🇨🇿 Středočeské vodárny, a.s. PL

ČIA 1429 • Kladno, Czech Republic • 63 methods

Water & wastewaterMicrobiologyEnvironment

Středočeské vodárny, a.s. is a laboratory accredited by ČIA under number 1429 (Kladno, Czech Republic). Its accreditation scope covers 63 test methods in the following areas: Water & wastewater, Microbiology, Environment. Test objects include: Drinking, bottled, hot, ground, surface and raw water, Waste, ground, raw and surface water, Drinking, bottled, hot, ground, surface, raw and waste water, Sludges.

At a glance

  • Accreditation number: ČIA 1429
  • Methods in scope: 63
  • Types of test objects: 11
  • City: Kladno, Czech Republic
  • Valid until: 12-04-2027
Accreditation number
1429
Accreditation body
ČIA
Address
U Vodojemu 3085, 272 80 Kladno
City
Kladno, Czech Republic
Division
Dział Laboratoriów Wody Pitnej i Ścieków
Valid until
12-04-2027

What this laboratory tests (11)

Certificate information

Certificate date
12.03.2026

Accreditation scope — test methods (63)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Drinking, bottled, hot, ground, surface and raw water Determination of turbidity by nephelometry
Regulated area: Tests
SOP č. 11 (ČSN EN ISO 7027-1)
2 Drinking, bottled, hot, ground, surface, raw and waste water Determination of electrical conductivity
Regulated area: Tests
SOP č. 12 (ČSN EN 27888)
3 Drinking, bottled, hot, ground, surface, raw and waste water and sludges Determination of pH by potentiometry
Regulated area: Tests
SOP č. 13 (ČSN ISO 10523)
4 Drinking, bottled, hot, ground, surface and raw water Determination of iron by spectrophotometry
Regulated area: Tests
SOP č. 14 (ČSN ISO 6332)
5 Drinking, bottled, hot, ground, surface and raw water Determination of ammonium ions by spectrophotometry
Regulated area: Tests
SOP č. 16 (ČSN ISO 7150-1)
6 Drinking, bottled, hot, ground, surface, raw and waste water Determination of temperature
Regulated area: Tests
SOP č. 21 (ČSN 75 7342)
7 Drinking, bottled, hot, ground, surface and raw water Determination of aluminium by spectrophotometry
Regulated area: Tests
SOP č. 22 (ČSN ISO 10566)
8 Drinking, bottled, hot, ground, surface and raw water Determination of absorbance at a wavelength of 254 nm by spectrophotometry
Regulated area: Tests
SOP č. 23 (ČSN 75 7360)
9 Drinking, bottled, hot, ground, surface and raw water Determination of total phosphorus by spectrophotometry
Regulated area: Tests
SOP č. 5 (ČSN EN ISO 6878)
10 Drinking, bottled, hot, ground, surface and raw water Determination of humic substances by spectrophotometry after extraction
Regulated area: Tests
SOP č. 26 (ČSN 75 7536)
11 Drinking, bottled, hot, ground, surface and raw water Determination of CODMn by permanganate titration
Regulated area: Tests
SOP č. 27 (ČSN EN ISO 8467)
12 Drinking water Determination of free and total active chlorine by spectrophotometry and combined chlorine by calculation – commercial HACH analytical kit
free chlorine total chlorine
combined chlorine (calculated)
Regulated area: Tests
SOP č. 28 (ČSN EN ISO 7393-2; návod firmy HACH)
13 Drinking, bottled, hot, ground, surface and raw water Determination of the sum of calcium and magnesium by titration
Regulated area: Tests
SOP č. 29 (ČSN ISO 6059)
14 Drinking, bottled, hot, ground, surface and raw water Determination of colour by spectrophotometry
Regulated area: Tests
SOP č. 18 (ČSN EN ISO 7887; TNI 757364)
15 Drinking, bottled, hot, ground, surface and raw water Determination of acid neutralising capacity (ANC-4.5) by acid-base titration
Regulated area: Tests
SOP č. 59 (ČSN EN ISO 9963-1)
16 Drinking, bottled, hot, ground, surface and raw water Determination of base neutralising capacity (BNC-8.3) by acid-base titration and calculation of the forms of carbon dioxide
forms of carbon dioxide (calculated)
Regulated area: Tests
SOP č. 60 (ČSN 75 7372; ČSN 75 7373)
17 Drinking, bottled, hot, ground, surface and raw water Determination of odour and taste by sensory analysis
Regulated area: Tests
SOP č. 7 (ČSN 75 7340; ČSN EN 1622)
18 Drinking, bottled, hot, ground, surface and raw water Determination of boron by spectrophotometry
Regulated area: Tests
SOP č. 38 (ČSN ISO 9390)
19 Drinking, bottled, hot, ground, surface, raw and waste water Determination of TOC by spectrophotometry – commercial HACH analytical kit
Regulated area: Tests
SOP č. 74 (ČSN EN 1484; návod firmy HACH)
20 Drinking, bottled, hot, ground, surface and raw water Determination of anions by ion liquid chromatography
fluorides nitrites nitrates phosphates chlorides sulphates chlorites chlorates bromates
Regulated area: Tests
SOP č. 86 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061)
21 Drinking, bottled, hot, ground, surface and raw water Determination of volatile organic compounds by gas chromatography with FID after SPME
vinyl chloride 1,2-dichloroethane tetrachloromethane benzene trichloroethene tetrachloroethene trihalomethanes (chloroform, bromodichloromethane, dibromochloromethane, bromoform)
Regulated area: Tests
SOP č. 51 (ČSN EN ISO 10301)
22 Drinking, bottled, hot, ground, surface, raw and waste water Determination of hydrocarbons C10-C40 by gas chromatography with FID after solvent extraction
Regulated area: Tests
SOP č. 77 (ČSN EN ISO 9377-2)
23 Drinking, bottled, hot, ground, surface, raw and waste water Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with fluorescence detector
benzo(b)fluoranthene benzo(k)fluoranthene benzo(ghi)perylene benzo(a)pyrene fluoranthene indeno(1,2,3-cd)pyrene
Regulated area: Tests
SOP č. 80 (ČSN EN ISO 17993)
24 Ground and surface water Determination of thermotolerant (faecal) coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
SOP č. 31 (ČSN 75 7835)
25 Drinking, bottled, hot, ground, surface and raw water Determination of intestinal enterococci by membrane filtration
Regulated area: Tests
SOP č. 32 (ČSN EN ISO 7899-2)
26 Drinking, bottled, hot, ground, surface and raw water Enumeration of culturable micro-organisms at 22 °C and 36 °C by direct inoculation in a nutrient agar culture medium
Regulated area: Tests
SOP č. 52 (ČSN EN ISO 6222)
27 Drinking, bottled, hot, ground, surface and raw water Determination of coliform bacteria and Escherichia coli by the Colilert-18/Quanti-Tray method
Regulated area: Tests
SOP č. 65 (ČSN EN ISO 9308-2; návod setu Colilert 18/QTray)
28 Drinking, bottled, hot, ground, surface and raw water Determination of Clostridium perfringens (including spores) by membrane filtration
Regulated area: Tests
SOP č. 64 A (Vyhláška č. 252/2004 Sb., Příloha č. 6)
29 Drinking, bottled, hot, ground, surface and raw water Determination of coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
SOP č. 30 (ČSN EN ISO 9308-1)
30 Drinking, bottled, hot, ground, surface and raw water Determination of Pseudomonas aeruginosa by membrane filtration
Regulated area: Tests
SOP č. 37 (ČSN EN ISO 16266)
31 Drinking, bottled, hot, ground, surface and raw water Determination of Clostridium perfringens (including spores) by membrane filtration
Regulated area: Tests
SOP č. 64 B (ČSN EN ISO 14189)
32 Drinking, bottled, hot, ground, surface and raw water Determination of bioseston by microscopy
Regulated area: Tests
SOP č. 35 A (ČSN 75 7712)
33 Drinking, bottled, hot, ground, surface and raw water Determination of abioseston by microscopy
Regulated area: Tests
SOP č. 35 B (ČSN 75 7713)
34 Drinking, bottled, hot, ground, surface and raw water Determination of gross alpha activity concentration with a ZnS (Ag) scintillator
Regulated area: Tests
SOP č. 46 (ČSN 75 7611)
35 Drinking, bottled, hot, ground, surface and raw water Determination of gross beta activity concentration after evaporation with a proportional detector
Regulated area: Tests
SOP č. 47 (ČSN 75 7612)
36 Drinking, bottled, hot, ground, surface and raw water Determination of radium-226 activity concentration by the scintillation emanometric method
Regulated area: Tests
SOP č. 48 (ČSN 75 7623)
37 Drinking, bottled, hot, ground, surface and raw water Determination of radon-222 activity concentration by the scintillation emanometric method
Regulated area: Tests
SOP č. 49 (ČSN 75 7624)
38 Drinking, bottled, hot, ground, surface and raw water Determination of uranium by spectrophotometry
Regulated area: Tests
SOP č. 50 (ČSN 75 7614)
39 Waste, ground, raw and surface water Determination of CODCr by spectrophotometry – commercial HACH analytical kit
Regulated area: Tests
SOP č. 1 (ČSN ISO 15705; návod firmy HACH)
40 Waste, ground, raw and surface water Determination of ammonium ions and ammonium nitrogen by spectrophotometry
ammonium ions ammonium nitrogen
Regulated area: Tests
SOP č. 2 (ČSN ISO 7150-1)
41 Waste, ground, raw and surface water Determination of suspended solids by gravimetry
Regulated area: Tests
SOP č. 3 (ČSN EN 872)
42 Waste, ground, raw and surface water Determination of dissolved solids and residue on ignition (RAS) by gravimetry
dissolved solids residue on ignition (RAS)
Regulated area: Tests
SOP č. 4 (ČSN 75 7347)
43 Waste, ground, raw and surface water Determination of biochemical oxygen demand BOD5 with a membrane probe
Regulated area: Tests
SOP č. 6 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN EN ISO 5814)
44 Waste, ground, raw and surface water Determination of nitrites and nitrite nitrogen by spectrophotometry and calculation of inorganic nitrogen
nitrites nitrite nitrogen
inorganic nitrogen (calculated)
Regulated area: Tests
SOP č. 8 (ČSN EN 26777)
45 Waste, ground, raw and surface water Determination of nitrates and nitrate nitrogen by spectrophotometry
nitrates nitrate nitrogen
Regulated area: Tests
SOP č. 9 (ČSN ISO 7890-3)
46 Waste, ground, raw and surface water Determination of phosphates and total phosphorus by spectrophotometry – commercial HACH analytical kit
phosphates total phosphorus
Regulated area: Tests
SOP č. 83 (ČSN EN ISO 6878; návod firmy HACH)
47 Waste, ground, raw and surface water Determination of steam-volatile monohydric phenols by spectrophotometry after distillation
Regulated area: Tests
SOP č. 55 (ČSN ISO 6439)
48 Waste, ground, raw and surface water Determination of total fats and oils by gravimetry
Regulated area: Tests
SOP č. 68 (ČSN 75 7509)
49 Waste, ground, raw and surface water Determination of dissolved oxygen with a membrane probe
Regulated area: Tests
SOP č. 17 (ČSN EN ISO 5814)
50 Sludges Determination of sludge volume after settling and calculation of the sludge volume index
sludge volume after settling
sludge volume index (calculated)
Regulated area: Tests
SOP č. 70 (ČSN EN 14702-1)
51 Sludges Determination of total dried solids and residue on ignition by gravimetry
Regulated area: Tests
SOP č. 71 (ČSN EN 12880)
52 Sludges Determination of suspended solids and residue on ignition by gravimetry
Regulated area: Tests
SOP č. 73 (ČSN EN 872; ČSN 75 7350)
53 Waste, ground, raw and surface water Determination of total nitrogen by spectrophotometry – commercial HACH analytical kit
Regulated area: Tests
SOP č. 82 (ČSN EN ISO 11905-1; návod firmy HACH)
54 Ground, raw, drinking and surface water Determination of anionic surfactants (MBAS) – commercial HACH analytical kit
Regulated area: Tests
SOP č. 84 (ČSN EN 903; návod firmy HACH)
55 Drinking, bottled, hot, ground, surface, raw and waste water Determination of elements by ICP-OES
cadmium lead copper chromium nickel beryllium arsenic antimony selenium manganese sodium potassium magnesium calcium zinc
Regulated area: Tests
SOP č. 15 (ČSN EN ISO 11885; ČSN EN ISO 15587-2)
56 Drinking, bottled, hot, ground, surface, raw and waste water Determination of mercury by ICP-OES using the cold vapour technique
Regulated area: Tests
SOP č. 19 (ČSN EN 16175-1; ČSN EN ISO 15587-2; ČSN EN ISO 11885)
57 Drinking, bottled, hot, ground, surface and raw water Determination of total cyanides after distillation by spectrophotometry – commercial HACH analytical kit
Regulated area: Tests
SOP č. 20 (ČSN 75 7415; návod firmy HACH)
58 Waste, ground, raw and surface water Determination of ammonium ions and ammonium nitrogen by spectrophotometry – commercial HACH analytical kit
ammonium ions ammonium nitrogen
Regulated area: Tests
SOP č. 25 (ČSN ISO 23695; návod firmy HACH)
59 Sludge gas Determination of CO2 and CH4 by infrared spectrometry
carbon dioxide (CO2) methane (CH4)
Regulated area: Tests
SOP č. 75 (Manuál analyzátoru BIOGAS 5000)
60 Sludge gas Determination of O2 and H2S electrochemically
oxygen (O2) hydrogen sulphide (H2S)
Regulated area: Tests
SOP č. 75 (Manuál analyzátoru BIOGAS 5000)
61 Drinking water and water used for the production of drinking water Sampling of drinking water and water used for its production (manual sampling)
Regulated area: Sampling
DSPK, C.30 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-16; ČSN ISO 5667-5; ČSN ISO 5667-11, čl. 5.3.1.1; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
62 Waste water Sampling of waste water (manual sampling and sampling with an automatic sampler)
Regulated area: Sampling
DSPK, C.33 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN ISO 5667-11, čl. 5.3.1.1; ČSN EN ISO 5667-14)
63 Sludges Sampling of sludges (manual sampling)
Regulated area: Sampling
DSPK, C.24 (ČSN EN ISO 5667-13; ČSN EN ISO 5667-15)

Reference standards (138)

DSPK, C.24
DSPK, C.30
DSPK, C.33
Manuál analyzátoru BIOGAS 5000
SOP č. 1
SOP č. 11
SOP č. 12
SOP č. 13
SOP č. 14
SOP č. 15
SOP č. 16
SOP č. 17
SOP č. 18
SOP č. 19
SOP č. 2
SOP č. 20
SOP č. 21
SOP č. 22
SOP č. 23
SOP č. 25
SOP č. 26
SOP č. 27
SOP č. 28
SOP č. 29
SOP č. 3
SOP č. 30
SOP č. 31
SOP č. 32
SOP č. 35 A
SOP č. 35 B
SOP č. 37
SOP č. 38
SOP č. 4
SOP č. 46
SOP č. 47
SOP č. 48
SOP č. 49
SOP č. 5
SOP č. 50
SOP č. 51
SOP č. 52
SOP č. 55
SOP č. 59
SOP č. 6
SOP č. 60
SOP č. 64 A
SOP č. 64 B
SOP č. 65
SOP č. 68
SOP č. 7
SOP č. 70
SOP č. 71
SOP č. 73
SOP č. 74
SOP č. 75
SOP č. 77
SOP č. 8
SOP č. 80
SOP č. 82
SOP č. 83
SOP č. 84
SOP č. 86
SOP č. 9
TNI 757364
Vyhláška č. 252/2004 Sb., Příloha č. 6
návod firmy HACH
návod setu Colilert 18/QTray
ČSN 75 7340
ČSN 75 7342
ČSN 75 7347
ČSN 75 7350
ČSN 75 7360
ČSN 75 7372
ČSN 75 7373
ČSN 75 7415
ČSN 75 7509
ČSN 75 7536
ČSN 75 7611
ČSN 75 7612
ČSN 75 7614
ČSN 75 7623
ČSN 75 7624
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN EN 12880
ČSN EN 14702-1
ČSN EN 1484
ČSN EN 16175-1
ČSN EN 1622
ČSN EN 1899-2
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN 903
ČSN EN ISO 10301
ČSN EN ISO 10304-1
ČSN EN ISO 10304-4
ČSN EN ISO 11885
ČSN EN ISO 11905-1
ČSN EN ISO 14189
ČSN EN ISO 15061
ČSN EN ISO 15587-2
ČSN EN ISO 16266
ČSN EN ISO 17993
ČSN EN ISO 19458
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-16
ČSN EN ISO 5667-3
ČSN EN ISO 5814
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878
ČSN EN ISO 7027-1
ČSN EN ISO 7393-2
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9308-2
ČSN EN ISO 9377-2
ČSN EN ISO 9963-1
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 15705
ČSN ISO 23695
ČSN ISO 5667-10
ČSN ISO 5667-11, čl. 5.3.1.1
ČSN ISO 5667-5
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 6439
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 9390

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1429