurement of the tripping time by an inspection instrument calibrator | 131-MP-C006 | |
| 279 | Digital electrical inspection instruments and related standards / passive leakage current | Calibration – electrical quantities 50 Hz — 0,1 mA to 30 mA · CMC 0,30 % + 2 µA CMC for the field of measured quantity: Electrical quantities |
Direct comparison with an inspection instrument calibrator | 131-MP-C006 | |
| 280 | Digital electrical inspection instruments and related standards / differential leakage current | Calibration – electrical quantities 50 Hz — 0,1 mA to 30 mA · CMC 0,30 % + 2 µA CMC for the field of measured quantity: Electrical quantities |
Direct comparison with an inspection instrument calibrator | 131-MP-C006 | |
| 281 | Digital electrical inspection instruments and related standards / substitute leakage current | Calibration – electrical quantities 50 Hz — 0,1 mA to 30 mA · CMC 0,30 % + 2 µA CMC for the field of measured quantity: Electrical quantities |
Direct comparison with an inspection instrument calibrator | 131-MP-C006 | |
| 282 | Digital electrical inspection instruments and related standards / active leakage current | Calibration – electrical quantities 50 Hz — 0,1 mA to 30 mA · CMC 0,30 % + 1 µA DC + 20 Hz to 400 Hz — 0,1 mA to 300 mA · CMC 0,20 % CMC for the field of measured quantity: Electrical quantities |
Direct comparison with an inspection instrument calibrator | 131-MP-C006 | |
| 283 | Digital electrical inspection instruments and related standards / DC voltage | Calibration – electrical quantities 0 V to 10 kV · CMC 0,30 % + 5 V CMC for the field of measured quantity: Electrical quantities |
Direct measurement of high voltage using an inspection instrument calibrator or a voltmeter and voltage probe | 131-MP-C006 | |
| 284 | Digital electrical inspection instruments and related standards / AC voltage | Calibration – electrical quantities 50 Hz — 0 V to 10 kV · CMC 0,50 % + 5 V CMC for the field of measured quantity: Electrical quantities |
Direct measurement of high voltage using an inspection instrument calibrator or a voltmeter and voltage probe | 131-MP-C006 | |
| 285 | Digital electrical inspection instruments and related standards / DC current | Calibration – electrical quantities Current clamps — 1 A to 1 kA · CMC 0,80 % CMC for the field of measured quantity: Electrical quantities |
Current simulation by a calibrator and current coil | 131-MP-C006 | |
| 286 | Digital electrical inspection instruments and related standards / AC current | Calibration – electrical quantities Current clamps; 50 Hz — 1 A to 1 kA · CMC 0,50 % CMC for the field of measured quantity: Electrical quantities |
Current simulation by a calibrator and current coil | 131-MP-C006 | |
| 287 | Frequency / signal sources, frequency meters | Calibration – time and frequency quantities 0,01 Hz to 3 GHz · CMC 1·10⁻¹¹ CMC for the field of measured quantity: Time and frequency quantities |
Measurement by a standard counter, direct comparison with a standard, alternatively using frequency dividers | 113-MP-C007 | |
| 288 | Period / signal sources, time interval meters | Calibration – time and frequency quantities from 5 ns to 10⁵ s · CMC 1·10⁻¹¹ CMC for the field of measured quantity: Time and frequency quantities |
Measurement by a standard counter, direct comparison with a standard | 113-MP-C007 | |
| 289 | Time interval / signal sources, time interval meters, | Calibration – time and frequency quantities 0 s to 10⁵ s · CMC (1,1·10⁻⁹ +1·10⁻¹¹ t) s CMC for the field of measured quantity: Time and frequency quantities |
Measurement by a counter | 113-MP-C007 | |
| 290 | Time interval / signal sources, time interval meters, | Calibration – time and frequency quantities 0 s to 10 s · CMC (10·10⁻¹² +2·10⁻³ t) s CMC for the field of measured quantity: Time and frequency quantities |
Measurement by an oscilloscope | 113-MP-C007 | |
| 291 | Simple pulse counting / pulse sources, pulse counters | Calibration – time and frequency quantities fmax= 50 MHz — 0 to 1·10⁷ · CMC 0 CMC for the field of measured quantity: Time and frequency quantities |
Measurement by a standard counter, direct comparison with a standard | 113-MP-C007 | |
| 292 | Time interval / mechanically operated stopwatches | Calibration – time and frequency quantities 0,1 s to 35 999,99 s · CMC 16 ms CMC for the field of measured quantity: Time and frequency quantities |
Direct comparison with a standard | 113-MP-C013 | |
| 293 | Relative frequency error of the time base / stopwatches with LCD | Calibration – time and frequency quantities -1·10⁻³ to 1·10⁻³ · CMC 3·10⁻⁷ CMC for the field of measured quantity: Time and frequency quantities |
Frequency measurement - capacitive coupling to the LCD | 113-MP-C013 | |
| 294 | Kinematic viscosity / flow time | Calibration – physicochemical quantities Flow cup with nozzle D4 — 30 s to 100 s · CMC 0,91 s Flow cup with nozzle C3 — 30 s to 100 s · CMC 0,83 s Flow cup with nozzle C4 — 30 s to 100 s · CMC 0,72 s Flow cup with nozzle C5 — 30 s to 100 s · CMC 0,56 s Flow cup with nozzle C6 — 30 s to 100 s · CMC 0,84 s Flow cup with nozzle A4 — 30 s to 100 s · CMC 0,47 s CMC for the field of measured quantity: Physicochemical quantities |
Comparison with a calibration liquid | 616-MP-C001 | |
| 295 | Kinematic viscosity / capillary viscometer constant | Calibration – physicochemical quantities 0,001 mm²·s⁻² · CMC 1,8·10⁻⁶ mm²·s⁻¹ 0,003 mm²·s⁻² · CMC 7,6·10⁻⁶ mm²·s⁻¹ 0,01 mm²·s⁻² · CMC 2,9·10⁻⁵ mm²·s⁻¹ 0,03 mm²·s⁻² · CMC 9,7·10⁻⁵ mm²·s⁻¹ 0,1 mm²·s⁻² · CMC 3,5·10⁻⁴ mm²·s⁻¹ 0,3 mm²·s⁻² · CMC 1,1·10⁻³ mm²·s⁻¹ 1 mm²·s⁻² · CMC 3,9·10⁻³ mm²·s⁻¹ 3 mm²·s⁻² · CMC 1,7·10⁻² mm²·s⁻¹ 10 mm²·s⁻² · CMC 5,0·10⁻² mm²·s⁻¹ 30 mm²·s⁻² · CMC 1,6·10⁻¹ mm²·s⁻¹ CMC for the field of measured quantity: Physicochemical quantities |
Comparison with a standard viscometer | 616-MP-C002 | |
| 296 | Kinematic viscosity / calibration liquids | Calibration – physicochemical quantities 0,6 mm²·s⁻¹ to 6 mm²·s⁻¹ · CMC 0,21 % 6 mm²·s⁻¹ to 60 mm²·s⁻¹ · CMC 0,32 % 60 mm²·s⁻¹ to 600 mm²·s⁻¹ · CMC 0,35 % 600 mm²·s⁻¹ to 6 000 mm²·s⁻¹ · CMC 0,42 % 6 000 mm²·s⁻¹ to 30 000 mm²·s⁻¹ · CMC 0,52 % CMC for the field of measured quantity: Physicochemical quantities |
Direct measurement by a standard viscometer | 616-MP-C002 | |
| 297 | Dynamic viscosity / calibration liquids | Calibration – physicochemical quantities 0,6 mPa·s to 6 mPa·s · CMC 0,21 % 6 mPa·s to 60 mPa·s · CMC 0,32 % 60 mPa·s to 600 mPa·s · CMC 0,35 % 600 mPa·s to 6 000 mPa·s · CMC 0,42 % 6 000 mPa·s to 30 000 mPa·s · CMC 0,52 % CMC for the field of measured quantity: Physicochemical quantities |
Direct measurement by a standard viscometer and a standard hydrometer | 616-MP-C002 | |
| 298 | Dynamic viscosity / rotational viscometers | Calibration – physicochemical quantities 10 mPa·s to 150 mPa·s · CMC 0,91 % 150 mPa·s to 400 mPa·s · CMC 0,92 % 400 mPa·s to 1 300 mPa·s · CMC 1,1 % 1 300 mPa·s to 30 000 mPa·s · CMC 1,4 % CMC for the field of measured quantity: Physicochemical quantities |
Comparison with a calibration liquid | 616-MP-C003 | |
| 299 | Density of liquids / glass hydrometers | Calibration – physicochemical quantities od 620 kg·m⁻³ do 1 850 kg·m⁻³ · CMC 0,022 kg·m⁻³ from 0 % vol. to 100 % vol. · CMC 0,019 % obj. od 0 % hm. do 90 % hm. · CMC 0,019 % hm. od 10 kg·hl⁻¹ do 30 kg·hl⁻¹ · CMC 0,019 kg·hl⁻¹ CMC for the field of measured quantity: Physicochemical quantities |
Comparison with a standard hydrometer | 616-MP-C004 | |
| 300 | Conductivity meters | Calibration – physicochemical quantities 0,005 S·m⁻¹ to 0,015 S·m⁻¹ · CMC od 5,6 % do 0,64 % 0,015 S·m⁻¹ to 0,15 S·m⁻¹ · CMC od 0,64 % do 0,19 % 0,15 S·m⁻¹ to 1,5 S·m⁻¹ · CMC od 0,19 % do 1,5 % 1,5 S·m⁻¹ to 10 S·m⁻¹ · CMC 1,5 % CMC for the field of measured quantity: Physicochemical quantities |
Comparison with a standard conductivity meter | 616-MP-C005 | |
| Primary Metrology Laboratories Praha | |||||
| 301 | Length measuring instruments and gauges | Calibration – length from 0 m to 20 m · CMC (0,4L +0,02) µm CMC for the field of measured quantity: Length |
Direct measurement by a laser interferometer | 614-MP-C006 | |
| 302 | Gauges, standards, artefacts | Calibration – length 0 mm to 2 550 mm · CMC Q[0,09; 0,4L] µm CMC for the field of measured quantity: Length |
Measurement on a coordinate measuring machine | 815-MP-C503 | |
| 303 | Coordinate measuring machine / system | Calibration – length tactile — 0 m to 6 m · CMC Q[0,01;0,2L] µm optical — 0 m to 3 m · CMC Q[0,01;0,2L] µm multisensor — 0 m to 3 m · CMC Q[0,01;0,2L] µm optical 3D — 0 m to 3 m · CMC Q[0,3;1L] µm articulated arm — 0 m to 4,5 m · CMC Q[0,3;1L] µm computer tomography — 0 m to 1,5 m · CMC Q[0,3;1L] µm laser-trackers — 0 m to 30 m · CMC Q[0,3;1L] µm CMC for the field of measured quantity: Length |
Comparison with the standard | 815-MP-C501 | |
| 304 | Tape measures, length and distance gauges | Calibration – length od 0,3 m do 30 m · CMC Q[100; 3L] µm from 0 m to 300 m · CMC Q[20; 20L] µm CMC for the field of measured quantity: Length |
Comparison using a tape measure, micrometer head | 815-MP-C510 | |
| 305 | Roughness / setting standard | Calibration – length Pt — 0,01 µm to 1 µm · CMC Q[20; 50Pt] nm Pt — 1 µm to 100 µm · CMC Q[20; 20Pt] nm geometrical standard type C; Ra, Rq, Rpm, Rk profiles, material ratios, Rsk, Rp3z, Rku, Rc, Rdq, Rδc — 0,01 µm to 100 µm · CMC Q[10; 30Ra] nm geometrical standard type C; Rmax, RzISO, Rp, Rv, Rz, Rt, Rz1, Rz2, Rz3, Rz4, Rz5 — 0,01 µm to 100 µm · CMC Q[20; 40Rp] nm geometrical standard type D; Ra, Rq, Rpm, Rk profiles, material ratios, Rsk, Rp3z, Rku, Rc, Rdq, Rδc — 0,01 µm to 100 µm · CMC Q[10; 40Ra] nm geometrical standard type D; Rmax, RzISO, Rp, Rv, Rz, Rt, Rz1, Rz2, Rz3, Rz4, Rz5 — 0,01 µm to 100 µm · CMC Q[20; 50Rp] nm geometrical standard type C and D; Horizontal characteristics — 0,01 µm to 1 µm · CMC Q[20; 50Sm] nm CMC for the field of measured quantity: Length |
Contact measurement | 813-MP-C306 | |
| 306 | Roughness meter for setting standards | Calibration – length All characteristics — 0,01 µm to 1 µm · CMC 3,4 % All characteristics — 1 µm to 6 000 µm · CMC 1,2 % CMC for the field of measured quantity: Length |
Contact measurement | 813-MP-C306 | |
| 307 | Roughness meter for geometrical standards | Calibration – length All characteristics — 1 µm to 6 000 µm · CMC 3,4 % CMC for the field of measured quantity: Length |
Contact measurement | 813-MP-C306 | |
| 308 | Linear thermal expansion / gauge blocks to 100 mm | Calibration – length At a temperature difference of 4 °C or more — 0,1 µm·m⁻¹·K⁻¹ to 100 µm·m⁻¹·K⁻¹ · CMC 0,29 µm·m⁻¹·K⁻¹ At a temperature difference of 3 °C or more — 0,1 µm·m⁻¹·K⁻¹ to 100 µm·m⁻¹·K⁻¹ · CMC 0,35 µm·m⁻¹·K⁻¹ At a temperature difference of 2 °C or more — 0,1 µm·m⁻¹·K⁻¹ to 100 µm·m⁻¹·K⁻¹ · CMC 0,49 µm·m⁻¹·K⁻¹ At a temperature difference of 1 °C or more — 0,1 µm·m⁻¹·K⁻¹ to 100 µm·m⁻¹·K⁻¹ · CMC 0,95 µm·m⁻¹·K⁻¹ CMC for the field of measured quantity: Length |
Measurement of length change at a defined temperature change | 411-MP-C010 | |
| 309 | Acceleration of linear harmonic mechanical vibrations / vibration sensors | Calibration – mechanical motion 0.1 Hz to 5 kHz — 0,01 m·s⁻² to 400 m·s⁻² · CMC 1,0 % 5 to 20 kHz — 0,01 m·s⁻² to 400 m·s⁻² · CMC 1,5 % CMC for the field of measured quantity: Mechanical motion |
Comparison with a standard sensor | 812-MP-C207 | |
| 310 | Sensitivity of vibration sensors / vibration transducers | Calibration – mechanical motion 0.1 Hz to 5 kHz — 0,01 pC/m·s⁻² to 1 000 pC/m·s⁻² · CMC 1,0 % 5 to 20 kHz — 0,01 pC/m·s⁻² to 1 000 pC/m·s⁻² · CMC 1,5 % 0.1 Hz to 5 kHz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 1,0 % 5 to 20 kHz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 1,5 % 0.1 Hz to 5 kHz — 0,1 mV/m·s⁻¹ to 10 000 mV/m·s⁻¹ · CMC 1,0 % 5 to 20 kHz — 0,1 mV/m·s⁻¹ to 10 000 mV/m·s⁻¹ · CMC 1,5 % CMC for the field of measured quantity: Mechanical motion |
Comparison with a standard sensor | 812-MP-C207 | |
| 311 | Transmission / amplifiers and filters | Calibration – mechanical motion 0.1 Hz to 100 kHz — 10⁻⁷ V/V to 10⁷ V/V · CMC 0,5 % nebo⁶ 0,1 dB 0.1 Hz to 100 kHz — 0,001 mV/pC to 1 000 mV/pC · CMC 0,5 % nebo⁶ 0,1 dB CMC for the field of measured quantity: Mechanical motion |
By simulated electrical signal | 812-MP-C207 | |
| 312 | Acceleration / vibrometers without a sensor | Calibration – mechanical motion 0.1 Hz to 100 kHz — 0,01 m·s⁻² to 10 000 m·s⁻² · CMC 0,5 % CMC for the field of measured quantity: Mechanical motion |
By simulated electrical signal | 812-MP-C207 | |
| 313 | Velocity / vibrometers without a sensor | Calibration – mechanical motion 0.1 Hz to 100 kHz — 0,01 m·s⁻¹ to 1 000 mm·s⁻¹ · CMC 0,5 % CMC for the field of measured quantity: Mechanical motion |
By simulated electrical signal | 812-MP-C207 | |
| 314 | Maximum value of half-sine wave mechanical shock / acceleration sensors | Calibration – mechanical motion 1 m·s⁻² to 100 000 m·s⁻² · CMC 1,2 % CMC for the field of measured quantity: Mechanical motion |
Comparison with a standard sensor | 812-MP-C208 | |
| 315 | Vibration frequency | Calibration – mechanical motion 0,1 Hz to 10 kHz · CMC 0,01 % CMC for the field of measured quantity: Mechanical motion |
Measurement using a counter | 812-MP-C207 812-MP-C210 | |
| 316 | Revolution – impulse generators and meters | Calibration – mechanical motion 0,01 min⁻¹ to 100 000 min⁻¹ · CMC 1 % CMC for the field of measured quantity: Mechanical motion |
Contact method | 812-MP-C212 | |
| 317 | Revolution – impulse generators and meters | Calibration – mechanical motion 0,1 s⁻¹ to 10 000 000 s⁻¹ · CMC 10⁻¹⁰ CMC for the field of measured quantity: Mechanical motion |
Contactless method | 812-MP-C212 | |
| 318 | Linear motion velocity / velocity meters for mechanical parts | Calibration – mechanical motion 0,01 mm·s⁻¹ to 1 000 m·s⁻¹ · CMC 0,01 % CMC for the field of measured quantity: Mechanical motion |
Measurement of time and distance using an electric, optoelectronic or electronic delay line | 812-MP-C201 | |
| 319 | Linear motion acceleration / acceleration meters for mechanical parts | Calibration – mechanical motion -200 m·s⁻² to 200 m·s⁻² · CMC 0,01 % CMC for the field of measured quantity: Mechanical motion |
Measurement of time and distance using an electric, optoelectronic or electronic delay line | 812-MP-C201 | |
| 320 | Force / force-proving instruments | Calibration – force, mechanical tests 0,2 N to 1 N · CMC 0,0002 1 N to 20 kN · CMC 0,000 04 20 kN to 1 MN · CMC 0,000 2 CMC for the field of measured quantity: Force, mechanical tests |
Calibration using a standard instrument or by suspending weights (ČSN EN ISO 376) | 811-MP-C101 | |
| 321 | Torque / torque measuring instruments | Calibration – force, mechanical tests 0,02 N·m to 0,2 N·m · CMC 0,001 0,2 N·m to 1 N·m · CMC 0,000 09 1 N·m to 100 N·m · CMC 0,000 08 100 N·m to 1 kN·m · CMC 0,000 1 1 kN·m to 10 kN·m · CMC 0,000 4 CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a standard torque measuring instrument, torque transmission standard (torque sensor) or using weights and torque arms | 811-MP-C102 | |
| 322 | Torque / torque wrenches | Calibration – force, mechanical tests 0,02 N·m to 3 kN·m · CMC 0,005 CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a torque transmission standard (torque sensor) (ČSN EN ISO 6789-1, ČSN EN ISO 6789-2) | 811-MP-C103 | |
| 323 | Torque / equipment for the calibration of torque wrenches | Calibration – force, mechanical tests 0,02 N·m to 500 N·m · CMC 0,001 500 N·m to 10 kN·m · CMC 0,000 4 CMC for the field of measured quantity: Force, mechanical tests |
Calibration by reference torque wrench, torque transmission standard (torque sensor) or by means of weights and torque arms | 811-MP-C104 | |
| 324 | Hardness plates and products | Calibration – force, mechanical tests Rockwell A — 10 HRA to 100 HRA · CMC 0,2 HR Rockwell B — 10 HRB to 110 HRB · CMC 0,2 HR Rockwell C — 10 HRC to 80 HRC · CMC 0,2 HR Rockwell D — 10 HRD to 90 HRD · CMC 0,2 HR Rockwell E — 10 HREW to 110 HREW · CMC 0,2 HR Rockwell F — 10 HRFW to 110 HRFW · CMC 0,2 HR Rockwell G — 10 HRGW to 100 HRGW · CMC 0,2 HR Rockwell H — 10 HRHW to 110 HRHW · CMC 0,2 HR Rockwell K — 6 HRKW to 110 HRKW · CMC 0,2 HR Rockwell 15N — 10 HR15N to 100 HR15N · CMC 0,26 HR Rockwell 30N — 10 HR30N to 100 HR30N · CMC 0,26 HR Rockwell 45N — 10 HR45N to 90 HR45N · CMC 0,26 HR Rockwell 15T — 10 HR15TW to 100 HR15TW · CMC 0,26 HR Rockwell 30T — 10 HR30TW to 90 HR30TW · CMC 0,26 HR Rockwell 45T — 6 HR45TW to 80 HR45TW · CMC 0,26 HR CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN ISO 6508-3, ASTM E18 | 813-MP-C301 | |
| 325 | Hardness plates and products | Calibration – force, mechanical tests Vickers HV0.01 to HV0.5 — 20 HV to 3 000 HV · CMC 0,59 % HV0.5 to HV1 — 20 HV to 3 000 HV · CMC 0,51 % HV1 to HV5 — 20 HV to 3 000 HV · CMC 0,44 % HV5 to HV10 — 20 HV to 3 000 HV · CMC 0,44 % HV10 to HV30 — 20 HV to 3 000 HV · CMC 0,38 % HV30 to HV50 — 20 HV to 3 000 HV · CMC 0,36 % HV50 and more — 20 HV to 3 000 HV · CMC 0,34 % CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN ISO 6507-3, ASTM E384 | 813-MP-C301 | |
| 326 | Hardness plates and products | Calibration – force, mechanical tests Brinell scale with 2.5mm and 1mm balls — 20 HBW to 650 HBW · CMC 0,24 % Scale with a 5mm ball — 20 HBW to 650 HBW · CMC 0,20 % Scale with a 10 mm ball — 20 HBW to 650 HBW · CMC 0,20 % CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN ISO 6506-3, ASTM E10 | 813-MP-C301 | |
| 327 | Hardness plates and products | Calibration – force, mechanical tests Shore — 1 ShA to 110 ShA · CMC 0,26 Sh IRHD N, H, L — 1 °IRHD to 110 °IRHD · CMC 0,44 °IRHD IRHD M — 1 °IRHD to 110 °IRHD · CMC 0,70 °IRHD CMC for the field of measured quantity: Force, mechanical tests |
Direct measurement using a standard hardness tester | 813-MP-C308 | |
| 328 | Rockwell penetrating bodies | Calibration – force, mechanical tests cone angle — 118 ° to 122 ° · CMC 0,04° radius of curvature — 100 µm to 300 µm · CMC 0,08 µm CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN ISO 6508-2 | 813-MP-C301 | |
| 329 | Vickers penetrating bodies | Calibration – force, mechanical tests angle of opposite walls — 134 ° to 138 ° · CMC 0,04° CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN ISO 6507-2 | 813-MP-C301 | |
| 330 | Hardness – hardness testers | Calibration – force, mechanical tests Shore A — 1 ShA to 110 ShA · CMC 0,22 ShA Shore B — 1 ShB to 110 ShB · CMC 0,22 ShB Shore C — 1 ShC to 110 ShC · CMC 0,22 ShC Shore D — 1 ShD to 110 ShD · CMC 0,22 ShD Shore DO — 1 ShDO to 110 ShDO · CMC 0,22 ShDO IRHD M — 1 °IRHD M to 110 °IRHD M · CMC 0,42 °IRHD M IRHD N — 1 °IRHD N to 110 °IRHD N · CMC 0,22 °IRHD N IRHD H — 1 °IRHD H to 110 °IRHD H · CMC 0,22 °IRHD H IRHD L — 1 °IRHD L to 110 °IRHD L · CMC 0,22 °IRHD L CMC for the field of measured quantity: Force, mechanical tests |
Combined measurement (force, hardness, penetration of the penetrating body) | 813-MP-C308 (kap. 5.1.) | |
| 331 | AC current ratio / Current measuring transformers | Calibration – electrical quantities 05 A to 5 000 A/ 5 A and 1 A; 50 Hz — 0,1 to 5 000 · CMC 0,002 % CMC for the field of measured quantity: Electrical quantities |
Comparison with a measuring transformer | 817-MP-C701 | |
| 332 | Current phase displacement / Current measuring transformers | Calibration – electrical quantities 0 5 A to 5 000 A/ 5 A and 1 A; 50 Hz — -600 ′ to 600 ′ · CMC 0,07′ CMC for the field of measured quantity: Electrical quantities |
Comparison with a measuring transformer | 817-MP-C701 | |
| 333 | AC voltage ratio / Voltage measuring transformers | Calibration – electrical quantities 5 kV /100 V; 50 Hz — 50 · CMC 0,006 % 10 kV /100 V; 50 Hz — 100 · CMC 0,006 % 22 kV/100 V; 50 Hz — 220 · CMC 0,006 % CMC for the field of measured quantity: Electrical quantities |
Comparison with a measuring transformer | 817-MP-C701 | |
| 334 | AC voltage ratio / Voltage measuring transformers | Calibration – electrical quantities 100 V to 400 kV/5 V to 250 V; 50 Hz — 0,4 to 80 000 · CMC 0,007 % CMC for the field of measured quantity: Electrical quantities |
Comparison with an HV divider | 817-MP-C701 | |
| 335 | Voltage measuring transformers / Voltage phase displacement | Calibration – electrical quantities 5 kV; 10 kV and 22 kV/100 V; 50 Hz — -600 ′ to 600 ′ · CMC 0,21′ CMC for the field of measured quantity: Electrical quantities |
Comparison with a measuring transformer | 817-MP-C701 | |
| 336 | Voltage measuring transformers / Voltage phase displacement | Calibration – electrical quantities 100 V to 400 kV/5 V to 250 V; 50Hz — -600 ′ to 600 ′ · CMC 0,24′ CMC for the field of measured quantity: Electrical quantities |
Comparison with an HV divider | 817-MP-C701 | |
| 337 | Rogowski coils / AC current | Calibration – electrical quantities 1 turn — 0 A to 10 kA · CMC 0,021 % CMC for the field of measured quantity: Electrical quantities |
Comparison with a current measuring transformer | 817-MP-C705 | |
| 338 | Magnetic induction / Reference magnets | Calibration – magnetic quantities 0,3 mT to 2 T · CMC (0,21 až 1) % CMC for the field of measured quantity: Magnetic quantities |
Comparison with a standard teslameter | 817-MP-C607 | |
| 339 | Spectral reflectance factor R / Spectrophotometers | Calibration – optical quantities 8°/t, 8°/d; 380 nm to 460 nm — 0 % to 100 % · CMC (0,1 + 0,010·R) % (abs.) 8°/t, 8°/d; 465 nm to 780 nm — 0 % to 100 % · CMC (0,12 + 0,008·R) % (abs.) 0°/45°; 380 nm to 780 nm — 0 % to 100 % · CMC (0,17 + 0,014·R) % (abs.) CMC for the field of measured quantity: Optical quantities |
Comparison with a colorimetric standard | 818-MP-C802 | |
| 340 | Spectral reflectance factor R / Colorimetric standard | Calibration – optical quantities 8°/t, 8°/d; 380 nm to 460 nm — 0 % to 100 % · CMC (0,1 + 0,010·R) % (abs.) 8°/t, 8°/d; 465 nm to 780 nm — 0 % to 100 % · CMC (0,12 + 0,008·R) % (abs.) 0°/45°; 380 nm to 780 nm — 0 % to 100 % · CMC (0,17 + 0,014·R) % (abs.) CMC for the field of measured quantity: Optical quantities |
Measurement by a reference spectrophotometer | 818-MP-C802 | |
| 341 | Surface colour, colorimetric coordinates / Spectrophotometers, colorimeters | Calibration – optical quantities L*; 8°/t, 8°/d, 0°/45° — 2 to 99 · CMC 0,35 (abs.) a*; 8°/t, 8°/d, 0°/45° — -110 to 110 · CMC 0,25 (abs.) b*; 8°/t, 8°/d, 0°/45° — -110 to 110 · CMC 0,25 (abs.) CMC for the field of measured quantity: Optical quantities |
Comparison with a colorimetric standard | 818-MP-C802 | |
| 342 | Surface colour, colorimetric coordinates / Colorimetric standard | Calibration – optical quantities L*; 8°/t, 8°/d, 0°/45° — 2 to 99 · CMC 0,40 (abs.) a*; 8°/t, 8°/d, 0°/45° — -110 to 110 · CMC 0,30 (abs.) b*; 8°/t, 8°/d, 0°/45° — -110 to 110 · CMC 0,30 (abs.) CMC for the field of measured quantity: Optical quantities |
Measurement by a reference spectrophotometer | 818-MP-C802 | |
| 343 | Surface colour, colorimetric coordinates / Spectrophotometers, colorimeters | Calibration – optical quantities Y; 8°/t, 8°/d, 0°/45 — 0,3 to 100 · CMC 0,25 (abs.) x; 8°/t, 8°/d, 0°/45 — 0,002 to 0,7 · CMC 0,0005 (abs.) y; 8°/t, 8°/d, 0°/45 — 0,002 to 0,8 · CMC 0,0005 (abs.) CMC for the field of measured quantity: Optical quantities |
Comparison with a colorimetric standard | 818-MP-C802 | |
| 344 | Surface colour, colorimetric coordinates / Colorimetric standard | Calibration – optical quantities Y; 8°/t, 8°/d, 0°/45 — 0,3 to 100 · CMC 0,35 (abs.) x; 8°/t, 8°/d, 0°/45 — 0,002 to 0,7 · CMC 0,0007 (abs.) y; 8°/t, 8°/d, 0°/45 — 0,002 to 0,8 · CMC 0,0007 (abs.) CMC for the field of measured quantity: Optical quantities |
Measurement by a reference spectrophotometer | 818-MP-C802 | |
| 345 | Surface colour, colorimetric coordinates / Spectrophotometers, colorimeters | Calibration – optical quantities L; 8°/t, 8°/d, 0°/45 — 2 to 99 · CMC 0,35 (abs.) u´; 8°/t, 8°/d, 0°/45 — 0,002 to 0,6 · CMC 0,0005 (abs.) v´; 8°/t, 8°/d, 0°/45 — 0,002 to 0,6 · CMC 0,0005 (abs.) CMC for the field of measured quantity: Optical quantities |
Comparison with a colorimetric standard | 818-MP-C802 | |
| 346 | Surface colour, colorimetric coordinates / Colorimetric standard | Calibration – optical quantities L; 8°/t, 8°/d, 0°/45 — 2 to 99 · CMC 0,40 (abs.) u´; 8°/t, 8°/d, 0°/45 — 0,002 to 0,6 · CMC 0,0008 (abs.) v´; 8°/t, 8°/d, 0°/45 — 0,002 to 0,6 · CMC 0,0008 (abs.) CMC for the field of measured quantity: Optical quantities |
Measurement by a reference spectrophotometer | 818-MP-C802 | |
| 347 | Gloss / Gloss meters, gloss standards | Calibration – optical quantities 20°, 60°, 85° — 0,1 GU to 150 GU · CMC 1,8 GU CMC for the field of measured quantity: Optical quantities |
ISO 2813 | 818-MP-C808 | |
| 348 | Illuminance / Light sources | Calibration – optical quantities 5 lx to 50 000 lx · CMC 2,2 % CMC for the field of measured quantity: Optical quantities |
Measurement by a reference photometer | 818-MP-C801 | |
| 349 | Illuminance / Luxmeters | Calibration – optical quantities 1 lx to 50 000 lx · CMC 0,8 % CMC for the field of measured quantity: Optical quantities |
Comparison with a reference photometer | 818-MP-C811 | |
| 350 | Irradiance / colorimetric boxes | Calibration – optical quantities 230 nm to 470 nm — 0,1 µW·cm⁻² to 1 000 mW·cm⁻² · CMC 5 % CMC for the field of measured quantity: Optical quantities |
Comparison with a reference photometer | 818-MP-C801 | |
| 351 | Correlated colour temperature / colorimetric (light) boxes | Calibration – optical quantities 2 000 K to 10 000 K · CMC 30 K CMC for the field of measured quantity: Optical quantities |
Measurement by a reference spectrophotometer | 818-MP-C801 | |
| 352 | Regular spectral transmittance / Transmission spectrophotometers, standard filters | Calibration – optical quantities (200 ≤ λ < 380) nm — 0,1 to 1 · CMC 0,0012 (abs,) (200 ≤ λ < 380) nm — 0,001 to 0,1 · CMC 0,0001 (abs,) (380 ≤ λ < 1000) nm — 0,6 to 1 · CMC 0,0008 (abs,) (380 ≤ λ < 400) nm — 0,3 to 0,6 · CMC 0,0041 (abs,) (400 ≤ λ < 700) nm — 0,3 to 0,6 · CMC 0,00056 (abs,) (700 ≤ λ ≤ 1000) nm — 0,3 to 0,6 · CMC 0,0017 (abs,) (380 ≤ λ < 400) nm — 0,02 to 0,3 · CMC 0,0015 (abs,) (400 ≤ λ ≤ 1000) nm — 0,02 to 0,3 · CMC 0,00022 (abs,) (380 ≤ λ < 400) nm — 0,001 to 0,02 · CMC 0,0002 (abs,) (400 ≤ λ ≤ 1000) nm — 0,001 to 0,02 · CMC 0,00008 (abs,) CMC for the field of measured quantity: Optical quantities |
Comparison with a reference photometer | 818-MP-C810 | |
| 353 | Regular spectral absorbance / Transmission spectrophotometers, standard filters | Calibration – optical quantities (200 ≤ λ < 380) nm — 0,00 to 1,00 - · CMC 0,0005 do 0,0052(abs,) (200 ≤ λ < 380) nm — 1,00 to 3,00 · CMC 0,0004 do 0,046(abs,) (380 ≤ λ < 1 +000) nm — 0,00 to 0,22 · CMC 0,0003 do 0,0006(abs,) (380 ≤ λ < 400) nm — 0,22 to 0,52 · CMC 0,0030 do 0,0060(abs,) (400 ≤ λ < 700) nm — 0,22 to 0,52 · CMC 0,0004 do 0,0008(abs,) (700 ≤ λ ≤ 1 000) nm — 0,22 to 0,52 · CMC 0,0012 do 0,0025(abs,) (380 ≤ λ < 400) nm — 0,52 to 1,70 · CMC 0,0022 do 0,034(abs,) (400 ≤ λ ≤ 1 000) nm — 0,52 to 1,70 · CMC 0,0003 do 0,0048(abs,) (380 ≤ λ < 400) nm — 1,70 to 3,00 · CMC 0,0044 do 0,097(abs,) (400 ≤ λ ≤ 1 000) nm — 1,70 to 3,00 · CMC 0,0017 do 0,036(abs,) CMC for the field of measured quantity: Optical quantities |
Comparison with a reference photometer | 818-MP-C810 | |
| 354 | Wavelength λ / Transmission spectrophotometers | Calibration – optical quantities 200 nm to 1 700 nm · CMC 0,2 nm CMC for the field of measured quantity: Optical quantities |
Comparison with a standard filter | 818-MP-C810 | |
| 355 | Wavelength λ / Standard filters | Calibration – optical quantities 200 nm to 1 700 nm · CMC 0,2 nm CMC for the field of measured quantity: Optical quantities |
Measurement by a reference spectrophotometer | 818-MP-C810 | |
| 356 | Transmission optical density D / Optical densitometers | Calibration – optical quantities 0 to 4,5 · CMC 0,0038 (abs.) CMC for the field of measured quantity: Optical quantities |
Comparison with an optical density standard | 818-MP-C812 | |
| 357 | Transmission optical density D / Optical density standards | Calibration – optical quantities 0 to 4,5 · CMC 0,0038 (abs.) CMC for the field of measured quantity: Optical quantities |
Measurement by a reference densitometer | 818-MP-C812 | |
| 358 | Optical power / Optical radiometers, fibre power meters | Calibration – optical quantities 800 nm to 920 nm — 1·10⁻⁹ W to 10 W · CMC 0,40 % 920 nm to 960 nm — 1·10⁻⁹ W to 10 W · CMC 0,50 % 960 nm to 1 000 nm — 1·10⁻⁹ W to 10 W · CMC 0,45 % 1 000 nm to 1 580 nm — 1·10⁻⁹ W to 10 W · CMC 0,47 % 1 580 nm to 1 650 nm — 1·10⁻⁹ W to 10 W · CMC 0,60 % CMC for the field of measured quantity: Optical quantities |
Comparison with a reference detector⁴ | 818-MP-C813 | |
| 359 | Optical attenuation / Attenuators | Calibration – optical quantities 800 nm to 1 650 nm — 0 dB to 65 dB · CMC 0,052dB (abs.) CMC for the field of measured quantity: Optical quantities |
Comparison with a reference attenuator | 818-MP-C813 | |
| 360 | Linearity / Fibre power meters | Calibration – optical quantities Power level 0 dBm to -65 dBm; 800 nm to 1 650 nm — 0 dB to 0,5 dB · CMC 0,004 dB CMC for the field of measured quantity: Optical quantities |
Comparison with a reference detector⁴ | 818-MP-C813 | |
| 361 | Wavelength / Fibre spectral analyzers | Calibration – optical quantities 800 nm to 1 650 nm · CMC 4·10⁻⁹ nm CMC for the field of measured quantity: Optical quantities |
Comparison with a reference radiation source, spectrometer / wavemeter | 818-MP-C813 | |
| 362 | Luminous intensity / Standard light sources | Calibration – optical quantities 1 cd to 20 000 cd · CMC 0,8 % CMC for the field of measured quantity: Optical quantities |
Measurement by a reference photometer | 818-MP-C811 | |
| 363 | Luminance / Luminance meters | Calibration – optical quantities 1 cd m⁻² to 30 000 cd m⁻² · CMC 0,94 % CMC for the field of measured quantity: Optical quantities |
Primary realization of luminance / Comparison with a reference luminance meter | 818-MP-C805 | |
| 364 | Luminous flux / Standard light sources | Calibration – optical quantities 10 lm to 20 000 lm · CMC 1,0 % CMC for the field of measured quantity: Optical quantities |
Comparison with a standard light source in an integrating sphere or on a reference goniophotometer | 818-MP-C807 | |
| 365 | Spectral irradiance / Spectroradiometers | Calibration – optical quantities 300 nm to 400 nm — 0,65 mW m⁻² nm⁻¹ to 300 mW m⁻² nm⁻¹ · CMC 3,4 % 400 nm to 1 700 nm — 0,65 mW m⁻² nm⁻¹ to 300 mW m⁻² nm⁻¹ · CMC 3,0 % 1 700 nm to 2 500 nm — 0,65 mW m⁻² nm⁻¹ to 300 mW m⁻² nm⁻¹ · CMC 4,5 % CMC for the field of measured quantity: Optical quantities |
Comparison with a standard optical radiation source | 818-MP-C806 | |
| 366 | Spectral radiance / Spectroradiometers | Calibration – optical quantities 370 nm to 800 nm — 1,12 mW sr⁻¹m⁻² nm⁻¹ to 10,00 mW sr⁻¹m⁻² nm⁻¹ · CMC 3,2 % 800 nm to 1 000 nm — 1,50 mW sr⁻¹m⁻² nm⁻¹ to 95,00 mW sr⁻¹m⁻² nm⁻¹ · CMC 3,6 % 1 000 nm to 1 700 nm — 1,50 mW sr⁻¹m⁻² nm⁻¹ to 95,00 mW sr⁻¹m⁻² nm⁻¹ · CMC 3,0 % CMC for the field of measured quantity: Optical quantities |
Comparison with a standard source and a spectral reflectance standard. | 818-MP-C806 | |
| 367 | Wavelength λ / spectroradiometer | Calibration – optical quantities 365 nm to 923 nm · CMC 0,4 nm CMC for the field of measured quantity: Optical quantities |
Comparison with a standard source | 818-MP-C806 | |
| 368 | Spectrally integral parameters / Optical radiation sources | Calibration – optical quantities Correlated colour temperature Tc — 2 000 K to 10 000 K · CMC 20 K Colour rendering index Ra — 1 to 100 · CMC 1,2 (abs.) Light colour, colorimetric coordinates; x — 0,002 to 0,7 · CMC 0,0025 (abs.) Light colour, colorimetric coordinates; y — 0,002 to 0,8 · CMC 0,0020 (abs.) Light colour, colorimetric coordinates; u´ — 0,002 to 0,6 · CMC 0,0017 (abs.) Light colour, colorimetric coordinates; v´ — 0,002 to 0,6 · CMC 0,0015 (abs.) CMC for the field of measured quantity: Optical quantities |
Measurement by a reference spectrophotometer | 818-MP-C806 | |
| 369 | Spectrally integral parameters / Spectrophotometers | Calibration – optical quantities Correlated colour temperature Tc — 2 000 K to 10 000 K · CMC 20 K Colour rendering index Ra — 1 to 100 · CMC 0,7 (abs.) Light colour, colorimetric coordinates; x — 0,002 to 0,7 · CMC 0,0014 (abs.) Light colour, colorimetric coordinates; y — 0,002 to 0,8 · CMC 0,0010 (abs.) Light colour, colorimetric coordinates; u´ — 0,002 to 0,6 · CMC 0,0009 (abs.) Light colour, colorimetric coordinates; v´ — 0,002 to 0,6 · CMC 0,0006 (abs.) CMC for the field of measured quantity: Optical quantities |
Comparison with a standard optical radiation source or a reference spectroradiometer | 818-MP-C806 | |
| 370 | Sound pressure level / Acoustic calibrators | Calibration – acoustic quantities and mechanical vibration re 20·10⁻⁶ Pa — 60 dB to 134 dB · CMC 0,09 dB CMC for the field of measured quantity: Acoustic quantities and mechanical vibration |
Comparison with a standard microphone in relation to frequency and total distortion (ČSN EN 60942) | 812-MP-C211 | |
| 371 | Microphone sensitivity / Laboratory standard microphones | Calibration – acoustic quantities and mechanical vibration re 1V·Pa⁻¹ — -40 dB to -24 dB · CMC 0,05 dB CMC for the field of measured quantity: Acoustic quantities and mechanical vibration |
Reciprocity calibration method according to the nominal sensitivity of the standard microphone (ČSN EN 61094-1, ČSN EN 61094-2) | 812-MP-C216 | |
| Regional Inspectorate Kroměříž | |||||
| 372 | Length gauges rolling, contactless | Calibration – length 0,1 m to 10⁵ m · CMC 0,005 % CMC for the field of measured quantity: Length |
Comparison using a tape measure, non-contact length gauges or non-contact length gauge reference standard | 620-MP-C002 | |
| 373 | Index heads and tables, goniometers, instruments for checking angular divisions, angle encoders, torque wrench angle sensors, built-in angle sensors, polygons, angle gauges, optical prisms | Calibration – plane angle from 0 ° to 360 ° · CMC 0,03″ CMC for the field of measured quantity: Plane angle |
Comparison with an optical polygon, autocollimator or rotary table | 411-MP-C006 | |
| 374 | Mass of weights | Calibration – mass from 1 mg to 20 mg · CMC 0,001 0 mg 50 mg · CMC 0,001 3 mg 100 mg · CMC 0,001 6 mg 200 mg · CMC 0,002 0 mg 500 mg · CMC 0,002 6 mg 1 g · CMC 0,003 mg 2 g · CMC 0,004 mg 5 g · CMC 0,005 mg 10 g · CMC 0,006 mg 20 g · CMC 0,008 mg 50 g · CMC 0,010 mg 100 g · CMC 0,016 mg 200 g · CMC 0,030 mg 500 g · CMC 0,080 mg 1 kg · CMC 0,15 mg 2 kg · CMC 0,30 mg 5 kg · CMC 0,80 mg 10 kg · CMC 1,5 mg 20 kg · CMC 3,3 mg 50 kg · CMC 8 mg 100 kg · CMC 50 mg 200 kg · CMC 100 mg 500 kg · CMC 250 mg 1 000 kg · CMC 500 mg CMC for the field of measured quantity: Mass |
Comparison with a reference weight | 612-MP-C131 | |
| 375 | Balances with non-automatic and automatic function | Calibration – mass Weight E2 — 0 g to 20 kg · CMC 5·10⁻⁷ Weight F1 — 20 kg to 50 kg · CMC 1,6·10⁻⁶ Weight F2 — 50 kg to 600 kg · CMC 5·10⁻⁶ Weight M — 600 kg to 200 000 kg · CMC 1,6·10⁻⁵ CMC for the field of measured quantity: Mass |
Loading using a reference weight | 612-MP-C132 | |
| 376 | Force / force-proving instruments | Calibration – force, mechanical tests 0,02 N to 5 N · CMC 0,002 5 N to 2 MN · CMC 0,001 CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a force transmission standard (force-proving instrument) or by suspending weights | 811-MP-C111 | |
| 377 | Torque / torque measuring instruments | Calibration – force, mechanical tests 0,02 N·m to 0,2 N·m · CMC 0,001 0,2 N·m to 1 N·m · CMC 0,000 09 1 N·m to 100 N·m · CMC 0,000 08 100 N·m to 1 kN·m · CMC 0,000 1 1 kN·m to 10 kN·m · CMC 0,000 4 CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a standard torque measuring instrument, torque transmission standard (torque sensor) or using weights and torque arms | 811-MP-C102 | |
| 378 | Torque / torque wrenches | Calibration – force, mechanical tests 0,02 N·m to 3 kN·m · CMC 0,005 CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a torque transmission standard (torque sensor) (ČSN EN ISO 6789-1, ČSN EN ISO 6789-2) | 811-MP-C103 | |
| 379 | Torque / equipment for the calibration of torque wrenches | Calibration – force, mechanical tests 0,02 N·m to 500 N·m · CMC 0,001 500 N·m to 10 kN·m · CMC 0,000 4 CMC for the field of measured quantity: Force, mechanical tests |
Calibration by reference torque wrench, torque transmission standard (torque sensor) or by means of weights and torque arms | 811-MP-C104 | |
| 380 | Torque / tightening tools and systems | Calibration – force, mechanical tests 0,25 N·m to 10 kN·m · CMC 0,005 CMC for the field of measured quantity: Force, mechanical tests |
Calibration by a calibration device for torque wrenches, torque screwdrivers and tighteners | 411-MP-C103 | |
| Regional Inspectorate České Budějovice | |||||
| 381 | Mass of weights | Calibration – mass from 1 mg to 20 mg · CMC 0,001 0 mg 50 mg · CMC 0,001 3 mg 100 mg · CMC 0,001 6 mg 200 mg · CMC 0,002 0 mg 500 mg · CMC 0,002 6 mg 1 g · CMC 0,003 mg 2 g · CMC 0,004 mg 5 g · CMC 0,005 mg 10 g · CMC 0,006 mg 20 g · CMC 0,008 mg 50 g · CMC 0,010 mg 100 g · CMC 0,016 mg 200 g · CMC 0,030 mg 500 g · CMC 0,080 mg 1 kg · CMC 0,15 mg 2 kg · CMC 0,30 mg 5 kg · CMC 0,80 mg 10 kg · CMC 1,5 mg 20 kg · CMC 3,3 mg 50 kg · CMC 8 mg 100 kg · CMC 50 mg 200 kg · CMC 100 mg 500 kg · CMC 250 mg 1 000 kg · CMC 500 mg CMC for the field of measured quantity: Mass |
Comparison with a reference weight | 612-MP-C131 | |
| 382 | Balances with non-automatic and automatic function | Calibration – mass Weight E2 — 0 g to 20 kg · CMC 5·10⁻⁷ Weight F1 — 20 kg to 50 kg · CMC 1,6·10⁻⁶ Weight F2 — 50 kg to 600 kg · CMC 5·10⁻⁶ Weight M — 600 kg to 200 000 kg · CMC 1,6·10⁻⁵ CMC for the field of measured quantity: Mass |
Loading using a reference weight | 612-MP-C132 | |
| 383 | Time interval / mechanically operated stopwatches | Calibration – time and frequency quantities 0,1 s to 35 999,99 s · CMC 16 ms CMC for the field of measured quantity: Time and frequency quantities |
Direct comparison with a standard | 113-MP-C013 | |
| 384 | Relative frequency error of the time base / stopwatches with LCD | Calibration – time and frequency quantities -1·10⁻³ to 1·10⁻³ · CMC 3·10⁻⁷ CMC for the field of measured quantity: Time and frequency quantities |
Frequency measurement - capacitive coupling to the LCD | 113-MP-C013 | |
| Regional Inspectorate Plzeň | |||||
| 385 | Mass of weights | Calibration – mass from 1 mg to 20 mg · CMC 0,001 0 mg 50 mg · CMC 0,001 3 mg 100 mg · CMC 0,001 6 mg 200 mg · CMC 0,002 0 mg 500 mg · CMC 0,002 6 mg 1 g · CMC 0,003 mg 2 g · CMC 0,004 mg 5 g · CMC 0,005 mg 10 g · CMC 0,006 mg 20 g · CMC 0,008 mg 50 g · CMC 0,010 mg 100 g · CMC 0,016 mg 200 g · CMC 0,030 mg 500 g · CMC 0,080 mg 1 kg · CMC 0,15 mg 2 kg · CMC 0,30 mg 5 kg · CMC 0,80 mg 10 kg · CMC 1,5 mg 20 kg · CMC 3,3 mg 50 kg · CMC 8 mg 100 kg · CMC 50 mg 200 kg · CMC 100 mg 500 kg · CMC 250 mg 1 000 kg · CMC 500 mg CMC for the field of measured quantity: Mass |
Comparison with a reference weight | 612-MP-C131 | |
| 386 | Balances with non-automatic and automatic function | Calibration – mass Weight E2 — 0 g to 20 kg · CMC 5·10⁻⁷ Weight F1 — 20 kg to 50 kg · CMC 1,6·10⁻⁶ Weight F2 — 50 kg to 600 kg · CMC 5·10⁻⁶ Weight M — 600 kg to 200 000 kg · CMC 1,6·10⁻⁵ CMC for the field of measured quantity: Mass |
Loading using a reference weight | 612-MP-C132 | |
| Regional Inspectorate Most | |||||
| 387 | Mass of weights | Calibration – mass from 1 mg to 20 mg · CMC 0,001 0 mg 50 mg · CMC 0,001 3 mg 100 mg · CMC 0,001 6 mg 200 mg · CMC 0,002 0 mg 500 mg · CMC 0,002 6 mg 1 g · CMC 0,003 mg 2 g · CMC 0,004 mg 5 g · CMC 0,005 mg 10 g · CMC 0,006 mg 20 g · CMC 0,008 mg 50 g · CMC 0,010 mg 100 g · CMC 0,016 mg 200 g · CMC 0,030 mg 500 g · CMC 0,080 mg 1 kg · CMC 0,15 mg 2 kg · CMC 0,30 mg 5 kg · CMC 0,80 mg 10 kg · CMC 1,5 mg 20 kg · CMC 3,3 mg 50 kg · CMC 8 mg 100 kg · CMC 50 mg 200 kg · CMC 100 mg 500 kg · CMC 250 mg 1 000 kg · CMC 500 mg CMC for the field of measured quantity: Mass |
Comparison with a reference weight | 612-MP-C131 | |
| 388 | Balances with non-automatic and automatic function | Calibration – mass Weight E2 — 0 g to 20 kg · CMC 5·10⁻⁷ Weight F1 — 20 kg to 50 kg · CMC 1,6·10⁻⁶ Weight F2 — 50 kg to 600 kg · CMC 5·10⁻⁶ Weight M — 600 kg to 200 000 kg · CMC 1,6·10⁻⁵ CMC for the field of measured quantity: Mass |
Loading using a reference weight | 612-MP-C132 | |
| Regional Inspectorate Jihlava | |||||
| 389 | Mass of weights | Calibration – mass from 1 mg to 20 mg · CMC 0,001 0 mg 50 mg · CMC 0,001 3 mg 100 mg · CMC 0,001 6 mg 200 mg · CMC 0,002 0 mg 500 mg · CMC 0,002 6 mg 1 g · CMC 0,003 mg 2 g · CMC 0,004 mg 5 g · CMC 0,005 mg 10 g · CMC 0,006 mg 20 g · CMC 0,008 mg 50 g · CMC 0,010 mg 100 g · CMC 0,016 mg 200 g · CMC 0,030 mg 500 g · CMC 0,080 mg 1 kg · CMC 0,15 mg 2 kg · CMC 0,30 mg 5 kg · CMC 0,80 mg 10 kg · CMC 1,5 mg 20 kg · CMC 3,3 mg 50 kg · CMC 8 mg 100 kg · CMC 50 mg 200 kg · CMC 100 mg 500 kg · CMC 250 mg 1 000 kg · CMC 500 mg CMC for the field of measured quantity: Mass |
Comparison with a reference weight | 612-MP-C131 | |
| 390 | Balances with non-automatic and automatic function | Calibration – mass Weight E2 — 0 g to 20 kg · CMC 5·10⁻⁷ Weight F1 — 20 kg to 50 kg · CMC 1,6·10⁻⁶ Weight F2 — 50 kg to 600 kg · CMC 5·10⁻⁶ Weight M — 600 kg to 200 000 kg · CMC 1,6·10⁻⁵ CMC for the field of measured quantity: Mass |
Loading using a reference weight | 612-MP-C132 | |
| Regional Inspectorate Olomouc | |||||
| 391 | Mass of weights | Calibration – mass from 1 mg to 20 mg · CMC 0,001 0 mg 50 mg · CMC 0,001 3 mg 100 mg · CMC 0,001 6 mg 200 mg · CMC 0,002 0 mg 500 mg · CMC 0,002 6 mg 1 g · CMC 0,003 mg 2 g · CMC 0,004 mg 5 g · CMC 0,005 mg 10 g · CMC 0,006 mg 20 g · CMC 0,008 mg 50 g · CMC 0,010 mg 100 g · CMC 0,016 mg 200 g · CMC 0,030 mg 500 g · CMC 0,080 mg 1 kg · CMC 0,15 mg 2 kg · CMC 0,30 mg 5 kg · CMC 0,80 mg 10 kg · CMC 1,5 mg 20 kg · CMC 3,3 mg 50 kg · CMC 8 mg 100 kg · CMC 50 mg 200 kg · CMC 100 mg 500 kg · CMC 250 mg 1 000 kg · CMC 500 mg CMC for the field of measured quantity: Mass |
Comparison with a reference weight | 612-MP-C131 | |
| 392 | Balances with non-automatic and automatic function | Calibration – mass Weight E2 — 0 g to 20 kg · CMC 5·10⁻⁷ Weight F1 — 20 kg to 50 kg · CMC 1,6·10⁻⁶ Weight F2 — 50 kg to 600 kg · CMC 5·10⁻⁶ Weight M — 600 kg to 200 000 kg · CMC 1,6·10⁻⁵ CMC for the field of measured quantity: Mass |
Loading using a reference weight | 612-MP-C132 | |
| 393 | Hardness – hardness testers | Calibration – force, mechanical tests Rockwell A — 10 HRA to 100 HRA · CMC 0,38 HR Rockwell B — 10 HRBW to 110 HRBW · CMC 0,38 HR Rockwell C — 10 HRC to 80 HRC · CMC 0,38 HR Rockwell D — 10 HRD to 90 HRD · CMC 0,38 HR Rockwell E — 10 HREW to 110 HREW · CMC 0,38 HR Rockwell F — 10 HRFW to 100 HRFW · CMC 0,38 HR Rockwell G — 10 HRGW to 100 HRGW · CMC 0,38 HR Rockwell H — 10 HRHW to 110 HRHW · CMC 0,38 HR Rockwell K — 6 HRKW to 110 HRKW · CMC 0,38 HR Rockwell 15N — 10 HR15N to 100 HR15N · CMC 0,57 HR Rockwell 30N — 10 HR30N to 100 HR30N · CMC 0,57 HR Rockwell 45N — 10 HR45N to 90 HR45N · CMC 0,57 HR Rockwell 15T — 10 HR15TW to 100 HR15TW · CMC 0,57 HR Rockwell 30T — 10 HR30TW to 90 HR30TW · CMC 0,57 HR Rockwell 45T — 6 HR45TW to 80 HR45TW · CMC 0,57 HR CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN ISO 6508-2, ASTM E18 | 813-MP-C307 | |
| 394 | Hardness – hardness testers | Calibration – force, mechanical tests Vickers — 20 HV to 225 HV · CMC 0,32 % Vickers — 225 HV to 700 HV · CMC 0,32 % Vickers — 700 HV to 3 000 HV · CMC 0,32 % CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN ISO 6507-2, ASTM E384 | 813-MP-C307 | |
| 395 | Hardness – hardness testers | Calibration – force, mechanical tests Brinell — 20 HBW to 200 HBW · CMC 0,30 % Brinell — 200 HBW to 500 HBW · CMC 0,30 % Brinell — 500 HBW to 650 HBW · CMC 0,30 % CMC for the field of measured quantity: Force, mechanical tests |
ČSN EN ISO 6506-2, ASTM E10 | 813-MP-C307 | |
| Calibration items | |||||
| 396 | Velocity of transport vehicles and objects | Calibration – mechanical motion 1 km·h⁻¹ to 999 km·h⁻¹ · CMC 0,2 km·h⁻¹ CMC for the field of measured quantity: Mechanical motion |
Comparison with a standard speedometer | 812-MP-C209 | |
| 397 | Velocity of transport vehicles and objects | Calibration – mechanical motion 0,1 km·h⁻¹ to 320 km·h⁻¹ · CMC 0,01 % CMC for the field of measured quantity: Mechanical motion |
Measurement using an optoelectronic delay line | 812-MP-C209 | |
| TESTCOM Praha | |||||
| 398 | Antenna factor / antennas | Calibration – electrical quantities Distance 3 m; 30 MHz to 100 MHz — -10 dB/m to +60 dB/m · CMC 2,8 dB Distance 3 m; 100 MHz to 300 MHz — -10 dB/m to +60 dB/m · CMC 2,8 dB Distance 3 m; 300 MHz to 1 GHz — -10 dB/m to +60 dB/m · CMC 3,0 dB Distance 3 m; 1 GHz to 18 000 MHz — -10 dB/m to +60 dB/m · CMC 2,0 dB Distance 10 m; 30 MHz to 100 MHz — -10 dB/m to +60 dB/m · CMC 2,2 dB Distance 10 m; 100 MHz to 300 MHz — -10 dB/m to +60 dB/m · CMC 1,5 dB Distance 10 m; 300 MHz to 1 GHz — -10 dB/m to +60 dB/m · CMC 1,4 dB Distance 10 m; 1 GHz to 18 GHz — -10 dB/m to +60 dB/m · CMC 2,0 dB CMC for the field of measured quantity: Electrical quantities |
Three-antenna method | 851-MP-C004, kap. 5.1 (ANSI C63.5 kap. 5) | |
| 399 | Antenna factor / antennas | Calibration – electrical quantities Distance 3 m; 30 MHz to 100 MHz — -10 dB/m to +60 dB/m · CMC 3,3 dB Distance 3 m; 100 MHz to 300 MHz — -10 dB/m to +60 dB/m · CMC 3,3 dB Distance 3 m; 300 MHz to 1 GHz — -10 dB/m to +60 dB/m · CMC 3,5 dB Distance 3 m; 1 GHz to 18 GHz — -10 dB/m to +60 dB/m · CMC 2,2 dB Distance 10 m; 30 MHz to 100 MHz — -10 dB/m to +60 dB/m · CMC 2,5 dB Distance 10 m; 100 MHz to 300 MHz — -10 dB/m to +60 dB/m · CMC 1,7 dB Distance 10 m; 300 MHz to 1 GHz — -10 dB/m to +60 dB/m · CMC 1,7 dB Distance 10 m; 1 GHz to 18 GHz — -10 dB/m to +60 dB/m · CMC 2,2 dB CMC for the field of measured quantity: Electrical quantities |
Substitution method | 851-MP-C004, kap. 5.2 (ANSI C63.5 kap. 6) | |
| 400 | Antenna factor / antennas | Calibration – electrical quantities Distance 1 m; 30 MHz to 1 GHz — -10 dB/m to +60 dB/m · CMC 3,5 dB Distance 1 m; 1 GHz to 18 GHz — -10 dB/m to +60 dB/m · CMC 3,1 dB CMC for the field of measured quantity: Electrical quantities |
Measurement of transmission between two identical antennas | 851-MP-C004, kap. 5.4 (SAE ARP 958, Rev.D, kap 3 a 4) | |
| 401 | Antenna factor / loop antennas | Calibration – electrical quantities Distance 1 m; 10 kHz to 30 MHz — -10 dBS/m to +60 dBS/m · CMC 2,2 dB CMC for the field of measured quantity: Electrical quantities |
Measurement of the magnetic field strength of a standard antenna | 851-MP-C004, kap. 5.5 (SAE ARP 958, Rev.D, kap 6 a 7) | |
| 402 | Antenna factor / rod antennas | Calibration – electrical quantities 9 kHz to 30 MHz — -10 dB/m to +60 dB/m · CMC 2,1 dB CMC for the field of measured quantity: Electrical quantities |
Measurement of the matching circuit | 851-MP-C004, kap. 5.3 (ČSN EN 55016-1-4) | |
Reference standards (134)
112-MP-C002
112-MP-C003
112-MP-C004
112-MP-C005
112-MP-C006
113-MP-C007
113-MP-C008
113-MP-C013
113-MP-C014
113-MP-C017
114-MP-C004
131-MP-C003
131-MP-C005
131-MP-C006
133-MP-C001
133-MP-C002
133-MP-C003
133-MP-C004
133-MP-C005
133-MP-C006
133-MP-C007
151 MP-C001
151-MP-C001
151-MP-C002
151-MP-C003
151-MP-C004
151-MP-C005
151-MP-C006
411-MP-C003
411-MP-C004
411-MP-C006
411-MP-C010
411-MP-C011
411-MP-C103
511-MP-C001
511-MP-C003
511-MP-C009
512-MP-C003
512-MP-C103
512-MP-C104
512-MP-C105
551-MP-C401
601-MP-C046
601-MP-C047
601-MP-C049
611-MP-C005
611-MP-C030
611-MP-C034
611-MP-C040
611-MP-C041
611-MP-C042
611-MP-C043
611-MP-C045
611-MP-C060
611-MP-C061
611-MP-C097
611-MP-C098
611-MP-C099
611-MP-C129
611-MP-C130
612-MP-C131
612-MP-C132
614-MP-C002
614-MP-C005
614-MP-C006
614-MP-C008
614-MP-C009
614-MP-C029
614-MP-C033
614-MP-C102
614-MP-C103
614-MP-C104
614-MP-C105
614-MP-C106
614-MP-C146
615-MP-C142
615-MP-C143
615-MP-C147
615-MP-C148
615-MP-C149
615-MP-C151
615-MP-C158
616-MP-C001
616-MP-C002
616-MP-C003
616-MP-C004
616-MP-C005
616-MP-C016
616-MP-C017
620-MP-C002
636-MP-C119
636-MP-C120
811-MP-C101
811-MP-C102
811-MP-C103
811-MP-C104
811-MP-C111
812-MP-C201
812-MP-C207
812-MP-C208
812-MP-C209
812-MP-C210
812-MP-C211
812-MP-C212
812-MP-C216
813-MP-C301
813-MP-C306
813-MP-C307
813-MP-C308
815-MP-C501
815-MP-C503
815-MP-C510
817-MP-C607
817-MP-C701
817-MP-C705
818-MP-C801
818-MP-C802
818-MP-C805
818-MP-C806
818-MP-C807
818-MP-C808
818-MP-C810
818-MP-C811
818-MP-C812
818-MP-C813
851-MP-C004
ANSI C63.5
EURAMET cg-19
ISO 21501-4
SAE ARP 958
ČSN EN 55016-1-4
ČSN EN ISO 3650
ČSN EN ISO 4787
ČSN EN ISO 8655-6