🇨🇿 ekoDEM Pardubice s.r.o. PL

ČIA 1794 • Dolní Ředice, Czech Republic • 26 methods

Environment

ekoDEM Pardubice s.r.o. is a laboratory accredited by ČIA under number 1794 (Dolní Ředice, Czech Republic). Its accreditation scope covers 26 test methods in the following areas: Environment. Test objects include: Emissions, Workplace air, Emission automated measuring systems.

At a glance

  • Accreditation number: ČIA 1794
  • Methods in scope: 26
  • Types of test objects: 3
  • City: Dolní Ředice, Czech Republic
  • Valid until: 03-09-2031
Accreditation number
1794
Accreditation body
ČIA
Address
K Třešňovce 247, 533 75 Dolní Ředice
City
Dolní Ředice, Czech Republic
Division
Laboratorium Pomiarów w Dziedzinie Ochrony Powietrza
Valid until
03-09-2031

What this laboratory tests (3)

Certificate information

Certificate date
03.09.2026

Accreditation scope — test methods (26)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Emissions Determination of velocity and volumetric flow rate
Regulated area: 1 Emissions
SOP-E-101 (ČSN ISO 10780; ČSN EN 15259; ČSN EN ISO 16911-1)
2 Emissions Determination of gas moisture (condensation method, adsorption method, capacitive sensor)
Regulated area: 1 Emissions
SOP-E-102 (ČSN EN 14790)
3 Emissions Determination of volume concentration of oxygen (O2) by automated analysers (paramagnetic method)
Regulated area: 1 Emissions
SOP-E-103, část A (ČSN EN 14789)
4 Emissions Determination of volume concentration of oxygen (O2) by automated analysers (electrochemical cell method)
Regulated area: 1 Emissions
SOP-E-103, část B (ISO 12039:2019)
5 Emissions Determination of mass concentration of gaseous pollutants (CO, NO, NO2, N2O, NOx, SO2, CH4) and determination of volume concentration of CO2 by automated analysers (NDIR)
carbon monoxide (CO) nitric oxide (NO) nitrogen dioxide (NO2) nitrous oxide (N2O) nitrogen oxides (NOx) sulphur dioxide (SO2) methane (CH4) carbon dioxide (CO2)
Regulated area: 1 Emissions
SOP-E-104, část A (ČSN EN 15058; ČSN ISO 7935; ČSN ISO 10849; ČSN P CEN/TS 17405; ČSN EN ISO 21258; Manuál přístroje MRU MGAPrime)
6 Emissions Determination of mass concentration of gaseous pollutants (NOx) by automated analysers (chemiluminescence)
Regulated area: 1 Emissions
SOP-E-104, část B (ČSN EN 14792)
7 Emissions Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) and mass concentration of methane (CH4) by automated analysers (FID)
Regulated area: 1 Emissions
SOP-E-105 (ČSN EN 12619; ČSN EN ISO 25140)
8 Emissions Determination of mass concentration of volatile organic compounds, carbonyl compounds and amines (VOC) by calculation from measured values
Regulated area: 1 Emissions
SOP-E-106 (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1; EPA Method TO-11A; ČSN P CEN/TS 17638)
9 Emissions Determination of mass concentration of particulate matter (gravimetry)
Regulated area: 1 Emissions
SOP-E-107 (ČSN EN 13284-1; ČSN EN 15259)
10 Emissions Determination of mass concentration of metals by calculation from measured values
Antimony (Sb) Arsenic (As) Tin (Sn) Chromium (Cr) Cobalt (Co) Cadmium (Cd) Copper (Cu) Manganese (Mn) Nickel (Ni) Lead (Pb) Thallium (Tl) Vanadium (V) Zinc (Zn) Aluminium (Al) Silver (Ag) Iron (Fe) Barium (Ba) Mercury (Hg) Beryllium (Be) Tellurium (Te) Selenium (Se) hexavalent chromium (Cr6+)
Regulated area: 1 Emissions
SOP-E-108 (ČSN EN 14385; ČSN EN 13211; EPA Method 29; ČSN EN 13284-1; ČSN EN 15259; EPA Method 0061)
11 Emissions Determination of mass concentration of gases and vapours by calculation from measured values
hydrogen chloride (HCl) hydrogen fluoride (HF) ammonia (NH3) hydrogen sulphide (H2S) sulphur dioxide (SO2) inorganic acids
Regulated area: 1 Emissions
SOP-E-109 (ČSN EN 1911; ČSN P CEN/TS 17340; ČSN 83 4712-1; ČSN EN ISO 21877; ČSN EN 14791)
12 Emissions Determination of mass concentration of persistent organic pollutants POPs (PCDD, PCDF, PCB, PAH) by calculation from measured values
PCDD (polychlorinated dibenzodioxins) PCDF (polychlorinated dibenzofurans) PCB (polychlorinated biphenyls) PAH (polyaromatic hydrocarbons)
Regulated area: 1 Emissions
SOP-E-111 (ČSN EN 1948-3; ČSN EN 1948-4+A1; ISO 11338-1:2003; ČSN ISO 13284-1; ČSN EN 15259)
13 Emissions Determination of mass concentration of gaseous pollutants (CO, NO, NO2, N2O, NOx, SO2, CH4) and determination of volume concentration of CO2 by automated analysers (FTIR)
carbon monoxide (CO) nitric oxide (NO) nitrogen dioxide (NO2) nitrous oxide (N2O) nitrogen oxides (NOx) sulphur dioxide (SO2) methane (CH4) carbon dioxide (CO2)
Regulated area: 1 Emissions
SOP-E-112 (CEN/TS 17337; ČSN P CEN/TS 17337; Manuál přístroje GASMET DX4000 FTIR)
14 Emission automated measuring systems Quality assurance of automated measuring systems
Regulated area: 1 Emissions
SOP-E-113 (ČSN EN 14181, čl. 6.3 – 6.8 QAL2, čl. 8 AST; ČSN EN 13284-2)
15 Emissions Determination of mass concentration of aerosol particle fractions PM10 and PM2.5 (gravimetry)
PM10 fraction PM2.5 fraction
Regulated area: 1 Emissions
SOP-E-114 (ČSN EN 12341; ČSN EN ISO 23210)
16 Workplace air Determination of mass concentration of dust and aerosol (gravimetry)
Regulated area: 2 Workplace air
SOP-P-201 (NV č. 361/2007 Sb.)
17 Workplace air Determination of mass concentration of gases and vapours by calculation from measured values
Regulated area: 2 Workplace air
SOP-P-202 (NV č. 361/2007 Sb.; ČSN EN ISO 16017-1; ČSN EN 689+AC)
18 Workplace air Determination of number concentration of mineral and asbestos fibres by calculation from measured values
Regulated area: 2 Workplace air
SOP-P-202 (NV č. 361/2007 Sb.; ČSN EN 689+AC)
19 Emissions Sampling of particulate matter (isokinetic sampling with manual and automatic control)
Regulated area: Sampling
SOP-EVZ-01 (ČSN EN 13284-1; ČSN EN 15259)
20 Emissions Sampling for determination of metals (Sb, As, Sn, Cr, Co, Cd, Cu, Mn, Ni, Pb, Tl, V, Zn, Al, Ag, Fe, Ba, Hg, Be, Te, Se, Cr6+) (isokinetic sampling with manual and automatic control)
Antimony (Sb) Arsenic (As) Tin (Sn) Chromium (Cr) Cobalt (Co) Cadmium (Cd) Copper (Cu) Manganese (Mn) Nickel (Ni) Lead (Pb) Thallium (Tl) Vanadium (V) Zinc (Zn) Aluminium (Al) Silver (Ag) Iron (Fe) Barium (Ba) Mercury (Hg) Beryllium (Be) Tellurium (Te) Selenium (Se) hexavalent chromium (Cr6+)
Regulated area: Sampling
SOP-EVZ-02 (ČSN EN 14385; ČSN EN 13211; EPA Method 29; ČSN EN 13284-1; ČSN EN 15259; EPA Method 0061)
21 Emissions Sampling for determination of volatile organic compounds (VOC), carbonyl compounds and amines by collection on a solid sorbent
Regulated area: Sampling
SOP-EVZ-03 (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1; EPA Method TO-11A)
22 Emissions Sampling of gases and vapours for determination of HCl, HF, NH3, H2S, SO2, inorganic acids and formaldehyde by absorption into liquid
hydrogen chloride (HCl) hydrogen fluoride (HF) ammonia (NH3) hydrogen sulphide (H2S) sulphur dioxide (SO2) inorganic acids formaldehyde
Regulated area: Sampling
SOP-EVZ-04 (ČSN EN 1911; ČSN P CEN/TS 17340; ČSN 83 4712-2; ČSN EN ISO 21877; ČSN EN 14791; ČSN P CEN/TS 17638)
23 Workplace air Sampling on a solid sorbent (filter, PUF, sorption tube)
Regulated area: Sampling
SOP-PVZ-05 (NV č. 361/2007 Sb.; ČSN EN ISO 16017-1; ČSN EN 689+AC)
24 Workplace air Sampling for determination of HCl, HF, NH3, H2S, inorganic acids into liquid (sorption solution)
hydrogen chloride (HCl) hydrogen fluoride (HF) ammonia (NH3) hydrogen sulphide (H2S) inorganic acids
Regulated area: Sampling
SOP-PVZ-06 (NV č. 361/2007 Sb.)
25 Emissions Sampling for determination of persistent organic pollutants POPs (PCDD, PCDF, PCB and PAH) by the filter/condenser method (isokinetic sampling with manual and automatic control)
PCDD (polychlorinated dibenzodioxins) PCDF (polychlorinated dibenzofurans) PCB (polychlorinated biphenyls) PAH (polyaromatic hydrocarbons)
Regulated area: Sampling
SOP-EVZ-07 (ČSN EN 1948-1; ČSN EN 1948-4+A1; ISO 11338-1:2003; ČSN ISO 13284-1; ČSN EN 15259)
26 Emissions Sampling for determination of mass concentration of aerosol particle fractions PM10 and PM2.5
Regulated area: Sampling
SOP-EVZ-07 (ČSN EN 12341; ČSN EN ISO 23210)

Reference standards (66)

CEN/TS 17337
EPA Method 0061
EPA Method 29
EPA Method TO-11A
ISO 11338-1:2003
ISO 12039:2019
Manuál přístroje GASMET DX4000 FTIR
Manuál přístroje MRU MGAPrime
NV č. 361/2007 Sb.
SOP-E-101
SOP-E-102
SOP-E-103
SOP-E-104
SOP-E-105
SOP-E-106
SOP-E-107
SOP-E-108
SOP-E-109
SOP-E-111
SOP-E-112
SOP-E-113
SOP-E-114
SOP-EVZ-01
SOP-EVZ-02
SOP-EVZ-03
SOP-EVZ-04
SOP-EVZ-07
SOP-P-201
SOP-P-202
SOP-PVZ-05
SOP-PVZ-06
ČSN 83 4712-1
ČSN 83 4712-2
ČSN EN 12341
ČSN EN 12619
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 13284-2
ČSN EN 14181, čl. 6.3 – 6.8 QAL2, čl. 8 AST
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 14791
ČSN EN 14792
ČSN EN 15058
ČSN EN 15259
ČSN EN 1911
ČSN EN 1948-1
ČSN EN 1948-3
ČSN EN 1948-4+A1
ČSN EN 689+AC
ČSN EN ISO 16017-1
ČSN EN ISO 16911-1
ČSN EN ISO 21258
ČSN EN ISO 21877
ČSN EN ISO 23210
ČSN EN ISO 25140
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 13284-1
ČSN ISO 7935
ČSN P CEN/TS 13649
ČSN P CEN/TS 17337
ČSN P CEN/TS 17340
ČSN P CEN/TS 17405
ČSN P CEN/TS 17638

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1794