🇨🇿 Severočeské vodovody a kanalizace, a.s. PL

ČIA 1372.3 • Teplice, Czech Republic • 294 methods

Water & wastewaterMicrobiologyEnvironment

Severočeské vodovody a kanalizace, a.s. is a laboratory accredited by ČIA under number 1372.3 (Teplice, Czech Republic). Its accreditation scope covers 294 test methods in the following areas: Water & wastewater, Microbiology, Environment. Test objects include: Drinking water, ground water, surface water, raw water and process…, Drinking water, ground water, surface water, raw water, process wat…, Bathing water, Drinking water, ground water, surface water and raw water.

At a glance

  • Accreditation number: ČIA 1372.3
  • Methods in scope: 294
  • Types of test objects: 64
  • City: Teplice, Czech Republic
  • Valid until: 10-03-2027
Accreditation number
1372.3
Accreditation body
ČIA
Address
Přítkovská 1689, 415 50 Teplice
City
Teplice, Czech Republic
Division
Dział kontroli jakości
Valid until
10-03-2027

What this laboratory tests (64)

Laboratory sections (7)

Laboratory locations

Certificate information

Certificate date
23.01.2026

Accreditation scope — test methods (294)

No. Test object Methodology / Parameters Technique Reference document
Laboratory Centre Most, Laboratory Most (P1)
1 Drinking water, ground water, surface water, raw water, process water and bathing water Biological analysis – determination of the microscopic picture
Regulated area: Tests
C.1.1/MO/15a (ČSN 75 7712)
2 Drinking water, ground water, surface water, raw water, process water and bathing water Biological analysis – microscopic determination of abioseston
Regulated area: Tests
C.1.1/MO/15b (ČSN 75 7713)
3 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of intestinal enterococci by membrane filtration
Regulated area: Tests
C.1.1/MO/19 (ČSN EN ISO 7899-2)
4 Drinking water, ground water, surface water, raw water and bathing water Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
C.1.1/MO/20 (ČSN 75 7835)
5 Drinking water, ground water, surface water, raw water, hot water, process water and bathing water Enumeration of culturable micro-organisms by culture at 22 °C and 36 °C
Regulated area: Tests
C.1.1/MO/21 (ČSN EN ISO 6222)
6 Drinking water, ground water, surface water, process water and raw water Determination of Clostridium perfringens by membrane filtration
Regulated area: Tests
C.1.1/MO/101 (ČSN EN ISO 14189)
7 Drinking water, ground water, surface water, raw water, process water, hot water and bathing water Determination of Escherichia coli and coliform bacteria by membrane filtration
Regulated area: Tests
C.1.1/MO/88 (ČSN EN ISO 9308-1)
8 Drinking water, ground water, surface water, raw water, hot water and bathing water Determination of Escherichia coli and coliform bacteria by the most probable number method
Regulated area: Tests
C.1.1/MO/17 (ČSN EN ISO 9308-2)
9 Hot water and bathing water Determination of Pseudomonas aeruginosa by membrane filtration
Regulated area: Tests
C.1.1/MO/61 (ČSN EN ISO 16266)
10 Bathing water Determination of coagulase-positive staphylococci by membrane filtration
Regulated area: Tests
C.1.1/MO/62 (ČSN EN ISO 6888-1)
11 Waste water, drinking water, ground water, surface water, raw water, process water, hot water, bathing water and liquid waste Determination of pH by potentiometry
Regulated area: Tests
C.1.1/MO/7a (ČSN ISO 10523)
12 Drinking water, surface water, ground water, raw water, process water, hot water and bathing water Determination of chemical oxygen demand by permanganate (CODMn) by manganometric titration
Regulated area: Tests
C.1.1/MO/11 (ČSN EN ISO 8467)
13 Drinking water, ground water, surface water, raw water, process water, hot water and bathing water Determination of turbidity by nephelometry
Regulated area: Tests
C.1.1/MO/91 (ČSN EN ISO 7027-1)
14 Waste water, drinking water, ground water, surface water, raw water and process water Determination of electrical conductivity by conductometry
Regulated area: Tests
C.1.1/MO/31 (ČSN EN 27888)
15 Waste water, drinking water, ground water, surface water, raw water and process water Determination of acid neutralizing capacity (KNK4,5) by acid-base titration
Regulated area: Tests
C.1.1/MO/37 (ČSN EN ISO 9963-1)
16 Drinking water, ground water, surface water and raw water Determination of humic substances by spectrophotometry after extraction
Regulated area: Tests
C.1.1/MO/39 (ČSN 75 7536)
17 Drinking water Sensory determination of taste
Regulated area: Tests
C.1.1/MO/43 (ČSN 75 7340)
18 Drinking water, ground water, surface water, raw water and hot water Sensory determination of odour
Regulated area: Tests
C.1.1/MO/44 (ČSN 75 7340)
19 Drinking water, ground water, surface water, raw water, process water and hot water Determination of colour by spectrophotometry
Regulated area: Tests
C.1.1/MO/46 (ČSN EN ISO 7887, metoda C)
20 Drinking water, ground water, surface water, raw water and process water Determination of base neutralizing capacity (ZNK8,3) by acid-base titration and calculation of free and aggressive carbon dioxide
Regulated area: Tests
C.1.1/MO/48 (ČSN 75 7372)
21 Ground water, surface water, raw water and process water Determination of absorbance at 254 nm by spectrophotometry
Regulated area: Tests
C.1.1/MO/52 (ČSN 75 7360)
22 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of ammonium ions by spectrophotometry using the Gallery automatic analyser and calculation of ammonium nitrogen
Regulated area: Tests
C.1.1/MO/80 (Postup firmy Thermo Fisher Scientific; ČSN ISO 7150-1; ČSN EN ISO 15923-1)
23 Drinking water, ground water, surface water, raw water and process water Determination of nitrites by spectrophotometry using the Gallery automatic analyser and calculation of nitrite nitrogen
Regulated area: Tests
C.1.1/MO/81 (Postup firmy Thermo Fisher Scientific; ČSN EN 26777; ČSN EN ISO 15923-1)
24 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of the sum of nitrate and nitrite nitrogen (TON) after reduction with hydrazine by spectrophotometry using the Gallery automatic analyser and calculation of nitrates and nitrate nitrogen
Regulated area: Tests
C.1.1/MO/82 (Postup firmy Thermo Fisher Scientific; EPA Method 353.1; ČSN EN ISO 15923-1)
25 Drinking water, ground water, surface water, raw water, hot water and process water Determination of orthophosphates by spectrophotometry with ammonium molybdate using the Gallery automatic analyser and calculation of phosphate phosphorus
Regulated area: Tests
C.1.1/MO/83 (Postup firmy Thermo Fisher Scientific; ČSN EN ISO 6878, čl. 4; ČSN EN ISO 15923-1)
26 Waste water, drinking water, ground water, surface water, raw water and process water Determination of chlorides by spectrophotometry using the Gallery automatic analyser
Regulated area: Tests
C.1.1/MO/84 (Postup firmy Thermo Fisher Scientific; ČSN EN ISO 15682; EPA Method 325.2; ČSN EN ISO 15923-1)
27 Waste water, drinking water, ground water, surface water, raw water and process water Determination of sulphates by turbidimetry using the Gallery automatic analyser
Regulated area: Tests
C.1.1/MO/85 (Postup firmy Thermo Fisher Scientific; EPA Method 375.4; ČSN EN ISO 15923-1)
28 Drinking water, ground water, surface water and raw water Determination of fluorides by spectrophotometry using the Gallery automatic analyser
Regulated area: Tests
C.1.1/MO/86 (Postup firmy Thermo Fisher Scientific; EPA Method 340.3)
29 Drinking water, ground water, surface water, raw water and bathing water Determination of oxidation-reduction potential (ORP) by potentiometry
Regulated area: Tests
C.1.1/MO/63 (ČSN 75 7367)
30 Drinking water, hot water and bathing water Determination of free and total chlorine by spectrophotometry using a HACH kit and calculation of combined chlorine
Regulated area: Tests
C.1.1/MO/40 (Metodika firmy HACH; ČSN EN ISO 7393-2)
31 Waste water, drinking water, ground water, surface water, raw water, hot water and bathing water Determination of temperature
Regulated area: Tests
C.1.1/MO/41 (ČSN 75 7342)
32 Waste water, ground water, surface water and raw water Determination of oxygen by electrochemical method
Regulated area: Tests
C.1.1/MO/60 (ČSN EN ISO 5814)
33 Bathing water Sensory determination of transparency
Regulated area: Tests
C.1.1/MO/97 (ČSN 75 7340; ČSN EN ISO 7027-2 čl. 5.2.1.1.)
34 Waste water, ground water, surface water, raw water and process water Determination of dissolved oxygen by luminescence method
Regulated area: Tests
C.1.1/MO/71 (Metodika firmy HACH; ČSN ISO 17289)
35 Waste water, ground water, surface water and raw water Determination of biochemical oxygen demand after n days (BODn) by luminescence
Regulated area: Tests
C.1.1/MO/96 (ČSN EN ISO 5815-1; ČSN ISO 17289)
36 Waste water, ground water, surface water, raw water and process water Determination of suspended solids by gravimetry – filtration through glass fibre filters
Regulated area: Tests
C.1.1/MO/4 (ČSN EN 872)
37 Waste water, ground water, surface water, raw water and liquid waste Determination of total phosphorus by spectrophotometry with ammonium molybdate
Regulated area: Tests
C.1.1/MO/5a (ČSN EN ISO 6878, čl. 7)
38 Waste water and liquid waste Determination of dissolved solids (RL) and residue on ignition (RAS) by gravimetry
Regulated area: Tests
C.1.1/MO/6 (ČSN 75 7346; ČSN 75 7347)
39 Sludge Determination of pH by potentiometry
Regulated area: Tests
C.1.1/MO/89 (ČSN EN ISO 10390)
40 Waste water, ground water, surface water, raw water and liquid waste Determination of total nitrogen by spectrophotometry using a HACH kit
Regulated area: Tests
C.1.1/MO/38 (Metodika firmy HACH)
41 Sludge and liquid waste Determination of dry matter (total solids) and loss on ignition by gravimetry
Regulated area: Tests
C.1.1/MO/56 (ČSN EN 12879:2001; ČSN EN 12880)
42 Sludge Determination of Kjeldahl nitrogen by titration after mineralization and distillation
Regulated area: Tests
C.1.1/MO/57 (ČSN EN 13342)
43 Waste water, ground water, surface water, raw water and process water Determination of anionic surfactants by spectrophotometry using a HACH kit
Regulated area: Tests
C.1.1/MO/79 (Metodika firmy HACH; ČSN EN 903)
44 Waste water, ground water, surface water, raw water and liquid waste Determination of chemical oxygen demand by dichromate (CODCr) by spectrophotometry using a HACH kit
Regulated area: Tests
C.1.1/MO/87 (ČSN ISO 15705; Metodika firmy HACH)
45 Process chemicals Determination of free (active) chlorine by spectrophotometry using a HACH kit
Regulated area: Tests
C.1.1/MO/103 (Metodika firmy HACH; ČSN EN ISO 7383-2; ČSN EN 901)
46 Waste water Determination of ammonium ions by continuous flow analysis with spectrophotometric detection and calculation of ammonium nitrogen and total inorganic nitrogen
Regulated area: Tests
C.1.1/MO/94 (ČSN EN ISO 11732; Metodika firmy Skalar)
47 Waste water Determination of nitrites and nitrates by continuous flow analysis with spectrophotometric detection and calculation of nitrogen forms
Regulated area: Tests
C.1.1/MO/95 (ČSN EN ISO 13395; Metodika firmy Skalar)
48 Waste water, ground water, surface water, raw water and liquid waste Determination of chemical oxygen demand by dichromate (CODCr) by spectrophotometry using a HACH kit – method with a Skalar robotic analyser
Regulated area: Tests
C.1.1/MO/98 (Metodika firmy HACH; ČSN ISO 15705; Metodika firmy Skalar)
49 Waste water, drinking water, ground water, surface water, raw water, process water, aqueous leachate, sludge, liquid waste, waste and sediments Determination of mercury by AMA 254 analyser
Regulated area: Tests
C.1.1/MO/28 (ČSN 75 7440; Manuál firmy Altec)
50 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of selected anions by liquid ion chromatography and calculation of the sum of chlorites and chlorates
bromates nitrates nitrites fluorides phosphates chlorates chlorides chlorites sulphates
Regulated area: Tests
C.1.1/MO/100 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061)
51 Process chemicals Determination of chlorites, chlorates and bromates by liquid ion chromatography
Regulated area: Tests
C.1.1/MO/102 (ČSN EN ISO 10304-4; ČSN EN ISO 15061; ČSN EN 901)
52 Waste water, drinking water, ground water, surface water, raw water, process water, hot water, bathing water and liquid waste Determination of selected elements by ICP-OES and calculation of the sum of calcium and magnesium
aluminium boron barium beryllium calcium cadmium cobalt chromium copper iron magnesium manganese nickel lead vanadium zinc phosphorus
Regulated area: Tests
C.1.1/MO/77 (ČSN EN ISO 11885; ČSN EN ISO 15587-1; ČSN EN ISO 15587-2)
53 Sludge, waste and sediments Determination of selected elements by ICP-OES
arsenic barium beryllium calcium cadmium cobalt chromium copper potassium magnesium molybdenum nickel lead vanadium zinc phosphorus
Regulated area: Tests
C.1.1/MO/78 (ČSN EN ISO 11885; ČSN EN 16173; ČSN EN ISO 54321)
54 Waste water, drinking water, ground water, surface water, raw water, process water, hot water, bathing water, aqueous leachate and liquid waste Determination of selected elements by ICP-MS and calculation of the sum of calcium and magnesium
aluminium boron barium beryllium potassium sodium arsenic selenium antimony molybdenum silver uranium calcium cadmium cobalt chromium copper iron magnesium manganese nickel lead vanadium zinc phosphorus
Regulated area: Tests
C.1.1/MO/92 (ČSN EN ISO 17294-2; ČSN EN ISO 15587-1; ČSN EN ISO 15587-2)
55 Sludge, waste and sediments Determination of selected elements by ICP-MS
barium beryllium cobalt potassium arsenic calcium cadmium chromium copper magnesium nickel molybdenum vanadium lead zinc phosphorus
Regulated area: Tests
C.1.1/MO/93 (ČSN EN ISO 17294-2; ČSN EN ISO 16173; ČSN EN ISO 54321; Manuál firmy Milestone)
56 Waste water, drinking water, ground water, surface water, raw water, hot water, bathing water and aqueous leachate Determination of total organic carbon (TOC), non-purgeable organic carbon (NPOC) and dissolved organic carbon (DOC) by high-temperature decomposition with IR detection
Regulated area: Tests
C.1.1/MO/42 (ČSN EN 1484)
57 Drinking water, ground water, surface water, raw water and hot water Determination of volatile organic compounds (VOC) by Purge & Trap gas chromatography and GC/FID+ECD and calculation of the sum of trihalomethanes
tetrachloromethane 1,2-dichloroethane trichloroethene bromodichloromethane tetrachloroethene dibromochloromethane tribromomethane (bromoform) trichloromethane (chloroform) benzene toluene chlorobenzene ethylbenzene m,p-xylene o-xylene
Regulated area: Tests
C.1.1/MO/49 (EPA Method 502.2)
58 Drinking water, ground water, surface water and raw water Determination of selected organochlorine pesticides (OCP) by GC/ECD and calculation of the sum of pesticide substances
hexachlorobenzene lindane heptachlor aldrin p,p-DDE dieldrin p,p-DDD methoxychlor p,p-DDT
Regulated area: Tests
C.1.1/MO/54 (EPA Method 505)
59 Ground water, surface water, raw water and waste water Determination of hydrocarbons C10 – C40 (non-polar extractable substances NELGC) by GC/FID after solvent extraction
Regulated area: Tests
C.1.1/MO/58 (ČSN EN ISO 9377-2)
60 Waste water, ground water, surface water and raw water Determination of extractable substances by gravimetry
Regulated area: Tests
C.1.1/MO/59 (ČSN 75 7508)
61 Sludge, waste and sediments Determination of volatile organic compounds (VOC) by Purge & Trap and GC/FID and calculation of the sum of BTEX and BTX
benzene toluene ethylbenzene m,p-xylene o-xylene
Regulated area: Tests
C.1.1/MO/72 (EPA Method 502.2; DIN ISO 15009)
62 Sludge, waste and sediments Determination of hydrocarbons C10 – C40 by GC/FID after solvent extraction
Regulated area: Tests
C.1.1/MO/73 (ČSN EN 14039)
63 Sludge, waste and sediments Determination of total organic carbon (TOC) by high-temperature decomposition with IR detection
Regulated area: Tests
C.1.1/MO/74 (ČSN EN 13137:2002; ČSN EN 15936)
64 Sludge, waste and sediments Determination of selected polychlorinated biphenyls (PCB) by GC/ECD after solvent extraction and calculation of the sum of PCB
PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180
Regulated area: Tests
C.1.1/MO/75 (ČSN EN 17322)
65 Waste and sediments Determination of dry matter in waste by gravimetry
Regulated area: Tests
C.1.1/MO/76 (ČSN EN 14346:2007)
66 Drinking water, ground water, surface water, raw water and process water Determination of selected analytes by LC/MS and calculation of the sum of selected substances
acetochlor alachlor atrazine desethylatrazine cyanazine desmetryn diazinon dimethoate hexazinone chlorfenvinphos metazachlor metolachlor prometryn propachlor propazine simazine terbutryn terbuthylazine desethylterbuthylazine bromoacetic acid bromochloroacetic acid bromodichloroacetic acid chloroacetic acid dibromoacetic acid dibromochloroacetic acid dichloroacetic acid tribromoacetic acid trichloroacetic acid
Regulated area: Tests
C.1.1/MO/99 (EPA Method 536; ČSN ISO 21676; Metodika firmy Bruker)
67 Waste water, drinking water, ground water, surface water, raw water, process water, aqueous leachate and liquid waste Determination of phenols by continuous flow analysis (CFA)
Regulated area: Tests
C.1.1/MO/104 (ČSN EN ISO 14402; Metodika firmy Skalar)
68 Waste water, drinking water, ground water, surface water, raw water and process water Determination of total cyanides by continuous flow analysis (CFA)
Regulated area: Tests
C.1.1/MO/105 (ČSN EN ISO 14403-2; Metodika firmy Skalar)
69 Waste water Determination of free cyanides by continuous flow analysis (CFA)
Regulated area: Tests
C.1.1/MO/107 (ČSN EN ISO 14403-2; Metodika firmy Skalar)
70 Waste water, drinking water, ground water, surface water, raw water, process water and liquid waste Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC-FLD and calculation of the sum of PAH
benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene benzo(ghi)perylene fluoranthene indeno(cd)pyrene
Regulated area: Tests
C.1.1/MO/106 (ČSN EN ISO 17993)
71 Sludge, waste and sediments Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC-FLD after QuEChERS extraction and calculation of the sum of PAH
naphthalene phenanthrene anthracene fluoranthene pyrene benzo(a)anthracene chrysene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene benzo(ghi)perylene indeno(cd)pyrene
Regulated area: Tests
C.1.1/MO/108 (ČSN EN ISO 17503)
72 Drinking water, raw water, process water and hot water Sampling of drinking, raw, process and hot water
Regulated area: Sampling
C.2.1/ÚKJ/1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN ISO 5667-21; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.)
73 Waste water Sampling of waste water (manually and by automatic sampler)
Regulated area: Sampling
C.2.1/ÚKJ/2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
74 Sludge Sampling of sludge from wastewater and water treatment plants
Regulated area: Sampling
C.2.1/ÚKJ/3 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ČSN EN 16179)
75 Bathing water Sampling of bathing water
Regulated area: Sampling
C.2.1/ÚKJ/4 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 238/2011 Sb.)
76 Waste Sampling of solid waste
Regulated area: Sampling
C.2.1/ÚKJ/5 (ČSN EN ISO 5667-15; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008); Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006))
77 Sediment Sampling of sediments
Regulated area: Sampling
C.2.1/ÚKJ/7 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-15; ČSN ISO 5667-12; Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006))
78 Liquid waste Sampling of liquid waste
Regulated area: Sampling
C.2.1/ÚKJ/8 (TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; ČSN EN 14899; ČSN EN ISO 5667-14; ČSN 01 5112; Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008))
Laboratory Centre Liberec, Laboratory Liberec (P2A)
79 Sludge Determination of indicator micro-organisms – enterococci, thermotolerant coliform bacteria, Salmonella – by culture
Regulated area: Tests
C.1.1/LB/12 (AHEM č.1/2008, Státní zdravotní ústav v Praze)
80 Drinking water, ground water, surface water, raw water, process water, hot water and bathing water Determination of Escherichia coli and coliform bacteria by the most probable number method
Regulated area: Tests
C.1.1/LB/13 (ČSN EN ISO 9308-2)
81 Hot water and bathing water Determination of Legionella by direct membrane filtration
Regulated area: Tests
C.1.1/LB/14 (ČSN EN ISO 11731)
82 Ground water, surface water, raw water and bathing water Determination of thermotolerant coliform bacteria by membrane filtration
Regulated area: Tests
C.1.1/LB/4 (ČSN 75 7835)
83 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of intestinal enterococci by membrane filtration
Regulated area: Tests
C.1.1/LB/5 (ČSN EN ISO 7899-2)
84 Drinking water, ground water, surface water, raw water and process water Biological analysis – determination of the microscopic picture
Regulated area: Tests
C.1.1/LB/11a (ČSN 75 7712)
85 Drinking water, ground water, surface water, raw water and process water Biological analysis – microscopic determination of abioseston
Regulated area: Tests
C.1.1/LB/11b (ČSN 75 7713)
86 Drinking water, ground water, surface water, raw water and process water Determination of Clostridium perfringens by membrane filtration
Regulated area: Tests
C.1.1/LB/8 (ČSN EN ISO 14189)
87 Drinking water, ground water, surface water, raw water, process water, hot water and bathing water Enumeration of culturable micro-organisms by culture at 22 °C and 36 °C
Regulated area: Tests
C.1.1/LB/7 (ČSN EN ISO 6222)
88 Drinking water, ground water, surface water, raw water, process water, hot water and bathing water Determination of Escherichia coli and coliform bacteria by membrane filtration
Regulated area: Tests
C.1.1/LB/1 (ČSN EN ISO 9308-1)
89 Hot water and bathing water Determination of Pseudomonas aeruginosa by membrane filtration
Regulated area: Tests
C.1.1/LB/9 (ČSN EN ISO 16266)
90 Hot water and bathing water Determination of coagulase-positive staphylococci by membrane filtration
Regulated area: Tests
C.1.1/LB/10 (ČSN EN ISO 6888-1)
91 Waste water, drinking water, ground water, surface water, raw water, process water, hot water and bathing water Determination of pH by potentiometry
Regulated area: Tests
C.1.1/LB/21a (ČSN ISO 10523)
92 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of electrical conductivity by conductometry
Regulated area: Tests
C.1.1/LB/22 (ČSN EN 27 888)
93 Drinking water, ground water, surface water, raw water and process water Determination of acid neutralizing capacity (KNK4,5) by acid-base titration
Regulated area: Tests
C.1.1/LB/23 (ČSN EN ISO 9963-1)
94 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of chlorides by argentometric titration
Regulated area: Tests
C.1.1/LB/24 (ČSN ISO 9297)
95 Drinking water, ground water, surface water, raw water, process water, hot water and bathing water Determination of chemical oxygen demand by permanganate (CODMn) by manganometric titration
Regulated area: Tests
C.1.1/LB/25 (ČSN EN ISO 8467)
96 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of nitrates by UV spectrophotometry and calculation of nitrate nitrogen
Regulated area: Tests
C.1.1/LB/26 (Vodní hospodářství 2/1988 B)
97 Drinking water, ground water, surface water, raw water and process water Determination of nitrites by spectrophotometry and calculation of nitrite nitrogen
Regulated area: Tests
C.1.1/LB/28 – A (ČSN EN 26777)
98 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of ammonium ions by spectrophotometry and calculation of ammonium nitrogen
Regulated area: Tests
C.1.1/LB/29 – A (ČSN ISO 7150-1)
99 Drinking water, ground water, surface water, raw water and process water Determination of aluminium by spectrophotometry with pyrocatechol violet
Regulated area: Tests
C.1.1/LB/30 (ČSN ISO 10566)
100 Waste water, drinking water, ground water, surface water, raw water and process water Determination of sulphates by turbidimetry with barium chloride
Regulated area: Tests
C.1.1/LB/31 (Vodní hospodářství 7/1984 B)
101 Waste water, drinking water, ground water, surface water, raw water, process water, aqueous leachate, sludge and liquid waste Determination of fluorides by potentiometry (ISE)
Regulated area: Tests
C.1.1/LB/32 (ČSN ISO 10359-1)
102 Drinking water, ground water, surface water, raw water, process water, hot water and bathing water Determination of colour by spectrophotometry
Regulated area: Tests
C.1.1/LB/103 (ČSN EN ISO 7887)
103 Drinking water, ground water, surface water, raw water and hot water Sensory determination of odour
Regulated area: Tests
C.1.1/LB/108 (ČSN 75 7340)
104 Drinking water Sensory determination of taste
Regulated area: Tests
C.1.1/LB/38 (ČSN 75 7340)
105 Waste water, ground water, surface water, raw water, process water and liquid waste Determination of adsorbable organically bound halogens (AOX) by microcoulometry
Regulated area: Tests
C.1.1/LB/107a (ČSN EN ISO 9562; TNI 75 7531)
106 Sludge, waste and sediments Determination of adsorbable organically bound halogens (AOX) by microcoulometry
Regulated area: Tests
C.1.1/LB/107b (ČSN EN 16166)
107 Waste water, drinking water, ground water, surface water, raw water, process water, hot water, aqueous leachate, sludge, waste, liquid waste and sediments Determination of mercury by AMA 254 analyser
Regulated area: Tests
C.1.1/LB/51 (ČSN 75 7440; Metodika firmy Altec)
108 Drinking water, ground water, surface water, raw water, process water and hot water Determination of calcium and magnesium by flame AAS and calculation of the sum of calcium and magnesium
Regulated area: Tests
C.1.1/LB/52 (ČSN ISO 7980)
109 Sludge, waste and sediments Determination of total dry matter by moisture analyser
Regulated area: Tests
C.1.1/LB/94 (Metodika firmy OHAUS)
110 Drinking water, process water and bathing water Determination of ozone by spectrophotometry using a HACH kit
Regulated area: Tests
C.1.1/LB/128 (Metodika firmy HACH)
111 Waste water, drinking water, ground water, surface water, raw water, process water and hot water Determination of iron and manganese by flame AAS
Regulated area: Tests
C.1.1/LB/53 (ČSN 75 7385)
112 Waste Determination of extractable organically bound halogens (EOX) by extraction
Regulated area: Tests
C.1.1/LB/48 (DIN 38414-17)
113 Drinking water, ground water, surface water, raw water, process water, hot water and bathing water Determination of turbidity by nephelometry
Regulated area: Tests
C.1.1/LB/42 (ČSN EN ISO 7027-1)
114 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of absorbance at 254 nm by spectrophotometry
Regulated area: Tests
C.1.1/LB/101 (ČSN 75 7360)
115 Drinking water, ground water, surface water, raw water and process water Determination of sulphates (SO42-) by turbidimetry using the BluVision automatic analyser
Regulated area: Tests
C.1.1/LB/54 (Metodika firmy Skalar; ČSN EN ISO 15923-1)
116 Drinking water, ground water, surface water, raw water and process water Determination of nitrites by spectrophotometry and calculation of nitrite nitrogen using the BluVision automatic analyser
Regulated area: Tests
C.1.1/LB/56 (Metodika firmy Skalar; ČSN EN ISO 15923-1)
117 Drinking water, ground water, surface water, raw water and process water Determination of ammonium ions by spectrophotometry and calculation of ammonium nitrogen using the BluVision automatic analyser
Regulated area: Tests
C.1.1/LB/57 (Metodika firmy Skalar; ČSN EN ISO 15923-1)
118 Drinking water, ground water, surface water, raw water, process water and hot water Determination of calcium by spectrophotometry using the BluVision automatic analyser and calculation of the sum of calcium and magnesium
Regulated area: Tests
C.1.1/LB/59 (Metodika firmy Skalar; ISO/TS 15923-2)
119 Drinking water, ground water, surface water, raw water, process water, hot water and bathing water Determination of free and total chlorine by spectrophotometry using a HACH kit and calculation of combined chlorine
Regulated area: Tests
C.1.1/LB/104 (Metodika firmy HACH; ČSN EN ISO 7393-2)
120 Waste water, drinking water, ground water, surface water, raw water, process water, hot water and bathing water Determination of temperature
Regulated area: Tests
C.1.1/LB/105 (ČSN 75 7342)
121 Waste water, process water, aqueous leachate and liquid waste Determination of chlorides by microcoulometric titration
Regulated area: Tests
C.1.1/LB/122 (Metodika firmy LABTECH; ČSN ISO 9297)
122 Drinking water, ground water, surface water, raw water, process water and hot water Determination of magnesium by spectrophotometry using the BluVision automatic analyser
Regulated area: Tests
C.1.1/LB/60 (Metodika firmy Skalar; ISO/TS 15923-2)
123 Drinking water, ground water, surface water, raw water, process water and hot water Determination of iron by spectrophotometry using the BluVision automatic analyser
Regulated area: Tests
C.1.1/LB/63 (Metodika firmy Skalar; ISO/TS 15923-2)
124 Waste water, ground water, surface water, raw water and process water Determination of oxygen by electrochemical method
Regulated area: Tests
C.1.1/LB/109 (ČSN EN ISO 5814)
125 Bathing water Determination of oxidation-reduction potential (ORP) by potentiometry
Regulated area: Tests
C.1.1/LB/125 (ČSN 75 7367)
126 Bathing water Sensory determination of transparency
Regulated area: Tests
C.1.1/LB/66 (ČSN 75 7340; ČSN EN ISO 7027-2, čl. 5.2.1.1.)
127 Waste water, drinking water, ground water, surface water, raw water, process water, bathing water and aqueous leachate Determination of total organic carbon (TOC), non-purgeable organic carbon (NPOC), inorganic carbon (TIC), total carbon (TC) and dissolved organic carbon (DOC) by high-temperature decomposition with IR detection
Regulated area: Tests
C.1.1/LB/50 (ČSN EN 1484)
128 Drinking water, ground water, surface water, raw water, process water and hot water Determination of manganese by spectrophotometry using the BluVision automatic analyser
Regulated area: Tests
C.1.1/LB/64 (Metodika firmy Skalar; ISO/TS 15923-2)
129 Drinking water, ground water, surface water, raw water and hot water Determination of phosphates by spectrophotometry using the BluVision automatic analyser
Regulated area: Tests
C.1.1/LB/65 (Metodika firmy Skalar; ČSN EN ISO 15923-1)
130 Drinking water, ground water, surface water and raw water Determination of humic substances by spectrophotometry after extraction
Regulated area: Tests
C.1.1/LB/110 (ČSN 75 7536)
131 Drinking water, ground water, surface water, raw water and process water Determination of chlorides by spectrophotometry using the BluVision automatic analyser
Regulated area: Tests
C.1.1/LB/95 (Metodika firmy Skalar; ČSN EN ISO 15923-1)
132 Drinking water, raw water, process water and hot water Sampling of drinking, raw, process and hot water
Regulated area: Sampling
C.2.1/ÚKJ/1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN ISO 5667-21; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.)
133 Bathing water Sampling of bathing water
Regulated area: Sampling
C.2.1/ÚKJ/4 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 238/2011 Sb.)
134 Surface water Sampling of surface water
Regulated area: Sampling
C.2.1/ÚKJ/6 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16)
Laboratory Centre Liberec, WWTP Laboratory Liberec (P2B)
135 Waste water, drinking water, raw water, surface water, ground water, process water, hot water, bathing water and liquid waste Determination of pH by potentiometry
Regulated area: Tests
C.1.1/LB/21a (ČSN ISO 10523)
136 Aqueous leachate Determination of pH by potentiometry
Regulated area: Tests
C.1.1/LB/46b (ČSN ISO 10523)
137 Sludge Determination of pH by potentiometry
Regulated area: Tests
C.1.1/LB/46c (ČSN ISO 10523; ČSN EN 12176:2014)
138 Waste water and process water Determination of nitrate nitrogen by spectrophotometry with sulfosalicylic acid
Regulated area: Tests
C.1.1/LB/27 (ČSN ISO 7890-3)
139 Waste water and process water Determination of nitrite nitrogen by spectrophotometry
Regulated area: Tests
C.1.1/LB/28 – B (ČSN EN 26777)
140 Waste water, process water and liquid waste Determination of ammonium nitrogen by spectrophotometry
Regulated area: Tests
C.1.1/LB/29 – B (ČSN ISO 7150-1)
141 Waste water, ground water, surface water, raw water, process water and liquid waste Determination of chemical oxygen demand by dichromate (CODCr) by spectrophotometry using a HACH kit
Regulated area: Tests
C.1.1/LB/33 (ČSN ISO 15705; Metodika firmy HACH)
142 Waste water, drinking water, ground water, surface water, raw water, process water, hot water and liquid waste Determination of orthophosphates and total phosphorus by spectrophotometry with ammonium molybdate and calculation of phosphorus pentoxide from total phosphorus
Regulated area: Tests
C.1.1/LB/34 (ČSN EN ISO 6878, čl. 4 a čl. 7)
143 Waste water, ground water, surface water, raw water and process water Determination of suspended solids by gravimetry – filtration through glass fibre filters
Regulated area: Tests
C.1.1/LB/35 (ČSN EN 872)
144 Waste water, ground water, surface water, raw water, aqueous leachate and liquid waste Determination of dissolved solids (RL) and ignited dissolved solids (RAS) by gravimetry
Regulated area: Tests
C.1.1/LB/36 (ČSN 75 7346; ČSN 75 7347; ČSN EN 15216)
145 Waste water, ground water, surface water, raw water, process water and liquid waste Determination of biochemical oxygen demand after n days (BODn) by electrochemical method
Regulated area: Tests
C.1.1/LB/62 (ČSN EN ISO 5815-1)
146 Waste water, ground water, surface water, raw water, process water and liquid waste Determination of total nitrogen by spectrophotometry using a HACH kit and calculation of organic and inorganic nitrogen
Regulated area: Tests
C.1.1/LB/43 (Metodika firmy HACH; ČSN EN ISO 11905-1)
147 Waste water Determination of anionic surfactants with methylene blue (MBAS) by spectrophotometry after extraction
Regulated area: Tests
C.1.1/LB/127 (ČSN EN 903)
148 Waste water Determination of Kjeldahl nitrogen by titration after mineralization and distillation and calculation of total, organic and inorganic nitrogen
Regulated area: Tests
C.1.1/LB/37a (ČSN EN 13342; ČSN EN 25663)
149 Sludge Determination of Kjeldahl nitrogen by titration after mineralization and distillation
Regulated area: Tests
C.1.1/LB/37b (ČSN EN 13342; ČSN EN 25663)
150 Waste water and process water Determination of temperature
Regulated area: Tests
C.1.1/LB/105 (ČSN 75 7342)
151 Waste water and aqueous leachate Determination of electrical conductivity by conductometry
Regulated area: Tests
C.1.1/LB/47 (ČSN EN 27888)
152 Waste water, sludge, waste, liquid waste and sediments Determination of total dry matter (total solids), residue on ignition and loss on ignition by gravimetry
Regulated area: Tests
C.1.1/LB/93 (ČSN EN 12880; ČSN EN 15934; ČSN EN 15935)
153 Waste water and liquid waste Determination of anionic surfactants by spectrophotometry using a HACH kit
Regulated area: Tests
C.1.1/LB/49 (Metodika firmy HACH; ČSN EN 903)
154 Waste water, ground water, surface water, raw water, process water and liquid waste Determination of biochemical oxygen demand after n days (BODn) by luminescence
Regulated area: Tests
C.1.1/LB/61 (ČSN EN ISO 5815-1; ČSN ISO 17289)
155 Waste water Sampling of waste water (manually and by automatic sampler)
Regulated area: Sampling
C.2.1/ÚKJ/2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
156 Sludge Sampling of sludge from wastewater and water treatment plants
Regulated area: Sampling
C.2.1/ÚKJ/3 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ČSN EN 16179)
157 Waste Sampling of solid waste
Regulated area: Sampling
C.2.1/ÚKJ/5 (ČSN EN ISO 5667-15; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008); Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006))
158 Sediment Sampling of sediments
Regulated area: Sampling
C.2.1/ÚKJ/7 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-15; ČSN ISO 5667-12; Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006))
159 Liquid waste Sampling of liquid waste
Regulated area: Sampling
C.2.1/ÚKJ/8 (TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; ČSN EN 14899; ČSN EN ISO 5667-14; ČSN 01 5112; Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008))
Laboratory Centre Ústí nad Labem, Water Treatment Plant Laboratory Velké Žernoseky (P3A)
160 Drinking water, ground water, surface water and raw water Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
C.1.1/UL/MB-8 (ČSN 75 7835)
161 Drinking water, ground water, surface water and raw water Determination of intestinal enterococci by membrane filtration
Regulated area: Tests
C.1.1/UL/MB-4 (ČSN EN ISO 7899-2)
162 Drinking water, ground water, surface water, raw water, process water, hot water and bathing water Determination of Escherichia coli and coliform bacteria by membrane filtration
Regulated area: Tests
C.1.1/UL/MB-13 (ČSN EN ISO 9308-1)
163 Drinking water, ground water, surface water, raw water, hot water, process water and bathing water Enumeration of culturable micro-organisms by culture at 22 °C and 36 °C
Regulated area: Tests
C.1.1/UL/MB-6 (ČSN EN ISO 6222)
164 Drinking water, ground water, surface water and raw water Determination of Clostridium perfringens by membrane filtration
Regulated area: Tests
C.1.1/UL/MB-14 (ČSN EN ISO 14189)
165 Drinking water, ground water, surface water, raw water, process water, hot water and bathing water Determination of Escherichia coli and coliform bacteria by the most probable number method
Regulated area: Tests
C.1.1/UL/MB-9 (ČSN EN ISO 9308-2)
166 Drinking water, ground water, surface water, raw water and process water Biological analysis – microscopic determination of living organisms and number of organisms
Regulated area: Tests
C.1.1/UL/BI-1A (ČSN 75 7712)
167 Drinking water, ground water, raw water and process water Biological analysis – microscopic determination of abioseston
Regulated area: Tests
C.1.1/UL/BI-2A (ČSN 75 7713)
168 Bathing water Determination of Pseudomonas aeruginosa by membrane filtration
Regulated area: Tests
C.1.1/UL/MB-10 (ČSN EN ISO 16266)
169 Bathing water Determination of coagulase-positive staphylococci by membrane filtration
Regulated area: Tests
C.1.1/UL/MB-11 (ČSN EN ISO 6888-1)
170 Hot water and bathing water Determination of Legionella by direct membrane filtration
Regulated area: Tests
C.1.1/UL/MB-12 (ČSN EN ISO 11731)
171 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of pH by potentiometry
Regulated area: Tests
C.1.1/UL/4A (ČSN ISO 10523)
172 Drinking water, ground water, surface water, raw water and process water Determination of chemical oxygen demand by permanganate (CODMn) by titration
Regulated area: Tests
C.1.1/UL/5A (ČSN EN ISO 8467)
173 Drinking water, ground water, surface water, raw water and process water Determination of acid neutralizing capacity (KNK4,5) by acid-base titration
Regulated area: Tests
C.1.1/UL/10 (ČSN EN ISO 9963-1)
174 Drinking water, ground water, surface water, raw water and process water Determination of iron by spectrophotometry with 1,10-phenanthroline
Regulated area: Tests
C.1.1/UL/12 (ČSN ISO 6332)
175 Drinking water, ground water, surface water, raw water and process water Determination of dissolved solids by gravimetry
Regulated area: Tests
C.1.1/UL/13 (ČSN 75 7346)
176 Drinking water, ground water, surface water, raw water and process water Determination of electrical conductivity by conductometry
Regulated area: Tests
C.1.1/UL/15 (ČSN EN 27888)
177 Drinking water, ground water, surface water, raw water and process water Determination of manganese by spectrophotometry with formaldoxime
Regulated area: Tests
C.1.1/UL/16 (ČSN ISO 6333)
178 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of turbidity by nephelometry
Regulated area: Tests
C.1.1/UL/61A (ČSN EN ISO 7027-1)
179 Drinking water, ground water, surface water and raw water Sensory determination of odour and taste
Regulated area: Tests
C.1.1/UL/23 (ČSN 75 7340; ČSN EN 1622)
180 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of free and total chlorine by spectrophotometry using a HACH kit and calculation of combined chlorine
Regulated area: Tests
C.1.1/UL/24 (Metodika firmy HACH; ČSN EN ISO 7393-2)
181 Waste water, drinking water, ground water, surface water, raw water, process water and bathing water Determination of temperature
Regulated area: Tests
C.1.1/UL/25 (ČSN 757342)
182 Drinking water, ground water, surface water, raw water and process water Determination of oxygen saturation by luminescence
Regulated area: Tests
C.1.1/UL/83 (Metodika firmy HACH; ČSN EN ISO 17289)
183 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of absorbance at 254 nm by spectrophotometry
Regulated area: Tests
C.1.1/UL/63 (ČSN 75 7360)
184 Drinking water, ground water, surface water, raw water and process water Determination of colour by spectrophotometry
Regulated area: Tests
C.1.1/UL/62 (ČSN EN ISO 7887)
185 Drinking water, ground water, surface water, raw water and process water Determination of humic substances by spectrophotometry after extraction
Regulated area: Tests
C.1.1/UL/71A (ČSN 75 7536)
186 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of nitrates by UV spectrophotometry
Regulated area: Tests
C.1.1/UL/72A (Vodní hospodářství č. 2/1988 – řada B)
187 Drinking water, ground water, surface water, raw water and process water Determination of ozone by spectrophotometry using a HACH kit
Regulated area: Tests
C.1.1/UL/46 (Metodika firmy HACH)
188 Drinking water, raw water, ground water, surface water, process water and bathing water Determination of oxidation-reduction potential (ORP) by potentiometry
Regulated area: Tests
C.1.1/UL/73 (ČSN 75 7367)
189 Bathing water Sensory determination of transparency
Regulated area: Tests
C.1.1/UL/89 (ČSN 75 7340; ČSN EN ISO 7027-2, čl. 5.2.1.1)
190 Drinking water, ground water, surface water, raw water and process water Determination of ammonium ions by spectrophotometry using the Gallery automatic analyser
Regulated area: Tests
C.1.1/UL/74 (Postup firmy Thermo Fisher Scientific; ČSN ISO 7150-1; ČSN EN ISO 15923-1)
191 Drinking water, ground water, surface water, raw water and process water Determination of nitrites by spectrophotometry using the Gallery automatic analyser
Regulated area: Tests
C.1.1/UL/75 (Postup firmy Thermo Fisher Scientific; ČSN EN ISO 15923-1; ČSN EN 26777)
192 Drinking water, ground water, surface water, raw water and process water Determination of nitrates by spectrophotometry using the Gallery automatic analyser
Regulated area: Tests
C.1.1/UL/76 (Postup firmy Thermo Fisher Scientific; ČSN EN ISO 15923-1; ČSN ISO 7890-3; EPA Method 353.1)
193 Drinking water, ground water, surface water, raw water and process water Determination of chlorides by spectrophotometry using the Gallery automatic analyser
Regulated area: Tests
C.1.1/UL/77 (Postup firmy Thermo Fisher Scientific; ČSN EN ISO 15923-1; ČSN 75 7422)
194 Drinking water, ground water, surface water, raw water and process water Determination of sulphates by spectrophotometry using the Gallery automatic analyser
Regulated area: Tests
C.1.1/UL/78 (Postup firmy Thermo Fisher Scientific; ČSN EN ISO 15923-1; EPA 375.4)
195 Drinking water, ground water, surface water, raw water and process water Determination of orthophosphates by spectrophotometry with ammonium molybdate using the Gallery automatic analyser
Regulated area: Tests
C.1.1/UL/79 (Postup firmy Thermo Fisher Scientific; ČSN EN ISO 15923-1; ČSN EN ISO 6878, čl. 4)
196 Drinking water, ground water, surface water, raw water and process water Determination of calcium by spectrophotometry using the Gallery automatic analyser and calculation of the sum of calcium and magnesium
Regulated area: Tests
C.1.1/UL/80 (Postup firmy Thermo Fisher Scientific)
197 Drinking water, ground water, surface water, raw water and process water Determination of magnesium by spectrophotometry using the Gallery automatic analyser
Regulated area: Tests
C.1.1/UL/81 (Postup firmy Thermo Fisher Scientific)
198 Drinking water, ground water, surface water, raw water and process water Determination of iron by spectrophotometry using the Gallery automatic analyser
Regulated area: Tests
C.1.1/UL/84 (Postup firmy Thermo Fisher Scientific; ČSN ISO 6332)
199 Drinking water, ground water, surface water, raw water and process water Determination of aluminium by spectrophotometry using the Gallery automatic analyser
Regulated area: Tests
C.1.1/UL/85 (Postup firmy Thermo Fisher Scientific; ČSN ISO 10566)
200 Drinking water, ground water, surface water, raw water and process water Determination of fluorides by spectrophotometry using the Gallery automatic analyser
Regulated area: Tests
C.1.1/UL/86 (Postup firmy Thermo Fisher Scientific)
201 Drinking water, ground water, surface water, raw water and process water Determination of KNK4,5 by spectrophotometry using the Gallery automatic analyser
Regulated area: Tests
C.1.1/UL/87 (Postup firmy Thermo Fisher Scientific)
202 Drinking water, raw water, process water and hot water Sampling of drinking, raw, process and hot water
Regulated area: Sampling
C.2.1/ÚKJ/1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN ISO 5667-21; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.)
203 Bathing water Sampling of bathing water
Regulated area: Sampling
C.2.1/ÚKJ/4 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 238/2011 Sb.)
Laboratory Centre Ústí nad Labem, WWTP Laboratory Neštěmice (P3B)
204 Waste water, ground water, surface water and raw water Determination of ammonium ions by spectrophotometry and calculation of ammonium and inorganic nitrogen
Regulated area: Tests
C.1.1/UL/1B (ČSN ISO 7150-1)
205 Waste water and raw water Determination of nitrates by spectrophotometry with sulfosalicylic acid and calculation of nitrate nitrogen
Regulated area: Tests
C.1.1/UL/2B (ČSN ISO 7890-3)
206 Waste water and raw water Determination of nitrites by spectrophotometry and calculation of nitrite nitrogen
Regulated area: Tests
C.1.1/UL/3B (ČSN EN 26777)
207 Waste water, raw water and liquid waste Determination of pH by potentiometry
Regulated area: Tests
C.1.1/UL/4B (ČSN ISO 10523)
208 Waste water, ground water, surface water and raw water Determination of biochemical oxygen demand after n days (BODn) by luminescence
Regulated area: Tests
C.1.1/UL/88B (ČSN EN ISO 5815-1; ČSN ISO 17289)
209 Waste water, ground water, surface water, raw water and liquid waste Determination of total phosphorus by spectrophotometry with ammonium molybdate
Regulated area: Tests
C.1.1/UL/7 (ČSN EN ISO 6878, čl. 7)
210 Waste water, ground water, surface water and raw water Determination of suspended solids by gravimetry – filtration through glass fibre filters
Regulated area: Tests
C.1.1/UL/8 (ČSN EN 872)
211 Waste water, raw water and liquid waste Determination of dissolved solids (RL) by gravimetry
Regulated area: Tests
C.1.1/UL/9 (ČSN 75 7346)
212 Waste water, ground water, surface water, raw water and liquid waste Determination of total nitrogen by oxidative digestion with peroxodisulphate by spectrophotometry using a HACH kit and calculation of organic nitrogen
Regulated area: Tests
C.1.1/UL/26 (Metodika firmy HACH)
213 Waste water, drinking water, ground water, surface water, raw water, process water and bathing water Determination of temperature
Regulated area: Tests
C.1.1/UL/25 (ČSN 75 7342)
214 Waste water and liquid waste Determination of dissolved inorganic salts (RAS) by gravimetry
Regulated area: Tests
C.1.1/UL/68B (ČSN 75 7347)
215 Waste water Determination of chlorides by titration
Regulated area: Tests
C.1.1/UL/14B (ČSN ISO 9297)
216 Waste water Determination of sulphates by turbidimetry
Regulated area: Tests
C.1.1/UL/19B (ASTM D 516-88)
217 Sludge Determination of pH by potentiometry
Regulated area: Tests
C.1.1/UL/57B (ČSN EN ISO 10390)
218 Sludge and liquid waste Determination of dry matter (total solids) by gravimetry
Regulated area: Tests
C.1.1/UL/58B (ČSN EN 12880)
219 Sludge Determination of loss on ignition by gravimetry
Regulated area: Tests
C.1.1/UL/59B (ČSN EN 12879:2001)
220 Waste water, ground water, surface water, raw water and liquid waste Determination of chemical oxygen demand by dichromate (CODCr) by spectrophotometry using a HACH kit
Regulated area: Tests
C.1.1/UL/60B (ČSN ISO 15705; Metodika firmy HACH)
221 Waste water Sampling of waste water (manually and by automatic sampler)
Regulated area: Sampling
C.2.1/ÚKJ/2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
222 Sludge Sampling of sludge from wastewater and water treatment plants
Regulated area: Sampling
C.2.1/ÚKJ/3 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ČSN EN 16179)
223 Waste Sampling of solid waste
Regulated area: Sampling
C.2.1/ÚKJ/5 (ČSN EN ISO 5667-15; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008); Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006))
224 Sediment Sampling of sediments
Regulated area: Sampling
C.2.1/ÚKJ/7 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-15; ČSN ISO 5667-12; Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006))
225 Liquid waste Sampling of liquid waste
Regulated area: Sampling
C.2.1/ÚKJ/8 (TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; ČSN EN 14899; ČSN EN ISO 5667-14; ČSN 01 5112; Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008))
Laboratory Centre Ústí nad Labem, Laboratory Děčín-Bynov (P3C)
226 Drinking water, ground water, surface water and raw water Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
C.1.1/UL/MB-57 (ČSN 75 7835)
227 Drinking water, ground water, surface water and raw water Determination of intestinal enterococci by membrane filtration
Regulated area: Tests
C.1.1/UL/MB-58 (ČSN EN ISO 7899-2)
228 Drinking water, ground water, surface water, raw water, process water, hot water and bathing water Determination of Escherichia coli and coliform bacteria by membrane filtration
Regulated area: Tests
C.1.1/UL/MB-65 (ČSN EN ISO 9308-1)
229 Drinking water, ground water, surface water, raw water, hot water and bathing water Enumeration of culturable micro-organisms by culture at 22 °C and 36 °C
Regulated area: Tests
C.1.1/UL/MB-60 (ČSN EN ISO 6222)
230 Drinking water, ground water, surface water and raw water Determination of Clostridium perfringens by membrane filtration
Regulated area: Tests
C.1.1/UL/MB-66 (ČSN EN ISO 14189)
231 Drinking water, ground water, surface water, raw water, hot water, process water and bathing water Determination of Escherichia coli and coliform bacteria by the most probable number method
Regulated area: Tests
C.1.1/UL/MB-62 (ČSN EN ISO 9308-2)
232 Drinking water, ground water, surface water and raw water Biological analysis – microscopic determination of living organisms and number of organisms
Regulated area: Tests
C.1.1/UL/BI-1C (ČSN 75 7712)
233 Drinking water, ground water, surface water, raw water and process water Biological analysis – microscopic determination of abioseston
Regulated area: Tests
C.1.1/UL/BI-2C (ČSN 75 7713)
234 Bathing water Determination of Pseudomonas aeruginosa by membrane filtration
Regulated area: Tests
C.1.1/UL/MB-63 (ČSN EN ISO 16266)
235 Bathing water Determination of coagulase-positive staphylococci by membrane filtration
Regulated area: Tests
C.1.1/UL/MB-64 (ČSN EN ISO 6888-1)
236 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of ammonium ions by spectrophotometry
Regulated area: Tests
C.1.1/UL/27 (ČSN ISO 7150-1)
237 Drinking water, ground water, surface water, raw water and process water Determination of nitrites by spectrophotometry
Regulated area: Tests
C.1.1/UL/29 (ČSN EN 26777)
238 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of pH by potentiometry
Regulated area: Tests
C.1.1/UL/30 (ČSN ISO 10523)
239 Drinking water, ground water, surface water, raw water and process water Determination of chemical oxygen demand by permanganate (CODMn) by manganometric titration
Regulated area: Tests
C.1.1/UL/31 (ČSN EN ISO 8467)
240 Drinking water, ground water, surface water, raw water and process water Determination of acid neutralizing capacity (KNK4,5) by acid-base titration
Regulated area: Tests
C.1.1/UL/32 (ČSN EN ISO 9963-1)
241 Drinking water, ground water, surface water, raw water and process water Determination of aluminium by spectrophotometry with pyrocatechol violet
Regulated area: Tests
C.1.1/UL/33 (ČSN ISO 10566)
242 Drinking water, ground water, surface water, raw water and process water Determination of iron by spectrophotometry with 1,10-phenanthroline
Regulated area: Tests
C.1.1/UL/34 (ČSN ISO 6332)
243 Drinking water, ground water, surface water, raw water and process water Determination of dissolved solids by gravimetry
Regulated area: Tests
C.1.1/UL/35 (ČSN 75 7346)
244 Drinking water, ground water, surface water, raw water and process water Determination of chlorides by mercurimetric titration
Regulated area: Tests
C.1.1/UL/36 (AOAC 973.51)
245 Drinking water, ground water, surface water, raw water and process water Determination of electrical conductivity by conductometry
Regulated area: Tests
C.1.1/UL/37 (ČSN EN 27888)
246 Drinking water, ground water, surface water, raw water and process water Determination of manganese by spectrophotometry with formaldoxime
Regulated area: Tests
C.1.1/UL/38 (ČSN ISO 6333)
247 Drinking water, ground water, surface water, raw water and process water Determination of the sum of calcium and magnesium by EDTA titration and calculation of magnesium
Regulated area: Tests
C.1.1/UL/39 (ČSN ISO 6059)
248 Drinking water, ground water, surface water, raw water and process water Determination of calcium by EDTA titration
Regulated area: Tests
C.1.1/UL/40 (ČSN ISO 6058)
249 Drinking water, ground water, surface water, raw water and process water Determination of fluorides by electrochemical method
Regulated area: Tests
C.1.1/UL/42 (ČSN ISO 10359-1)
250 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of turbidity by nephelometry
Regulated area: Tests
C.1.1/UL/61C (ČSN EN ISO 7027-1)
251 Drinking water, ground water, surface water and raw water Sensory determination of odour and taste
Regulated area: Tests
C.1.1/UL/44 (ČSN 75 7340; ČSN EN 1622)
252 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of free and total chlorine by spectrophotometry using a HACH kit and calculation of combined chlorine
Regulated area: Tests
C.1.1/UL/24 (Metodika firmy HACH; ČSN EN ISO 7393-2)
253 Waste water, drinking water, ground water, surface water, raw water, process water and bathing water Determination of temperature
Regulated area: Tests
C.1.1/UL/25 (ČSN 75 7342)
254 Drinking water, surface water, ground water, raw water and process water Determination of oxygen saturation by luminescence
Regulated area: Tests
C.1.1/UL/83 (Metodika firmy HACH; ČSN ISO 17289)
255 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of absorbance at 254 nm by spectrophotometry
Regulated area: Tests
C.1.1/UL/69 (ČSN 75 7360)
256 Drinking water, ground water, surface water, raw water and process water Determination of colour by spectrophotometry
Regulated area: Tests
C.1.1/UL/66 (ČSN EN ISO 7887)
257 Drinking water, ground water, surface water, raw water and process water Determination of orthophosphates by spectrophotometry with ammonium molybdate
Regulated area: Tests
C.1.1/UL/64 (ČSN EN ISO 6878, čl. 4)
258 Drinking water, ground water, surface water, raw water and process water Determination of humic substances by spectrophotometry after extraction
Regulated area: Tests
C.1.1/UL/71C (ČSN 75 7536)
259 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of nitrates by UV spectrophotometry
Regulated area: Tests
C.1.1/UL/72C (Vodní hospodářství 2/1988 – řada B)
260 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of oxidation-reduction potential (ORP) by potentiometry
Regulated area: Tests
C.1.1/UL/73 (ČSN 75 7367)
261 Bathing water Sensory determination of transparency
Regulated area: Tests
C.1.1/UL/89 (ČSN 75 7340; ČSN EN ISO 7027-2, čl. 5.2.1.1.)
262 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of total organic carbon (TOC) by high-temperature decomposition with IR detection
Regulated area: Tests
C.1.1/UL/82 (ČSN EN 1484)
263 Drinking water, ground water, surface water, raw water, process water and bathing water Determination of ammonium ions by spectrophotometry using the BluVision automatic analyser
Regulated area: Tests
C.1.1/UL/90 (Metodika firmy Skalar; ČSN ISO 7150-1; ČSN EN ISO 15923-1)
264 Drinking water, ground water, surface water, raw water and process water Determination of nitrites by spectrophotometry using the BluVision automatic analyser
Regulated area: Tests
C.1.1/UL/91 (Metodika firmy Skalar; ČSN EN 26777; ČSN EN ISO 15923-1)
265 Drinking water, ground water, surface water, raw water and process water Determination of orthophosphates by spectrophotometry with ammonium molybdate using the BluVision automatic analyser
Regulated area: Tests
C.1.1/UL/92 (Metodika firmy Skalar; ČSN EN ISO 6878, čl. 4; ČSN EN ISO 15923-1)
266 Drinking water, ground water, surface water, raw water and process water Determination of sulphates by turbidimetry using the BluVision automatic analyser
Regulated area: Tests
C.1.1/UL/93 (Metodika firmy Skalar; ČSN EN ISO 15923-1)
267 Drinking water, ground water, surface water, raw water and process water Determination of aluminium by spectrophotometry with pyrocatechol violet using the BluVision automatic analyser
Regulated area: Tests
C.1.1/UL/94 (Metodika firmy Skalar; ČSN ISO 10566; ISO/TS 15923-2)
268 Drinking water, ground water, surface water, raw water and process water Determination of iron by spectrophotometry using the BluVision automatic analyser
Regulated area: Tests
C.1.1/UL/95 (Metodika firmy Skalar; ČSN ISO 6332; ISO/TS 15923-2)
269 Drinking water, ground water, surface water, raw water and process water Determination of manganese by spectrophotometry using the BluVision automatic analyser
Regulated area: Tests
C.1.1/UL/96 (Metodika firmy Skalar; ČSN ISO 6333; ISO/TS 15923-2)
270 Drinking water, ground water, surface water, raw water and process water Determination of calcium by spectrophotometry using the BluVision automatic analyser and calculation of the sum of calcium and magnesium
Regulated area: Tests
C.1.1/UL/97 (Metodika firmy Skalar; ISO/TS 15923-2)
271 Drinking water, ground water, surface water, raw water and process water Determination of magnesium by spectrophotometry using the BluVision automatic analyser
Regulated area: Tests
C.1.1/UL/98 (Metodika firmy Skalar; ISO/TS 15923-2)
272 Drinking water, raw water, process water and hot water Sampling of drinking, raw, process and hot water
Regulated area: Sampling
C.2.1/ÚKJ/1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN ISO 5667-21; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.)
273 Bathing water Sampling of bathing water
Regulated area: Sampling
C.2.1/ÚKJ/4 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 238/2011 Sb.)
Laboratory Centre Ústí nad Labem, WWTP Laboratory Česká Lípa (P3D)
274 Waste water and raw water Determination of ammonium ions by spectrophotometry and calculation of ammonium and inorganic nitrogen
Regulated area: Tests
C.1.1/UL/47 (ČSN ISO 7150-1)
275 Waste water and raw water Determination of nitrates by spectrophotometry with sulfosalicylic acid and calculation of nitrate nitrogen
Regulated area: Tests
C.1.1/UL/48 (ČSN ISO 7890-3)
276 Waste water and raw water Determination of nitrites by spectrophotometry and calculation of nitrite nitrogen
Regulated area: Tests
C.1.1/UL/49 (ČSN EN 26777)
277 Waste water, raw water and liquid waste Determination of pH by potentiometry
Regulated area: Tests
C.1.1/UL/50 (ČSN ISO 10523)
278 Waste water, ground water, surface water and raw water Determination of biochemical oxygen demand after n days (BODn) by luminescence
Regulated area: Tests
C.1.1/UL/88D (ČSN EN ISO 5815-1; ČSN ISO 17289)
279 Waste water, ground water, surface water, raw water and liquid waste Determination of total phosphorus by spectrophotometry with ammonium molybdate
Regulated area: Tests
C.1.1/UL/53 (ČSN EN ISO 6878, čl. 7)
280 Waste water, ground water, surface water and raw water Determination of suspended solids (NL) by gravimetry – filtration through glass fibre filters
Regulated area: Tests
C.1.1/UL/54 (ČSN EN 872)
281 Waste water, raw water and liquid waste Determination of dissolved solids (RL) by gravimetry
Regulated area: Tests
C.1.1/UL/55 (ČSN 75 7346)
282 Waste water, ground water, surface water, raw water and liquid waste Determination of total nitrogen by oxidative digestion with peroxodisulphate by spectrophotometry using a HACH kit and calculation of organic nitrogen
Regulated area: Tests
C.1.1/UL/56 (Metodika firmy HACH)
283 Waste water, drinking water, ground water, surface water, raw water, process water and bathing water Determination of temperature
Regulated area: Tests
C.1.1/UL/25 (ČSN 75 7342)
284 Waste water and liquid waste Determination of dissolved inorganic salts (RAS) by gravimetry
Regulated area: Tests
C.1.1/UL/68D (ČSN 75 7347)
285 Sludge Determination of pH by potentiometry
Regulated area: Tests
C.1.1/UL/57D (ČSN EN ISO 10390)
286 Sludge and liquid waste Determination of dry matter (total solids) by gravimetry
Regulated area: Tests
C.1.1/UL/58D (ČSN EN 12880)
287 Sludge Determination of loss on ignition by gravimetry
Regulated area: Tests
C.1.1/UL/59D (ČSN EN 12879:2001)
288 Waste water, ground water, surface water, raw water and liquid waste Determination of chemical oxygen demand by dichromate (CODCr) by spectrophotometry using a HACH kit
Regulated area: Tests
C.1.1/UL/60D (ČSN ISO 15705; Metodika firmy HACH)
289 Waste water Determination of colour by spectrophotometry
Regulated area: Tests
C.1.1/UL/65 (ČSN EN ISO 7887)
290 Waste water Sampling of waste water (manually and by automatic sampler)
Regulated area: Sampling
C.2.1/ÚKJ/2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
291 Sludge Sampling of sludge from wastewater and water treatment plants
Regulated area: Sampling
C.2.1/ÚKJ/3 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ČSN EN 16179)
292 Waste Sampling of solid waste
Regulated area: Sampling
C.2.1/ÚKJ/5 (ČSN EN ISO 5667-15; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008); Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006))
293 Sediment Sampling of sediments
Regulated area: Sampling
C.2.1/ÚKJ/7 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-15; ČSN ISO 5667-12; Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006))
294 Liquid waste Sampling of liquid waste
Regulated area: Sampling
C.2.1/ÚKJ/8 (TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; ČSN EN 14899; ČSN EN ISO 5667-14; ČSN 01 5112; Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008))

Reference standards (416)

AHEM č.1/2008, Státní zdravotní ústav v Praze
AOAC 973.51
ASTM D 516-88
C.1.1/LB/1
C.1.1/LB/10
C.1.1/LB/101
C.1.1/LB/103
C.1.1/LB/104
C.1.1/LB/105
C.1.1/LB/107a
C.1.1/LB/107b
C.1.1/LB/108
C.1.1/LB/109
C.1.1/LB/110
C.1.1/LB/11a
C.1.1/LB/11b
C.1.1/LB/12
C.1.1/LB/122
C.1.1/LB/125
C.1.1/LB/127
C.1.1/LB/128
C.1.1/LB/13
C.1.1/LB/14
C.1.1/LB/21a
C.1.1/LB/22
C.1.1/LB/23
C.1.1/LB/24
C.1.1/LB/25
C.1.1/LB/26
C.1.1/LB/27
C.1.1/LB/28 – A
C.1.1/LB/28 – B
C.1.1/LB/29 – A
C.1.1/LB/29 – B
C.1.1/LB/30
C.1.1/LB/31
C.1.1/LB/32
C.1.1/LB/33
C.1.1/LB/34
C.1.1/LB/35
C.1.1/LB/36
C.1.1/LB/37a
C.1.1/LB/37b
C.1.1/LB/38
C.1.1/LB/4
C.1.1/LB/42
C.1.1/LB/43
C.1.1/LB/46b
C.1.1/LB/46c
C.1.1/LB/47
C.1.1/LB/48
C.1.1/LB/49
C.1.1/LB/5
C.1.1/LB/50
C.1.1/LB/51
C.1.1/LB/52
C.1.1/LB/53
C.1.1/LB/54
C.1.1/LB/56
C.1.1/LB/57
C.1.1/LB/59
C.1.1/LB/60
C.1.1/LB/61
C.1.1/LB/62
C.1.1/LB/63
C.1.1/LB/64
C.1.1/LB/65
C.1.1/LB/66
C.1.1/LB/7
C.1.1/LB/8
C.1.1/LB/9
C.1.1/LB/93
C.1.1/LB/94
C.1.1/LB/95
C.1.1/MO/100
C.1.1/MO/101
C.1.1/MO/102
C.1.1/MO/103
C.1.1/MO/104
C.1.1/MO/105
C.1.1/MO/106
C.1.1/MO/107
C.1.1/MO/108
C.1.1/MO/11
C.1.1/MO/15a
C.1.1/MO/15b
C.1.1/MO/17
C.1.1/MO/19
C.1.1/MO/20
C.1.1/MO/21
C.1.1/MO/28
C.1.1/MO/31
C.1.1/MO/37
C.1.1/MO/38
C.1.1/MO/39
C.1.1/MO/4
C.1.1/MO/40
C.1.1/MO/41
C.1.1/MO/42
C.1.1/MO/43
C.1.1/MO/44
C.1.1/MO/46
C.1.1/MO/48
C.1.1/MO/49
C.1.1/MO/52
C.1.1/MO/54
C.1.1/MO/56
C.1.1/MO/57
C.1.1/MO/58
C.1.1/MO/59
C.1.1/MO/5a
C.1.1/MO/6
C.1.1/MO/60
C.1.1/MO/61
C.1.1/MO/62
C.1.1/MO/63
C.1.1/MO/71
C.1.1/MO/72
C.1.1/MO/73
C.1.1/MO/74
C.1.1/MO/75
C.1.1/MO/76
C.1.1/MO/77
C.1.1/MO/78
C.1.1/MO/79
C.1.1/MO/7a
C.1.1/MO/80
C.1.1/MO/81
C.1.1/MO/82
C.1.1/MO/83
C.1.1/MO/84
C.1.1/MO/85
C.1.1/MO/86
C.1.1/MO/87
C.1.1/MO/88
C.1.1/MO/89
C.1.1/MO/91
C.1.1/MO/92
C.1.1/MO/93
C.1.1/MO/94
C.1.1/MO/95
C.1.1/MO/96
C.1.1/MO/97
C.1.1/MO/98
C.1.1/MO/99
C.1.1/UL/10
C.1.1/UL/12
C.1.1/UL/13
C.1.1/UL/14B
C.1.1/UL/15
C.1.1/UL/16
C.1.1/UL/19B
C.1.1/UL/1B
C.1.1/UL/23
C.1.1/UL/24
C.1.1/UL/25
C.1.1/UL/26
C.1.1/UL/27
C.1.1/UL/29
C.1.1/UL/2B
C.1.1/UL/30
C.1.1/UL/31
C.1.1/UL/32
C.1.1/UL/33
C.1.1/UL/34
C.1.1/UL/35
C.1.1/UL/36
C.1.1/UL/37
C.1.1/UL/38
C.1.1/UL/39
C.1.1/UL/3B
C.1.1/UL/40
C.1.1/UL/42
C.1.1/UL/44
C.1.1/UL/46
C.1.1/UL/47
C.1.1/UL/48
C.1.1/UL/49
C.1.1/UL/4A
C.1.1/UL/4B
C.1.1/UL/50
C.1.1/UL/53
C.1.1/UL/54
C.1.1/UL/55
C.1.1/UL/56
C.1.1/UL/57B
C.1.1/UL/57D
C.1.1/UL/58B
C.1.1/UL/58D
C.1.1/UL/59B
C.1.1/UL/59D
C.1.1/UL/5A
C.1.1/UL/60B
C.1.1/UL/60D
C.1.1/UL/61A
C.1.1/UL/61C
C.1.1/UL/62
C.1.1/UL/63
C.1.1/UL/64
C.1.1/UL/65
C.1.1/UL/66
C.1.1/UL/68B
C.1.1/UL/68D
C.1.1/UL/69
C.1.1/UL/7
C.1.1/UL/71A
C.1.1/UL/71C
C.1.1/UL/72A
C.1.1/UL/72C
C.1.1/UL/73
C.1.1/UL/74
C.1.1/UL/75
C.1.1/UL/76
C.1.1/UL/77
C.1.1/UL/78
C.1.1/UL/79
C.1.1/UL/8
C.1.1/UL/80
C.1.1/UL/81
C.1.1/UL/82
C.1.1/UL/83
C.1.1/UL/84
C.1.1/UL/85
C.1.1/UL/86
C.1.1/UL/87
C.1.1/UL/88B
C.1.1/UL/88D
C.1.1/UL/89
C.1.1/UL/9
C.1.1/UL/90
C.1.1/UL/91
C.1.1/UL/92
C.1.1/UL/93
C.1.1/UL/94
C.1.1/UL/95
C.1.1/UL/96
C.1.1/UL/97
C.1.1/UL/98
C.1.1/UL/BI-1A
C.1.1/UL/BI-1C
C.1.1/UL/BI-2A
C.1.1/UL/BI-2C
C.1.1/UL/MB-10
C.1.1/UL/MB-11
C.1.1/UL/MB-12
C.1.1/UL/MB-13
C.1.1/UL/MB-14
C.1.1/UL/MB-4
C.1.1/UL/MB-57
C.1.1/UL/MB-58
C.1.1/UL/MB-6
C.1.1/UL/MB-60
C.1.1/UL/MB-62
C.1.1/UL/MB-63
C.1.1/UL/MB-64
C.1.1/UL/MB-65
C.1.1/UL/MB-66
C.1.1/UL/MB-8
C.1.1/UL/MB-9
C.2.1/ÚKJ/1
C.2.1/ÚKJ/2
C.2.1/ÚKJ/3
C.2.1/ÚKJ/4
C.2.1/ÚKJ/5
C.2.1/ÚKJ/6
C.2.1/ÚKJ/7
C.2.1/ÚKJ/8
DIN 38414-17
DIN ISO 15009
EPA 375.4
EPA Method 325.2
EPA Method 340.3
EPA Method 353.1
EPA Method 375.4
EPA Method 502.2
EPA Method 505
EPA Method 536
ISO/TS 15923-2
Manuál firmy Altec
Manuál firmy Milestone
Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006)
Metodika firmy Altec
Metodika firmy Bruker
Metodika firmy HACH
Metodika firmy LABTECH
Metodika firmy OHAUS
Metodika firmy Skalar
Postup firmy Thermo Fisher Scientific
TNI 75 7531
TNI CEN/TR 15310-1
TNI CEN/TR 15310-2
TNI CEN/TR 15310-3
TNI CEN/TR 15310-4
TNI CEN/TR 15310-5
Vodní hospodářství 2/1988 B
Vodní hospodářství 2/1988 – řada B
Vodní hospodářství 7/1984 B
Vodní hospodářství č. 2/1988 – řada B
Vyhláška č. 238/2011 Sb.
Vyhláška č. 252/2004 Sb.
Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008)
ČSN 01 5112
ČSN 75 7315
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7360
ČSN 75 7367
ČSN 75 7372
ČSN 75 7385
ČSN 75 7422
ČSN 75 7440
ČSN 75 7508
ČSN 75 7536
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN 757342
ČSN EN 12176:2014
ČSN EN 12879:2001
ČSN EN 12880
ČSN EN 13137:2002
ČSN EN 13342
ČSN EN 14039
ČSN EN 14346:2007
ČSN EN 1484
ČSN EN 14899
ČSN EN 15216
ČSN EN 15934
ČSN EN 15935
ČSN EN 15936
ČSN EN 16166
ČSN EN 16173
ČSN EN 16179
ČSN EN 1622
ČSN EN 17322
ČSN EN 25663
ČSN EN 26777
ČSN EN 27 888
ČSN EN 27888
ČSN EN 872
ČSN EN 901
ČSN EN 903
ČSN EN ISO 10304-1
ČSN EN ISO 10304-4
ČSN EN ISO 10390
ČSN EN ISO 11731
ČSN EN ISO 11732
ČSN EN ISO 11885
ČSN EN ISO 11905-1
ČSN EN ISO 13395
ČSN EN ISO 14189
ČSN EN ISO 14402
ČSN EN ISO 14403-2
ČSN EN ISO 15061
ČSN EN ISO 15587-1
ČSN EN ISO 15587-2
ČSN EN ISO 15682
ČSN EN ISO 15923-1
ČSN EN ISO 16173
ČSN EN ISO 16266
ČSN EN ISO 17289
ČSN EN ISO 17294-2
ČSN EN ISO 17503
ČSN EN ISO 17993
ČSN EN ISO 19458
ČSN EN ISO 54321
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-16
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5814
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878, čl. 4
ČSN EN ISO 6878, čl. 4 a čl. 7
ČSN EN ISO 6878, čl. 7
ČSN EN ISO 6888-1
ČSN EN ISO 7027-1
ČSN EN ISO 7027-2 čl. 5.2.1.1.
ČSN EN ISO 7027-2, čl. 5.2.1.1
ČSN EN ISO 7027-2, čl. 5.2.1.1.
ČSN EN ISO 7383-2
ČSN EN ISO 7393-2
ČSN EN ISO 7887
ČSN EN ISO 7887, metoda C
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9308-2
ČSN EN ISO 9377-2
ČSN EN ISO 9562
ČSN EN ISO 9963-1
ČSN ISO 10359-1
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 15705
ČSN ISO 17289
ČSN ISO 21676
ČSN ISO 5667-10
ČSN ISO 5667-12
ČSN ISO 5667-21
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 7980
ČSN ISO 9297

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1372.3