🇨🇿 1. SčV, a.s. PL

ČIA 1430 • Příbram IX, Czech Republic • 44 methods

Water & wastewaterMicrobiology

1. SčV, a.s. is a laboratory accredited by ČIA under number 1430 (Příbram IX, Czech Republic). Its accreditation scope covers 44 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Drinking, raw, ground and surface water, Drinking, raw, ground and surface water, bathing water, Surface water, waste water, Drinking, raw, ground, surface and waste water, bathing water. Most frequently used techniques: membrane filtration method, spectrophotometric method, gravimetric method.

At a glance

  • Accreditation number: ČIA 1430
  • Methods in scope: 44
  • Types of test objects: 11
  • Techniques used: 19
  • City: Příbram IX, Czech Republic
  • Valid until: 11-04-2027
Accreditation number
1430
Accreditation body
ČIA
Address
Novohospodská 93, 261 80 Příbram IX
City
Příbram IX, Czech Republic
Division
Laboratorium 1.SčV, a.s., Příbram
Valid until
11-04-2027

What this laboratory tests (11)

Analytical techniques used (19)

Certificate information

Certificate date
19.12.2024

Accreditation scope — test methods (44)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Drinking, raw, ground, surface and waste water, bathing water Determination of pH by potentiometry
Regulated area: Tests
potentiometric method SOP č.CH-01 (ČSN ISO 10523)
2 Drinking, raw, ground and surface water Determination of acid neutralising capacity KNK4.5 by titration
Regulated area: Tests
titrimetric method SOP č.CH-02 (ČSN EN ISO 9963-1)
3 Drinking, raw, ground and surface water Determination of base neutralising capacity ZNK8.3 by titration and calculation of the forms of carbon dioxide
forms of carbon dioxide by calculation (calculated)
Regulated area: Tests
titrimetric method SOP č.CH-18 (ČSN 75 7372; ČSN 75 7373)
4 Drinking, raw, ground, surface and waste water Determination of ammonium ions (NH4+) spectrophotometrically and ammonium nitrogen (N-NH4) by calculation
ammonium nitrogen (N-NH4) by calculation (calculated)
Regulated area: Tests
spectrophotometric method SOP č.CH-03 (ČSN ISO 7150-1)
5 Drinking, raw, ground, surface and waste water Determination of nitrites (NO2-) spectrophotometrically and nitrite nitrogen (N-NO2) by calculation
nitrite nitrogen (N-NO2) by calculation (calculated)
Regulated area: Tests
spectrophotometric method SOP č.CH-04 (ČSN EN 26777)
6 Drinking, raw, ground, surface and waste water, bathing water Determination of nitrates (NO3-) spectrophotometrically with sulfosalicylic acid and nitrate nitrogen (N-NO3) by calculation
nitrate nitrogen (N-NO3) by calculation (calculated)
Regulated area: Tests
spectrophotometric method with sulfosalicylic acid SOP č.CH-05 (ČSN ISO 7890-3)
7 Drinking, raw, ground, surface and waste water, bathing water Determination of nitrates (NO3-) spectrophotometrically, 2,6-dimethylphenol method, and nitrate nitrogen (N-NO3) by calculation
nitrate nitrogen (N-NO3) by calculation (calculated)
Regulated area: Tests
spectrophotometric method with 2,6-dimethylphenol SOP č.CH-24 (ČSN 75 7455)
8 Drinking, raw, ground and surface water Determination of chlorides by titration, argentometrically with chromate indicator
Regulated area: Tests
argentometric titration with chromate indicator SOP č.CH-06 (ČSN ISO 9297)
9 Drinking, raw, ground and surface water Determination of dissolved sulphates by titration with lead nitrate
Regulated area: Tests
titration with lead nitrate SOP č.CH-07 (ČSN 75 7477)
10 Drinking, raw, ground and surface water Determination of the sum of calcium and magnesium (Ca+Mg) by EDTA titration and determination of magnesium by calculation from the measured values of the sum (Ca+Mg) and Ca
magnesium by calculation from (Ca+Mg) and Ca (calculated)
Regulated area: Tests
EDTA titration SOP č.CH-08 (ČSN ISO 6059)
11 Drinking, raw, ground and surface water Determination of calcium by EDTA titration
Regulated area: Tests
EDTA titration SOP č.CH-09 (ČSN ISO 6058)
12 Drinking, raw, ground and surface water Determination of iron spectrophotometrically with 1,10-phenanthroline
Regulated area: Tests
spectrophotometric method with 1,10-phenanthroline SOP č.CH-11 (ČSN ISO 6332)
13 Drinking, raw, ground and surface water Determination of manganese spectrophotometrically
Regulated area: Tests
spectrophotometric method SOP č.CH-12 (ČSN 83 0520-21:1978; ČSN 83 0530-28:1978)
14 Drinking, raw, ground and surface water Determination of aluminium spectrophotometrically, pyrocatechol violet method
Regulated area: Tests
spectrophotometric pyrocatechol violet method SOP č.CH-13 (ČSN ISO 10566)
15 Drinking, raw, ground, surface and waste water, bathing water Determination of temperature
Regulated area: Tests
SOP č.CH-19 (ČSN ISO 10566)
16 Drinking and raw water, bathing water Determination of free and total chlorine photometrically with N,N'-diethyl-1,4-phenylenediamine, combined chlorine by calculation
combined chlorine by calculation (calculated)
Regulated area: Tests
photometric method with N,N'-diethyl-1,4-phenylenediamine (DPD) SOP č.CH-15 (ČSN EN ISO 7393-2)
17 Drinking, raw, ground and surface water, bathing water Determination of absorbance at a wavelength of 254 nm spectrophotometrically
Regulated area: Tests
spectrophotometric method SOP č.CH-16 (ČSN 75 7360)
18 Drinking, raw, ground and surface water, bathing water Determination of turbidity by nephelometry
Regulated area: Tests
nephelometric method SOP č.CH-17 (ČSN EN ISO 7027-1)
19 Drinking, raw, ground and surface water Determination of electrical conductivity
Regulated area: Tests
SOP č.CH-10 (ČSN EN 27888)
20 Drinking, raw, ground and surface water, bathing water Determination of total organic carbon (TOC) spectrophotometrically
Regulated area: Tests
spectrophotometric method SOP č.CH-31 (ČSN EN 1484)
21 Drinking, raw, ground and surface water Indicative sensory analysis – determination of odour and taste
Regulated area: Tests
sensory analysis SOP č.CH-28 (ČSN 75 7340)
22 Drinking, raw, ground and surface water, bathing water Enumeration of culturable micro-organisms – colony count at 22 °C and 36 °C by inoculation in a nutrient agar culture medium
Regulated area: Tests
inoculation in a nutrient culture medium SOP č.M-06 (ČSN EN ISO 6222)
23 Drinking, raw, ground and surface water, bathing water Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
membrane filtration method SOP č.M-01 (ČSN 75 7835)
24 Drinking, raw, ground and surface water, bathing water Enumeration of Escherichia coli and coliform bacteria by membrane filtration
Regulated area: Tests
membrane filtration method SOP č.M-02 (ČSN EN ISO 9308-1)
25 Drinking, raw, ground and surface water, bathing water Enumeration of enterococci (intestinal enterococci) by membrane filtration
Regulated area: Tests
membrane filtration method SOP č.M-03 (ČSN EN ISO 7899-2)
26 Drinking, raw, ground and surface water Enumeration of Clostridium perfringens (including spores) by membrane filtration
Regulated area: Tests
membrane filtration method SOP č.M-07 (Vyhláška č. 252/2004 Sb., příloha č. 6)
27 Drinking, raw, ground and surface water Determination of the microscopic pattern – number of organisms
Regulated area: Tests
SOP č.HB-01 (ČSN 75 7712)
28 Drinking, raw, ground and surface water Determination of the microscopic pattern – abioseston
Regulated area: Tests
SOP č.HB-01 (ČSN 75 7713)
29 Drinking, raw, ground and surface water, bathing water Enumeration of Pseudomonas aeruginosa by membrane filtration
Regulated area: Tests
membrane filtration method SOP č.M-04 (ČSN EN ISO 16266)
30 Drinking, raw, ground and surface water, bathing water Enumeration of Staphylococcus aureus by membrane filtration
Regulated area: Tests
membrane filtration method SOP č.M-05 (ČSN EN ISO 6888-1)
31 Drinking water, bathing water Enumeration of Legionella bacteria by membrane filtration
Regulated area: Tests
membrane filtration method SOP č.M-08 (ČSN EN ISO 11731)
32 Surface water, waste water Determination of chemical oxygen demand by dichromate (CODCr) by the sealed-tube method
Regulated area: Tests
sealed-tube method SOP č.CH-27 (ČSN ISO 15705)
33 Surface water, waste water Determination of total nitrogen spectrophotometrically after oxidative digestion with peroxodisulphate
Regulated area: Tests
spectrophotometric method SOP č.CH-25 (ČSN EN ISO 11905-1)
34 Drinking, raw, ground, surface and waste water Determination of dissolved inorganic orthophosphates (PO43-) and total phosphorus (Pc) spectrophotometrically with ammonium molybdate, phosphate phosphorus by calculation
phosphate phosphorus by calculation (calculated)
Regulated area: Tests
spectrophotometric method with ammonium molybdate SOP č.CH-26 (ČSN EN ISO 6878, kap. 4 a 7)
35 Surface water, waste water Determination of suspended solids (NL) dried at 105 °C by gravimetry
Regulated area: Tests
gravimetric method SOP č.CH-20 (ČSN EN 872)
36 Surface water, waste water Determination of dissolved solids (RL, RAS) dried at 105 °C and ignited at 550 °C by gravimetry and calculation of loss on ignition
loss on ignition by calculation (calculated)
Regulated area: Tests
gravimetric method SOP č.CH-21 (ČSN 75 7346; ČSN 75 7347)
37 Surface water, waste water Determination of biochemical oxygen demand BOD5 electrochemically
Regulated area: Tests
electrochemical method SOP č.CH-23 (ČSN EN 1899-2; ČSN EN ISO 5815-1)
38 Drinking, raw, ground and surface water, bathing water Determination of oxidation-reduction potential by potentiometry (ORP)
Regulated area: Tests
potentiometric method SOP č.CH-30 (ČSN 75 7367)
39 Drinking, raw, ground and surface water, bathing water Determination of colour spectrophotometrically
Regulated area: Tests
spectrophotometric method SOP č.CH-29 (ČSN EN ISO 7887; TNI 75 7364)
40 Sludge Determination of dry matter at 105 °C and loss on ignition at 550 °C by gravimetry
Regulated area: Tests
gravimetric method SOP č.CH-32 (ČSN EN 12880; ČSN EN 15935)
41 Drinking and raw water Sampling of drinking and raw water
Regulated area: Sampling
SOP č.V-01 (ČSN ISO 5667-5; ČSN ISO 5667-11; ČSN EN ISO 19458; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14)
42 Surface water, waste water Sampling of waste and surface water – manual sampling and sampling with an automatic sampler
Regulated area: Sampling
SOP č.V-02 (ČSN EN ISO 5667-6; ČSN ISO 5667-10; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14)
43 Liquid and solid sludge, screenings Sampling of sludge from wastewater and water treatment plants
Regulated area: Sampling
SOP č.V-03 (ČSN EN ISO 5667-13; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15)
44 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP č.V-04 (Vyhláška č. 238/2011 Sb.; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458)

Reference standards (99)

SOP č.CH-01
SOP č.CH-02
SOP č.CH-03
SOP č.CH-04
SOP č.CH-05
SOP č.CH-06
SOP č.CH-07
SOP č.CH-08
SOP č.CH-09
SOP č.CH-10
SOP č.CH-11
SOP č.CH-12
SOP č.CH-13
SOP č.CH-15
SOP č.CH-16
SOP č.CH-17
SOP č.CH-18
SOP č.CH-19
SOP č.CH-20
SOP č.CH-21
SOP č.CH-23
SOP č.CH-24
SOP č.CH-25
SOP č.CH-26
SOP č.CH-27
SOP č.CH-28
SOP č.CH-29
SOP č.CH-30
SOP č.CH-31
SOP č.CH-32
SOP č.HB-01
SOP č.M-01
SOP č.M-02
SOP č.M-03
SOP č.M-04
SOP č.M-05
SOP č.M-06
SOP č.M-07
SOP č.M-08
SOP č.V-01
SOP č.V-02
SOP č.V-03
SOP č.V-04
TNI 75 7364
Vyhláška č. 238/2011 Sb.
Vyhláška č. 252/2004 Sb., příloha č. 6
ČSN 75 7340
ČSN 75 7346
ČSN 75 7347
ČSN 75 7360
ČSN 75 7367
ČSN 75 7372
ČSN 75 7373
ČSN 75 7455
ČSN 75 7477
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN 83 0520-21:1978
ČSN 83 0530-28:1978
ČSN EN 12880
ČSN EN 1484
ČSN EN 15935
ČSN EN 1899-2
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 11731
ČSN EN ISO 11905-1
ČSN EN ISO 16266
ČSN EN ISO 19458
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878, kap. 4 a 7
ČSN EN ISO 6888-1
ČSN EN ISO 7027-1
ČSN EN ISO 7393-2
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 9308-1
ČSN EN ISO 9963-1
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 15705
ČSN ISO 5667-10
ČSN ISO 5667-11
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 9297

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1430