🇨🇿 Vodovody a kanalizace Vsetín, a.s. PL

ČIA 1441 • Vsetín, Czech Republic • 61 methods

Water & wastewaterMicrobiology

Vodovody a kanalizace Vsetín, a.s. is a laboratory accredited by ČIA under number 1441 (Vsetín, Czech Republic). Its accreditation scope covers 61 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Waters, Drinking, ground, raw, surface water, Drinking, raw, ground, surface water, Waters, sludge.

At a glance

  • Accreditation number: ČIA 1441
  • Methods in scope: 61
  • Types of test objects: 15
  • City: Vsetín, Czech Republic
  • Valid until: 03-11-2027
Accreditation number
1441
Accreditation body
ČIA
Address
Jiráskova 1089, 755 01 Vsetín
City
Vsetín, Czech Republic
Division
Laboratorium Centralne
Valid until
03-11-2027

What this laboratory tests (15)

Laboratory sections (3)

Laboratory locations

Certificate information

Certificate date
23.06.2025

Accreditation scope — test methods (61)

No. Test object Methodology / Parameters Technique Reference document
Vsetín site
1 Waters Determination of ammonium ions by spectrophotometry and of ammonium nitrogen and inorganic nitrogen by calculation from measured values
Regulated area: Chemical tests
SOP 01 (ČSN ISO 7150‒1)
2 Waters Determination of nitrite by spectrophotometry and of nitrite nitrogen by calculation from measured values
Regulated area: Chemical tests
SOP 02 (ČSN EN 26777)
3 Waters Determination of nitrate by spectrophotometry
Regulated area: Chemical tests
SOP 03 (ČSN ISO 7890‒3)
4 Waters Determination of chloride by titration
Regulated area: Chemical tests
SOP 04 (ČSN ISO 9297)
5 Waters Determination of total iron by spectrophotometry with o-phenanthroline
Regulated area: Chemical tests
SOP 05 (ČSN ISO 6332)
6 Drinking, raw, ground, surface water Determination of manganese by spectrophotometry
Regulated area: Chemical tests
SOP 06 (ČSN ISO 6333)
7 Drinking, raw, ground, surface water Determination of aluminium by spectrophotometry
Regulated area: Chemical tests
SOP 07 (ČSN ISO 10566)
8 Drinking, raw, ground, surface water Determination of calcium by titration
Regulated area: Chemical tests
SOP 08 (ČSN ISO 6058)
9 Drinking, raw, ground, surface water Determination of the sum of calcium and magnesium by titration and calculation of magnesium from measured values
Regulated area: Chemical tests
SOP 08 A (ČSN ISO 6059)
10 Waters Determination of temperature
Regulated area: Chemical tests
SOP 10 (ČSN 75 7342)
11 Waters Determination of pH by potentiometry
Regulated area: Chemical tests
SOP 11 (ČSN ISO 10523)
12 Waters Determination of electrical conductivity
Regulated area: Chemical tests
SOP 12 (ČSN EN 27888)
13 Drinking, raw, hot, ground, surface water Determination of turbidity by turbidimetry
Regulated area: Chemical tests
SOP 13 (ČSN EN ISO 7027-1)
14 Waters Determination of acid neutralizing capacity by titration
Regulated area: Chemical tests
SOP 14 (ČSN EN ISO 9963‒1)
15 Drinking, raw, hot, ground water Determination of odour and taste by indicative sensory analysis
Regulated area: Chemical tests
SOP 15 (ČSN EN 1622; ČSN 75 7340)
16 Waters Determination of chemical oxygen demand by permanganate by titration
Regulated area: Chemical tests
SOP 16 (ČSN EN ISO 8467)
17 Waters Determination of chemical oxygen demand by dichromate by spectrophotometry with a HACH kit
Regulated area: Chemical tests
SOP 17 (ČSN ISO 15705; Návod firmy HACH)
18 Waters, sludge Determination of suspended solids by gravimetry
Regulated area: Chemical tests
SOP 18 (ČSN EN 872)
19 Waters, sludge Determination of dissolved solids, dissolved inorganic salts and total solids by gravimetry
Regulated area: Chemical tests
SOP 19 (ČSN 75 7346; ČSN 75 7347)
20 Waters Determination of total phosphorus by spectrophotometry with a HACH kit and of phosphates by calculation from measured values
Regulated area: Chemical tests
SOP 20 (ČSN EN ISO 6878; Návod firmy HACH)
21 Waters Determination of fluoride by spectrophotometry
Regulated area: Chemical tests
SOP 21 (TNV 75 7431)
22 Waters Determination of anionic surfactants by spectrophotometry
Regulated area: Chemical tests
SOP 22 (ČSN EN 903)
23 Waters Determination of sulphates by titration
Regulated area: Chemical tests
SOP 23 (ČSN 75 7477)
24 Drinking water, hot water Determination of free and total chlorine by photometry
Regulated area: Chemical tests
SOP 24 (ČSN EN ISO 7393‒2)
25 Waters Determination of nitrate nitrogen by spectrophotometry with a HACH kit
Regulated area: Chemical tests
SOP 36 (ČSN ISO 23696-1; Návod firmy HACH)
26 Drinking, raw, hot, ground, surface water Determination of colour by photometry
Regulated area: Chemical tests
SOP 42 (ČSN EN ISO 7887)
27 Waters Determination of total nitrogen by spectrophotometry with a HACH kit
Regulated area: Chemical tests
SOP 45 (ČSN ISO 23697-1; Návod firmy HACH)
28 Waters Determination of biochemical oxygen demand after 5 days (BOD5) by iodometry
Regulated area: Chemical tests
SOP 46 (ČSN EN ISO 5815-1; ČSN EN 1899‒2; ČSN EN 25813)
29 Waters Determination of biochemical oxygen demand after 5 days (BOD5) with an oximeter
Regulated area: Chemical tests
SOP 46 A (ČSN EN ISO 5815-1; ČSN EN 1899‒2; ČSN EN ISO 5814)
30 Drinking, raw, hot, ground, surface water Determination of turbidity by nephelometry
Regulated area: Chemical tests
SOP 13 A (ČSN EN ISO 7027-1)
31 Waters Determination of total cyanides (after distillation) by photometry
Regulated area: Chemical tests
SOP 47 (ČSN 75 741)
32 Waters Determination of biochemical oxygen demand after 5 days (BOD5) with an oximeter
Regulated area: Chemical tests
SOP 46 B (ČSN EN ISO 5815-1; ČSN EN 1899‒2; ČSN EN ISO 17289)
33 Waters Determination of adsorbable organically bound halogens (AOX) by coulometry
Regulated area: Chemical tests
SOP 49 (ČSN EN ISO 9562; TNI 75 7531)
34 Surface water Sampling of surface water from rivers, streams and reservoirs manually and with an automatic sampler
Regulated area: Sampling
SPP 01 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN ISO 5667‒4; ČSN EN ISO 5667‒6; ČSN EN ISO 5667‒14; ČSN EN ISO 19458)
35 Drinking water Sampling of drinking water
Regulated area: Sampling
SPP 02 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN ISO 5667-5; ČSN EN ISO 5667‒14; ČSN EN ISO 19458)
36 Sludge Sampling of sludge
Regulated area: Sampling
SPP 03 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN EN ISO 5667‒13; ČSN EN ISO 5667‒14; ČSN EN ISO 5667‒15)
37 Waste water Sampling of waste water manually and with an automatic sampler
Regulated area: Sampling
SPP 04 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN ISO 5667‒10; ČSN EN ISO 5667‒14)
38 Ground water Sampling of ground water manually and with a pump (static sampling)
Regulated area: Sampling
SPP 05 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN ISO 5667‒11; ČSN EN ISO 5667‒14)
Valašské Meziříčí site
39 Waters Determination of ammonium ions by spectrophotometry and of ammonium nitrogen and inorganic nitrogen by calculation from measured values
Regulated area: Chemical tests
SOP 01 (ČSN ISO 7150‒1)
40 Waters Determination of nitrite by spectrophotometry and of nitrite nitrogen by calculation from measured values
Regulated area: Chemical tests
SOP 02 (ČSN EN 26777)
41 Waters Determination of pH by potentiometry
Regulated area: Chemical tests
SOP 11 (ČSN ISO 10523)
42 Waters Determination of chemical oxygen demand by dichromate by spectrophotometry with a HACH kit
Regulated area: Chemical tests
SOP 17 (ČSN ISO 15705; Návod firmy HACH)
43 Waters, sludge Determination of suspended solids by gravimetry
Regulated area: Chemical tests
SOP 18 (ČSN EN 872)
44 Waters, sludge Determination of dissolved solids, dissolved inorganic salts and total solids by gravimetry
Regulated area: Chemical tests
SOP 19 (ČSN 75 7346; ČSN 75 7347)
45 Waters Determination of total phosphorus by spectrophotometry with a HACH kit and of phosphates by calculation from measured values
Regulated area: Chemical tests
SOP 20 (ČSN EN ISO 6878; Návod firmy HACH)
46 Waters Determination of nitrate nitrogen by spectrophotometry with a HACH kit
Regulated area: Chemical tests
SOP 36 (ČSN ISO 23696-1; Návod firmy HACH)
47 Waters Determination of total nitrogen by spectrophotometry with a HACH kit
Regulated area: Chemical tests
SOP 45 (ČSN ISO 23697-1; Návod firmy HACH)
48 Waters Determination of biochemical oxygen demand after 5 days (BOD5) by iodometry
Regulated area: Chemical tests
SOP 46 (ČSN EN ISO 5815-1; ČSN EN 1899‒2; ČSN EN 25813)
49 Surface water Sampling of surface water from rivers, streams and reservoirs manually and with an automatic sampler
Regulated area: Sampling
SPP 01 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN ISO 5667‒4; ČSN EN ISO 5667‒6; ČSN EN ISO 5667‒14; ČSN EN ISO 19458)
50 Sludge Sampling of sludge
Regulated area: Sampling
SPP 03 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN EN ISO 5667‒13; ČSN EN ISO 5667‒14; ČSN EN ISO 5667‒15)
51 Waste water Sampling of waste water manually and with an automatic sampler
Regulated area: Sampling
SPP 04 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN ISO 5667‒10; ČSN EN ISO 5667‒14)
52 Ground water Sampling of ground water manually and with a pump (static sampling)
Regulated area: Sampling
SPP 05 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN ISO 5667‒11; ČSN EN ISO 5667‒14)
Karolinka site
53 Drinking, ground, raw, surface water Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Microbiological tests
SOP 25 (ČSN 75 7835)
54 Drinking, hot, ground water Determination of coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Microbiological tests
SOP 26 (ČSN EN ISO 9308‒1)
55 Drinking, ground, raw, surface water Determination of intestinal enterococci by membrane filtration
Regulated area: Microbiological tests
SOP 27 (ČSN EN ISO 7899‒2)
56 Drinking, ground, raw, surface water Determination of bioseston by microscopy
Regulated area: Microbiological tests
SOP 30 (ČSN 75 7712)
57 Drinking, ground, raw, surface water Determination of abioseston by microscopy
Regulated area: Microbiological tests
SOP 31 (ČSN 75 7713)
58 Drinking, ground, raw, surface water Determination of Clostridium perfringens by membrane filtration
Regulated area: Microbiological tests
SOP 38 (Příloha č. 6 vyhl. 252/2004 Sb.)
59 Drinking, hot, ground, raw, surface water Enumeration of culturable microorganisms at 22 °C and 36 °C by direct plating
Regulated area: Microbiological tests
SOP 39 (ČSN EN ISO 6222)
60 Non-disinfected, raw, surface water Determination of coliform bacteria by membrane filtration
Regulated area: Microbiological tests
SOP 40 (ČSN 75 7837)
61 Drinking water Determination of Clostridium perfringens by membrane filtration
Regulated area: Microbiological tests
SOP 48 (ČSN EN ISO 14189)

Reference standards (105)

Návod firmy HACH
Příloha č. 6 vyhl. 252/2004 Sb.
SOP 01
SOP 02
SOP 03
SOP 04
SOP 05
SOP 06
SOP 07
SOP 08
SOP 08 A
SOP 10
SOP 11
SOP 12
SOP 13
SOP 13 A
SOP 14
SOP 15
SOP 16
SOP 17
SOP 18
SOP 19
SOP 20
SOP 21
SOP 22
SOP 23
SOP 24
SOP 25
SOP 26
SOP 27
SOP 30
SOP 31
SOP 36
SOP 38
SOP 39
SOP 40
SOP 42
SOP 45
SOP 46
SOP 46 A
SOP 46 B
SOP 47
SOP 48
SOP 49
SPP 01
SPP 02
SPP 03
SPP 04
SPP 05
TNI 75 7531
TNV 75 7431
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 741
ČSN 75 7477
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN 75 7837
ČSN EN 1622
ČSN EN 1899‒2
ČSN EN 25813
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN 903
ČSN EN ISO 14189
ČSN EN ISO 17289
ČSN EN ISO 19458
ČSN EN ISO 5667‒1
ČSN EN ISO 5667‒13
ČSN EN ISO 5667‒14
ČSN EN ISO 5667‒15
ČSN EN ISO 5667‒3
ČSN EN ISO 5667‒6
ČSN EN ISO 5814
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878
ČSN EN ISO 7027-1
ČSN EN ISO 7393‒2
ČSN EN ISO 7887
ČSN EN ISO 7899‒2
ČSN EN ISO 8467
ČSN EN ISO 9308‒1
ČSN EN ISO 9562
ČSN EN ISO 9963‒1
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 15705
ČSN ISO 23696-1
ČSN ISO 23697-1
ČSN ISO 5667-5
ČSN ISO 5667‒10
ČSN ISO 5667‒11
ČSN ISO 5667‒4
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150‒1
ČSN ISO 7890‒3
ČSN ISO 9297