🇨🇿 Ing. Jiří Kubík PL
Environment
Ing. Jiří Kubík is a laboratory accredited by ČIA under number 1555 (Plzeň - Lobzy, Czech Republic). Its accreditation scope covers 16 test methods in the following areas: Environment. Test objects include: Emissions. Most frequently used techniques: condensation method and capacitive sensor, FID (flame ionisation detector), gravimetric method.
At a glance
- Accreditation number: ČIA 1555
- Methods in scope: 16
- Types of test objects: 1
- Techniques used: 7
- City: Plzeň - Lobzy, Czech Republic
- Valid until: 28-03-2027
- Accreditation number
- 1555
- Accreditation body
- ČIA
- Address
- Pod Vrchem 51, 312 80 Plzeň - Lobzy
- City
- Plzeň - Lobzy, Czech Republic
- Division
- Laboratorium Badawcze Ing. Jiří Kubík – Pomiary Emisji
- Valid until
- 28-03-2027
What this laboratory tests (1)
- Emissions — 16 methods
Analytical techniques used (7)
- condensation method and capacitive sensor — 1 method
- FID (flame ionisation detector) — 1 method
- gravimetric method — 1 method
- NDIR (non-dispersive infrared spectrometry) — 1 method
- paramagnetic method — 1 method
- spectrophotometric method — 1 method
- titration with thorin indicator — 1 method
Certificate information
- Certificate date
- 28.03.2022
Accreditation scope — test methods (16)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Emissions | Determination of flow velocity and volume flow rate Regulated area: Tests |
SOP 01 část A (ČSN ISO 10780) | ||
| 2 | Emissions | Determination of moisture Regulated area: Tests |
condensation method and capacitive sensor | SOP 01 část B (ČSN EN 14790) | |
| 3 | Emissions | Determination of mass concentration of gaseous pollutants by automated NDIR analysers (sulphur dioxide, nitrogen oxides, carbon monoxide) sulphur dioxide nitrogen oxides carbon monoxide Regulated area: Tests |
NDIR (non-dispersive infrared spectrometry) | SOP 02 (ČSN ISO 10849, ČSN EN 15058, ČSN ISO 7935, ISO 10396) | |
| 4 | Emissions | Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) by automated analysers (FID) Regulated area: Tests |
FID (flame ionisation detector) | SOP 04 (ČSN EN 12619) | |
| 5 | Emissions | Determination of mass concentration of particulate pollutants gravimetrically Regulated area: Tests |
gravimetric method | SOP 05 část B (ČSN EN 13284-1) | |
| 6 | Emissions | Determination of mass concentration of inorganic chlorine compounds spectrophotometrically Regulated area: Tests |
spectrophotometric method | SOP 03 (ČSN EN 1911) | |
| 7 | Emissions | Determination of mass concentration of sulphur dioxide by titration with thorin indicator Regulated area: Tests |
titration with thorin indicator | SOP 06 (ČSN EN 14791) | |
| 8 | Emissions | Determination of oxygen concentration by paramagnetic method Regulated area: Tests |
paramagnetic method | SOP 07 (ČSN EN 14789) | |
| 9 | Emissions | Determination of mass concentration of volatile organic compounds (VOC) by calculation from measured values Regulated area: Tests |
SOP 09 část B (ČSN P CEN/TS 13649) | ||
| 10 | Emissions | Determination of mass concentration of metals by calculation from measured values (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Hg, Zn) Arsenic (As) Cadmium (Cd) Chromium (Cr) Cobalt (Co) Copper (Cu) Manganese (Mn) Nickel (Ni) Lead (Pb) Antimony (Sb) Thallium (Tl) Vanadium (V) Mercury (Hg) Zinc (Zn) Regulated area: Tests |
SOP 10 část B (ČSN EN 14385 ČSN EN 13284-1 ČSN EN 13211) | ||
| 11 | Emissions | Determination of mass concentration of persistent organic pollutants by calculation from measured values (PCDD/PCDF, PCB, PAH) PCDD/PCDF (polychlorinated dibenzo-p-dioxins and dibenzofurans) PCB (polychlorinated biphenyls) PAH (polyaromatic hydrocarbons) Regulated area: Tests |
SOP 11 část B (ČSN EN 1948-1, ČSN EN 1948-4+A1) | ||
| 12 | Emissions | Sampling of volatile organic compounds (VOC) by trapping on solid sorbent Regulated area: Sampling |
SOP 09 část A (ČSN P CEN/TS 13649) | ||
| 13 | Emissions | Sampling for determination of heavy metals (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Hg, Zn) – isokinetic sampling with manual isokinetic control and absorption into liquid Regulated area: Sampling |
SOP 10 část A (ČSN EN 14385, ČSN EN 13211) | ||
| 14 | Emissions | Sampling for determination of persistent organic pollutants (PCDD/PCDF, PCB, PAH) – isokinetic sampling with manual isokinetic control, filter-condenser method Regulated area: Sampling |
SOP 11 část A (ČSN EN 1948-1, ČSN EN 1948-4+A1) | ||
| 15 | Emissions | Sampling of gases and vapours by absorption into liquid (inorganic chlorine compounds and sulphur dioxide) Regulated area: Sampling |
SOP 12 (ČSN EN 1911, ČSN EN 14791) | ||
| 16 | Emissions | Sampling of particulate pollutants (isokinetic sampling with manual isokinetic control) Regulated area: Sampling |
SOP 05 část A (ČSN EN 13284-1) | ||
Reference standards (32)
ISO 10396
SOP 01 část A
SOP 01 část B
SOP 02
SOP 03
SOP 04
SOP 05 část A
SOP 05 část B
SOP 06
SOP 07
SOP 09 část A
SOP 09 část B
SOP 10 část A
SOP 10 část B
SOP 11 část A
SOP 11 část B
SOP 12
ČSN EN 12619
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 14791
ČSN EN 15058
ČSN EN 1911
ČSN EN 1948-1
ČSN EN 1948-4+A1
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 7935
ČSN P CEN/TS 13649