🇨🇿 MORAVSKÁ VODÁRENSKÁ, a.s. PL
Water & wastewaterEnvironmentMicrobiology
MORAVSKÁ VODÁRENSKÁ, a.s. is a laboratory accredited by ČIA under number 1446 (Olomouc, Czech Republic). Its accreditation scope covers 63 test methods in the following areas: Water & wastewater, Environment, Microbiology. Test objects include: Drinking, hot, ground, surface, bottled, bathing water, Water, liquid sludge, Water, Dewatered sludge, liquid sludge. Most frequently used techniques: by spectrophotometry, by gravimetry, Electrometric.
At a glance
- Accreditation number: ČIA 1446
- Methods in scope: 63
- Types of test objects: 13
- Techniques used: 21
- City: Olomouc, Czech Republic
- Valid until: 29-11-2027
- Accreditation number
- 1446
- Accreditation body
- ČIA
- Address
- Dolní Novosadská, 779 00 Olomouc
- City
- Olomouc, Czech Republic
- Division
- Dział Kontroli Jakości Wody
- Valid until
- 29-11-2027
What this laboratory tests (13)
- Drinking, hot, ground, surface, bottled, bathing water — 16 methods
- Water, liquid sludge — 16 methods
- Water — 11 methods
- Dewatered sludge, liquid sludge — 3 methods
- Waste water — 3 methods
- Dewatered sludge — 2 methods
- Drinking, hot, bathing water — 2 methods
- Drinking, hot, ground, surface and waste water, liquid sludge — 2 methods
- Ground water — 2 methods
- Liquid and dewatered sludge, liquid and solid waste, biowaste — 2 methods
- Surface water — 2 methods
- Drinking, raw, process, hot water — 1 method
- Water, liquid and dewatered sludge — 1 method
Analytical techniques used (21)
- by spectrophotometry — 9 methods
- by gravimetry — 5 methods
- Electrometric — 5 methods
- by spectrophotometry using HACH set — 4 methods
- by titration — 4 methods
- by membrane filtration method — 3 methods
- electrochemical probe method — 3 methods
- by coulometry — 2 methods
- by flame AAS — 2 methods
- by flameless AAS — 2 methods
- by spectrophotometry, MERCK set — 2 methods
- optical probe method — 2 methods
- by flame AES — 1 method
- by nephelometry — 1 method
- by titration after distillation — 1 method
- and 6 more
Laboratory sections (2)
- Olomouc Laboratory — 39 methods
- Prostějov Laboratory — 24 methods
Laboratory locations
- Laboratorium Ołomuniec — ČOV Olomouc, Dolní Novosadská
- Laboratorium Prościejów — ČOV Prostějov – Kralický Háj
Certificate information
- Certificate date
- 29.11.2022
Accreditation scope — test methods (63)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Olomouc Laboratory | |||||
| 1 | Water, liquid sludge | Electrometric determination of pH Regulated area: Tests |
Electrometric | S-01A (ČSN ISO 10523) | |
| 2 | Drinking, hot, ground, surface, bottled, bathing water | Determination of ANC 4,5 by titration Regulated area: Tests |
by titration | S-06 (ČSN EN ISO 9963-1) | |
| 3 | Water | Determination of ammonium by spectrophotometry and ammonia nitrogen by calculation ammonia nitrogen by calculation (calculated) Regulated area: Tests |
by spectrophotometry | S-09 (ČSN ISO 7150-1) | |
| 4 | Water | Electrometric determination of conductivity Regulated area: Tests |
Electrometric | S-11 (ČSN EN 27888) | |
| 5 | Drinking, hot, ground, surface, bottled, bathing water | Determination of hardness by titration and magnesium by calculation magnesium by calculation (calculated) Regulated area: Tests |
by titration | S-12A (ČSN ISO 6059) | |
| 6 | Drinking, hot, ground, surface, bottled, bathing water | Determination of calcium by titration Regulated area: Tests |
by titration | S-12B (ČSN ISO 6058) | |
| 7 | Drinking, hot, ground, surface, bottled, bathing water | Determination of COD using permangate by titration Regulated area: Tests |
by titration | S-15 (ČSN EN ISO 8467) | |
| 8 | Drinking, hot, ground, surface, bottled, bathing water | Determination of absorbance by spectrophotometry Regulated area: Tests |
by spectrophotometry | S-17 (ČSN 75 7360) | |
| 9 | Drinking, hot, ground, surface, bottled, bathing water | Determination of turbidity by nephelometry Regulated area: Tests |
by nephelometry | S-20 (návod firmy HACH, ČSN EN ISO 7027-1) | |
| 10 | Drinking, hot, ground, surface, bottled, bathing water | Determination of aluminium by spectrophotometry Regulated area: Tests |
by spectrophotometry | S-27 (ČSN ISO 10566) | |
| 11 | Drinking, hot, bathing water | Determination of free chlorine by spectrophotometry using Hach set Regulated area: Tests |
by spectrophotometry using HACH set | S-28 (návod firmy HACH, ČSN EN ISO 7393-2) | |
| 12 | Water, liquid sludge | Determination of temperature Regulated area: Tests |
S-34 (ČSN 75 7342) | ||
| 13 | Water, liquid sludge | Determination of dissolved oxygen by electrochemical probe method Regulated area: Tests |
electrochemical probe method | S-36A (ČSN EN ISO 5814) | |
| 14 | Water | Determination of dissolved oxygen by optical probe method Regulated area: Tests |
optical probe method | S-36B (ČSN ISO 17289) | |
| 15 | Drinking, hot, ground, surface, bottled, bathing water | Determination of odour and flavour by sensory analysis Regulated area: Tests |
sensory analysis | S-37 (ČSN 75 7340, ČSN EN 1622) | |
| 16 | Drinking, hot, ground, surface, bottled, bathing water | Determination of colour by spectrophotometry Regulated area: Tests |
by spectrophotometry | S-64 (ČSN EN ISO 7887) | |
| 17 | Water, liquid sludge | Determination of metals by flame AAS (Ag, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Zn) Silver (Ag) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Manganese (Mn) Nickel (Ni) Lead (Pb) Zinc (Zn) Regulated area: Tests |
by flame AAS | S-65 mimo kap. 10.1.4. (návod firmy GBC, ČSN ISO 8288, ČSN EN ISO 5961, ČSN EN 1233, ČSN 75 7400, ČSN 75 7385, ČSN EN ISO 15587-1, ČSN EN ISO 15587-2) | |
| 18 | Dewatered sludge, liquid sludge | Determination of metals by flame AAS (Cd, Cr, Cu, Ni, Pb, Zn) Cadmium (Cd) Chromium (Cr) Copper (Cu) Nickel (Ni) Lead (Pb) Zinc (Zn) Regulated area: Tests |
by flame AAS | S-65 mimo kap. 10.1.2., 10.1.3. (návod firmy GBC, ČSN ISO 8288, ČSN EN ISO 5961, ČSN EN 1233, ČSN 46 5735, ČSN EN ISO 15587-1, ČSN EN ISO 15587-2) | |
| 19 | Water, liquid sludge | Determination of metals by flameless AAS (As, Ba, Be, Cd, Co, Cr, Ni, Pb, Sb, Se, V) Arsenic (As) Barium (Ba) Beryllium (Be) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Nickel (Ni) Lead (Pb) Antimony (Sb) Selenium (Se) Vanadium (V) Regulated area: Tests |
by flameless AAS | S-66 mimo kap. 10.1.4. (návod firmy GBC, ČSN EN ISO 15586, ČSN EN ISO 5961, ČSN EN 1233, TNV 75 7408, ČSN EN ISO 15587-1, ČSN EN ISO 15587-2) | |
| 20 | Dewatered sludge, liquid sludge | Determination of metals by flameless AAS (As) Arsenic (As) Regulated area: Tests |
by flameless AAS | S-66 mimo kap. 10.1.2., 10.1.3. (návod firmy GBC, ČSN EN ISO 15586, ČSN 46 5735, ČSN EN ISO 15587-1, ČSN EN ISO 15587-2) | |
| 21 | Water, liquid and dewatered sludge | Determination of mercury by single purpose AAS AMA 254 Regulated area: Tests |
single purpose AAS AMA 254 | S-67 (ČSN 75 7440, ČSN 46 5735, ČSN EN ISO 15587-2) | |
| 22 | Water | Determination of sodium and potassium by flame AES Regulated area: Tests |
by flame AES | S-75 (návod firmy GBC, ČSN ISO 9964-3) | |
| 23 | Water, liquid sludge | Determination of adsorbable organically bound halogens (AOX) by coulometry Regulated area: Tests |
by coulometry | S-76A (ČSN EN ISO 9562) | |
| 24 | Dewatered sludge, liquid sludge | Determination of adsorbable organically bound halogens (AOX) by coulometry Regulated area: Tests |
by coulometry | S-76B (ČSN EN ISO 9562, ČSN EN 16166) | |
| 25 | Drinking, hot, ground, surface, bottled, bathing water | Determination of boron by spectrophotometry Regulated area: Tests |
by spectrophotometry | S-77 (ČSN ISO 9390) | |
| 26 | Drinking, hot, ground, surface, bottled, bathing water | Determination of humic substances by spectrophotometry Regulated area: Tests |
by spectrophotometry | S-79 (ČSN 75 7536) | |
| 27 | Water | Determination of total cyanide by spectrophotometry Regulated area: Tests |
by spectrophotometry | S-87 (ČSN 75 7415, návod firmy MERCK) | |
| 28 | Water | Determination of hydrocarbons C10 - C40 by gas chromatography (FID) Regulated area: Tests |
gas chromatography (FID) | S-112 (ČSN EN ISO 9377-2) | |
| 29 | Water | Determination of anions by ion chromatography (conductivity detection) bromates nitrates nitrites fluorides phosphates chlorates chlorides chlorites sulphates nitrate nitrogen, nitrite nitrogen, phosphate phosphorus, sum of chlorates and chlorites by calculation (calculated) Regulated area: Tests |
ion chromatography (conductivity detection) | S-115 (ČSN EN ISO 10304-1, ČSN EN ISO 10304-4, ČSN EN ISO 15061) | |
| 30 | Drinking, hot, ground, surface, bottled, bathing water | Detection and enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration method Regulated area: Tests |
by membrane filtration method | S-24 (ČSN 75 7835) | |
| 31 | Drinking, hot, ground, surface, bottled, bathing water | Detection and enumeration of intestinal enterococci by membrane filtration method Regulated area: Tests |
by membrane filtration method | S-25 (ČSN EN ISO 7899-2) | |
| 32 | Drinking, hot, ground, surface, bottled, bathing water | Enumeration of culturable microorganisms at 22 °C and 36 °C by direct inoculation method Regulated area: Tests |
direct inoculation method | S-39 (ČSN EN ISO 6222) | |
| 33 | Drinking, hot, ground, surface, bottled, bathing water | Enumeration of coliform bacteria and Escherichia coli by membrane filtration method Regulated area: Tests |
by membrane filtration method | S-116 (ČSN EN ISO 9308-1) | |
| 34 | Drinking, hot, ground, surface, bottled, bathing water | Detection and enumeration of coliform bacteria and Escherichia coli by most probable number method Regulated area: Tests |
most probable number method | S-120 (ČSN EN ISO 9308-2) | |
| 35 | Drinking, raw, process, hot water | Drinking water sampling Regulated area: Sampling |
S-301 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-5, ČSN EN ISO 5667-14, ČSN ISO 5667-21, ČSN EN ISO 19458) | ||
| 36 | Ground water | Sampling of ground water (static, dynamic) Regulated area: Sampling |
S-302 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-11, ČSN EN ISO 5667-14, ČSN EN ISO 19458) | ||
| 37 | Surface water | Sampling of surface water Regulated area: Sampling |
S-303 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-4, ČSN EN ISO 5667-6, ČSN EN ISO 5667-14, ČSN EN ISO 19458) | ||
| 38 | Waste water | Sampling of waste water (manual sampling and sampling using an automatic sampler) Regulated area: Sampling |
S-304 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-10, ČSN EN ISO 5667-14, ČSN EN ISO 19458) | ||
| 39 | Liquid and dewatered sludge, liquid and solid waste, biowaste | Sampling of sludge and waste Regulated area: Sampling |
S-305 (ČSN EN 14899, ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN EN ISO 5667-13, ČSN EN ISO 5667-14, ČSN EN ISO 5667-15, ČSN EN ISO 19458) | ||
| Prostějov Laboratory | |||||
| 40 | Water, liquid sludge | Electrometric determination of pH Regulated area: Tests |
Electrometric | S-01A (ČSN ISO 10523) | |
| 41 | Dewatered sludge | Electrometric determination of pH Regulated area: Tests |
Electrometric | S-01B (ČSN ISO 10523, ČSN EN 15933) | |
| 42 | Water | Determination of ammonium by spectrophotometry and ammonia nitrogen by calculation ammonia nitrogen by calculation (calculated) Regulated area: Tests |
by spectrophotometry | S-09 (ČSN ISO 7150-1) | |
| 43 | Water | Electrometric determination of conductivity Regulated area: Tests |
Electrometric | S-11 (ČSN EN 27888) | |
| 44 | Water, liquid sludge | Determination of dissolved solids, dissolved inorganic salts by gravimetry and loss on ignition of dissolved solids by calculation loss on ignition of dissolved solids by calculation (calculated) Regulated area: Tests |
by gravimetry | S-19 (ČSN 75 7346, ČSN 75 7347) | |
| 45 | Drinking, hot, bathing water | Determination of free chlorine by spectrophotometry using Hach set Regulated area: Tests |
by spectrophotometry using HACH set | S-28 (návod firmy HACH, ČSN EN ISO 7393-2) | |
| 46 | Water, liquid sludge | Determination of temperature Regulated area: Tests |
S-34 (ČSN 75 7342) | ||
| 47 | Water, liquid sludge | Determination of dissolved oxygen by electrochemical probe method Regulated area: Tests |
electrochemical probe method | S-36A (ČSN EN ISO 5814) | |
| 48 | Water | Determination of dissolved oxygen by optical probe method Regulated area: Tests |
optical probe method | S-36B (ČSN ISO 17289) | |
| 49 | Drinking, hot, ground, surface and waste water, liquid sludge | Determination of ammonia nitrogen by titration after distillation, ammonium and inorganic nitrogen by calculation ammonium and inorganic nitrogen by calculation (calculated) Regulated area: Tests |
by titration after distillation | S-43 (ČSN ISO 5664) | |
| 50 | Drinking, hot, ground, surface and waste water, liquid sludge | Determination of total nitrogen by spectrophotometry and organic nitrogen by calculation organic nitrogen by calculation (calculated) Regulated area: Tests |
by spectrophotometry | S-45 (návod firmy MERCK, ČSN 75 7455) | |
| 51 | Water, liquid sludge | Determination of phosphate by spectrophotometry and phosphate phosphorus by calculation MERCK set phosphate phosphorus by calculation (calculated) Regulated area: Tests |
by spectrophotometry, MERCK set | S-46 (návod firmy MERCK, ČSN EN ISO 6878) | |
| 52 | Water, liquid sludge | Determination of total phosphorus by spectrophotometry MERCK set Regulated area: Tests |
by spectrophotometry, MERCK set | S-47 (návod firmy MERCK, ČSN EN ISO 6878) | |
| 53 | Water | Determination of anionic surfactants by spectrophotometry using HACH set Regulated area: Tests |
by spectrophotometry using HACH set | S-48 (návod firmy HACH, ČSN EN 903) | |
| 54 | Water, liquid sludge | Determination of biochemical oxygen demand after n days (BODn) by electrochemical probe method Regulated area: Tests |
electrochemical probe method | S-50 (ČSN EN ISO 5815-1, ČSN EN 1899-2, ČSN EN ISO 5814) | |
| 55 | Water, liquid sludge | Determination of suspended solids and loss on ignition of suspended solids by gravimetry Regulated area: Tests |
by gravimetry | S-52 (ČSN EN 872, ČSN 75 7350) | |
| 56 | Water, liquid sludge | Determination of total solids and loss on ignition of total solids by gravimetry Regulated area: Tests |
by gravimetry | S-53A (ČSN EN 12880) | |
| 57 | Dewatered sludge | Determination of total solids and loss on ignition of total solids by gravimetry Regulated area: Tests |
by gravimetry | S-53B (ČSN EN 12880) | |
| 58 | Waste water | Determination of fats and oils by gravimetry Regulated area: Tests |
by gravimetry | S-54 (ČSN 75 7509) | |
| 59 | Water, liquid sludge | Determination of COD with dichromate by spectrophotometry using HACH set Regulated area: Tests |
by spectrophotometry using HACH set | S-117 (návod firmy HACH, ČSN ISO 15705) | |
| 60 | Ground water | Sampling of ground water (static, dynamic) Regulated area: Sampling |
S-302 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-11, ČSN EN ISO 5667-14, ČSN EN ISO 19458) | ||
| 61 | Surface water | Sampling of surface water Regulated area: Sampling |
S-303 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-4, ČSN EN ISO 5667-6, ČSN EN ISO 5667-14, ČSN EN ISO 19458) | ||
| 62 | Waste water | Sampling of waste water (manual sampling and sampling using an automatic sampler) Regulated area: Sampling |
S-304 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-10, ČSN EN ISO 5667-14, ČSN EN ISO 19458) | ||
| 63 | Liquid and dewatered sludge, liquid and solid waste, biowaste | Sampling of sludge and waste Regulated area: Sampling |
S-305 (ČSN EN 14899, ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN EN ISO 5667-13, ČSN EN ISO 5667-14, ČSN EN ISO 5667-15, ČSN EN ISO 19458) | ||
Reference standards (125)
S-01A
S-01B
S-06
S-09
S-11
S-112
S-115
S-116
S-117
S-120
S-12A
S-12B
S-15
S-17
S-19
S-20
S-24
S-25
S-27
S-28
S-301
S-302
S-303
S-304
S-305
S-34
S-36A
S-36B
S-37
S-39
S-43
S-45
S-46
S-47
S-48
S-50
S-52
S-53A
S-53B
S-54
S-64
S-65 mimo kap. 10.1.2., 10.1.3.
S-65 mimo kap. 10.1.4.
S-66 mimo kap. 10.1.2., 10.1.3.
S-66 mimo kap. 10.1.4.
S-67
S-75
S-76A
S-76B
S-77
S-79
S-87
TNV 75 7408
návod firmy GBC
návod firmy HACH
návod firmy MERCK
ČSN 46 5735
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7350
ČSN 75 7360
ČSN 75 7385
ČSN 75 7400
ČSN 75 7415
ČSN 75 7440
ČSN 75 7455
ČSN 75 7509
ČSN 75 7536
ČSN 75 7835
ČSN EN 1233
ČSN EN 12880
ČSN EN 14899
ČSN EN 15933
ČSN EN 16166
ČSN EN 1622
ČSN EN 1899-2
ČSN EN 27888
ČSN EN 872
ČSN EN 903
ČSN EN ISO 10304-1
ČSN EN ISO 10304-4
ČSN EN ISO 15061
ČSN EN ISO 15586
ČSN EN ISO 15587-1
ČSN EN ISO 15587-2
ČSN EN ISO 19458
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5814
ČSN EN ISO 5815-1
ČSN EN ISO 5961
ČSN EN ISO 6222
ČSN EN ISO 6878
ČSN EN ISO 7027-1
ČSN EN ISO 7393-2
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9308-2
ČSN EN ISO 9377-2
ČSN EN ISO 9562
ČSN EN ISO 9963-1
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 15705
ČSN ISO 17289
ČSN ISO 5664
ČSN ISO 5667-10
ČSN ISO 5667-11
ČSN ISO 5667-21
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 7150-1
ČSN ISO 8288
ČSN ISO 9390
ČSN ISO 9964-3