🇨🇿 OPTOKON, a.s. PL

ČIA 1755 • 586 01 Jihlava, Czech Republic • 10 methods

Electronics & EMC

OPTOKON, a.s. is a laboratory accredited by ČIA under number 1755 (586 01 Jihlava, Czech Republic). Its accreditation scope covers 10 test methods in the following areas: Electronics & EMC. Test objects include: Electrical and electronic equipment, vehicle assemblies and subasse…, Optical cables and fibres, Optical cables.

At a glance

  • Accreditation number: ČIA 1755
  • Methods in scope: 10
  • Types of test objects: 3
  • City: 586 01 Jihlava, Czech Republic
  • Valid until: 26-10-2028
Accreditation number
1755
Accreditation body
ČIA
Address
Červený Kříž 250, 586 01 Jihlava
City
586 01 Jihlava, Czech Republic
Division
Laboratorium Badawcze OPTOKON
Valid until
26-10-2028

What this laboratory tests (3)

Certificate information

Certificate date
11.02.2026

Accreditation scope — test methods (10)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Optical cables and fibres Temperature cycling resistance test PPZL 2.11 (ČSN EN 60794-1-22, metoda F1)
2 Optical cables and fibres Ageing resistance test PPZL 2.12 (ČSN EN 60794-1-22, metoda F9)
3 Optical cables External freezing resistance test PPZL 2.13 (ČSN EN 60794-1-22, metoda F15)
4 Electrical and electronic equipment, vehicle assemblies and subassemblies, aircraft on-board equipment Conducted emissions, radio frequency potential, power leads MIL-STD-461 met. CE102; ČOS 599902 met. CE102
5 Electrical and electronic equipment, vehicle assemblies and subassemblies, aircraft on-board equipment Radiated emissions, electric field MIL-STD-461 met. RE102; ČOS 599902 met. RE102; ČSN EN IEC 55025 ed.4, čl. 6.4 a 6.5; CISPR 25:2021, čl. 6.4 a 6.5
6 Electrical and electronic equipment, vehicle assemblies and subassemblies, aircraft on-board equipment Conducted susceptibility, power leads MIL-STD-461 met. CS101; ČOS 599902 met. CS101
7 Electrical and electronic equipment, vehicle assemblies and subassemblies, aircraft on-board equipment Conducted susceptibility, bulk cable injection MIL-STD-461 met. CS114; ČOS 599902 met. CS114
8 Electrical and electronic equipment, vehicle assemblies and subassemblies, aircraft on-board equipment Conducted susceptibility, bulk cable injection, impulse excitation MIL-STD-461 met. CS115; ČOS 599902 met. CS115
9 Electrical and electronic equipment, vehicle assemblies and subassemblies, aircraft on-board equipment Conducted susceptibility, damped sinusoid, cables and power leads MIL-STD-461 met. CS116; ČOS 599902 met. CS116
10 Electrical and electronic equipment, vehicle assemblies and subassemblies, aircraft on-board equipment Radiated susceptibility, transient electromagnetic field MIL-STD-461 met. RS103; ČOS 599902 met. RS103

Reference standards (22)

CISPR 25:2021, čl. 6.4 a 6.5
MIL-STD-461 met. CE102
MIL-STD-461 met. CS101
MIL-STD-461 met. CS114
MIL-STD-461 met. CS115
MIL-STD-461 met. CS116
MIL-STD-461 met. RE102
MIL-STD-461 met. RS103
PPZL 2.11
PPZL 2.12
PPZL 2.13
ČOS 599902 met. CE102
ČOS 599902 met. CS101
ČOS 599902 met. CS114
ČOS 599902 met. CS115
ČOS 599902 met. CS116
ČOS 599902 met. RE102
ČOS 599902 met. RS103
ČSN EN 60794-1-22, metoda F1
ČSN EN 60794-1-22, metoda F15
ČSN EN 60794-1-22, metoda F9
ČSN EN IEC 55025 ed.4, čl. 6.4 a 6.5

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1755