🇨🇿 Zdravotní ústav se sídlem v Ostravě PL

ČIA 1393 • Ostrava, Czech Republic • 805 methods

Water & wastewaterEnvironmentMicrobiologyFood & beveragesPharma & cosmeticsConstructionMaterials & polymers

Zdravotní ústav se sídlem v Ostravě is a laboratory accredited by ČIA under number 1393 (Ostrava, Czech Republic). Its accreditation scope covers 805 test methods in the following areas: Water & wastewater, Environment, Microbiology, Food & beverages. Test objects include: Foods, Working and non-working environment, Workplace air, Water, bottled water, extracts.

At a glance

  • Accreditation number: ČIA 1393
  • Methods in scope: 805
  • Types of test objects: 102
  • City: Ostrava, Czech Republic
  • Valid until: 10-07-2028
Accreditation number
1393
Accreditation body
ČIA
Address
Partyzánské náměstí 2633/7, Moravská Ostrava, 702 00 Ostrava
City
Ostrava, Czech Republic
Division
Centrum Laboratoriów Higienicznych
Valid until
10-07-2028

What this laboratory tests (102)

Laboratory sections (17)

Laboratory locations

Certificate information

Certificate date
01.09.2026

Accreditation scope — test methods (805)

No. Test object Methodology / Parameters Technique Reference document
Ostrava
1 Drinking, ground, surface and bathing water, extracts Determination of absorbance
Regulated area: 1 Basic chemistry
SOP OV 001 (ČSN 75 7360)
2 Water, bottled water, extracts Determination of ammonium by spectrophotometry and ammonia nitrogen by calculation from measured values
ammonia nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 002 (ČSN ISO 7150-1)
3 Waste, solid samples Determination of ammonium by spectrophotometry and ammonia nitrogen by calculation from measured values
ammonia nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 002.01 (JPP ÚKZÚZ, Analýza půd III; ČSN ISO 7150-1)
4 Water, purified water, bottled water, extracts Determination of anions by ion chromatography (conductivity detection)
fluorides chlorides nitrites nitrates phosphates sulphates bromates chlorites chlorates
nitrite nitrogen (calculated), nitrate nitrogen (calculated), phosphorus pentoxide (P2O5) (calculated), sum of chlorates and chlorites (calculated)
Regulated area: 1 Basic chemistry
SOP OV 003 (ČSN EN ISO 15061; ČSN EN ISO 10304-1; ČSN EN ISO 10304-4)
5 Workplace and outdoor air, emissions Determination of anions by ion chromatography (conductivity detection)
fluorides chlorides nitrates phosphates sulphates
HF (hydrogen fluoride) (calculated), HCl (hydrogen chloride, hydrochloric acid) (calculated), HNO3 (nitric acid) (calculated), H3PO4 (phosphoric acid) (calculated), H2SO4 (sulphuric acid) (calculated), SO3 (sulphur trioxide) (calculated)
Regulated area: 1 Basic chemistry
SOP OV 003.01 (ČSN EN ISO 10304-1)
6 Surface, ground, waste and process water, drinking water Determination of biochemical oxygen demand after n days (BODn) – with oxygen electrode
Regulated area: 1 Basic chemistry
SOP OV 005 (ČSN EN ISO 5815-1; ČSN EN 1899-2)
7 Waste, solid samples Determination of total nitrogen by spectrophotometry (modified Kjeldahl method)
Regulated area: 1 Basic chemistry
SOP OV 006.06 (ČSN ISO 11261)
8 Water, extracts Determination of total nitrogen by spectrophotometry with MERCK set
Regulated area: 1 Basic chemistry
SOP OV 006.02 (návod firmy MERCK)
9 Water, extracts Determination of total nitrogen after oxidation to nitrogen oxides by chemiluminescence detection, inorganic and organic nitrogen by calculation from measured values
inorganic nitrogen (calculated), organic nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 006.07 (ČSN EN ISO 20236)
10 Water, extracts Determination of total phosphorus by spectrophotometry with MERCK set
Regulated area: 1 Basic chemistry
SOP OV 007.01 (návod firmy MERCK)
11 Waste, solid samples Determination of nitrate by ion chromatography and nitrate nitrogen by calculation from measured values
nitrate nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 003.02 (JPP ÚKZÚZ, Analýza půd III; ČSN EN ISO 10304-1)
12 Water, purified water, bottled water, extracts Determination of electrical conductivity
Regulated area: 1 Basic chemistry
SOP OV 011 (ČSN EN 27888)
13 Water, extracts Determination of univalent phenols by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 046 (ČSN ISO 6439)
14 Water, purified water, extracts Determination of phenols by continuous flow analysis
Regulated area: 1 Basic chemistry
SOP OV 083 (ČSN EN ISO 14402)
15 Water, bottled water, extracts, workplace air Determination of fluoride by potentiometry (ISE)
Regulated area: 1 Basic chemistry
SOP OV 012 (ČSN ISO 10359-1)
16 Water, bottled water, extracts Determination of aggressive carbon dioxide by Heyer marble test by titration and calculation of the forms of carbon dioxide (CO2 free, bound, total, hydrogencarbonates (HCO3-) and carbonates (CO32-)) from ANC and BNC values
aggressive carbon dioxide
forms of carbon dioxide (calculated)
Regulated area: 1 Basic chemistry
SOP OV 013 (ČSN 75 7373)
17 Drinking, surface, ground and bottled water Determination of humic substances by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 014 (ČSN 75 7536)
18 Water, extracts Determination of chemical oxygen demand with dichromate (CODCr) by spectrophotometry with MERCK set
Regulated area: 1 Basic chemistry
SOP OV 015.03 (ČSN ISO 15705; návod firmy MERCK)
19 Water, bottled water, extracts Determination of chemical oxygen demand with dichromate (CODCr) by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 015.01 (ČSN ISO 15705)
20 Drinking, ground, surface, bathing and hot water, bottled water, extracts Titrimetric determination of chemical oxygen demand using permanganate (CODMn)
Regulated area: 1 Basic chemistry
SOP OV 016 (ČSN EN ISO 8467)
21 Surface and bathing water Preliminary sensory analysis
appearance (algal bloom, waste pollution, natural pollution) transparency
Regulated area: 1 Basic chemistry
SOP OV 062.01 (ČSN 75 7340)
22 Surface water Determination of chlorophyll-a by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 019 (ČSN ISO 10260)
23 Drinking, ground, surface, waste and process water, bottled water, extracts Determination of chrome (VI) by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 049 (ČSN ISO 11083; ČSN EN ISO 18412; ČSN EN ISO 17075-1)
24 Drinking, bottled, surface, ground and bathing water Determination of iodide by titration
Regulated area: 1 Basic chemistry
SOP OV 020.02 (ČSN 58 0111, část B, článek 16)
25 Water, bottled water, extracts Determination of total cyanide by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 022.01 (ČSN 75 7415, postup A)
26 Water, purified water, bottled water, extracts Determination of total cyanide and free cyanide by continuous flow analysis
total cyanide free cyanide
Regulated area: 1 Basic chemistry
SOP OV 084 (ČSN EN ISO 14403-2)
27 Water, bottled water, extracts Determination of acid neutralizing capacity (ANC) by titration
Regulated area: 1 Basic chemistry
SOP OV 024 (ČSN EN ISO 9963-1)
28 Water, bottled water, extracts Determination of acid neutralizing capacity (ANC) by potentiometry
Regulated area: 1 Basic chemistry
SOP OV 024.01 (ČSN EN ISO 9963-1)
29 Drinking, surface, ground, waste and process water Determination of suspended solids at 105 °C and 550 °C (annealing residue), total solids at 105 °C and 550 °C (annealing residue) by gravimetry and loss on ignition of suspended solids and total solids by calculation from measured values
suspended solids total solids
loss on ignition of suspended solids and total solids (calculated)
Regulated area: 1 Basic chemistry
SOP OV 025.01 (ČSN EN 872; ČSN 75 7350)
30 Water, bottled water, extracts Determination of dissolved solids (RL, RAS) by gravimetric method and total mineralization by calculation from measured values
total mineralization (calculated)
Regulated area: 1 Basic chemistry
SOP OV 026.01 (ČSN 75 7346; ČSN 75 7347; ČSN 75 7358; ČSN EN 15216)
31 Drinking, hot, bottled, surface and ground water Preliminary sensory analysis – odour and flavour
Regulated area: 1 Basic chemistry
SOP OV 062 (ČSN 75 7340)
32 Water, purified water, extracts, bottled water Determination of pH by potentiometry
Regulated area: 1 Basic chemistry
SOP OV 033 (ČSN ISO 10523)
33 Waste, solid samples Determination of pH by potentiometry
Regulated area: 1 Basic chemistry
SOP OV 033.01 (ČSN EN ISO 10390)
34 Drinking, bottled, surface and ground water, extracts of materials Determination of the threshold odour number and threshold flavour number
Regulated area: 1 Basic chemistry
SOP OV 034 (ČSN EN 1622)
35 Waste, solid samples, materials Determination of dry matter by gravimetry and water content (moisture) by calculation from measured values
water content (moisture) (calculated)
Regulated area: 1 Basic chemistry
SOP OV 040.01 (ČSN EN 15934, metoda A)
36 Water, purified and bottled water, extracts Determination of anionic surfactants using methylene blue by continuous flow analysis
Regulated area: 1 Basic chemistry
SOP OV 085 (ČSN ISO 16265)
37 Drinking, hot, bottled, surface, ground and bathing water, purified water, extracts Determination of turbidity by nephelometry
Regulated area: 1 Basic chemistry
SOP OV 044.01 (ČSN EN ISO 7027-1)
38 Water, bottled water, extracts Determination of base neutralizing capacity (BNC) by titration
Regulated area: 1 Basic chemistry
SOP OV 045 (ČSN 75 7372)
39 Waste, solid samples Determination of loss on ignition (combustible matter) by gravimetry and annealing residue by calculation from measured values
annealing residue (calculated)
Regulated area: 1 Basic chemistry
SOP OV 040.02 (ČSN 46 5735; ČSN EN 15935)
40 Water, bottled water, extracts Determination of iron by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 051 (ČSN ISO 6332)
41 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of ammonium by photometry using automatic analyzer and ammonia nitrogen by calculation from measured values
ammonia nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 064 (návod firmy Thermo Scientific)
42 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of colour by photometry using automatic analyzer
Regulated area: 1 Basic chemistry
SOP OV 064.02 (návod firmy Thermo Scientific)
43 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of nitrate by photometry using automatic analyzer and nitrate nitrogen by calculation from measured values
nitrate nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 064.03 (návod firmy Thermo Scientific)
44 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of nitrite by photometry using automatic analyzer and nitrite nitrogen by calculation from measured values
nitrite nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 064.04 (návod firmy Thermo Scientific)
45 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of chlorides by photometry using automatic analyzer
Regulated area: 1 Basic chemistry
SOP OV 064.05 (návod firmy Thermo Scientific)
46 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of sulphate by photometry using automatic analyzer
Regulated area: 1 Basic chemistry
SOP OV 064.06 (návod firmy Thermo Scientific)
47 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of phosphate by photometry using automatic analyzer
Regulated area: 1 Basic chemistry
SOP OV 064.10 (návod firmy Thermo Scientific)
48 Water, purified water Determination of total and free chlorine by spectrophotometry by HACH set and bound chlorine by calculation from measured values
total chlorine free chlorine
bound chlorine (calculated)
Regulated area: 1 Basic chemistry
SOP OV 008.01 (návod firmy HACH)
49 Water Determination of pH by potentiometry
Regulated area: 1 Basic chemistry
SOP OV 033.02 (ČSN ISO 10523)
50 Drinking, ground, bathing and purified water, waste and process water Determination of chlorine dioxide by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 018.01 (návod firmy HACH/MERCK)
51 Bathing water, drinking water Determination of ozone by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 032.02 (návod firmy HACH/MERCK)
52 Water, purified water Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042 (ČSN 75 7342)
53 Foods Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042.01 (ČSN EN 13485)
54 Building materials (insulation material, roofing felt, roofing, plaster, fabrics, chipboard, pipes, building boards, loose and lump aggregate) Qualitative determination of asbestos fibres by SEM-EDS technique
Regulated area: 1 Basic chemistry
SOP OV 081 (VDI 3492, příloha D; VDI 3866, část 5)
55 Purified water Chemical tests for cleanness of water (qualitative)
chlorides sulphates nitrates oxidisable substances ammonium calcium and magnesium acid-reacting substances alkali-reacting substances
Regulated area: 1 Basic chemistry
SOP OV 055 (ČL, článek A, 11.4:0008)
56 Purified water Determination of electrical conductivity
Regulated area: 1 Basic chemistry
SOP OV 055.01 (ČL, článek A, 11.4:0008)
57 Purified water Determination of evaporation residue by gravimetry
Regulated area: 1 Basic chemistry
SOP OV 055.02 (ČL, článek A, 11.4:0008)
58 Urine Determination of creatinine by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 503 (Příloha č. 4/1985 k AHEM)
59 Urine Determination of hippuric acid by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 505.01 (Příloha č. 4/1985 k AHEM)
60 Materials, extracts of materials Determination of total migration by gravimetry
Regulated area: 1 Basic chemistry
SOP OV 608 (Vyhláška 38/2001 Sb.; Nařízení Komise EU č. 10/2011; ČSN EN 1186-3)
61 Materials, extracts Determination of primary aromatic amines by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 603 (ČSN 62 1156)
62 Materials, extracts of materials Determination of formaldehyde by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 609 (ČSN EN ISO 14184-1; ČSN EN ISO 4614, část B)
63 Foods, spirits, extracts of materials, articles of common use Sensory analysis
assessment of appearance and consistency olfactory assessment gustatory assessment
Regulated area: 2 Basic chemistry of food
SOP OV 124 (ČSN ISO 6658; ČSN 58 0120; AHEM 24/1986; AHEM 13/1982)
64 Foods Determination of sugars (reducing sugars, sugars expressed as saccharose (total sugar)) by titration
Regulated area: 2 Basic chemistry of food
SOP OV 123
65 Foods Determination of nitrogen by titration and protein by calculation from measured values
Regulated area: 2 Basic chemistry of food
SOP OV 104
66 Foods, spirits Determination of alcohol by pycnometry
Regulated area: 2 Basic chemistry of food
SOP OV 108
67 Foods Determination of sodium chloride by titration
Regulated area: 2 Basic chemistry of food
SOP OV 110
68 Foods Determination of acidity by titration
Regulated area: 2 Basic chemistry of food
SOP OV 114
69 Foods Determination of sulphur dioxide by titration
Regulated area: 2 Basic chemistry of food
SOP OV 125
70 Foods Determination of pH by potentiometry
Regulated area: 2 Basic chemistry of food
SOP OV 120
71 Foods Determination of ash content by gravimetry
Regulated area: 2 Basic chemistry of food
SOP OV 122
72 Foods Determination of dry matter by gravimetry, moisture (water content) by calculation from measured values, determination of energy value and saccharides by calculation from measured values
Regulated area: 2 Basic chemistry of food
SOP OV 118
73 Foods Determination of fat by gravimetry
Regulated area: 2 Basic chemistry of food
SOP OV 130
74 Foods Determination of moisture (water content) by distillation
Regulated area: 2 Basic chemistry of food
SOP OV 134.01 (ČSN ISO 939)
75 Foods Determination of fibre by gravimetry
Regulated area: 2 Basic chemistry of food
SOP OV 132 (Metoda AOAC 985.29 Total Dietary Fiber in Foods – Enzymatic-Gravimetric Method)
76 Water, purified water, bottled water, extracts, dialysates from DGT samplers Determination of elements by ICP-MS method
silver (Ag) aluminium (Al) arsenic (As) boron (B) barium (Ba) beryllium (Be) bismuth (Bi) calcium (Ca) cadmium (Cd) cobalt (Co) total chromium (Cr) copper (Cu) iron (Fe) iodine (I) potassium (K) lithium (Li) magnesium (Mg) manganese (Mn) molybdenum (Mo) sodium (Na) nickel (Ni) phosphorus (P) lead (Pb) antimony (Sb) selenium (Se) silicon (Si) tin (Sn) strontium (Sr) titanium (Ti) thallium (Tl) uranium (U) vanadium (V) tungsten (W) zinc (Zn) europium (Eu) gadolinium (Gd) lanthanum (La) terbium (Tb) yttrium (Y)
silicates (calculated), SiO2 (calculated), P2O5 (written “P205”) (calculated), hardness (Ca+Mg, CaCO3) (calculated)
Regulated area: 3 Metals
SOP OV 201 (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)
77 Waste, solid samples, materials Determination of elements by ICP-MS method
arsenic (As) barium (Ba) beryllium (Be) cadmium (Cd) cobalt (Co) copper (Cu) total chromium (Cr) iron (Fe) manganese (Mn) molybdenum (Mo) nickel (Ni) lead (Pb) antimony (Sb) tin (Sn) strontium (Sr) thallium (Tl) zinc (Zn)
Regulated area: 3 Metals
SOP OV 201.05 (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)
78 Indoor, outdoor and workplace air, emissions Determination of elements by ICP-MS method
silver (Ag) aluminium (Al) arsenic (As) boron (B) barium (Ba) beryllium (Be) calcium (Ca) cadmium (Cd) cobalt (Co) copper (Cu) total chromium (Cr) iron (Fe) potassium (K) magnesium (Mg) manganese (Mn) molybdenum (Mo) sodium (Na) nickel (Ni) lead (Pb) antimony (Sb) selenium (Se) tin (Sn) strontium (Sr) titanium (Ti) thallium (Tl) vanadium (V) tungsten (W) zinc (Zn)
CaO (calculated), MgO (calculated), KOH (calculated), NaOH (calculated)
Regulated area: 3 Metals
SOP OV 201.04 (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; ČSN EN 14902)
79 Biological material (blood, urine) Determination of elements by ICP-MS method
aluminium (Al) arsenic (As) cadmium (Cd) cobalt (Co) total chromium (Cr) copper (Cu) lithium (Li) nickel (Ni) lead (Pb) selenium (Se) zinc (Zn) iodine (I)
Regulated area: 3 Metals
SOP OV 201.03 (ČSN EN ISO 17294-1; Aplikační listy PerkinElmer Simultaneous Direct Determination of 25 Metals in Urine with ICP-MS using Collision/Reaction Techmology; Simultaneous Determination of 28 elements in serum by ICP-MS using collision and reaction gases)
80 Foods, feedingstuffs Determination of elements by ICP-MS method
aluminium (Al) arsenic (As) barium (Ba) calcium (Ca) cadmium (Cd) cobalt (Co) copper (Cu) total chromium (Cr) iron (Fe) iodine (I) potassium (K) magnesium (Mg) manganese (Mn) molybdenum (Mo) sodium (Na) nickel (Ni) phosphorus (P) lead (Pb) antimony (Sb) selenium (Se) tin (Sn) strontium (Sr) vanadium (V) zinc (Zn)
P2O5 (written “P205”) (calculated), NaCl (calculated)
Regulated area: 3 Metals
SOP OV 201.10 (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)
81 Water, bottled water, purified water, extracts, dialysates from DGT samplers Determination of elements by ICP-OES method
silver (Ag) aluminium (Al) arsenic (As) boron (B) barium (Ba) beryllium (Be) bismuth (Bi) calcium (Ca) cadmium (Cd) cobalt (Co) copper (Cu) total chromium (Cr) iron (Fe) potassium (K) lithium (Li) magnesium (Mg) manganese (Mn) molybdenum (Mo) sodium (Na) nickel (Ni) phosphorus (P) lead (Pb) antimony (Sb) selenium (Se) silicon (Si) tin (Sn) strontium (Sr) titanium (Ti) thallium (Tl) vanadium (V) zinc (Zn)
K2O (calculated), P2O5 (calculated), SiO2 (calculated), silicates (calculated), hardness (Ca+Mg, CaCO3) (calculated)
Regulated area: 3 Metals
SOP OV 201.01 (ČSN EN ISO 11885)
82 Waste, solid samples, materials Determination of elements by ICP-OES method
silver (Ag) aluminium (Al) arsenic (As) boron (B) barium (Ba) beryllium (Be) calcium (Ca) cadmium (Cd) cobalt (Co) copper (Cu) total chromium (Cr) iron (Fe) potassium (K) lithium (Li) magnesium (Mg) manganese (Mn) molybdenum (Mo) sodium (Na) nickel (Ni) phosphorus (P) lead (Pb) antimony (Sb) selenium (Se) tin (Sn) strontium (Sr) thallium (Tl) vanadium (V) zinc (Zn)
K2O (calculated), P2O5 (calculated), CaO (calculated), MgO (calculated)
Regulated area: 3 Metals
SOP OV 201.06 (ČSN EN ISO 11885)
83 Foods, feedingstuffs Determination of elements by ICP-OES method
aluminium (Al) barium (Ba) calcium (Ca) copper (Cu) iron (Fe) potassium (K) magnesium (Mg) manganese (Mn) sodium (Na) phosphorus (P) tin (Sn) strontium (Sr) zinc (Zn)
P2O5 (calculated), NaCl (calculated)
Regulated area: 3 Metals
SOP OV 201.11 (ČSN EN ISO 11885)
84 Waste, solid samples, materials Determination of elements by X-ray spectrometry method
aluminium (Al) arsenic (As) barium (Ba) calcium (Ca) cadmium (Cd) total chromium (Cr) copper (Cu) iron (Fe) mercury (Hg) potassium (K) magnesium (Mg) manganese (Mn) nickel (Ni) lead (Pb) antimony (Sb) selenium (Se) silicon (Si) tin (Sn) titanium (Ti) thallium (Tl) uranium (U) vanadium (V) zinc (Zn)
MgO (calculated), Al2O3 (calculated), SiO2 (calculated), K2O (calculated), CaO (calculated), TiO2 (calculated), MnO (calculated), Fe2O3 (calculated), CaCO3 (calculated), MgCO3 (calculated)
Regulated area: 3 Metals
SOP OV 202 (manuál fy SPECTRO)
85 Water, bottled and purified water, extracts, waste, solid samples, indoor, outdoor and workplace air, mineral oils, dialysates from DGT samplers, emissions, feedingstuffs, foods, materials Determination of mercury by single purpose atomic absorption spectrometer
Regulated area: 3 Metals
SOP OV 200.03 (ČSN 75 7440)
86 Water, extracts Determination of AOX (adsorbable organically bound halogens), EOX (extractable organically bound halogens), TX (total halogen compounds) and halogenides (sum of chlorides, bromides and iodides) by coulometry
AOX EOX TX halogenides (sum of chlorides, bromides and iodides)
Regulated area: 4 Organic chemistry
SOP OV 305.01 (ČSN EN ISO 9562)
87 Waste, solid samples Determination of AOX (adsorbable organically bound halogens), EOX (extractable organically bound halogens), TX (total halogen compounds) and halogenides (sum of chlorides, bromides and iodides) by coulometry
AOX EOX TX halogenides (sum of chlorides, bromides and iodides)
Regulated area: 4 Organic chemistry
SOP OV 305.04 (DIN 38414-17; ČSN EN 16166)
88 Water, bottled water, purified water, extracts Determination of total organic carbon (TOC) and dissolved organic carbon (DOC) by infrared spectrometry method
total organic carbon (TOC) dissolved organic carbon (DOC)
Regulated area: 4 Organic chemistry
SOP OV 307 (ČSN EN 1484)
89 Waste, solid samples Determination of total organic carbon (TOC) by infrared spectrometry method
Regulated area: 4 Organic chemistry
SOP OV 307.02 (ČSN EN 13137:2002)
90 Indoor and outdoor air Determination of odour substances by dynamic olfactometry
Regulated area: 5 Air
SOP OV 401 (ČSN EN 13725)
91 Indoor, outdoor and workplace air Determination of dust and solid pollutants by gravimetry
Regulated area: 5 Air
SOP OV 403
92 Outdoor air Determination of mass of dustfall by gravimetry
Regulated area: 5 Air
SOP OV 404
93 Indoor, outdoor and workplace air Determination of numerical concentration of mineral fibres by SEM method with EDX analyzer
Regulated area: 5 Air
SOP OV 405.01 (VDI 3492)
94 Workplace air Preliminary determination of gases and vapours by detection tubes
ammonia (NH3) chlorine (Cl2) nitrogen dioxide (NO2) nitric oxide (NO) hydrogen sulphide (H2S) sulphur dioxide (SO2) hydrogen cyanide (HCN) carbon dioxide (CO2) ozone (O3) carbon monoxide (CO) carbon disulphide (CS2) phenol nitrous gases (NOx) hydrogen (H2) hydrogen peroxide (H2O2)
Regulated area: 5 Air
SOP OV 424 (manuály firmy GASTEC a Dräger)
95 Indoor, outdoor and workplace air Measurement of the concentration of dust by automatic analyzers – optical method
Regulated area: 5 Air
SOP OV 436 (ČSN EN 16450)
96 Indoor and outdoor air Measurement of the concentration of dust by automatic analyzers – gravimetric (frequency) method
Regulated area: 5 Air
SOP OV 436.01 (ČSN EN 16450)
97 Indoor, outdoor and workplace air, compressed gases Measurement of concentration of gaseous pollutants – electrochemical method
sulphur dioxide (SO2) hydrogen sulphide (H2S) carbon monoxide (CO) nitric oxide (NO) nitrogen dioxide (NO2) oxygen (O2) ammonia (NH3)
Regulated area: 5 Air
SOP OV 438
98 Indoor and outdoor air Determination of sulphur dioxide (SO2) and hydrogen sulphide (H2S) by UV fluorescence
sulphur dioxide (SO2) hydrogen sulphide (H2S)
Regulated area: 5 Air
SOP OV 438.03 (ČSN EN 14212)
99 Indoor, outdoor and workplace air Determination of ozone (O3) by UV absorption
Regulated area: 5 Air
SOP OV 438.04 (ČSN EN 14625)
100 Indoor and outdoor air Determination of nitrogen oxides by chemiluminescence
Regulated area: 5 Air
SOP OV 438.05 (ČSN EN 14211)
101 Indoor, outdoor and workplace air, compressed gases Determination of carbon monoxide (CO) and carbon dioxide (CO2) with an infrared spectrometry analyzer
carbon monoxide (CO) carbon dioxide (CO2)
Regulated area: 5 Air
SOP OV 438.07
102 Indoor air, cleanrooms and clean zones Enumeration of particles – optical method
size fractions from 0.30 to 25.0 µm
Regulated area: 5 Air
SOP OV 436.03 (ČSN EN ISO 14644-1; VYR-32 doplněk 1)
103 Indoor and workplace air Determination of vapours and gases by calculation from specified values
Regulated area: 5 Air
SOP OV 486 (Nařízení vlády č. 361/2007 Sb.; Vyhláška 43/2025 Sb.)
104 Working and non-working environment Measurement and calculation of noise
Regulated area: 6 Physical factors
Měření SOP OV 456, část 1; Výpočet SOP OV 456, část 2
105 Indoor spaces Measurement of reverberation time
Regulated area: 6 Physical factors
SOP OV 464 (ČSN EN ISO 3382-2; ČSN EN ISO 3382-1)
106 Building structures Measurement of airborne sound insulation
Regulated area: 6 Physical factors
SOP OV 468
107 Building structures Measurement of impact sound insulation
Regulated area: 6 Physical factors
SOP OV 468.02
108 Working and non-working environment Measurement of vibration
Regulated area: 6 Physical factors
SOP OV 471
109 Working and non-working environment, roads Measurement of electrical lighting
Regulated area: 6 Physical factors
SOP OV 469
110 Working and non-working environment Measurement of daylight
Regulated area: 6 Physical factors
SOP OV 470
111 Working and non-working environment, cleanrooms and clean zones Measurement of microclimatic conditions
globe temperature air temperature relative air humidity air velocity
operative temperature (calculated)
Regulated area: 6 Physical factors
SOP OV 474
112 Working and non-working environment Measurement of electromagnetic field
Regulated area: 6 Physical factors
SOP OV 452
113 Working and non-working environment Measurement of ultraviolet radiation parameters
Regulated area: 6 Physical factors
SOP OV 455
114 Ground, surface and waste water, extracts Determination of acute toxicity to Daphnia magna
Regulated area: 7 Ecotoxicology
SOP OV 801 (ČSN EN ISO 6341)
115 Ground, surface and waste water, extracts Determination of acute toxicity to green algae Desmodesmus subspicatus
Regulated area: 7 Ecotoxicology
SOP OV 802 (ČSN EN ISO 8692)
116 Ground, surface and waste water, extracts Determination of the inhibitory effect of tested samples on the light emission of Aliivibrio fischeri
Regulated area: 7 Ecotoxicology
SOP OV 805 (ČSN EN ISO 11348-2)
117 Waste, solid samples Determination of root growth inhibition in lettuce Lactuca sativa
Regulated area: 7 Ecotoxicology
SOP OV 811 (ČSN EN ISO 11269-1)
118 Water, bottled water Detection and enumeration of coliform bacteria and Escherichia coli by membrane filtration method
Regulated area: 9 Microbiology
SOP OV 900 (ČSN EN ISO 9308-1)
119 Water, bottled water Detection and enumeration of thermotolerant coliform bacteria – Membrane filtration method
Regulated area: 9 Microbiology
SOP OV 903 (ČSN 75 7835)
120 Water, bottled water Detection and enumeration of intestinal enterococci – Membrane filtration method
Regulated area: 9 Microbiology
SOP OV 906 (ČSN EN ISO 7899-2)
121 Water, bottled water Enumeration of culturable microorganisms by inoculation in or on a nutrient agar culture medium at: 36 °C and 22 °C
Regulated area: 9 Microbiology
SOP OV 908 (ČSN EN ISO 6222)
122 Water, bottled water Detection and enumeration of Staphylococcus aureus – Membrane filtration method
Regulated area: 9 Microbiology
SOP OV 911 (ČSN EN ISO 6888-1)
123 Water, bottled water Detection and enumeration of Legionella spp. by culture method
Regulated area: 9 Microbiology
SOP OV 913 (ČSN EN ISO 11731)
124 Water, bottled water Enumeration of sulfite-reducing clostridia – Membrane filtration method
Regulated area: 9 Microbiology
SOP OV 914 (ČSN EN 26461-2)
125 Water, bottled water Detection of Salmonella by culture method
Regulated area: 9 Microbiology
SOP OV 921 (ČSN ISO 19250)
126 Water, bottled water, purified water Detection and enumeration of Pseudomonas aeruginosa – Membrane filtration method
Regulated area: 9 Microbiology
SOP OV 909 (ČSN EN ISO 16266)
127 Drinking, bottled, surface, bathing and ground water Determination of microscopic image
Regulated area: 9 Microbiology
SOP OV 916 (ČSN 75 7712; ČSN 75 7713; ČSN 75 7717)
128 Water Enumeration of Clostridium perfringens – membrane filtration method
Regulated area: 9 Microbiology
SOP OV 914.03 (ČSN EN ISO 14189)
129 Purified water, non-sterile products Microbiological examination of non-sterile products – by culture
Regulated area: 9 Microbiology
SOP OV 930
130 Purified water Detection of bacterial endotoxins by LAL test (gel-clot method)
Regulated area: 9 Microbiology
SOP OV 931 (ČL, část 2.6.14)
131 Water Enumeration of coliform bacteria and Escherichia coli by the Colilert Quanti-Tray method
Regulated area: 9 Microbiology
SOP OV 936 (ČSN EN ISO 9308-2)
132 Foods Enumeration of coliform bacteria by culture
Regulated area: 9 Microbiology
SOP OV 901 (ČSN ISO 4832)
133 Foods Enumeration of Escherichia coli by culture
Regulated area: 9 Microbiology
SOP OV 902 (ČSN ISO 16649-2)
134 Foods Enumeration of coagulase-positive staphylococci by culture
Regulated area: 9 Microbiology
SOP OV 912 (ČSN EN ISO 6888-1)
135 Foods Enumeration of Clostridium perfringens by culture
Regulated area: 9 Microbiology
SOP OV 915 (ČSN EN ISO 15213-2)
136 Foods Enumeration of total microorganisms by culture
Regulated area: 9 Microbiology
SOP OV 917 (ČSN EN ISO 4833-1)
137 Foods Enumeration of yeasts and moulds by culture
Regulated area: 9 Microbiology
SOP OV 918 (ČSN ISO 21527-1; ČSN ISO 21527-2)
138 Foods Enumeration of potentially toxinogenic moulds by culture
Regulated area: 9 Microbiology
SOP OV 918.01 (AHEM 1/2003)
139 Foods Detection and enumeration of Enterobacteriaceae by culture
Regulated area: 9 Microbiology
SOP OV 919 (ČSN EN ISO 21528-1; ČSN EN ISO 21528-2)
140 Foods Detection of Salmonella by culture
Regulated area: 9 Microbiology
SOP OV 920 (ČSN EN ISO 6579-1)
141 Foods Detection and enumeration of Listeria monocytogenes by culture
Regulated area: 9 Microbiology
SOP OV 923 (ČSN EN ISO 11290-1; ČSN EN ISO 11290-2)
142 Foods Detection and enumeration of Campylobacter by culture
Regulated area: 9 Microbiology
SOP OV 924 (ČSN EN ISO 10272-1; ČSN EN ISO 10272-2)
143 Foods Enumeration of presumptive Bacillus cereus by culture
Regulated area: 9 Microbiology
SOP OV 925 (ČSN EN ISO 7932)
144 Waste, solid samples Enumeration of thermotolerant coliform bacteria and Escherichia coli by culture
Regulated area: 9 Microbiology
SOP OV 904 (AHEM 1/2008)
145 Waste, solid samples Enumeration of enterococci by culture
Regulated area: 9 Microbiology
SOP OV 907 (AHEM 1/2008)
146 Waste, solid samples Detection of Salmonella by culture
Regulated area: 9 Microbiology
SOP OV 922 (AHEM 1/2008)
147 Surfaces, surfaces of objects, packaging, articles of common use Determination of microbial contamination by culture
Regulated area: 9 Microbiology
SOP OV 927 (ČSN 56 0100:1970, kapitola VIII, články 144-148)
148 Indoor, outdoor and workplace air, compressed gases Determination of microbial contamination by culture
Regulated area: 9 Microbiology
SOP OV 928 (AHEM 1/2002; AHEM 4/2021)
149 Sterile products Sterility test by culture
Regulated area: 9 Microbiology
SOP OV 929 (ČL, část 2.6.1)
150 Articles of common use Enumeration and detection of aerobic mesophilic bacteria by culture
Regulated area: 9 Microbiology
SOP OV 983 (ČSN EN ISO 21149)
151 Articles of common use Detection of Pseudomonas aeruginosa by culture
Regulated area: 9 Microbiology
SOP OV 984 (ČSN EN ISO 22717)
152 Articles of common use Detection of Staphylococcus aureus by culture
Regulated area: 9 Microbiology
SOP OV 985 (ČSN EN ISO 22718)
153 Articles of common use Detection of Candida albicans by culture
Regulated area: 9 Microbiology
SOP OV 986 (ČSN EN ISO 18416)
154 Articles of common use Detection of Escherichia coli by culture
Regulated area: 9 Microbiology
SOP OV 988 (ČSN EN ISO 21150)
155 Biological indicators Examination of biological indicators by culture
Regulated area: 9 Microbiology
SOP OV 933 (AHEM 1/2014)
156 Sterilizers Verification of the efficiency of sterilizers using chemical tests
Regulated area: 9 Microbiology
SOP OV 933.01
157 Washer-disinfectors Verification of the efficiency of washer-disinfectors using chemical tests
Regulated area: 9 Microbiology
SOP OV 933.02
158 Drinking, surface and ground water Enumeration of somatic coliphages
Regulated area: 9 Microbiology
SOP OV 990 (ČSN EN ISO 10705-2)
159 Drinking and hot water Sampling of drinking water
Regulated area: Sampling
SOP VZ OV 001 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
160 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP VZ OV 002 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; ČSN 75 7717; Vyhláška č. 238/2011 Sb.)
161 Ground water Sampling of ground water – manual sampling and sampling by pumping
Regulated area: Sampling
SOP VZ OV 003 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)
162 Surface water Sampling from reservoirs, rivers and streams
Regulated area: Sampling
SOP VZ OV 005 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
163 Waste water Sampling of waste water – manual sampling and sampling with an automatic sampler
Regulated area: Sampling
SOP VZ OV 006 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
164 Purified water Sampling of purified water
Regulated area: Sampling
SOP VZ OV 008 (Vyhláška č. 84/2008 Sb.)
165 Outdoor and indoor air, compressed gases Sampling of outdoor and indoor air and compressed gases on a solid sorbent (filter, filter and PUF, sorption tube)
Regulated area: Sampling
SOP VZ OV 109 (Zákon o ochraně ovzduší 201/2012 Sb.; ČSN EN 12341; ČSN EN ISO 16000-7; Vyhláška č. 330/2012 Sb.)
166 Outdoor and indoor air Sampling of outdoor and indoor air into liquid (sorption solution, sedimentation vessel)
Regulated area: Sampling
SOP VZ OV 109.01 (Zákon o ochraně ovzduší 201/2012 Sb.)
167 Outdoor and indoor air Sampling of outdoor and indoor air into bags
Regulated area: Sampling
SOP VZ OV 109.02 (Zákon o ochraně ovzduší 201/2012 Sb.)
168 Outdoor and indoor air Sampling of outdoor and indoor air onto culture media
Regulated area: Sampling
SOP VZ OV 109.03 (AHEM 1/2002; AHEM 4/2021)
169 Workplace air Sampling of workplace air on a solid sorbent (filter, filter and PUF, filter and sorbent, sorption tube)
Regulated area: Sampling
SOP VZ OV 110 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007Sb.)
170 Workplace air Sampling of workplace air into liquid (fritted absorbers with absorption solution)
Regulated area: Sampling
SOP VZ OV 110.01 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007 Sb.)
171 Workplace air Sampling of workplace air into canisters
Regulated area: Sampling
SOP VZ OV 110.02 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007 Sb.)
172 Compressed gases Sampling of compressed gases onto culture media
Regulated area: Sampling
SOP VZ OV 217 (Manuál MAS-100 CG Ex fy MBV, A.G.)
173 Waste (solid and liquid waste, biodegradable waste) Sampling of waste
Regulated area: Sampling
SOP VZ OV 201 (ČSN EN 14899; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5)
174 Sand Sampling of sand from sandpits and outdoor playgrounds
Regulated area: Sampling
SOP VZ OV 204 (Pokyn hlavního hygienika ČR k zajištění jednotného postupu při kontrolách pískovišť venkovních hracích ploch, č.j. 3209/2014 ze dne 12.3.2014)
175 Solid samples (soils, sands, sediments, sludges) Sampling of solid samples
Regulated area: Sampling
SOP VZ OV 218 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN 01 5110; ČSN 01 5111; ČSN 01 5112)
176 Foods Sampling of foods for microbiological testing
Regulated area: Sampling
SOP VZ OV 200 (ČSN P CEN ISO/TS 17728)
177 Surfaces, skin Sampling from surfaces of objects for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 206 (ČSN EN ISO 18593)
178 Sterilizers Sampling with biological and non-biological systems for verification of sterilizer efficiency
Regulated area: Sampling
SOP VZ OV 213 (AHEM 1/2014)
Olomouc
179 Drinking, ground, surface and bathing water, extracts Determination of absorbance
Regulated area: 1 Basic chemistry
SOP OV 001 (ČSN 75 7360)
180 Water, bottled water, extracts Determination of ammonium by spectrophotometry and ammonia nitrogen by calculation from measured values
ammonia nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 002 (ČSN ISO 7150-1)
181 Drinking, ground, surface, bathing, waste and process water Determination of ammonium by titration and ammonia nitrogen by calculation from measured values
ammonia nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 002.03 (ČSN ISO 5664)
182 Water, purified water, bottled water, extracts Determination of anions by ion chromatography (conductivity detection)
fluorides chlorides nitrites nitrates phosphates sulphates bromides bromates chlorites chlorates
nitrite nitrogen (calculated), nitrate nitrogen (calculated), phosphorus pentoxide (P2O5) (calculated), sum of chlorates and chlorites (calculated)
Regulated area: 1 Basic chemistry
SOP OV 003 (ČSN EN ISO 15061; ČSN EN ISO 10304-1; ČSN EN ISO 10304-4)
183 Surface, ground, waste and process water, drinking water Determination of biochemical oxygen demand after n days (BODn) – with oxygen electrode
Regulated area: 1 Basic chemistry
SOP OV 005 (ČSN EN ISO 5815-1; ČSN EN 1899-2)
184 Water, purified water, bottled water, extracts Determination of total phosphorus, phosphate by spectrophotometry and phosphorus pentaoxide by calculation from measured values
total phosphorus phosphate
phosphorus pentaoxide (calculated)
Regulated area: 1 Basic chemistry
SOP OV 007 (ČSN EN ISO 6878)
185 Water, purified water, bottled water, extracts Determination of electrical conductivity
Regulated area: 1 Basic chemistry
SOP OV 011 (ČSN EN 27888)
186 Water, bottled water, extracts Determination of aggressive carbon dioxide by Heyer marble test by titration and calculation of the forms of carbon dioxide (CO2 free, bound, total, hydrogencarbonates (HCO3-) and carbonates (CO32-)) from ANC and BNC values
forms of carbon dioxide (calculated)
Regulated area: 1 Basic chemistry
SOP OV 013 (ČSN 75 7373)
187 Drinking, surface, ground and bottled water Determination of humic substances by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 014 (ČSN 75 7536)
188 Water Determination of chemical oxygen demand using dichromate (CODCr) by spectrophotometry with HACH set
Regulated area: 1 Basic chemistry
SOP OV 015.02 (ČSN ISO 15705; návod firmy HACH)
189 Drinking, ground, surface, bathing and hot water, bottled water, extracts Titrimetric determination of chemical oxygen demand using permanganate (CODMn)
Regulated area: 1 Basic chemistry
SOP OV 016 (ČSN EN ISO 8467)
190 Surface and bathing water Preliminary sensory analysis
appearance (algal bloom, waste pollution, natural pollution) transparency
Regulated area: 1 Basic chemistry
SOP OV 062.01 (ČSN 75 7340)
191 Surface water Determination of chlorophyll-a by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 019 (ČSN ISO 10260)
192 Drinking, ground, surface, waste and process water, bottled water, extracts Determination of chrome (VI) by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 049 (ČSN ISO 11083; ČSN EN ISO 18412; ČSN EN ISO 17075-1)
193 Water, bottled water, extracts Determination of acid neutralizing capacity (ANC) by titration
Regulated area: 1 Basic chemistry
SOP OV 024 (ČSN EN ISO 9963-1)
194 Drinking, surface, ground, waste and process water Determination of suspended solids at 105 °C and 550 °C (annealing residue), total solids at 105 °C and 550 °C (annealing residue) by gravimetry and loss on ignition of suspended solids and total solids by calculation from measured values
suspended solids total solids
loss on ignition of suspended solids and total solids (calculated)
Regulated area: 1 Basic chemistry
SOP OV 025.01 (ČSN EN 872; ČSN 75 7350)
195 Water, bottled water, extracts Determination of dissolved solids (RL, RAS) by gravimetric method and total mineralization by calculation from measured values
total mineralization (calculated)
Regulated area: 1 Basic chemistry
SOP OV 026.01 (ČSN 75 7346; ČSN 75 7347; ČSN 75 7358; ČSN EN 15216)
196 Drinking, hot, bottled, surface and ground water Preliminary sensory analysis – odour and flavour
Regulated area: 1 Basic chemistry
SOP OV 062 (ČSN 75 7340)
197 Water, purified water, extracts, bottled water Determination of pH by potentiometry
Regulated area: 1 Basic chemistry
SOP OV 033 (ČSN ISO 10523)
198 Waste, solid samples, materials Determination of dry matter by gravimetry and water content (moisture) by calculation from measured values
water content (moisture) (calculated)
Regulated area: 1 Basic chemistry
SOP OV 040.01 (ČSN EN 15934, metoda A)
199 Drinking, hot, bottled, surface, ground and bathing water, purified water, extracts Determination of turbidity by nephelometry
Regulated area: 1 Basic chemistry
SOP OV 044.01 (ČSN EN ISO 7027-1)
200 Water, bottled water, extracts Determination of base neutralizing capacity (BNC) by titration
Regulated area: 1 Basic chemistry
SOP OV 045 (ČSN 75 7372)
201 Waste, solid samples Determination of loss on ignition (combustible matter) by gravimetry and annealing residue by calculation from measured values
annealing residue (calculated)
Regulated area: 1 Basic chemistry
SOP OV 040.02 (ČSN 46 5735; ČSN EN 15935)
202 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of ammonium by photometry using automatic analyzer and ammonia nitrogen by calculation from measured values
ammonia nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 064 (návod firmy Thermo Scientific)
203 Drinking, hot, bottled, bathing, surface and ground water, purified water Determination of alkalinity (ANC) by photometry using automatic analyzer
Regulated area: 1 Basic chemistry
SOP OV 064.01 (návod firmy Thermo Scientific)
204 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of colour by photometry using automatic analyzer
Regulated area: 1 Basic chemistry
SOP OV 064.02 (návod firmy Thermo Scientific)
205 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of nitrate by photometry using automatic analyzer and nitrate nitrogen by calculation from measured values
nitrate nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 064.03 (návod firmy Thermo Scientific)
206 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of nitrite by photometry using automatic analyzer and nitrite nitrogen by calculation from measured values
nitrite nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 064.04 (návod firmy Thermo Scientific)
207 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of chlorides by photometry using automatic analyzer
Regulated area: 1 Basic chemistry
SOP OV 064.05 (návod firmy Thermo Scientific)
208 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of sulphate by photometry using automatic analyzer
Regulated area: 1 Basic chemistry
SOP OV 064.06 (návod firmy Thermo Scientific)
209 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of phosphate by photometry using automatic analyzer
Regulated area: 1 Basic chemistry
SOP OV 064.10 (návod firmy Thermo Scientific)
210 Drinking, hot, bottled, bathing, surface and ground water, purified water Determination of pH by potentiometry using automatic analyzer
Regulated area: 1 Basic chemistry
SOP OV 064.12 (návod firmy Thermo Scientific)
211 Drinking, hot, bottled, bathing, surface and ground water, purified water Determination of electric conductivity using automatic analyzer
Regulated area: 1 Basic chemistry
SOP OV 064.13 (návod firmy Thermo Scientific)
212 Water, purified water Determination of total and free chlorine by spectrophotometry by HACH set and bound chlorine by calculation from measured values
total chlorine free chlorine
bound chlorine (calculated)
Regulated area: 1 Basic chemistry
SOP OV 008.01 (návod firmy HACH)
213 Drinking, ground, bathing and purified water, waste and process water Determination of chlorine dioxide by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 018.01 (návod firmy HACH/MERCK)
214 Bathing water, drinking water Determination of ozone by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 032.02 (návod firmy HACH/MERCK)
215 Water, purified water Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042 (ČSN 75 7342)
216 Foods Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042.01 (ČSN EN 13485)
217 Water, purified water, bottled water, extracts, dialysates from DGT samplers Determination of elements by ICP-MS method
silver (Ag) aluminium (Al) arsenic (As) boron (B) barium (Ba) beryllium (Be) calcium (Ca) cadmium (Cd) cobalt (Co) total chromium (Cr) copper (Cu) iron (Fe) potassium (K) lithium (Li) magnesium (Mg) manganese (Mn) molybdenum (Mo) sodium (Na) nickel (Ni) phosphorus (P) lead (Pb) antimony (Sb) selenium (Se) silicon (Si) tin (Sn) strontium (Sr) titanium (Ti) thallium (Tl) uranium (U) vanadium (V) tungsten (W) zinc (Zn)
silicates (calculated), SiO2 (calculated), P2O5 (written “P205”) (calculated), hardness (Ca+Mg, CaCO3) (calculated)
Regulated area: 3 Metals
SOP OV 201 (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)
218 Water, bottled and purified water, extracts, waste, solid samples, indoor, outdoor and workplace air, mineral oils, dialysates from DGT samplers, emissions, feedingstuffs, foods, materials Determination of mercury by single purpose atomic absorption spectrometer
Regulated area: 3 Metals
SOP OV 200.03 (ČSN 75 7440)
219 Workplace air Determination of diisocyanates by liquid chromatography (LC/FLD)
toluene-2,6-diisocyanate toluene-2,4-diisocyanate 1,6-hexamethylene diisocyanate 4,4′-methylenediphenyl diisocyanate
Regulated area: 4 Organic chemistry
SOP OV 316 (OSHA Metod No. 42, No. 47)
220 Materials, extracts Determination of phthalates by gas chromatography (GC/MS) and the sum of phthalates by calculation from measured values
dimethyl phthalate diethyl phthalate di-n-butyl phthalate benzyl butyl phthalate bis(2-ethylhexyl) phthalate (DEHP) di-n-octyl phthalate diisodecyl phthalate diisononyl phthalate n-octyl-n-decyl phthalate di-n-decyl phthalate diisobutyl phthalate
sum of phthalates (calculated)
Regulated area: 4 Organic chemistry
SOP OV 313 (ČSN EN ISO 18856)
221 Foods Determination of fatty acids by gas chromatography (GC/MS) and the sum of saturated, monounsaturated, polyunsaturated and transunsaturated fatty acids by the calculation from the measured values
butyric acid (C4:0) caproic acid (C6:0) caprylic acid (C8:0) capric acid (C10:0) undecanoic acid (C11:0) lauric acid (C12:0) tridecanoic acid (C13:0) myristic acid (C14:0) myristoleic acid (C14:1) pentadecanoic acid (C15:0) cis-10-pentadecenoic acid (C15:1) palmitic acid (C16:0) palmitoleic acid (C16:1) heptadecanoic acid (C17:0) cis-10-heptadecenoic acid (C17:1) stearic acid (C18:0) elaidic acid (C18:1n9t) oleic acid (C18:1n9c) linolelaidic acid (C18:2n6t) linoleic acid (C18:2n6c) arachidic acid (C20:0) γ-linolenic acid (C18:3n6) cis-11-eicosenoic (gondoic) acid (C20:1) α-linolenic acid (C18:3n3) heneicosanoic acid (C21:0) cis-11,14-eicosadienoic acid (C20:2) behenic acid (C22:0) cis-8,11,14-eicosatrienoic acid (C20:3n6) erucic acid (C22:1n9) cis-11,14,17-eicosatrienoic acid (C20:3n3) arachidonic acid (C20:4n6) tricosanoic acid (C23:0) cis-13,16-docosadienoic acid (C22:2) lignoceric acid (C24:0) eicosapentaenoic acid EPA (C20:5n3) nervonic acid (C24:1) docosahexaenoic acid DHA (C22:6n3)
sums of saturated, monounsaturated, polyunsaturated and trans fatty acids (calculated)
Regulated area: 4 Organic chemistry
SOP OV 336 (ČSN EN ISO 12966-1; ČSN EN ISO 12966-2)
222 Water, bottled water, extracts Determination of NEL (non-polar extractives) and EL (extractives) by infrared spectrometry
NEL (non-polar extractives) EL (extractives)
Regulated area: 4 Organic chemistry
SOP OV 309.01 (ČSN 75 7505:1998; ČSN 75 7506)
223 Water, bottled water, extracts Determination of polyaromatic hydrocarbons (PAH) by liquid chromatography (LC/FLD/DAD) and the sum of PAH by calculation from measured values
benzo(a)pyrene benzo(b)fluoranthene benzo(k)fluoranthene benzo(ghi)perylene indeno(1,2,3-cd)pyrene
sum of PAH (calculated)
Regulated area: 4 Organic chemistry
SOP OV 331 (ČSN EN ISO 17993)
224 Drinking, bottled, ground, surface and waste water Determination of polyaromatic hydrocarbons (PAH) by gas chromatography (GC/MS) and the sum of PAH by calculation from measured values
naphthalene acenaphthylene fluorene phenanthrene anthracene fluoranthene pyrene chrysene benzo(a)anthracene benzo(k)fluoranthene benzo(b)fluoranthene benzo(a)pyrene indeno(1,2,3-cd)pyrene dibenzo(ah)anthracene benzo(ghi)perylene
sum of PAH (calculated)
Regulated area: 4 Organic chemistry
SOP OV 331.01 (ČSN 75 7554:1998)
225 Water, bottled water, extracts Determination of polychlorinated biphenyls (PCB) by gas chromatography (GC/ECD/MS) and the sum of PCB by calculation from measured values
PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180
sum of PCB (calculated)
Regulated area: 4 Organic chemistry
SOP OV 333 (ČSN EN ISO 6468)
226 Water, bottled water, extracts Determination of volatile organic compounds (VOC) by gas chromatography (GC/MS/FID/ECD) and the sum of VOC by calculation from measured values
sum of VOC (calculated)
Regulated area: 4 Organic chemistry
SOP OV 344 (ČSN EN ISO 15680)
227 Water, bottled water Determination of hydrocarbons C10 to C40 by gas chromatography (GC/FID)
Regulated area: 4 Organic chemistry
SOP OV 338 (ČSN EN ISO 9377-2)
228 Drinking, bottled, ground and surface water Determination of specified polar pesticides by liquid chromatography (LC/MS/MS) and the sum of pesticides by calculation from measured values
sum of pesticides (calculated)
Regulated area: 4 Organic chemistry
SOP OV 341.02 (EPA Method 535; EPA Method 536)
229 Drinking and ground water, bottled water Determination of per- and poly-fluorinated alkyl substances (PFAS) by liquid chromatography (LC/MS/MS) and their sum by calculation from measured values
perfluorobutanoic acid (PFBA) perfluorobutanesulfonic acid (PFBS) perfluorodecanoic acid (PFDA) perfluorododecanoic acid (PFDoDA) perfluorododecanesulfonic acid (PFDoS) perfluorodecanesulfonic acid (PFDS) perfluoroheptanoic acid (PFHpA) perfluoroheptanesulfonic acid (PFHpS) perfluorohexanoic acid (PFHxA) perfluorohexanesulfonic acid (PFHxS) perfluorononanoic acid (PFNA) perfluorononanesulfonic acid (PFNS) perfluorooctanoic acid (PFOA) perfluorooctanesulfonic acid (PFOS) perfluoropentanoic acid (PFPA) perfluoropentanesulfonic acid (PFPS) perfluorotridecanoic acid (PFTrDA) perfluorotridecanesulfonic acid (PFTrDS) perfluoroundecanoic acid (PFUnDA) perfluoroundecanesulfonic acid (PFUnDS)
selected sums (calculated)
Regulated area: 4 Organic chemistry
SOP OV 385 (ČSN EN 17892)
230 Indoor, outdoor and workplace air Determination of dust and solid pollutants by gravimetry
Regulated area: 5 Air
SOP OV 403
231 Workplace air Preliminary determination of gases and vapours by detection tubes
ammonia (NH3) chlorine (Cl2) nitrogen dioxide (NO2) nitric oxide (NO) hydrogen sulphide (H2S) sulphur dioxide (SO2) hydrogen cyanide (HCN) carbon dioxide (CO2) ozone (O3) carbon monoxide (CO) carbon disulphide (CS2) phenol nitrous gases (NOx) hydrogen (H2) hydrogen peroxide (H2O2)
Regulated area: 5 Air
SOP OV 424 (manuály firmy GASTEC a Dräger)
232 Indoor, outdoor and workplace air, compressed gases Measurement of concentration of gaseous pollutants – electrochemical method
sulphur dioxide (SO2) hydrogen sulphide (H2S) carbon monoxide (CO) nitric oxide (NO) nitrogen dioxide (NO2) oxygen (O2) ammonia (NH3)
Regulated area: 5 Air
SOP OV 438
233 Indoor, outdoor and workplace air, compressed gases Determination of carbon monoxide (CO) and carbon dioxide (CO2) with an infrared spectrometry analyzer
carbon monoxide (CO) carbon dioxide (CO2)
Regulated area: 5 Air
SOP OV 438.07
234 Indoor and workplace air Determination of vapours and gases by calculation from specified values
Regulated area: 5 Air
SOP OV 486 (Nařízení vlády č. 361/2007 Sb.; Vyhláška 43/2025 Sb.)
235 Working and non-working environment Measurement and calculation of noise
Regulated area: 6 Physical factors
Měření SOP OV 456, část 1; Výpočet SOP OV 456, část 2
236 Working and non-working environment Measurement of vibration
Regulated area: 6 Physical factors
SOP OV 471
237 Working and non-working environment, roads Measurement of electrical lighting
Regulated area: 6 Physical factors
SOP OV 469
238 Working and non-working environment Measurement of daylight
Regulated area: 6 Physical factors
SOP OV 470
239 Water, bottled water Detection and enumeration of coliform bacteria and Escherichia coli by membrane filtration method
Regulated area: 9 Microbiology
SOP OV 900 (ČSN EN ISO 9308-1)
240 Water, bottled water Detection and enumeration of thermotolerant coliform bacteria – Membrane filtration method
Regulated area: 9 Microbiology
SOP OV 903 (ČSN 75 7835)
241 Water, bottled water Detection and enumeration of intestinal enterococci – Membrane filtration method
Regulated area: 9 Microbiology
SOP OV 906 (ČSN EN ISO 7899-2)
242 Water, bottled water Enumeration of culturable microorganisms by inoculation in or on a nutrient agar culture medium at: 36 °C and 22 °C
Regulated area: 9 Microbiology
SOP OV 908 (ČSN EN ISO 6222)
243 Water, bottled water Detection and enumeration of Staphylococcus aureus – Membrane filtration method
Regulated area: 9 Microbiology
SOP OV 911 (ČSN EN ISO 6888-1)
244 Water, bottled water Detection and enumeration of Legionella spp. by culture method
Regulated area: 9 Microbiology
SOP OV 913 (ČSN EN ISO 11731)
245 Water, bottled water Enumeration of sulfite-reducing clostridia – Membrane filtration method
Regulated area: 9 Microbiology
SOP OV 914 (ČSN EN 26461-2)
246 Water, bottled water Detection of Salmonella by culture method
Regulated area: 9 Microbiology
SOP OV 921 (ČSN ISO 19250)
247 Water, bottled water, purified water Detection and enumeration of Pseudomonas aeruginosa – Membrane filtration method
Regulated area: 9 Microbiology
SOP OV 909 (ČSN EN ISO 16266)
248 Drinking, bottled, surface, bathing and ground water Determination of microscopic image
Regulated area: 9 Microbiology
SOP OV 916 (ČSN 75 7712; ČSN 75 7713; ČSN 75 7717)
249 Water Enumeration of Clostridium perfringens – membrane filtration method
Regulated area: 9 Microbiology
SOP OV 914.03 (ČSN EN ISO 14189)
250 Purified water, non-sterile products Microbiological examination of non-sterile products – by culture
Regulated area: 9 Microbiology
SOP OV 930
251 Water Enumeration of coliform bacteria and Escherichia coli by the Colilert Quanti-Tray method
Regulated area: 9 Microbiology
SOP OV 936 (ČSN EN ISO 9308-2)
252 Foods Enumeration of coliform bacteria by culture
Regulated area: 9 Microbiology
SOP OV 901 (ČSN ISO 4832)
253 Foods Enumeration of Escherichia coli by culture
Regulated area: 9 Microbiology
SOP OV 902 (ČSN ISO 16649-2)
254 Foods Detection and enumeration of Pseudomonas aeruginosa by culture
Regulated area: 9 Microbiology
SOP OV 910 (ČSN EN ISO 16266)
255 Foods Enumeration of coagulase-positive staphylococci by culture
Regulated area: 9 Microbiology
SOP OV 912 (ČSN EN ISO 6888-1)
256 Foods Enumeration of Clostridium perfringens by culture
Regulated area: 9 Microbiology
SOP OV 915 (ČSN EN ISO 15213-2)
257 Foods Enumeration of total microorganisms by culture
Regulated area: 9 Microbiology
SOP OV 917 (ČSN EN ISO 4833-1)
258 Foods Enumeration of yeasts and moulds by culture
Regulated area: 9 Microbiology
SOP OV 918 (ČSN ISO 21527-1; ČSN ISO 21527-2)
259 Foods Detection and enumeration of Enterobacteriaceae by culture
Regulated area: 9 Microbiology
SOP OV 919 (ČSN EN ISO 21528-1; ČSN EN ISO 21528-2)
260 Foods Detection of Salmonella by culture
Regulated area: 9 Microbiology
SOP OV 920 (ČSN EN ISO 6579-1)
261 Foods Detection and enumeration of Listeria monocytogenes by culture
Regulated area: 9 Microbiology
SOP OV 923 (ČSN EN ISO 11290-1; ČSN EN ISO 11290-2)
262 Foods Enumeration of presumptive Bacillus cereus by culture
Regulated area: 9 Microbiology
SOP OV 925 (ČSN EN ISO 7932)
263 Waste, solid samples Enumeration of thermotolerant coliform bacteria and Escherichia coli by culture
Regulated area: 9 Microbiology
SOP OV 904 (AHEM 1/2008)
264 Waste, solid samples Enumeration of enterococci by culture
Regulated area: 9 Microbiology
SOP OV 907 (AHEM 1/2008)
265 Waste, solid samples Detection of Salmonella by culture
Regulated area: 9 Microbiology
SOP OV 922 (AHEM 1/2008)
266 Surfaces, surfaces of objects, packaging, articles of common use Determination of microbial contamination by culture
Regulated area: 9 Microbiology
SOP OV 927 (ČSN 56 0100:1970, kapitola VIII, články 144-148)
267 Indoor, outdoor and workplace air, compressed gases Determination of microbial contamination by culture
Regulated area: 9 Microbiology
SOP OV 928 (AHEM 1/2002; AHEM 4/2021)
268 Sterile and non-sterile products, surfaces Determination of microbial contamination by culture
Regulated area: 9 Microbiology
SOP OV 929.01 (AHEM 7/1992)
269 Sterile products Sterility test by culture
Regulated area: 9 Microbiology
SOP OV 929 (ČL, část 2.6.1)
270 Biological indicators Examination of biological indicators by culture
Regulated area: 9 Microbiology
SOP OV 933 (AHEM 1/2014)
271 Sterilizers Verification of the efficiency of sterilizers using chemical tests
Regulated area: 9 Microbiology
SOP OV 933.01
272 Washer-disinfectors Verification of the efficiency of washer-disinfectors using chemical tests
Regulated area: 9 Microbiology
SOP OV 933.02
273 Drinking and hot water Sampling of drinking water
Regulated area: Sampling
SOP VZ OV 001 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
274 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP VZ OV 002 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; ČSN 75 7717; Vyhláška č. 238/2011 Sb.)
275 Ground water Sampling of ground water – manual sampling and sampling by pumping
Regulated area: Sampling
SOP VZ OV 003 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)
276 Surface water Sampling from reservoirs, rivers and streams
Regulated area: Sampling
SOP VZ OV 005 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
277 Waste water Sampling of waste water – manual sampling and sampling with an automatic sampler
Regulated area: Sampling
SOP VZ OV 006 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
278 Swabs Swab sampling for detection of Legionella
Regulated area: Sampling
SOP VZ OV 012 (EU Guidelines 2017)
279 Outdoor and indoor air, compressed gases Sampling of outdoor and indoor air and compressed gases on a solid sorbent (filter, filter and PUF, sorption tube)
Regulated area: Sampling
SOP VZ OV 109 (Zákon o ochraně ovzduší 201/2012 Sb.; ČSN EN 12341; ČSN EN ISO 16000-7; Vyhláška č. 330/2012 Sb.)
280 Outdoor and indoor air Sampling of outdoor and indoor air onto culture media
Regulated area: Sampling
SOP VZ OV 109.03 (AHEM 1/2002; AHEM 4/2021)
281 Workplace air Sampling of workplace air on a solid sorbent (filter, filter and PUF, filter and sorbent, sorption tube)
Regulated area: Sampling
SOP VZ OV 110 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007Sb.)
282 Workplace air Sampling of workplace air into liquid (fritted absorbers with absorption solution)
Regulated area: Sampling
SOP VZ OV 110.01 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007 Sb.)
283 Workplace air Sampling of workplace air into canisters
Regulated area: Sampling
SOP VZ OV 110.02 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007 Sb.)
284 Waste (solid and liquid waste, biodegradable waste) Sampling of waste
Regulated area: Sampling
SOP VZ OV 201 (ČSN EN 14899; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5)
285 Sand Sampling of sand from sandpits and outdoor playgrounds
Regulated area: Sampling
SOP VZ OV 204 (Pokyn hlavního hygienika ČR k zajištění jednotného postupu při kontrolách pískovišť venkovních hracích ploch, č.j. 3209/2014 ze dne 12.3.2014)
286 Solid samples (soils, sands, sediments, sludges) Sampling of solid samples
Regulated area: Sampling
SOP VZ OV 218 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN 01 5110; ČSN 01 5111; ČSN 01 5112)
287 Foods Sampling of foods for microbiological testing
Regulated area: Sampling
SOP VZ OV 200 (ČSN P CEN ISO/TS 17728)
288 Surfaces, skin Sampling from surfaces of objects for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 206 (ČSN EN ISO 18593)
289 Sterilizers Sampling with biological and non-biological systems for verification of sterilizer efficiency
Regulated area: Sampling
SOP VZ OV 213 (AHEM 1/2014)
290 Surfaces, sterile and non-sterile products, skin Sampling and swabbing for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 214 (AHEM 7/1992)
Jihlava
291 Drinking, ground, surface and bathing water, extracts Determination of absorbance
Regulated area: 1 Basic chemistry
SOP OV 001 (ČSN 75 7360)
292 Water, bottled water, extracts Determination of ammonium by spectrophotometry and ammonia nitrogen by calculation from measured values
ammonia nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 002 (ČSN ISO 7150-1)
293 Waste, solid samples Determination of ammonium by spectrophotometry and ammonia nitrogen by calculation from measured values
ammonia nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 002.01 (JPP ÚKZÚZ, Analýza půd III; ČSN ISO 7150-1)
294 Water, purified water, bottled water, extracts Determination of anions by ion chromatography (conductivity detection)
fluorides chlorides nitrites nitrates phosphates sulphates bromates chlorites chlorates
nitrite nitrogen (calculated), nitrate nitrogen (calculated), phosphorus pentoxide (P2O5) (calculated), sum of chlorates and chlorites (calculated)
Regulated area: 1 Basic chemistry
SOP OV 003 (ČSN EN ISO 15061; ČSN EN ISO 10304-1; ČSN EN ISO 10304-4)
295 Workplace and outdoor air, emissions Determination of anions by ion chromatography (conductivity detection)
fluorides chlorides nitrates phosphates sulphates
HF (hydrogen fluoride) (calculated), HCl (hydrogen chloride, hydrochloric acid) (calculated), HNO3 (nitric acid) (calculated), H3PO4 (phosphoric acid) (calculated), H2SO4 (sulphuric acid) (calculated), SO3 (sulphur trioxide) (calculated)
Regulated area: 1 Basic chemistry
SOP OV 003.01 (ČSN EN ISO 10304-1)
296 Surface, ground, waste and process water, drinking water Determination of biochemical oxygen demand after n days (BODn) – with oxygen electrode
Regulated area: 1 Basic chemistry
SOP OV 005 (ČSN EN ISO 5815-1; ČSN EN 1899-2)
297 Waste, solid samples Determination of total nitrogen by spectrophotometry (modified Kjeldahl method)
Regulated area: 1 Basic chemistry
SOP OV 006.06 (ČSN ISO 11261)
298 Waste, ground, process, surface and drinking water Determination of total nitrogen by electrochemical method, inorganic and organic nitrogen by calculation from measured values
inorganic nitrogen (calculated), organic nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 006.05 (ČSN EN ISO 20236)
299 Water, purified water, bottled water, extracts Determination of total phosphorus, phosphate by spectrophotometry and phosphorus pentaoxide by calculation from measured values
total phosphorus phosphate
phosphorus pentaoxide (calculated)
Regulated area: 1 Basic chemistry
SOP OV 007 (ČSN EN ISO 6878)
300 Water Determination of total phosphorus by spectrophotometry with HACH set
Regulated area: 1 Basic chemistry
SOP OV 007.03 (návod firmy HACH)
301 Waste, solid samples Determination of nitrate by ion chromatography and nitrate nitrogen by calculation from measured values
nitrate nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 003.02 (JPP ÚKZÚZ, Analýza půd III; ČSN EN ISO 10304-1)
302 Water, purified water, bottled water, extracts Determination of electrical conductivity
Regulated area: 1 Basic chemistry
SOP OV 011 (ČSN EN 27888)
303 Water, bottled water, extracts Determination of aggressive carbon dioxide by Heyer marble test by titration and calculation of the forms of carbon dioxide (CO2 free, bound, total, hydrogencarbonates (HCO3-) and carbonates (CO32-)) from ANC and BNC values
aggressive carbon dioxide
forms of carbon dioxide (calculated)
Regulated area: 1 Basic chemistry
SOP OV 013 (ČSN 75 7373)
304 Drinking, surface, ground and bottled water Determination of humic substances by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 014 (ČSN 75 7536)
305 Water Determination of chemical oxygen demand using dichromate (CODCr) by spectrophotometry with HACH set
Regulated area: 1 Basic chemistry
SOP OV 015.02 (ČSN ISO 15705; návod firmy HACH)
306 Drinking, ground, surface, bathing and hot water, bottled water, extracts Titrimetric determination of chemical oxygen demand using permanganate (CODMn)
Regulated area: 1 Basic chemistry
SOP OV 016 (ČSN EN ISO 8467)
307 Surface and bathing water Preliminary sensory analysis
appearance (algal bloom, waste pollution, natural pollution) transparency
Regulated area: 1 Basic chemistry
SOP OV 062.01 (ČSN 75 7340)
308 Surface water Determination of chlorophyll-a by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 019 (ČSN ISO 10260)
309 Drinking, ground, surface, waste and process water, bottled water, extracts Determination of chrome (VI) by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 049 (ČSN ISO 11083; ČSN EN ISO 18412; ČSN EN ISO 17075-1)
310 Workplace and outdoor air, emissions Determination of chrome (VI) by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 049.02 (NIOSH Manual of Analytical Metods (NMAM), 8/1594)
311 Water, bottled water, extracts Determination of total cyanide by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 022.01 (ČSN 75 7415, postup A)
312 Water, bottled water, extracts Determination of acid neutralizing capacity (ANC) by titration
Regulated area: 1 Basic chemistry
SOP OV 024 (ČSN EN ISO 9963-1)
313 Drinking, surface, ground, waste and process water Determination of suspended solids at 105 °C and 550 °C (annealing residue), total solids at 105 °C and 550 °C (annealing residue) by gravimetry and loss on ignition of suspended solids and total solids by calculation from measured values
suspended solids total solids
loss on ignition of suspended solids and total solids (calculated)
Regulated area: 1 Basic chemistry
SOP OV 025.01 (ČSN EN 872; ČSN 75 7350)
314 Water, bottled water, extracts Determination of dissolved solids (RL, RAS) by gravimetric method and total mineralization by calculation from measured values
total mineralization (calculated)
Regulated area: 1 Basic chemistry
SOP OV 026.01 (ČSN 75 7346; ČSN 75 7347; ČSN 75 7358; ČSN EN 15216)
315 Drinking, hot, bottled, surface and ground water Preliminary sensory analysis – odour and flavour
Regulated area: 1 Basic chemistry
SOP OV 062 (ČSN 75 7340)
316 Water, purified water, extracts, bottled water Determination of pH by potentiometry
Regulated area: 1 Basic chemistry
SOP OV 033 (ČSN ISO 10523)
317 Waste, solid samples Determination of pH by potentiometry
Regulated area: 1 Basic chemistry
SOP OV 033.01 (ČSN EN ISO 10390)
318 Waste, solid samples, materials Determination of dry matter by gravimetry and water content (moisture) by calculation from measured values
water content (moisture) (calculated)
Regulated area: 1 Basic chemistry
SOP OV 040.01 (ČSN EN 15934, metoda A)
319 Water, bottled water Determination of anionic surfactants by spectrophotometry
Regulated area: 1 Basic chemistry
SOP OV 041 (ČSN EN 903)
320 Drinking, hot, bottled, surface, ground and bathing water, purified water, extracts Determination of turbidity by nephelometry
Regulated area: 1 Basic chemistry
SOP OV 044.01 (ČSN EN ISO 7027-1)
321 Water, bottled water, extracts Determination of base neutralizing capacity (BNC) by titration
Regulated area: 1 Basic chemistry
SOP OV 045 (ČSN 75 7372)
322 Waste, solid samples Determination of loss on ignition (combustible matter) by gravimetry and annealing residue by calculation from measured values
annealing residue (calculated)
Regulated area: 1 Basic chemistry
SOP OV 040.02 (ČSN 46 5735; ČSN EN 15935)
323 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of ammonium by photometry using automatic analyzer and ammonia nitrogen by calculation from measured values
ammonia nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 064 (návod firmy Thermo Scientific)
324 Waste and process water, extracts Determination of ammonium by photometry using automatic analyzer and ammonia nitrogen by calculation from measured values
ammonia nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 064.07 (návod firmy Thermo Scientific)
325 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of colour by photometry using automatic analyzer
Regulated area: 1 Basic chemistry
SOP OV 064.02 (návod firmy Thermo Scientific)
326 Drinking, ground, bottled, surface, bathing, process and hot water, purified water Determination of boron by photometry using automatic analyzer
Regulated area: 1 Basic chemistry
SOP OV 064.08 (návod firmy Thermo Scientific)
327 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of nitrate by photometry using automatic analyzer and nitrate nitrogen by calculation from measured values
nitrate nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 064.03 (návod firmy Thermo Scientific)
328 Waste and process water, extracts Determination of nitrate by photometry using automatic analyzer and nitrate nitrogen by calculation from measured values
nitrate nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 064.09 (návod firmy Thermo Scientific)
329 Drinking, hot, bottled, bathing, surface and ground water, purified water, extracts of materials Determination of nitrite by photometry using automatic analyzer and nitrite nitrogen by calculation from measured values
nitrite nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 064.04 (návod firmy Thermo Scientific)
330 Waste and process water, extracts Determination of nitrite by photometry using automatic analyzer and nitrite nitrogen by calculation from measured values
nitrite nitrogen (calculated)
Regulated area: 1 Basic chemistry
SOP OV 064.11 (návod firmy Thermo Scientific)
331 Drinking, hot, bottled, bathing, surface and ground water, purified water Determination of pH by potentiometry using automatic analyzer
Regulated area: 1 Basic chemistry
SOP OV 064.12 (návod firmy Thermo Scientific)
332 Drinking, hot, bottled, bathing, surface and ground water, purified water Determination of electric conductivity using automatic analyzer
Regulated area: 1 Basic chemistry
SOP OV 064.13 (návod firmy Thermo Scientific)
333 Drinking, ground, surface, bathing, waste and process water Determination of dissolved oxygen, method with optical sensor
Regulated area: 1 Basic chemistry
SOP OV 036.01 (ČSN ISO 17289; návod firmy WTW)
334 Water, purified water Determination of total and free chlorine by spectrophotometry by HACH set and bound chlorine by calculation from measured values
total chlorine free chlorine
bound chlorine (calculated)
Regulated area: 1 Basic chemistry
SOP OV 008.01 (návod firmy HACH)
335 Drinking, ground, bathing and purified water, waste and process water Determination of chlorine dioxide by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 018.01 (návod firmy HACH/MERCK)
336 Drinking, bathing, ground and surface water Determination of redox potential
Regulated area: 1 Basic chemistry
SOP OV 028 (ČSN 75 7367)
337 Bathing water, drinking water Determination of ozone by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 032.02 (návod firmy HACH/MERCK)
338 Water, purified water Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042 (ČSN 75 7342)
339 Foods Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042.01 (ČSN EN 13485)
340 Purified water Determination of electrical conductivity
Regulated area: 1 Basic chemistry
SOP OV 055.01 (ČL, článek A, 11.4:0008)
341 Purified water Determination of evaporation residue by gravimetry
Regulated area: 1 Basic chemistry
SOP OV 055.02 (ČL, článek A, 11.4:0008)
342 Indoor, outdoor and workplace air, emissions Determination of gaseous pollutants by spectrophotometry
ammonia (NH3) formaldehyde (HCHO)
Regulated area: 1 Basic chemistry
SOP OV 058
343 Water, purified water, bottled water, extracts, dialysates from DGT samplers Determination of elements by ICP-MS method
silver (Ag) aluminium (Al) arsenic (As) boron (B) barium (Ba) beryllium (Be) calcium (Ca) cadmium (Cd) cobalt (Co) total chromium (Cr) copper (Cu) iron (Fe) potassium (K) lithium (Li) magnesium (Mg) manganese (Mn) molybdenum (Mo) sodium (Na) nickel (Ni) phosphorus (P) lead (Pb) antimony (Sb) selenium (Se) silicon (Si) tin (Sn) strontium (Sr) thallium (Tl) uranium (U) vanadium (V) zinc (Zn)
SiO2 (calculated), hardness (Ca+Mg, CaCO3) (calculated)
Regulated area: 3 Metals
SOP OV 201 (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)
344 Waste, solid samples, materials Determination of elements by ICP-MS method
arsenic (As) barium (Ba) beryllium (Be) calcium (Ca) cadmium (Cd) cobalt (Co) chromium (Cr) copper (Cu) phosphorus (P) potassium (K) molybdenum (Mo) magnesium (Mg) nickel (Ni) lead (Pb) vanadium (V) zinc (Zn)
Regulated area: 3 Metals
SOP OV 201.05 (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)
345 Indoor, outdoor and workplace air, emissions Determination of elements by ICP-MS method
lead (Pb) chromium (Cr) nickel (Ni) manganese (Mn) zinc (Zn)
Regulated area: 3 Metals
SOP OV 201.04 (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; ČSN EN 14902)
346 Water, bottled water, purified water, extracts, dialysates from DGT samplers Determination of elements by ICP-OES method
silver (Ag) aluminium (Al) arsenic (As) boron (B) barium (Ba) beryllium (Be) calcium (Ca) cadmium (Cd) cobalt (Co) copper (Cu) total chromium (Cr) iron (Fe) potassium (K) magnesium (Mg) manganese (Mn) molybdenum (Mo) sodium (Na) nickel (Ni) phosphorus (P) lead (Pb) selenium (Se) antimony (Sb) tin (Sn) vanadium (V) zinc (Zn)
P2O5 (calculated), hardness (Ca+Mg, CaCO3) (calculated)
Regulated area: 3 Metals
SOP OV 201.01 (ČSN EN ISO 11885)
347 Waste, solid samples, materials Determination of elements by ICP-OES method
arsenic (As) barium (Ba) beryllium (Be) calcium (Ca) cadmium (Cd) cobalt (Co) copper (Cu) total chromium (Cr) potassium (K) magnesium (Mg) molybdenum (Mo) nickel (Ni) phosphorus (P) lead (Pb) vanadium (V) zinc (Zn)
K2O (calculated), P2O5 (calculated), CaO (calculated), MgO (calculated)
Regulated area: 3 Metals
SOP OV 201.06 (ČSN EN ISO 11885)
348 Water, bottled and purified water, extracts, waste, solid samples, indoor, outdoor and workplace air, mineral oils, dialysates from DGT samplers, emissions, feedingstuffs, foods, materials Determination of mercury by single purpose atomic absorption spectrometer
Regulated area: 3 Metals
SOP OV 200.03 (ČSN 75 7440)
349 Water Determination of bisphenol A by gas chromatography (GC/MS)
Regulated area: 4 Organic chemistry
SOP OV 302 (ČSN EN ISO 18857-2; ČSN EN 12673)
350 Water, bottled water, purified water, extracts Determination of total organic carbon (TOC) and dissolved organic carbon (DOC) by infrared spectrometry method
total organic carbon (TOC) dissolved organic carbon (DOC)
Regulated area: 4 Organic chemistry
SOP OV 307 (ČSN EN 1484)
351 Water, bottled water, extracts Determination of NEL (non-polar extractives) and EL (extractives) by infrared spectrometry
NEL (non-polar extractives) EL (extractives)
Regulated area: 4 Organic chemistry
SOP OV 309.01 (ČSN 75 7505:1998; ČSN 75 7506)
352 Surface, waste, bathing and process water, extracts Determination of fats and oils by gravimetry
Regulated area: 4 Organic chemistry
SOP OV 360 (ČSN 75 7509)
353 Waste, solid samples Determination of organochlorinated pesticides (OCP) by gas chromatography (GC/ECD) and the sum of OCP by calculation from measured values
α-HCH β-HCH γ-HCH (lindane) HCB (hexachlorobenzene) p,p′-DDE p,p′-DDD o,p′-DDT p,p′-DDT o,p′-DDD o,p′-DDE
sum of OCP (calculated)
Regulated area: 4 Organic chemistry
SOP OV 327.01 (EPA Method 8081)
354 Water, bottled water, extracts Determination of polyaromatic hydrocarbons (PAH) by liquid chromatography (LC/FLD/DAD) and the sum of PAH by calculation from measured values
acenaphthene acenaphthylene anthracene benzo(a)anthracene benzo(a)pyrene benzo(b)fluoranthene benzo(ghi)perylene benzo(k)fluoranthene dibenzo(ah)anthracene phenanthrene fluoranthene fluorene chrysene indeno(1,2,3-cd)pyrene naphthalene pyrene
sum of PAH (calculated)
Regulated area: 4 Organic chemistry
SOP OV 331 (ČSN EN ISO 17993)
355 Waste, solid samples Determination of polyaromatic hydrocarbons (PAH) by liquid chromatography (LC/FLD/DAD) and the sum of PAH by calculation from measured values
acenaphthene acenaphthylene anthracene benzo(a)anthracene benzo(a)pyrene benzo(b)fluoranthene benzo(ghi)perylene benzo(k)fluoranthene dibenzo(ah)anthracene phenanthrene fluoranthene fluorene chrysene indeno(1,2,3-cd)pyrene naphthalene pyrene
sum of PAH (calculated)
Regulated area: 4 Organic chemistry
SOP OV 331.05 (ČSN EN 17503)
356 Indoor, outdoor and workplace air, emissions Determination of polyaromatic hydrocarbons (PAH) by liquid chromatography (LC/FLD/DAD) and the sum of PAH by calculation from measured values
acenaphthene acenaphthylene anthracene benzo(a)anthracene benzo(a)pyrene benzo(b)fluoranthene benzo(ghi)perylene benzo(k)fluoranthene dibenzo(ah)anthracene phenanthrene fluoranthene fluorene chrysene indeno(1,2,3-cd)pyrene naphthalene pyrene benzo(j)fluoranthene
sum of PAH (calculated)
Regulated area: 4 Organic chemistry
SOP OV 331.02 (EPA TO 13; ČSN EN 15549)
357 Water, bottled water, extracts Determination of polychlorinated biphenyls (PCB) by gas chromatography (GC/ECD/MS) and the sum of PCB by calculation from measured values
PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180
sum of PCB (calculated)
Regulated area: 4 Organic chemistry
SOP OV 333 (ČSN EN ISO 6468)
358 Waste, solid samples, mineral oils, materials Determination of polychlorinated biphenyls (PCB) by gas chromatography (GC/ECD) and the sum of PCB by calculation from measured values
PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180
sum of PCB (calculated)
Regulated area: 4 Organic chemistry
SOP OV 333.06 (ČSN EN 12766-1; ČSN EN ISO 18475)
359 Water, bottled water, extracts Determination of volatile organic compounds (VOC) by gas chromatography (GC/MS/FID/ECD) and the sum of VOC by calculation from measured values
sum of VOC (calculated)
Regulated area: 4 Organic chemistry
SOP OV 344 (ČSN EN ISO 15680)
360 Waste, solid samples Determination of volatile organic compounds (VOC) by gas chromatography (GC/MS) and the sum of VOC by calculation from measured values
sum of VOC (calculated)
Regulated area: 4 Organic chemistry
SOP OV 344.01 (ČSN EN ISO 15009)
361 Indoor, outdoor and workplace air, emissions Determination of volatile organic compounds (VOC) and other organic compounds by gas chromatography on a sorbent (GC/FID/MS/ECD) and the sum of VOC by calculation from measured values
sum of VOC (calculated)
Regulated area: 4 Organic chemistry
SOP OV 344.12 (ČSN P CEN/TS 13649; ČSN EN 14662-2)
362 Water, bottled water Determination of hydrocarbons C10 to C40 by gas chromatography (GC/FID)
Regulated area: 4 Organic chemistry
SOP OV 338 (ČSN EN ISO 9377-2)
363 Waste, solid samples Determination of hydrocarbons C10 to C40 by gas chromatography (GC/FID)
Regulated area: 4 Organic chemistry
SOP OV 338.01 (ČSN EN 14039)
364 Indoor, outdoor and workplace air Determination of dust and solid pollutants by gravimetry
Regulated area: 5 Air
SOP OV 403
365 Workplace air Preliminary determination of gases and vapours by detection tubes
ammonia (NH3) chlorine (Cl2) nitrogen dioxide (NO2) nitric oxide (NO) hydrogen sulphide (H2S) sulphur dioxide (SO2) hydrogen cyanide (HCN) carbon dioxide (CO2) ozone (O3) carbon monoxide (CO) carbon disulphide (CS2) phenol nitrous gases (NOx) hydrogen (H2) hydrogen peroxide (H2O2)
Regulated area: 5 Air
SOP OV 424 (manuály firmy GASTEC a Dräger)
366 Indoor, outdoor and workplace air Measurement of the concentration of dust by automatic analyzers – optical method
Regulated area: 5 Air
SOP OV 436 (ČSN EN 16450)
367 Indoor, outdoor and workplace air, compressed gases Measurement of concentration of gaseous pollutants – electrochemical method
sulphur dioxide (SO2) hydrogen sulphide (H2S) carbon monoxide (CO) nitric oxide (NO) nitrogen dioxide (NO2) oxygen (O2) ammonia (NH3)
Regulated area: 5 Air
SOP OV 438
368 Indoor, outdoor and workplace air Determination of ozone (O3) by UV absorption
Regulated area: 5 Air
SOP OV 438.04 (ČSN EN 14625)
369 Indoor and outdoor air Determination of nitrogen oxides by chemiluminescence
Regulated area: 5 Air
SOP OV 438.05 (ČSN EN 14211)
370 Indoor, outdoor and workplace air, compressed gases Determination of carbon monoxide (CO) and carbon dioxide (CO2) with an infrared spectrometry analyzer
carbon monoxide (CO) carbon dioxide (CO2)
Regulated area: 5 Air
SOP OV 438.07
371 Indoor air, cleanrooms and clean zones Enumeration of particles – optical method
size fractions from 0.30 to 25.0 µm
Regulated area: 5 Air
SOP OV 436.03 (ČSN EN ISO 14644-1; VYR-32 doplněk 1)
372 Indoor and workplace air Determination of vapours and gases by calculation from specified values
Regulated area: 5 Air
SOP OV 486 (Nařízení vlády č. 361/2007 Sb.; Vyhláška 43/2025 Sb.)
373 Working and non-working environment Measurement and calculation of noise
Regulated area: 6 Physical factors
Měření SOP OV 456, část 1; Výpočet SOP OV 456, část 2
374 Working and non-working environment, roads Measurement of electrical lighting
Regulated area: 6 Physical factors
SOP OV 469
375 Working and non-working environment Measurement of daylight
Regulated area: 6 Physical factors
SOP OV 470
376 Working and non-working environment, cleanrooms and clean zones Measurement of microclimatic conditions
globe temperature air temperature relative air humidity air velocity
operative temperature (calculated)
Regulated area: 6 Physical factors
SOP OV 474
377 Drinking and ground water Determination of gross alpha activity by measurement of evaporation residue with ZnS (Ag) scintillator
Regulated area: 8 Radiology
SOP OV 806 (ČSN 75 7611, kap. 4)
378 Drinking and ground water Determination of gross beta activity by beta particles measurement in ignited evaporation residue by a window proportional counter
Regulated area: 8 Radiology
SOP OV 807 (ČSN 75 7612)
379 Drinking and ground water Determination of 222Rn volume activity by measurement of gamma radiation using a scintillation counter
Regulated area: 8 Radiology
SOP OV 808 (ČSN 75 7624, kap. 6)
380 Water, bottled water Detection and enumeration of coliform bacteria and Escherichia coli by membrane filtration method
Regulated area: 9 Microbiology
SOP OV 900 (ČSN EN ISO 9308-1)
381 Water, bottled water Detection and enumeration of thermotolerant coliform bacteria – Membrane filtration method
Regulated area: 9 Microbiology
SOP OV 903 (ČSN 75 7835)
382 Water, bottled water Detection and enumeration of intestinal enterococci – Membrane filtration method
Regulated area: 9 Microbiology
SOP OV 906 (ČSN EN ISO 7899-2)
383 Water, bottled water Enumeration of culturable microorganisms by inoculation in or on a nutrient agar culture medium at: 36 °C and 22 °C
Regulated area: 9 Microbiology
SOP OV 908 (ČSN EN ISO 6222)
384 Water, bottled water Detection and enumeration of Staphylococcus aureus – Membrane filtration method
Regulated area: 9 Microbiology
SOP OV 911 (ČSN EN ISO 6888-1)
385 Water, bottled water Detection and enumeration of Legionella spp. by culture method
Regulated area: 9 Microbiology
SOP OV 913 (ČSN EN ISO 11731)
386 Water, bottled water Enumeration of sulfite-reducing clostridia – Membrane filtration method
Regulated area: 9 Microbiology
SOP OV 914 (ČSN EN 26461-2)
387 Water, bottled water Detection of Salmonella by culture method
Regulated area: 9 Microbiology
SOP OV 921 (ČSN ISO 19250)
388 Water, bottled water, purified water Detection and enumeration of Pseudomonas aeruginosa – Membrane filtration method
Regulated area: 9 Microbiology
SOP OV 909 (ČSN EN ISO 16266)
389 Drinking, bottled, surface, bathing and ground water Determination of microscopic image
Regulated area: 9 Microbiology
SOP OV 916 (ČSN 75 7712; ČSN 75 7713; ČSN 75 7717)
390 Water Enumeration of Clostridium perfringens – membrane filtration method
Regulated area: 9 Microbiology
SOP OV 914.03 (ČSN EN ISO 14189)
391 Purified water, non-sterile products Microbiological examination of non-sterile products – by culture
Regulated area: 9 Microbiology
SOP OV 930
392 Purified water Detection of bacterial endotoxins by LAL test (gel-clot method)
Regulated area: 9 Microbiology
SOP OV 931 (ČL, část 2.6.14)
393 Water Enumeration of coliform bacteria and Escherichia coli by the Colilert Quanti-Tray method
Regulated area: 9 Microbiology
SOP OV 936 (ČSN EN ISO 9308-2)
394 Foods Enumeration of coliform bacteria by culture
Regulated area: 9 Microbiology
SOP OV 901 (ČSN ISO 4832)
395 Foods Enumeration of Escherichia coli by culture
Regulated area: 9 Microbiology
SOP OV 902 (ČSN ISO 16649-2)
396 Foods Detection and enumeration of Pseudomonas aeruginosa by culture
Regulated area: 9 Microbiology
SOP OV 910 (ČSN EN ISO 16266)
397 Foods Enumeration of coagulase-positive staphylococci by culture
Regulated area: 9 Microbiology
SOP OV 912 (ČSN EN ISO 6888-1)
398 Foods Enumeration of Clostridium perfringens by culture
Regulated area: 9 Microbiology
SOP OV 915 (ČSN EN ISO 15213-2)
399 Foods Enumeration of total microorganisms by culture
Regulated area: 9 Microbiology
SOP OV 917 (ČSN EN ISO 4833-1)
400 Foods Enumeration of yeasts and moulds by culture
Regulated area: 9 Microbiology
SOP OV 918 (ČSN ISO 21527-1; ČSN ISO 21527-2)
401 Foods Enumeration of potentially toxinogenic moulds by culture
Regulated area: 9 Microbiology
SOP OV 918.01 (AHEM 1/2003)
402 Foods Detection and enumeration of Enterobacteriaceae by culture
Regulated area: 9 Microbiology
SOP OV 919 (ČSN EN ISO 21528-1; ČSN EN ISO 21528-2)
403 Foods Detection of Salmonella by culture
Regulated area: 9 Microbiology
SOP OV 920 (ČSN EN ISO 6579-1)
404 Foods Detection and enumeration of Listeria monocytogenes by culture
Regulated area: 9 Microbiology
SOP OV 923 (ČSN EN ISO 11290-1; ČSN EN ISO 11290-2)
405 Foods Detection and enumeration of Campylobacter by culture
Regulated area: 9 Microbiology
SOP OV 924 (ČSN EN ISO 10272-1; ČSN EN ISO 10272-2)
406 Foods Enumeration of presumptive Bacillus cereus by culture
Regulated area: 9 Microbiology
SOP OV 925 (ČSN EN ISO 7932)
407 Waste, solid samples Enumeration of thermotolerant coliform bacteria and Escherichia coli by culture
Regulated area: 9 Microbiology
SOP OV 904 (AHEM 1/2008)
408 Waste, solid samples Enumeration of enterococci by culture
Regulated area: 9 Microbiology
SOP OV 907 (AHEM 1/2008)
409 Waste, solid samples Detection of Salmonella by culture
Regulated area: 9 Microbiology
SOP OV 922 (AHEM 1/2008)
410 Surfaces, surfaces of objects, packaging, articles of common use Determination of microbial contamination by culture
Regulated area: 9 Microbiology
SOP OV 927 (ČSN 56 0100:1970, kapitola VIII, články 144-148)
411 Indoor, outdoor and workplace air, compressed gases Determination of microbial contamination by culture
Regulated area: 9 Microbiology
SOP OV 928 (AHEM 1/2002; AHEM 4/2021)
412 Sterile and non-sterile products, surfaces Determination of microbial contamination by culture
Regulated area: 9 Microbiology
SOP OV 929.01 (AHEM 7/1992)
413 Sterile products Sterility test by culture
Regulated area: 9 Microbiology
SOP OV 929 (ČL, část 2.6.1)
414 Articles of common use Enumeration and detection of aerobic mesophilic bacteria by culture
Regulated area: 9 Microbiology
SOP OV 983 (ČSN EN ISO 21149)
415 Articles of common use Detection of Pseudomonas aeruginosa by culture
Regulated area: 9 Microbiology
SOP OV 984 (ČSN EN ISO 22717)
416 Articles of common use Detection of Staphylococcus aureus by culture
Regulated area: 9 Microbiology
SOP OV 985 (ČSN EN ISO 22718)
417 Articles of common use Detection of Candida albicans by culture
Regulated area: 9 Microbiology
SOP OV 986 (ČSN EN ISO 18416)
418 Articles of common use Detection of Escherichia coli by culture
Regulated area: 9 Microbiology
SOP OV 988 (ČSN EN ISO 21150)
419 Biological indicators Examination of biological indicators by culture
Regulated area: 9 Microbiology
SOP OV 933 (AHEM 1/2014)
420 Sterilizers Verification of the efficiency of sterilizers using chemical tests
Regulated area: 9 Microbiology
SOP OV 933.01
421 Washer-disinfectors Verification of the efficiency of washer-disinfectors using chemical tests
Regulated area: 9 Microbiology
SOP OV 933.02
422 Drinking, surface and ground water Enumeration of somatic coliphages
Regulated area: 9 Microbiology
SOP OV 990 (ČSN EN ISO 10705-2)
423 Drinking and hot water Sampling of drinking water
Regulated area: Sampling
SOP VZ OV 001 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
424 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP VZ OV 002 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; ČSN 75 7717; Vyhláška č. 238/2011 Sb.)
425 Ground water Sampling of ground water – manual sampling and sampling by pumping
Regulated area: Sampling
SOP VZ OV 003 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)
426 Surface water Sampling from reservoirs, rivers and streams
Regulated area: Sampling
SOP VZ OV 005 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
427 Waste water Sampling of waste water – manual sampling and sampling with an automatic sampler
Regulated area: Sampling
SOP VZ OV 006 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
428 Purified water Sampling of purified water
Regulated area: Sampling
SOP VZ OV 008 (Vyhláška č. 84/2008 Sb.)
429 Swabs Swab sampling for detection of Legionella
Regulated area: Sampling
SOP VZ OV 012 (EU Guidelines 2017)
430 Process water Sampling of process water
Regulated area: Sampling
SOP VZ OV 011 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-7; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
431 Outdoor and indoor air, compressed gases Sampling of outdoor and indoor air and compressed gases on a solid sorbent (filter, filter and PUF, sorption tube)
Regulated area: Sampling
SOP VZ OV 109 (Zákon o ochraně ovzduší 201/2012 Sb.; ČSN EN 12341; ČSN EN ISO 16000-7; Vyhláška č. 330/2012 Sb.)
432 Outdoor and indoor air Sampling of outdoor and indoor air onto culture media
Regulated area: Sampling
SOP VZ OV 109.03 (AHEM 1/2002; AHEM 4/2021)
433 Workplace air Sampling of workplace air on a solid sorbent (filter, filter and PUF, filter and sorbent, sorption tube)
Regulated area: Sampling
SOP VZ OV 110 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007Sb.)
434 Workplace air Sampling of workplace air into liquid (fritted absorbers with absorption solution)
Regulated area: Sampling
SOP VZ OV 110.01 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007 Sb.)
435 Waste (solid and liquid waste, biodegradable waste) Sampling of waste
Regulated area: Sampling
SOP VZ OV 201 (ČSN EN 14899; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5)
436 Sand Sampling of sand from sandpits and outdoor playgrounds
Regulated area: Sampling
SOP VZ OV 204 (Pokyn hlavního hygienika ČR k zajištění jednotného postupu při kontrolách pískovišť venkovních hracích ploch, č.j. 3209/2014 ze dne 12.3.2014)
437 Solid samples (soils, sands, sediments, sludges) Sampling of solid samples
Regulated area: Sampling
SOP VZ OV 218 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN 01 5110; ČSN 01 5111; ČSN 01 5112)
438 Foods Sampling of foods for microbiological testing
Regulated area: Sampling
SOP VZ OV 200 (ČSN P CEN ISO/TS 17728)
439 Surfaces, skin Sampling from surfaces of objects for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 206 (ČSN EN ISO 18593)
440 Sterilizers Sampling with biological and non-biological systems for verification of sterilizer efficiency
Regulated area: Sampling
SOP VZ OV 213 (AHEM 1/2014)
441 Surfaces, sterile and non-sterile products, skin Sampling and swabbing for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 214 (AHEM 7/1992)
Brno
442 Surface and bathing water Preliminary sensory analysis
appearance (algal bloom, waste pollution, natural pollution) transparency
Regulated area: 1 Basic chemistry
SOP OV 062.01 (ČSN 75 7340)
443 Water, purified water Determination of total and free chlorine by spectrophotometry by HACH set and bound chlorine by calculation from measured values
total chlorine free chlorine
bound chlorine (calculated)
Regulated area: 1 Basic chemistry
SOP OV 008.01 (návod firmy HACH)
444 Water Determination of pH by potentiometry
Regulated area: 1 Basic chemistry
SOP OV 033.02 (ČSN ISO 10523)
445 Drinking, ground, bathing and purified water, waste and process water Determination of chlorine dioxide by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 018.01 (návod firmy HACH/MERCK)
446 Drinking, bathing, ground and surface water Determination of redox potential
Regulated area: 1 Basic chemistry
SOP OV 028 (ČSN 75 7367)
447 Bathing water, drinking water Determination of ozone by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 032.02 (návod firmy HACH/MERCK)
448 Water, purified water Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042 (ČSN 75 7342)
449 Foods Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042.01 (ČSN EN 13485)
450 Indoor, outdoor and workplace air Determination of dust and solid pollutants by gravimetry
Regulated area: 5 Air
SOP OV 403
451 Outdoor air Determination of mass of dustfall by gravimetry
Regulated area: 5 Air
SOP OV 404
452 Workplace air Preliminary determination of gases and vapours by detection tubes
ammonia (NH3) chlorine (Cl2) nitrogen dioxide (NO2) nitric oxide (NO) hydrogen sulphide (H2S) sulphur dioxide (SO2) hydrogen cyanide (HCN) carbon dioxide (CO2) ozone (O3) carbon monoxide (CO) carbon disulphide (CS2) phenol nitrous gases (NOx) hydrogen (H2) hydrogen peroxide (H2O2)
Regulated area: 5 Air
SOP OV 424 (manuály firmy GASTEC a Dräger)
453 Indoor, outdoor and workplace air Measurement of the concentration of dust by automatic analyzers – optical method
Regulated area: 5 Air
SOP OV 436 (ČSN EN 16450)
454 Indoor, outdoor and workplace air, compressed gases Measurement of concentration of gaseous pollutants – electrochemical method
sulphur dioxide (SO2) hydrogen sulphide (H2S) carbon monoxide (CO) nitric oxide (NO) nitrogen dioxide (NO2) oxygen (O2) ammonia (NH3)
Regulated area: 5 Air
SOP OV 438
455 Indoor, outdoor and workplace air, compressed gases Determination of carbon monoxide (CO) and carbon dioxide (CO2) with an infrared spectrometry analyzer
carbon monoxide (CO) carbon dioxide (CO2)
Regulated area: 5 Air
SOP OV 438.07
456 Indoor air, cleanrooms and clean zones Enumeration of particles – optical method
size fractions from 0.30 to 25.0 µm
Regulated area: 5 Air
SOP OV 436.03 (ČSN EN ISO 14644-1; VYR-32 doplněk 1)
457 Indoor and workplace air Determination of vapours and gases by calculation from specified values
Regulated area: 5 Air
SOP OV 486 (Nařízení vlády č. 361/2007 Sb.; Vyhláška 43/2025 Sb.)
458 Working and non-working environment Measurement and calculation of noise
Regulated area: 6 Physical factors
Měření SOP OV 456, část 1; Výpočet SOP OV 456, část 2
459 Indoor spaces Measurement of reverberation time
Regulated area: 6 Physical factors
SOP OV 464 (ČSN EN ISO 3382-2; ČSN EN ISO 3382-1)
460 Building structures Measurement of airborne sound insulation
Regulated area: 6 Physical factors
SOP OV 468
461 Building structures Measurement of impact sound insulation
Regulated area: 6 Physical factors
SOP OV 468.02
462 Working and non-working environment Measurement of vibration
Regulated area: 6 Physical factors
SOP OV 471
463 Working and non-working environment, roads Measurement of electrical lighting
Regulated area: 6 Physical factors
SOP OV 469
464 Working and non-working environment Measurement of daylight
Regulated area: 6 Physical factors
SOP OV 470
465 Working and non-working environment, cleanrooms and clean zones Measurement of microclimatic conditions
globe temperature air temperature relative air humidity air velocity
operative temperature (calculated)
Regulated area: 6 Physical factors
SOP OV 474
466 Working and non-working environment Measurement of electromagnetic field
Regulated area: 6 Physical factors
SOP OV 452
467 Working and non-working environment Measurement of ultraviolet radiation parameters
Regulated area: 6 Physical factors
SOP OV 455
468 Working environment Determination of luminous flux density
Regulated area: 6 Physical factors
SOP OV 487
469 Drinking and hot water Sampling of drinking water
Regulated area: Sampling
SOP VZ OV 001 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
470 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP VZ OV 002 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; ČSN 75 7717; Vyhláška č. 238/2011 Sb.)
471 Ground water Sampling of ground water – manual sampling and sampling by pumping
Regulated area: Sampling
SOP VZ OV 003 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)
472 Surface water Sampling from reservoirs, rivers and streams
Regulated area: Sampling
SOP VZ OV 005 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
473 Waste water Sampling of waste water – manual sampling and sampling with an automatic sampler
Regulated area: Sampling
SOP VZ OV 006 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
474 Purified water Sampling of purified water
Regulated area: Sampling
SOP VZ OV 008 (Vyhláška č. 84/2008 Sb.)
475 Swabs Swab sampling for detection of Legionella
Regulated area: Sampling
SOP VZ OV 012 (EU Guidelines 2017)
476 Outdoor and indoor air, compressed gases Sampling of outdoor and indoor air and compressed gases on a solid sorbent (filter, filter and PUF, sorption tube)
Regulated area: Sampling
SOP VZ OV 109 (Zákon o ochraně ovzduší 201/2012 Sb.; ČSN EN 12341; ČSN EN ISO 16000-7; Vyhláška č. 330/2012 Sb.)
477 Outdoor and indoor air Sampling of outdoor and indoor air into liquid (sorption solution, sedimentation vessel)
Regulated area: Sampling
SOP VZ OV 109.01 (Zákon o ochraně ovzduší 201/2012 Sb.)
478 Outdoor and indoor air Sampling of outdoor and indoor air onto culture media
Regulated area: Sampling
SOP VZ OV 109.03 (AHEM 1/2002; AHEM 4/2021)
479 Workplace air Sampling of workplace air on a solid sorbent (filter, filter and PUF, filter and sorbent, sorption tube)
Regulated area: Sampling
SOP VZ OV 110 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007Sb.)
480 Workplace air Sampling of workplace air into liquid (fritted absorbers with absorption solution)
Regulated area: Sampling
SOP VZ OV 110.01 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007 Sb.)
481 Waste (solid and liquid waste, biodegradable waste) Sampling of waste
Regulated area: Sampling
SOP VZ OV 201 (ČSN EN 14899; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5)
482 Sand Sampling of sand from sandpits and outdoor playgrounds
Regulated area: Sampling
SOP VZ OV 204 (Pokyn hlavního hygienika ČR k zajištění jednotného postupu při kontrolách pískovišť venkovních hracích ploch, č.j. 3209/2014 ze dne 12.3.2014)
483 Solid samples (soils, sands, sediments, sludges) Sampling of solid samples
Regulated area: Sampling
SOP VZ OV 218 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN 01 5110; ČSN 01 5111; ČSN 01 5112)
484 Foods Sampling of foods for microbiological testing
Regulated area: Sampling
SOP VZ OV 200 (ČSN P CEN ISO/TS 17728)
485 Surfaces, skin Sampling from surfaces of objects for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 206 (ČSN EN ISO 18593)
486 Sterilizers Sampling with biological and non-biological systems for verification of sterilizer efficiency
Regulated area: Sampling
SOP VZ OV 213 (AHEM 1/2014)
487 Surfaces, sterile and non-sterile products, skin Sampling and swabbing for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 214 (AHEM 7/1992)
Karviná
488 Surface and bathing water Preliminary sensory analysis
appearance (algal bloom, waste pollution, natural pollution) transparency
Regulated area: 1 Basic chemistry
SOP OV 062.01 (ČSN 75 7340)
489 Water, purified water Determination of total and free chlorine by spectrophotometry by HACH set and bound chlorine by calculation from measured values
total chlorine free chlorine
bound chlorine (calculated)
Regulated area: 1 Basic chemistry
SOP OV 008.01 (návod firmy HACH)
490 Drinking, ground, bathing and purified water, waste and process water Determination of chlorine dioxide by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 018.01 (návod firmy HACH/MERCK)
491 Bathing water, drinking water Determination of ozone by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 032.02 (návod firmy HACH/MERCK)
492 Water, purified water Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042 (ČSN 75 7342)
493 Workplace air Determination of α-modification of silicon dioxide by infrared spectrometry
Regulated area: 4 Organic chemistry
SOP OV 300 (NIOSH 7602; AHEM 8/76; AHEM 2/88)
494 Foods, cosmetic products, bottled water Determination of additives by liquid chromatography (LC/DAD)
acesulfame saccharin aspartame caffeine sorbic acid benzoic acid p-hydroxybenzoic acid 2-phenoxyethanol 1-phenoxy-2-propanol methyl, ethyl, propyl, butyl, isobutyl and benzyl esters of hydroxybenzoic acid (parabens)
Regulated area: 4 Organic chemistry
SOP OV 301 (ČSN EN 12856)
495 Water, bottled water, extracts Determination of acrylamide by gas chromatography (GC/ECD/MS)
Regulated area: 4 Organic chemistry
SOP OV 303 (EPA Method 8032A)
496 Foods Determination of acrylamide by gas chromatography (GC/MS)
Regulated area: 4 Organic chemistry
SOP OV 303.01 (ČSN P CEN/TS 17083)
497 Indoor, outdoor and workplace air, emissions Determination of aldehydes and ketones by liquid chromatography (LC/DAD)
formaldehyde acetaldehyde acetone acrolein propionaldehyde crotonaldehyde butyraldehyde benzaldehyde valeraldehyde m-tolualdehyde hexaldehyde methyl ethyl ketone methacrolein
Regulated area: 4 Organic chemistry
SOP OV 304.01 (EPA Method TO-11A)
498 Fish and fish products Determination of histamine by liquid chromatography (LC/DAD)
Regulated area: 4 Organic chemistry
SOP OV 381 (Journal of Chromatography A, 1032, 2004, 79-85)
499 Urine Determination of metabolites of organic compounds by liquid chromatography (LC/DAD/FLD)
methylhippuric acids (o, m and p) furoic (pyromucic) acid PAH metabolites (1-hydroxypyrene)
Regulated area: 4 Organic chemistry
SOP OV 323
500 Spirits Determination of methanol and volatile organic compounds by gas chromatography (GC/FID/MS)
methanol 2-propanol (isopropanol)
Regulated area: 4 Organic chemistry
SOP OV 324 (ČSN 660805)
501 Water, bottled water, extracts Determination of NEL (non-polar extractives) and EL (extractives) by infrared spectrometry
NEL (non-polar extractives) EL (extractives)
Regulated area: 4 Organic chemistry
SOP OV 309.01 (ČSN 75 7505:1998; ČSN 75 7506)
502 Waste, solid samples Determination of NEL (non-polar extractives) and EL (extractives) by infrared spectrometry
NEL (non-polar extractives) EL (extractives)
Regulated area: 4 Organic chemistry
SOP OV 309.04 (ČSN 75 7505:1998; ČSN 75 7506)
503 Indoor, outdoor and workplace air, compressed gases Determination of NEL (non-polar extractives) and EL (extractives) by infrared spectrometry
NEL (non-polar extractives) EL (extractives)
Regulated area: 4 Organic chemistry
SOP OV 309.07 (ČSN 75 7505:1998; ČSN 75 7506)
504 Water, bottled water, extracts Determination of organochlorinated pesticides (OCP) by gas chromatography (GC/ECD) and the sum of OCP by calculation from measured values
α-HCH β-HCH γ-HCH (lindane) δ-HCH HCB (hexachlorobenzene) aldrin dieldrin endrin heptachlor trans-chlordane cis-chlordane nonachlor methoxychlor o,p′-DDT p,p′-DDT o,p′-DDD p,p′-DDD o,p′-DDE p,p′-DDE endosulfan I (α) and II (β) trans-heptachlor epoxide cis-heptachlor epoxide isodrin trifluralin pentachlorobenzene
sum of OCP (calculated)
Regulated area: 4 Organic chemistry
SOP OV 327 (ČSN EN ISO 6468)
505 Waste, solid samples Determination of organochlorinated pesticides (OCP) by gas chromatography (GC/ECD) and the sum of OCP by calculation from measured values
α-HCH β-HCH γ-HCH (lindane) δ-HCH HCB (hexachlorobenzene) o,p′-DDT p,p′-DDT o,p′-DDD p,p′-DDD o,p′-DDE p,p′-DDE
sum of OCP (calculated)
Regulated area: 4 Organic chemistry
SOP OV 327.01 (EPA Method 8081)
506 Water, bottled water, extracts Determination of pentachlorophenol by gas chromatography (GC/MS)
Regulated area: 4 Organic chemistry
SOP OV 327.14 (ČSN EN 12673)
507 Water, bottled water, extracts Determination of polyaromatic hydrocarbons (PAH) by liquid chromatography (LC/FLD/DAD) and the sum of PAH by calculation from measured values
acenaphthene acenaphthylene anthracene benzo(a)anthracene benzo(a)pyrene benzo(b)fluoranthene benzo(ghi)perylene benzo(k)fluoranthene dibenzo(ah)anthracene phenanthrene fluoranthene fluorene chrysene indeno(1,2,3-cd)pyrene naphthalene pyrene
sum of PAH (calculated)
Regulated area: 4 Organic chemistry
SOP OV 331 (ČSN EN ISO 17993)
508 Waste, solid samples Determination of polyaromatic hydrocarbons (PAH) by liquid chromatography (LC/FLD/DAD) and the sum of PAH by calculation from measured values
acenaphthene acenaphthylene anthracene benzo(a)anthracene benzo(a)pyrene benzo(b)fluoranthene benzo(ghi)perylene benzo(k)fluoranthene dibenzo(ah)anthracene phenanthrene fluoranthene fluorene chrysene indeno(1,2,3-cd)pyrene naphthalene pyrene
sum of PAH (calculated)
Regulated area: 4 Organic chemistry
SOP OV 331.05 (ČSN EN 17503)
509 Indoor, outdoor and workplace air, emissions Determination of polyaromatic hydrocarbons (PAH) by liquid chromatography (LC/FLD/DAD) and the sum of PAH by calculation from measured values
acenaphthene acenaphthylene anthracene benzo(a)anthracene benzo(a)pyrene benzo(b)fluoranthene benzo(ghi)perylene benzo(k)fluoranthene dibenzo(ah)anthracene phenanthrene fluoranthene fluorene chrysene indeno(1,2,3-cd)pyrene naphthalene pyrene benzo(j)fluoranthene
sum of PAH (calculated)
Regulated area: 4 Organic chemistry
SOP OV 331.02 (EPA TO 13; ČSN EN 15549)
510 Foods, edible fats and oils Determination of polyaromatic hydrocarbons (PAH) by liquid chromatography (LC/FLD/DAD) and the sum of PAH by calculation from measured values
anthracene benzo(a)anthracene benzo(a)pyrene benzo(b)fluoranthene benzo(ghi)perylene benzo(k)fluoranthene dibenzo(ah)anthracene phenanthrene fluoranthene chrysene indeno(1,2,3-cd)pyrene pyrene
sum of PAH (calculated)
Regulated area: 4 Organic chemistry
SOP OV 331.06 (ČSN EN ISO 15753)
511 Water, bottled water, extracts Determination of polychlorinated biphenyls (PCB) by gas chromatography (GC/ECD/MS) and the sum of PCB by calculation from measured values
PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180
sum of PCB (calculated)
Regulated area: 4 Organic chemistry
SOP OV 333 (ČSN EN ISO 6468)
512 Waste, solid samples, mineral oils, materials Determination of polychlorinated biphenyls (PCB) by gas chromatography (GC/ECD) and the sum of PCB by calculation from measured values
PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180
sum of PCB (calculated)
Regulated area: 4 Organic chemistry
SOP OV 333.06 (ČSN EN 12766-1; ČSN EN ISO 18475)
513 Foods Determination of saccharides by liquid chromatography (LC/RID)
sorbitol mannitol inulin fructose glucose sucrose maltose and lactose
Regulated area: 4 Organic chemistry
SOP OV 335 (ČSN EN 15086)
514 Foods Determination of synthetic food dyes by liquid chromatography (LC/DAD)
E 102 – tartrazine E 104 – quinoline yellow E 110 – sunset yellow FCF E 122 – azorubine E 123 – amaranth E 124 – Ponceau 4R E 127 – erythrosine E 131 – patent blue E 132 – indigotine E 133 – brilliant blue FCF E 151 – brilliant black BN E 129 – Allura Red AC
Regulated area: 4 Organic chemistry
SOP OV 343.02
515 Water, bottled water, extracts Determination of volatile organic compounds (VOC) by gas chromatography (GC/MS/FID/ECD) and the sum of VOC by calculation from measured values
sum of VOC (calculated)
Regulated area: 4 Organic chemistry
SOP OV 344 (ČSN EN ISO 15680)
516 Waste, solid samples Determination of volatile organic compounds (VOC) by gas chromatography (GC/MS) and the sum of VOC by calculation from measured values
sum of VOC (calculated)
Regulated area: 4 Organic chemistry
SOP OV 344.01 (ČSN EN ISO 15009)
517 Indoor, outdoor and workplace air, emissions Determination of volatile organic compounds (VOC) and other organic compounds by gas chromatography on a sorbent (GC/FID/MS/ECD) and the sum of VOC by calculation from measured values
sum of VOC (calculated)
Regulated area: 4 Organic chemistry
SOP OV 344.12 (ČSN P CEN/TS 13649; ČSN EN 14662-2)
518 Water, bottled water Determination of hydrocarbons C10 to C40 by gas chromatography (GC/FID)
Regulated area: 4 Organic chemistry
SOP OV 338 (ČSN EN ISO 9377-2)
519 Waste, solid samples Determination of hydrocarbons C10 to C40 by gas chromatography (GC/FID)
Regulated area: 4 Organic chemistry
SOP OV 338.01 (ČSN EN 14039)
520 Foods Determination of vitamins by liquid chromatography (LC/DAD/FLUD)
vitamin C vitamins B1, B2, B3, B5 and B6 vitamins A, E
Regulated area: 4 Organic chemistry
SOP OV 340
521 Materials Identification of materials and chemical substances by infrared spectrometry
Regulated area: 4 Organic chemistry
SOP OV 357 (Aplikační list NICOLET)
522 Drinking and bathing water Determination of haloacetic acids by gas chromatography (GC/ECD/MS) and their sum by calculation from measured values
bromoacetic acid dibromoacetic acid dichloroacetic acid chloroacetic acid trichloroacetic acid
sum (calculated)
Regulated area: 4 Organic chemistry
SOP OV 383 (EPA 552.3)
523 Water Determination of alkylphenols by gas chromatography (GC/MS)
nonylphenol 4-tert-octylphenol 4-n-nonylphenol
Regulated area: 4 Organic chemistry
SOP OV 327.12 (ČSN EN ISO 18857-1)
524 Indoor, outdoor and workplace air, compressed gases Measurement of concentration of gaseous pollutants – electrochemical method
sulphur dioxide (SO2) hydrogen sulphide (H2S) carbon monoxide (CO) nitric oxide (NO) nitrogen dioxide (NO2) oxygen (O2) ammonia (NH3)
Regulated area: 5 Air
SOP OV 438
525 Indoor, outdoor and workplace air, compressed gases Determination of carbon monoxide (CO) and carbon dioxide (CO2) with an infrared spectrometry analyzer
carbon monoxide (CO) carbon dioxide (CO2)
Regulated area: 5 Air
SOP OV 438.07
526 Indoor and workplace air Determination of vapours and gases by calculation from specified values
Regulated area: 5 Air
SOP OV 486 (Nařízení vlády č. 361/2007 Sb.; Vyhláška 43/2025 Sb.)
527 Working and non-working environment Measurement and calculation of noise
Regulated area: 6 Physical factors
Měření SOP OV 456, část 1; Výpočet SOP OV 456, část 2
528 Indoor spaces Measurement of reverberation time
Regulated area: 6 Physical factors
SOP OV 464 (ČSN EN ISO 3382-2; ČSN EN ISO 3382-1)
529 Building structures Measurement of airborne sound insulation
Regulated area: 6 Physical factors
SOP OV 468
530 Building structures Measurement of impact sound insulation
Regulated area: 6 Physical factors
SOP OV 468.02
531 Working and non-working environment Measurement of vibration
Regulated area: 6 Physical factors
SOP OV 471
532 Working and non-working environment, roads Measurement of electrical lighting
Regulated area: 6 Physical factors
SOP OV 469
533 Working and non-working environment Measurement of daylight
Regulated area: 6 Physical factors
SOP OV 470
534 Working and non-working environment, cleanrooms and clean zones Measurement of microclimatic conditions
globe temperature air temperature relative air humidity air velocity
operative temperature (calculated)
Regulated area: 6 Physical factors
SOP OV 474
535 Drinking and hot water Sampling of drinking water
Regulated area: Sampling
SOP VZ OV 001 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
536 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP VZ OV 002 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; ČSN 75 7717; Vyhláška č. 238/2011 Sb.)
537 Ground water Sampling of ground water – manual sampling and sampling by pumping
Regulated area: Sampling
SOP VZ OV 003 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)
538 Surface water Sampling from reservoirs, rivers and streams
Regulated area: Sampling
SOP VZ OV 005 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
539 Waste water Sampling of waste water – manual sampling and sampling with an automatic sampler
Regulated area: Sampling
SOP VZ OV 006 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
540 Purified water Sampling of purified water
Regulated area: Sampling
SOP VZ OV 008 (Vyhláška č. 84/2008 Sb.)
541 Outdoor and indoor air, compressed gases Sampling of outdoor and indoor air and compressed gases on a solid sorbent (filter, filter and PUF, sorption tube)
Regulated area: Sampling
SOP VZ OV 109 (Zákon o ochraně ovzduší 201/2012 Sb.; ČSN EN 12341; ČSN EN ISO 16000-7; Vyhláška č. 330/2012 Sb.)
542 Workplace air Sampling of workplace air on a solid sorbent (filter, filter and PUF, filter and sorbent, sorption tube)
Regulated area: Sampling
SOP VZ OV 110 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007Sb.)
543 Workplace air Sampling of workplace air into liquid (fritted absorbers with absorption solution)
Regulated area: Sampling
SOP VZ OV 110.01 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007 Sb.)
544 Workplace air Sampling of workplace air into canisters
Regulated area: Sampling
SOP VZ OV 110.02 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007 Sb.)
545 Waste (solid and liquid waste, biodegradable waste) Sampling of waste
Regulated area: Sampling
SOP VZ OV 201 (ČSN EN 14899; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5)
546 Solid samples (soils, sands, sediments, sludges) Sampling of solid samples
Regulated area: Sampling
SOP VZ OV 218 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN 01 5110; ČSN 01 5111; ČSN 01 5112)
547 Surfaces, skin Sampling from surfaces of objects for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 206 (ČSN EN ISO 18593)
548 Sterilizers Sampling with biological and non-biological systems for verification of sterilizer efficiency
Regulated area: Sampling
SOP VZ OV 213 (AHEM 1/2014)
Bruntál
549 Surface and bathing water Preliminary sensory analysis
appearance (algal bloom, waste pollution, natural pollution) transparency
Regulated area: 1 Basic chemistry
SOP OV 062.01 (ČSN 75 7340)
550 Water, purified water Determination of total and free chlorine by spectrophotometry by HACH set and bound chlorine by calculation from measured values
total chlorine free chlorine
bound chlorine (calculated)
Regulated area: 1 Basic chemistry
SOP OV 008.01 (návod firmy HACH)
551 Drinking, ground, bathing and purified water, waste and process water Determination of chlorine dioxide by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 018.01 (návod firmy HACH/MERCK)
552 Water, purified water Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042 (ČSN 75 7342)
553 Drinking and hot water Sampling of drinking water
Regulated area: Sampling
SOP VZ OV 001 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
554 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP VZ OV 002 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; ČSN 75 7717; Vyhláška č. 238/2011 Sb.)
555 Ground water Sampling of ground water – manual sampling and sampling by pumping
Regulated area: Sampling
SOP VZ OV 003 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)
556 Waste water Sampling of waste water – manual sampling and sampling with an automatic sampler
Regulated area: Sampling
SOP VZ OV 006 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
557 Waste (solid and liquid waste, biodegradable waste) Sampling of waste
Regulated area: Sampling
SOP VZ OV 201 (ČSN EN 14899; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5)
558 Solid samples (soils, sands, sediments, sludges) Sampling of solid samples
Regulated area: Sampling
SOP VZ OV 218 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN 01 5110; ČSN 01 5111; ČSN 01 5112)
559 Surfaces, skin Sampling from surfaces of objects for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 206 (ČSN EN ISO 18593)
560 Sterilizers Sampling with biological and non-biological systems for verification of sterilizer efficiency
Regulated area: Sampling
SOP VZ OV 213 (AHEM 1/2014)
Zlín
561 Surface and bathing water Preliminary sensory analysis
appearance (algal bloom, waste pollution, natural pollution) transparency
Regulated area: 1 Basic chemistry
SOP OV 062.01 (ČSN 75 7340)
562 Water, purified water Determination of total and free chlorine by spectrophotometry by HACH set and bound chlorine by calculation from measured values
total chlorine free chlorine
bound chlorine (calculated)
Regulated area: 1 Basic chemistry
SOP OV 008.01 (návod firmy HACH)
563 Water Determination of pH by potentiometry
Regulated area: 1 Basic chemistry
SOP OV 033.02 (ČSN ISO 10523)
564 Drinking, ground, bathing and purified water, waste and process water Determination of chlorine dioxide by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 018.01 (návod firmy HACH/MERCK)
565 Drinking, bathing, ground and surface water Determination of redox potential
Regulated area: 1 Basic chemistry
SOP OV 028 (ČSN 75 7367)
566 Bathing water, drinking water Determination of ozone by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 032.02 (návod firmy HACH/MERCK)
567 Water, purified water Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042 (ČSN 75 7342)
568 Workplace air Preliminary determination of gases and vapours by detection tubes
ammonia (NH3) chlorine (Cl2) nitrogen dioxide (NO2) nitric oxide (NO) hydrogen sulphide (H2S) sulphur dioxide (SO2) hydrogen cyanide (HCN) carbon dioxide (CO2) ozone (O3) carbon monoxide (CO) carbon disulphide (CS2) phenol nitrous gases (NOx) hydrogen (H2) hydrogen peroxide (H2O2)
Regulated area: 5 Air
SOP OV 424 (manuály firmy GASTEC a Dräger)
569 Indoor, outdoor and workplace air, compressed gases Measurement of concentration of gaseous pollutants – electrochemical method
sulphur dioxide (SO2) hydrogen sulphide (H2S) carbon monoxide (CO) nitric oxide (NO) nitrogen dioxide (NO2) oxygen (O2) ammonia (NH3)
Regulated area: 5 Air
SOP OV 438
570 Indoor, outdoor and workplace air, compressed gases Determination of carbon monoxide (CO) and carbon dioxide (CO2) with an infrared spectrometry analyzer
carbon monoxide (CO) carbon dioxide (CO2)
Regulated area: 5 Air
SOP OV 438.07
571 Indoor and workplace air Determination of vapours and gases by calculation from specified values
Regulated area: 5 Air
SOP OV 486 (Nařízení vlády č. 361/2007 Sb.; Vyhláška 43/2025 Sb.)
572 Working and non-working environment Measurement and calculation of noise
Regulated area: 6 Physical factors
Měření SOP OV 456, část 1; Výpočet SOP OV 456, část 2
573 Working and non-working environment Measurement of vibration
Regulated area: 6 Physical factors
SOP OV 471
574 Working and non-working environment, roads Measurement of electrical lighting
Regulated area: 6 Physical factors
SOP OV 469
575 Working and non-working environment Measurement of daylight
Regulated area: 6 Physical factors
SOP OV 470
576 Working and non-working environment, cleanrooms and clean zones Measurement of microclimatic conditions
globe temperature air temperature relative air humidity air velocity
operative temperature (calculated)
Regulated area: 6 Physical factors
SOP OV 474
577 Working and non-working environment Measurement of electromagnetic field
Regulated area: 6 Physical factors
SOP OV 452
578 Drinking and hot water Sampling of drinking water
Regulated area: Sampling
SOP VZ OV 001 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
579 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP VZ OV 002 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; ČSN 75 7717; Vyhláška č. 238/2011 Sb.)
580 Ground water Sampling of ground water – manual sampling and sampling by pumping
Regulated area: Sampling
SOP VZ OV 003 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)
581 Surface water Sampling from reservoirs, rivers and streams
Regulated area: Sampling
SOP VZ OV 005 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
582 Waste water Sampling of waste water – manual sampling and sampling with an automatic sampler
Regulated area: Sampling
SOP VZ OV 006 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
583 Purified water Sampling of purified water
Regulated area: Sampling
SOP VZ OV 008 (Vyhláška č. 84/2008 Sb.)
584 Outdoor and indoor air, compressed gases Sampling of outdoor and indoor air and compressed gases on a solid sorbent (filter, filter and PUF, sorption tube)
Regulated area: Sampling
SOP VZ OV 109 (Zákon o ochraně ovzduší 201/2012 Sb.; ČSN EN 12341; ČSN EN ISO 16000-7; Vyhláška č. 330/2012 Sb.)
585 Outdoor and indoor air Sampling of outdoor and indoor air into liquid (sorption solution, sedimentation vessel)
Regulated area: Sampling
SOP VZ OV 109.01 (Zákon o ochraně ovzduší 201/2012 Sb.)
586 Outdoor and indoor air Sampling of outdoor and indoor air onto culture media
Regulated area: Sampling
SOP VZ OV 109.03 (AHEM 1/2002; AHEM 4/2021)
587 Workplace air Sampling of workplace air on a solid sorbent (filter, filter and PUF, filter and sorbent, sorption tube)
Regulated area: Sampling
SOP VZ OV 110 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007Sb.)
588 Workplace air Sampling of workplace air into liquid (fritted absorbers with absorption solution)
Regulated area: Sampling
SOP VZ OV 110.01 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007 Sb.)
589 Workplace air Sampling of workplace air into canisters
Regulated area: Sampling
SOP VZ OV 110.02 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007 Sb.)
590 Waste (solid and liquid waste, biodegradable waste) Sampling of waste
Regulated area: Sampling
SOP VZ OV 201 (ČSN EN 14899; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5)
591 Sand Sampling of sand from sandpits and outdoor playgrounds
Regulated area: Sampling
SOP VZ OV 204 (Pokyn hlavního hygienika ČR k zajištění jednotného postupu při kontrolách pískovišť venkovních hracích ploch, č.j. 3209/2014 ze dne 12.3.2014)
592 Solid samples (soils, sands, sediments, sludges) Sampling of solid samples
Regulated area: Sampling
SOP VZ OV 218 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN 01 5110; ČSN 01 5111; ČSN 01 5112)
593 Surfaces, skin Sampling from surfaces of objects for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 206 (ČSN EN ISO 18593)
594 Sterilizers Sampling with biological and non-biological systems for verification of sterilizer efficiency
Regulated area: Sampling
SOP VZ OV 213 (AHEM 1/2014)
Vsetín
595 Surface and bathing water Preliminary sensory analysis
appearance (algal bloom, waste pollution, natural pollution) transparency
Regulated area: 1 Basic chemistry
SOP OV 062.01 (ČSN 75 7340)
596 Water, purified water Determination of total and free chlorine by spectrophotometry by HACH set and bound chlorine by calculation from measured values
total chlorine free chlorine
bound chlorine (calculated)
Regulated area: 1 Basic chemistry
SOP OV 008.01 (návod firmy HACH)
597 Water Determination of pH by potentiometry
Regulated area: 1 Basic chemistry
SOP OV 033.02 (ČSN ISO 10523)
598 Drinking, ground, bathing and purified water, waste and process water Determination of chlorine dioxide by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 018.01 (návod firmy HACH/MERCK)
599 Drinking, bathing, ground and surface water Determination of redox potential
Regulated area: 1 Basic chemistry
SOP OV 028 (ČSN 75 7367)
600 Bathing water, drinking water Determination of ozone by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 032.02 (návod firmy HACH/MERCK)
601 Water, purified water Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042 (ČSN 75 7342)
602 Workplace air Preliminary determination of gases and vapours by detection tubes
ammonia (NH3) chlorine (Cl2) nitrogen dioxide (NO2) nitric oxide (NO) hydrogen sulphide (H2S) sulphur dioxide (SO2) hydrogen cyanide (HCN) carbon dioxide (CO2) ozone (O3) carbon monoxide (CO) carbon disulphide (CS2) phenol nitrous gases (NOx) hydrogen (H2) hydrogen peroxide (H2O2)
Regulated area: 5 Air
SOP OV 424 (manuály firmy GASTEC a Dräger)
603 Indoor and workplace air Determination of vapours and gases by calculation from specified values
Regulated area: 5 Air
SOP OV 486 (Nařízení vlády č. 361/2007 Sb.; Vyhláška 43/2025 Sb.)
604 Working and non-working environment Measurement and calculation of noise
Regulated area: 6 Physical factors
Měření SOP OV 456, část 1; Výpočet SOP OV 456, část 2
605 Working and non-working environment, roads Measurement of electrical lighting
Regulated area: 6 Physical factors
SOP OV 469
606 Working and non-working environment Measurement of daylight
Regulated area: 6 Physical factors
SOP OV 470
607 Working and non-working environment, cleanrooms and clean zones Measurement of microclimatic conditions
globe temperature air temperature relative air humidity air velocity
operative temperature (calculated)
Regulated area: 6 Physical factors
SOP OV 474
608 Drinking and hot water Sampling of drinking water
Regulated area: Sampling
SOP VZ OV 001 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
609 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP VZ OV 002 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; ČSN 75 7717; Vyhláška č. 238/2011 Sb.)
610 Ground water Sampling of ground water – manual sampling and sampling by pumping
Regulated area: Sampling
SOP VZ OV 003 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)
611 Surface water Sampling from reservoirs, rivers and streams
Regulated area: Sampling
SOP VZ OV 005 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
612 Waste water Sampling of waste water – manual sampling and sampling with an automatic sampler
Regulated area: Sampling
SOP VZ OV 006 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
613 Purified water Sampling of purified water
Regulated area: Sampling
SOP VZ OV 008 (Vyhláška č. 84/2008 Sb.)
614 Workplace air Sampling of workplace air on a solid sorbent (filter, filter and PUF, filter and sorbent, sorption tube)
Regulated area: Sampling
SOP VZ OV 110 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007Sb.)
615 Waste (solid and liquid waste, biodegradable waste) Sampling of waste
Regulated area: Sampling
SOP VZ OV 201 (ČSN EN 14899; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5)
616 Sand Sampling of sand from sandpits and outdoor playgrounds
Regulated area: Sampling
SOP VZ OV 204 (Pokyn hlavního hygienika ČR k zajištění jednotného postupu při kontrolách pískovišť venkovních hracích ploch, č.j. 3209/2014 ze dne 12.3.2014)
617 Solid samples (soils, sands, sediments, sludges) Sampling of solid samples
Regulated area: Sampling
SOP VZ OV 218 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN 01 5110; ČSN 01 5111; ČSN 01 5112)
618 Surfaces, skin Sampling from surfaces of objects for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 206 (ČSN EN ISO 18593)
619 Sterilizers Sampling with biological and non-biological systems for verification of sterilizer efficiency
Regulated area: Sampling
SOP VZ OV 213 (AHEM 1/2014)
Šumperk
620 Surface and bathing water Preliminary sensory analysis
appearance (algal bloom, waste pollution, natural pollution) transparency
Regulated area: 1 Basic chemistry
SOP OV 062.01 (ČSN 75 7340)
621 Water, purified water Determination of total and free chlorine by spectrophotometry by HACH set and bound chlorine by calculation from measured values
total chlorine free chlorine
bound chlorine (calculated)
Regulated area: 1 Basic chemistry
SOP OV 008.01 (návod firmy HACH)
622 Drinking, ground, bathing and purified water, waste and process water Determination of chlorine dioxide by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 018.01 (návod firmy HACH/MERCK)
623 Bathing water, drinking water Determination of ozone by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 032.02 (návod firmy HACH/MERCK)
624 Water, purified water Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042 (ČSN 75 7342)
625 Workplace air Preliminary determination of gases and vapours by detection tubes
ammonia (NH3) chlorine (Cl2) nitrogen dioxide (NO2) nitric oxide (NO) hydrogen sulphide (H2S) sulphur dioxide (SO2) hydrogen cyanide (HCN) carbon dioxide (CO2) ozone (O3) carbon monoxide (CO) carbon disulphide (CS2) phenol nitrous gases (NOx) hydrogen (H2) hydrogen peroxide (H2O2)
Regulated area: 5 Air
SOP OV 424 (manuály firmy GASTEC a Dräger)
626 Indoor, outdoor and workplace air, compressed gases Measurement of concentration of gaseous pollutants – electrochemical method
sulphur dioxide (SO2) hydrogen sulphide (H2S) carbon monoxide (CO) nitric oxide (NO) nitrogen dioxide (NO2) oxygen (O2) ammonia (NH3)
Regulated area: 5 Air
SOP OV 438
627 Indoor, outdoor and workplace air, compressed gases Determination of carbon monoxide (CO) and carbon dioxide (CO2) with an infrared spectrometry analyzer
carbon monoxide (CO) carbon dioxide (CO2)
Regulated area: 5 Air
SOP OV 438.07
628 Indoor and workplace air Determination of vapours and gases by calculation from specified values
Regulated area: 5 Air
SOP OV 486 (Nařízení vlády č. 361/2007 Sb.; Vyhláška 43/2025 Sb.)
629 Working and non-working environment Measurement and calculation of noise
Regulated area: 6 Physical factors
Měření SOP OV 456, část 1; Výpočet SOP OV 456, část 2
630 Working and non-working environment Measurement of vibration
Regulated area: 6 Physical factors
SOP OV 471
631 Working and non-working environment, roads Measurement of electrical lighting
Regulated area: 6 Physical factors
SOP OV 469
632 Working and non-working environment Measurement of daylight
Regulated area: 6 Physical factors
SOP OV 470
633 Working and non-working environment, cleanrooms and clean zones Measurement of microclimatic conditions
globe temperature air temperature relative air humidity air velocity
operative temperature (calculated)
Regulated area: 6 Physical factors
SOP OV 474
634 Drinking and hot water Sampling of drinking water
Regulated area: Sampling
SOP VZ OV 001 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
635 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP VZ OV 002 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; ČSN 75 7717; Vyhláška č. 238/2011 Sb.)
636 Ground water Sampling of ground water – manual sampling and sampling by pumping
Regulated area: Sampling
SOP VZ OV 003 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)
637 Surface water Sampling from reservoirs, rivers and streams
Regulated area: Sampling
SOP VZ OV 005 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
638 Waste water Sampling of waste water – manual sampling and sampling with an automatic sampler
Regulated area: Sampling
SOP VZ OV 006 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
639 Outdoor and indoor air, compressed gases Sampling of outdoor and indoor air and compressed gases on a solid sorbent (filter, filter and PUF, sorption tube)
Regulated area: Sampling
SOP VZ OV 109 (Zákon o ochraně ovzduší 201/2012 Sb.; ČSN EN 12341; ČSN EN ISO 16000-7; Vyhláška č. 330/2012 Sb.)
640 Outdoor and indoor air Sampling of outdoor and indoor air into liquid (sorption solution, sedimentation vessel)
Regulated area: Sampling
SOP VZ OV 109.01 (Zákon o ochraně ovzduší 201/2012 Sb.)
641 Outdoor and indoor air Sampling of outdoor and indoor air onto culture media
Regulated area: Sampling
SOP VZ OV 109.03 (AHEM 1/2002; AHEM 4/2021)
642 Workplace air Sampling of workplace air on a solid sorbent (filter, filter and PUF, filter and sorbent, sorption tube)
Regulated area: Sampling
SOP VZ OV 110 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007Sb.)
643 Workplace air Sampling of workplace air into liquid (fritted absorbers with absorption solution)
Regulated area: Sampling
SOP VZ OV 110.01 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007 Sb.)
644 Workplace air Sampling of workplace air into canisters
Regulated area: Sampling
SOP VZ OV 110.02 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007 Sb.)
645 Waste (solid and liquid waste, biodegradable waste) Sampling of waste
Regulated area: Sampling
SOP VZ OV 201 (ČSN EN 14899; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5)
646 Sand Sampling of sand from sandpits and outdoor playgrounds
Regulated area: Sampling
SOP VZ OV 204 (Pokyn hlavního hygienika ČR k zajištění jednotného postupu při kontrolách pískovišť venkovních hracích ploch, č.j. 3209/2014 ze dne 12.3.2014)
647 Solid samples (soils, sands, sediments, sludges) Sampling of solid samples
Regulated area: Sampling
SOP VZ OV 218 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN 01 5110; ČSN 01 5111; ČSN 01 5112)
648 Foods Sampling of foods for microbiological testing
Regulated area: Sampling
SOP VZ OV 200 (ČSN P CEN ISO/TS 17728)
649 Surfaces, skin Sampling from surfaces of objects for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 206 (ČSN EN ISO 18593)
650 Sterilizers Sampling with biological and non-biological systems for verification of sterilizer efficiency
Regulated area: Sampling
SOP VZ OV 213 (AHEM 1/2014)
651 Surfaces, sterile and non-sterile products, skin Sampling and swabbing for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 214 (AHEM 7/1992)
Havlíčkův Brod
652 Surface and bathing water Preliminary sensory analysis
appearance (algal bloom, waste pollution, natural pollution) transparency
Regulated area: 1 Basic chemistry
SOP OV 062.01 (ČSN 75 7340)
653 Drinking, ground, surface, bathing, waste and process water Determination of dissolved oxygen, method with optical sensor
Regulated area: 1 Basic chemistry
SOP OV 036.01 (ČSN ISO 17289; návod firmy WTW)
654 Water, purified water Determination of total and free chlorine by spectrophotometry by HACH set and bound chlorine by calculation from measured values
total chlorine free chlorine
bound chlorine (calculated)
Regulated area: 1 Basic chemistry
SOP OV 008.01 (návod firmy HACH)
655 Drinking, ground, bathing and purified water, waste and process water Determination of chlorine dioxide by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 018.01 (návod firmy HACH/MERCK)
656 Drinking, bathing, ground and surface water Determination of redox potential
Regulated area: 1 Basic chemistry
SOP OV 028 (ČSN 75 7367)
657 Bathing water, drinking water Determination of ozone by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 032.02 (návod firmy HACH/MERCK)
658 Water, purified water Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042 (ČSN 75 7342)
659 Foods Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042.01 (ČSN EN 13485)
660 Working and non-working environment Measurement and calculation of noise
Regulated area: 6 Physical factors
Měření SOP OV 456, část 1; Výpočet SOP OV 456, část 2
661 Indoor spaces Measurement of reverberation time
Regulated area: 6 Physical factors
SOP OV 464 (ČSN EN ISO 3382-2; ČSN EN ISO 3382-1)
662 Working and non-working environment Measurement of vibration
Regulated area: 6 Physical factors
SOP OV 471
663 Working and non-working environment, roads Measurement of electrical lighting
Regulated area: 6 Physical factors
SOP OV 469
664 Working and non-working environment Measurement of daylight
Regulated area: 6 Physical factors
SOP OV 470
665 Drinking and hot water Sampling of drinking water
Regulated area: Sampling
SOP VZ OV 001 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
666 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP VZ OV 002 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; ČSN 75 7717; Vyhláška č. 238/2011 Sb.)
667 Ground water Sampling of ground water – manual sampling and sampling by pumping
Regulated area: Sampling
SOP VZ OV 003 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)
668 Surface water Sampling from reservoirs, rivers and streams
Regulated area: Sampling
SOP VZ OV 005 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
669 Waste water Sampling of waste water – manual sampling and sampling with an automatic sampler
Regulated area: Sampling
SOP VZ OV 006 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
670 Purified water Sampling of purified water
Regulated area: Sampling
SOP VZ OV 008 (Vyhláška č. 84/2008 Sb.)
671 Process water Sampling of process water
Regulated area: Sampling
SOP VZ OV 011 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-7; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
672 Outdoor and indoor air Sampling of outdoor and indoor air onto culture media
Regulated area: Sampling
SOP VZ OV 109.03 (AHEM 1/2002; AHEM 4/2021)
673 Waste (solid and liquid waste, biodegradable waste) Sampling of waste
Regulated area: Sampling
SOP VZ OV 201 (ČSN EN 14899; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5)
674 Sand Sampling of sand from sandpits and outdoor playgrounds
Regulated area: Sampling
SOP VZ OV 204 (Pokyn hlavního hygienika ČR k zajištění jednotného postupu při kontrolách pískovišť venkovních hracích ploch, č.j. 3209/2014 ze dne 12.3.2014)
675 Solid samples (soils, sands, sediments, sludges) Sampling of solid samples
Regulated area: Sampling
SOP VZ OV 218 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN 01 5110; ČSN 01 5111; ČSN 01 5112)
676 Foods Sampling of foods for microbiological testing
Regulated area: Sampling
SOP VZ OV 200 (ČSN P CEN ISO/TS 17728)
677 Surfaces, skin Sampling from surfaces of objects for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 206 (ČSN EN ISO 18593)
678 Sterilizers Sampling with biological and non-biological systems for verification of sterilizer efficiency
Regulated area: Sampling
SOP VZ OV 213 (AHEM 1/2014)
679 Surfaces, sterile and non-sterile products, skin Sampling and swabbing for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 214 (AHEM 7/1992)
Pelhřimov
680 Surface and bathing water Preliminary sensory analysis
appearance (algal bloom, waste pollution, natural pollution) transparency
Regulated area: 1 Basic chemistry
SOP OV 062.01 (ČSN 75 7340)
681 Drinking, ground, surface, bathing, waste and process water Determination of dissolved oxygen, method with optical sensor
Regulated area: 1 Basic chemistry
SOP OV 036.01 (ČSN ISO 17289; návod firmy WTW)
682 Water, purified water Determination of total and free chlorine by spectrophotometry by HACH set and bound chlorine by calculation from measured values
total chlorine free chlorine
bound chlorine (calculated)
Regulated area: 1 Basic chemistry
SOP OV 008.01 (návod firmy HACH)
683 Drinking, bathing, ground and surface water Determination of redox potential
Regulated area: 1 Basic chemistry
SOP OV 028 (ČSN 75 7367)
684 Bathing water, drinking water Determination of ozone by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 032.02 (návod firmy HACH/MERCK)
685 Water, purified water Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042 (ČSN 75 7342)
686 Foods Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042.01 (ČSN EN 13485)
687 Indoor, outdoor and workplace air, compressed gases Determination of carbon monoxide (CO) and carbon dioxide (CO2) with an infrared spectrometry analyzer
carbon monoxide (CO) carbon dioxide (CO2)
Regulated area: 5 Air
SOP OV 438.07
688 Indoor and workplace air Determination of vapours and gases by calculation from specified values
Regulated area: 5 Air
SOP OV 486 (Nařízení vlády č. 361/2007 Sb.; Vyhláška 43/2025 Sb.)
689 Working and non-working environment Measurement and calculation of noise
Regulated area: 6 Physical factors
Měření SOP OV 456, část 1; Výpočet SOP OV 456, část 2
690 Working and non-working environment, roads Measurement of electrical lighting
Regulated area: 6 Physical factors
SOP OV 469
691 Working and non-working environment Measurement of daylight
Regulated area: 6 Physical factors
SOP OV 470
692 Drinking and hot water Sampling of drinking water
Regulated area: Sampling
SOP VZ OV 001 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
693 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP VZ OV 002 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; ČSN 75 7717; Vyhláška č. 238/2011 Sb.)
694 Ground water Sampling of ground water – manual sampling and sampling by pumping
Regulated area: Sampling
SOP VZ OV 003 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)
695 Surface water Sampling from reservoirs, rivers and streams
Regulated area: Sampling
SOP VZ OV 005 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
696 Waste water Sampling of waste water – manual sampling and sampling with an automatic sampler
Regulated area: Sampling
SOP VZ OV 006 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
697 Purified water Sampling of purified water
Regulated area: Sampling
SOP VZ OV 008 (Vyhláška č. 84/2008 Sb.)
698 Process water Sampling of process water
Regulated area: Sampling
SOP VZ OV 011 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-7; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
699 Outdoor and indoor air Sampling of outdoor and indoor air onto culture media
Regulated area: Sampling
SOP VZ OV 109.03 (AHEM 1/2002; AHEM 4/2021)
700 Workplace air Sampling of workplace air on a solid sorbent (filter, filter and PUF, filter and sorbent, sorption tube)
Regulated area: Sampling
SOP VZ OV 110 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007Sb.)
701 Waste (solid and liquid waste, biodegradable waste) Sampling of waste
Regulated area: Sampling
SOP VZ OV 201 (ČSN EN 14899; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5)
702 Sand Sampling of sand from sandpits and outdoor playgrounds
Regulated area: Sampling
SOP VZ OV 204 (Pokyn hlavního hygienika ČR k zajištění jednotného postupu při kontrolách pískovišť venkovních hracích ploch, č.j. 3209/2014 ze dne 12.3.2014)
703 Solid samples (soils, sands, sediments, sludges) Sampling of solid samples
Regulated area: Sampling
SOP VZ OV 218 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN 01 5110; ČSN 01 5111; ČSN 01 5112)
704 Foods Sampling of foods for microbiological testing
Regulated area: Sampling
SOP VZ OV 200 (ČSN P CEN ISO/TS 17728)
705 Surfaces, skin Sampling from surfaces of objects for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 206 (ČSN EN ISO 18593)
706 Sterilizers Sampling with biological and non-biological systems for verification of sterilizer efficiency
Regulated area: Sampling
SOP VZ OV 213 (AHEM 1/2014)
707 Surfaces, sterile and non-sterile products, skin Sampling and swabbing for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 214 (AHEM 7/1992)
Třebíč
708 Surface and bathing water Preliminary sensory analysis
appearance (algal bloom, waste pollution, natural pollution) transparency
Regulated area: 1 Basic chemistry
SOP OV 062.01 (ČSN 75 7340)
709 Drinking, ground, surface, bathing, waste and process water Determination of dissolved oxygen, method with optical sensor
Regulated area: 1 Basic chemistry
SOP OV 036.01 (ČSN ISO 17289; návod firmy WTW)
710 Water, purified water Determination of total and free chlorine by spectrophotometry by HACH set and bound chlorine by calculation from measured values
total chlorine free chlorine
bound chlorine (calculated)
Regulated area: 1 Basic chemistry
SOP OV 008.01 (návod firmy HACH)
711 Drinking, bathing, ground and surface water Determination of redox potential
Regulated area: 1 Basic chemistry
SOP OV 028 (ČSN 75 7367)
712 Bathing water, drinking water Determination of ozone by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 032.02 (návod firmy HACH/MERCK)
713 Water, purified water Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042 (ČSN 75 7342)
714 Foods Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042.01 (ČSN EN 13485)
715 Drinking and hot water Sampling of drinking water
Regulated area: Sampling
SOP VZ OV 001 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
716 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP VZ OV 002 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; ČSN 75 7717; Vyhláška č. 238/2011 Sb.)
717 Ground water Sampling of ground water – manual sampling and sampling by pumping
Regulated area: Sampling
SOP VZ OV 003 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)
718 Surface water Sampling from reservoirs, rivers and streams
Regulated area: Sampling
SOP VZ OV 005 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
719 Waste water Sampling of waste water – manual sampling and sampling with an automatic sampler
Regulated area: Sampling
SOP VZ OV 006 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
720 Purified water Sampling of purified water
Regulated area: Sampling
SOP VZ OV 008 (Vyhláška č. 84/2008 Sb.)
721 Process water Sampling of process water
Regulated area: Sampling
SOP VZ OV 011 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-7; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
722 Outdoor and indoor air Sampling of outdoor and indoor air onto culture media
Regulated area: Sampling
SOP VZ OV 109.03 (AHEM 1/2002; AHEM 4/2021)
723 Waste (solid and liquid waste, biodegradable waste) Sampling of waste
Regulated area: Sampling
SOP VZ OV 201 (ČSN EN 14899; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5)
724 Sand Sampling of sand from sandpits and outdoor playgrounds
Regulated area: Sampling
SOP VZ OV 204 (Pokyn hlavního hygienika ČR k zajištění jednotného postupu při kontrolách pískovišť venkovních hracích ploch, č.j. 3209/2014 ze dne 12.3.2014)
725 Solid samples (soils, sands, sediments, sludges) Sampling of solid samples
Regulated area: Sampling
SOP VZ OV 218 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN 01 5110; ČSN 01 5111; ČSN 01 5112)
726 Foods Sampling of foods for microbiological testing
Regulated area: Sampling
SOP VZ OV 200 (ČSN P CEN ISO/TS 17728)
727 Surfaces, skin Sampling from surfaces of objects for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 206 (ČSN EN ISO 18593)
728 Sterilizers Sampling with biological and non-biological systems for verification of sterilizer efficiency
Regulated area: Sampling
SOP VZ OV 213 (AHEM 1/2014)
729 Surfaces, sterile and non-sterile products, skin Sampling and swabbing for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 214 (AHEM 7/1992)
Žďár nad Sázavou
730 Surface and bathing water Preliminary sensory analysis
appearance (algal bloom, waste pollution, natural pollution) transparency
Regulated area: 1 Basic chemistry
SOP OV 062.01 (ČSN 75 7340)
731 Drinking, ground, surface, bathing, waste and process water Determination of dissolved oxygen, method with optical sensor
Regulated area: 1 Basic chemistry
SOP OV 036.01 (ČSN ISO 17289; návod firmy WTW)
732 Water, purified water Determination of total and free chlorine by spectrophotometry by HACH set and bound chlorine by calculation from measured values
total chlorine free chlorine
bound chlorine (calculated)
Regulated area: 1 Basic chemistry
SOP OV 008.01 (návod firmy HACH)
733 Drinking, bathing, ground and surface water Determination of redox potential
Regulated area: 1 Basic chemistry
SOP OV 028 (ČSN 75 7367)
734 Bathing water, drinking water Determination of ozone by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 032.02 (návod firmy HACH/MERCK)
735 Water, purified water Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042 (ČSN 75 7342)
736 Foods Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042.01 (ČSN EN 13485)
737 Drinking and hot water Sampling of drinking water
Regulated area: Sampling
SOP VZ OV 001 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
738 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP VZ OV 002 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; ČSN 75 7717; Vyhláška č. 238/2011 Sb.)
739 Ground water Sampling of ground water – manual sampling and sampling by pumping
Regulated area: Sampling
SOP VZ OV 003 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)
740 Surface water Sampling from reservoirs, rivers and streams
Regulated area: Sampling
SOP VZ OV 005 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
741 Waste water Sampling of waste water – manual sampling and sampling with an automatic sampler
Regulated area: Sampling
SOP VZ OV 006 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
742 Purified water Sampling of purified water
Regulated area: Sampling
SOP VZ OV 008 (Vyhláška č. 84/2008 Sb.)
743 Process water Sampling of process water
Regulated area: Sampling
SOP VZ OV 011 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-7; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
744 Outdoor and indoor air Sampling of outdoor and indoor air onto culture media
Regulated area: Sampling
SOP VZ OV 109.03 (AHEM 1/2002; AHEM 4/2021)
745 Waste (solid and liquid waste, biodegradable waste) Sampling of waste
Regulated area: Sampling
SOP VZ OV 201 (ČSN EN 14899; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5)
746 Sand Sampling of sand from sandpits and outdoor playgrounds
Regulated area: Sampling
SOP VZ OV 204 (Pokyn hlavního hygienika ČR k zajištění jednotného postupu při kontrolách pískovišť venkovních hracích ploch, č.j. 3209/2014 ze dne 12.3.2014)
747 Solid samples (soils, sands, sediments, sludges) Sampling of solid samples
Regulated area: Sampling
SOP VZ OV 218 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN 01 5110; ČSN 01 5111; ČSN 01 5112)
748 Foods Sampling of foods for microbiological testing
Regulated area: Sampling
SOP VZ OV 200 (ČSN P CEN ISO/TS 17728)
749 Surfaces, skin Sampling from surfaces of objects for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 206 (ČSN EN ISO 18593)
750 Sterilizers Sampling with biological and non-biological systems for verification of sterilizer efficiency
Regulated area: Sampling
SOP VZ OV 213 (AHEM 1/2014)
751 Surfaces, sterile and non-sterile products, skin Sampling and swabbing for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 214 (AHEM 7/1992)
Frýdek-Místek
752 Surface and bathing water Preliminary sensory analysis
appearance (algal bloom, waste pollution, natural pollution) transparency
Regulated area: 1 Basic chemistry
SOP OV 062.01 (ČSN 75 7340)
753 Water, purified water Determination of total and free chlorine by spectrophotometry by HACH set and bound chlorine by calculation from measured values
total chlorine free chlorine
bound chlorine (calculated)
Regulated area: 1 Basic chemistry
SOP OV 008.01 (návod firmy HACH)
754 Water Determination of pH by potentiometry
Regulated area: 1 Basic chemistry
SOP OV 033.02 (ČSN ISO 10523)
755 Bathing water, drinking water Determination of ozone by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 032.02 (návod firmy HACH/MERCK)
756 Water, purified water Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042 (ČSN 75 7342)
757 Foods Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042.01 (ČSN EN 13485)
758 Drinking and hot water Sampling of drinking water
Regulated area: Sampling
SOP VZ OV 001 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
759 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP VZ OV 002 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; ČSN 75 7717; Vyhláška č. 238/2011 Sb.)
760 Ground water Sampling of ground water – manual sampling and sampling by pumping
Regulated area: Sampling
SOP VZ OV 003 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)
761 Surface water Sampling from reservoirs, rivers and streams
Regulated area: Sampling
SOP VZ OV 005 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
762 Waste water Sampling of waste water – manual sampling and sampling with an automatic sampler
Regulated area: Sampling
SOP VZ OV 006 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
763 Purified water Sampling of purified water
Regulated area: Sampling
SOP VZ OV 008 (Vyhláška č. 84/2008 Sb.)
764 Waste (solid and liquid waste, biodegradable waste) Sampling of waste
Regulated area: Sampling
SOP VZ OV 201 (ČSN EN 14899; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5)
765 Sand Sampling of sand from sandpits and outdoor playgrounds
Regulated area: Sampling
SOP VZ OV 204 (Pokyn hlavního hygienika ČR k zajištění jednotného postupu při kontrolách pískovišť venkovních hracích ploch, č.j. 3209/2014 ze dne 12.3.2014)
766 Solid samples (soils, sands, sediments, sludges) Sampling of solid samples
Regulated area: Sampling
SOP VZ OV 218 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN 01 5110; ČSN 01 5111; ČSN 01 5112)
767 Foods Sampling of foods for microbiological testing
Regulated area: Sampling
SOP VZ OV 200 (ČSN P CEN ISO/TS 17728)
768 Surfaces, skin Sampling from surfaces of objects for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 206 (ČSN EN ISO 18593)
769 Sterilizers Sampling with biological and non-biological systems for verification of sterilizer efficiency
Regulated area: Sampling
SOP VZ OV 213 (AHEM 1/2014)
Opava
770 Surface and bathing water Preliminary sensory analysis
appearance (algal bloom, waste pollution, natural pollution) transparency
Regulated area: 1 Basic chemistry
SOP OV 062.01 (ČSN 75 7340)
771 Water, purified water Determination of total and free chlorine by spectrophotometry by HACH set and bound chlorine by calculation from measured values
total chlorine free chlorine
bound chlorine (calculated)
Regulated area: 1 Basic chemistry
SOP OV 008.01 (návod firmy HACH)
772 Drinking, ground, bathing and purified water, waste and process water Determination of chlorine dioxide by spectrophotometry with HACH/MERCK set
Regulated area: 1 Basic chemistry
SOP OV 018.01 (návod firmy HACH/MERCK)
773 Water, purified water Measurement of temperature
Regulated area: 1 Basic chemistry
SOP OV 042 (ČSN 75 7342)
774 Drinking and hot water Sampling of drinking water
Regulated area: Sampling
SOP VZ OV 001 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
775 Bathing water Sampling of bathing water
Regulated area: Sampling
SOP VZ OV 002 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; ČSN 75 7717; Vyhláška č. 238/2011 Sb.)
776 Ground water Sampling of ground water – manual sampling and sampling by pumping
Regulated area: Sampling
SOP VZ OV 003 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)
777 Waste water Sampling of waste water – manual sampling and sampling with an automatic sampler
Regulated area: Sampling
SOP VZ OV 006 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
778 Purified water Sampling of purified water
Regulated area: Sampling
SOP VZ OV 008 (Vyhláška č. 84/2008 Sb.)
779 Surfaces, skin Sampling from surfaces of objects for determination of microbial contamination
Regulated area: Sampling
SOP VZ OV 206 (ČSN EN ISO 18593)
Ústí nad Orlicí
780 Workplace air Preliminary determination of gases and vapours by detection tubes
ammonia (NH3) chlorine (Cl2) nitrogen dioxide (NO2) nitric oxide (NO) hydrogen sulphide (H2S) sulphur dioxide (SO2) hydrogen cyanide (HCN) carbon dioxide (CO2) ozone (O3) carbon monoxide (CO) carbon disulphide (CS2) phenol nitrous gases (NOx) hydrogen (H2) hydrogen peroxide (H2O2)
Regulated area: 5 Air
SOP OV 424 (manuály firmy GASTEC a Dräger)
781 Indoor, outdoor and workplace air, compressed gases Measurement of concentration of gaseous pollutants – electrochemical method
sulphur dioxide (SO2) hydrogen sulphide (H2S) carbon monoxide (CO) nitric oxide (NO) nitrogen dioxide (NO2) oxygen (O2) ammonia (NH3)
Regulated area: 5 Air
SOP OV 438
782 Indoor, outdoor and workplace air, compressed gases Determination of carbon monoxide (CO) and carbon dioxide (CO2) with an infrared spectrometry analyzer
carbon monoxide (CO) carbon dioxide (CO2)
Regulated area: 5 Air
SOP OV 438.07
783 Indoor and workplace air Determination of vapours and gases by calculation from specified values
Regulated area: 5 Air
SOP OV 486 (Nařízení vlády č. 361/2007 Sb.; Vyhláška 43/2025 Sb.)
784 Working and non-working environment Measurement and calculation of noise
Regulated area: 6 Physical factors
Měření SOP OV 456, část 1; Výpočet SOP OV 456, část 2
785 Wind turbine generator systems Measurement of noise of wind turbine generator systems
Regulated area: 6 Physical factors
SOP OV 460 (ČSN EN 61400-11 ed. 3)
786 Noise source Determination of the sound power level
Regulated area: 6 Physical factors
SOP OV 462 (ČSN EN ISO 3744; ČSN EN ISO 3746; ČSN EN ISO 3747)
787 Indoor spaces Measurement of reverberation time
Regulated area: 6 Physical factors
SOP OV 464 (ČSN EN ISO 3382-2; ČSN EN ISO 3382-1)
788 Building structures Measurement of airborne sound insulation
Regulated area: 6 Physical factors
SOP OV 468
789 Building structures Measurement of impact sound insulation
Regulated area: 6 Physical factors
SOP OV 468.02
790 Working and non-working environment Measurement of vibration
Regulated area: 6 Physical factors
SOP OV 471
791 Outdoor and indoor air, compressed gases Sampling of outdoor and indoor air and compressed gases on a solid sorbent (filter, filter and PUF, sorption tube)
Regulated area: Sampling
SOP VZ OV 109 (Zákon o ochraně ovzduší 201/2012 Sb.; ČSN EN 12341; ČSN EN ISO 16000-7; Vyhláška č. 330/2012 Sb.)
792 Outdoor and indoor air Sampling of outdoor and indoor air into liquid (sorption solution, sedimentation vessel)
Regulated area: Sampling
SOP VZ OV 109.01 (Zákon o ochraně ovzduší 201/2012 Sb.)
793 Workplace air Sampling of workplace air on a solid sorbent (filter, filter and PUF, filter and sorbent, sorption tube)
Regulated area: Sampling
SOP VZ OV 110 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007Sb.)
794 Workplace air Sampling of workplace air into liquid (fritted absorbers with absorption solution)
Regulated area: Sampling
SOP VZ OV 110.01 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007 Sb.)
795 Workplace air Sampling of workplace air into canisters
Regulated area: Sampling
SOP VZ OV 110.02 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007 Sb.)
Nový Jičín
796 Indoor, outdoor and workplace air, compressed gases Measurement of concentration of gaseous pollutants – electrochemical method
sulphur dioxide (SO2) hydrogen sulphide (H2S) carbon monoxide (CO) nitric oxide (NO) nitrogen dioxide (NO2) oxygen (O2) ammonia (NH3)
Regulated area: 5 Air
SOP OV 438
797 Indoor, outdoor and workplace air, compressed gases Determination of carbon monoxide (CO) and carbon dioxide (CO2) with an infrared spectrometry analyzer
carbon monoxide (CO) carbon dioxide (CO2)
Regulated area: 5 Air
SOP OV 438.07
798 Indoor and workplace air Determination of vapours and gases by calculation from specified values
Regulated area: 5 Air
SOP OV 486 (Nařízení vlády č. 361/2007 Sb.; Vyhláška 43/2025 Sb.)
799 Working and non-working environment Measurement and calculation of noise
Regulated area: 6 Physical factors
Měření SOP OV 456, část 1; Výpočet SOP OV 456, část 2
800 Working and non-working environment Measurement of vibration
Regulated area: 6 Physical factors
SOP OV 471
801 Working and non-working environment, roads Measurement of electrical lighting
Regulated area: 6 Physical factors
SOP OV 469
802 Working and non-working environment Measurement of daylight
Regulated area: 6 Physical factors
SOP OV 470
803 Working and non-working environment, cleanrooms and clean zones Measurement of microclimatic conditions
globe temperature air temperature relative air humidity air velocity
operative temperature (calculated)
Regulated area: 6 Physical factors
SOP OV 474
804 Workplace air Sampling of workplace air on a solid sorbent (filter, filter and PUF, filter and sorbent, sorption tube)
Regulated area: Sampling
SOP VZ OV 110 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007Sb.)
805 Workplace air Sampling of workplace air into liquid (fritted absorbers with absorption solution)
Regulated area: Sampling
SOP VZ OV 110.01 (ČSN EN 482; ČSN EN 689+AC; Nařízení vlády č. 361/2007 Sb.)

Reference standards (476)

AHEM 1/2002
AHEM 1/2003
AHEM 1/2008
AHEM 1/2014
AHEM 13/1982
AHEM 2/88
AHEM 24/1986
AHEM 4/2021
AHEM 7/1992
AHEM 8/76
Aplikační list NICOLET
Aplikační listy PerkinElmer Simultaneous Direct Determination of 25 Metals in Urine with ICP-MS using Collision/Reaction Techmology
DIN 38414-17
EPA 552.3
EPA Method 535
EPA Method 536
EPA Method 8032A
EPA Method 8081
EPA Method TO-11A
EPA TO 13
EU Guidelines 2017
JPP ÚKZÚZ, Analýza půd III
Journal of Chromatography A, 1032, 2004, 79-85
Manuál MAS-100 CG Ex fy MBV, A.G.
Metoda AOAC 985.29 Total Dietary Fiber in Foods – Enzymatic-Gravimetric Method
NIOSH 7602
NIOSH Manual of Analytical Metods (NMAM), 8/1594
Nařízení Komise EU č. 10/2011
Nařízení vlády č. 361/2007 Sb.
Nařízení vlády č. 361/2007Sb.
OSHA Metod No. 42, No. 47
Pokyn hlavního hygienika ČR k zajištění jednotného postupu při kontrolách pískovišť venkovních hracích ploch, č.j. 3209/2014 ze dne 12.3.2014
Příloha č. 4/1985 k AHEM
SOP OV 001
SOP OV 002
SOP OV 002.01
SOP OV 002.03
SOP OV 003
SOP OV 003.01
SOP OV 003.02
SOP OV 005
SOP OV 006.02
SOP OV 006.05
SOP OV 006.06
SOP OV 006.07
SOP OV 007
SOP OV 007.01
SOP OV 007.03
SOP OV 008.01
SOP OV 011
SOP OV 012
SOP OV 013
SOP OV 014
SOP OV 015.01
SOP OV 015.02
SOP OV 015.03
SOP OV 016
SOP OV 018.01
SOP OV 019
SOP OV 020.02
SOP OV 022.01
SOP OV 024
SOP OV 024.01
SOP OV 025.01
SOP OV 026.01
SOP OV 028
SOP OV 032.02
SOP OV 033
SOP OV 033.01
SOP OV 033.02
SOP OV 034
SOP OV 036.01
SOP OV 040.01
SOP OV 040.02
SOP OV 041
SOP OV 042
SOP OV 042.01
SOP OV 044.01
SOP OV 045
SOP OV 046
SOP OV 049
SOP OV 049.02
SOP OV 051
SOP OV 055
SOP OV 055.01
SOP OV 055.02
SOP OV 058
SOP OV 062
SOP OV 062.01
SOP OV 064
SOP OV 064.01
SOP OV 064.02
SOP OV 064.03
SOP OV 064.04
SOP OV 064.05
SOP OV 064.06
SOP OV 064.07
SOP OV 064.08
SOP OV 064.09
SOP OV 064.10
SOP OV 064.11
SOP OV 064.12
SOP OV 064.13
SOP OV 081
SOP OV 083
SOP OV 084
SOP OV 085
SOP OV 104
SOP OV 108
SOP OV 110
SOP OV 114
SOP OV 118
SOP OV 120
SOP OV 122
SOP OV 123
SOP OV 124
SOP OV 125
SOP OV 130
SOP OV 132
SOP OV 134.01
SOP OV 200.03
SOP OV 201
SOP OV 201.01
SOP OV 201.03
SOP OV 201.04
SOP OV 201.05
SOP OV 201.06
SOP OV 201.10
SOP OV 201.11
SOP OV 202
SOP OV 300
SOP OV 301
SOP OV 302
SOP OV 303
SOP OV 303.01
SOP OV 304.01
SOP OV 305.01
SOP OV 305.04
SOP OV 307
SOP OV 307.02
SOP OV 309.01
SOP OV 309.04
SOP OV 309.07
SOP OV 313
SOP OV 316
SOP OV 323
SOP OV 324
SOP OV 327
SOP OV 327.01
SOP OV 327.12
SOP OV 327.14
SOP OV 331
SOP OV 331.01
SOP OV 331.02
SOP OV 331.05
SOP OV 331.06
SOP OV 333
SOP OV 333.06
SOP OV 335
SOP OV 336
SOP OV 338
SOP OV 338.01
SOP OV 340
SOP OV 341.02
SOP OV 343.02
SOP OV 344
SOP OV 344.01
SOP OV 344.12
SOP OV 357
SOP OV 360
SOP OV 381
SOP OV 383
SOP OV 385
SOP OV 401
SOP OV 403
SOP OV 404
SOP OV 405.01
SOP OV 424
SOP OV 436
SOP OV 436.01
SOP OV 436.03
SOP OV 438
SOP OV 438.03
SOP OV 438.04
SOP OV 438.05
SOP OV 438.07
SOP OV 452
SOP OV 455
SOP OV 456, část 1
SOP OV 456, část 2
SOP OV 460
SOP OV 462
SOP OV 464
SOP OV 468
SOP OV 468.02
SOP OV 469
SOP OV 470
SOP OV 471
SOP OV 474
SOP OV 486
SOP OV 487
SOP OV 503
SOP OV 505.01
SOP OV 603
SOP OV 608
SOP OV 609
SOP OV 801
SOP OV 802
SOP OV 805
SOP OV 806
SOP OV 807
SOP OV 808
SOP OV 811
SOP OV 900
SOP OV 901
SOP OV 902
SOP OV 903
SOP OV 904
SOP OV 906
SOP OV 907
SOP OV 908
SOP OV 909
SOP OV 910
SOP OV 911
SOP OV 912
SOP OV 913
SOP OV 914
SOP OV 914.03
SOP OV 915
SOP OV 916
SOP OV 917
SOP OV 918
SOP OV 918.01
SOP OV 919
SOP OV 920
SOP OV 921
SOP OV 922
SOP OV 923
SOP OV 924
SOP OV 925
SOP OV 927
SOP OV 928
SOP OV 929
SOP OV 929.01
SOP OV 930
SOP OV 931
SOP OV 933
SOP OV 933.01
SOP OV 933.02
SOP OV 936
SOP OV 983
SOP OV 984
SOP OV 985
SOP OV 986
SOP OV 988
SOP OV 990
SOP VZ OV 001
SOP VZ OV 002
SOP VZ OV 003
SOP VZ OV 005
SOP VZ OV 006
SOP VZ OV 008
SOP VZ OV 011
SOP VZ OV 012
SOP VZ OV 109
SOP VZ OV 109.01
SOP VZ OV 109.02
SOP VZ OV 109.03
SOP VZ OV 110
SOP VZ OV 110.01
SOP VZ OV 110.02
SOP VZ OV 200
SOP VZ OV 201
SOP VZ OV 204
SOP VZ OV 206
SOP VZ OV 213
SOP VZ OV 214
SOP VZ OV 217
SOP VZ OV 218
Simultaneous Determination of 28 elements in serum by ICP-MS using collision and reaction gases
TNI CEN/TR 15310-1
TNI CEN/TR 15310-2
TNI CEN/TR 15310-3
TNI CEN/TR 15310-4
TNI CEN/TR 15310-5
VDI 3492
VDI 3492, příloha D
VDI 3866, část 5
VYR-32 doplněk 1
Vyhláška 38/2001 Sb.
Vyhláška 43/2025 Sb.
Vyhláška č. 238/2011 Sb.
Vyhláška č. 330/2012 Sb.
Vyhláška č. 84/2008 Sb.
Zákon o ochraně ovzduší 201/2012 Sb.
manuál fy SPECTRO
manuály firmy GASTEC a Dräger
návod firmy HACH
návod firmy HACH/MERCK
návod firmy MERCK
návod firmy Thermo Scientific
návod firmy WTW
ČL, článek A, 11.4:0008
ČL, část 2.6.1
ČL, část 2.6.14
ČSN 01 5110
ČSN 01 5111
ČSN 01 5112
ČSN 46 5735
ČSN 56 0100:1970, kapitola VIII, články 144-148
ČSN 58 0111, část B, článek 16
ČSN 58 0120
ČSN 62 1156
ČSN 660805
ČSN 75 7315
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7350
ČSN 75 7358
ČSN 75 7360
ČSN 75 7367
ČSN 75 7372
ČSN 75 7373
ČSN 75 7415, postup A
ČSN 75 7440
ČSN 75 7505:1998
ČSN 75 7506
ČSN 75 7509
ČSN 75 7536
ČSN 75 7554:1998
ČSN 75 7611, kap. 4
ČSN 75 7612
ČSN 75 7624, kap. 6
ČSN 75 7712
ČSN 75 7713
ČSN 75 7717
ČSN 75 7835
ČSN EN 1186-3
ČSN EN 12341
ČSN EN 12673
ČSN EN 12766-1
ČSN EN 12856
ČSN EN 13137:2002
ČSN EN 13485
ČSN EN 13725
ČSN EN 14039
ČSN EN 14211
ČSN EN 14212
ČSN EN 14625
ČSN EN 14662-2
ČSN EN 1484
ČSN EN 14899
ČSN EN 14902
ČSN EN 15086
ČSN EN 15216
ČSN EN 15549
ČSN EN 15934, metoda A
ČSN EN 15935
ČSN EN 16166
ČSN EN 1622
ČSN EN 16450
ČSN EN 17503
ČSN EN 17892
ČSN EN 1899-2
ČSN EN 26461-2
ČSN EN 27888
ČSN EN 482
ČSN EN 61400-11 ed. 3
ČSN EN 689+AC
ČSN EN 872
ČSN EN 903
ČSN EN ISO 10272-1
ČSN EN ISO 10272-2
ČSN EN ISO 10304-1
ČSN EN ISO 10304-4
ČSN EN ISO 10390
ČSN EN ISO 10705-2
ČSN EN ISO 11269-1
ČSN EN ISO 11290-1
ČSN EN ISO 11290-2
ČSN EN ISO 11348-2
ČSN EN ISO 11731
ČSN EN ISO 11885
ČSN EN ISO 12966-1
ČSN EN ISO 12966-2
ČSN EN ISO 14184-1
ČSN EN ISO 14189
ČSN EN ISO 14402
ČSN EN ISO 14403-2
ČSN EN ISO 14644-1
ČSN EN ISO 15009
ČSN EN ISO 15061
ČSN EN ISO 15213-2
ČSN EN ISO 15680
ČSN EN ISO 15753
ČSN EN ISO 16000-7
ČSN EN ISO 16266
ČSN EN ISO 17075-1
ČSN EN ISO 17294-1
ČSN EN ISO 17294-2
ČSN EN ISO 17993
ČSN EN ISO 18412
ČSN EN ISO 18416
ČSN EN ISO 18475
ČSN EN ISO 18593
ČSN EN ISO 18856
ČSN EN ISO 18857-1
ČSN EN ISO 18857-2
ČSN EN ISO 19458
ČSN EN ISO 20236
ČSN EN ISO 21149
ČSN EN ISO 21150
ČSN EN ISO 21528-1
ČSN EN ISO 21528-2
ČSN EN ISO 22717
ČSN EN ISO 22718
ČSN EN ISO 3382-1
ČSN EN ISO 3382-2
ČSN EN ISO 3744
ČSN EN ISO 3746
ČSN EN ISO 3747
ČSN EN ISO 4614, část B
ČSN EN ISO 4833-1
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6341
ČSN EN ISO 6468
ČSN EN ISO 6579-1
ČSN EN ISO 6878
ČSN EN ISO 6888-1
ČSN EN ISO 7027-1
ČSN EN ISO 7899-2
ČSN EN ISO 7932
ČSN EN ISO 8467
ČSN EN ISO 8692
ČSN EN ISO 9308-1
ČSN EN ISO 9308-2
ČSN EN ISO 9377-2
ČSN EN ISO 9562
ČSN EN ISO 9963-1
ČSN ISO 10260
ČSN ISO 10359-1
ČSN ISO 10523
ČSN ISO 11083
ČSN ISO 11261
ČSN ISO 15705
ČSN ISO 16265
ČSN ISO 16649-2
ČSN ISO 17289
ČSN ISO 19250
ČSN ISO 21527-1
ČSN ISO 21527-2
ČSN ISO 4832
ČSN ISO 5664
ČSN ISO 5667-10
ČSN ISO 5667-11
ČSN ISO 5667-12
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 5667-7
ČSN ISO 6332
ČSN ISO 6439
ČSN ISO 6658
ČSN ISO 7150-1
ČSN ISO 939
ČSN P CEN ISO/TS 17728
ČSN P CEN/TS 13649
ČSN P CEN/TS 17083

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1393