🇨🇿 K FAKTOR s.r.o. PL

ČIA 1486 • Ústí nad Labem - Předlice, Czech Republic • 8 methods

Environment

K FAKTOR s.r.o. is a laboratory accredited by ČIA under number 1486 (Ústí nad Labem - Předlice, Czech Republic). Its accreditation scope covers 8 test methods in the following areas: Environment. Test objects include: Working environment, Artificial and daylighting of indoor and outdoor areas, Enclosed spaces of buildings, Indoor and working environment. Most frequently used techniques: Gravimetric method.

At a glance

  • Accreditation number: ČIA 1486
  • Methods in scope: 8
  • Types of test objects: 5
  • Techniques used: 1
  • City: Ústí nad Labem - Předlice, Czech Republic
  • Valid until: 27-02-2030
Accreditation number
1486
Accreditation body
ČIA
Address
Hrbovická 155/14, 400 01 Ústí nad Labem - Předlice
City
Ústí nad Labem - Předlice, Czech Republic
Division
Laboratorium Badawcze Pomiarów Czynników Fizycznych
Valid until
27-02-2030

What this laboratory tests (5)

Analytical techniques used (1)

Certificate information

Certificate date
10.07.2025

Accreditation scope — test methods (8)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Artificial and daylighting of indoor and outdoor areas Measurement and calculation of lighting
Regulated area: Tests
- stanovení měřením: ČSN 36 0011-2; ČSN 36 0011-3; ČSN 36 0011-4; - stanovení výpočtem: ČSN 36 0020; ČSN 73 0580-1; ČSN 73 0580-2; ČSN 73 0580-3; ČSN 73 0580-4; ČSN EN 12464-1; ČSN EN 12464-2; ČSN EN 17037
2 Working environment Measurement of noise
Regulated area: Tests
ČSN EN ISO 9612; ČSN ISO 1999; Věstník MZ ČR č. 4/2013, část 4
3 Non-working environment Measurement of noise
Regulated area: Tests
ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR č. 14/2023, část 3
4 Working environment Measurement of vibrations
Regulated area: Tests
ČSN EN ISO 5349-1; ČSN EN ISO 5349-2; ČSN EN 14253+A1; ČSN ISO 2631-1; Věstník MZ ČR č. 4/2013, část 4
5 Working environment Determination of inhalable and respirable dust fractions
Regulated area: Tests
Gravimetric method PP 12A.05 (ČSN EN 481; ČSN EN 482+A1; NV č. 361/2007 Sb., příl. č. 3)
6 Indoor and working environment Measurement of microclimatic conditions
Regulated area: Tests
ČSN EN ISO 7726; Věstník MZ ČR č. 8/2013, část 2
7 Enclosed spaces of buildings Measurement of reverberation time
Regulated area: Tests
ČSN EN ISO 3382-2; ČSN EN ISO 3382-3
8 Working environment Sampling of inhalable and respirable dust fractions
Regulated area: Sampling
PP 12A.05 (ČSN EN 481; ČSN EN 482+A1; NV č. 361/2007 Sb., příl. č. 3)

Reference standards (29)

NV č. 361/2007 Sb., příl. č. 3
PP 12A.05
Věstník MZ ČR č. 14/2023, část 3
Věstník MZ ČR č. 4/2013, část 4
Věstník MZ ČR č. 8/2013, část 2
ČSN 36 0011-2
ČSN 36 0011-3
ČSN 36 0011-4
ČSN 36 0020
ČSN 73 0580-1
ČSN 73 0580-2
ČSN 73 0580-3
ČSN 73 0580-4
ČSN EN 12464-1
ČSN EN 12464-2
ČSN EN 14253+A1
ČSN EN 17037
ČSN EN 481
ČSN EN 482+A1
ČSN EN ISO 3382-2
ČSN EN ISO 3382-3
ČSN EN ISO 5349-1
ČSN EN ISO 5349-2
ČSN EN ISO 7726
ČSN EN ISO 9612
ČSN ISO 1996-1
ČSN ISO 1996-2
ČSN ISO 1999
ČSN ISO 2631-1

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1486