🇨🇿 ekoDEM Pardubice s.r.o. PL
Environment
ekoDEM Pardubice s.r.o. is a laboratory accredited by ČIA under number 1794 (Dolní Ředice, Czech Republic). Its accreditation scope covers 26 test methods in the following areas: Environment. Test objects include: Emissions, Workplace air, Emission automated measuring systems.
At a glance
- Accreditation number: ČIA 1794
- Methods in scope: 26
- Types of test objects: 3
- City: Dolní Ředice, Czech Republic
- Valid until: 03-09-2031
- Accreditation number
- 1794
- Accreditation body
- ČIA
- Address
- K Třešňovce 247, 533 75 Dolní Ředice
- City
- Dolní Ředice, Czech Republic
- Division
- Laboratorium Pomiarów w Dziedzinie Ochrony Powietrza
- Valid until
- 03-09-2031
What this laboratory tests (3)
- Emissions — 20 methods
- Workplace air — 5 methods
- Emission automated measuring systems — 1 method
Certificate information
- Certificate date
- 03.09.2026
Accreditation scope — test methods (26)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Emissions | Determination of velocity and volumetric flow rate Regulated area: 1 Emissions |
SOP-E-101 (ČSN ISO 10780; ČSN EN 15259; ČSN EN ISO 16911-1) | ||
| 2 | Emissions | Determination of gas moisture (condensation method, adsorption method, capacitive sensor) Regulated area: 1 Emissions |
SOP-E-102 (ČSN EN 14790) | ||
| 3 | Emissions | Determination of volume concentration of oxygen (O2) by automated analysers (paramagnetic method) Regulated area: 1 Emissions |
SOP-E-103, část A (ČSN EN 14789) | ||
| 4 | Emissions | Determination of volume concentration of oxygen (O2) by automated analysers (electrochemical cell method) Regulated area: 1 Emissions |
SOP-E-103, část B (ISO 12039:2019) | ||
| 5 | Emissions | Determination of mass concentration of gaseous pollutants (CO, NO, NO2, N2O, NOx, SO2, CH4) and determination of volume concentration of CO2 by automated analysers (NDIR) carbon monoxide (CO) nitric oxide (NO) nitrogen dioxide (NO2) nitrous oxide (N2O) nitrogen oxides (NOx) sulphur dioxide (SO2) methane (CH4) carbon dioxide (CO2) Regulated area: 1 Emissions |
SOP-E-104, část A (ČSN EN 15058; ČSN ISO 7935; ČSN ISO 10849; ČSN P CEN/TS 17405; ČSN EN ISO 21258; Manuál přístroje MRU MGAPrime) | ||
| 6 | Emissions | Determination of mass concentration of gaseous pollutants (NOx) by automated analysers (chemiluminescence) Regulated area: 1 Emissions |
SOP-E-104, část B (ČSN EN 14792) | ||
| 7 | Emissions | Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) and mass concentration of methane (CH4) by automated analysers (FID) Regulated area: 1 Emissions |
SOP-E-105 (ČSN EN 12619; ČSN EN ISO 25140) | ||
| 8 | Emissions | Determination of mass concentration of volatile organic compounds, carbonyl compounds and amines (VOC) by calculation from measured values Regulated area: 1 Emissions |
SOP-E-106 (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1; EPA Method TO-11A; ČSN P CEN/TS 17638) | ||
| 9 | Emissions | Determination of mass concentration of particulate matter (gravimetry) Regulated area: 1 Emissions |
SOP-E-107 (ČSN EN 13284-1; ČSN EN 15259) | ||
| 10 | Emissions | Determination of mass concentration of metals by calculation from measured values Antimony (Sb) Arsenic (As) Tin (Sn) Chromium (Cr) Cobalt (Co) Cadmium (Cd) Copper (Cu) Manganese (Mn) Nickel (Ni) Lead (Pb) Thallium (Tl) Vanadium (V) Zinc (Zn) Aluminium (Al) Silver (Ag) Iron (Fe) Barium (Ba) Mercury (Hg) Beryllium (Be) Tellurium (Te) Selenium (Se) hexavalent chromium (Cr6+) Regulated area: 1 Emissions |
SOP-E-108 (ČSN EN 14385; ČSN EN 13211; EPA Method 29; ČSN EN 13284-1; ČSN EN 15259; EPA Method 0061) | ||
| 11 | Emissions | Determination of mass concentration of gases and vapours by calculation from measured values hydrogen chloride (HCl) hydrogen fluoride (HF) ammonia (NH3) hydrogen sulphide (H2S) sulphur dioxide (SO2) inorganic acids Regulated area: 1 Emissions |
SOP-E-109 (ČSN EN 1911; ČSN P CEN/TS 17340; ČSN 83 4712-1; ČSN EN ISO 21877; ČSN EN 14791) | ||
| 12 | Emissions | Determination of mass concentration of persistent organic pollutants POPs (PCDD, PCDF, PCB, PAH) by calculation from measured values PCDD (polychlorinated dibenzodioxins) PCDF (polychlorinated dibenzofurans) PCB (polychlorinated biphenyls) PAH (polyaromatic hydrocarbons) Regulated area: 1 Emissions |
SOP-E-111 (ČSN EN 1948-3; ČSN EN 1948-4+A1; ISO 11338-1:2003; ČSN ISO 13284-1; ČSN EN 15259) | ||
| 13 | Emissions | Determination of mass concentration of gaseous pollutants (CO, NO, NO2, N2O, NOx, SO2, CH4) and determination of volume concentration of CO2 by automated analysers (FTIR) carbon monoxide (CO) nitric oxide (NO) nitrogen dioxide (NO2) nitrous oxide (N2O) nitrogen oxides (NOx) sulphur dioxide (SO2) methane (CH4) carbon dioxide (CO2) Regulated area: 1 Emissions |
SOP-E-112 (CEN/TS 17337; ČSN P CEN/TS 17337; Manuál přístroje GASMET DX4000 FTIR) | ||
| 14 | Emission automated measuring systems | Quality assurance of automated measuring systems Regulated area: 1 Emissions |
SOP-E-113 (ČSN EN 14181, čl. 6.3 – 6.8 QAL2, čl. 8 AST; ČSN EN 13284-2) | ||
| 15 | Emissions | Determination of mass concentration of aerosol particle fractions PM10 and PM2.5 (gravimetry) PM10 fraction PM2.5 fraction Regulated area: 1 Emissions |
SOP-E-114 (ČSN EN 12341; ČSN EN ISO 23210) | ||
| 16 | Workplace air | Determination of mass concentration of dust and aerosol (gravimetry) Regulated area: 2 Workplace air |
SOP-P-201 (NV č. 361/2007 Sb.) | ||
| 17 | Workplace air | Determination of mass concentration of gases and vapours by calculation from measured values Regulated area: 2 Workplace air |
SOP-P-202 (NV č. 361/2007 Sb.; ČSN EN ISO 16017-1; ČSN EN 689+AC) | ||
| 18 | Workplace air | Determination of number concentration of mineral and asbestos fibres by calculation from measured values Regulated area: 2 Workplace air |
SOP-P-202 (NV č. 361/2007 Sb.; ČSN EN 689+AC) | ||
| 19 | Emissions | Sampling of particulate matter (isokinetic sampling with manual and automatic control) Regulated area: Sampling |
SOP-EVZ-01 (ČSN EN 13284-1; ČSN EN 15259) | ||
| 20 | Emissions | Sampling for determination of metals (Sb, As, Sn, Cr, Co, Cd, Cu, Mn, Ni, Pb, Tl, V, Zn, Al, Ag, Fe, Ba, Hg, Be, Te, Se, Cr6+) (isokinetic sampling with manual and automatic control) Antimony (Sb) Arsenic (As) Tin (Sn) Chromium (Cr) Cobalt (Co) Cadmium (Cd) Copper (Cu) Manganese (Mn) Nickel (Ni) Lead (Pb) Thallium (Tl) Vanadium (V) Zinc (Zn) Aluminium (Al) Silver (Ag) Iron (Fe) Barium (Ba) Mercury (Hg) Beryllium (Be) Tellurium (Te) Selenium (Se) hexavalent chromium (Cr6+) Regulated area: Sampling |
SOP-EVZ-02 (ČSN EN 14385; ČSN EN 13211; EPA Method 29; ČSN EN 13284-1; ČSN EN 15259; EPA Method 0061) | ||
| 21 | Emissions | Sampling for determination of volatile organic compounds (VOC), carbonyl compounds and amines by collection on a solid sorbent Regulated area: Sampling |
SOP-EVZ-03 (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1; EPA Method TO-11A) | ||
| 22 | Emissions | Sampling of gases and vapours for determination of HCl, HF, NH3, H2S, SO2, inorganic acids and formaldehyde by absorption into liquid hydrogen chloride (HCl) hydrogen fluoride (HF) ammonia (NH3) hydrogen sulphide (H2S) sulphur dioxide (SO2) inorganic acids formaldehyde Regulated area: Sampling |
SOP-EVZ-04 (ČSN EN 1911; ČSN P CEN/TS 17340; ČSN 83 4712-2; ČSN EN ISO 21877; ČSN EN 14791; ČSN P CEN/TS 17638) | ||
| 23 | Workplace air | Sampling on a solid sorbent (filter, PUF, sorption tube) Regulated area: Sampling |
SOP-PVZ-05 (NV č. 361/2007 Sb.; ČSN EN ISO 16017-1; ČSN EN 689+AC) | ||
| 24 | Workplace air | Sampling for determination of HCl, HF, NH3, H2S, inorganic acids into liquid (sorption solution) hydrogen chloride (HCl) hydrogen fluoride (HF) ammonia (NH3) hydrogen sulphide (H2S) inorganic acids Regulated area: Sampling |
SOP-PVZ-06 (NV č. 361/2007 Sb.) | ||
| 25 | Emissions | Sampling for determination of persistent organic pollutants POPs (PCDD, PCDF, PCB and PAH) by the filter/condenser method (isokinetic sampling with manual and automatic control) PCDD (polychlorinated dibenzodioxins) PCDF (polychlorinated dibenzofurans) PCB (polychlorinated biphenyls) PAH (polyaromatic hydrocarbons) Regulated area: Sampling |
SOP-EVZ-07 (ČSN EN 1948-1; ČSN EN 1948-4+A1; ISO 11338-1:2003; ČSN ISO 13284-1; ČSN EN 15259) | ||
| 26 | Emissions | Sampling for determination of mass concentration of aerosol particle fractions PM10 and PM2.5 Regulated area: Sampling |
SOP-EVZ-07 (ČSN EN 12341; ČSN EN ISO 23210) | ||
Reference standards (66)
CEN/TS 17337
EPA Method 0061
EPA Method 29
EPA Method TO-11A
ISO 11338-1:2003
ISO 12039:2019
Manuál přístroje GASMET DX4000 FTIR
Manuál přístroje MRU MGAPrime
NV č. 361/2007 Sb.
SOP-E-101
SOP-E-102
SOP-E-103
SOP-E-104
SOP-E-105
SOP-E-106
SOP-E-107
SOP-E-108
SOP-E-109
SOP-E-111
SOP-E-112
SOP-E-113
SOP-E-114
SOP-EVZ-01
SOP-EVZ-02
SOP-EVZ-03
SOP-EVZ-04
SOP-EVZ-07
SOP-P-201
SOP-P-202
SOP-PVZ-05
SOP-PVZ-06
ČSN 83 4712-1
ČSN 83 4712-2
ČSN EN 12341
ČSN EN 12619
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 13284-2
ČSN EN 14181, čl. 6.3 – 6.8 QAL2, čl. 8 AST
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 14791
ČSN EN 14792
ČSN EN 15058
ČSN EN 15259
ČSN EN 1911
ČSN EN 1948-1
ČSN EN 1948-3
ČSN EN 1948-4+A1
ČSN EN 689+AC
ČSN EN ISO 16017-1
ČSN EN ISO 16911-1
ČSN EN ISO 21258
ČSN EN ISO 21877
ČSN EN ISO 23210
ČSN EN ISO 25140
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 13284-1
ČSN ISO 7935
ČSN P CEN/TS 13649
ČSN P CEN/TS 17337
ČSN P CEN/TS 17340
ČSN P CEN/TS 17405
ČSN P CEN/TS 17638