🇨🇿 Vodovody a kanalizace Kroměříž, a.s. PL
Water & wastewaterMicrobiology
Vodovody a kanalizace Kroměříž, a.s. is a laboratory accredited by ČIA under number 1415 (Kroměříž, Czech Republic). Its accreditation scope covers 45 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Drinking, surface, ground water, Waste, surface, ground water, Drinking, surface, ground, waste water, Waste water, surface water. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Gravimetric method.
At a glance
- Accreditation number: ČIA 1415
- Methods in scope: 45
- Types of test objects: 9
- Techniques used: 19
- City: Kroměříž, Czech Republic
- Valid until: 29-10-2026
- Accreditation number
- 1415
- Accreditation body
- ČIA
- Address
- Kojetínská 3666/64, 767 01 Kroměříž
- City
- Kroměříž, Czech Republic
- Division
- Laboratorium wód pitnych i ścieków
- Valid until
- 29-10-2026
What this laboratory tests (9)
- Drinking, surface, ground water — 18 methods
- Waste, surface, ground water — 9 methods
- Drinking, surface, ground, waste water — 6 methods
- Waste water, surface water — 6 methods
- Drinking water — 2 methods
- Disinfected drinking water — 1 method
- Ground water — 1 method
- Surface water — 1 method
- Waste water — 1 method
Analytical techniques used (19)
- Spectrophotometric method — 7 methods
- Membrane filtration method — 5 methods
- Gravimetric method — 4 methods
- Titration — 3 methods
- EDTA titrimetric method — 2 methods
- Potentiometric method — 2 methods
- Spectrophotometric method – Hach set — 2 methods
- AMA mercury analyser — 1 method
- Argentometric method — 1 method
- Colilert method (MPN) — 1 method
- Coulometric method — 1 method
- Cultivation method — 1 method
- Dilution method, oxygen electrode (electrochemical method) — 1 method
- Electrothermal atomic absorption spectrometry (ETAAS) — 1 method
- Flame atomic absorption spectrometry (FAAS) — 1 method
- and 4 more
Laboratory sections (2)
- Drinking water laboratory — 29 methods
- Waste water laboratory — 16 methods
Laboratory locations
- Laboratorium wód pitnych — Kojetínská 2833
- Laboratorium ścieków — Dolnozahradská 3300
Certificate information
- Certificate date
- 29.10.2021
Accreditation scope — test methods (45)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Drinking water laboratory | |||||
| 1 | Drinking, surface, ground water | Determination of culturable microorganisms a) at 22 °C b) at 36 °C – by cultivation Culturable microorganisms at 22 °C Culturable microorganisms at 36 °C Regulated area: Drinking water laboratory – Tests |
Cultivation method | SOP 103 (ČSN EN ISO 6222) | |
| 2 | Drinking, surface, ground water | Determination of coliform bacteria – membrane filtration method Regulated area: Drinking water laboratory – Tests |
Membrane filtration method | SOP 104 (ČSN 75 7837) | |
| 3 | Drinking, surface, ground water | Determination of thermotolerant bacteria and Escherichia coli – membrane filtration method Regulated area: Drinking water laboratory – Tests |
Membrane filtration method | SOP 105 (ČSN 75 7835) | |
| 4 | Disinfected drinking water | Determination of coliform bacteria and Escherichia coli – membrane filtration method Regulated area: Drinking water laboratory – Tests |
Membrane filtration method | SOP 106 (ČSN EN ISO 9308-1:2015) | |
| 5 | Drinking, surface, ground water | Determination of intestinal enterococci – membrane filtration method Regulated area: Drinking water laboratory – Tests |
Membrane filtration method | SOP 107 (ČSN EN ISO 7899-2) | |
| 6 | Drinking, surface, ground water | Determination of Clostridium perfringens – membrane filtration method Regulated area: Drinking water laboratory – Tests |
Membrane filtration method | SOP 108 (dle Vyhl. 252/2004 Sb. v platném znění) | |
| 7 | Drinking water | Determination of coliform bacteria and Escherichia coli by the Colilert method Regulated area: Drinking water laboratory – Tests |
Colilert method (MPN) | SOP 111 (standardní laboratorní postup firmy IDEXX) | |
| 8 | Drinking, surface, ground water | Determination of temperature Regulated area: Drinking water laboratory – Tests |
SOP 121 (ČSN 75 7342:2013) | ||
| 9 | Drinking, surface, ground water | Determination of electrical conductivity Regulated area: Drinking water laboratory – Tests |
SOP 124 (ČSN EN 27888) | ||
| 10 | Drinking, surface, ground water | Determination of pH potentiometrically Regulated area: Drinking water laboratory – Tests |
Potentiometric method | SOP 125 (ČSN ISO 10523) | |
| 11 | Drinking, surface, ground water | Determination of chemical oxygen demand (CODMn) by titration Regulated area: Drinking water laboratory – Tests |
Titration | SOP 127 (ČSN EN ISO 8467) | |
| 12 | Drinking, surface, ground water | Determination of calcium by the EDTA titrimetric method and calculation of magnesium from measured values Calcium (Ca) Magnesium (Mg) (calculated) (calculated) Regulated area: Drinking water laboratory – Tests |
EDTA titrimetric method | SOP 128 (ČSN ISO 6058) | |
| 13 | Drinking, surface, ground water | Determination of the sum of calcium and magnesium by the EDTA titrimetric method Regulated area: Drinking water laboratory – Tests |
EDTA titrimetric method | SOP 128a (ČSN ISO 6059) | |
| 14 | Drinking, surface, ground water | Determination of ammonium ions spectrophotometrically Regulated area: Drinking water laboratory – Tests |
Spectrophotometric method | SOP 129 (ČSN ISO 7150-1) | |
| 15 | Drinking, surface, ground water | Determination of nitrites spectrophotometrically Regulated area: Drinking water laboratory – Tests |
Spectrophotometric method | SOP 130 (ČSN EN 26777) | |
| 16 | Drinking, surface, ground water | Determination of nitrates spectrophotometrically Regulated area: Drinking water laboratory – Tests |
Spectrophotometric method | SOP 131 (ČSN ISO 7890-3) | |
| 17 | Drinking, surface, ground water | Determination of chlorides argentometrically Regulated area: Drinking water laboratory – Tests |
Argentometric method | SOP 132 (ČSN ISO 9297) | |
| 18 | Drinking, surface, ground water | Determination of sulphates by titration Regulated area: Drinking water laboratory – Tests |
Titration | SOP 133 (TNV 75 7477) | |
| 19 | Drinking, surface, ground water | Determination of acid neutralising capacity by titration Regulated area: Drinking water laboratory – Tests |
Titration | SOP 135 (ČSN EN ISO 9963-1) | |
| 20 | Drinking, surface, ground water | Determination of dissolved solids gravimetrically Regulated area: Drinking water laboratory – Tests |
Gravimetric method | SOP 144 (ČSN 75 7346) | |
| 21 | Drinking, surface, ground, waste water | Determination of metals (Zn, Cu, Ni, Pb, Ag, Co, Cd, Cr, Fe, Mn) by flame atomic absorption spectrometry (AAS) Zinc (Zn) Copper (Cu) Nickel (Ni) Lead (Pb) Silver (Ag) Cobalt (Co) Cadmium (Cd) Chromium (Cr) Iron (Fe) Manganese (Mn) Regulated area: Drinking water laboratory – Tests |
Flame atomic absorption spectrometry (FAAS) | SOP 147 (ČSN EN ISO 5961) | |
| 22 | Drinking, surface, ground, waste water | Determination of mercury on the AMA analyser Mercury (Hg) Regulated area: Drinking water laboratory – Tests |
AMA mercury analyser | SOP 148 (ČSN 75 7440) | |
| 23 | Drinking, surface, ground, waste water | Determination of metals (As, Se, Ba, Be, Mo, Sb, V) by AAS with electrothermal atomisation Arsenic (As) Selenium (Se) Barium (Ba) Beryllium (Be) Molybdenum (Mo) Antimony (Sb) Vanadium (V) Regulated area: Drinking water laboratory – Tests |
Electrothermal atomic absorption spectrometry (ETAAS) | SOP 146 (ČSN EN ISO 15586) | |
| 24 | Drinking, surface, ground, waste water | Determination of volatile organic compounds (VOC) by gas chromatography with MS detector, sum of trihalomethanes and BTEX calculated from measured values Vinyl chloride 1,1-Dichloroethene Dichloromethane trans-1,2-Dichloroethene Chloroform 1,2-Dichloroethane Tetrachloromethane Benzene Trichloroethene Bromodichloromethane Toluene Tetrachloroethene Dibromochloromethane Chlorobenzene Ethylbenzene m-Xylene p-Xylene o-Xylene Styrene Bromoform 1,2-Dichlorobenzene 1,3-Dichlorobenzene 1,4-Dichlorobenzene Sum of trihalomethanes (calculated) (calculated), BTEX (calculated) (calculated) Regulated area: Drinking water laboratory – Tests |
Gas chromatography with mass spectrometric detection (GC-MS) | SOP 180 (ČSN EN ISO 10301) | |
| 25 | Drinking, surface, ground, waste water | Determination of polycyclic aromatic hydrocarbons (PAH) by liquid chromatography with fluorescence detector and sum of PAH calculated from measured values Naphthalene Acenaphthene Fluorene Phenanthrene Anthracene Fluoranthene Pyrene Benzo[a]anthracene Chrysene Benzo[b]fluoranthene Benzo[k]fluoranthene Benzo[a]pyrene Dibenzo[a,h]anthracene Benzo[ghi]perylene Indeno[1,2,3-cd]pyrene Sum of PAH (calculated) (calculated) Regulated area: Drinking water laboratory – Tests |
Liquid chromatography with fluorescence detection (HPLC-FLD) | SOP 181 (ČSN 75 7554, ČSN EN ISO 17993) | |
| 26 | Drinking, surface, ground, waste water | Determination of hydrocarbons C10-C40 by gas chromatography with FID detector Regulated area: Drinking water laboratory – Tests |
Gas chromatography with flame ionisation detection (GC-FID) | SOP 182 (ČSN EN ISO 9377-2, TNI 75 7507) | |
| 27 | Drinking water | Sampling of drinking water Regulated area: Drinking water laboratory – Sampling |
SOP 171 (ČSN EN ISO 5667 - 3, ČSN ISO 5667 - 5, ČSN EN ISO 19458) | ||
| 28 | Surface water | Sampling of surface water Regulated area: Drinking water laboratory – Sampling |
SOP 172 (ČSN EN ISO 5667 - 3, ČSN ISO 5667 - 4, ČSN EN ISO 5667 - 6, ČSN EN ISO 19458) | ||
| 29 | Ground water | Sampling of ground water (manual sampling + pumped sampling) Regulated area: Drinking water laboratory – Sampling |
SOP 171a (ČSN EN ISO 5667 - 3, ČSN ISO 5667 - 11, ČSN EN ISO 19458) | ||
| Waste water laboratory | |||||
| 30 | Waste water, surface water | Determination of electrical conductivity Regulated area: Waste water laboratory – Tests |
SOP 201 (ČSN EN 27888) | ||
| 31 | Waste water, surface water | Determination of pH potentiometrically Regulated area: Waste water laboratory – Tests |
Potentiometric method | SOP 202 (ČSN ISO 10523) | |
| 32 | Waste, surface, ground water | Determination of ammonium ions spectrophotometrically, expressed as NH4+, and calculation of ammoniacal nitrogen from measured values Ammonium ions (NH4+) Ammoniacal nitrogen (N-NH4+) (calculated) (calculated) Regulated area: Waste water laboratory – Tests |
Spectrophotometric method | SOP 203 (ČSN ISO 7150-1, ČSN ISO 5664) | |
| 33 | Waste water, surface water | Determination of nitrites spectrophotometrically, expressed as NO2-, and calculation of nitrite nitrogen from measured values Nitrites (NO2-) Nitrite nitrogen (N-NO2-) (calculated) (calculated) Regulated area: Waste water laboratory – Tests |
Spectrophotometric method | SOP 204 (ČSN EN 26777) | |
| 34 | Waste water, surface water | Determination of nitrates spectrophotometrically, expressed as NO3-, and calculation of nitrate nitrogen from measured values Nitrates (NO3-) Nitrate nitrogen (N-NO3-) (calculated) (calculated) Regulated area: Waste water laboratory – Tests |
Spectrophotometric method | SOP 205 (ČSN ISO 7890-3) | |
| 35 | Waste, surface, ground water | Determination of chemical oxygen demand (CODCr) spectrophotometrically Regulated area: Waste water laboratory – Tests |
Spectrophotometric method | SOP 206 (ČSN ISO 15705) | |
| 36 | Waste, surface, ground water | Determination of dissolved inorganic salts gravimetrically Regulated area: Waste water laboratory – Tests |
Gravimetric method | SOP 207 (ČSN 75 7347) | |
| 37 | Waste, surface, ground water | Determination of suspended solids gravimetrically Regulated area: Waste water laboratory – Tests |
Gravimetric method | SOP 208 (ČSN EN 872) | |
| 38 | Waste, surface, ground water | Determination of total phosphorus spectrophotometrically – Hach set Regulated area: Waste water laboratory – Tests |
Spectrophotometric method – Hach set | SOP 209 (návod firmy Hach, ČSN EN ISO 6878) | |
| 39 | Waste, surface, ground water | Determination of dissolved solids gravimetrically Regulated area: Waste water laboratory – Tests |
Gravimetric method | SOP 210 (ČSN 75 7346) | |
| 40 | Waste, surface, ground water | Determination of biochemical oxygen demand (BODn) by the dilution method with an oxygen electrode Regulated area: Waste water laboratory – Tests |
Dilution method, oxygen electrode (electrochemical method) | SOP 211 (ČSN EN ISO 5815-1, ČSN EN 1899 - 2, ČSN EN 25814) | |
| 41 | Waste, surface, ground water | Determination of dissolved oxygen by luminescence Regulated area: Waste water laboratory – Tests |
Luminescence method (optical) | SOP 212 (ČSN EN 25814) | |
| 42 | Waste, surface, ground water | Determination of adsorbable organic halogens (AOX) coulometrically Regulated area: Waste water laboratory – Tests |
Coulometric method | SOP 213 (ČSN EN ISO 9562) | |
| 43 | Waste water, surface water | Determination of total nitrogen spectrophotometrically – Hach set Regulated area: Waste water laboratory – Tests |
Spectrophotometric method – Hach set | SOP 214 (návod firmy Hach, ČSN EN ISO 11905 - 1) | |
| 44 | Waste water, surface water | Determination of temperature Regulated area: Waste water laboratory – Tests |
SOP 121 (ČSN 75 7342:2013) | ||
| 45 | Waste water | Sampling of waste water Regulated area: Waste water laboratory – Sampling |
SOP 251 (ČSN EN ISO 5667-3, ČSN ISO 5667-10) | ||
Reference standards (91)
SOP 103
SOP 104
SOP 105
SOP 106
SOP 107
SOP 108
SOP 111
SOP 121
SOP 124
SOP 125
SOP 127
SOP 128
SOP 128a
SOP 129
SOP 130
SOP 131
SOP 132
SOP 133
SOP 135
SOP 144
SOP 146
SOP 147
SOP 148
SOP 171
SOP 171a
SOP 172
SOP 180
SOP 181
SOP 182
SOP 201
SOP 202
SOP 203
SOP 204
SOP 205
SOP 206
SOP 207
SOP 208
SOP 209
SOP 210
SOP 211
SOP 212
SOP 213
SOP 214
SOP 251
TNI 75 7507
TNV 75 7477
dle Vyhl. 252/2004 Sb. v platném znění
návod firmy Hach
standardní laboratorní postup firmy IDEXX
ČSN 75 7342:2013
ČSN 75 7346
ČSN 75 7347
ČSN 75 7440
ČSN 75 7554
ČSN 75 7835
ČSN 75 7837
ČSN EN 1899 - 2
ČSN EN 25814
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 10301
ČSN EN ISO 11905 - 1
ČSN EN ISO 15586
ČSN EN ISO 17993
ČSN EN ISO 19458
ČSN EN ISO 5667 - 3
ČSN EN ISO 5667 - 6
ČSN EN ISO 5667-3
ČSN EN ISO 5815-1
ČSN EN ISO 5961
ČSN EN ISO 6222
ČSN EN ISO 6878
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1:2015
ČSN EN ISO 9377-2
ČSN EN ISO 9562
ČSN EN ISO 9963-1
ČSN ISO 10523
ČSN ISO 15705
ČSN ISO 5664
ČSN ISO 5667 - 11
ČSN ISO 5667 - 4
ČSN ISO 5667 - 5
ČSN ISO 5667-10
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 9297