🇨🇿 SEKO BRNO, spol. s r.o. PL
Environment
SEKO BRNO, spol. s r.o. is a laboratory accredited by ČIA under number 1583 (Brno, Czech Republic). Its accreditation scope covers 14 test methods in the following areas: Environment. Test objects include: Emissions, Emissions, gas stream, Automated emission measuring systems. Most frequently used techniques: condensation-adsorption method, capacitive sensor, measurement of s…, flame ionisation method, gravimetric method.
At a glance
- Accreditation number: ČIA 1583
- Methods in scope: 14
- Types of test objects: 3
- Techniques used: 5
- City: Brno, Czech Republic
- Valid until: 06-02-2028
- Accreditation number
- 1583
- Accreditation body
- ČIA
- Address
- Křižíkova 2697/70, Královo Pole, 612 00 Brno
- City
- Brno, Czech Republic
- Division
- Pomiary Emisji Przemysłowych
- Valid until
- 06-02-2028
What this laboratory tests (3)
- Emissions — 11 methods
- Emissions, gas stream — 2 methods
- Automated emission measuring systems — 1 method
Analytical techniques used (5)
- condensation-adsorption method, capacitive sensor, measurement of saturated vapour temperature — 1 method
- flame ionisation method — 1 method
- gravimetric method — 1 method
- NDIR method — 1 method
- paramagnetic method — 1 method
Certificate information
- Certificate date
- 06.02.2023
Accreditation scope — test methods (14)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Emissions, gas stream | Determination of flow velocity and volume flow rate Regulated area: Tests |
SOP 01 (ČSN ISO 10780) | ||
| 2 | Emissions | Determination of oxygen concentration by paramagnetic method Regulated area: Tests |
paramagnetic method | SOP 03 (ČSN EN 14789) | |
| 3 | Emissions | Determination of mass concentration of gaseous pollutants by NDIR method (NO and NO2, SO2, CO) NO and NO2 (nitrogen oxides) Sulphur dioxide (SO2) Carbon monoxide (CO) Regulated area: Tests |
NDIR method | SOP 04 (ČSN ISO 10849; ČSN ISO 7935; ČSN EN 15058) | |
| 4 | Emissions | Determination of mass concentration of organic substances expressed as total organic carbon by flame ionisation method (TOC) Regulated area: Tests |
flame ionisation method | SOP 05 (ČSN EN 12619) | |
| 5 | Emissions | Determination of mass concentration of volatile organic compounds (VOC) after trapping on solid sorbent by calculation from measured values Regulated area: Tests |
SOP 06 - část B (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1) | ||
| 6 | Emissions | Determination of mass concentration of particulate pollutants gravimetrically Regulated area: Tests |
gravimetric method | SOP 07 - část B (ČSN ISO 9096:1998; ČSN EN 13284-1) | |
| 7 | Emissions | Determination of mass concentration of metals by calculation from measured values arsenic cadmium chromium cobalt copper manganese nickel lead antimony thallium vanadium tin selenium zinc mercury Regulated area: Tests |
SOP 08 - část B (ČSN EN 14385; ČSN EN 13211) | ||
| 8 | Emissions | Determination of mass concentration of gases and vapours by absorption into liquid by calculation from measured values (HCl) Hydrogen chloride (HCl) Regulated area: Tests |
SOP 09 - část B (ČSN EN 1911) | ||
| 9 | Automated emission measuring systems | Quality assurance of automated measuring systems Regulated area: Tests |
SOP 10 (ČSN EN 14181 čl. 6; QAL2, čl. 8 AST) | ||
| 10 | Emissions, gas stream | Determination of water vapour content in the duct Regulated area: Tests |
condensation-adsorption method, capacitive sensor, measurement of saturated vapour temperature | SOP 02 (ČSN EN 14790) | |
| 11 | Emissions | Sampling of volatile organic compounds (VOC) by trapping on solid sorbent Regulated area: Sampling |
SOP 06 - část A (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1) | ||
| 12 | Emissions | Isokinetic sampling of particulate pollutants with automatic or manual isokinetic control Regulated area: Sampling |
SOP 07 - část A (ČSN ISO 9096:1998; ČSN EN 13284-1) | ||
| 13 | Emissions | Isokinetic sampling for determination of heavy metals with automatic or manual isokinetic control Regulated area: Sampling |
SOP 08 - část A (ČSN EN 14385; ČSN EN 13211) | ||
| 14 | Emissions | Sampling of gases and vapours by absorption into liquid (HCl) Regulated area: Sampling |
SOP 09 - část B (ČSN EN 1911) | ||
Reference standards (28)
SOP 01
SOP 02
SOP 03
SOP 04
SOP 05
SOP 06 - část A
SOP 06 - část B
SOP 07 - část A
SOP 07 - část B
SOP 08 - část A
SOP 08 - část B
SOP 09 - část B
SOP 10
ČSN EN 12619
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 14181 čl. 6; QAL2, čl. 8 AST
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 15058
ČSN EN 1911
ČSN EN ISO 16017-1
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 7935
ČSN ISO 9096:1998
ČSN P CEN/TS 13649