🇨🇿 Zdeněk Lommer – LOLA s.r.o. PL
Water & wastewaterMicrobiology
Zdeněk Lommer – LOLA s.r.o. is a laboratory accredited by ČIA under number 1432 (Kdyně, Czech Republic). Its accreditation scope covers 39 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Drinking, ground, surface water, Drinking, ground, surface, waste water, Drinking, ground, surface water, bathing water, Drinking, ground, surface, waste water, bathing water.
At a glance
- Accreditation number: ČIA 1432
- Methods in scope: 39
- Types of test objects: 12
- City: Kdyně, Czech Republic
- Valid until: 06-04-2027
- Accreditation number
- 1432
- Accreditation body
- ČIA
- Address
- Lesní 41, 345 06 Kdyně
- City
- Kdyně, Czech Republic
- Division
- Zdeněk Lommer – firma LOLA
- Valid until
- 06-04-2027
What this laboratory tests (12)
- Drinking, ground, surface water — 12 methods
- Drinking, ground, surface, waste water — 6 methods
- Drinking, ground, surface water, bathing water — 4 methods
- Drinking, ground, surface, waste water, bathing water — 4 methods
- Drinking, ground water, bathing water — 3 methods
- Surface, ground, waste water — 3 methods
- Bathing water — 2 methods
- Drinking and raw water — 1 method
- Drinking water, bathing water — 1 method
- Drinking, ground, surface water and bathing water — 1 method
- Ground, surface, waste water, bathing water — 1 method
- Waste water — 1 method
Certificate information
- Certificate date
- 22.12.2025
Accreditation scope — test methods (39)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Drinking, ground, surface, waste water, bathing water | Determination of pH by potentiometry Regulated area: Tests |
SOP 01/CH (ČSN ISO 10523) | ||
| 2 | Drinking, ground, surface, waste water | Determination of acid neutralizing capacity (ANC4.5) by titration Regulated area: Tests |
SOP 02/CH (ČSN EN ISO 9963-1) | ||
| 3 | Drinking, ground, surface water | Determination of the sum of calcium and magnesium (total hardness) by titration and of magnesium by calculation Regulated area: Tests |
SOP 03/CH (ČSN ISO 6059) | ||
| 4 | Drinking, ground, surface water | Determination of calcium by titration Regulated area: Tests |
SOP 03/CH, část B (ČSN ISO 6058) | ||
| 5 | Drinking, ground, surface, waste water | Determination of electrical conductivity Regulated area: Tests |
SOP 04/CH (ČSN EN 27888) | ||
| 6 | Drinking, ground, surface water | Determination of iron by photometry Regulated area: Tests |
SOP 05/CH (ČSN ISO 6332) | ||
| 7 | Drinking, ground, surface water | Determination of manganese by photometry Regulated area: Tests |
SOP 06/CH (ČSN ISO 6333) | ||
| 8 | Drinking, ground, surface, waste water, bathing water | Determination of ammonium ions (NH4+) by photometry and of ammonium nitrogen (N-NH4+) by calculation from measured values Regulated area: Tests |
SOP 07/CH (ČSN ISO 7150-1) | ||
| 9 | Drinking, ground, surface, waste water, bathing water | Determination of nitrate (NO3-) by photometry and of nitrate nitrogen (N-NO3-) by calculation from measured values Regulated area: Tests |
SOP 08/CH (ČSN ISO 7890-3) | ||
| 10 | Drinking, ground, surface, waste water | Determination of nitrite (NO2-) by photometry and of nitrite nitrogen (N-NO2-) by calculation from measured values Regulated area: Tests |
SOP 09/CH (ČSN EN 26777) | ||
| 11 | Drinking, ground, surface, waste water | Determination of chloride by titration Regulated area: Tests |
SOP 10/CH (ČSN ISO 9297) | ||
| 12 | Surface, ground, waste water | Determination of suspended solids by gravimetry Regulated area: Tests |
SOP 13/CH (ČSN EN 872) | ||
| 13 | Surface, ground, waste water | Determination of biochemical oxygen demand (BOD5) by titration Regulated area: Tests |
SOP 15/CH (ČSN EN ISO 5815-1) | ||
| 14 | Surface, ground, waste water | Determination of chemical oxygen demand (CODCr) by photometry Regulated area: Tests |
SOP 16/CH (ČSN ISO 15705) | ||
| 15 | Drinking, ground, surface, waste water | Determination of sulphates by titration Regulated area: Tests |
SOP 17/CH (ČSN 75 7477) | ||
| 16 | Ground, surface, waste water, bathing water | Determination of orthophosphate and total phosphorus by photometry Regulated area: Tests |
SOP 18/CH (ČSN EN ISO 6878, čl. 4 a čl. 7) | ||
| 17 | Drinking, ground, surface, waste water | Determination of dried and ignited dissolved solids by gravimetry Regulated area: Tests |
SOP 20/CH (ČSN 75 7346) | ||
| 18 | Drinking, ground water, bathing water | Determination of turbidity by nephelometry Regulated area: Tests |
SOP 21/CH (ČSN EN ISO 7027-1) | ||
| 19 | Drinking, ground, surface water | Determination of colour by colorimetry using a commercial analytical kit Regulated area: Tests |
SOP 22/CH (manuál firmy MERCK) | ||
| 20 | Drinking, ground, surface water and bathing water | Determination of total organic carbon (TOC) with an analyser after oxidative UV digestion Regulated area: Tests |
SOP 40/CH (ČSN EN 1484) | ||
| 21 | Drinking water, bathing water | Determination of free and total chlorine by photometry combined chlorine by calculation from measured values (calculated) Regulated area: Tests |
SOP 24/CH (ČSN ISO 7393-2) | ||
| 22 | Bathing water | Determination of oxidation-reduction potential Regulated area: Tests |
SOP 25/CH (ČSN 75 7367) | ||
| 23 | Drinking, ground, surface water | Determination of lead, cadmium, copper, nickel and chromium by flame AAS Regulated area: Tests |
SOP 35/CH (ČSN ISO 8828; ČSN EN 1233) | ||
| 24 | Drinking, ground, surface water | Determination of sodium by flame AAS Regulated area: Tests |
SOP 34/CH (ČSN ISO 9964-1) | ||
| 25 | Drinking, ground, surface water | Determination of trace elements by graphite furnace AAS As Be Cr Sb Se Regulated area: Tests |
SOP 44/CH (ČSN EN ISO 15586) | ||
| 26 | Drinking, ground, surface water | Determination of fluoride by an electrochemical method Regulated area: Tests |
SOP 38/CH (ČSN ISO 10359-1) | ||
| 27 | Drinking, ground, surface water | Determination of aluminium by photometry Regulated area: Tests |
SOP 33/CH (ČSN ISO 10566) | ||
| 28 | Drinking, ground, surface water | Determination of selected elements by ICP-OES As Al B Ba Be Cd Co Cr Cu Fe Mn Ni Pb Se Sb V Zn Regulated area: Tests |
SOP 31/CH (ČSN EN ISO 11885) | ||
| 29 | Drinking, ground, surface water | Determination of potassium by flame AAS Regulated area: Tests |
SOP 23/CH (ČSN ISO 9964-2) | ||
| 30 | Drinking, ground, surface, waste water, bathing water | Determination of temperature Regulated area: Tests |
SOP 41/CH (ČSN 75 7342) | ||
| 31 | Drinking, ground, surface water, bathing water | Determination of coliform bacteria by the membrane filtration culture method Regulated area: Tests |
SOP 01/M (ČSN 75 7837) | ||
| 32 | Drinking, ground, surface water, bathing water | Determination of intestinal enterococci by the membrane filtration culture method Regulated area: Tests |
SOP 02/M (ČSN EN ISO 7899-2) | ||
| 33 | Drinking, ground, surface water, bathing water | Determination of thermotolerant coliform bacteria by the membrane filtration culture method Regulated area: Tests |
SOP 05/M (ČSN 75 7835) | ||
| 34 | Drinking, ground water, bathing water | Determination of coliform bacteria and Escherichia coli by the membrane filtration culture method Regulated area: Tests |
SOP 06/M (ČSN EN ISO 9308-1) | ||
| 35 | Drinking, ground, surface water, bathing water | Enumeration of culturable microorganisms by culture at 22 °C and 36 °C Regulated area: Tests |
SOP 08/M (ČSN EN ISO 6222) | ||
| 36 | Drinking, ground water, bathing water | Determination of Pseudomonas aeruginosa by the membrane filtration culture method Regulated area: Tests |
SOP 10/M (ČSN EN ISO 16266) | ||
| 37 | Drinking and raw water | Sampling of drinking and raw water Regulated area: Sampling |
SOP 01/T/A (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458) | ||
| 38 | Waste water | Sampling of waste water manually and with an automatic sampler Regulated area: Sampling |
SOP 01/T/B (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14) | ||
| 39 | Bathing water | Sampling of bathing water Regulated area: Sampling |
SOP 01/T/C (Vyhláška č. 238/2011 Sb.; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-14; ČSN EN ISO 19458) | ||
Reference standards (84)
SOP 01/CH
SOP 01/M
SOP 01/T/A
SOP 01/T/B
SOP 01/T/C
SOP 02/CH
SOP 02/M
SOP 03/CH
SOP 03/CH, část B
SOP 04/CH
SOP 05/CH
SOP 05/M
SOP 06/CH
SOP 06/M
SOP 07/CH
SOP 08/CH
SOP 08/M
SOP 09/CH
SOP 10/CH
SOP 10/M
SOP 13/CH
SOP 15/CH
SOP 16/CH
SOP 17/CH
SOP 18/CH
SOP 20/CH
SOP 21/CH
SOP 22/CH
SOP 23/CH
SOP 24/CH
SOP 25/CH
SOP 31/CH
SOP 33/CH
SOP 34/CH
SOP 35/CH
SOP 38/CH
SOP 40/CH
SOP 41/CH
SOP 44/CH
Vyhláška č. 238/2011 Sb.
manuál firmy MERCK
ČSN 75 7342
ČSN 75 7346
ČSN 75 7367
ČSN 75 7477
ČSN 75 7835
ČSN 75 7837
ČSN EN 1233
ČSN EN 1484
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 11885
ČSN EN ISO 15586
ČSN EN ISO 16266
ČSN EN ISO 19458
ČSN EN ISO 5667-1
ČSN EN ISO 5667-14
ČSN EN ISO 5667-3
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878, čl. 4 a čl. 7
ČSN EN ISO 7027-1
ČSN EN ISO 7899-2
ČSN EN ISO 9308-1
ČSN EN ISO 9963-1
ČSN ISO 10359-1
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 15705
ČSN ISO 5667-10
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150-1
ČSN ISO 7393-2
ČSN ISO 7890-3
ČSN ISO 8828
ČSN ISO 9297
ČSN ISO 9964-1
ČSN ISO 9964-2