🇨🇿 Vodovody a kanalizace Trutnov, a.s. PL

ČIA 1456 • 541 03 Trutnov 3, Czech Republic • 39 methods

Water & wastewaterMicrobiology

Vodovody a kanalizace Trutnov, a.s. is a laboratory accredited by ČIA under number 1456 (541 03 Trutnov 3, Czech Republic). Its accreditation scope covers 39 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Drinking, surface, ground and raw water, Drinking, surface, ground, raw and waste water, Surface, raw and waste water, Drinking water. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Gravimetric method.

At a glance

  • Accreditation number: ČIA 1456
  • Methods in scope: 39
  • Types of test objects: 7
  • Techniques used: 20
  • City: 541 03 Trutnov 3, Czech Republic
  • Valid until: 16-02-2028
Accreditation number
1456
Accreditation body
ČIA
Address
Kladská 106, Bohuslavice nad Úpou, 541 03 Trutnov 3
City
541 03 Trutnov 3, Czech Republic
Division
Laboratorium Hydrolab
Valid until
16-02-2028

What this laboratory tests (7)

Analytical techniques used (20)

Certificate information

Certificate date
16.05.2025

Accreditation scope — test methods (39)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Drinking, surface, ground and raw water Determination of absorbance
Regulated area: Tests
Spectrophotometric method SOP CH 1 (ČSN 75 7360)
2 Drinking, surface, ground, raw and waste water Determination of ammonium ions
Ammoniacal nitrogen (calculated) (calculated), Inorganic nitrogen (calculated) (calculated)
Regulated area: Tests
Manual spectrophotometric method SOP CH 2 (ČSN ISO 7150-1)
3 Surface, raw and waste water Determination of total phosphorus
Regulated area: Tests
Manual spectrophotometric method SOP CH 3 (ČSN EN ISO 6878, kap. 7)
4 Drinking, surface, ground, raw and waste water Determination of nitrate
Nitrate nitrogen (calculated) (calculated)
Regulated area: Tests
Spectrophotometric method with sulfosalicylic acid SOP CH 4 (ČSN ISO 7890-3)
5 Drinking, surface, ground and raw water Determination of nitrate
Regulated area: Tests
Spectrophotometric method in the UV region SOP CH 5 (Horáková a kol.: Chemické a fyzikální metody analýzy vod, VŠCHT Praha 2007, kap. 4.1.2)
6 Drinking, surface, ground, raw and waste water Determination of nitrite
Nitrite nitrogen (calculated) (calculated)
Regulated area: Tests
Spectrophotometric method SOP CH 6 (ČSN EN 26777)
7 Drinking, surface, ground, raw and waste water Determination of orthophosphate
Phosphate phosphorus (calculated) (calculated)
Regulated area: Tests
Spectrophotometric method SOP CH 7 (ČSN EN ISO 6878, kap. 4)
8 Drinking, surface, ground and raw water Determination of chloride
Regulated area: Tests
Titration by Mohr's method SOP CH 8 (ČSN ISO 9297)
9 Surface, raw and waste water Determination of chemical oxygen demand (CODCr)
Regulated area: Tests
Spectrophotometric dichromate semi-micro method SOP CH 9 (ČSN ISO 15705)
10 Drinking, surface, ground and raw water Determination of chemical oxygen demand (CODMn, permanganate index)
Regulated area: Tests
Titration with potassium permanganate SOP CH 10 (ČSN EN ISO 8467)
11 Drinking, surface, ground, raw and waste water Determination of electrical conductivity
Regulated area: Tests
SOP CH 11 (ČSN EN 27888)
12 Drinking, surface, ground and raw water Determination of manganese
Regulated area: Tests
Spectrophotometric method SOP CH 12 (ČSN ISO 6333)
13 Surface, raw and waste water Determination of suspended solids
Regulated area: Tests
Gravimetric method SOP CH 13 (ČSN EN 872)
14 Drinking, surface, ground, raw and waste water Determination of water reaction (pH)
Regulated area: Tests
Potentiometric method SOP CH 14 (ČSN EN ISO 10523)
15 Surface, raw and waste water Determination of dissolved dried solids (RL105) and dissolved inorganic salts (RAS)
Dissolved dried solids (RL105) Dissolved inorganic salts (RAS)
Regulated area: Tests
Gravimetric method SOP CH 15 (ČSN 75 7346; ČSN 75 7347)
16 Drinking, surface, ground and raw water Determination of sulphate
Regulated area: Tests
Titrimetric method with lead nitrate SOP CH 16 (ČSN 75 7477)
17 Drinking, surface, ground and raw water Determination of the sum of calcium and magnesium
Magnesium (calculated) (calculated)
Regulated area: Tests
Titrimetric method with EDTA SOP CH 17 (ČSN ISO 6059)
18 Drinking, surface, ground and raw water Determination of calcium
Regulated area: Tests
Titrimetric method with EDTA SOP CH 18 (ČSN ISO 6058)
19 Drinking, surface, ground and raw water Determination of dissolved fluoride
Regulated area: Tests
Spectrophotometric method SOP CH 38 (TNV 75 7431)
20 Drinking, surface, ground and raw water Determination of iron
Regulated area: Tests
Photometric method with 1,10-phenanthroline SOP CH 20 (ČSN ISO 6332)
21 Drinking, surface, ground and raw water Determination of aluminium
Regulated area: Tests
Spectrophotometric method SOP CH 21 (ČSN ISO 10566)
22 Drinking, surface, ground and raw water Determination of colour
Regulated area: Tests
Spectrophotometric method SOP CH 22 (ČSN EN ISO 7887)
23 Drinking, surface, ground and raw water Determination of acid neutralizing capacity (ANC4.5, alkalinity)
Regulated area: Tests
Titrimetric method SOP CH 23 (ČSN EN ISO 9963-1)
24 Drinking, surface, ground and raw water Indicative sensory assessment of odour and taste
Odour Taste
Regulated area: Tests
SOP CH 24 (ČSN 75 7340; ČSN EN 1622)
25 Drinking water Determination of free and total chlorine
Free chlorine Total chlorine
Combined chlorine (calculated) (calculated)
Regulated area: Tests
Spectrophotometric method using a Hach set SOP CH 25 (ČSN EN ISO 7393-2; návod firmy Hach)
26 Drinking, surface, ground and raw water Determination of Escherichia coli and coliform bacteria
Escherichia coli Coliform bacteria
Regulated area: Tests
Membrane filtration method SOP MB 7 (ČSN EN ISO 9308-1)
27 Surface, ground and raw water Determination of thermotolerant coliform bacteria and Escherichia coli
Thermotolerant coliform bacteria Escherichia coli
Regulated area: Tests
Membrane filtration method SOP MB 2 (ČSN 75 7835)
28 Drinking, surface, ground and raw water Determination of intestinal enterococci
Regulated area: Tests
Membrane filtration method SOP MB 3 (ČSN EN ISO 7899-2)
29 Drinking, surface, ground and raw water Enumeration of culturable microorganisms at 36 °C and 22 °C
Culturable microorganisms at 36 °C Culturable microorganisms at 22 °C
Regulated area: Tests
Culture method SOP MB 4 (ČSN EN ISO 6222)
30 Drinking, surface, ground and raw water Determination of Clostridium perfringens
Regulated area: Tests
Membrane filtration method SOP MB 1 (ČSN EN ISO 14189)
31 Drinking, surface, ground and raw water Determination of turbidity
Regulated area: Tests
Nephelometric method SOP CH 39 (ČSN EN ISO 7027-1; návod firmy Hach)
32 Drinking, surface, ground and raw water Determination of humic substances
Regulated area: Tests
Spectrophotometric method SOP CH 27 (ČSN 75 7536)
33 Drinking, surface, ground and raw water Determination of base neutralizing capacity (BNC8.3, acidity)
Regulated area: Tests
Titrimetric method SOP CH 28 (ČSN 75 7372)
34 Drinking, surface, ground, raw and waste water Determination of biochemical oxygen demand (BOD5)
Regulated area: Tests
Optical sensor method SOP CH 40 (ČSN EN ISO 5815-1; ČSN ISO 17289; ČSN EN 1899-2)
35 Surface, raw and waste water Determination of total nitrogen
Regulated area: Tests
Spectrophotometric method SOP CH 30 (ČSN EN ISO 11905-1; ČSN 75 7455)
36 Drinking, surface, ground and raw water Determination of bioseston
Regulated area: Tests
Microscopic method SOP B 1 (ČSN 75 7712)
37 Drinking, surface, ground and raw water Determination of abioseston
Regulated area: Tests
Microscopic method SOP B 2 (ČSN 75 7713)
38 Drinking water, and surface and raw water intended for drinking water production Sampling of drinking water
Regulated area: Sampling
SOP V 1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.)
39 Waste water Sampling of waste water
Regulated area: Sampling
Manual sampling and sampling with an automatic sampler SOP V 2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)

Reference standards (90)

Horáková a kol.: Chemické a fyzikální metody analýzy vod, VŠCHT Praha 2007, kap. 4.1.2
SOP B 1
SOP B 2
SOP CH 1
SOP CH 10
SOP CH 11
SOP CH 12
SOP CH 13
SOP CH 14
SOP CH 15
SOP CH 16
SOP CH 17
SOP CH 18
SOP CH 2
SOP CH 20
SOP CH 21
SOP CH 22
SOP CH 23
SOP CH 24
SOP CH 25
SOP CH 27
SOP CH 28
SOP CH 3
SOP CH 30
SOP CH 38
SOP CH 39
SOP CH 4
SOP CH 40
SOP CH 5
SOP CH 6
SOP CH 7
SOP CH 8
SOP CH 9
SOP MB 1
SOP MB 2
SOP MB 3
SOP MB 4
SOP MB 7
SOP V 1
SOP V 2
TNV 75 7431
Vyhláška č. 252/2004 Sb.
návod firmy Hach
ČSN 75 7315
ČSN 75 7340
ČSN 75 7346
ČSN 75 7347
ČSN 75 7360
ČSN 75 7372
ČSN 75 7455
ČSN 75 7477
ČSN 75 7536
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN EN 1622
ČSN EN 1899-2
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 10523
ČSN EN ISO 11905-1
ČSN EN ISO 14189
ČSN EN ISO 19458
ČSN EN ISO 5667-1
ČSN EN ISO 5667-14
ČSN EN ISO 5667-3
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878, kap. 4
ČSN EN ISO 6878, kap. 7
ČSN EN ISO 7027-1
ČSN EN ISO 7393-2
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9963-1
ČSN ISO 10566
ČSN ISO 15705
ČSN ISO 17289
ČSN ISO 5667-10
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 9297

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1456