🇨🇿 GeoTec-GS, a.s. PL

ČIA 1514 • Brno - Maloměřice, Czech Republic • 60 methods

Construction

GeoTec-GS, a.s. is a laboratory accredited by ČIA under number 1514 (Brno - Maloměřice, Czech Republic). Its accreditation scope covers 60 test methods in the following areas: Construction. Test objects include: Soils, fly ash, slags, Soils, Aggregate, Soils, aggregate, fly ash, slags.

At a glance

  • Accreditation number: ČIA 1514
  • Methods in scope: 60
  • Types of test objects: 20
  • City: Brno - Maloměřice, Czech Republic
  • Valid until: 18-12-2029
Accreditation number
1514
Accreditation body
ČIA
Address
Franzova 922/70, 614 00 Brno - Maloměřice
City
Brno - Maloměřice, Czech Republic
Division
Laboratorium Geotechniki i Monitoringu
Valid until
18-12-2029

What this laboratory tests (20)

Laboratory sections (4)

Laboratory locations

Certificate information

Certificate date
22.05.2026

Accreditation scope — test methods (60)

No. Test object Methodology / Parameters Technique Reference document
Field Testing Laboratory
1 Soils, fly ash, slags Determination of water content
Regulated area: Tests
ČSN EN ISO 17892-1
2 Soils In-situ determination of bulk density with a membrane volumeter
Regulated area: Tests
ČSN 72 1010, metoda D-1, A
3 Soils, structural layers Static plate load test
Regulated area: Tests
ČSN 72 1006, příl. A, B a D
4 Soils, structural layers Impact load test with light dynamic plate
Regulated area: Tests
ČSN 73 6192, čl. 5.4
5 Structural layers, soils Geodetic control method
Regulated area: Tests
ČSN 72 1006, příl. G
Soil Mechanics Laboratory
6 Soils, fly ash, slags Determination of water content
Regulated area: Tests
ČSN EN ISO 17892-1
7 Soils, fly ash, slags Determination of bulk density
Regulated area: Tests
ČSN EN ISO 17892-2
8 Soils, crushed aggregate, fly ash, slags Determination of particle density of solid particles
Regulated area: Tests
ČSN EN ISO 17892-3
9 Soils, fly ash, slags Determination of particle size distribution and calculation of coefficient of uniformity, coefficient of curvature and capillary rise from measured values
coefficient of uniformity (calculated), coefficient of curvature (calculated), capillary rise (calculated)
Regulated area: Tests
ČSN EN ISO 17892-4; PP-06 (Mechanika zemin a zakládání staveb, 2003); PP-05 (TP 170)
10 Soils Determination of liquid limit, plastic limit and calculation of plasticity index and consistency index from measured values
plasticity index (calculated), consistency index (calculated)
Regulated area: Tests
ČSN EN ISO 17892-12
11 Soils Determination of loss on ignition
Regulated area: Tests
ČSN EN 13039
12 Soils, fly ash, slags Calculation of porosity and degree of saturation from measured values
porosity (calculated), degree of saturation (calculated)
Regulated area: Tests
PP-07 (Mechanika zemin a zakládání staveb, 2003)
13 Soils, fly ash, slags Determination of compressibility by oedometer
Regulated area: Tests
ČSN EN ISO 17892-5
14 Soils, fly ash, slags Determination of swelling pressure
Regulated area: Tests
ČSN CEN ISO/TS 17892-5:2005
15 Soils, fly ash, slags Determination of swelling
Regulated area: Tests
PP-01 (ČSN EN ISO 17892-5; Metodika I ČGÚ, kap. 20, 1987)
16 Soils, fly ash, slags Determination of collapsibility
Regulated area: Tests
PP-02 (ČSN EN ISO 17892-5; Metodika I ČGÚ, kap. 19.13, 1987)
17 Soils, fly ash, slags Direct shear box test
Regulated area: Tests
ČSN EN ISO 17892-10
18 Soils, aggregate, fly ash, slags Proctor test – determination of compactability
Regulated area: Tests
ČSN EN 13286-2, mimo čl. 7.3 a 7.6
19 Soils, aggregate, fly ash, slags Determination of California bearing ratio (CBR), immediate bearing index (IBI) and linear swelling
Regulated area: Tests
ČSN EN 13286-47
20 Aggregate Determination of water content
Regulated area: Tests
ČSN EN 1097-5
Soil Mechanics, Field Testing and Monitoring Laboratory
21 Soils, fly ash, slags Determination of water content
Regulated area: Tests
ČSN EN ISO 17892-1
22 Soils, fly ash, slags Determination of bulk density
Regulated area: Tests
ČSN EN ISO 17892-2
23 Soils, crushed aggregate, fly ash, slags Determination of particle density of solid particles
Regulated area: Tests
ČSN EN ISO 17892-3
24 Soils, fly ash, slags Determination of particle size distribution and calculation of coefficient of uniformity, coefficient of curvature and capillary rise from measured values
coefficient of uniformity (calculated), coefficient of curvature (calculated), capillary rise (calculated)
Regulated area: Tests
ČSN EN ISO 17892-4; PP-06 (Mechanika zemin a zakládání staveb, 2003); PP-05 (TP 170)
25 Soils Determination of liquid limit, plastic limit and calculation of plasticity index and consistency index from measured values
plasticity index (calculated), consistency index (calculated)
Regulated area: Tests
ČSN EN ISO 17892-12
26 Soils Determination of loss on ignition
Regulated area: Tests
ČSN EN 13039
27 Soils, fly ash, slags Calculation of porosity and degree of saturation from measured values
porosity (calculated), degree of saturation (calculated)
Regulated area: Tests
PP-07 (Mechanika zemin a zakládání staveb, 2003)
28 Soils, fly ash, slags Determination of compressibility by oedometer
Regulated area: Tests
ČSN EN ISO 17892-5
29 Soils, fly ash, slags Determination of swelling pressure
Regulated area: Tests
ČSN CEN ISO/TS 17892-5:2005
30 Soils, fly ash, slags Determination of swelling
Regulated area: Tests
PP-01 (ČSN EN ISO 17892-5; Metodika I ČGÚ, kap. 20, 1987)
31 Soils, fly ash, slags Determination of collapsibility
Regulated area: Tests
PP-02 (ČSN EN ISO 17892-5; Metodika I ČGÚ, kap. 19.13, 1987)
32 Soils, fly ash, slags Direct shear box test
Regulated area: Tests
ČSN EN ISO 17892-10
33 Soils, aggregate, fly ash, slags Proctor test – determination of compactability
Regulated area: Tests
ČSN EN 13286-2, mimo čl. 7.3 a 7.6
34 Soils, aggregate, fly ash, slags Determination of California bearing ratio (CBR), immediate bearing index (IBI) and linear swelling
Regulated area: Tests
ČSN EN 13286-47
35 Aggregate Determination of water content
Regulated area: Tests
ČSN EN 1097-5
36 Aggregate Determination of particle size distribution
Regulated area: Tests
ČSN EN 933-1
37 Soils, aggregate Determination of relative density
Regulated area: Tests
ČSN 72 1018
38 Soils In-situ determination of bulk density with a membrane volumeter
Regulated area: Tests
ČSN 72 1010, metoda D-1, A
39 Soils, structural layers Static plate load test
Regulated area: Tests
ČSN 72 1006, příl. A, B a D
40 Soils, structural layers Impact load test with light dynamic plate
Regulated area: Tests
ČSN 73 6192, čl. 5.4
41 Soils Dynamic probing test
Regulated area: Tests
ČSN EN ISO 22476-2
42 Building and earth structures Force measurement with electrical load cells – dynamometers
Regulated area: Tests
PP-30 (ČSN EN ISO 18674-1; ČSN EN ISO 18674-8)
43 Concrete structures Strain – stress measurement in concrete structures – strain gauges
Regulated area: Tests
PP-31 (ČSN EN ISO 18674-1)
44 Earth structures Deformation measurement – measurement of subsoil settlement by hydrostatic levelling
Regulated area: Tests
PP-32 (ČSN EN ISO 18674-1)
45 Building and earth structures, soils Inclinometer measurements
Regulated area: Tests
PP-33 (ČSN EN ISO 18674-3; ČSN EN ISO 18674-1)
46 Building structures Tilt measurement
Regulated area: Tests
PP-34 (ČSN EN ISO 18674-1)
47 Water Measurement of pore water pressure with piezometers
Regulated area: Tests
PP-35 (ČSN EN ISO 18674-4; ČSN EN ISO 18674-1)
48 Soils, building structures Measurement of stress change with total pressure sensor – pressure cells
Regulated area: Tests
PP-36 (ČSN EN ISO 18674-5; ČSN EN ISO 18674-1)
49 Building structures, rocks Measurement of linear displacements with dilatometers
Regulated area: Tests
PP-37 (ČSN EN ISO 18674-1)
50 Building structures, soils, rocks Measurement of linear displacements with extensometers
Regulated area: Tests
PP-38 (ČSN EN ISO 18674-2; ČSN EN ISO 18674-1)
Rock Mechanics Laboratory
51 Aggregate Determination of water content
Regulated area: Tests
ČSN EN 1097-5
52 Aggregate Determination of particle size distribution
Regulated area: Tests
ČSN EN 933-1
53 Soils, aggregate Determination of relative density
Regulated area: Tests
ČSN 72 1018
54 Soils, aggregate Determination of maximum dry density
Regulated area: Tests
ČSN EN 13286-5
55 Hardened concrete Determination of bulk density
Regulated area: Tests
ČSN EN 12390-7
56 Stone Determination of bulk density
Regulated area: Tests
PP-04 (Metodika III ČGÚ, 1987)
57 Hardened concrete Determination of uniaxial compressive strength
Regulated area: Tests
ČSN EN 12504-1
58 Stone Determination of uniaxial compressive strength
Regulated area: Tests
ČSN EN 1926
59 Stone Determination of compressive strength on rocks and fragments (point load)
Regulated area: Tests
ASTM D5731-16
60 Stone, concrete Determination of indirect tensile strength on rock specimens
Regulated area: Tests
ČSN EN 12390-6

Reference standards (49)

ASTM D5731-16
Mechanika zemin a zakládání staveb, 2003
Metodika I ČGÚ
Metodika III ČGÚ
PP-01
PP-02
PP-04
PP-05
PP-06
PP-07
PP-30
PP-31
PP-32
PP-33
PP-34
PP-35
PP-36
PP-37
PP-38
TP 170
ČSN 72 1006
ČSN 72 1010
ČSN 72 1018
ČSN 73 6192
ČSN CEN ISO/TS 17892-5:2005
ČSN EN 1097-5
ČSN EN 12390-6
ČSN EN 12390-7
ČSN EN 12504-1
ČSN EN 13039
ČSN EN 13286-2
ČSN EN 13286-47
ČSN EN 13286-5
ČSN EN 1926
ČSN EN 933-1
ČSN EN ISO 17892-1
ČSN EN ISO 17892-10
ČSN EN ISO 17892-12
ČSN EN ISO 17892-2
ČSN EN ISO 17892-3
ČSN EN ISO 17892-4
ČSN EN ISO 17892-5
ČSN EN ISO 18674-1
ČSN EN ISO 18674-2
ČSN EN ISO 18674-3
ČSN EN ISO 18674-4
ČSN EN ISO 18674-5
ČSN EN ISO 18674-8
ČSN EN ISO 22476-2

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1514