🇨🇿 Zdeněk Lommer – LOLA s.r.o. PL

ČIA 1432 • Kdyně, Czech Republic • 39 methods

Water & wastewaterMicrobiology

Zdeněk Lommer – LOLA s.r.o. is a laboratory accredited by ČIA under number 1432 (Kdyně, Czech Republic). Its accreditation scope covers 39 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Drinking, ground, surface water, Drinking, ground, surface, waste water, Drinking, ground, surface water, bathing water, Drinking, ground, surface, waste water, bathing water.

At a glance

  • Accreditation number: ČIA 1432
  • Methods in scope: 39
  • Types of test objects: 12
  • City: Kdyně, Czech Republic
  • Valid until: 06-04-2027
Accreditation number
1432
Accreditation body
ČIA
Address
Lesní 41, 345 06 Kdyně
City
Kdyně, Czech Republic
Division
Zdeněk Lommer – firma LOLA
Valid until
06-04-2027

What this laboratory tests (12)

Certificate information

Certificate date
22.12.2025

Accreditation scope — test methods (39)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Drinking, ground, surface, waste water, bathing water Determination of pH by potentiometry
Regulated area: Tests
SOP 01/CH (ČSN ISO 10523)
2 Drinking, ground, surface, waste water Determination of acid neutralizing capacity (ANC4.5) by titration
Regulated area: Tests
SOP 02/CH (ČSN EN ISO 9963-1)
3 Drinking, ground, surface water Determination of the sum of calcium and magnesium (total hardness) by titration and of magnesium by calculation
Regulated area: Tests
SOP 03/CH (ČSN ISO 6059)
4 Drinking, ground, surface water Determination of calcium by titration
Regulated area: Tests
SOP 03/CH, část B (ČSN ISO 6058)
5 Drinking, ground, surface, waste water Determination of electrical conductivity
Regulated area: Tests
SOP 04/CH (ČSN EN 27888)
6 Drinking, ground, surface water Determination of iron by photometry
Regulated area: Tests
SOP 05/CH (ČSN ISO 6332)
7 Drinking, ground, surface water Determination of manganese by photometry
Regulated area: Tests
SOP 06/CH (ČSN ISO 6333)
8 Drinking, ground, surface, waste water, bathing water Determination of ammonium ions (NH4+) by photometry and of ammonium nitrogen (N-NH4+) by calculation from measured values
Regulated area: Tests
SOP 07/CH (ČSN ISO 7150-1)
9 Drinking, ground, surface, waste water, bathing water Determination of nitrate (NO3-) by photometry and of nitrate nitrogen (N-NO3-) by calculation from measured values
Regulated area: Tests
SOP 08/CH (ČSN ISO 7890-3)
10 Drinking, ground, surface, waste water Determination of nitrite (NO2-) by photometry and of nitrite nitrogen (N-NO2-) by calculation from measured values
Regulated area: Tests
SOP 09/CH (ČSN EN 26777)
11 Drinking, ground, surface, waste water Determination of chloride by titration
Regulated area: Tests
SOP 10/CH (ČSN ISO 9297)
12 Surface, ground, waste water Determination of suspended solids by gravimetry
Regulated area: Tests
SOP 13/CH (ČSN EN 872)
13 Surface, ground, waste water Determination of biochemical oxygen demand (BOD5) by titration
Regulated area: Tests
SOP 15/CH (ČSN EN ISO 5815-1)
14 Surface, ground, waste water Determination of chemical oxygen demand (CODCr) by photometry
Regulated area: Tests
SOP 16/CH (ČSN ISO 15705)
15 Drinking, ground, surface, waste water Determination of sulphates by titration
Regulated area: Tests
SOP 17/CH (ČSN 75 7477)
16 Ground, surface, waste water, bathing water Determination of orthophosphate and total phosphorus by photometry
Regulated area: Tests
SOP 18/CH (ČSN EN ISO 6878, čl. 4 a čl. 7)
17 Drinking, ground, surface, waste water Determination of dried and ignited dissolved solids by gravimetry
Regulated area: Tests
SOP 20/CH (ČSN 75 7346)
18 Drinking, ground water, bathing water Determination of turbidity by nephelometry
Regulated area: Tests
SOP 21/CH (ČSN EN ISO 7027-1)
19 Drinking, ground, surface water Determination of colour by colorimetry using a commercial analytical kit
Regulated area: Tests
SOP 22/CH (manuál firmy MERCK)
20 Drinking, ground, surface water and bathing water Determination of total organic carbon (TOC) with an analyser after oxidative UV digestion
Regulated area: Tests
SOP 40/CH (ČSN EN 1484)
21 Drinking water, bathing water Determination of free and total chlorine by photometry
combined chlorine by calculation from measured values (calculated)
Regulated area: Tests
SOP 24/CH (ČSN ISO 7393-2)
22 Bathing water Determination of oxidation-reduction potential
Regulated area: Tests
SOP 25/CH (ČSN 75 7367)
23 Drinking, ground, surface water Determination of lead, cadmium, copper, nickel and chromium by flame AAS
Regulated area: Tests
SOP 35/CH (ČSN ISO 8828; ČSN EN 1233)
24 Drinking, ground, surface water Determination of sodium by flame AAS
Regulated area: Tests
SOP 34/CH (ČSN ISO 9964-1)
25 Drinking, ground, surface water Determination of trace elements by graphite furnace AAS
As Be Cr Sb Se
Regulated area: Tests
SOP 44/CH (ČSN EN ISO 15586)
26 Drinking, ground, surface water Determination of fluoride by an electrochemical method
Regulated area: Tests
SOP 38/CH (ČSN ISO 10359-1)
27 Drinking, ground, surface water Determination of aluminium by photometry
Regulated area: Tests
SOP 33/CH (ČSN ISO 10566)
28 Drinking, ground, surface water Determination of selected elements by ICP-OES
As Al B Ba Be Cd Co Cr Cu Fe Mn Ni Pb Se Sb V Zn
Regulated area: Tests
SOP 31/CH (ČSN EN ISO 11885)
29 Drinking, ground, surface water Determination of potassium by flame AAS
Regulated area: Tests
SOP 23/CH (ČSN ISO 9964-2)
30 Drinking, ground, surface, waste water, bathing water Determination of temperature
Regulated area: Tests
SOP 41/CH (ČSN 75 7342)
31 Drinking, ground, surface water, bathing water Determination of coliform bacteria by the membrane filtration culture method
Regulated area: Tests
SOP 01/M (ČSN 75 7837)
32 Drinking, ground, surface water, bathing water Determination of intestinal enterococci by the membrane filtration culture method
Regulated area: Tests
SOP 02/M (ČSN EN ISO 7899-2)
33 Drinking, ground, surface water, bathing water Determination of thermotolerant coliform bacteria by the membrane filtration culture method
Regulated area: Tests
SOP 05/M (ČSN 75 7835)
34 Drinking, ground water, bathing water Determination of coliform bacteria and Escherichia coli by the membrane filtration culture method
Regulated area: Tests
SOP 06/M (ČSN EN ISO 9308-1)
35 Drinking, ground, surface water, bathing water Enumeration of culturable microorganisms by culture at 22 °C and 36 °C
Regulated area: Tests
SOP 08/M (ČSN EN ISO 6222)
36 Drinking, ground water, bathing water Determination of Pseudomonas aeruginosa by the membrane filtration culture method
Regulated area: Tests
SOP 10/M (ČSN EN ISO 16266)
37 Drinking and raw water Sampling of drinking and raw water
Regulated area: Sampling
SOP 01/T/A (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
38 Waste water Sampling of waste water manually and with an automatic sampler
Regulated area: Sampling
SOP 01/T/B (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)
39 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP 01/T/C (Vyhláška č. 238/2011 Sb.; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-14; ČSN EN ISO 19458)

Reference standards (84)

SOP 01/CH
SOP 01/M
SOP 01/T/A
SOP 01/T/B
SOP 01/T/C
SOP 02/CH
SOP 02/M
SOP 03/CH
SOP 03/CH, část B
SOP 04/CH
SOP 05/CH
SOP 05/M
SOP 06/CH
SOP 06/M
SOP 07/CH
SOP 08/CH
SOP 08/M
SOP 09/CH
SOP 10/CH
SOP 10/M
SOP 13/CH
SOP 15/CH
SOP 16/CH
SOP 17/CH
SOP 18/CH
SOP 20/CH
SOP 21/CH
SOP 22/CH
SOP 23/CH
SOP 24/CH
SOP 25/CH
SOP 31/CH
SOP 33/CH
SOP 34/CH
SOP 35/CH
SOP 38/CH
SOP 40/CH
SOP 41/CH
SOP 44/CH
Vyhláška č. 238/2011 Sb.
manuál firmy MERCK
ČSN 75 7342
ČSN 75 7346
ČSN 75 7367
ČSN 75 7477
ČSN 75 7835
ČSN 75 7837
ČSN EN 1233
ČSN EN 1484
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 11885
ČSN EN ISO 15586
ČSN EN ISO 16266
ČSN EN ISO 19458
ČSN EN ISO 5667-1
ČSN EN ISO 5667-14
ČSN EN ISO 5667-3
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878, čl. 4 a čl. 7
ČSN EN ISO 7027-1
ČSN EN ISO 7899-2
ČSN EN ISO 9308-1
ČSN EN ISO 9963-1
ČSN ISO 10359-1
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 15705
ČSN ISO 5667-10
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150-1
ČSN ISO 7393-2
ČSN ISO 7890-3
ČSN ISO 8828
ČSN ISO 9297
ČSN ISO 9964-1
ČSN ISO 9964-2

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1432