🇨🇿 Nanolab, spol. s r.o. PL

ČIA 1625 • Brno, Czech Republic • 20 methods

Water & wastewater

Nanolab, spol. s r.o. is a laboratory accredited by ČIA under number 1625 (Brno, Czech Republic). Its accreditation scope covers 20 test methods in the following areas: Water & wastewater. Test objects include: Drinking, waste, surface and process waters, Drinking, waste, surface, ground and process waters, Waste waters, Drinking and process waters. Most frequently used techniques: gravimetric method, spectrophotometric method, acidimetric method.

At a glance

  • Accreditation number: ČIA 1625
  • Methods in scope: 20
  • Types of test objects: 10
  • Techniques used: 11
  • City: Brno, Czech Republic
  • Valid until: 20-01-2030
Accreditation number
1625
Accreditation body
ČIA
Address
Absolonova 719/30, Komín, 624 00 Brno
City
Brno, Czech Republic
Division
Laboratorium Chemiczne
Valid until
20-01-2030

What this laboratory tests (10)

Analytical techniques used (11)

Certificate information

Certificate date
20.01.2025

Accreditation scope — test methods (20)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Drinking, waste, surface, ground and process waters Determination of pH
Regulated area: Tests
potentiometric method SK-SOP-PH (ČSN ISO 10523)
2 Drinking, waste, surface, ground and process waters Determination of dissolved substances (RL 105)
Regulated area: Tests
gravimetric method SK-SOP-RL (ČSN 75 7346)
3 Drinking, waste, surface, ground and process waters Determination of suspended solids (NL 105)
Regulated area: Tests
gravimetric method SK-SOP-NL (ČSN EN 872)
4 Drinking, waste, surface, ground and process waters Determination of dissolved inorganic salts (RAS)
Regulated area: Tests
gravimetric method after filtration through a glass-fibre filter SK-SOP-RAS (ČSN 75 7347)
5 Waste, surface and process waters Determination of CODCr
Regulated area: Tests
titration method SK-SOP-CHSK (ČSN ISO 6060)
6 Waste waters Determination of EL and NEL (extractable and non-polar extractable substances)
Regulated area: Tests
IR spectrometry SK-SOP-EXL (ČSN 75 7505:1998; ČSN 75 7506)
7 Drinking, waste, surface and process waters Determination of chlorides (Cl-)
Regulated area: Tests
argentometric method SK-SOP-CL (ČSN ISO 9297)
8 Drinking, waste, surface and process waters Determination of nitrites (NO2-)
nitrite nitrogen (N-NO2-) calculated from measured values (calculated)
Regulated area: Tests
spectrophotometric method SK-SOP-NO2 (ČSN EN 26777)
9 Drinking, waste, surface and process waters Determination of ammonium ions (NH4+)
ammoniacal nitrogen (N-NH4+) calculated from measured values (calculated)
Regulated area: Tests
spectrophotometric method SK-SOP-NH4 (ČSN ISO 7150-1)
10 Drinking waters Determination of nitrates (NO3-)
Regulated area: Tests
UV spectrophotometry SK-SOP-NO3
11 Drinking, waste, surface and process waters Determination of phosphates (PO43-) and total phosphorus (Pc)
phosphates (PO43-) total phosphorus (Pc)
Regulated area: Tests
spectrophotometric method SK-SOP-TP (ČSN EN ISO 6878)
12 Drinking, surface and process waters Determination of electrical conductivity
Regulated area: Tests
SK-SOP-KON (ČSN EN 27888)
13 Drinking and process waters Determination of neutralising capacity (KNK4.5, KNK8.3, KNK5.4)
KNK4.5 (acid neutralising capacity to pH 4.5) KNK8.3 (acid neutralising capacity to pH 8.3) KNK5.4 (acid neutralising capacity to pH 5.4)
Regulated area: Tests
acidimetric method SK-SOP-NK (ČSN EN ISO 9963-1; ČSN EN ISO 9963-2)
14 Waste waters Determination of fats and oils
Regulated area: Tests
gravimetric method SK-SOP-TO (ČSN 757509)
15 Drinking and process waters Determination of the sum of calcium and magnesium (Ca + Mg)
Regulated area: Tests
complexometric method SK-SOP-TV (ČSN ISO 6059)
16 Drinking, waste and process waters Determination of sulphates SO42-
Regulated area: Tests
gravimetric method SK-SOP-SO4 (ČSN ISO 9280:1995)
17 Waste and surface waters Determination of total nitrogen (Nc) after oxidative digestion with peroxodisulphate
Regulated area: Tests
spectrophotometric method SK-SOP-TN (ČSN EN ISO 11905-1)
18 Waste, drinking waters Determination of hydrocarbon content C10-C40
Regulated area: Tests
GC/FID method SK-SOP-C10-C40 (ČSN EN ISO 9377-2)
19 Waste waters Manual sampling of waste waters
Regulated area: Sampling
SK-PI-VZV (ČSN ISO 5667-10)
20 Drinking waters Sampling of drinking waters
Regulated area: Sampling
SK-PI-VPV (ČSN ISO 5667-5; ČSN EN ISO 19458)

Reference standards (42)

SK-PI-VPV
SK-PI-VZV
SK-SOP-C10-C40
SK-SOP-CHSK
SK-SOP-CL
SK-SOP-EXL
SK-SOP-KON
SK-SOP-NH4
SK-SOP-NK
SK-SOP-NL
SK-SOP-NO2
SK-SOP-NO3
SK-SOP-PH
SK-SOP-RAS
SK-SOP-RL
SK-SOP-SO4
SK-SOP-TN
SK-SOP-TO
SK-SOP-TP
SK-SOP-TV
ČSN 75 7346
ČSN 75 7347
ČSN 75 7505:1998
ČSN 75 7506
ČSN 757509
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 11905-1
ČSN EN ISO 19458
ČSN EN ISO 6878
ČSN EN ISO 9377-2
ČSN EN ISO 9963-1
ČSN EN ISO 9963-2
ČSN ISO 10523
ČSN ISO 5667-10
ČSN ISO 5667-5
ČSN ISO 6059
ČSN ISO 6060
ČSN ISO 7150-1
ČSN ISO 9280:1995
ČSN ISO 9297

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1625