🇨🇿 Královéhradecká provozní, a.s. PL

ČIA 1454 • Hradec Králové, Czech Republic • 38 methods

Water & wastewaterMicrobiology

Královéhradecká provozní, a.s. is a laboratory accredited by ČIA under number 1454 (Hradec Králové, Czech Republic). Its accreditation scope covers 38 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Drinking, ground and surface water, Waste water, Drinking, ground, surface and waste water, Drinking and surface water.

At a glance

  • Accreditation number: ČIA 1454
  • Methods in scope: 38
  • Types of test objects: 7
  • City: Hradec Králové, Czech Republic
  • Valid until: 06-02-2028
Accreditation number
1454
Accreditation body
ČIA
Address
V Mlejnku 625, 500 11 Hradec Králové
City
Hradec Králové, Czech Republic
Division
Laboratorium Wód Pitnych
Valid until
06-02-2028

What this laboratory tests (7)

Laboratory sections (2)

Laboratory locations

Certificate information

Certificate date
01.07.2025

Accreditation scope — test methods (38)

No. Test object Methodology / Parameters Technique Reference document
Drinking Water Laboratory
1 Drinking and ground water Indicative sensory determination of odour and taste
Regulated area: Tests
SOP-OST 35 (ČSN EN 1622; TNV 75 7340)
2 Drinking water Determination of free and total chlorine by photometry with a commercial Hach kit
combined chlorine by calculation (calculated)
Regulated area: Tests
SOP-CH 9 (ČSN ISO 7393-2; Návod firmy Hach)
3 Drinking, ground and surface water Determination of colour by photometry
Regulated area: Tests
SOP-CH 12 (ČSN EN ISO 7887)
4 Drinking, ground and surface water Determination of turbidity by nephelometry
Regulated area: Tests
SOP-CH 13 (ČSN EN ISO 7027)
5 Drinking, ground, surface and waste water Determination of pH by potentiometry
Regulated area: Tests
SOP-CH 10 (ČSN ISO 10523)
6 Drinking, ground and surface water Determination of electrical conductivity
Regulated area: Tests
SOP-CH 11 (ČSN EN 27888)
7 Drinking, ground and surface water Determination of total manganese by photometry
Regulated area: Tests
SOP-CH 15 (ČSN ISO 6333)
8 Drinking, ground and surface water Determination of total iron by photometry
Regulated area: Tests
SOP-CH 14 (ČSN ISO 6332)
9 Drinking, ground, surface and waste water Determination of nitrite by photometry and of nitrite nitrogen by calculation
Regulated area: Tests
SOP-CH 17 (ČSN EN 26777)
10 Drinking, ground, surface and waste water Determination of ammonium ions by photometry and of ammonium nitrogen by calculation
Regulated area: Tests
SOP-CH 16 (ČSN ISO 7150-1)
11 Drinking, ground and surface water Determination of nitrate by direct UV photometry
Regulated area: Tests
SOP-CH 18 (Vodní hospodářství č. 2 1988)
12 Drinking, ground and surface water Determination of chemical oxygen demand by permanganate (CODMn) by titration
Regulated area: Tests
SOP-CH 19 (ČSN EN ISO 8467)
13 Drinking and ground water Determination of coliform bacteria and E. coli by membrane filtration
Regulated area: Tests
SOP-B 2 (ČSN EN ISO 9308-1)
14 Drinking, ground and surface water Enumeration of culturable organisms by inoculation into a culture medium at 22 °C and 36 °C
Regulated area: Tests
SOP-B 1 (ČSN EN ISO 6222)
15 Drinking, ground and surface water Determination of intestinal enterococci by membrane filtration
Regulated area: Tests
SOP-B 8 (ČSN EN ISO 7899-2)
16 Waste water Determination of nitrate nitrogen by photometry and of total nitrogen by photometry with a commercial Merck analytical kit
Regulated area: Tests
SOP-CH 31 (ČSN 75 7455; ČSN EN ISO 11905-1; Návod firmy Merck)
17 Waste water Determination of phosphorus by photometry and of total phosphorus by photometry with a commercial Merck analytical kit
Regulated area: Tests
SOP-CH 24 (ČSN EN ISO 6878; Návod firmy Merck)
18 Waste water Determination of chemical oxygen demand CODCr by photometry
Regulated area: Tests
SOP-CH 26 A (ČSN ISO 15705)
19 Drinking, ground, surface and waste water Determination of temperature
Regulated area: Tests
SOP-CH 40 (ČSN 75 7342)
20 Waste water Determination of biochemical oxygen demand (BOD5) by potentiometry
Regulated area: Tests
SOP-CH 30 (ČSN EN ISO 5815-1)
21 Waste water Determination of dissolved solids and dissolved inorganic salts (RAS) by gravimetry
Regulated area: Tests
SOP-CH 32 (ČSN 75 7346; ČSN 75 7347)
22 Waste water Determination of suspended solids and loss on ignition of suspended solids by gravimetry
Regulated area: Tests
SOP-CH 34 (ČSN EN 872; ČSN 75 7350)
23 Drinking, ground and surface water Determination of aluminium by photometry
Regulated area: Tests
SOP-CH 21 (ČSN ISO 10566)
24 Drinking and surface water Determination of Clostridium perfringens by membrane filtration
Regulated area: Tests
SOP-B 5 (ČSN EN ISO 14189)
25 Waste water Determination of chemical oxygen demand (CODCr) by photometry with a commercial HANNA Instruments analytical kit
Regulated area: Tests
SOP CH 26 B (ČSN ISO 15705; Návod firmy HANNA Instruments)
26 Drinking and surface water Biological analysis, determination of the microscopic picture
Regulated area: Tests
SOP-B 4 (ČSN 75 7712; ČSN 75 7713)
27 Drinking, ground, surface and waste water Determination of nitrite by photometry with a discrete analyser
Regulated area: Tests
SOP G 42 (ČSN ISO 15923-1; ČSN EN 26777)
28 Drinking, ground and surface water Determination of iron by photometry with a discrete analyser
Regulated area: Tests
SOP G 42 (ČSN ISO 15923-1; ČSN ISO 6332)
29 Drinking, ground and surface water Determination of aluminium with a discrete analyser by photometry
Regulated area: Tests
SOP G 46 (ČSN ISO 15923-1; ČSN ISO 10566)
30 Drinking and surface water Determination of manganese with a discrete analyser
Regulated area: Tests
SOP G 47 (ČSN ISO 15923-1; US E.P.A. 600/4-79-020)
31 Drinking, raw water Sampling
Regulated area: Sampling
SOP-OST 37 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
32 Waste water Sampling manually and with an automatic sampler
Regulated area: Sampling
SOP-OST 38 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)
Water Treatment Plant
33 Drinking, ground and surface water Determination of turbidity by nephelometry
Regulated area: Tests
SOP-CH 13 (ČSN EN ISO 7027)
34 Drinking, ground, surface and waste water Determination of pH by potentiometry
Regulated area: Tests
SOP-CH 10 (ČSN ISO 10523)
35 Drinking, ground and surface water Determination of total iron by photometry
Regulated area: Tests
SOP-CH 14 (ČSN ISO 6332)
36 Drinking, ground and surface water Determination of chemical oxygen demand by permanganate (CODMn) by titration
Regulated area: Tests
SOP-CH 19 (ČSN EN ISO 8467)
37 Drinking, ground and surface water Determination of aluminium by photometry
Regulated area: Tests
SOP-CH 21 (ČSN ISO 10566)
38 Drinking and surface water Biological analysis, determination of the microscopic picture
Regulated area: Tests
SOP-B 4 (ČSN 75 7712; ČSN 75 7713)

Reference standards (72)

Návod firmy HANNA Instruments
Návod firmy Hach
Návod firmy Merck
SOP CH 26 B
SOP G 42
SOP G 46
SOP G 47
SOP-B 1
SOP-B 2
SOP-B 4
SOP-B 5
SOP-B 8
SOP-CH 10
SOP-CH 11
SOP-CH 12
SOP-CH 13
SOP-CH 14
SOP-CH 15
SOP-CH 16
SOP-CH 17
SOP-CH 18
SOP-CH 19
SOP-CH 21
SOP-CH 24
SOP-CH 26 A
SOP-CH 30
SOP-CH 31
SOP-CH 32
SOP-CH 34
SOP-CH 40
SOP-CH 9
SOP-OST 35
SOP-OST 37
SOP-OST 38
TNV 75 7340
US E.P.A. 600/4-79-020
Vodní hospodářství č. 2 1988
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7350
ČSN 75 7455
ČSN 75 7712
ČSN 75 7713
ČSN EN 1622
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 11905-1
ČSN EN ISO 14189
ČSN EN ISO 19458
ČSN EN ISO 5667-1
ČSN EN ISO 5667-14
ČSN EN ISO 5667-3
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878
ČSN EN ISO 7027
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 15705
ČSN ISO 15923-1
ČSN ISO 5667-10
ČSN ISO 5667-5
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150-1
ČSN ISO 7393-2

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1454