🇨🇿 STACHEMA Kolín s.r.o. PL
Construction
STACHEMA Kolín s.r.o. is a laboratory accredited by ČIA under number 1433 (Kolín, Czech Republic). Its accreditation scope covers 30 test methods in the following areas: Construction. Test objects include: Fresh concrete, Hardened concrete, Repair materials, Concrete paving blocks. Most frequently used techniques: Flow table test, Pressure gauge method, Slump test.
At a glance
- Accreditation number: ČIA 1433
- Methods in scope: 30
- Types of test objects: 6
- Techniques used: 6
- City: Kolín, Czech Republic
- Valid until: 15-06-2027
- Accreditation number
- 1433
- Accreditation body
- ČIA
- Address
- Hasičská 1, Zibohlavy, 280 02 Kolín
- City
- Kolín, Czech Republic
- Division
- Laboratorium Badawcze
- Valid until
- 15-06-2027
What this laboratory tests (6)
- Fresh concrete — 13 methods
- Hardened concrete — 12 methods
- Repair materials — 2 methods
- Concrete paving blocks — 1 method
- Mortars and mortar mixtures — 1 method
- Screed materials — 1 method
Analytical techniques used (6)
- Flow table test — 2 methods
- Pressure gauge method — 2 methods
- Slump test — 2 methods
- Slump-flow test — 2 methods
- Degree of compactability — 1 method
- Pull-off test — 1 method
Laboratory sections (2)
- Site 1 — 17 methods
- Site 2 — 13 methods
Laboratory locations
- Pracownia 1 — Hasičská 1, Zibohlavy
- Pracownia 2 — Macháčkova 27, Zibohlavy
Certificate information
- Certificate date
- 22.12.2025
Accreditation scope — test methods (30)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Site 1 | |||||
| 1 | Fresh concrete | Determination of consistency Regulated area: Tests |
Slump test | ČSN EN 12350-2 | |
| 2 | Fresh concrete | Determination of consistency Regulated area: Tests |
Flow table test | ČSN EN 12350-5 | |
| 3 | Fresh concrete | Determination of air content Regulated area: Tests |
Pressure gauge method | ČSN EN 12350-7, mimo kapitolu 5 | |
| 4 | Fresh concrete | Determination of density Regulated area: Tests |
ČSN EN 12350-6 | ||
| 5 | Hardened concrete | Determination of density on test cubes Regulated area: Tests |
ČSN EN 12390-7, mimo články 6.5.2 až 6.5.4 | ||
| 6 | Hardened concrete | Determination of compressive strength of test specimens Regulated area: Tests |
ČSN EN 12390-3 | ||
| 7 | Hardened concrete | Determination of flexural strength of test specimens Regulated area: Tests |
ČSN EN 12390-5 | ||
| 8 | Hardened concrete | Determination of depth of penetration of water under pressure Regulated area: Tests |
ČSN EN 12390-8 | ||
| 9 | Fresh concrete | Determination of consistency Regulated area: Tests |
Slump-flow test | ČSN EN 12350-8 | |
| 10 | Hardened concrete | Determination of frost resistance Regulated area: Tests |
ČSN 73 1322 | ||
| 11 | Hardened concrete | Determination of resistance of the surface of cement concrete to water and chemical de-icing agents Regulated area: Tests |
ČSN 73 1326, metoda A; ČSN 73 1326, metoda C | ||
| 12 | Fresh concrete | Determination of consistency Regulated area: Tests |
Degree of compactability | ČSN EN 12350-4 | |
| 13 | Hardened concrete | Determination of static modulus of elasticity in compression Regulated area: Tests |
ČSN ISO 1920-10 | ||
| 14 | Repair materials | Determination of modulus of elasticity in compression Regulated area: Tests |
ČSN EN 13412, článek 7.5 - metoda 2 | ||
| 15 | Hardened concrete | Determination of air void characteristics in hardened concrete Regulated area: Tests |
ČSN EN 480-11 | ||
| 16 | Concrete paving blocks | Determination of tensile splitting strength Regulated area: Tests |
ČSN EN 1338, příloha F | ||
| 17 | Fresh concrete | Sampling of fresh concrete Regulated area: Sampling |
ČSN EN 12350-1 | ||
| Site 2 | |||||
| 18 | Fresh concrete | Determination of consistency Regulated area: Tests |
Slump test | ČSN EN 12350-2 | |
| 19 | Fresh concrete | Determination of consistency Regulated area: Tests |
Flow table test | ČSN EN 12350-5 | |
| 20 | Fresh concrete | Determination of air content Regulated area: Tests |
Pressure gauge method | ČSN EN 12350-7, mimo kapitolu 5 | |
| 21 | Fresh concrete | Determination of density Regulated area: Tests |
ČSN EN 12350-6 | ||
| 22 | Hardened concrete | Determination of density on test cubes Regulated area: Tests |
ČSN EN 12390-7, mimo články 6.5.2 až 6.5.4 | ||
| 23 | Hardened concrete | Determination of compressive strength of test specimens Regulated area: Tests |
ČSN EN 12390-3 | ||
| 24 | Hardened concrete | Determination of depth of penetration of water under pressure Regulated area: Tests |
ČSN EN 12390-8 | ||
| 25 | Fresh concrete | Determination of consistency Regulated area: Tests |
Slump-flow test | ČSN EN 12350-8 | |
| 26 | Hardened concrete | Determination of resistance of the surface of cement concrete to water and chemical de-icing agents Regulated area: Tests |
ČSN 73 1326, metoda A; ČSN 73 1326, metoda C | ||
| 27 | Screed materials | Determination of flexural and compressive strength Regulated area: Tests |
ČSN EN 13892-2, vyjma zhotovení těles | ||
| 28 | Mortars and mortar mixtures | Determination of compressive strength Regulated area: Tests |
ČSN EN 12190, vyjma zhotovení těles | ||
| 29 | Repair materials | Determination of bond strength Regulated area: Tests |
Pull-off test | ČSN EN 1542 | |
| 30 | Fresh concrete | Sampling of fresh concrete Regulated area: Sampling |
ČSN EN 12350-1 | ||
Reference standards (21)
ČSN 73 1322
ČSN 73 1326, metoda A
ČSN 73 1326, metoda C
ČSN EN 12190, vyjma zhotovení těles
ČSN EN 12350-1
ČSN EN 12350-2
ČSN EN 12350-4
ČSN EN 12350-5
ČSN EN 12350-6
ČSN EN 12350-7, mimo kapitolu 5
ČSN EN 12350-8
ČSN EN 12390-3
ČSN EN 12390-5
ČSN EN 12390-7, mimo články 6.5.2 až 6.5.4
ČSN EN 12390-8
ČSN EN 1338, příloha F
ČSN EN 13412, článek 7.5 - metoda 2
ČSN EN 13892-2, vyjma zhotovení těles
ČSN EN 1542
ČSN EN 480-11
ČSN ISO 1920-10