🇨🇿 Ademco CZ s.r.o. PL
Electronics & EMC
Ademco CZ s.r.o. is a laboratory accredited by ČIA under number 1695 (Brno, Czech Republic). Its accreditation scope covers 140 test methods in the following areas: Electronics & EMC. Test objects include: Short range devices, Wideband spread-spectrum equipment, Automatic electrical controls, Intentional radiators (FCC part 15, Subpart C).
At a glance
- Accreditation number: ČIA 1695
- Methods in scope: 140
- Types of test objects: 21
- City: Brno, Czech Republic
- Valid until: 16-02-2029
- Accreditation number
- 1695
- Accreditation body
- ČIA
- Address
- Tuřanka 1460/106a, 627 00 Brno
- City
- Brno, Czech Republic
- Division
- Laboratorium Badawcze
- Valid until
- 16-02-2029
What this laboratory tests (21)
- Short range devices — 31 methods
- Wideband spread-spectrum equipment — 12 methods
- Automatic electrical controls — 11 methods
- Intentional radiators (FCC part 15, Subpart C) — 11 methods
- Automatic burner control systems for gaseous or liquid fuel appliances — 9 methods
- Electrical and electronic equipment for residential, commercial, light-industrial and industrial environments — 9 methods
- Electrical apparatus for the detection and measurement of combustible or toxic gases or oxygen — 9 methods
- Radio equipment and services — 8 methods
- Wideband data transmission equipment — 8 methods
- Household electrical appliances, gas appliances — 7 methods
- Alarm systems — 6 methods
- Electrical and electronic equipment — 4 methods
- Household appliances, electric tools and similar apparatus — 2 methods
- Industrial, scientific and medical equipment — 2 methods
- Intentional radiators — 2 methods
- and 6 more
Certificate information
- Certificate date
- 20.11.2025
Accreditation scope — test methods (140)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Industrial, scientific and medical equipment | Conducted emission measurement Regulated area: 1 Conducted emissions |
EN 55011, čl. 6.2.1, 6.3.1, 8.2 | ||
| 2 | Multimedia equipment | Conducted emission measurement Regulated area: 1 Conducted emissions |
EN 55032, příl. A3, C3, C4 | ||
| 3 | Household appliances, electric tools and similar apparatus | Conducted emission measurement Regulated area: 1 Conducted emissions |
EN 55014-1, čl. 5.2 | ||
| 4 | Electrical and electronic equipment for residential, commercial, light-industrial and industrial environments | Conducted emission measurement Regulated area: 1 Conducted emissions |
EN 61000-6-3, čl. 11, tab. 4, položka 4.3, 4.4, tab. 5, tab. 6; EN 61000-6-4, tab. 4, 5, A.1; EN 55016-2-1; EN 55016-2-2 | ||
| 5 | Unintentional radiators (FCC part 15, Subpart B) | Conducted emission measurement Regulated area: 1 Conducted emissions |
ANSI C63.4:2014, čl. 7 | ||
| 6 | Intentional radiators (FCC part 15, Subpart C) | Conducted emission measurement Regulated area: 1 Conducted emissions |
ANSI C63.10:2013, čl. 6.2; ANSI C63.10, čl. 6.2 | ||
| 7 | Radio equipment and services | Conducted emission measurement Regulated area: 1 Conducted emissions |
ETSI EN 301 489-1, čl. 8.3, 8.4, 8.5, 8.6, 8.7 | ||
| 8 | Short range devices | Conducted emission measurement Regulated area: 1 Conducted emissions |
ETSI EN 301 489-3, čl. 7.1 | ||
| 9 | Wideband data transmission equipment | Conducted emission measurement Regulated area: 1 Conducted emissions |
ETSI EN 301 489-17, čl. 7.1 | ||
| 10 | Electrical apparatus for the detection and measurement of combustible or toxic gases or oxygen | Conducted emission measurement Regulated area: 1 Conducted emissions |
EN 50270, čl. 6, mimo rozsah 0 kHz – 2 kHz | ||
| 11 | Automatic electrical controls | Conducted emission measurement Regulated area: 1 Conducted emissions |
EN 60730-2-5, čl. 23; EN 60730-1:2011, čl. 23, příl. H23, mimo rozsah 0 kHz – 2 kHz; EN 60730-1, čl. 23, příl. H23, mimo rozsah 0 kHz – 2 kHz | ||
| 12 | Industrial, scientific and medical equipment | Radiated emission measurement Regulated area: 2 Radiated emissions |
EN 55011, čl. 6.2.2, 6.3.2, 8.3, 8.4, 9 | ||
| 13 | Multimedia equipment | Radiated emission measurement Regulated area: 2 Radiated emissions |
EN 55032, příl. A2, C3, C4 | ||
| 14 | Household appliances, electric tools and similar apparatus | Radiated emission measurement Regulated area: 2 Radiated emissions |
EN 55014-1, čl. 5.3 | ||
| 15 | Electrical and electronic equipment for residential, commercial, light-industrial and industrial environments | Radiated emission measurement Regulated area: 2 Radiated emissions |
EN 61000-6-3, čl. 11, tab. 3, položky 3.1, 3.3, 3.4; EN 61000-6-4, čl. 9, tab. 3, položky 3.1, 3.3, 3.4; EN 55016-2-3 | ||
| 16 | Unintentional radiators (FCC part 15, Subpart B) | Radiated emission measurement Regulated area: 2 Radiated emissions |
ANSI C63.4:2014, čl. 8 | ||
| 17 | Intentional radiators (FCC part 15, Subpart C) | Radiated emission measurement Regulated area: 2 Radiated emissions |
ANSI C63.10:2013, čl. 6.3, 6.4, 6.5, 6.6; ANSI C63.10, čl. 6.3, 6.4, 6.5, 6.6 | ||
| 18 | Radio equipment and services | Radiated emission measurement Regulated area: 2 Radiated emissions |
ETSI EN 301 489-1, čl. 8.2 | ||
| 19 | Short range devices | Radiated emission measurement Regulated area: 2 Radiated emissions |
ETSI EN 301 489-3, čl. 7.1 | ||
| 20 | Wideband data transmission equipment | Radiated emission measurement Regulated area: 2 Radiated emissions |
ETSI EN 301 489-17, čl. 7.1 | ||
| 21 | Electrical apparatus for the detection and measurement of combustible or toxic gases or oxygen | Radiated emission measurement Regulated area: 2 Radiated emissions |
EN 50270, čl. 6 | ||
| 22 | Automatic electrical controls | Radiated emission measurement Regulated area: 2 Radiated emissions |
EN 60730-2-5, čl. 23; EN 60730-1:2011, čl. 23, příl. H23; EN 60730-1, čl. 23, příl. H23 | ||
| 23 | Electrical and electronic equipment for residential, commercial, light-industrial and industrial environments | Electrostatic discharge immunity test Regulated area: 3 Electrostatic discharge immunity |
EN 61000-4-2; EN 61000-6-1, tab. 1, položka 1.4; EN 61000-6-2, tab. 1, položka 1.4 | ||
| 24 | Radio equipment and services | Electrostatic discharge immunity test Regulated area: 3 Electrostatic discharge immunity |
ETSI EN 301 489-1, čl. 9.3 | ||
| 25 | Short range devices | Electrostatic discharge immunity test Regulated area: 3 Electrostatic discharge immunity |
ETSI EN 301 489-3, čl. 7.2 | ||
| 26 | Wideband data transmission equipment | Electrostatic discharge immunity test Regulated area: 3 Electrostatic discharge immunity |
ETSI EN 301 489-17, čl. 7.2 | ||
| 27 | Automatic burner control systems for gaseous or liquid fuel appliances | Electrostatic discharge immunity test Regulated area: 3 Electrostatic discharge immunity |
EN 298:2012, čl. 8.9; EN 298, čl. 9.9; EN 13611:2007+A2:2011, čl. 8.9; EN 13611, čl. 9.9 | ||
| 28 | Automatic electrical controls | Electrostatic discharge immunity test Regulated area: 3 Electrostatic discharge immunity |
EN 60730-2-5, příl. H.26.11; EN 60730-1:2011, čl. 26, příl. H.26.11; EN 60730-1, čl. 26, příl. H.26.11 | ||
| 29 | Alarm systems | Electrostatic discharge immunity test Regulated area: 3 Electrostatic discharge immunity |
EN 50130-4, čl. 9 | ||
| 30 | Household electrical appliances, gas appliances | Electrostatic discharge immunity test Regulated area: 3 Electrostatic discharge immunity |
EN 60335-1, čl. 19.11.4.1; EN 60335-2-102, čl. 19 | ||
| 31 | Electrical apparatus for the detection and measurement of combustible or toxic gases or oxygen | Electrostatic discharge immunity test Regulated area: 3 Electrostatic discharge immunity |
EN 50270, čl. 5, tab. 1, položka 1.5 | ||
| 32 | Electrical and electronic equipment for residential, commercial, light-industrial and industrial environments | Radiated radio-frequency electromagnetic field immunity test Regulated area: 4 Radiated RF field immunity |
EN 61000-4-3; EN 61000-6-1, tab. 1, položky 1.2, 1.3; EN 61000-6-2, tab. 1, položky 1.2, 1.3 | ||
| 33 | Radio equipment and services | Radiated radio-frequency electromagnetic field immunity test Regulated area: 4 Radiated RF field immunity |
ETSI EN 301 489-1, čl. 9.2 | ||
| 34 | Short range devices | Radiated radio-frequency electromagnetic field immunity test Regulated area: 4 Radiated RF field immunity |
ETSI EN 301 489-3, čl. 7.2 | ||
| 35 | Wideband data transmission equipment | Radiated radio-frequency electromagnetic field immunity test Regulated area: 4 Radiated RF field immunity |
ETSI EN 301 489-17, čl. 7.2 | ||
| 36 | Automatic burner control systems for gaseous or liquid fuel appliances | Radiated radio-frequency electromagnetic field immunity test Regulated area: 4 Radiated RF field immunity |
EN 298:2012, čl. 8.8; EN 298, čl. 9.8; EN 13611:2007+A2:2011, čl. 8.8; EN 13611, čl. 9.8 | ||
| 37 | Automatic electrical controls | Radiated radio-frequency electromagnetic field immunity test Regulated area: 4 Radiated RF field immunity |
EN 60730-2-5, příl. H.26.12.3; EN 60730-1:2011, čl. 26, příl. H.26.12.3; EN 60730-1, čl. 26, příl. H.26.12.3 | ||
| 38 | Alarm systems | Radiated radio-frequency electromagnetic field immunity test Regulated area: 4 Radiated RF field immunity |
EN 50130-4, čl. 10 | ||
| 39 | Household electrical appliances, gas appliances | Radiated radio-frequency electromagnetic field immunity test Regulated area: 4 Radiated RF field immunity |
EN 60335-1, čl. 19.11.4.2; EN 60335-2-102, čl. 19 | ||
| 40 | Electrical apparatus for the detection and measurement of combustible or toxic gases or oxygen | Radiated radio-frequency electromagnetic field immunity test Regulated area: 4 Radiated RF field immunity |
EN 50270, čl. 5, tab. 1, položka 1.2, 1.3, 1,4 | ||
| 41 | Electrical and electronic equipment for residential, commercial, light-industrial and industrial environments | Electrical fast transient/burst immunity test Regulated area: 5 Electrical fast transient immunity |
EN 61000-4-4; EN 61000-6-1, tab. 2, položka 2.3, tab. 3, položka 3.3, tab. 4, položka 4.5; EN 61000-6-2, tab. 2, položka 2.3, tab. 3, položka 3.3, tab. 4, položka 4.5 | ||
| 42 | Radio equipment and services | Electrical fast transient/burst immunity test Regulated area: 5 Electrical fast transient immunity |
ETSI EN 301 489-1, čl. 9.4 | ||
| 43 | Short range devices | Electrical fast transient/burst immunity test Regulated area: 5 Electrical fast transient immunity |
ETSI EN 301 489-3, čl. 7.2 | ||
| 44 | Wideband data transmission equipment | Electrical fast transient/burst immunity test Regulated area: 5 Electrical fast transient immunity |
ETSI EN 301 489-17, čl. 7.2 | ||
| 45 | Automatic burner control systems for gaseous or liquid fuel appliances | Electrical fast transient/burst immunity test Regulated area: 5 Electrical fast transient immunity |
EN 298:2012, čl. 8.6; EN 298, čl. 9.6; EN 13611:2007+A2:2011, čl. 8.6; EN 13611, čl. 9.6 | ||
| 46 | Automatic electrical controls | Electrical fast transient/burst immunity test Regulated area: 5 Electrical fast transient immunity |
EN 60730-2-5, příl. H.26.9; EN 60730-1:2011, čl. 26, příl. H.26.9; EN 60730-1, čl. 26, příl. H.26.9 | ||
| 47 | Alarm systems | Electrical fast transient/burst immunity test Regulated area: 5 Electrical fast transient immunity |
EN 50130-4, čl. 12 | ||
| 48 | Household electrical appliances, gas appliances | Electrical fast transient/burst immunity test Regulated area: 5 Electrical fast transient immunity |
EN 60335-1, čl. 19.11.4.3; EN 60335-2-102, čl. 19 | ||
| 49 | Electrical apparatus for the detection and measurement of combustible or toxic gases or oxygen | Electrical fast transient/burst immunity test Regulated area: 5 Electrical fast transient immunity |
EN 50270, čl. 5, tab. 2, položka 2.2, tab. 3, položka 3.3, tab. 4, položka 4.5 | ||
| 50 | Electrical and electronic equipment for residential, commercial, light-industrial and industrial environments | Surge immunity test Regulated area: 6 Surge immunity |
EN 61000-4-5; EN 61000-6-1, tab. 2, položka 2.2, tab. 3, položka 3.2, tab. 4, položka 4.4; EN 61000-6-2, tab. 2, položka 2.2, tab. 3, položka 3.2, tab. 4, položka 4.4 | ||
| 51 | Radio equipment and services | Surge immunity test Regulated area: 6 Surge immunity |
ETSI EN 301 489-1, čl. 9.8 | ||
| 52 | Short range devices | Surge immunity test Regulated area: 6 Surge immunity |
ETSI EN 301 489-3, čl. 7.2 | ||
| 53 | Wideband data transmission equipment | Surge immunity test Regulated area: 6 Surge immunity |
ETSI EN 301 489-17, čl. 7.2 | ||
| 54 | Automatic burner control systems for gaseous or liquid fuel appliances | Surge immunity test Regulated area: 6 Surge immunity |
EN 298:2012, čl. 8.5; EN 298, čl. 9.5; EN 13611:2007+A2:2011, čl. 8.5; EN 13611, čl. 9.5 | ||
| 55 | Automatic electrical controls | Surge immunity test Regulated area: 6 Surge immunity |
EN 60730-2-5, příl. H.26.8; EN 60730-1:2011, čl. 26, příl. H.26.8; EN 60730-1, čl. 26, příl. H.26.8 | ||
| 56 | Alarm systems | Surge immunity test Regulated area: 6 Surge immunity |
EN 50130-4, čl. 13 | ||
| 57 | Household electrical appliances, gas appliances | Surge immunity test Regulated area: 6 Surge immunity |
EN 60335-1, čl. 19.11.4.4; EN 60335-2-102, čl. 19 | ||
| 58 | Electrical apparatus for the detection and measurement of combustible or toxic gases or oxygen | Surge immunity test Regulated area: 6 Surge immunity |
EN 50270, tab. 2, položka 2.3, tab. 3, položka 3.2, tab. 4, položka 4.4 | ||
| 59 | Electrical and electronic equipment for residential, commercial, light-industrial and industrial environments | Immunity to conducted disturbances induced by radio-frequency fields Regulated area: 7 Immunity to conducted disturbances induced by RF fields |
EN 61000-4-6; EN 61000-6-1, tab. 2, položka 2.1, tab. 3, položka 3.1, tab. 4, položka 4.1; EN 61000-6-2, tab. 2, položka 2.1, tab. 3, položka 3.1, tab. 4, položka 4.1 | ||
| 60 | Radio equipment and services | Immunity to conducted disturbances induced by radio-frequency fields Regulated area: 7 Immunity to conducted disturbances induced by RF fields |
ETSI EN 301 489-1, čl. 9.5 | ||
| 61 | Short range devices | Immunity to conducted disturbances induced by radio-frequency fields Regulated area: 7 Immunity to conducted disturbances induced by RF fields |
ETSI EN 301 489-3, čl. 7.2 | ||
| 62 | Wideband data transmission equipment | Immunity to conducted disturbances induced by radio-frequency fields Regulated area: 7 Immunity to conducted disturbances induced by RF fields |
ETSI EN 301 489-17, čl. 7.2 | ||
| 63 | Automatic burner control systems for gaseous or liquid fuel appliances | Immunity to conducted disturbances induced by radio-frequency fields Regulated area: 7 Immunity to conducted disturbances induced by RF fields |
EN 298:2012, čl. 8.7; EN 298, čl. 9.7; EN 13611:2007+A2:2011, čl. 8.7; EN 13611, čl. 9.7 | ||
| 64 | Automatic electrical controls | Immunity to conducted disturbances induced by radio-frequency fields Regulated area: 7 Immunity to conducted disturbances induced by RF fields |
EN 60730-2-5, příl. H.26.12.2.1; EN 60730-1:2011, čl. 26, příl. H.26.12.2; EN 60730-1, čl. 26, příl. H.26.12.2 | ||
| 65 | Alarm systems | Immunity to conducted disturbances induced by radio-frequency fields Regulated area: 7 Immunity to conducted disturbances induced by RF fields |
EN 50130-4, čl. 11 | ||
| 66 | Household electrical appliances, gas appliances | Immunity to conducted disturbances induced by radio-frequency fields Regulated area: 7 Immunity to conducted disturbances induced by RF fields |
EN 60335-1, čl. 19.11.4.5; EN 60335-2-102, čl. 19 | ||
| 67 | Electrical apparatus for the detection and measurement of combustible or toxic gases or oxygen | Immunity to conducted disturbances induced by radio-frequency fields Regulated area: 7 Immunity to conducted disturbances induced by RF fields |
EN 50270, tab. 2, položka 2.1, tab. 3, položka 3.1, tab. 4, položka 4.1 | ||
| 68 | Electrical and electronic equipment for residential, commercial, light-industrial and industrial environments | Power frequency magnetic field immunity test Regulated area: 8 Magnetic field immunity |
EN 61000-4-8; EN 61000-6-1, tab. 1, položka 1.1; EN 61000-6-2, tab. 1, položka 1.1 | ||
| 69 | Automatic burner control systems for gaseous or liquid fuel appliances | Power frequency magnetic field immunity test Regulated area: 8 Magnetic field immunity |
EN 298:2012, čl. 8.10; EN 298, čl. 9.10; EN 13611:2007+A2:2011, čl. 8.10; EN 13611, čl. 9.10 | ||
| 70 | Automatic electrical controls | Power frequency magnetic field immunity test Regulated area: 8 Magnetic field immunity |
EN 60730-2-5, příl. H.26.14; EN 60730-1:2011, čl. 26, příl. H.26.14; EN 60730-1, čl. 26, příl. H.26.14 | ||
| 71 | Electrical and electronic equipment | Pulse magnetic field immunity test Regulated area: 8 Magnetic field immunity |
EN 61000-4-9 | ||
| 72 | Electrical apparatus for the detection and measurement of combustible or toxic gases or oxygen | Power frequency magnetic field immunity test Regulated area: 8 Magnetic field immunity |
EN 50270, tab. 1, položka 1.1 | ||
| 73 | Electrical and electronic equipment for residential, commercial, light-industrial and industrial environments | Voltage dips, short interruptions and voltage variations immunity test Regulated area: 9 Voltage dips, short interruptions and variations immunity |
EN 61000-4-11; EN 61000-6-1, tab. 4, položka 4.2, 4.3; EN 61000-6-2, tab. 4, položka 4.2, 4.3 | ||
| 74 | Radio equipment and services | Voltage dips, short interruptions and voltage variations immunity test Regulated area: 9 Voltage dips, short interruptions and variations immunity |
ETSI EN 301 489-1, čl. 9.7 | ||
| 75 | Short range devices | Voltage dips, short interruptions and voltage variations immunity test Regulated area: 9 Voltage dips, short interruptions and variations immunity |
ETSI EN 301 489-3, čl. 7.2 | ||
| 76 | Wideband data transmission equipment | Voltage dips, short interruptions and voltage variations immunity test Regulated area: 9 Voltage dips, short interruptions and variations immunity |
ETSI EN 301 489-17, čl. 7.2 | ||
| 77 | Automatic burner control systems for gaseous or liquid fuel appliances | Voltage dips, short interruptions and voltage variations immunity test Regulated area: 9 Voltage dips, short interruptions and variations immunity |
EN 298:2012, čl. 8.2, 8.3; EN 298, čl. 9.2, 9.3; EN 13611:2007+A2:2011, čl. 8.2, 8.3; EN 13611, čl. 9.2, 9.3 | ||
| 78 | Automatic electrical controls | Voltage dips, short interruptions and voltage variations immunity test Regulated area: 9 Voltage dips, short interruptions and variations immunity |
EN 60730-2-5, příl. H.26.5; EN 60730-1:2011, čl. 26, příl. H.26.5; EN 60730-1, čl. 26, příl. H.26.5 | ||
| 79 | Alarm systems | Voltage dips, short interruptions and voltage variations immunity test Regulated area: 9 Voltage dips, short interruptions and variations immunity |
EN 50130-4, čl. 7, 8 | ||
| 80 | Household electrical appliances, gas appliances | Voltage dips, short interruptions and voltage variations immunity test for equipment up to 16 A Regulated area: 9 Voltage dips, short interruptions and variations immunity |
EN 60335-1, čl. 19.11.4.6 do 16 A, 19.11.4.8; EN 60335-2-102, čl. 19 | ||
| 81 | Electrical apparatus for the detection and measurement of combustible or toxic gases or oxygen | Voltage dips, short interruptions and voltage variations immunity test Regulated area: 9 Voltage dips, short interruptions and variations immunity |
EN 50270, tab. 4, položka 4.2, 4.3 | ||
| 82 | Electrical and electronic equipment | Damped oscillatory wave immunity test Regulated area: 10 Damped oscillatory wave immunity |
EN 61000-4-12 | ||
| 83 | Electrical and electronic equipment | Variation of power frequency immunity test Regulated area: 11 Variation of power frequency immunity |
EN 61000-4-28 | ||
| 84 | Automatic burner control systems for gaseous or liquid fuel appliances | Variation of power frequency immunity test Regulated area: 11 Variation of power frequency immunity |
EN 298:2012, čl. 8.4; EN 298, čl. 9.4; EN 13611:2007+A2:2011, čl. 8.4; EN 13611, čl. 9.4 | ||
| 85 | Automatic electrical controls | Variation of power frequency immunity test Regulated area: 11 Variation of power frequency immunity |
EN 60730-2-5, příl. H.26.13; EN 60730-1:2011, čl. 26, příl. H.26.13; EN 60730-1, čl. 26, příl. H.26.13 | ||
| 86 | Short range devices | Power measurement (at the antenna connector), Tx-sequence, Tx-gap, Medium Utilization Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.2 | ||
| 87 | Wideband spread-spectrum equipment | Power measurement (at the antenna connector), Tx-sequence, Tx-gap, Medium Utilization Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 328 čl. 5.4.2; ETSI EN 301 893, čl. 5.4.4 | ||
| 88 | Short range devices | Measurement of effective radiated power Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.2 | ||
| 89 | Short range devices | Measurement of maximum power spectral density Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.3 | ||
| 90 | Wideband spread-spectrum equipment | Measurement of maximum power spectral density Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 328, čl. 5.4.3; ETSI EN 301 893, čl. 4.2.3 | ||
| 91 | Short range devices | Duty cycle measurement Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.4, 5.5; ETSI EN 300 440, čl. 4.2.5 | ||
| 92 | Wideband spread-spectrum equipment | Duty cycle measurement Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 328, čl. 5.4.2 | ||
| 93 | Short range devices | Measurement of occupied bandwidth Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.6; ETSI EN 300 440, čl. 4.2.3 | ||
| 94 | Wideband spread-spectrum equipment | Measurement of occupied bandwidth Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 328, čl. 5.4.7; ETSI EN 301 893, čl. 5.4.3 | ||
| 95 | Short range devices | Measurement of frequency error Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.7 | ||
| 96 | Short range devices | Measurement of transmitter unwanted emissions Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.8, 5.9; ETSI EN 300 440, čl. 4.2.4 | ||
| 97 | Wideband spread-spectrum equipment | Measurement of transmitter unwanted emissions Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 328, čl. 5.4.8, 5.4.9; ETSI EN 301 893, čl. 5.4.5, 5.4.6 | ||
| 98 | Global system for mobile communications, mobile station equipment | Measurement of transmitter unwanted emissions Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI TS 151 010-1, čl. 12.2, 12.4 | ||
| 99 | Short range devices | Measurement of receiver spurious emissions Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.9; ETSI EN 300 440, čl. 4.3.5 | ||
| 100 | Wideband spread-spectrum equipment | Measurement of receiver spurious emissions Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 328, čl. 5.4.10; ETSI EN 301 893, čl. 5.4.7 | ||
| 101 | Short range devices | Measurement of transmitter transient behaviour Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.10 | ||
| 102 | Short range devices | Measurement of adjacent channel power Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.11 | ||
| 103 | Short range devices | Measurement of frequency stability under low voltage conditions Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.12 | ||
| 104 | Short range devices | Adaptive power control Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.13 | ||
| 105 | Short range devices | Measurement of maximum usable sensitivity Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.14 | ||
| 106 | Short range devices | Measurement of adjacent channel selectivity Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.15; ETSI EN 300 440, čl. 4.3.3 | ||
| 107 | Short range devices | Receiver saturation at adjacent channel Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.16 | ||
| 108 | Short range devices | Measurement of spurious response rejection Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.17 | ||
| 109 | Short range devices | Measurement of blocking or desensitisation and immunity to unmodulated interference Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.18; ETSI EN 300 440, čl. 4.3.4 | ||
| 110 | Wideband spread-spectrum equipment | Measurement of blocking or desensitisation and immunity to unmodulated interference Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 301 893, čl. 5.4.10; ETSI EN 300 328, čl. 5.4.11 | ||
| 111 | Short range devices | Receiver behaviour at high received signal level Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.19 | ||
| 112 | Short range devices | Measurement of receiver threshold and transmission timing parameters Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.21 | ||
| 113 | Short range devices | Verification of correct reception of acknowledgement between receiver and transmitter Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 220-1, čl. 5.22 | ||
| 114 | Wideband spread-spectrum equipment | Accumulated transmit time, frequency occupation, frequency hopping Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 328, čl. 5.4.4 | ||
| 115 | Short range devices | Accumulated transmit time, frequency occupation, frequency hopping Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 440, čl. 4.2.6 | ||
| 116 | Wideband spread-spectrum equipment | Hopping frequency separation Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 328, čl. 5.4.5 | ||
| 117 | Short range devices | Hopping frequency separation Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 440, čl. 4.2.6 | ||
| 118 | Wideband spread-spectrum equipment | Receiver adaptivity Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 328, čl. 5.4.6; ETSI EN 301 893, čl. 5.4.9 | ||
| 119 | Short range devices | Measurement of equivalent isotropically radiated power Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 440, čl. 4.2.2 | ||
| 120 | Wideband spread-spectrum equipment | Measurement of equivalent isotropically radiated power Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 300 328, čl. 5.3.2; ETSI EN 301 893, čl. 5.4.4 | ||
| 121 | Wideband spread-spectrum equipment | Frequency measurement Regulated area: 12 Radio parameters measured by ETSI methods |
ETSI EN 301 893, čl. 5.4.2 | ||
| 122 | Intentional radiators (FCC part 15, Subpart C) | Power measurement (at the antenna connector) Regulated area: 13 Radio parameters measured by ANSI methods |
ANSI C63.10:2013, čl. 7.8.5, 11.9,12.3.2, 12.6; ANSI C63.10, čl. 7.8.5, 11.9, 12.4.2 | ||
| 123 | Intentional radiators (FCC part 15, Subpart C) | Measurement of transmitter unwanted emissions at the band edge Regulated area: 13 Radio parameters measured by ANSI methods |
ANSI C63.10:2013, čl. 6.10.4, 6.10.5, 6.10.6., 7.8.6, 7.8.8, 11.11, 11.12, 11.13; ANSI C63.10, čl. 6.10.4, 6.10.5, 6.10.6., 7.8.8, 11.11, 11.12, 11.13 | ||
| 124 | Intentional radiators (FCC part 15, Subpart C) | Measurement of occupied bandwidth Regulated area: 13 Radio parameters measured by ANSI methods |
ANSI C63.10:2013, čl. 6.9.2, 6.9.3, 11.8, 12.4; ANSI C63.10, čl. 6.9.2, 6.9.3, 11.8, 12.5 | ||
| 125 | Intentional radiators (FCC part 15, Subpart C) | Measurement of maximum power spectral density Regulated area: 13 Radio parameters measured by ANSI methods |
ANSI C63.10:2013, čl. 11.10.2, 12.5; ANSI C63.10, čl. 11.10.2, 12.6 | ||
| 126 | Intentional radiators (FCC part 15, Subpart C) | Measurement of unwanted emissions – conducted Regulated area: 13 Radio parameters measured by ANSI methods |
ANSI C63.10:2013, čl. 6.7, 7.8.8, 11.12.2; ANSI C63.10, čl. 6.7, 7.8.7, 11.12.2 | ||
| 127 | Intentional radiators (FCC part 15, Subpart C) | Measurement of unwanted emissions – radiated Regulated area: 13 Radio parameters measured by ANSI methods |
ANSI C63.10:2013, čl. 11.11, 6.3, 6.5, 6.6, 12.7; ANSI C63.10, čl. 11.11, 6.3, 6.5, 6.6, 12.7, 12.8 | ||
| 128 | Intentional radiators (FCC part 15, Subpart C) | Measurement of carrier frequency separation Regulated area: 13 Radio parameters measured by ANSI methods |
ANSI C63.10:2013, čl. 7.8.2; ANSI C63.10, čl. 7.8.2 | ||
| 129 | Intentional radiators (FCC part 15, Subpart C) | Measurement of the number of hopping frequencies Regulated area: 13 Radio parameters measured by ANSI methods |
ANSI C63.10:2013, čl. 7.8.3; ANSI C63.10, čl. 7.8.3 | ||
| 130 | Intentional radiators (FCC part 15, Subpart C) | Measurement of dwell time on a single carrier frequency Regulated area: 13 Radio parameters measured by ANSI methods |
ANSI C63.10:2013, čl. 7.8.4, 11.6; ANSI C63.10, čl. 7.8.4, 11.6 | ||
| 131 | Intentional radiators | Duty cycle measurement Regulated area: 13 Radio parameters measured by ANSI methods |
ANSI C63.10:2013, čl. 11.6, 12.2; ANSI C63.10, čl. 11.6, 12.2 | ||
| 132 | Intentional radiators | Measurement of frequency stability Regulated area: 13 Radio parameters measured by ANSI methods |
ANSI C63.10:2013, čl. 6.8; ANSI C63.10, čl. 6.8 | ||
| 133 | Intentional radiators without radar detection | Measurement of dynamic frequency selection (DFS) Regulated area: 13 Radio parameters measured by ANSI methods |
ANSI C63.10, příl. K; KDB 905462 D02 čl. 7.8.3; ETSI EN 301 893, čl. 5.4.8 | ||
| 134 | Electrical and electronic equipment | Harmonics and interharmonics immunity test Regulated area: 14 Harmonics and interharmonics immunity |
EN 61000-4-13 | ||
| 135 | Automatic burner control systems for gaseous or liquid fuel appliances | Harmonics and interharmonics immunity test Regulated area: 14 Harmonics and interharmonics immunity |
EN 298, čl. 9.11; EN 13611, čl. 9.11 | ||
| 136 | Automatic electrical controls | Harmonics and interharmonics immunity test Regulated area: 14 Harmonics and interharmonics immunity |
EN 60730-2-5, čl.26, příl. H.26; EN 60730-1, čl.26, příl. H.26.4 | ||
| 137 | Household electrical appliances, gas appliances | Harmonics and interharmonics immunity test Regulated area: 14 Harmonics and interharmonics immunity |
EN 60335-1, čl. 19.11.4.7; EN 60335-2-102, čl. 19 | ||
| 138 | Unintentional radiators (ISED) | Emission measurement Regulated area: 15 Measurements according to ISED standards |
ICES-GEN; ICES-003 | ||
| 139 | Intentional radiators (ISED) | Measurement of radio parameters Regulated area: 15 Measurements according to ISED standards |
RSS-GEN; RSS-210, zařízení do 40 GHz; RSS-247 | ||
| 140 | Intentional radiators (ISED) | Measurement of human exposure to electromagnetic fields Regulated area: 15 Measurements according to ISED standards |
RSS-102, pouze FRL vyhodnocení | ||
Reference standards (222)
ANSI C63.10, příl. K
ANSI C63.10, čl. 11.10.2, 12.6
ANSI C63.10, čl. 11.11, 6.3, 6.5, 6.6, 12.7, 12.8
ANSI C63.10, čl. 11.6, 12.2
ANSI C63.10, čl. 6.10.4, 6.10.5, 6.10.6., 7.8.8, 11.11, 11.12, 11.13
ANSI C63.10, čl. 6.2
ANSI C63.10, čl. 6.3, 6.4, 6.5, 6.6
ANSI C63.10, čl. 6.7, 7.8.7, 11.12.2
ANSI C63.10, čl. 6.8
ANSI C63.10, čl. 6.9.2, 6.9.3, 11.8, 12.5
ANSI C63.10, čl. 7.8.2
ANSI C63.10, čl. 7.8.3
ANSI C63.10, čl. 7.8.4, 11.6
ANSI C63.10, čl. 7.8.5, 11.9, 12.4.2
ANSI C63.10:2013, čl. 11.10.2, 12.5
ANSI C63.10:2013, čl. 11.11, 6.3, 6.5, 6.6, 12.7
ANSI C63.10:2013, čl. 11.6, 12.2
ANSI C63.10:2013, čl. 6.10.4, 6.10.5, 6.10.6., 7.8.6, 7.8.8, 11.11, 11.12, 11.13
ANSI C63.10:2013, čl. 6.2
ANSI C63.10:2013, čl. 6.3, 6.4, 6.5, 6.6
ANSI C63.10:2013, čl. 6.7, 7.8.8, 11.12.2
ANSI C63.10:2013, čl. 6.8
ANSI C63.10:2013, čl. 6.9.2, 6.9.3, 11.8, 12.4
ANSI C63.10:2013, čl. 7.8.2
ANSI C63.10:2013, čl. 7.8.3
ANSI C63.10:2013, čl. 7.8.4, 11.6
ANSI C63.10:2013, čl. 7.8.5, 11.9,12.3.2, 12.6
ANSI C63.4:2014, čl. 7
ANSI C63.4:2014, čl. 8
EN 13611, čl. 9.10
EN 13611, čl. 9.11
EN 13611, čl. 9.2, 9.3
EN 13611, čl. 9.4
EN 13611, čl. 9.5
EN 13611, čl. 9.6
EN 13611, čl. 9.7
EN 13611, čl. 9.8
EN 13611, čl. 9.9
EN 13611:2007+A2:2011, čl. 8.10
EN 13611:2007+A2:2011, čl. 8.2, 8.3
EN 13611:2007+A2:2011, čl. 8.4
EN 13611:2007+A2:2011, čl. 8.5
EN 13611:2007+A2:2011, čl. 8.6
EN 13611:2007+A2:2011, čl. 8.7
EN 13611:2007+A2:2011, čl. 8.8
EN 13611:2007+A2:2011, čl. 8.9
EN 298, čl. 9.10
EN 298, čl. 9.11
EN 298, čl. 9.2, 9.3
EN 298, čl. 9.4
EN 298, čl. 9.5
EN 298, čl. 9.6
EN 298, čl. 9.7
EN 298, čl. 9.8
EN 298, čl. 9.9
EN 298:2012, čl. 8.10
EN 298:2012, čl. 8.2, 8.3
EN 298:2012, čl. 8.4
EN 298:2012, čl. 8.5
EN 298:2012, čl. 8.6
EN 298:2012, čl. 8.7
EN 298:2012, čl. 8.8
EN 298:2012, čl. 8.9
EN 50130-4, čl. 10
EN 50130-4, čl. 11
EN 50130-4, čl. 12
EN 50130-4, čl. 13
EN 50130-4, čl. 7, 8
EN 50130-4, čl. 9
EN 50270, tab. 1, položka 1.1
EN 50270, tab. 2, položka 2.1, tab. 3, položka 3.1, tab. 4, položka 4.1
EN 50270, tab. 2, položka 2.3, tab. 3, položka 3.2, tab. 4, položka 4.4
EN 50270, tab. 4, položka 4.2, 4.3
EN 50270, čl. 5, tab. 1, položka 1.2, 1.3, 1,4
EN 50270, čl. 5, tab. 1, položka 1.5
EN 50270, čl. 5, tab. 2, položka 2.2, tab. 3, položka 3.3, tab. 4, položka 4.5
EN 50270, čl. 6
EN 50270, čl. 6, mimo rozsah 0 kHz – 2 kHz
EN 55011, čl. 6.2.1, 6.3.1, 8.2
EN 55011, čl. 6.2.2, 6.3.2, 8.3, 8.4, 9
EN 55014-1, čl. 5.2
EN 55014-1, čl. 5.3
EN 55016-2-1
EN 55016-2-2
EN 55016-2-3
EN 55032, příl. A2, C3, C4
EN 55032, příl. A3, C3, C4
EN 60335-1, čl. 19.11.4.1
EN 60335-1, čl. 19.11.4.2
EN 60335-1, čl. 19.11.4.3
EN 60335-1, čl. 19.11.4.4
EN 60335-1, čl. 19.11.4.5
EN 60335-1, čl. 19.11.4.6 do 16 A, 19.11.4.8
EN 60335-1, čl. 19.11.4.7
EN 60335-2-102, čl. 19
EN 60730-1, čl. 23, příl. H23
EN 60730-1, čl. 23, příl. H23, mimo rozsah 0 kHz – 2 kHz
EN 60730-1, čl. 26, příl. H.26.11
EN 60730-1, čl. 26, příl. H.26.12.2
EN 60730-1, čl. 26, příl. H.26.12.3
EN 60730-1, čl. 26, příl. H.26.13
EN 60730-1, čl. 26, příl. H.26.14
EN 60730-1, čl. 26, příl. H.26.5
EN 60730-1, čl. 26, příl. H.26.8
EN 60730-1, čl. 26, příl. H.26.9
EN 60730-1, čl.26, příl. H.26.4
EN 60730-1:2011, čl. 23, příl. H23
EN 60730-1:2011, čl. 23, příl. H23, mimo rozsah 0 kHz – 2 kHz
EN 60730-1:2011, čl. 26, příl. H.26.11
EN 60730-1:2011, čl. 26, příl. H.26.12.2
EN 60730-1:2011, čl. 26, příl. H.26.12.3
EN 60730-1:2011, čl. 26, příl. H.26.13
EN 60730-1:2011, čl. 26, příl. H.26.14
EN 60730-1:2011, čl. 26, příl. H.26.5
EN 60730-1:2011, čl. 26, příl. H.26.8
EN 60730-1:2011, čl. 26, příl. H.26.9
EN 60730-2-5, příl. H.26.11
EN 60730-2-5, příl. H.26.12.2.1
EN 60730-2-5, příl. H.26.12.3
EN 60730-2-5, příl. H.26.13
EN 60730-2-5, příl. H.26.14
EN 60730-2-5, příl. H.26.5
EN 60730-2-5, příl. H.26.8
EN 60730-2-5, příl. H.26.9
EN 60730-2-5, čl. 23
EN 60730-2-5, čl.26, příl. H.26
EN 61000-4-11
EN 61000-4-12
EN 61000-4-13
EN 61000-4-2
EN 61000-4-28
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-9
EN 61000-6-1, tab. 1, položka 1.1
EN 61000-6-1, tab. 1, položka 1.4
EN 61000-6-1, tab. 1, položky 1.2, 1.3
EN 61000-6-1, tab. 2, položka 2.1, tab. 3, položka 3.1, tab. 4, položka 4.1
EN 61000-6-1, tab. 2, položka 2.2, tab. 3, položka 3.2, tab. 4, položka 4.4
EN 61000-6-1, tab. 2, položka 2.3, tab. 3, položka 3.3, tab. 4, položka 4.5
EN 61000-6-1, tab. 4, položka 4.2, 4.3
EN 61000-6-2, tab. 1, položka 1.1
EN 61000-6-2, tab. 1, položka 1.4
EN 61000-6-2, tab. 1, položky 1.2, 1.3
EN 61000-6-2, tab. 2, položka 2.1, tab. 3, položka 3.1, tab. 4, položka 4.1
EN 61000-6-2, tab. 2, položka 2.2, tab. 3, položka 3.2, tab. 4, položka 4.4
EN 61000-6-2, tab. 2, položka 2.3, tab. 3, položka 3.3, tab. 4, položka 4.5
EN 61000-6-2, tab. 4, položka 4.2, 4.3
EN 61000-6-3, čl. 11, tab. 3, položky 3.1, 3.3, 3.4
EN 61000-6-3, čl. 11, tab. 4, položka 4.3, 4.4, tab. 5, tab. 6
EN 61000-6-4, tab. 4, 5, A.1
EN 61000-6-4, čl. 9, tab. 3, položky 3.1, 3.3, 3.4
ETSI EN 300 220-1, čl. 5.10
ETSI EN 300 220-1, čl. 5.11
ETSI EN 300 220-1, čl. 5.12
ETSI EN 300 220-1, čl. 5.13
ETSI EN 300 220-1, čl. 5.14
ETSI EN 300 220-1, čl. 5.15
ETSI EN 300 220-1, čl. 5.16
ETSI EN 300 220-1, čl. 5.17
ETSI EN 300 220-1, čl. 5.18
ETSI EN 300 220-1, čl. 5.19
ETSI EN 300 220-1, čl. 5.2
ETSI EN 300 220-1, čl. 5.21
ETSI EN 300 220-1, čl. 5.22
ETSI EN 300 220-1, čl. 5.3
ETSI EN 300 220-1, čl. 5.4, 5.5
ETSI EN 300 220-1, čl. 5.6
ETSI EN 300 220-1, čl. 5.7
ETSI EN 300 220-1, čl. 5.8, 5.9
ETSI EN 300 220-1, čl. 5.9
ETSI EN 300 328 čl. 5.4.2
ETSI EN 300 328, čl. 5.3.2
ETSI EN 300 328, čl. 5.4.10
ETSI EN 300 328, čl. 5.4.11
ETSI EN 300 328, čl. 5.4.2
ETSI EN 300 328, čl. 5.4.3
ETSI EN 300 328, čl. 5.4.4
ETSI EN 300 328, čl. 5.4.5
ETSI EN 300 328, čl. 5.4.6
ETSI EN 300 328, čl. 5.4.7
ETSI EN 300 328, čl. 5.4.8, 5.4.9
ETSI EN 300 440, čl. 4.2.2
ETSI EN 300 440, čl. 4.2.3
ETSI EN 300 440, čl. 4.2.4
ETSI EN 300 440, čl. 4.2.5
ETSI EN 300 440, čl. 4.2.6
ETSI EN 300 440, čl. 4.3.3
ETSI EN 300 440, čl. 4.3.4
ETSI EN 300 440, čl. 4.3.5
ETSI EN 301 489-1, čl. 8.2
ETSI EN 301 489-1, čl. 8.3, 8.4, 8.5, 8.6, 8.7
ETSI EN 301 489-1, čl. 9.2
ETSI EN 301 489-1, čl. 9.3
ETSI EN 301 489-1, čl. 9.4
ETSI EN 301 489-1, čl. 9.5
ETSI EN 301 489-1, čl. 9.7
ETSI EN 301 489-1, čl. 9.8
ETSI EN 301 489-17, čl. 7.1
ETSI EN 301 489-17, čl. 7.2
ETSI EN 301 489-3, čl. 7.1
ETSI EN 301 489-3, čl. 7.2
ETSI EN 301 893, čl. 4.2.3
ETSI EN 301 893, čl. 5.4.10
ETSI EN 301 893, čl. 5.4.2
ETSI EN 301 893, čl. 5.4.3
ETSI EN 301 893, čl. 5.4.4
ETSI EN 301 893, čl. 5.4.5, 5.4.6
ETSI EN 301 893, čl. 5.4.7
ETSI EN 301 893, čl. 5.4.8
ETSI EN 301 893, čl. 5.4.9
ETSI TS 151 010-1, čl. 12.2, 12.4
ICES-003
ICES-GEN
KDB 905462 D02 čl. 7.8.3
RSS-102, pouze FRL vyhodnocení
RSS-210, zařízení do 40 GHz
RSS-247
RSS-GEN