🇨🇿 CHEVAK Cheb, a.s. PL

ČIA 1442 • Cheb, Czech Republic • 53 methods

Water & wastewaterMicrobiologyEnvironment

CHEVAK Cheb, a.s. is a laboratory accredited by ČIA under number 1442 (Cheb, Czech Republic). Its accreditation scope covers 53 test methods in the following areas: Water & wastewater, Microbiology, Environment. Test objects include: Drinking, surface and ground water, Drinking, surface, ground and waste water, Sludge, Surface and waste water.

At a glance

  • Accreditation number: ČIA 1442
  • Methods in scope: 53
  • Types of test objects: 11
  • City: Cheb, Czech Republic
  • Valid until: 26-10-2027
Accreditation number
1442
Accreditation body
ČIA
Address
Tršnická 4/11, Hradiště, 350 02 Cheb
City
Cheb, Czech Republic
Division
Laboratorium Centralne CHEVAK Cheb, a.s.
Valid until
26-10-2027

What this laboratory tests (11)

Certificate information

Certificate date
17.04.2026

Accreditation scope — test methods (53)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Drinking, surface and ground water Determination of manganese by spectrophotometry
Regulated area: Tests
SOP č.5-PV/02 (ČSN ISO 6333)
2 Drinking, surface and ground water Determination of total iron by spectrophotometry with 1,10-phenanthroline
Regulated area: Tests
SOP č.6-PV/02 (ČSN ISO 6332)
3 Drinking, surface and ground water Determination of dissolved fluorides by spectrophotometry
Regulated area: Tests
SOP č.7-PV/02 (TNV 75 7431)
4 Drinking, surface and ground water Determination of aluminium by spectrophotometry
Regulated area: Tests
SOP č.8-PV/02 (ČSN ISO 10566)
5 Drinking, surface and ground water Determination of pH by potentiometry
Regulated area: Tests
SOP č.9-PV/02 (ČSN ISO 10523)
6 Drinking, surface and ground water Determination of chemical oxygen demand by permanganate (CODMn) by titration
Regulated area: Tests
SOP č.11-PV/02 (ČSN EN ISO 8467)
7 Drinking, surface and ground water Determination of absorbance at a wavelength of 254 nm by spectrophotometry
Regulated area: Tests
SOP č.17-PV/02 (ČSN 75 7360)
8 Drinking, surface and ground water Determination of electrical conductivity
Regulated area: Tests
SOP č.18-PV/02 (ČSN EN 27888)
9 Drinking, surface and ground water Determination of colour by photometry
Regulated area: Tests
SOP č.19-PV/O4 (ČSN EN ISO 7887 - metoda B)
10 Drinking water Determination of free chlorine by spectrophotometry using a HACH kit
Regulated area: Tests
SOP č.20-PV/04 (ČSN EN ISO 7393-2, návod firmy HACH)
11 Drinking, surface and ground water Determination of turbidity by nephelometry
Regulated area: Tests
SOP č.22-PV/19 (ČSN EN ISO 7027-1, kapitola 5.3)
12 Drinking, surface, ground and waste water Determination of dissolved oxygen by electrochemical method
Regulated area: Tests
SOP č.23-PV/05 (ČSN EN ISO 5814)
13 Drinking, surface, ground and waste water Determination of temperature
Regulated area: Tests
SOP č.29-L/12 (ČSN 75 7342)
14 Drinking, surface and ground water Determination of base neutralising capacity (BNC8.3) by acid-base titration
Regulated area: Tests
SOP č.28-PV/12 (ČSN 75 7372)
15 Drinking, surface and ground water Enumeration of culturable micro-organisms by inoculation in a nutrient agar culture medium
Regulated area: Tests
SOP č.3-BA/12 (ČSN EN ISO 6222)
16 Surface and ground water Determination of thermotolerant coliform bacteria and Escherichia coli by the membrane filtration method
Regulated area: Tests
SOP č.4-BA/12 (ČSN 75 7835)
17 Drinking water Determination of Escherichia coli and coliform bacteria by the membrane filtration method
Regulated area: Tests
SOP č.5-BA/15 (ČSN EN ISO 9308-1)
18 Drinking, surface and ground water Determination of Clostridium perfringens by the membrane filtration method
Regulated area: Tests
SOP č.11-BA/22 (ČSN EN ISO 14189)
19 Drinking, surface and ground water Determination of intestinal enterococci by the membrane filtration method
Regulated area: Tests
SOP č.7-BA/12 (ČSN EN ISO 7899-2)
20 Surface and ground water Determination of coliform bacteria in non-disinfected water by the membrane filtration method
Regulated area: Tests
SOP č.8-BA/12 (ČSN 75 7837)
21 Drinking, surface and ground water Determination of abioseston by microscopy
Regulated area: Tests
SOP č.10-Bi/12 (ČSN 75 7713)
22 Drinking, surface and ground water Determination of bioseston by microscopy
Regulated area: Tests
SOP č.9-Bi/12 (ČSN 75 7712)
23 Surface and waste water Determination of suspended solids at 105°C by gravimetry
Regulated area: Tests
SOP č.5-OV/02 (ČSN EN 872)
24 Surface and waste water Determination of dissolved solids dried at 105°C (RL) and ignited at 550°C (dissolved inorganic salts, RAS) by gravimetry
dissolved solids dried at 105°C (RL) dissolved inorganic salts (RAS)
Regulated area: Tests
SOP č.6-OV/02 (ČSN 75 7346; ČSN 75 7347)
25 Surface and waste water Determination of biochemical oxygen demand after five days (BOD5) by the dilution and seeding method with an optical probe
Regulated area: Tests
SOP č.7-OV/18 - část A (ČSN EN ISO 5815-1)
26 Drinking, surface and ground water Determination of biochemical oxygen demand after five days (BOD5) by the method for undiluted samples, electrochemically
Regulated area: Tests
SOP č.7-OV/18 - část B (ČSN EN 1899-2)
27 Surface and waste water Determination of pH by potentiometry
Regulated area: Tests
SOP č.11-OV/05 (ČSN ISO 10523)
28 Sludge Determination of dry matter and residue on ignition by gravimetry, water content and loss on ignition by calculation from measured values
dry matter residue on ignition
water content (calculated), loss on ignition (calculated)
Regulated area: Tests
SOP č.15-OV/18 - část I (ČSN EN 15934 – metoda A; ČSN EN 15935)
29 Sludge Determination of Kjeldahl nitrogen by titration after mineralisation with selenium and total nitrogen by calculation from measured values
Kjeldahl nitrogen
total nitrogen (calculated)
Regulated area: Tests
SOP č.15-OV/18 - část III (ČSN EN 16169)
30 Sludge Determination of pH by potentiometry
Regulated area: Tests
SOP č.15-OV/18 - část IV (ČSN EN ISO 10390)
31 Drinking water Indicative sensory analysis – determination of odour and taste
Regulated area: Tests
SOP č.24-PV/19 (ČSN 75 7340, kapitola 8 a 9)
32 Drinking, surface, ground and waste water Determination of mercury by atomic absorption (AMA)
Regulated area: Tests
SOP č.7-AAS/09 - část A (ČSN 75 7440)
33 Sludge Determination of mercury by atomic absorption (AMA)
Regulated area: Tests
SOP č.7-AAS/09 - část B (ČSN 75 7440)
34 Drinking, surface and ground water Determination of boron by spectrophotometry
Regulated area: Tests
SOP č.25-PV/09 (ČSN ISO 9390)
35 Drinking, surface, ground and waste water Determination of adsorbable organically bound halogens (AOX) by microcoulometric titration
Regulated area: Tests
SOP č.8-AAS/16 - část A (ČSN EN ISO 9562)
36 Sludge Determination of adsorbable organically bound halogens (AOX) by microcoulometric titration
Regulated area: Tests
SOP č.8-AAS/16 - část B (ČSN EN 16166)
37 Drinking and raw water Determination of threshold odour number (TON) and threshold flavour number (TFN)
Regulated area: Tests
SOP č. 29-PV/19 (ČSN EN 1622)
38 Drinking, surface, ground and waste water Determination of ammonium ions by discrete photometry and ammonium nitrogen by calculation from measured values
ammonium ions
ammonium nitrogen (calculated)
Regulated area: Tests
SOP č.1-G/19 (ČSN EN ISO 15923-1; Aplikační list metody fy Thermo Scientific)
39 Drinking, surface, ground and waste water Determination of nitrites by discrete photometry and nitrite nitrogen by calculation from measured values
nitrites
nitrite nitrogen (calculated)
Regulated area: Tests
SOP č.2-G/19 (ČSN EN ISO 15923-1; Aplikační list metody fy Thermo Scientific)
40 Drinking, surface, ground and waste water Determination of the sum of nitrates and nitrites after reduction with hydrazine by discrete photometry and of nitrates, nitrate nitrogen and inorganic nitrogen by calculation from measured values
sum of nitrates and nitrites
nitrates (calculated), nitrate nitrogen (calculated), inorganic nitrogen (calculated)
Regulated area: Tests
SOP č. 3-G/19 (ČSN EN ISO 15923-1; Aplikační list metody fy Thermo Scientific)
41 Drinking, surface, ground and waste water Determination of acid neutralising capacity (ANC4.5) by discrete photometry
Regulated area: Tests
SOP č. 4-G/19 (Aplikační list metody fy Thermo Scientific)
42 Drinking, surface, ground and waste water Determination of chlorides by discrete photometry
Regulated area: Tests
SOP č. 5-G/19 (ČSN EN ISO 15923-1; Aplikační list metody fy Thermo Scientific)
43 Drinking, surface, ground and waste water Determination of sulphates by nephelometrically measured turbidity by discrete photometry
Regulated area: Tests
SOP č. 6-G/19 (ČSN EN ISO 15923-1; Aplikační list metody fy Thermo Scientific)
44 Drinking, surface, ground and waste water Determination of orthophosphates by discrete photometry and orthophosphate phosphorus by calculation from measured values
orthophosphates
orthophosphate phosphorus (calculated)
Regulated area: Tests
SOP č. 7-G/19 (ČSN EN ISO 15923-1; Aplikační list metody fy Thermo Scientific)
45 Drinking, surface and ground water Determination of calcium and magnesium by discrete photometry and total hardness by calculation from measured values
calcium magnesium
total hardness (calculated)
Regulated area: Tests
SOP č. 8-G/19 (Aplikační listy metody fy Thermo Scientific)
46 Surface, ground and waste water Determination of CODCr by spectrophotometry using the sealed-tube method with a Hach cuvette test
Regulated area: Tests
SOP č. 1-H/20 (ČSN ISO 15705; Aplikační list firmy HACH pro sady LCI 400 a LCI 500)
47 Surface, ground and waste water Determination of total phosphorus by spectrophotometry using a Hach cuvette test
Regulated area: Tests
SOP č. 2-H/20 (Aplikační list firmy HACH pro sady LCK 349 a LCK 350)
48 Surface, ground and waste water Determination of total nitrogen by spectrophotometry using a Hach cuvette test and organic nitrogen by calculation from measured values
total nitrogen
organic nitrogen (calculated)
Regulated area: Tests
SOP č. 3-H/20 (Aplikační list firmy HACH pro sady LCK 338 a LCK 138)
49 Surface, ground and waste water Determination of anionic surfactants by spectrophotometry using a Hach cuvette test
Regulated area: Tests
SOP č. 4-H/20 (Aplikační list firmy HACH pro sady LCK 332 a LCK 432)
50 Drinking and ground water Sampling of drinking water and water intended for treatment into drinking water
Regulated area: Sampling
SOP odběr č. 1-L/04 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN ISO 5667-21; ČSN EN ISO 19458; Vyhláška 252/2004 Sb.)
51 Surface water Sampling from watercourses and water reservoirs
Regulated area: Sampling
SOP odběr č. 2-L/04 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4, kap. 12; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
52 Waste water Sampling of waste water (manual sampling)
Regulated area: Sampling
SOP odběr č. 3-L/04 - část A (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
53 Waste water Sampling of waste water (by automatic sampling device)
Regulated area: Sampling
SOP odběr č. 3-L/04 - část B (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)

Reference standards (111)

Aplikační list firmy HACH pro sady LCI 400 a LCI 500
Aplikační list firmy HACH pro sady LCK 332 a LCK 432
Aplikační list firmy HACH pro sady LCK 338 a LCK 138
Aplikační list firmy HACH pro sady LCK 349 a LCK 350
Aplikační list metody fy Thermo Scientific
Aplikační listy metody fy Thermo Scientific
SOP odběr č. 1-L/04
SOP odběr č. 2-L/04
SOP odběr č. 3-L/04 - část A
SOP odběr č. 3-L/04 - část B
SOP č. 1-H/20
SOP č. 2-H/20
SOP č. 29-PV/19
SOP č. 3-G/19
SOP č. 3-H/20
SOP č. 4-G/19
SOP č. 4-H/20
SOP č. 5-G/19
SOP č. 6-G/19
SOP č. 7-G/19
SOP č. 8-G/19
SOP č.1-G/19
SOP č.10-Bi/12
SOP č.11-BA/22
SOP č.11-OV/05
SOP č.11-PV/02
SOP č.15-OV/18 - část I
SOP č.15-OV/18 - část III
SOP č.15-OV/18 - část IV
SOP č.17-PV/02
SOP č.18-PV/02
SOP č.19-PV/O4
SOP č.2-G/19
SOP č.20-PV/04
SOP č.22-PV/19
SOP č.23-PV/05
SOP č.24-PV/19
SOP č.25-PV/09
SOP č.28-PV/12
SOP č.29-L/12
SOP č.3-BA/12
SOP č.4-BA/12
SOP č.5-BA/15
SOP č.5-OV/02
SOP č.5-PV/02
SOP č.6-OV/02
SOP č.6-PV/02
SOP č.7-AAS/09 - část A
SOP č.7-AAS/09 - část B
SOP č.7-BA/12
SOP č.7-OV/18 - část A
SOP č.7-OV/18 - část B
SOP č.7-PV/02
SOP č.8-AAS/16 - část A
SOP č.8-AAS/16 - část B
SOP č.8-BA/12
SOP č.8-PV/02
SOP č.9-Bi/12
SOP č.9-PV/02
TNV 75 7431
Vyhláška 252/2004 Sb.
návod firmy HACH
ČSN 75 7315
ČSN 75 7340, kapitola 8 a 9
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7360
ČSN 75 7372
ČSN 75 7440
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN 75 7837
ČSN EN 15934 – metoda A
ČSN EN 15935
ČSN EN 16166
ČSN EN 16169
ČSN EN 1622
ČSN EN 1899-2
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 10390
ČSN EN ISO 14189
ČSN EN ISO 15923-1
ČSN EN ISO 19458
ČSN EN ISO 5667-1
ČSN EN ISO 5667-14
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5814
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 7027-1, kapitola 5.3
ČSN EN ISO 7393-2
ČSN EN ISO 7887 - metoda B
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9562
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 15705
ČSN ISO 5667-10
ČSN ISO 5667-11
ČSN ISO 5667-21
ČSN ISO 5667-4, kap. 12
ČSN ISO 5667-5
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 9390

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1442