🇨🇿 ČEZ, a. s. PL

ČIA 1545 • Kadaň, Czech Republic • 33 methods

Water & wastewaterPetrochemistry & fuels

ČEZ, a. s. is a laboratory accredited by ČIA under number 1545 (Kadaň, Czech Republic). Its accreditation scope covers 33 test methods in the following areas: Water & wastewater, Petrochemistry & fuels. Test objects include: Waste and surface waters, Brown coal, Surface water, Waste water.

At a glance

  • Accreditation number: ČIA 1545
  • Methods in scope: 33
  • Types of test objects: 5
  • City: Kadaň, Czech Republic
  • Valid until: 15-12-2026
Accreditation number
1545
Accreditation body
ČIA
Address
Tušimice č.p. 9, 432 01 Kadaň
City
Kadaň, Czech Republic
Division
Elektrownie Tušimice i Prunéřov – Laboratorium Badawcze
Valid until
15-12-2026

What this laboratory tests (5)

Laboratory sections (2)

Laboratory locations

Certificate information

Certificate date
20.11.2025

Accreditation scope — test methods (33)

No. Test object Methodology / Parameters Technique Reference document
ETU Chemical Laboratories
1 Brown coal Determination of residual and analytical moisture content gravimetrically and total moisture by calculation from measured values
Regulated area: Tests
PPOJ-S-01 (ČSN 44 1377)
2 Brown coal Determination of gross calorific value calorimetrically and net calorific value by calculation from measured values
Regulated area: Tests
PPOJ-S-03 (ČSN ISO 1928; ČSN 44 1310)
3 Brown coal Determination of total sulphur content by IR spectrometry
Regulated area: Tests
PPOJ-S-04 (ČSN ISO 19579; ČSN 44 1310)
4 Brown coal Determination of coarse (free) moisture content gravimetrically
Regulated area: Tests
PPOJ-S-06 (ČSN 44 1377)
5 Brown coal, energy by-products (VEP) Determination of analytical moisture, ash and unburnt carbon content thermogravimetrically with a TGA analyser
Regulated area: Tests
PPOJ-S-08 (ČSN 44 1377; ČSN ISO 1171; ČSN 44 1375; ČSN 44 1310)
6 Waste and surface waters Determination of temperature
Regulated area: Tests
PPOJ-S-19 (ČSN 75 7342)
7 Waste and surface waters Determination of pH potentiometrically
Regulated area: Tests
PPOJ-S-21 (ČSN ISO 10523)
8 Waste and surface waters Determination of electrical conductivity
Regulated area: Tests
PPOJ-S-20 (ČSN EN 27888)
9 Waste and surface waters Determination of total phosphorus spectrophotometrically
Regulated area: Tests
PPOJ-S-11 (ČSN EN ISO 6878)
10 Waste and surface waters Determination of biochemical oxygen demand (BOD5) with a membrane probe electrochemically
Regulated area: Tests
PPOJ-S-12 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN EN ISO 5814)
11 Waste and surface waters Determination of nitrite nitrogen (N-NO2) spectrophotometrically and nitrites (NO2-) by calculation from measured values
Regulated area: Tests
PPOJ-S-13 (ČSN EN 26777)
12 Waste and surface waters Determination of chemical oxygen demand (CODCr) with dichromate spectrophotometrically
Regulated area: Tests
PPOJ-S-14 (ČSN ISO 15705; TNV 75 7520:2002)
13 Waste and surface waters Determination of ammonium nitrogen (N-NH4) spectrophotometrically and ammonium ions (NH4+) by calculation from measured values
Regulated area: Tests
PPOJ-S-15 (ČSN ISO 7150-1)
14 Waste and surface waters Determination of suspended solids (NL) gravimetrically
Regulated area: Tests
PPOJ-S-16 (ČSN EN 872)
15 Waste and surface waters Determination of nitrate nitrogen (N-NO3) spectrophotometrically, nitrates (NO3-) and (inorganic N) by calculation from measured values
Regulated area: Tests
PPOJ-S-17 (ČSN ISO 7890-3)
16 Waste and surface waters Determination of dissolved substances (RL) and dissolved inorganic salts (RAS) gravimetrically
Regulated area: Tests
PPOJ-S-18 (ČSN 75 7346; ČSN 75 7347)
17 Waste water Sampling of waste waters manually and with an automatic sampler
Regulated area: Sampling
PPOJ-S-51 část A (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN ISO 5667-10)
18 Surface water Sampling of surface waters manually
Regulated area: Sampling
PPOJ-S-51 část B (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN ISO 5667-7)
EPR Chemical Laboratories
19 Brown coal Determination of coarse (free) moisture content gravimetrically
Regulated area: Tests
PPOJ-S-06 (ČSN 44 1377)
20 Waste and surface waters Determination of temperature
Regulated area: Tests
PPOJ-S-19 (ČSN 75 7342)
21 Waste and surface waters Determination of pH potentiometrically
Regulated area: Tests
PPOJ-S-21 (ČSN ISO 10523)
22 Waste and surface waters Determination of electrical conductivity
Regulated area: Tests
PPOJ-S-20 (ČSN EN 27888)
23 Waste and surface waters Determination of total phosphorus spectrophotometrically
Regulated area: Tests
PPOJ-S-11 (ČSN EN ISO 6878)
24 Waste and surface waters Determination of biochemical oxygen demand (BOD5) with a membrane probe electrochemically
Regulated area: Tests
PPOJ-S-12 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN EN ISO 5814)
25 Waste and surface waters Determination of nitrite nitrogen (N-NO2) spectrophotometrically and nitrites (NO2-) by calculation from measured values
Regulated area: Tests
PPOJ-S-13 (ČSN EN 26777)
26 Waste and surface waters Determination of chemical oxygen demand (CODCr) with dichromate spectrophotometrically
Regulated area: Tests
PPOJ-S-14 (ČSN ISO 15705; TNV 75 7520:2002)
27 Waste and surface waters Determination of ammonium nitrogen (N-NH4) spectrophotometrically and ammonium ions (NH4+) by calculation from measured values
Regulated area: Tests
PPOJ-S-15 (ČSN ISO 7150-1)
28 Waste and surface waters Determination of suspended solids (NL) gravimetrically
Regulated area: Tests
PPOJ-S-16 (ČSN EN 872)
29 Waste and surface waters Determination of nitrate nitrogen (N-NO3) spectrophotometrically, nitrates (NO3-) and (inorganic N) by calculation from measured values
Regulated area: Tests
PPOJ-S-17 (ČSN ISO 7890-3)
30 Waste and surface waters Determination of dissolved substances (RL) and dissolved inorganic salts (RAS) gravimetrically
Regulated area: Tests
PPOJ-S-18 (ČSN 75 7346; ČSN 75 7347)
31 Waste and surface waters Determination of the sum of hydrocarbons C10 – C40 by gas chromatography with flame ionization detector (GC-FID)
Regulated area: Tests
PPOJ-S-23 (ČSN EN ISO 9377-2)
32 Waste water Sampling of waste waters manually and with an automatic sampler
Regulated area: Sampling
PPOJ-S-51 část A (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN ISO 5667-10)
33 Surface water Sampling of surface waters manually
Regulated area: Sampling
PPOJ-S-51 část B (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN ISO 5667-7)

Reference standards (48)

PPOJ-S-01
PPOJ-S-03
PPOJ-S-04
PPOJ-S-06
PPOJ-S-08
PPOJ-S-11
PPOJ-S-12
PPOJ-S-13
PPOJ-S-14
PPOJ-S-15
PPOJ-S-16
PPOJ-S-17
PPOJ-S-18
PPOJ-S-19
PPOJ-S-20
PPOJ-S-21
PPOJ-S-23
PPOJ-S-51 část A
PPOJ-S-51 část B
TNV 75 7520:2002
ČSN 44 1310
ČSN 44 1375
ČSN 44 1377
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN EN 1899-2
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 5667-1
ČSN EN ISO 5667-14
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5814
ČSN EN ISO 5815-1
ČSN EN ISO 6878
ČSN EN ISO 9377-2
ČSN ISO 10523
ČSN ISO 1171
ČSN ISO 15705
ČSN ISO 1928
ČSN ISO 19579
ČSN ISO 5667-10
ČSN ISO 5667-4
ČSN ISO 5667-7
ČSN ISO 7150-1
ČSN ISO 7890-3

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1545