🇨🇿 ET EKOTERM s.r.o. PL

ČIA 1558 • Jihlava, Czech Republic • 15 methods

Environment

ET EKOTERM s.r.o. is a laboratory accredited by ČIA under number 1558 (Jihlava, Czech Republic). Its accreditation scope covers 15 test methods in the following areas: Environment. Test objects include: Emissions. Most frequently used techniques: chemiluminescence method, condensation-absorption method, condensation method, capacitive sensor, electrochemical cells.

At a glance

  • Accreditation number: ČIA 1558
  • Methods in scope: 15
  • Types of test objects: 1
  • Techniques used: 7
  • City: Jihlava, Czech Republic
  • Valid until: 13-07-2027
Accreditation number
1558
Accreditation body
ČIA
Address
Znojemská 2716/78, 586 01 Jihlava
City
Jihlava, Czech Republic
Division
Dział Pomiarów Emisji
Valid until
13-07-2027

What this laboratory tests (1)

Analytical techniques used (7)

Certificate information

Certificate date
13.07.2022

Accreditation scope — test methods (15)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Emissions Determination of flow velocity and volume flow rate
Regulated area: Tests
SOP 01, část A (ČSN ISO 10780, ČSN EN ISO 16911-1)
2 Emissions Determination of gas moisture
Regulated area: Tests
condensation-absorption method, condensation method, capacitive sensor SOP 01, část B (ČSN EN 14790)
3 Emissions Determination of mass concentration of gaseous pollutants (SO2, CO) by automated analysers
Sulphur dioxide (SO2) Carbon monoxide (CO)
Regulated area: Tests
non-dispersive infrared spectrometry SOP 02, část A (ČSN ISO 7935, ČSN EN 15058)
4 Emissions Determination of mass concentration of gaseous pollutants (NOx) by automated analysers
Nitrogen oxides (NOx)
Regulated area: Tests
chemiluminescence method SOP 02, část B (ČSN EN 14792)
5 Emissions Determination of volume concentration of oxygen (O2) by automated analyser
Regulated area: Tests
paramagnetic method SOP 07 (ČSN EN 14789)
6 Emissions Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) by automated analysers (FID)
Regulated area: Tests
FID (flame ionisation detection) SOP 03 (ČSN EN 12619)
7 Emissions Determination of mass concentration of particulate pollutants
Regulated area: Tests
gravimetry SOP 04, část B (ČSN EN 13284-1)
8 Emissions Determination of mass concentration of volatile organic compounds (VOC) – by calculation from measured values
Regulated area: Tests
SOP 08 (ČSN P CEN/TS 13649)
9 Emissions Determination of volume concentration of oxygen (O2) by automated analyser with electrochemical cells
Regulated area: Tests
electrochemical cells SOP 10 (manuál firmy MRU Messgeräte für Rauchgase und Umweltschutz GmbH)
10 Emissions Determination of mass concentration of metals by calculation from measured values (As, Cd, Be, Cr, Co, Ni, Se, Sb, Sn, Mn, Cu, Pb, V, Zn)
Arsenic (As) Cadmium (Cd) Beryllium (Be) Chromium (Cr) Cobalt (Co) Nickel (Ni) Selenium (Se) Antimony (Sb) Tin (Sn) Manganese (Mn) Copper (Cu) Lead (Pb) Vanadium (V) Zinc (Zn)
Regulated area: Tests
SOP 13, část B (ČSN EN 14385, US EPA 29)
11 Emissions Determination of mass concentration of gases and vapours – by calculation from measured values (inorganic chlorine compounds and HCl) (inorganic fluorine compounds and HF) (ammonia)
inorganic chlorine compounds and HCl inorganic fluorine compounds and HF Ammonia
Regulated area: Tests
SOP 12 ČSN EN 1911, ČSN P CEN/TS 17340 ČSN EN ISO 21877)
12 Emissions Sampling of volatile organic compounds (VOC) by trapping on solid sorbent
Regulated area: Sampling
SOP 05 (ČSN P CEN/TS 13649)
13 Emissions Sampling of particulate pollutants (isokinetic sampling with manual isokinetic control)
Regulated area: Sampling
SOP 04, část A (ČSN EN 13284-1)
14 Emissions Sampling for determination of heavy metals (As, Cd, Be, Cr, Co, Ni, Se, Sb, Sn, Mn, Cu, Pb, V, Zn) – isokinetic sampling with manual isokinetic control and absorption into liquid
Regulated area: Sampling
SOP 13, část A (ČSN EN 14385, US EPA 29)
15 Emissions Sampling of gases and vapours by absorption into liquid (inorganic chlorine compounds and HCl) (inorganic fluorine compounds and HF) (ammonia)
Regulated area: Sampling
SOP 11 (ČSN EN 1911, ČSN P CEN/TS 17340, ČSN EN ISO 21877

Reference standards (31)

SOP 01, část A
SOP 01, část B
SOP 02, část A
SOP 02, část B
SOP 03
SOP 04, část A
SOP 04, část B
SOP 05
SOP 07
SOP 08
SOP 10
SOP 11
SOP 12
SOP 13, část A
SOP 13, část B
US EPA 29
manuál firmy MRU Messgeräte für Rauchgase und Umweltschutz GmbH
ČSN EN 12619
ČSN EN 13284-1
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 14792
ČSN EN 15058
ČSN EN 1911
ČSN EN ISO 16911-1
ČSN EN ISO 21877
ČSN ISO 10780
ČSN ISO 7935
ČSN P CEN/TS 13649
ČSN P CEN/TS 17340

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1558