🇨🇿 ETD TRANSFORMÁTORY a.s. PL
Electronics & EMC
ETD TRANSFORMÁTORY a.s. is a laboratory accredited by ČIA under number 1526 (Plzeň, Czech Republic). Its accreditation scope covers 46 test methods in the following areas: Electronics & EMC. Test objects include: Electrical equipment of driving vehicles, Fuses, Rolling stock electrical equipment, Semiconductor converters.
At a glance
- Accreditation number: ČIA 1526
- Methods in scope: 46
- Types of test objects: 22
- City: Plzeň, Czech Republic
- Valid until: 09-06-2028
- Accreditation number
- 1526
- Accreditation body
- ČIA
- Address
- Zborovská 54/22, Doudlevce, 301 00 Plzeň
- City
- Plzeň, Czech Republic
- Division
- Laboratorium Badań Elektrotechnicznych
- Valid until
- 09-06-2028
What this laboratory tests (22)
- Electrical equipment of driving vehicles — 4 methods
- Fuses — 4 methods
- Rolling stock electrical equipment — 4 methods
- Semiconductor converters — 4 methods
- Switchboards — 4 methods
- Switchgear and controlgear — 4 methods
- Electrical machines and instruments — 3 methods
- Electrical machines, instruments — 3 methods
- Transformers and their parts — 3 methods
- Electrical equipment enclosures — 1 method
- Electrical equipment of railway vehicles - Electrical components — 1 method
- Equipment with flowing or pressure liquid — 1 method
- Fans — 1 method
- Fixed traction equipment - Overhead contact lines for electric traction — 1 method
- High voltage switchgear and controlgear — 1 method
- and 7 more
Certificate information
- Certificate date
- 05.12.2024
Accreditation scope — test methods (46)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Electrical equipment enclosures | Verification of degree of protection (IP code) up to the degree IP 4X Regulated area: Degree of protection (IP code) |
SOP_EZ/1; ČSN EN 60529 | ||
| 2 | Switchboards and their functional parts | Verification of degree of protection (IP code) up to the degree IP 4X Regulated area: Degree of protection (IP code) |
SOP_EZ/1; ČSN EN IEC 61439-1 ed.3, čl. 10.3; ČSN EN IEC 61439-2 ed.3, čl. 10.3; ČSN EN 50123-6 ed.2, čl. 8.3.6 | ||
| 3 | High voltage switchgear and controlgear | Verification of degree of protection (IP code) up to the degree IP 4X Regulated area: Degree of protection (IP code) |
SOP_EZ/1; ČSN EN 62271-1 ed.2, čl. 7.7.1; ČSN EN IEC 62271-100 ed.3, čl. 7.7.1; ČSN EN IEC 62271-102 ed.2, čl. 7.7; ČSN EN 62271-103 ed.2, čl. 7.7; ČSN EN IEC 62271-200 ed.3, čl. 7.7.1; ČSN EN 62271-202 ed.3, čl. 7.7 | ||
| 4 | Electrical machines and instruments | Measurement of temperature-rise, temperature and losses Regulated area: Temperature rise |
SOP_EZ/2; POM_EZ/1; POM_EZ/2 | ||
| 5 | Electrical equipment of driving vehicles | Measurement of temperature-rise, temperature and losses Regulated area: Temperature rise |
SOP_EZ/2; ČSN 36 2255, čl. 176 až 192; POM_EZ/1; POM_EZ/2 | ||
| 6 | Rotating electrical machines | Measurement of temperature-rise, temperature and losses Regulated area: Temperature rise |
SOP_EZ/2; ČSN EN 60034-1 ed.2, čl. 8.3 až 8.10; POM_EZ/1; POM_EZ/2 | ||
| 7 | Electrical equipment of railway vehicles - Electrical components | Measurement of temperature-rise, temperature and losses Regulated area: Temperature rise |
SOP_EZ/2; ČSN EN 60077-1 ed.2, čl. 9.2.3, 9.3.2; ČSN EN 60077-2 ed.2, čl. 9.4.3, 9.3.3.3, 9.3.3.4, 9.3.3.8; ČSN EN IEC 60077-3 ed.2, čl. 9.3.3.4, 9.3.3.8; POM_EZ/1; POM_EZ/2 | ||
| 8 | Transformers and their parts | Measurement of temperature-rise, temperature and losses Regulated area: Temperature rise |
SOP_EZ/2; ČSN EN 60076-2 ed.2; ČSN EN 60076-6, čl. 10.9.6; ČSN EN IEC 60076-11 ed.2, čl. 14.3.2; ČSN EN 60310 ed.3, čl. 10, 13.2.9 až 13.2.11, 13.3.6, 13.3.8; ČSN EN 50329, čl. 2.2.3; POM_EZ/1; POM_EZ/2 | ||
| 9 | Switchgear and controlgear and parts thereof | Measurement of temperature-rise, temperature and losses Regulated area: Temperature rise |
SOP_EZ/2; ČSN EN 62271-1 ed.2, čl. 7.4, 7.5, 7.10.3, 8.4; ČSN EN IEC 62271-100 ed.3, čl. 7.4, 7.5, 7.10.3; ČSN EN IEC 62271-102 ed.2, čl. 7.4, 7.5, 8.4; ČSN EN 62271-103 ed.2, čl. 7.4, 7.5, 7.10.3; ČSN EN IEC 62271-200 ed.3, čl. 7.4, 7.5, 7.10.3, 8.4; ČSN EN 62271-202 ed.3, čl. 7.5; ČSN EN 60947-1 ed.5, čl. 9.3.3.3; ČSN EN 50123-1 ed.2, čl. 7.4; ČSN EN 50123-2 ed.2, čl. 8.3.4; ČSN EN 50123-3 ed.2, čl. 8.3.4; ČSN EN 50123-4 ed.2, čl. 8.3.4; ČSN EN 50123-6 ed.2, čl. 8.3.7; ČSN EN 50152-2 ed.3, čl. 7.1; POM_EZ/1; POM_EZ/2 | ||
| 10 | Semiconductor converters | Measurement of temperature-rise, temperature and losses Regulated area: Temperature rise |
SOP_EZ/2; ČSN EN 60146-1-1 ed.2, čl. 7.3.1, 7.3.2, 7.4.1, 7.4.2; ČSN EN 50328, čl. 4.2.2, 4.2.3, 4.2.4, 4.2.5; ČSN EN 61287-1 ed.2, čl. 4.5.3.13, 7.5.7; POM_EZ/1; POM_EZ/2 | ||
| 11 | Fuses | Measurement of temperature-rise, temperature and losses Regulated area: Temperature rise |
SOP_EZ/2; ČSN EN IEC 60282-1 ed.4, čl. 7.5; ČSN 35 4701-2 ed.3, čl. 8.3; ČSN EN 60269-1 ed.3, čl. 8.3; POM_EZ/1; POM_EZ/2 | ||
| 12 | Switchboards | Measurement of temperature-rise, temperature and losses Regulated area: Temperature rise |
SOP_EZ/2; ČSN EN IEC 61439-1 ed.3, čl. 10.10; ČSN EN IEC 61439-2 ed.3, čl. 10.10; POM_EZ/1; POM_EZ/2 | ||
| 13 | Railway equipment - Rolling stock - Pantograph collectors | Measurement of temperature-rise, temperature and losses Regulated area: Temperature rise |
SOP_EZ/2; ČSN EN 50206-1 ed.2, čl. 6.13; POM_EZ/1; POM_EZ/2 | ||
| 14 | Electrical machines and instruments | Test of making and breaking capacity, mechanical and functional tests, verification of strength Regulated area: Mechanical and function testing |
SOP_EZ/3; POM_EZ/2 | ||
| 15 | Electrical equipment of driving vehicles | Test of making and breaking capacity, mechanical and functional tests, verification of strength Regulated area: Mechanical and function testing |
SOP_EZ/3; ČSN 36 2255, čl. 153, 193 až 213; POM_EZ/2 | ||
| 16 | Metro traction lines | Test of making and breaking capacity, mechanical and functional tests, verification of strength Regulated area: Mechanical and function testing |
SOP_EZ/3; ČSN 33 3525, čl. 5.6.2; POM_EZ/2 | ||
| 17 | Rolling stock electrical equipment | Test of making and breaking capacity, mechanical and functional tests, verification of strength Regulated area: Mechanical and function testing |
SOP_EZ/3; ČSN EN 60077-1 ed.2, čl. 9.3.1, 9.3.4.1, 9.3.4.4, 9.3.8; ČSN EN 60077-2 ed.2, čl. 9.3.6, 9.3.7, 9.4.2, 9.3.3.2, 9.3.3.6, 9.3.4; ČSN EN IEC 60077-3 ed.2, čl. 9.3.3.2, 9.3.3.6, 9.3.4, 9.3.6, 9.3.7, 9.4.2; POM_EZ/2 | ||
| 18 | Fuses | Test of making and breaking capacity, mechanical and functional tests, verification of strength Regulated area: Mechanical and function testing |
SOP_EZ/3; ČSN EN IEC 60282-1 ed.4, čl. 7.6; POM_EZ/2 | ||
| 19 | Switchgear and controlgear | Test of making and breaking capacity, mechanical and functional tests, verification of strength Regulated area: Mechanical and function testing |
SOP_EZ/3; ČSN EN 60947-1 ed.5, čl. 9.3.3.5, 9.3.3.6, 9.3.3.7, 9.3.4; ČSN EN 60947-3 ed.4, čl. 9.3.4, 9.3.5, 9.3.8, 9.5; ČSN EN 62271-1 ed.2, čl. 7.10.2, 7.10.3, 7.10.4; ČSN EN IEC 62271-100 ed.3, čl. 7.10.2, 7.10.3, 7.10.4, 7.101, 7.102, 7.103.2, 7.105, 7.106, 7.107; ČSN EN IEC 62271-102 ed.2, čl. 7.101, 7.102, 7.103, 7.104; ČSN EN 62271-103 ed.2, čl. 7.10.2, 7.10.3, 7.10.4, 7.10.5, 7.101, 7.102, 8.102; ČSN EN IEC 62271-200 ed.3, čl. 7.10.2, 7.4.3, 7.10.3, 7.10.4, 7.101, 7.102, 8.102; ČSN EN 50123-1 ed.2, čl. 7.3, 7.8; ČSN EN 50123-2 ed.2, čl. 8.3.2, 8.3.6, 8.3.7, 8.3.8; ČSN EN 50123-3 ed.2, čl. 8.3.2, 8.3.5, 8.3.6, 8.3.9; ČSN EN 50123-4 ed.2, čl. 8.3.2, 8.3.5, 8.3.6, 8.3.8; ČSN EN 50123-6 ed.2, čl. 8.3.5, 8.3.8; PNE 35 4212 ed.2, čl. 9.6; POM_EZ/2 | ||
| 20 | Switchboards | Test of making and breaking capacity, mechanical and functional tests, verification of strength Regulated area: Mechanical and function testing |
SOP_EZ/3; ČSN EN IEC 61439-1 ed.3, čl. 10.2.8; ČSN EN IEC 61439-2 ed.3, čl. 10.2.8; POM_EZ/2 | ||
| 21 | Electrical machines and instruments | Test of short-circuit capacity Regulated area: Short-circuit capacity |
SOP_EZ/4; POM_EZ/2 | ||
| 22 | Electrical equipment of driving vehicles | Test of short-circuit capacity Regulated area: Short-circuit capacity |
SOP_EZ/4; ČSN 36 2255, čl. 214 až 219; POM_EZ/2 | ||
| 23 | Rolling stock electrical equipment | Test of short-circuit capacity Regulated area: Short-circuit capacity |
SOP_EZ/4; ČSN EN 60077-2 ed.2, čl. 9.3.4.2; POM_EZ/2 | ||
| 24 | Switchgear and controlgear | Test of short-circuit capacity Regulated area: Short-circuit capacity |
SOP_EZ/4; ČSN EN 50123-1 ed.2, čl. 7.6, 7.7; ČSN EN 50123-2 ed.2, čl. 8.3.9; ČSN EN 50123-3 ed.2, čl. 8.3.8; ČSN EN 50123-4 ed.2, čl. 8.3.1.2, 8.3.9; ČSN EN 50123-6 ed.2, čl. 8.3.4; ČSN EN 50152-2 ed.3, čl. 7.1; ČSN EN 62271-1 ed.2, čl. 7.6, 7.10.3; ČSN EN IEC 62271-100 ed.3, čl. 7.6, 7.10.3; ČSN EN IEC 62271-102 ed.2, čl. 7.6; ČSN EN 62271-103 ed.2, čl. 7.6, 7.10.3; ČSN EN IEC 62271-200 ed.3, čl. 7.6, 7.10.3, 7.105; ČSN EN 62271-202 ed.3, čl. 7.6, 7.102, Příloha A; ČSN EN 60947-1 ed.5, čl. 9.3.4; ČSN EN 60947-3 ed.4, čl. 9.3.6, 9.3.7; POM_EZ/2 | ||
| 25 | Fixed traction equipment - Overhead contact lines for electric traction | Test of short-circuit capacity Regulated area: Short-circuit capacity |
SOP_EZ/4; ČSN EN 50119 ed.3, čl. 8.11.1.3, 8.11.2; POM_EZ/2 | ||
| 26 | Switchboards | Test of short-circuit capacity Regulated area: Short-circuit capacity |
SOP_EZ/4; ČSN EN IEC 61439-1 ed.3, čl. 10.5, 10.11; ČSN EN IEC 61439-2 ed.3, čl. 10.5, 10.11; POM_EZ/2 | ||
| 27 | Low voltage surge protections | Test of short-circuit capacity Regulated area: Short-circuit capacity |
SOP_EZ/4; ČSN EN 61643-11 ed.2, čl. 8.3.5.3, 8.3.8.2; POM_EZ/2 | ||
| 28 | Semiconductor converters | Test of short-circuit capacity Regulated area: Short-circuit capacity |
SOP_EZ/4; ČSN EN 50328, čl. 4.2.9; POM_EZ/2 | ||
| 29 | Transformers and their parts | Test of short-circuit capacity Regulated area: Short-circuit capacity |
SOP_EZ/4; ČSN EN 60076-5 ed.2; ČSN EN IEC 60076-11 ed.2, čl. 14.4.3; ČSN EN 60076-6, čl. 11.8.13; ČSN EN 60310 ed.3, čl. 13.2.15, 13.3.12; ČSN EN 61869-2, čl. 7.2.201; ČSN EN 60076-13, čl. 12.4.9; POM_EZ/2 | ||
| 30 | Fuses | Test of short-circuit capacity Regulated area: Short-circuit capacity |
SOP_EZ/4; ČSN 35 4701-2 ed.3, čl. 8.5.5.1; POM_EZ/2 | ||
| 31 | Equipment with flowing or pressure liquid | Measurement of ventilation and hydraulic quantities Regulated area: Ventilation and hydraulic quantities |
SOP_EZ/5; ČSN ISO 7194:1994; POM_EZ/2 | ||
| 32 | Fans | Measurement of ventilation and hydraulic quantities Regulated area: Ventilation and hydraulic quantities |
SOP_EZ/5; ČSN 12 3061, čl. 28 až 36, 44 až 51, 65 až 84, 110 až 115; POM_EZ/2 | ||
| 33 | Semiconductor converters | Measurement of ventilation and hydraulic quantities Regulated area: Ventilation and hydraulic quantities |
SOP_EZ/5; ČSN EN 61287-1 ed.2, čl. 4.5.3.5.2, 4.5.3.5.3; POM_EZ/2 | ||
| 34 | Electrical machines, instruments | Dielectric tests Regulated area: Dielectric tests |
SOP_EZ/6; ČSN EN 60060-1; ČSN EN 60060-2 ed.2; ČSN EN 60270; ČSN EN 60052; ČSN EN 61083-1 ed.2; ČSN EN 61083-2 ed.2; ČSN EN 50124-1 ed.2, čl. 7.3, 7.4, 7.5, Příl. A, B, C, D; ČSN EN IEC 61133, čl. 8.7; POM_EZ/2 | ||
| 35 | Transformers and their parts | Dielectric tests Regulated area: Dielectric tests |
SOP_EZ/6; ČSN EN 60076-3 ed.2; ČSN EN 60076-4; ČSN EN IEC 60076-11 ed.2, čl. 14.2.5, 14.2.6, 14.3.1, 14.2.7, 14.4.1; ČSN EN 60310 ed.3, čl. 13.2.12, 13.2.13, 13.2.14, 13.3.9, 13.3.10, 13.3.11; POM_EZ/2 | ||
| 36 | Electrical equipment of driving vehicles | Dielectric tests Regulated area: Dielectric tests |
SOP_EZ/6; ČSN 36 2255, čl. 220 až 233; POM_EZ/2 | ||
| 37 | Switchgear and controlgear | Dielectric tests Regulated area: Dielectric tests |
SOP_EZ/6; ČSN EN 62271-1 ed.2, čl. 7.2, 7.10.5, 8.2, 8.3.4; ČSN EN IEC 62271-100 ed.3, čl. 7.2; ČSN EN IEC 62271-102 ed.2, čl. 7.2, 8.2, 8.3; ČSN EN 62271-103 ed.2, čl. 7.2, 7.10.5; ČSN EN IEC 62271-200 ed.3, čl. 7.2, 7.10.5, 7.104, 8.2, 8.3.4; ČSN EN 62271-202 ed.3, čl. 7.2, 8.2, 8.3.4; ČSN EN 60947-1 ed.5, čl. 9.3.3.4; ČSN EN 50123-1 ed.2, čl. 7.5; ČSN EN 50123-2 ed.2, čl. 8.3.3; ČSN EN 50123-3 ed.2, čl. 8.3.3; ČSN EN 50123-4 ed.2, čl. 8.3.3; ČSN EN 50123-6 ed.2, čl. 8.3.3; ČSN EN 50152-2 ed.3, čl. 7.2; PNE 35 4212, čl. 9.1, 9.2; POM_EZ/2 | ||
| 38 | Switchboards | Dielectric tests Regulated area: Dielectric tests |
SOP_EZ/6; ČSN EN IEC 61439-1 ed.3, čl. 10.9, 11.9; ČSN EN IEC 61439-2 ed.3, čl. 10.9, 11.9; POM_EZ/2 | ||
| 39 | Rolling stock electrical equipment | Dielectric tests Regulated area: Dielectric tests |
SOP_EZ/6; ČSN EN 60077-1 ed.2, čl. 9.3.3; ČSN EN 60077-2 ed.2, čl. 9.3.3.5, 9.4.5, 9.3.3.7, 9.3.5.5; ČSN EN IEC 60077-3 ed.2, čl. 9.3.3.5, 9.3.3.7, 9.3.4.8, 9.3.5.6, 9.4.6; POM_EZ/2 | ||
| 40 | Semiconductor converters | Dielectric tests Regulated area: Dielectric tests |
SOP_EZ/6; ČSN EN 60146-1-1 ed.2, čl. 7.2; ČSN EN 50328, čl. 4.2.1; ČSN EN 61287-1 ed.2, čl. 4.5.3.7, 4.5.3.8; POM_EZ/2 | ||
| 41 | Fuses | Dielectric tests Regulated area: Dielectric tests |
SOP_EZ/6; ČSN EN IEC 60282-1 ed.4, čl. 5.2.4, 7.4; POM_EZ/2 | ||
| 42 | Electrical machines, instruments | Verification of dimensions, weights, circuit layout and component fitting according to technical documentation Regulated area: Basic characteristics (dimensions, weight, circuit layout and component fitting) |
SOP_EZ/7; POM_EZ/2 | ||
| 43 | Rolling stock electrical equipment | Verification of dimensions, weights, circuit layout and component fitting according to technical documentation Regulated area: Basic characteristics (dimensions, weight, circuit layout and component fitting) |
SOP_EZ/7; ČSN EN 60077-1 ed.2, čl. 9.2.3; POM_EZ/2 | ||
| 44 | Switchgear and controlgear | Verification of dimensions, weights, circuit layout and component fitting according to technical documentation Regulated area: Basic characteristics (dimensions, weight, circuit layout and component fitting) |
SOP_EZ/7; ČSN EN 62271-1 ed.2, čl. 8.6; ČSN EN 50123-3 ed.2, čl. 8.3.1; POM_EZ/2 | ||
| 45 | Electrical machines, instruments | Measurement of electrical quantities (voltage, current, frequency, power, impedance, resistance, reactance, inductance, capacitance, phase shift, power factor, loss factor, time constant) Regulated area: Electrical quantities |
SOP_EZ/8; ČSN 42 0475; POM_EZ/2 | ||
| 46 | Transformers | Measurement of electrical quantities (voltage, current, frequency, power, impedance, resistance, reactance, inductance, capacitance, phase shift, power factor, loss factor, time constant) Regulated area: Electrical quantities |
SOP_EZ/8; ČSN EN 60076-1, čl. 11.2, 11.3, 11.4, 11.5; ČSN EN 60076-6, čl. 12.8.5; ČSN EN IEC 60076-11 ed.2, čl. 14.2.1, 14.2.2, 14.2.3, 14.2.4; ČSN EN 60310 ed.3, čl. 13.2.5 až 13.2.8, 13.3.5, 13.3.7; POM_EZ/2 | ||
Reference standards (147)
PNE 35 4212 ed.2, čl. 9.6
PNE 35 4212, čl. 9.1, 9.2
POM_EZ/1
POM_EZ/2
SOP_EZ/1
SOP_EZ/2
SOP_EZ/3
SOP_EZ/4
SOP_EZ/5
SOP_EZ/6
SOP_EZ/7
SOP_EZ/8
ČSN 12 3061, čl. 28 až 36, 44 až 51, 65 až 84, 110 až 115
ČSN 33 3525, čl. 5.6.2
ČSN 35 4701-2 ed.3, čl. 8.3
ČSN 35 4701-2 ed.3, čl. 8.5.5.1
ČSN 36 2255, čl. 153, 193 až 213
ČSN 36 2255, čl. 176 až 192
ČSN 36 2255, čl. 214 až 219
ČSN 36 2255, čl. 220 až 233
ČSN 42 0475
ČSN EN 50119 ed.3, čl. 8.11.1.3, 8.11.2
ČSN EN 50123-1 ed.2, čl. 7.3, 7.8
ČSN EN 50123-1 ed.2, čl. 7.4
ČSN EN 50123-1 ed.2, čl. 7.5
ČSN EN 50123-1 ed.2, čl. 7.6, 7.7
ČSN EN 50123-2 ed.2, čl. 8.3.2, 8.3.6, 8.3.7, 8.3.8
ČSN EN 50123-2 ed.2, čl. 8.3.3
ČSN EN 50123-2 ed.2, čl. 8.3.4
ČSN EN 50123-2 ed.2, čl. 8.3.9
ČSN EN 50123-3 ed.2, čl. 8.3.1
ČSN EN 50123-3 ed.2, čl. 8.3.2, 8.3.5, 8.3.6, 8.3.9
ČSN EN 50123-3 ed.2, čl. 8.3.3
ČSN EN 50123-3 ed.2, čl. 8.3.4
ČSN EN 50123-3 ed.2, čl. 8.3.8
ČSN EN 50123-4 ed.2, čl. 8.3.1.2, 8.3.9
ČSN EN 50123-4 ed.2, čl. 8.3.2, 8.3.5, 8.3.6, 8.3.8
ČSN EN 50123-4 ed.2, čl. 8.3.3
ČSN EN 50123-4 ed.2, čl. 8.3.4
ČSN EN 50123-6 ed.2, čl. 8.3.3
ČSN EN 50123-6 ed.2, čl. 8.3.4
ČSN EN 50123-6 ed.2, čl. 8.3.5, 8.3.8
ČSN EN 50123-6 ed.2, čl. 8.3.6
ČSN EN 50123-6 ed.2, čl. 8.3.7
ČSN EN 50124-1 ed.2, čl. 7.3, 7.4, 7.5, Příl. A, B, C, D
ČSN EN 50152-2 ed.3, čl. 7.1
ČSN EN 50152-2 ed.3, čl. 7.2
ČSN EN 50206-1 ed.2, čl. 6.13
ČSN EN 50328, čl. 4.2.1
ČSN EN 50328, čl. 4.2.2, 4.2.3, 4.2.4, 4.2.5
ČSN EN 50328, čl. 4.2.9
ČSN EN 50329, čl. 2.2.3
ČSN EN 60034-1 ed.2, čl. 8.3 až 8.10
ČSN EN 60052
ČSN EN 60060-1
ČSN EN 60060-2 ed.2
ČSN EN 60076-1, čl. 11.2, 11.3, 11.4, 11.5
ČSN EN 60076-13, čl. 12.4.9
ČSN EN 60076-2 ed.2
ČSN EN 60076-3 ed.2
ČSN EN 60076-4
ČSN EN 60076-5 ed.2
ČSN EN 60076-6, čl. 10.9.6
ČSN EN 60076-6, čl. 11.8.13
ČSN EN 60076-6, čl. 12.8.5
ČSN EN 60077-1 ed.2, čl. 9.2.3
ČSN EN 60077-1 ed.2, čl. 9.2.3, 9.3.2
ČSN EN 60077-1 ed.2, čl. 9.3.1, 9.3.4.1, 9.3.4.4, 9.3.8
ČSN EN 60077-1 ed.2, čl. 9.3.3
ČSN EN 60077-2 ed.2, čl. 9.3.3.5, 9.4.5, 9.3.3.7, 9.3.5.5
ČSN EN 60077-2 ed.2, čl. 9.3.4.2
ČSN EN 60077-2 ed.2, čl. 9.3.6, 9.3.7, 9.4.2, 9.3.3.2, 9.3.3.6, 9.3.4
ČSN EN 60077-2 ed.2, čl. 9.4.3, 9.3.3.3, 9.3.3.4, 9.3.3.8
ČSN EN 60146-1-1 ed.2, čl. 7.2
ČSN EN 60146-1-1 ed.2, čl. 7.3.1, 7.3.2, 7.4.1, 7.4.2
ČSN EN 60269-1 ed.3, čl. 8.3
ČSN EN 60270
ČSN EN 60310 ed.3, čl. 10, 13.2.9 až 13.2.11, 13.3.6, 13.3.8
ČSN EN 60310 ed.3, čl. 13.2.12, 13.2.13, 13.2.14, 13.3.9, 13.3.10, 13.3.11
ČSN EN 60310 ed.3, čl. 13.2.15, 13.3.12
ČSN EN 60310 ed.3, čl. 13.2.5 až 13.2.8, 13.3.5, 13.3.7
ČSN EN 60529
ČSN EN 60947-1 ed.5, čl. 9.3.3.3
ČSN EN 60947-1 ed.5, čl. 9.3.3.4
ČSN EN 60947-1 ed.5, čl. 9.3.3.5, 9.3.3.6, 9.3.3.7, 9.3.4
ČSN EN 60947-1 ed.5, čl. 9.3.4
ČSN EN 60947-3 ed.4, čl. 9.3.4, 9.3.5, 9.3.8, 9.5
ČSN EN 60947-3 ed.4, čl. 9.3.6, 9.3.7
ČSN EN 61083-1 ed.2
ČSN EN 61083-2 ed.2
ČSN EN 61287-1 ed.2, čl. 4.5.3.13, 7.5.7
ČSN EN 61287-1 ed.2, čl. 4.5.3.5.2, 4.5.3.5.3
ČSN EN 61287-1 ed.2, čl. 4.5.3.7, 4.5.3.8
ČSN EN 61643-11 ed.2, čl. 8.3.5.3, 8.3.8.2
ČSN EN 61869-2, čl. 7.2.201
ČSN EN 62271-1 ed.2, čl. 7.10.2, 7.10.3, 7.10.4
ČSN EN 62271-1 ed.2, čl. 7.2, 7.10.5, 8.2, 8.3.4
ČSN EN 62271-1 ed.2, čl. 7.4, 7.5, 7.10.3, 8.4
ČSN EN 62271-1 ed.2, čl. 7.6, 7.10.3
ČSN EN 62271-1 ed.2, čl. 7.7.1
ČSN EN 62271-1 ed.2, čl. 8.6
ČSN EN 62271-103 ed.2, čl. 7.10.2, 7.10.3, 7.10.4, 7.10.5, 7.101, 7.102, 8.102
ČSN EN 62271-103 ed.2, čl. 7.2, 7.10.5
ČSN EN 62271-103 ed.2, čl. 7.4, 7.5, 7.10.3
ČSN EN 62271-103 ed.2, čl. 7.6, 7.10.3
ČSN EN 62271-103 ed.2, čl. 7.7
ČSN EN 62271-202 ed.3, čl. 7.2, 8.2, 8.3.4
ČSN EN 62271-202 ed.3, čl. 7.5
ČSN EN 62271-202 ed.3, čl. 7.6, 7.102, Příloha A
ČSN EN 62271-202 ed.3, čl. 7.7
ČSN EN IEC 60076-11 ed.2, čl. 14.2.1, 14.2.2, 14.2.3, 14.2.4
ČSN EN IEC 60076-11 ed.2, čl. 14.2.5, 14.2.6, 14.3.1, 14.2.7, 14.4.1
ČSN EN IEC 60076-11 ed.2, čl. 14.3.2
ČSN EN IEC 60076-11 ed.2, čl. 14.4.3
ČSN EN IEC 60077-3 ed.2, čl. 9.3.3.2, 9.3.3.6, 9.3.4, 9.3.6, 9.3.7, 9.4.2
ČSN EN IEC 60077-3 ed.2, čl. 9.3.3.4, 9.3.3.8
ČSN EN IEC 60077-3 ed.2, čl. 9.3.3.5, 9.3.3.7, 9.3.4.8, 9.3.5.6, 9.4.6
ČSN EN IEC 60282-1 ed.4, čl. 5.2.4, 7.4
ČSN EN IEC 60282-1 ed.4, čl. 7.5
ČSN EN IEC 60282-1 ed.4, čl. 7.6
ČSN EN IEC 61133, čl. 8.7
ČSN EN IEC 61439-1 ed.3, čl. 10.10
ČSN EN IEC 61439-1 ed.3, čl. 10.2.8
ČSN EN IEC 61439-1 ed.3, čl. 10.3
ČSN EN IEC 61439-1 ed.3, čl. 10.5, 10.11
ČSN EN IEC 61439-1 ed.3, čl. 10.9, 11.9
ČSN EN IEC 61439-2 ed.3, čl. 10.10
ČSN EN IEC 61439-2 ed.3, čl. 10.2.8
ČSN EN IEC 61439-2 ed.3, čl. 10.3
ČSN EN IEC 61439-2 ed.3, čl. 10.5, 10.11
ČSN EN IEC 61439-2 ed.3, čl. 10.9, 11.9
ČSN EN IEC 62271-100 ed.3, čl. 7.10.2, 7.10.3, 7.10.4, 7.101, 7.102, 7.103.2, 7.105, 7.106, 7.107
ČSN EN IEC 62271-100 ed.3, čl. 7.2
ČSN EN IEC 62271-100 ed.3, čl. 7.4, 7.5, 7.10.3
ČSN EN IEC 62271-100 ed.3, čl. 7.6, 7.10.3
ČSN EN IEC 62271-100 ed.3, čl. 7.7.1
ČSN EN IEC 62271-102 ed.2, čl. 7.101, 7.102, 7.103, 7.104
ČSN EN IEC 62271-102 ed.2, čl. 7.2, 8.2, 8.3
ČSN EN IEC 62271-102 ed.2, čl. 7.4, 7.5, 8.4
ČSN EN IEC 62271-102 ed.2, čl. 7.6
ČSN EN IEC 62271-102 ed.2, čl. 7.7
ČSN EN IEC 62271-200 ed.3, čl. 7.10.2, 7.4.3, 7.10.3, 7.10.4, 7.101, 7.102, 8.102
ČSN EN IEC 62271-200 ed.3, čl. 7.2, 7.10.5, 7.104, 8.2, 8.3.4
ČSN EN IEC 62271-200 ed.3, čl. 7.4, 7.5, 7.10.3, 8.4
ČSN EN IEC 62271-200 ed.3, čl. 7.6, 7.10.3, 7.105
ČSN EN IEC 62271-200 ed.3, čl. 7.7.1
ČSN ISO 7194:1994