🇨🇿 Budimex S.A., odštěpný závod Česko PL

ČIA 1814 • Hrušová, Czech Republic • 20 methods

Construction

Budimex S.A., odštěpný závod Česko is a laboratory accredited by ČIA under number 1814 (Hrušová, Czech Republic). Its accreditation scope covers 20 test methods in the following areas: Construction. Test objects include: Asphalt mixture, Fresh concrete, Aggregates, Hardened concrete. Most frequently used techniques: Gravimetry, Pressure method.

At a glance

  • Accreditation number: ČIA 1814
  • Methods in scope: 20
  • Types of test objects: 7
  • Techniques used: 2
  • City: Hrušová, Czech Republic
  • Valid until: 28-01-2029
Accreditation number
1814
Accreditation body
ČIA
Address
e.č. 4, 565 55 Hrušová
City
Hrušová, Czech Republic
Division
Laboratorium badawcze
Valid until
28-01-2029

What this laboratory tests (7)

Analytical techniques used (2)

Certificate information

Certificate date
28.01.2026

Accreditation scope — test methods (20)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Soils Determination of mass per unit volume
Regulated area: Tests
ČSN 72 1010, metoda D-1
2 Soils, unbound and hydraulically bound mixtures Determination of reference density and water content by Proctor test
Regulated area: Tests
ČSN EN 13286-2, mimo čl. 7.3, 7.6 a mimo metodu D
3 Soils Determination of moisture content
Regulated area: Tests
Gravimetry ČSN EN ISO 17892-1
4 Aggregates Determination of particle size distribution by sieve analysis
Regulated area: Tests
ČSN EN 933-1
5 Aggregates Determination of moisture content
Regulated area: Tests
Gravimetry ČSN EN 1097-5
6 Soils and base courses Impact loading test by light dynamic plate
Regulated area: Tests
ČSN 73 6192, metoda C
7 Soils and base courses Static plate load test
Regulated area: Tests
ČSN 72 1006, příloha A, B, D
8 Hardened concrete Determination of mass per unit volume
Regulated area: Tests
ČSN EN 12390-7
9 Hardened concrete Determination of compressive strength
Regulated area: Tests
ČSN EN 12390-3
10 Fresh concrete Determination of mass per unit volume
Regulated area: Tests
ČSN EN 12350-6
11 Fresh concrete Slump test
Regulated area: Tests
ČSN EN 12350-2
12 Fresh concrete Determination of air content
Regulated area: Tests
Pressure method ČSN EN 12350-7, mimo čl. 5
13 Asphalt mixture Determination of soluble binder content
Regulated area: Tests
ČSN EN 12697-1
14 Asphalt mixture Determination of grain size
Regulated area: Tests
ČSN EN 12697-2
15 Asphalt mixture Determination of the maximum density
Regulated area: Tests
ČSN EN 12697-5
16 Asphalt mixture Determination of density of test specimen
Regulated area: Tests
ČSN EN 12697-6, mimo metodu C
17 Asphalt mixture Determination of voids
Regulated area: Tests
ČSN EN 12697-8
18 Fresh concrete Fresh concrete sampling
Regulated area: Sampling
ČSN EN 12350-1
19 Asphalt mixture Asphalt mixture sampling
Regulated area: Sampling
ČSN EN 12697-27, mimo čl. 4.2, 4.5, 4.8, 4.9
20 Aggregates Aggregate sampling
Regulated area: Sampling
ČSN EN 932-1, mimo čl. 8.2, 8.3, 8.4

Reference standards (20)

ČSN 72 1006, příloha A, B, D
ČSN 72 1010, metoda D-1
ČSN 73 6192, metoda C
ČSN EN 1097-5
ČSN EN 12350-1
ČSN EN 12350-2
ČSN EN 12350-6
ČSN EN 12350-7, mimo čl. 5
ČSN EN 12390-3
ČSN EN 12390-7
ČSN EN 12697-1
ČSN EN 12697-2
ČSN EN 12697-27, mimo čl. 4.2, 4.5, 4.8, 4.9
ČSN EN 12697-5
ČSN EN 12697-6, mimo metodu C
ČSN EN 12697-8
ČSN EN 13286-2, mimo čl. 7.3, 7.6 a mimo metodu D
ČSN EN 932-1, mimo čl. 8.2, 8.3, 8.4
ČSN EN 933-1
ČSN EN ISO 17892-1

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1814