🇨🇿 Vodovody a kanalizace Vsetín, a.s. PL
Water & wastewaterMicrobiology
Vodovody a kanalizace Vsetín, a.s. is a laboratory accredited by ČIA under number 1441 (Vsetín, Czech Republic). Its accreditation scope covers 61 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Waters, Drinking, ground, raw, surface water, Drinking, raw, ground, surface water, Waters, sludge.
At a glance
- Accreditation number: ČIA 1441
- Methods in scope: 61
- Types of test objects: 15
- City: Vsetín, Czech Republic
- Valid until: 03-11-2027
- Accreditation number
- 1441
- Accreditation body
- ČIA
- Address
- Jiráskova 1089, 755 01 Vsetín
- City
- Vsetín, Czech Republic
- Division
- Laboratorium Centralne
- Valid until
- 03-11-2027
What this laboratory tests (15)
- Waters — 30 methods
- Drinking, ground, raw, surface water — 5 methods
- Drinking, raw, ground, surface water — 4 methods
- Waters, sludge — 4 methods
- Drinking, raw, hot, ground, surface water — 3 methods
- Drinking water — 2 methods
- Ground water — 2 methods
- Sludge — 2 methods
- Surface water — 2 methods
- Waste water — 2 methods
- Drinking water, hot water — 1 method
- Drinking, hot, ground water — 1 method
- Drinking, hot, ground, raw, surface water — 1 method
- Drinking, raw, hot, ground water — 1 method
- Non-disinfected, raw, surface water — 1 method
Laboratory sections (3)
- Vsetín site — 38 methods
- Valašské Meziříčí site — 14 methods
- Karolinka site — 9 methods
Laboratory locations
- Pracownia Vsetín — Jiráskova 1089
- Pracownia Valašské Meziříčí — Hranická 69
- Pracownia Karolinka — Vodárenská 640
Certificate information
- Certificate date
- 23.06.2025
Accreditation scope — test methods (61)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Vsetín site | |||||
| 1 | Waters | Determination of ammonium ions by spectrophotometry and of ammonium nitrogen and inorganic nitrogen by calculation from measured values Regulated area: Chemical tests |
SOP 01 (ČSN ISO 7150‒1) | ||
| 2 | Waters | Determination of nitrite by spectrophotometry and of nitrite nitrogen by calculation from measured values Regulated area: Chemical tests |
SOP 02 (ČSN EN 26777) | ||
| 3 | Waters | Determination of nitrate by spectrophotometry Regulated area: Chemical tests |
SOP 03 (ČSN ISO 7890‒3) | ||
| 4 | Waters | Determination of chloride by titration Regulated area: Chemical tests |
SOP 04 (ČSN ISO 9297) | ||
| 5 | Waters | Determination of total iron by spectrophotometry with o-phenanthroline Regulated area: Chemical tests |
SOP 05 (ČSN ISO 6332) | ||
| 6 | Drinking, raw, ground, surface water | Determination of manganese by spectrophotometry Regulated area: Chemical tests |
SOP 06 (ČSN ISO 6333) | ||
| 7 | Drinking, raw, ground, surface water | Determination of aluminium by spectrophotometry Regulated area: Chemical tests |
SOP 07 (ČSN ISO 10566) | ||
| 8 | Drinking, raw, ground, surface water | Determination of calcium by titration Regulated area: Chemical tests |
SOP 08 (ČSN ISO 6058) | ||
| 9 | Drinking, raw, ground, surface water | Determination of the sum of calcium and magnesium by titration and calculation of magnesium from measured values Regulated area: Chemical tests |
SOP 08 A (ČSN ISO 6059) | ||
| 10 | Waters | Determination of temperature Regulated area: Chemical tests |
SOP 10 (ČSN 75 7342) | ||
| 11 | Waters | Determination of pH by potentiometry Regulated area: Chemical tests |
SOP 11 (ČSN ISO 10523) | ||
| 12 | Waters | Determination of electrical conductivity Regulated area: Chemical tests |
SOP 12 (ČSN EN 27888) | ||
| 13 | Drinking, raw, hot, ground, surface water | Determination of turbidity by turbidimetry Regulated area: Chemical tests |
SOP 13 (ČSN EN ISO 7027-1) | ||
| 14 | Waters | Determination of acid neutralizing capacity by titration Regulated area: Chemical tests |
SOP 14 (ČSN EN ISO 9963‒1) | ||
| 15 | Drinking, raw, hot, ground water | Determination of odour and taste by indicative sensory analysis Regulated area: Chemical tests |
SOP 15 (ČSN EN 1622; ČSN 75 7340) | ||
| 16 | Waters | Determination of chemical oxygen demand by permanganate by titration Regulated area: Chemical tests |
SOP 16 (ČSN EN ISO 8467) | ||
| 17 | Waters | Determination of chemical oxygen demand by dichromate by spectrophotometry with a HACH kit Regulated area: Chemical tests |
SOP 17 (ČSN ISO 15705; Návod firmy HACH) | ||
| 18 | Waters, sludge | Determination of suspended solids by gravimetry Regulated area: Chemical tests |
SOP 18 (ČSN EN 872) | ||
| 19 | Waters, sludge | Determination of dissolved solids, dissolved inorganic salts and total solids by gravimetry Regulated area: Chemical tests |
SOP 19 (ČSN 75 7346; ČSN 75 7347) | ||
| 20 | Waters | Determination of total phosphorus by spectrophotometry with a HACH kit and of phosphates by calculation from measured values Regulated area: Chemical tests |
SOP 20 (ČSN EN ISO 6878; Návod firmy HACH) | ||
| 21 | Waters | Determination of fluoride by spectrophotometry Regulated area: Chemical tests |
SOP 21 (TNV 75 7431) | ||
| 22 | Waters | Determination of anionic surfactants by spectrophotometry Regulated area: Chemical tests |
SOP 22 (ČSN EN 903) | ||
| 23 | Waters | Determination of sulphates by titration Regulated area: Chemical tests |
SOP 23 (ČSN 75 7477) | ||
| 24 | Drinking water, hot water | Determination of free and total chlorine by photometry Regulated area: Chemical tests |
SOP 24 (ČSN EN ISO 7393‒2) | ||
| 25 | Waters | Determination of nitrate nitrogen by spectrophotometry with a HACH kit Regulated area: Chemical tests |
SOP 36 (ČSN ISO 23696-1; Návod firmy HACH) | ||
| 26 | Drinking, raw, hot, ground, surface water | Determination of colour by photometry Regulated area: Chemical tests |
SOP 42 (ČSN EN ISO 7887) | ||
| 27 | Waters | Determination of total nitrogen by spectrophotometry with a HACH kit Regulated area: Chemical tests |
SOP 45 (ČSN ISO 23697-1; Návod firmy HACH) | ||
| 28 | Waters | Determination of biochemical oxygen demand after 5 days (BOD5) by iodometry Regulated area: Chemical tests |
SOP 46 (ČSN EN ISO 5815-1; ČSN EN 1899‒2; ČSN EN 25813) | ||
| 29 | Waters | Determination of biochemical oxygen demand after 5 days (BOD5) with an oximeter Regulated area: Chemical tests |
SOP 46 A (ČSN EN ISO 5815-1; ČSN EN 1899‒2; ČSN EN ISO 5814) | ||
| 30 | Drinking, raw, hot, ground, surface water | Determination of turbidity by nephelometry Regulated area: Chemical tests |
SOP 13 A (ČSN EN ISO 7027-1) | ||
| 31 | Waters | Determination of total cyanides (after distillation) by photometry Regulated area: Chemical tests |
SOP 47 (ČSN 75 741) | ||
| 32 | Waters | Determination of biochemical oxygen demand after 5 days (BOD5) with an oximeter Regulated area: Chemical tests |
SOP 46 B (ČSN EN ISO 5815-1; ČSN EN 1899‒2; ČSN EN ISO 17289) | ||
| 33 | Waters | Determination of adsorbable organically bound halogens (AOX) by coulometry Regulated area: Chemical tests |
SOP 49 (ČSN EN ISO 9562; TNI 75 7531) | ||
| 34 | Surface water | Sampling of surface water from rivers, streams and reservoirs manually and with an automatic sampler Regulated area: Sampling |
SPP 01 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN ISO 5667‒4; ČSN EN ISO 5667‒6; ČSN EN ISO 5667‒14; ČSN EN ISO 19458) | ||
| 35 | Drinking water | Sampling of drinking water Regulated area: Sampling |
SPP 02 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN ISO 5667-5; ČSN EN ISO 5667‒14; ČSN EN ISO 19458) | ||
| 36 | Sludge | Sampling of sludge Regulated area: Sampling |
SPP 03 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN EN ISO 5667‒13; ČSN EN ISO 5667‒14; ČSN EN ISO 5667‒15) | ||
| 37 | Waste water | Sampling of waste water manually and with an automatic sampler Regulated area: Sampling |
SPP 04 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN ISO 5667‒10; ČSN EN ISO 5667‒14) | ||
| 38 | Ground water | Sampling of ground water manually and with a pump (static sampling) Regulated area: Sampling |
SPP 05 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN ISO 5667‒11; ČSN EN ISO 5667‒14) | ||
| Valašské Meziříčí site | |||||
| 39 | Waters | Determination of ammonium ions by spectrophotometry and of ammonium nitrogen and inorganic nitrogen by calculation from measured values Regulated area: Chemical tests |
SOP 01 (ČSN ISO 7150‒1) | ||
| 40 | Waters | Determination of nitrite by spectrophotometry and of nitrite nitrogen by calculation from measured values Regulated area: Chemical tests |
SOP 02 (ČSN EN 26777) | ||
| 41 | Waters | Determination of pH by potentiometry Regulated area: Chemical tests |
SOP 11 (ČSN ISO 10523) | ||
| 42 | Waters | Determination of chemical oxygen demand by dichromate by spectrophotometry with a HACH kit Regulated area: Chemical tests |
SOP 17 (ČSN ISO 15705; Návod firmy HACH) | ||
| 43 | Waters, sludge | Determination of suspended solids by gravimetry Regulated area: Chemical tests |
SOP 18 (ČSN EN 872) | ||
| 44 | Waters, sludge | Determination of dissolved solids, dissolved inorganic salts and total solids by gravimetry Regulated area: Chemical tests |
SOP 19 (ČSN 75 7346; ČSN 75 7347) | ||
| 45 | Waters | Determination of total phosphorus by spectrophotometry with a HACH kit and of phosphates by calculation from measured values Regulated area: Chemical tests |
SOP 20 (ČSN EN ISO 6878; Návod firmy HACH) | ||
| 46 | Waters | Determination of nitrate nitrogen by spectrophotometry with a HACH kit Regulated area: Chemical tests |
SOP 36 (ČSN ISO 23696-1; Návod firmy HACH) | ||
| 47 | Waters | Determination of total nitrogen by spectrophotometry with a HACH kit Regulated area: Chemical tests |
SOP 45 (ČSN ISO 23697-1; Návod firmy HACH) | ||
| 48 | Waters | Determination of biochemical oxygen demand after 5 days (BOD5) by iodometry Regulated area: Chemical tests |
SOP 46 (ČSN EN ISO 5815-1; ČSN EN 1899‒2; ČSN EN 25813) | ||
| 49 | Surface water | Sampling of surface water from rivers, streams and reservoirs manually and with an automatic sampler Regulated area: Sampling |
SPP 01 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN ISO 5667‒4; ČSN EN ISO 5667‒6; ČSN EN ISO 5667‒14; ČSN EN ISO 19458) | ||
| 50 | Sludge | Sampling of sludge Regulated area: Sampling |
SPP 03 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN EN ISO 5667‒13; ČSN EN ISO 5667‒14; ČSN EN ISO 5667‒15) | ||
| 51 | Waste water | Sampling of waste water manually and with an automatic sampler Regulated area: Sampling |
SPP 04 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN ISO 5667‒10; ČSN EN ISO 5667‒14) | ||
| 52 | Ground water | Sampling of ground water manually and with a pump (static sampling) Regulated area: Sampling |
SPP 05 (ČSN EN ISO 5667‒1; ČSN EN ISO 5667‒3; ČSN ISO 5667‒11; ČSN EN ISO 5667‒14) | ||
| Karolinka site | |||||
| 53 | Drinking, ground, raw, surface water | Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration Regulated area: Microbiological tests |
SOP 25 (ČSN 75 7835) | ||
| 54 | Drinking, hot, ground water | Determination of coliform bacteria and Escherichia coli by membrane filtration Regulated area: Microbiological tests |
SOP 26 (ČSN EN ISO 9308‒1) | ||
| 55 | Drinking, ground, raw, surface water | Determination of intestinal enterococci by membrane filtration Regulated area: Microbiological tests |
SOP 27 (ČSN EN ISO 7899‒2) | ||
| 56 | Drinking, ground, raw, surface water | Determination of bioseston by microscopy Regulated area: Microbiological tests |
SOP 30 (ČSN 75 7712) | ||
| 57 | Drinking, ground, raw, surface water | Determination of abioseston by microscopy Regulated area: Microbiological tests |
SOP 31 (ČSN 75 7713) | ||
| 58 | Drinking, ground, raw, surface water | Determination of Clostridium perfringens by membrane filtration Regulated area: Microbiological tests |
SOP 38 (Příloha č. 6 vyhl. 252/2004 Sb.) | ||
| 59 | Drinking, hot, ground, raw, surface water | Enumeration of culturable microorganisms at 22 °C and 36 °C by direct plating Regulated area: Microbiological tests |
SOP 39 (ČSN EN ISO 6222) | ||
| 60 | Non-disinfected, raw, surface water | Determination of coliform bacteria by membrane filtration Regulated area: Microbiological tests |
SOP 40 (ČSN 75 7837) | ||
| 61 | Drinking water | Determination of Clostridium perfringens by membrane filtration Regulated area: Microbiological tests |
SOP 48 (ČSN EN ISO 14189) | ||
Reference standards (105)
Návod firmy HACH
Příloha č. 6 vyhl. 252/2004 Sb.
SOP 01
SOP 02
SOP 03
SOP 04
SOP 05
SOP 06
SOP 07
SOP 08
SOP 08 A
SOP 10
SOP 11
SOP 12
SOP 13
SOP 13 A
SOP 14
SOP 15
SOP 16
SOP 17
SOP 18
SOP 19
SOP 20
SOP 21
SOP 22
SOP 23
SOP 24
SOP 25
SOP 26
SOP 27
SOP 30
SOP 31
SOP 36
SOP 38
SOP 39
SOP 40
SOP 42
SOP 45
SOP 46
SOP 46 A
SOP 46 B
SOP 47
SOP 48
SOP 49
SPP 01
SPP 02
SPP 03
SPP 04
SPP 05
TNI 75 7531
TNV 75 7431
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 741
ČSN 75 7477
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN 75 7837
ČSN EN 1622
ČSN EN 1899‒2
ČSN EN 25813
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN 903
ČSN EN ISO 14189
ČSN EN ISO 17289
ČSN EN ISO 19458
ČSN EN ISO 5667‒1
ČSN EN ISO 5667‒13
ČSN EN ISO 5667‒14
ČSN EN ISO 5667‒15
ČSN EN ISO 5667‒3
ČSN EN ISO 5667‒6
ČSN EN ISO 5814
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878
ČSN EN ISO 7027-1
ČSN EN ISO 7393‒2
ČSN EN ISO 7887
ČSN EN ISO 7899‒2
ČSN EN ISO 8467
ČSN EN ISO 9308‒1
ČSN EN ISO 9562
ČSN EN ISO 9963‒1
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 15705
ČSN ISO 23696-1
ČSN ISO 23697-1
ČSN ISO 5667-5
ČSN ISO 5667‒10
ČSN ISO 5667‒11
ČSN ISO 5667‒4
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150‒1
ČSN ISO 7890‒3
ČSN ISO 9297