🇨🇿 Vysoké učení technické v Brně PL

ČIA 1657 • Brno, Czech Republic • 26 methods

Electronics & EMC

Vysoké učení technické v Brně is a laboratory accredited by ČIA under number 1657 (Brno, Czech Republic). Its accreditation scope covers 26 test methods in the following areas: Electronics & EMC. Test objects include: Mechanical, electrotechnical and electronic components, products an…, Switchgear and controlgear, protection devices, switchboards, Breaking and protection devices, Low-voltage Switchgear and controlgear.

At a glance

  • Accreditation number: ČIA 1657
  • Methods in scope: 26
  • Types of test objects: 10
  • City: Brno, Czech Republic
  • Valid until: 03-09-2030
Accreditation number
1657
Accreditation body
ČIA
Address
Technická 3082/12, 616 00 Brno
City
Brno, Czech Republic
Division
Laboratorium Badawcze CVVOZE
Valid until
03-09-2030

What this laboratory tests (10)

Laboratory sections (2)

Laboratory locations

Certificate information

Certificate date
03.09.2025

Accreditation scope — test methods (26)

No. Test object Methodology / Parameters Technique Reference document
Location ZL1 – Environmental Testing Laboratory
1 Mechanical, electrotechnical and electronic components, products and parts Cold test
Regulated area: Tests
PI 1.01 (ČSN EN 60068-2-1 ed. 2)
2 Mechanical, electrotechnical and electronic components, products and parts Test: dry heat
Regulated area: Tests
PI 1.02 (ČSN EN 60068-2-2)
3 Mechanical, electrotechnical and electronic components, products and parts Test Nb: change of temperature with specified rate of change
Regulated area: Tests
PI 1.03 (ČSN EN IEC 60068-2-14 ed. 3, zkouška Nb)
4 Mechanical, electrotechnical and electronic components, products and parts Test: damp heat, cyclic
Regulated area: Tests
PI 1.04 (ČSN EN 60068-2-30 ed. 2)
5 Mechanical, electrotechnical and electronic components, products and parts Test: composite temperature/humidity cyclic test
Regulated area: Tests
PI 1.05 (ČSN EN IEC 60068-2-38 ed. 2)
6 Mechanical, electrotechnical and electronic components, products and parts Test: damp heat, steady state
Regulated area: Tests
PI 1.06 (ČSN EN 60068-2-78 ed. 2)
7 Mechanical, electrotechnical and electronic components, products and parts Test: vibration, sinusoidal
Regulated area: Tests
PI 1.07 (ČSN EN 60068-2-6 ed. 2; MIL-STD-810, metoda 514)
8 Mechanical, electrotechnical and electronic components, products and parts Test: vibration, time-history
Regulated area: Tests
PI 1.08 (ČSN EN 60068-2-57 ed. 2)
9 Mechanical, electrotechnical and electronic components, products and parts Test: vibration, sine-beat method
Regulated area: Tests
PI 1.09 (ČSN EN 60068-2-57 ed. 2)
10 Mechanical, electrotechnical and electronic components, products and parts Test: vibration, broadband random
Regulated area: Tests
PI 1.10 (ČSN EN 60068-2-64 ed. 2; ČSN EN 61373 ed. 2, mimo čl. 10; MIL-STD-810, metoda 514)
11 Mechanical, electrotechnical and electronic components, products and parts Test: vibration, mixed mode
Regulated area: Tests
PI 1.11 (ČSN EN 60068-2-80)
12 Mechanical, electrotechnical and electronic components, products and parts Combined vibration/shock test
Regulated area: Tests
PI 1.12 (ČSN EN 60068-2-53)
13 Mechanical, electrotechnical and electronic components, products and parts Shock/bump test
Regulated area: Tests
PI 1.13 (ČSN EN 60068-2-27 ed. 2; ČSN EN 61373 ed. 2, mimo čl. 8, 9; ČSN EN 60068-2-81; MIL-STD-810, metoda 516)
14 Mechanical, electrotechnical and electronic components, products and parts Seismic capability tests
Regulated area: Tests
PI 1.14 (ČSN EN IEC 60068-3-3 ed. 2)
15 Mechanical, electrotechnical and electronic components, products and parts Impact/bounce testing of loose cargo and transport packages
Regulated area: Tests
PI 1.15 (ČSN EN 60068-2-55, mimo metody A, B; ČSN EN ISO 13355)
16 Mechanical, electrotechnical and electronic components, products and parts Vertical impact test by dropping
Regulated area: Tests
PI 1.16 (ČSN EN 60068-2-31; ČSN EN 22248)
Location ZL3 – Switchgear Testing Laboratory
17 Protective, switching and safety devices Tests of short-circuit (residual) making and breaking capacities
Regulated area: Tests
PI 3.01 (ČSN EN 60898-1 ed. 2, čl. 9.12; ČSN EN 60898-2 ed. 3, čl. 9.12; ČSN EN IEC 60947-2 ed. 5, čl. 9.3.5.2, 9.3.6.3, 9.3.7.5, 9.3.8.2, 9.3.8.6, 9.3.8.7, 9.3.9.4, Příloha A, Příloha C.2, Příloha H.2, Příloha B - čl. B.8.1.2.2 (mimo B.8.1.2.2.3) a B.8.11, Příloha M - čl. M.8.14, Příloha P - čl. P.8.3.4, P.8.3.5, P.8.3.6; ČSN EN IEC 60947-3 ed. 4, čl. 9.3.6.3; ČSN EN 61008-1 ed. 3, čl. 9.11; ČSN EN 61009-1 ed. 3, čl. 9.12; ČSN EN 60269-1 ed. 3, čl. 8.5, 8.6, 8.7; ČSN EN 60269-4 ed. 3, čl. 8.5; ČSN EN 60269-6, čl. 8.5; ČSN EN 50123-1 ed. 2, čl. 7.6)
18 Power electrical equipment intended for the transmission, distribution and use of electrical energy Tests of short-term withstand and dynamic currents, conditional short-circuit currents
Regulated area: Tests
PI 3.01 (ČSN EN IEC 60947-2 ed. 5, čl. 9.3.7.3, 9.3.9.3, Příloha B.8.1.2.2.3; ČSN EN IEC 60947-3 ed. 4, čl. 9.3.6.2, 9.3.7.2.1; ČSN EN IEC 60947-4-1 ed. 4, čl. 9.3.4; ČSN EN IEC 60947-4-2 ed. 4, čl. 9.3.4; ČSN EN 60947-4-3 ed. 2, čl. 9.3.4; ČSN EN 61008-1 ed. 3, čl. 9.11; ČSN EN IEC 61439-1 ed. 3, čl. 10.11.5; ČSN EN IEC 61439-2 ed. 3, čl. 10.11.5; ČSN EN IEC 61439-3 ed. 2, čl. 10.11; ČSN EN IEC 61439-5 ed. 3, čl. 10.11; ČSN EN 61439-6, čl. 10.11; ČSN EN 61643-11 ed. 2, čl. 8.3.5.3, 8.3.8, 8.6.1.3, 8.6.4.3; ČSN EN 61643-31, čl. 7.4.4; ČSN EN 61869-2, čl. 7.2.201; ČSN EN 60076-5 ed. 2, čl. 4.1, 4.2; ČSN EN 50123-1 ed. 2, čl. 7.7; ČSN EN 50526-2, čl. 6.4, 6.5; ČSN EN 62271-1 ed. 2, čl. 7.6; ČSN EN IEC 62271-102 ed. 2, čl. 7.6; ČSN EN IEC 62271-103 ed. 2, čl. 7.6; ČSN EN IEC 62271-104 ed. 3, čl. 7.6; ČSN EN IEC 62271-200 ed. 3, čl. 7.6; ČSN EN 60077-2 ed. 2, čl. 9.3.4; ČSN EN IEC 60077-3 ed. 2, čl. 9.3.4; ČSN EN IEC 60077-4 ed. 2, čl. 9.3.4)
19 Low-voltage Switchgear and controlgear Tests of making and breaking capacities
Regulated area: Tests
PI 3.01 (ČSN EN IEC 60947-3 ed. 4, čl. 9.3.4.4; ČSN EN IEC 60947-4-1 ed. 4, čl. 9.3.3.5; ČSN EN IEC 60947-4-2 ed. 4, čl. 9.3.3.5; ČSN EN 60947-4-3 ed. 2, čl. 9.3.3.5)
20 Low-voltage switchgear and controlgear, protection devices Operational performance and overload tests
Regulated area: Tests
PI 3.02 (ČSN EN 60898-1 ed. 2, čl. 9.11; ČSN EN 60898-2 ed. 3, čl. 9.11; ČSN EN IEC 60947-2 ed. 5, čl. 9.3.4.4.4, 9.3.4.5, 9.3.5.3, 9.3.9.5, 9.3.10, Příloha B - čl. B.8.1.2.1, Příloha M - čl. M.8.11, Příloha P - čl. P.8.3.3, P.8.3.9; ČSN EN IEC 60947-3 ed. 4, čl. 9.3.5.2; ČSN EN IEC 60947-4-1 ed. 4, čl. 9.3.3.6; ČSN EN 61008-1 ed. 3, čl. 9.10; ČSN EN 61009-1 ed. 3, čl. 9.10; ČSN EN 50123-1 ed. 2, čl. 7.3.2)
21 Switchgear and controlgear No-Load operability tests
Regulated area: Tests
PI 3.02 (ČSN EN 60898-1 ed. 2, čl. 9.11; ČSN EN 60898-2 ed. 3, čl. 9.11; ČSN EN IEC 60947-2 ed. 5, čl. 9.3.4.4.3, 9.3.4.4.5, Příloha M - čl. M.8.11, Příloha P – čl. P.8.3.3; ČSN EN IEC 60947-3 ed. 4, čl. 9.3.5.2; ČSN EN 61008-1 ed. 3, čl. 9.10; ČSN EN 61009-1 ed. 3, čl. 9.10; ČSN EN 50123-1 ed. 2, čl. 7.3.3)
22 Switchgear and controlgear, protection devices, switchboards Dielectric withstand voltage tests
Regulated area: Tests
PI 3.03 (ČSN EN 50123-1 ed. 2, čl. 7.5.2; ČSN EN 50526-2, čl. 6.10; ČSN EN 60898-1 ed. 2, čl. 9.7.3, 9.7.4; ČSN EN IEC 60947-2 ed. 5, čl. 9.3.4.3, 9.3.4.6, 9.3.5.4, 9.3.6.4, 9.3.7.6, 9.3.8.4, 9.3.8.8, 9.3.9.6, Příloha C - čl. C.3, Příloha H - čl. H.3; ČSN EN IEC 60947-3 ed. 4, čl. 9.3.4.3, 9.3.5.3, 9.3.6.4, 9.3.7.4; ČSN EN IEC 60947-4-1 ed. 4, čl. 9.3.3.4; ČSN EN IEC 60947-4-2 ed. 4, čl. 9.3.3.4; ČSN EN 60947-4-3 ed. 2, čl. 9.3.3.4; ČSN EN 61008-1 ed. 3, čl. 9.7.3 a 9.7.4; ČSN EN 61009-1 ed. 3, čl. 9.7.3 a 9.7.4; ČSN EN 60269-1 ed. 3, čl. 8.2.2; ČSN EN IEC 61439-1 ed. 3, čl. 10.9.2; ČSN EN IEC 61439-5 ed. 3, čl. 10.9.2)
23 Switchgear and controlgear, switchboards Leakage current tests
Regulated area: Tests
PI 3.03 (ČSN EN IEC 60947-2 ed. 5, čl. 9.3.4.3, 9.3.4.6, 9.3.5.4, 9.3.6.4, 9.3.7.6, 9.3.8.4, 9.3.8.8, 9.3.9.6, Příloha C.3, Příloha H.3; ČSN EN IEC 60947-3 ed. 4, čl. 9.3.4.6, 9.3.5.4, 9.3.6.5, 9.3.7.5; ČSN EN IEC 60947-4-1 ed. 4, čl. 9.3.3.4; ČSN EN IEC 60947-4-2 ed. 4, čl. 9.3.3.4; ČSN EN 60947-4-3 ed. 2, čl. 9.3.3.4; ČSN EN 61008-1 ed. 3, čl. 9.7.7.3; ČSN EN 61009-1 ed. 3, čl. 9.7.7.3)
24 Switchgear and controlgear, protection devices, switchboards Insulation resistance tests
Regulated area: Tests
PI 3.03 (ČSN EN 60898-1 ed. 2, čl. 9.7.4; ČSN EN 61008-1 ed. 3, čl. 9.7.4; ČSN EN 61009-1 ed. 3, čl. 9.7.4; ČSN EN 60269-1 ed. 3, čl. 8.2.2, 8.5.8)
25 Switchgear and controlgear, switchboards, protection devices Temperature-rise tests
Regulated area: Tests
PI 3.04 (ČSN EN 60898-1 ed. 2, čl. 9.8; ČSN EN IEC 60947-2 ed. 5, čl. 9.3.4.7, 9.3.5.5, 9.3.7.4, 9.3.8.3, 9.3.9.7; ČSN EN IEC 60947-3 ed. 4, čl. 9.3.4.7, 9.3.5.5, 9.3.6.6, 9.3.7.6; ČSN EN IEC 60947-4-1 ed. 4, čl. 9.3.3.3; ČSN EN IEC 60947-4-2 ed. 4, čl. 9.3.3.3; ČSN EN 60947-4-3 ed. 2, čl. 9.3.3.3; ČSN EN 61008-1 ed. 3, čl. 9.8; ČSN EN 61009-1 ed. 3, čl. 9.8; ČSN EN 60269-1 ed. 3, čl. 8.3; ČSN EN 60269-4 ed. 3, čl. 8.3; ČSN EN 60269-6, čl. 8.3; ČSN EN IEC 61439-1 ed. 3, čl. 10.10.2; ČSN EN IEC 61439-2 ed. 3, čl. 10.10; ČSN EN IEC 61439-3 ed. 2, čl. 10.10; ČSN EN 61439-4, čl. 10.10; ČSN EN IEC 61439-5 ed. 3, čl. 10.10; ČSN EN 61439-6, čl. 10.10; ČSN EN 62271-1 ed. 2, čl. 7.5; ČSN EN IEC 62271-102 ed. 2, čl. 7.5; ČSN EN IEC 62271-103 ed. 2, čl. 7.5; ČSN EN IEC 62271-104 ed. 3, čl. 7.5; ČSN EN IEC 62271-200 ed. 3, čl. 7.5; ČSN EN 50123-1 ed. 2, čl. 7.4; ČSN EN 61869-1, čl. 7.2.2; ČSN EN 61869-2, čl. 7.2.2; ČSN EN 61869-3, čl. 7.2.2; ČSN EN 61869-4, čl. 7.2.2; ČSN EN 60077-1 ed. 2, čl. 9.3.2; ČSN EN 60077-2 ed. 2, čl. 9.3.3.4; ČSN EN IEC 60077-3 ed. 2, čl. 9.3.3.4; ČSN EN IEC 60077-4 ed. 2, čl. 9.3.3.4)
26 Breaking and protection devices Tests of tripping characteristic limits
Regulated area: Tests
PI 3.05 (ČSN EN 60898-1 ed. 2, čl. 9.10; ČSN EN 60898-2 ed. 3, čl. 9.10; ČSN EN IEC 60947-2 ed. 5, čl. 9.3.4.2, 9.3.4.8, 9.3.5.6, 9.3.6.2, 9.3.6.5, 9.3.7.2, 9.3.7.7, 9.3.8.5, 9.3.8.9, 9.3.9.2, 9.3.9.8, Příloha C - čl. C.4, Příloha H - čl. H.4; ČSN EN 61009-1 ed. 3, čl. 9.9.2; ČSN EN 60269-1 ed. 3, čl. 8.4; ČSN EN 60269-4 ed. 3, čl. 8.4; ČSN EN 60269-6, čl. 8.4)

Reference standards (78)

MIL-STD-810, metoda 514
MIL-STD-810, metoda 516
PI 1.01
PI 1.02
PI 1.03
PI 1.04
PI 1.05
PI 1.06
PI 1.07
PI 1.08
PI 1.09
PI 1.10
PI 1.11
PI 1.12
PI 1.13
PI 1.14
PI 1.15
PI 1.16
PI 3.01
PI 3.02
PI 3.03
PI 3.04
PI 3.05
ČSN EN 22248
ČSN EN 50123-1 ed. 2
ČSN EN 50526-2
ČSN EN 60068-2-1 ed. 2
ČSN EN 60068-2-2
ČSN EN 60068-2-27 ed. 2
ČSN EN 60068-2-30 ed. 2
ČSN EN 60068-2-31
ČSN EN 60068-2-53
ČSN EN 60068-2-55
ČSN EN 60068-2-57 ed. 2
ČSN EN 60068-2-6 ed. 2
ČSN EN 60068-2-64 ed. 2
ČSN EN 60068-2-78 ed. 2
ČSN EN 60068-2-80
ČSN EN 60068-2-81
ČSN EN 60076-5 ed. 2
ČSN EN 60077-1 ed. 2
ČSN EN 60077-2 ed. 2
ČSN EN 60269-1 ed. 3
ČSN EN 60269-4 ed. 3
ČSN EN 60269-6
ČSN EN 60898-1 ed. 2
ČSN EN 60898-2 ed. 3
ČSN EN 60947-4-3 ed. 2
ČSN EN 61008-1 ed. 3
ČSN EN 61009-1 ed. 3
ČSN EN 61373 ed. 2
ČSN EN 61439-4
ČSN EN 61439-6
ČSN EN 61643-11 ed. 2
ČSN EN 61643-31
ČSN EN 61869-1
ČSN EN 61869-2
ČSN EN 61869-3
ČSN EN 61869-4
ČSN EN 62271-1 ed. 2
ČSN EN IEC 60068-2-14 ed. 3
ČSN EN IEC 60068-2-38 ed. 2
ČSN EN IEC 60068-3-3 ed. 2
ČSN EN IEC 60077-3 ed. 2
ČSN EN IEC 60077-4 ed. 2
ČSN EN IEC 60947-2 ed. 5
ČSN EN IEC 60947-3 ed. 4
ČSN EN IEC 60947-4-1 ed. 4
ČSN EN IEC 60947-4-2 ed. 4
ČSN EN IEC 61439-1 ed. 3
ČSN EN IEC 61439-2 ed. 3
ČSN EN IEC 61439-3 ed. 2
ČSN EN IEC 61439-5 ed. 3
ČSN EN IEC 62271-102 ed. 2
ČSN EN IEC 62271-103 ed. 2
ČSN EN IEC 62271-104 ed. 3
ČSN EN IEC 62271-200 ed. 3
ČSN EN ISO 13355

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1657