🇨🇿 EKOPOR Kladno, spol. s r.o. PL

ČIA 1556 • Řevničov, Czech Republic • 8 methods

Environment

EKOPOR Kladno, spol. s r.o. is a laboratory accredited by ČIA under number 1556 (Řevničov, Czech Republic). Its accreditation scope covers 8 test methods in the following areas: Environment. Test objects include: Emissions. Most frequently used techniques: chemiluminescence, condensation method and capacitive polymer sensor, flame ionisation detector (FID).

At a glance

  • Accreditation number: ČIA 1556
  • Methods in scope: 8
  • Types of test objects: 1
  • Techniques used: 7
  • City: Řevničov, Czech Republic
  • Valid until: 21-04-2027
Accreditation number
1556
Accreditation body
ČIA
Address
Nová Draha 505, 270 54 Řevničov
City
Řevničov, Czech Republic
Division
Laboratorium Badawcze EKOPOR
Valid until
21-04-2027

What this laboratory tests (1)

Analytical techniques used (7)

Certificate information

Certificate date
21.04.2022

Accreditation scope — test methods (8)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Emissions Determination of mass concentration of gaseous pollutants (SO2, CO, CO2) by automated analyser
Sulphur dioxide (SO2) Carbon monoxide (CO) Carbon dioxide (CO2)
Regulated area: Tests
non-dispersive infrared absorption spectrometry SOP 1 (ČSN EN 15259, ČSN 83 4711-7, ČSN ISO 7935, ČSN EN 15058)
2 Emissions Determination of mass concentration of gaseous pollutants (NOX) by automated analyser
Nitrogen oxides (NOX)
Regulated area: Tests
chemiluminescence SOP 2 (ČSN EN 15259, ČSN EN 14792)
3 Emissions Determination of volume concentration of oxygen (O2) by automated analyser
Regulated area: Tests
paramagnetic method SOP 3 (ČSN EN 15259, ČSN EN 14789)
4 Emissions Determination of mass concentration of particulate pollutants
Regulated area: Tests
gravimetry SOP 4 a (ČSN EN 15259, ČSN EN 13284-1)
5 Emissions Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) by automated analyser
Regulated area: Tests
flame ionisation detector (FID) SOP 5 (ČSN EN 15259, ČSN EN 12619)
6 Emissions Determination of flow velocity, volume flow rate, temperature and pressure of gas in the duct.
Regulated area: Tests
SOP 6 a (ČSN EN 15259, ČSN ISO 10780)
7 Emissions Determination of gas moisture
Regulated area: Tests
condensation method and capacitive polymer sensor SOP 6 b (ČSN EN 15259, ČSN EN 14790)
8 Emissions Sampling of particulate pollutants
Regulated area: Sampling
isokinetic sampling with automatic isokinetic control SOP 4 b (ČSN EN 15259, ČSN EN 13284-1)

Reference standards (18)

SOP 1
SOP 2
SOP 3
SOP 4 a
SOP 4 b
SOP 5
SOP 6 a
SOP 6 b
ČSN 83 4711-7
ČSN EN 12619
ČSN EN 13284-1
ČSN EN 14789
ČSN EN 14790
ČSN EN 14792
ČSN EN 15058
ČSN EN 15259
ČSN ISO 10780
ČSN ISO 7935