🇨🇿 Severočeské vodovody a kanalizace, a.s. PL
Water & wastewaterMicrobiologyEnvironment
Severočeské vodovody a kanalizace, a.s. is a laboratory accredited by ČIA under number 1372.3 (Teplice, Czech Republic). Its accreditation scope covers 294 test methods in the following areas: Water & wastewater, Microbiology, Environment. Test objects include: Drinking water, ground water, surface water, raw water and process…, Drinking water, ground water, surface water, raw water, process wat…, Bathing water, Drinking water, ground water, surface water and raw water.
At a glance
- Accreditation number: ČIA 1372.3
- Methods in scope: 294
- Types of test objects: 64
- City: Teplice, Czech Republic
- Valid until: 10-03-2027
- Accreditation number
- 1372.3
- Accreditation body
- ČIA
- Address
- Přítkovská 1689, 415 50 Teplice
- City
- Teplice, Czech Republic
- Division
- Dział kontroli jakości
- Valid until
- 10-03-2027
What this laboratory tests (64)
- Drinking water, ground water, surface water, raw water and process water — 60 methods
- Drinking water, ground water, surface water, raw water, process water and bathing water — 26 methods
- Bathing water — 14 methods
- Drinking water, ground water, surface water and raw water — 13 methods
- Sludge — 13 methods
- Drinking water, ground water, surface water, raw water, process water, hot water and bathing water — 12 methods
- Waste water — 12 methods
- Waste water, ground water, surface water, raw water and liquid waste — 10 methods
- Sludge, waste and sediments — 9 methods
- Waste water, ground water, surface water and raw water — 8 methods
- Drinking water, ground water, surface water, raw water, process water and hot water — 6 methods
- Waste water, drinking water, ground water, surface water, raw water and process water — 6 methods
- Hot water and bathing water — 5 methods
- Waste — 5 methods
- Waste water and raw water — 5 methods
- and 49 more
Laboratory sections (7)
- Laboratory Centre Most, Laboratory Most (P1) — 78 methods
- Laboratory Centre Liberec, Laboratory Liberec (P2A) — 56 methods
- Laboratory Centre Ústí nad Labem, Laboratory Děčín-Bynov (P3C) — 48 methods
- Laboratory Centre Ústí nad Labem, Water Treatment Plant Laboratory Velké Žernoseky (P3A) — 44 methods
- Laboratory Centre Liberec, WWTP Laboratory Liberec (P2B) — 25 methods
- Laboratory Centre Ústí nad Labem, WWTP Laboratory Neštěmice (P3B) — 22 methods
- Laboratory Centre Ústí nad Labem, WWTP Laboratory Česká Lípa (P3D) — 21 methods
Laboratory locations
- Ośrodek laboratoriów Most, Laboratorium Most (P1) — Dělnická 161
- Ośrodek laboratoriów Liberec, Laboratorium Liberec (P2A) — Sladovnická 1082
- Ośrodek laboratoriów Liberec, Laboratorium oczyszczalni ścieków Liberec (P2B) — Londýnská 464/90a
- Ośrodek laboratoriów Ústí nad Labem, Laboratorium stacji uzdatniania Velké Žernoseky (P3A) — Píšťany
- Ośrodek laboratoriów Ústí nad Labem, Laboratorium oczyszczalni ścieków Neštěmice (P3B) — Veslařská
- Ośrodek laboratoriów Ústí nad Labem, Laboratorium Děčín-Bynov (P3C) — U Kotelny 350
- Ośrodek laboratoriów Ústí nad Labem, Laboratorium oczyszczalni ścieków Česká Lípa (P3D) — Pod Holým vrchem 3067
Certificate information
- Certificate date
- 23.01.2026
Accreditation scope — test methods (294)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory Centre Most, Laboratory Most (P1) | |||||
| 1 | Drinking water, ground water, surface water, raw water, process water and bathing water | Biological analysis – determination of the microscopic picture Regulated area: Tests |
C.1.1/MO/15a (ČSN 75 7712) | ||
| 2 | Drinking water, ground water, surface water, raw water, process water and bathing water | Biological analysis – microscopic determination of abioseston Regulated area: Tests |
C.1.1/MO/15b (ČSN 75 7713) | ||
| 3 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of intestinal enterococci by membrane filtration Regulated area: Tests |
C.1.1/MO/19 (ČSN EN ISO 7899-2) | ||
| 4 | Drinking water, ground water, surface water, raw water and bathing water | Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration Regulated area: Tests |
C.1.1/MO/20 (ČSN 75 7835) | ||
| 5 | Drinking water, ground water, surface water, raw water, hot water, process water and bathing water | Enumeration of culturable micro-organisms by culture at 22 °C and 36 °C Regulated area: Tests |
C.1.1/MO/21 (ČSN EN ISO 6222) | ||
| 6 | Drinking water, ground water, surface water, process water and raw water | Determination of Clostridium perfringens by membrane filtration Regulated area: Tests |
C.1.1/MO/101 (ČSN EN ISO 14189) | ||
| 7 | Drinking water, ground water, surface water, raw water, process water, hot water and bathing water | Determination of Escherichia coli and coliform bacteria by membrane filtration Regulated area: Tests |
C.1.1/MO/88 (ČSN EN ISO 9308-1) | ||
| 8 | Drinking water, ground water, surface water, raw water, hot water and bathing water | Determination of Escherichia coli and coliform bacteria by the most probable number method Regulated area: Tests |
C.1.1/MO/17 (ČSN EN ISO 9308-2) | ||
| 9 | Hot water and bathing water | Determination of Pseudomonas aeruginosa by membrane filtration Regulated area: Tests |
C.1.1/MO/61 (ČSN EN ISO 16266) | ||
| 10 | Bathing water | Determination of coagulase-positive staphylococci by membrane filtration Regulated area: Tests |
C.1.1/MO/62 (ČSN EN ISO 6888-1) | ||
| 11 | Waste water, drinking water, ground water, surface water, raw water, process water, hot water, bathing water and liquid waste | Determination of pH by potentiometry Regulated area: Tests |
C.1.1/MO/7a (ČSN ISO 10523) | ||
| 12 | Drinking water, surface water, ground water, raw water, process water, hot water and bathing water | Determination of chemical oxygen demand by permanganate (CODMn) by manganometric titration Regulated area: Tests |
C.1.1/MO/11 (ČSN EN ISO 8467) | ||
| 13 | Drinking water, ground water, surface water, raw water, process water, hot water and bathing water | Determination of turbidity by nephelometry Regulated area: Tests |
C.1.1/MO/91 (ČSN EN ISO 7027-1) | ||
| 14 | Waste water, drinking water, ground water, surface water, raw water and process water | Determination of electrical conductivity by conductometry Regulated area: Tests |
C.1.1/MO/31 (ČSN EN 27888) | ||
| 15 | Waste water, drinking water, ground water, surface water, raw water and process water | Determination of acid neutralizing capacity (KNK4,5) by acid-base titration Regulated area: Tests |
C.1.1/MO/37 (ČSN EN ISO 9963-1) | ||
| 16 | Drinking water, ground water, surface water and raw water | Determination of humic substances by spectrophotometry after extraction Regulated area: Tests |
C.1.1/MO/39 (ČSN 75 7536) | ||
| 17 | Drinking water | Sensory determination of taste Regulated area: Tests |
C.1.1/MO/43 (ČSN 75 7340) | ||
| 18 | Drinking water, ground water, surface water, raw water and hot water | Sensory determination of odour Regulated area: Tests |
C.1.1/MO/44 (ČSN 75 7340) | ||
| 19 | Drinking water, ground water, surface water, raw water, process water and hot water | Determination of colour by spectrophotometry Regulated area: Tests |
C.1.1/MO/46 (ČSN EN ISO 7887, metoda C) | ||
| 20 | Drinking water, ground water, surface water, raw water and process water | Determination of base neutralizing capacity (ZNK8,3) by acid-base titration and calculation of free and aggressive carbon dioxide Regulated area: Tests |
C.1.1/MO/48 (ČSN 75 7372) | ||
| 21 | Ground water, surface water, raw water and process water | Determination of absorbance at 254 nm by spectrophotometry Regulated area: Tests |
C.1.1/MO/52 (ČSN 75 7360) | ||
| 22 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of ammonium ions by spectrophotometry using the Gallery automatic analyser and calculation of ammonium nitrogen Regulated area: Tests |
C.1.1/MO/80 (Postup firmy Thermo Fisher Scientific; ČSN ISO 7150-1; ČSN EN ISO 15923-1) | ||
| 23 | Drinking water, ground water, surface water, raw water and process water | Determination of nitrites by spectrophotometry using the Gallery automatic analyser and calculation of nitrite nitrogen Regulated area: Tests |
C.1.1/MO/81 (Postup firmy Thermo Fisher Scientific; ČSN EN 26777; ČSN EN ISO 15923-1) | ||
| 24 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of the sum of nitrate and nitrite nitrogen (TON) after reduction with hydrazine by spectrophotometry using the Gallery automatic analyser and calculation of nitrates and nitrate nitrogen Regulated area: Tests |
C.1.1/MO/82 (Postup firmy Thermo Fisher Scientific; EPA Method 353.1; ČSN EN ISO 15923-1) | ||
| 25 | Drinking water, ground water, surface water, raw water, hot water and process water | Determination of orthophosphates by spectrophotometry with ammonium molybdate using the Gallery automatic analyser and calculation of phosphate phosphorus Regulated area: Tests |
C.1.1/MO/83 (Postup firmy Thermo Fisher Scientific; ČSN EN ISO 6878, čl. 4; ČSN EN ISO 15923-1) | ||
| 26 | Waste water, drinking water, ground water, surface water, raw water and process water | Determination of chlorides by spectrophotometry using the Gallery automatic analyser Regulated area: Tests |
C.1.1/MO/84 (Postup firmy Thermo Fisher Scientific; ČSN EN ISO 15682; EPA Method 325.2; ČSN EN ISO 15923-1) | ||
| 27 | Waste water, drinking water, ground water, surface water, raw water and process water | Determination of sulphates by turbidimetry using the Gallery automatic analyser Regulated area: Tests |
C.1.1/MO/85 (Postup firmy Thermo Fisher Scientific; EPA Method 375.4; ČSN EN ISO 15923-1) | ||
| 28 | Drinking water, ground water, surface water and raw water | Determination of fluorides by spectrophotometry using the Gallery automatic analyser Regulated area: Tests |
C.1.1/MO/86 (Postup firmy Thermo Fisher Scientific; EPA Method 340.3) | ||
| 29 | Drinking water, ground water, surface water, raw water and bathing water | Determination of oxidation-reduction potential (ORP) by potentiometry Regulated area: Tests |
C.1.1/MO/63 (ČSN 75 7367) | ||
| 30 | Drinking water, hot water and bathing water | Determination of free and total chlorine by spectrophotometry using a HACH kit and calculation of combined chlorine Regulated area: Tests |
C.1.1/MO/40 (Metodika firmy HACH; ČSN EN ISO 7393-2) | ||
| 31 | Waste water, drinking water, ground water, surface water, raw water, hot water and bathing water | Determination of temperature Regulated area: Tests |
C.1.1/MO/41 (ČSN 75 7342) | ||
| 32 | Waste water, ground water, surface water and raw water | Determination of oxygen by electrochemical method Regulated area: Tests |
C.1.1/MO/60 (ČSN EN ISO 5814) | ||
| 33 | Bathing water | Sensory determination of transparency Regulated area: Tests |
C.1.1/MO/97 (ČSN 75 7340; ČSN EN ISO 7027-2 čl. 5.2.1.1.) | ||
| 34 | Waste water, ground water, surface water, raw water and process water | Determination of dissolved oxygen by luminescence method Regulated area: Tests |
C.1.1/MO/71 (Metodika firmy HACH; ČSN ISO 17289) | ||
| 35 | Waste water, ground water, surface water and raw water | Determination of biochemical oxygen demand after n days (BODn) by luminescence Regulated area: Tests |
C.1.1/MO/96 (ČSN EN ISO 5815-1; ČSN ISO 17289) | ||
| 36 | Waste water, ground water, surface water, raw water and process water | Determination of suspended solids by gravimetry – filtration through glass fibre filters Regulated area: Tests |
C.1.1/MO/4 (ČSN EN 872) | ||
| 37 | Waste water, ground water, surface water, raw water and liquid waste | Determination of total phosphorus by spectrophotometry with ammonium molybdate Regulated area: Tests |
C.1.1/MO/5a (ČSN EN ISO 6878, čl. 7) | ||
| 38 | Waste water and liquid waste | Determination of dissolved solids (RL) and residue on ignition (RAS) by gravimetry Regulated area: Tests |
C.1.1/MO/6 (ČSN 75 7346; ČSN 75 7347) | ||
| 39 | Sludge | Determination of pH by potentiometry Regulated area: Tests |
C.1.1/MO/89 (ČSN EN ISO 10390) | ||
| 40 | Waste water, ground water, surface water, raw water and liquid waste | Determination of total nitrogen by spectrophotometry using a HACH kit Regulated area: Tests |
C.1.1/MO/38 (Metodika firmy HACH) | ||
| 41 | Sludge and liquid waste | Determination of dry matter (total solids) and loss on ignition by gravimetry Regulated area: Tests |
C.1.1/MO/56 (ČSN EN 12879:2001; ČSN EN 12880) | ||
| 42 | Sludge | Determination of Kjeldahl nitrogen by titration after mineralization and distillation Regulated area: Tests |
C.1.1/MO/57 (ČSN EN 13342) | ||
| 43 | Waste water, ground water, surface water, raw water and process water | Determination of anionic surfactants by spectrophotometry using a HACH kit Regulated area: Tests |
C.1.1/MO/79 (Metodika firmy HACH; ČSN EN 903) | ||
| 44 | Waste water, ground water, surface water, raw water and liquid waste | Determination of chemical oxygen demand by dichromate (CODCr) by spectrophotometry using a HACH kit Regulated area: Tests |
C.1.1/MO/87 (ČSN ISO 15705; Metodika firmy HACH) | ||
| 45 | Process chemicals | Determination of free (active) chlorine by spectrophotometry using a HACH kit Regulated area: Tests |
C.1.1/MO/103 (Metodika firmy HACH; ČSN EN ISO 7383-2; ČSN EN 901) | ||
| 46 | Waste water | Determination of ammonium ions by continuous flow analysis with spectrophotometric detection and calculation of ammonium nitrogen and total inorganic nitrogen Regulated area: Tests |
C.1.1/MO/94 (ČSN EN ISO 11732; Metodika firmy Skalar) | ||
| 47 | Waste water | Determination of nitrites and nitrates by continuous flow analysis with spectrophotometric detection and calculation of nitrogen forms Regulated area: Tests |
C.1.1/MO/95 (ČSN EN ISO 13395; Metodika firmy Skalar) | ||
| 48 | Waste water, ground water, surface water, raw water and liquid waste | Determination of chemical oxygen demand by dichromate (CODCr) by spectrophotometry using a HACH kit – method with a Skalar robotic analyser Regulated area: Tests |
C.1.1/MO/98 (Metodika firmy HACH; ČSN ISO 15705; Metodika firmy Skalar) | ||
| 49 | Waste water, drinking water, ground water, surface water, raw water, process water, aqueous leachate, sludge, liquid waste, waste and sediments | Determination of mercury by AMA 254 analyser Regulated area: Tests |
C.1.1/MO/28 (ČSN 75 7440; Manuál firmy Altec) | ||
| 50 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of selected anions by liquid ion chromatography and calculation of the sum of chlorites and chlorates bromates nitrates nitrites fluorides phosphates chlorates chlorides chlorites sulphates Regulated area: Tests |
C.1.1/MO/100 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061) | ||
| 51 | Process chemicals | Determination of chlorites, chlorates and bromates by liquid ion chromatography Regulated area: Tests |
C.1.1/MO/102 (ČSN EN ISO 10304-4; ČSN EN ISO 15061; ČSN EN 901) | ||
| 52 | Waste water, drinking water, ground water, surface water, raw water, process water, hot water, bathing water and liquid waste | Determination of selected elements by ICP-OES and calculation of the sum of calcium and magnesium aluminium boron barium beryllium calcium cadmium cobalt chromium copper iron magnesium manganese nickel lead vanadium zinc phosphorus Regulated area: Tests |
C.1.1/MO/77 (ČSN EN ISO 11885; ČSN EN ISO 15587-1; ČSN EN ISO 15587-2) | ||
| 53 | Sludge, waste and sediments | Determination of selected elements by ICP-OES arsenic barium beryllium calcium cadmium cobalt chromium copper potassium magnesium molybdenum nickel lead vanadium zinc phosphorus Regulated area: Tests |
C.1.1/MO/78 (ČSN EN ISO 11885; ČSN EN 16173; ČSN EN ISO 54321) | ||
| 54 | Waste water, drinking water, ground water, surface water, raw water, process water, hot water, bathing water, aqueous leachate and liquid waste | Determination of selected elements by ICP-MS and calculation of the sum of calcium and magnesium aluminium boron barium beryllium potassium sodium arsenic selenium antimony molybdenum silver uranium calcium cadmium cobalt chromium copper iron magnesium manganese nickel lead vanadium zinc phosphorus Regulated area: Tests |
C.1.1/MO/92 (ČSN EN ISO 17294-2; ČSN EN ISO 15587-1; ČSN EN ISO 15587-2) | ||
| 55 | Sludge, waste and sediments | Determination of selected elements by ICP-MS barium beryllium cobalt potassium arsenic calcium cadmium chromium copper magnesium nickel molybdenum vanadium lead zinc phosphorus Regulated area: Tests |
C.1.1/MO/93 (ČSN EN ISO 17294-2; ČSN EN ISO 16173; ČSN EN ISO 54321; Manuál firmy Milestone) | ||
| 56 | Waste water, drinking water, ground water, surface water, raw water, hot water, bathing water and aqueous leachate | Determination of total organic carbon (TOC), non-purgeable organic carbon (NPOC) and dissolved organic carbon (DOC) by high-temperature decomposition with IR detection Regulated area: Tests |
C.1.1/MO/42 (ČSN EN 1484) | ||
| 57 | Drinking water, ground water, surface water, raw water and hot water | Determination of volatile organic compounds (VOC) by Purge & Trap gas chromatography and GC/FID+ECD and calculation of the sum of trihalomethanes tetrachloromethane 1,2-dichloroethane trichloroethene bromodichloromethane tetrachloroethene dibromochloromethane tribromomethane (bromoform) trichloromethane (chloroform) benzene toluene chlorobenzene ethylbenzene m,p-xylene o-xylene Regulated area: Tests |
C.1.1/MO/49 (EPA Method 502.2) | ||
| 58 | Drinking water, ground water, surface water and raw water | Determination of selected organochlorine pesticides (OCP) by GC/ECD and calculation of the sum of pesticide substances hexachlorobenzene lindane heptachlor aldrin p,p-DDE dieldrin p,p-DDD methoxychlor p,p-DDT Regulated area: Tests |
C.1.1/MO/54 (EPA Method 505) | ||
| 59 | Ground water, surface water, raw water and waste water | Determination of hydrocarbons C10 – C40 (non-polar extractable substances NELGC) by GC/FID after solvent extraction Regulated area: Tests |
C.1.1/MO/58 (ČSN EN ISO 9377-2) | ||
| 60 | Waste water, ground water, surface water and raw water | Determination of extractable substances by gravimetry Regulated area: Tests |
C.1.1/MO/59 (ČSN 75 7508) | ||
| 61 | Sludge, waste and sediments | Determination of volatile organic compounds (VOC) by Purge & Trap and GC/FID and calculation of the sum of BTEX and BTX benzene toluene ethylbenzene m,p-xylene o-xylene Regulated area: Tests |
C.1.1/MO/72 (EPA Method 502.2; DIN ISO 15009) | ||
| 62 | Sludge, waste and sediments | Determination of hydrocarbons C10 – C40 by GC/FID after solvent extraction Regulated area: Tests |
C.1.1/MO/73 (ČSN EN 14039) | ||
| 63 | Sludge, waste and sediments | Determination of total organic carbon (TOC) by high-temperature decomposition with IR detection Regulated area: Tests |
C.1.1/MO/74 (ČSN EN 13137:2002; ČSN EN 15936) | ||
| 64 | Sludge, waste and sediments | Determination of selected polychlorinated biphenyls (PCB) by GC/ECD after solvent extraction and calculation of the sum of PCB PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 Regulated area: Tests |
C.1.1/MO/75 (ČSN EN 17322) | ||
| 65 | Waste and sediments | Determination of dry matter in waste by gravimetry Regulated area: Tests |
C.1.1/MO/76 (ČSN EN 14346:2007) | ||
| 66 | Drinking water, ground water, surface water, raw water and process water | Determination of selected analytes by LC/MS and calculation of the sum of selected substances acetochlor alachlor atrazine desethylatrazine cyanazine desmetryn diazinon dimethoate hexazinone chlorfenvinphos metazachlor metolachlor prometryn propachlor propazine simazine terbutryn terbuthylazine desethylterbuthylazine bromoacetic acid bromochloroacetic acid bromodichloroacetic acid chloroacetic acid dibromoacetic acid dibromochloroacetic acid dichloroacetic acid tribromoacetic acid trichloroacetic acid Regulated area: Tests |
C.1.1/MO/99 (EPA Method 536; ČSN ISO 21676; Metodika firmy Bruker) | ||
| 67 | Waste water, drinking water, ground water, surface water, raw water, process water, aqueous leachate and liquid waste | Determination of phenols by continuous flow analysis (CFA) Regulated area: Tests |
C.1.1/MO/104 (ČSN EN ISO 14402; Metodika firmy Skalar) | ||
| 68 | Waste water, drinking water, ground water, surface water, raw water and process water | Determination of total cyanides by continuous flow analysis (CFA) Regulated area: Tests |
C.1.1/MO/105 (ČSN EN ISO 14403-2; Metodika firmy Skalar) | ||
| 69 | Waste water | Determination of free cyanides by continuous flow analysis (CFA) Regulated area: Tests |
C.1.1/MO/107 (ČSN EN ISO 14403-2; Metodika firmy Skalar) | ||
| 70 | Waste water, drinking water, ground water, surface water, raw water, process water and liquid waste | Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC-FLD and calculation of the sum of PAH benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene benzo(ghi)perylene fluoranthene indeno(cd)pyrene Regulated area: Tests |
C.1.1/MO/106 (ČSN EN ISO 17993) | ||
| 71 | Sludge, waste and sediments | Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC-FLD after QuEChERS extraction and calculation of the sum of PAH naphthalene phenanthrene anthracene fluoranthene pyrene benzo(a)anthracene chrysene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene benzo(ghi)perylene indeno(cd)pyrene Regulated area: Tests |
C.1.1/MO/108 (ČSN EN ISO 17503) | ||
| 72 | Drinking water, raw water, process water and hot water | Sampling of drinking, raw, process and hot water Regulated area: Sampling |
C.2.1/ÚKJ/1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN ISO 5667-21; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.) | ||
| 73 | Waste water | Sampling of waste water (manually and by automatic sampler) Regulated area: Sampling |
C.2.1/ÚKJ/2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) | ||
| 74 | Sludge | Sampling of sludge from wastewater and water treatment plants Regulated area: Sampling |
C.2.1/ÚKJ/3 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ČSN EN 16179) | ||
| 75 | Bathing water | Sampling of bathing water Regulated area: Sampling |
C.2.1/ÚKJ/4 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 238/2011 Sb.) | ||
| 76 | Waste | Sampling of solid waste Regulated area: Sampling |
C.2.1/ÚKJ/5 (ČSN EN ISO 5667-15; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008); Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006)) | ||
| 77 | Sediment | Sampling of sediments Regulated area: Sampling |
C.2.1/ÚKJ/7 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-15; ČSN ISO 5667-12; Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006)) | ||
| 78 | Liquid waste | Sampling of liquid waste Regulated area: Sampling |
C.2.1/ÚKJ/8 (TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; ČSN EN 14899; ČSN EN ISO 5667-14; ČSN 01 5112; Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008)) | ||
| Laboratory Centre Liberec, Laboratory Liberec (P2A) | |||||
| 79 | Sludge | Determination of indicator micro-organisms – enterococci, thermotolerant coliform bacteria, Salmonella – by culture Regulated area: Tests |
C.1.1/LB/12 (AHEM č.1/2008, Státní zdravotní ústav v Praze) | ||
| 80 | Drinking water, ground water, surface water, raw water, process water, hot water and bathing water | Determination of Escherichia coli and coliform bacteria by the most probable number method Regulated area: Tests |
C.1.1/LB/13 (ČSN EN ISO 9308-2) | ||
| 81 | Hot water and bathing water | Determination of Legionella by direct membrane filtration Regulated area: Tests |
C.1.1/LB/14 (ČSN EN ISO 11731) | ||
| 82 | Ground water, surface water, raw water and bathing water | Determination of thermotolerant coliform bacteria by membrane filtration Regulated area: Tests |
C.1.1/LB/4 (ČSN 75 7835) | ||
| 83 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of intestinal enterococci by membrane filtration Regulated area: Tests |
C.1.1/LB/5 (ČSN EN ISO 7899-2) | ||
| 84 | Drinking water, ground water, surface water, raw water and process water | Biological analysis – determination of the microscopic picture Regulated area: Tests |
C.1.1/LB/11a (ČSN 75 7712) | ||
| 85 | Drinking water, ground water, surface water, raw water and process water | Biological analysis – microscopic determination of abioseston Regulated area: Tests |
C.1.1/LB/11b (ČSN 75 7713) | ||
| 86 | Drinking water, ground water, surface water, raw water and process water | Determination of Clostridium perfringens by membrane filtration Regulated area: Tests |
C.1.1/LB/8 (ČSN EN ISO 14189) | ||
| 87 | Drinking water, ground water, surface water, raw water, process water, hot water and bathing water | Enumeration of culturable micro-organisms by culture at 22 °C and 36 °C Regulated area: Tests |
C.1.1/LB/7 (ČSN EN ISO 6222) | ||
| 88 | Drinking water, ground water, surface water, raw water, process water, hot water and bathing water | Determination of Escherichia coli and coliform bacteria by membrane filtration Regulated area: Tests |
C.1.1/LB/1 (ČSN EN ISO 9308-1) | ||
| 89 | Hot water and bathing water | Determination of Pseudomonas aeruginosa by membrane filtration Regulated area: Tests |
C.1.1/LB/9 (ČSN EN ISO 16266) | ||
| 90 | Hot water and bathing water | Determination of coagulase-positive staphylococci by membrane filtration Regulated area: Tests |
C.1.1/LB/10 (ČSN EN ISO 6888-1) | ||
| 91 | Waste water, drinking water, ground water, surface water, raw water, process water, hot water and bathing water | Determination of pH by potentiometry Regulated area: Tests |
C.1.1/LB/21a (ČSN ISO 10523) | ||
| 92 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of electrical conductivity by conductometry Regulated area: Tests |
C.1.1/LB/22 (ČSN EN 27 888) | ||
| 93 | Drinking water, ground water, surface water, raw water and process water | Determination of acid neutralizing capacity (KNK4,5) by acid-base titration Regulated area: Tests |
C.1.1/LB/23 (ČSN EN ISO 9963-1) | ||
| 94 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of chlorides by argentometric titration Regulated area: Tests |
C.1.1/LB/24 (ČSN ISO 9297) | ||
| 95 | Drinking water, ground water, surface water, raw water, process water, hot water and bathing water | Determination of chemical oxygen demand by permanganate (CODMn) by manganometric titration Regulated area: Tests |
C.1.1/LB/25 (ČSN EN ISO 8467) | ||
| 96 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of nitrates by UV spectrophotometry and calculation of nitrate nitrogen Regulated area: Tests |
C.1.1/LB/26 (Vodní hospodářství 2/1988 B) | ||
| 97 | Drinking water, ground water, surface water, raw water and process water | Determination of nitrites by spectrophotometry and calculation of nitrite nitrogen Regulated area: Tests |
C.1.1/LB/28 – A (ČSN EN 26777) | ||
| 98 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of ammonium ions by spectrophotometry and calculation of ammonium nitrogen Regulated area: Tests |
C.1.1/LB/29 – A (ČSN ISO 7150-1) | ||
| 99 | Drinking water, ground water, surface water, raw water and process water | Determination of aluminium by spectrophotometry with pyrocatechol violet Regulated area: Tests |
C.1.1/LB/30 (ČSN ISO 10566) | ||
| 100 | Waste water, drinking water, ground water, surface water, raw water and process water | Determination of sulphates by turbidimetry with barium chloride Regulated area: Tests |
C.1.1/LB/31 (Vodní hospodářství 7/1984 B) | ||
| 101 | Waste water, drinking water, ground water, surface water, raw water, process water, aqueous leachate, sludge and liquid waste | Determination of fluorides by potentiometry (ISE) Regulated area: Tests |
C.1.1/LB/32 (ČSN ISO 10359-1) | ||
| 102 | Drinking water, ground water, surface water, raw water, process water, hot water and bathing water | Determination of colour by spectrophotometry Regulated area: Tests |
C.1.1/LB/103 (ČSN EN ISO 7887) | ||
| 103 | Drinking water, ground water, surface water, raw water and hot water | Sensory determination of odour Regulated area: Tests |
C.1.1/LB/108 (ČSN 75 7340) | ||
| 104 | Drinking water | Sensory determination of taste Regulated area: Tests |
C.1.1/LB/38 (ČSN 75 7340) | ||
| 105 | Waste water, ground water, surface water, raw water, process water and liquid waste | Determination of adsorbable organically bound halogens (AOX) by microcoulometry Regulated area: Tests |
C.1.1/LB/107a (ČSN EN ISO 9562; TNI 75 7531) | ||
| 106 | Sludge, waste and sediments | Determination of adsorbable organically bound halogens (AOX) by microcoulometry Regulated area: Tests |
C.1.1/LB/107b (ČSN EN 16166) | ||
| 107 | Waste water, drinking water, ground water, surface water, raw water, process water, hot water, aqueous leachate, sludge, waste, liquid waste and sediments | Determination of mercury by AMA 254 analyser Regulated area: Tests |
C.1.1/LB/51 (ČSN 75 7440; Metodika firmy Altec) | ||
| 108 | Drinking water, ground water, surface water, raw water, process water and hot water | Determination of calcium and magnesium by flame AAS and calculation of the sum of calcium and magnesium Regulated area: Tests |
C.1.1/LB/52 (ČSN ISO 7980) | ||
| 109 | Sludge, waste and sediments | Determination of total dry matter by moisture analyser Regulated area: Tests |
C.1.1/LB/94 (Metodika firmy OHAUS) | ||
| 110 | Drinking water, process water and bathing water | Determination of ozone by spectrophotometry using a HACH kit Regulated area: Tests |
C.1.1/LB/128 (Metodika firmy HACH) | ||
| 111 | Waste water, drinking water, ground water, surface water, raw water, process water and hot water | Determination of iron and manganese by flame AAS Regulated area: Tests |
C.1.1/LB/53 (ČSN 75 7385) | ||
| 112 | Waste | Determination of extractable organically bound halogens (EOX) by extraction Regulated area: Tests |
C.1.1/LB/48 (DIN 38414-17) | ||
| 113 | Drinking water, ground water, surface water, raw water, process water, hot water and bathing water | Determination of turbidity by nephelometry Regulated area: Tests |
C.1.1/LB/42 (ČSN EN ISO 7027-1) | ||
| 114 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of absorbance at 254 nm by spectrophotometry Regulated area: Tests |
C.1.1/LB/101 (ČSN 75 7360) | ||
| 115 | Drinking water, ground water, surface water, raw water and process water | Determination of sulphates (SO42-) by turbidimetry using the BluVision automatic analyser Regulated area: Tests |
C.1.1/LB/54 (Metodika firmy Skalar; ČSN EN ISO 15923-1) | ||
| 116 | Drinking water, ground water, surface water, raw water and process water | Determination of nitrites by spectrophotometry and calculation of nitrite nitrogen using the BluVision automatic analyser Regulated area: Tests |
C.1.1/LB/56 (Metodika firmy Skalar; ČSN EN ISO 15923-1) | ||
| 117 | Drinking water, ground water, surface water, raw water and process water | Determination of ammonium ions by spectrophotometry and calculation of ammonium nitrogen using the BluVision automatic analyser Regulated area: Tests |
C.1.1/LB/57 (Metodika firmy Skalar; ČSN EN ISO 15923-1) | ||
| 118 | Drinking water, ground water, surface water, raw water, process water and hot water | Determination of calcium by spectrophotometry using the BluVision automatic analyser and calculation of the sum of calcium and magnesium Regulated area: Tests |
C.1.1/LB/59 (Metodika firmy Skalar; ISO/TS 15923-2) | ||
| 119 | Drinking water, ground water, surface water, raw water, process water, hot water and bathing water | Determination of free and total chlorine by spectrophotometry using a HACH kit and calculation of combined chlorine Regulated area: Tests |
C.1.1/LB/104 (Metodika firmy HACH; ČSN EN ISO 7393-2) | ||
| 120 | Waste water, drinking water, ground water, surface water, raw water, process water, hot water and bathing water | Determination of temperature Regulated area: Tests |
C.1.1/LB/105 (ČSN 75 7342) | ||
| 121 | Waste water, process water, aqueous leachate and liquid waste | Determination of chlorides by microcoulometric titration Regulated area: Tests |
C.1.1/LB/122 (Metodika firmy LABTECH; ČSN ISO 9297) | ||
| 122 | Drinking water, ground water, surface water, raw water, process water and hot water | Determination of magnesium by spectrophotometry using the BluVision automatic analyser Regulated area: Tests |
C.1.1/LB/60 (Metodika firmy Skalar; ISO/TS 15923-2) | ||
| 123 | Drinking water, ground water, surface water, raw water, process water and hot water | Determination of iron by spectrophotometry using the BluVision automatic analyser Regulated area: Tests |
C.1.1/LB/63 (Metodika firmy Skalar; ISO/TS 15923-2) | ||
| 124 | Waste water, ground water, surface water, raw water and process water | Determination of oxygen by electrochemical method Regulated area: Tests |
C.1.1/LB/109 (ČSN EN ISO 5814) | ||
| 125 | Bathing water | Determination of oxidation-reduction potential (ORP) by potentiometry Regulated area: Tests |
C.1.1/LB/125 (ČSN 75 7367) | ||
| 126 | Bathing water | Sensory determination of transparency Regulated area: Tests |
C.1.1/LB/66 (ČSN 75 7340; ČSN EN ISO 7027-2, čl. 5.2.1.1.) | ||
| 127 | Waste water, drinking water, ground water, surface water, raw water, process water, bathing water and aqueous leachate | Determination of total organic carbon (TOC), non-purgeable organic carbon (NPOC), inorganic carbon (TIC), total carbon (TC) and dissolved organic carbon (DOC) by high-temperature decomposition with IR detection Regulated area: Tests |
C.1.1/LB/50 (ČSN EN 1484) | ||
| 128 | Drinking water, ground water, surface water, raw water, process water and hot water | Determination of manganese by spectrophotometry using the BluVision automatic analyser Regulated area: Tests |
C.1.1/LB/64 (Metodika firmy Skalar; ISO/TS 15923-2) | ||
| 129 | Drinking water, ground water, surface water, raw water and hot water | Determination of phosphates by spectrophotometry using the BluVision automatic analyser Regulated area: Tests |
C.1.1/LB/65 (Metodika firmy Skalar; ČSN EN ISO 15923-1) | ||
| 130 | Drinking water, ground water, surface water and raw water | Determination of humic substances by spectrophotometry after extraction Regulated area: Tests |
C.1.1/LB/110 (ČSN 75 7536) | ||
| 131 | Drinking water, ground water, surface water, raw water and process water | Determination of chlorides by spectrophotometry using the BluVision automatic analyser Regulated area: Tests |
C.1.1/LB/95 (Metodika firmy Skalar; ČSN EN ISO 15923-1) | ||
| 132 | Drinking water, raw water, process water and hot water | Sampling of drinking, raw, process and hot water Regulated area: Sampling |
C.2.1/ÚKJ/1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN ISO 5667-21; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.) | ||
| 133 | Bathing water | Sampling of bathing water Regulated area: Sampling |
C.2.1/ÚKJ/4 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 238/2011 Sb.) | ||
| 134 | Surface water | Sampling of surface water Regulated area: Sampling |
C.2.1/ÚKJ/6 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16) | ||
| Laboratory Centre Liberec, WWTP Laboratory Liberec (P2B) | |||||
| 135 | Waste water, drinking water, raw water, surface water, ground water, process water, hot water, bathing water and liquid waste | Determination of pH by potentiometry Regulated area: Tests |
C.1.1/LB/21a (ČSN ISO 10523) | ||
| 136 | Aqueous leachate | Determination of pH by potentiometry Regulated area: Tests |
C.1.1/LB/46b (ČSN ISO 10523) | ||
| 137 | Sludge | Determination of pH by potentiometry Regulated area: Tests |
C.1.1/LB/46c (ČSN ISO 10523; ČSN EN 12176:2014) | ||
| 138 | Waste water and process water | Determination of nitrate nitrogen by spectrophotometry with sulfosalicylic acid Regulated area: Tests |
C.1.1/LB/27 (ČSN ISO 7890-3) | ||
| 139 | Waste water and process water | Determination of nitrite nitrogen by spectrophotometry Regulated area: Tests |
C.1.1/LB/28 – B (ČSN EN 26777) | ||
| 140 | Waste water, process water and liquid waste | Determination of ammonium nitrogen by spectrophotometry Regulated area: Tests |
C.1.1/LB/29 – B (ČSN ISO 7150-1) | ||
| 141 | Waste water, ground water, surface water, raw water, process water and liquid waste | Determination of chemical oxygen demand by dichromate (CODCr) by spectrophotometry using a HACH kit Regulated area: Tests |
C.1.1/LB/33 (ČSN ISO 15705; Metodika firmy HACH) | ||
| 142 | Waste water, drinking water, ground water, surface water, raw water, process water, hot water and liquid waste | Determination of orthophosphates and total phosphorus by spectrophotometry with ammonium molybdate and calculation of phosphorus pentoxide from total phosphorus Regulated area: Tests |
C.1.1/LB/34 (ČSN EN ISO 6878, čl. 4 a čl. 7) | ||
| 143 | Waste water, ground water, surface water, raw water and process water | Determination of suspended solids by gravimetry – filtration through glass fibre filters Regulated area: Tests |
C.1.1/LB/35 (ČSN EN 872) | ||
| 144 | Waste water, ground water, surface water, raw water, aqueous leachate and liquid waste | Determination of dissolved solids (RL) and ignited dissolved solids (RAS) by gravimetry Regulated area: Tests |
C.1.1/LB/36 (ČSN 75 7346; ČSN 75 7347; ČSN EN 15216) | ||
| 145 | Waste water, ground water, surface water, raw water, process water and liquid waste | Determination of biochemical oxygen demand after n days (BODn) by electrochemical method Regulated area: Tests |
C.1.1/LB/62 (ČSN EN ISO 5815-1) | ||
| 146 | Waste water, ground water, surface water, raw water, process water and liquid waste | Determination of total nitrogen by spectrophotometry using a HACH kit and calculation of organic and inorganic nitrogen Regulated area: Tests |
C.1.1/LB/43 (Metodika firmy HACH; ČSN EN ISO 11905-1) | ||
| 147 | Waste water | Determination of anionic surfactants with methylene blue (MBAS) by spectrophotometry after extraction Regulated area: Tests |
C.1.1/LB/127 (ČSN EN 903) | ||
| 148 | Waste water | Determination of Kjeldahl nitrogen by titration after mineralization and distillation and calculation of total, organic and inorganic nitrogen Regulated area: Tests |
C.1.1/LB/37a (ČSN EN 13342; ČSN EN 25663) | ||
| 149 | Sludge | Determination of Kjeldahl nitrogen by titration after mineralization and distillation Regulated area: Tests |
C.1.1/LB/37b (ČSN EN 13342; ČSN EN 25663) | ||
| 150 | Waste water and process water | Determination of temperature Regulated area: Tests |
C.1.1/LB/105 (ČSN 75 7342) | ||
| 151 | Waste water and aqueous leachate | Determination of electrical conductivity by conductometry Regulated area: Tests |
C.1.1/LB/47 (ČSN EN 27888) | ||
| 152 | Waste water, sludge, waste, liquid waste and sediments | Determination of total dry matter (total solids), residue on ignition and loss on ignition by gravimetry Regulated area: Tests |
C.1.1/LB/93 (ČSN EN 12880; ČSN EN 15934; ČSN EN 15935) | ||
| 153 | Waste water and liquid waste | Determination of anionic surfactants by spectrophotometry using a HACH kit Regulated area: Tests |
C.1.1/LB/49 (Metodika firmy HACH; ČSN EN 903) | ||
| 154 | Waste water, ground water, surface water, raw water, process water and liquid waste | Determination of biochemical oxygen demand after n days (BODn) by luminescence Regulated area: Tests |
C.1.1/LB/61 (ČSN EN ISO 5815-1; ČSN ISO 17289) | ||
| 155 | Waste water | Sampling of waste water (manually and by automatic sampler) Regulated area: Sampling |
C.2.1/ÚKJ/2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) | ||
| 156 | Sludge | Sampling of sludge from wastewater and water treatment plants Regulated area: Sampling |
C.2.1/ÚKJ/3 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ČSN EN 16179) | ||
| 157 | Waste | Sampling of solid waste Regulated area: Sampling |
C.2.1/ÚKJ/5 (ČSN EN ISO 5667-15; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008); Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006)) | ||
| 158 | Sediment | Sampling of sediments Regulated area: Sampling |
C.2.1/ÚKJ/7 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-15; ČSN ISO 5667-12; Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006)) | ||
| 159 | Liquid waste | Sampling of liquid waste Regulated area: Sampling |
C.2.1/ÚKJ/8 (TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; ČSN EN 14899; ČSN EN ISO 5667-14; ČSN 01 5112; Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008)) | ||
| Laboratory Centre Ústí nad Labem, Water Treatment Plant Laboratory Velké Žernoseky (P3A) | |||||
| 160 | Drinking water, ground water, surface water and raw water | Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration Regulated area: Tests |
C.1.1/UL/MB-8 (ČSN 75 7835) | ||
| 161 | Drinking water, ground water, surface water and raw water | Determination of intestinal enterococci by membrane filtration Regulated area: Tests |
C.1.1/UL/MB-4 (ČSN EN ISO 7899-2) | ||
| 162 | Drinking water, ground water, surface water, raw water, process water, hot water and bathing water | Determination of Escherichia coli and coliform bacteria by membrane filtration Regulated area: Tests |
C.1.1/UL/MB-13 (ČSN EN ISO 9308-1) | ||
| 163 | Drinking water, ground water, surface water, raw water, hot water, process water and bathing water | Enumeration of culturable micro-organisms by culture at 22 °C and 36 °C Regulated area: Tests |
C.1.1/UL/MB-6 (ČSN EN ISO 6222) | ||
| 164 | Drinking water, ground water, surface water and raw water | Determination of Clostridium perfringens by membrane filtration Regulated area: Tests |
C.1.1/UL/MB-14 (ČSN EN ISO 14189) | ||
| 165 | Drinking water, ground water, surface water, raw water, process water, hot water and bathing water | Determination of Escherichia coli and coliform bacteria by the most probable number method Regulated area: Tests |
C.1.1/UL/MB-9 (ČSN EN ISO 9308-2) | ||
| 166 | Drinking water, ground water, surface water, raw water and process water | Biological analysis – microscopic determination of living organisms and number of organisms Regulated area: Tests |
C.1.1/UL/BI-1A (ČSN 75 7712) | ||
| 167 | Drinking water, ground water, raw water and process water | Biological analysis – microscopic determination of abioseston Regulated area: Tests |
C.1.1/UL/BI-2A (ČSN 75 7713) | ||
| 168 | Bathing water | Determination of Pseudomonas aeruginosa by membrane filtration Regulated area: Tests |
C.1.1/UL/MB-10 (ČSN EN ISO 16266) | ||
| 169 | Bathing water | Determination of coagulase-positive staphylococci by membrane filtration Regulated area: Tests |
C.1.1/UL/MB-11 (ČSN EN ISO 6888-1) | ||
| 170 | Hot water and bathing water | Determination of Legionella by direct membrane filtration Regulated area: Tests |
C.1.1/UL/MB-12 (ČSN EN ISO 11731) | ||
| 171 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of pH by potentiometry Regulated area: Tests |
C.1.1/UL/4A (ČSN ISO 10523) | ||
| 172 | Drinking water, ground water, surface water, raw water and process water | Determination of chemical oxygen demand by permanganate (CODMn) by titration Regulated area: Tests |
C.1.1/UL/5A (ČSN EN ISO 8467) | ||
| 173 | Drinking water, ground water, surface water, raw water and process water | Determination of acid neutralizing capacity (KNK4,5) by acid-base titration Regulated area: Tests |
C.1.1/UL/10 (ČSN EN ISO 9963-1) | ||
| 174 | Drinking water, ground water, surface water, raw water and process water | Determination of iron by spectrophotometry with 1,10-phenanthroline Regulated area: Tests |
C.1.1/UL/12 (ČSN ISO 6332) | ||
| 175 | Drinking water, ground water, surface water, raw water and process water | Determination of dissolved solids by gravimetry Regulated area: Tests |
C.1.1/UL/13 (ČSN 75 7346) | ||
| 176 | Drinking water, ground water, surface water, raw water and process water | Determination of electrical conductivity by conductometry Regulated area: Tests |
C.1.1/UL/15 (ČSN EN 27888) | ||
| 177 | Drinking water, ground water, surface water, raw water and process water | Determination of manganese by spectrophotometry with formaldoxime Regulated area: Tests |
C.1.1/UL/16 (ČSN ISO 6333) | ||
| 178 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of turbidity by nephelometry Regulated area: Tests |
C.1.1/UL/61A (ČSN EN ISO 7027-1) | ||
| 179 | Drinking water, ground water, surface water and raw water | Sensory determination of odour and taste Regulated area: Tests |
C.1.1/UL/23 (ČSN 75 7340; ČSN EN 1622) | ||
| 180 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of free and total chlorine by spectrophotometry using a HACH kit and calculation of combined chlorine Regulated area: Tests |
C.1.1/UL/24 (Metodika firmy HACH; ČSN EN ISO 7393-2) | ||
| 181 | Waste water, drinking water, ground water, surface water, raw water, process water and bathing water | Determination of temperature Regulated area: Tests |
C.1.1/UL/25 (ČSN 757342) | ||
| 182 | Drinking water, ground water, surface water, raw water and process water | Determination of oxygen saturation by luminescence Regulated area: Tests |
C.1.1/UL/83 (Metodika firmy HACH; ČSN EN ISO 17289) | ||
| 183 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of absorbance at 254 nm by spectrophotometry Regulated area: Tests |
C.1.1/UL/63 (ČSN 75 7360) | ||
| 184 | Drinking water, ground water, surface water, raw water and process water | Determination of colour by spectrophotometry Regulated area: Tests |
C.1.1/UL/62 (ČSN EN ISO 7887) | ||
| 185 | Drinking water, ground water, surface water, raw water and process water | Determination of humic substances by spectrophotometry after extraction Regulated area: Tests |
C.1.1/UL/71A (ČSN 75 7536) | ||
| 186 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of nitrates by UV spectrophotometry Regulated area: Tests |
C.1.1/UL/72A (Vodní hospodářství č. 2/1988 – řada B) | ||
| 187 | Drinking water, ground water, surface water, raw water and process water | Determination of ozone by spectrophotometry using a HACH kit Regulated area: Tests |
C.1.1/UL/46 (Metodika firmy HACH) | ||
| 188 | Drinking water, raw water, ground water, surface water, process water and bathing water | Determination of oxidation-reduction potential (ORP) by potentiometry Regulated area: Tests |
C.1.1/UL/73 (ČSN 75 7367) | ||
| 189 | Bathing water | Sensory determination of transparency Regulated area: Tests |
C.1.1/UL/89 (ČSN 75 7340; ČSN EN ISO 7027-2, čl. 5.2.1.1) | ||
| 190 | Drinking water, ground water, surface water, raw water and process water | Determination of ammonium ions by spectrophotometry using the Gallery automatic analyser Regulated area: Tests |
C.1.1/UL/74 (Postup firmy Thermo Fisher Scientific; ČSN ISO 7150-1; ČSN EN ISO 15923-1) | ||
| 191 | Drinking water, ground water, surface water, raw water and process water | Determination of nitrites by spectrophotometry using the Gallery automatic analyser Regulated area: Tests |
C.1.1/UL/75 (Postup firmy Thermo Fisher Scientific; ČSN EN ISO 15923-1; ČSN EN 26777) | ||
| 192 | Drinking water, ground water, surface water, raw water and process water | Determination of nitrates by spectrophotometry using the Gallery automatic analyser Regulated area: Tests |
C.1.1/UL/76 (Postup firmy Thermo Fisher Scientific; ČSN EN ISO 15923-1; ČSN ISO 7890-3; EPA Method 353.1) | ||
| 193 | Drinking water, ground water, surface water, raw water and process water | Determination of chlorides by spectrophotometry using the Gallery automatic analyser Regulated area: Tests |
C.1.1/UL/77 (Postup firmy Thermo Fisher Scientific; ČSN EN ISO 15923-1; ČSN 75 7422) | ||
| 194 | Drinking water, ground water, surface water, raw water and process water | Determination of sulphates by spectrophotometry using the Gallery automatic analyser Regulated area: Tests |
C.1.1/UL/78 (Postup firmy Thermo Fisher Scientific; ČSN EN ISO 15923-1; EPA 375.4) | ||
| 195 | Drinking water, ground water, surface water, raw water and process water | Determination of orthophosphates by spectrophotometry with ammonium molybdate using the Gallery automatic analyser Regulated area: Tests |
C.1.1/UL/79 (Postup firmy Thermo Fisher Scientific; ČSN EN ISO 15923-1; ČSN EN ISO 6878, čl. 4) | ||
| 196 | Drinking water, ground water, surface water, raw water and process water | Determination of calcium by spectrophotometry using the Gallery automatic analyser and calculation of the sum of calcium and magnesium Regulated area: Tests |
C.1.1/UL/80 (Postup firmy Thermo Fisher Scientific) | ||
| 197 | Drinking water, ground water, surface water, raw water and process water | Determination of magnesium by spectrophotometry using the Gallery automatic analyser Regulated area: Tests |
C.1.1/UL/81 (Postup firmy Thermo Fisher Scientific) | ||
| 198 | Drinking water, ground water, surface water, raw water and process water | Determination of iron by spectrophotometry using the Gallery automatic analyser Regulated area: Tests |
C.1.1/UL/84 (Postup firmy Thermo Fisher Scientific; ČSN ISO 6332) | ||
| 199 | Drinking water, ground water, surface water, raw water and process water | Determination of aluminium by spectrophotometry using the Gallery automatic analyser Regulated area: Tests |
C.1.1/UL/85 (Postup firmy Thermo Fisher Scientific; ČSN ISO 10566) | ||
| 200 | Drinking water, ground water, surface water, raw water and process water | Determination of fluorides by spectrophotometry using the Gallery automatic analyser Regulated area: Tests |
C.1.1/UL/86 (Postup firmy Thermo Fisher Scientific) | ||
| 201 | Drinking water, ground water, surface water, raw water and process water | Determination of KNK4,5 by spectrophotometry using the Gallery automatic analyser Regulated area: Tests |
C.1.1/UL/87 (Postup firmy Thermo Fisher Scientific) | ||
| 202 | Drinking water, raw water, process water and hot water | Sampling of drinking, raw, process and hot water Regulated area: Sampling |
C.2.1/ÚKJ/1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN ISO 5667-21; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.) | ||
| 203 | Bathing water | Sampling of bathing water Regulated area: Sampling |
C.2.1/ÚKJ/4 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 238/2011 Sb.) | ||
| Laboratory Centre Ústí nad Labem, WWTP Laboratory Neštěmice (P3B) | |||||
| 204 | Waste water, ground water, surface water and raw water | Determination of ammonium ions by spectrophotometry and calculation of ammonium and inorganic nitrogen Regulated area: Tests |
C.1.1/UL/1B (ČSN ISO 7150-1) | ||
| 205 | Waste water and raw water | Determination of nitrates by spectrophotometry with sulfosalicylic acid and calculation of nitrate nitrogen Regulated area: Tests |
C.1.1/UL/2B (ČSN ISO 7890-3) | ||
| 206 | Waste water and raw water | Determination of nitrites by spectrophotometry and calculation of nitrite nitrogen Regulated area: Tests |
C.1.1/UL/3B (ČSN EN 26777) | ||
| 207 | Waste water, raw water and liquid waste | Determination of pH by potentiometry Regulated area: Tests |
C.1.1/UL/4B (ČSN ISO 10523) | ||
| 208 | Waste water, ground water, surface water and raw water | Determination of biochemical oxygen demand after n days (BODn) by luminescence Regulated area: Tests |
C.1.1/UL/88B (ČSN EN ISO 5815-1; ČSN ISO 17289) | ||
| 209 | Waste water, ground water, surface water, raw water and liquid waste | Determination of total phosphorus by spectrophotometry with ammonium molybdate Regulated area: Tests |
C.1.1/UL/7 (ČSN EN ISO 6878, čl. 7) | ||
| 210 | Waste water, ground water, surface water and raw water | Determination of suspended solids by gravimetry – filtration through glass fibre filters Regulated area: Tests |
C.1.1/UL/8 (ČSN EN 872) | ||
| 211 | Waste water, raw water and liquid waste | Determination of dissolved solids (RL) by gravimetry Regulated area: Tests |
C.1.1/UL/9 (ČSN 75 7346) | ||
| 212 | Waste water, ground water, surface water, raw water and liquid waste | Determination of total nitrogen by oxidative digestion with peroxodisulphate by spectrophotometry using a HACH kit and calculation of organic nitrogen Regulated area: Tests |
C.1.1/UL/26 (Metodika firmy HACH) | ||
| 213 | Waste water, drinking water, ground water, surface water, raw water, process water and bathing water | Determination of temperature Regulated area: Tests |
C.1.1/UL/25 (ČSN 75 7342) | ||
| 214 | Waste water and liquid waste | Determination of dissolved inorganic salts (RAS) by gravimetry Regulated area: Tests |
C.1.1/UL/68B (ČSN 75 7347) | ||
| 215 | Waste water | Determination of chlorides by titration Regulated area: Tests |
C.1.1/UL/14B (ČSN ISO 9297) | ||
| 216 | Waste water | Determination of sulphates by turbidimetry Regulated area: Tests |
C.1.1/UL/19B (ASTM D 516-88) | ||
| 217 | Sludge | Determination of pH by potentiometry Regulated area: Tests |
C.1.1/UL/57B (ČSN EN ISO 10390) | ||
| 218 | Sludge and liquid waste | Determination of dry matter (total solids) by gravimetry Regulated area: Tests |
C.1.1/UL/58B (ČSN EN 12880) | ||
| 219 | Sludge | Determination of loss on ignition by gravimetry Regulated area: Tests |
C.1.1/UL/59B (ČSN EN 12879:2001) | ||
| 220 | Waste water, ground water, surface water, raw water and liquid waste | Determination of chemical oxygen demand by dichromate (CODCr) by spectrophotometry using a HACH kit Regulated area: Tests |
C.1.1/UL/60B (ČSN ISO 15705; Metodika firmy HACH) | ||
| 221 | Waste water | Sampling of waste water (manually and by automatic sampler) Regulated area: Sampling |
C.2.1/ÚKJ/2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) | ||
| 222 | Sludge | Sampling of sludge from wastewater and water treatment plants Regulated area: Sampling |
C.2.1/ÚKJ/3 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ČSN EN 16179) | ||
| 223 | Waste | Sampling of solid waste Regulated area: Sampling |
C.2.1/ÚKJ/5 (ČSN EN ISO 5667-15; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008); Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006)) | ||
| 224 | Sediment | Sampling of sediments Regulated area: Sampling |
C.2.1/ÚKJ/7 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-15; ČSN ISO 5667-12; Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006)) | ||
| 225 | Liquid waste | Sampling of liquid waste Regulated area: Sampling |
C.2.1/ÚKJ/8 (TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; ČSN EN 14899; ČSN EN ISO 5667-14; ČSN 01 5112; Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008)) | ||
| Laboratory Centre Ústí nad Labem, Laboratory Děčín-Bynov (P3C) | |||||
| 226 | Drinking water, ground water, surface water and raw water | Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration Regulated area: Tests |
C.1.1/UL/MB-57 (ČSN 75 7835) | ||
| 227 | Drinking water, ground water, surface water and raw water | Determination of intestinal enterococci by membrane filtration Regulated area: Tests |
C.1.1/UL/MB-58 (ČSN EN ISO 7899-2) | ||
| 228 | Drinking water, ground water, surface water, raw water, process water, hot water and bathing water | Determination of Escherichia coli and coliform bacteria by membrane filtration Regulated area: Tests |
C.1.1/UL/MB-65 (ČSN EN ISO 9308-1) | ||
| 229 | Drinking water, ground water, surface water, raw water, hot water and bathing water | Enumeration of culturable micro-organisms by culture at 22 °C and 36 °C Regulated area: Tests |
C.1.1/UL/MB-60 (ČSN EN ISO 6222) | ||
| 230 | Drinking water, ground water, surface water and raw water | Determination of Clostridium perfringens by membrane filtration Regulated area: Tests |
C.1.1/UL/MB-66 (ČSN EN ISO 14189) | ||
| 231 | Drinking water, ground water, surface water, raw water, hot water, process water and bathing water | Determination of Escherichia coli and coliform bacteria by the most probable number method Regulated area: Tests |
C.1.1/UL/MB-62 (ČSN EN ISO 9308-2) | ||
| 232 | Drinking water, ground water, surface water and raw water | Biological analysis – microscopic determination of living organisms and number of organisms Regulated area: Tests |
C.1.1/UL/BI-1C (ČSN 75 7712) | ||
| 233 | Drinking water, ground water, surface water, raw water and process water | Biological analysis – microscopic determination of abioseston Regulated area: Tests |
C.1.1/UL/BI-2C (ČSN 75 7713) | ||
| 234 | Bathing water | Determination of Pseudomonas aeruginosa by membrane filtration Regulated area: Tests |
C.1.1/UL/MB-63 (ČSN EN ISO 16266) | ||
| 235 | Bathing water | Determination of coagulase-positive staphylococci by membrane filtration Regulated area: Tests |
C.1.1/UL/MB-64 (ČSN EN ISO 6888-1) | ||
| 236 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of ammonium ions by spectrophotometry Regulated area: Tests |
C.1.1/UL/27 (ČSN ISO 7150-1) | ||
| 237 | Drinking water, ground water, surface water, raw water and process water | Determination of nitrites by spectrophotometry Regulated area: Tests |
C.1.1/UL/29 (ČSN EN 26777) | ||
| 238 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of pH by potentiometry Regulated area: Tests |
C.1.1/UL/30 (ČSN ISO 10523) | ||
| 239 | Drinking water, ground water, surface water, raw water and process water | Determination of chemical oxygen demand by permanganate (CODMn) by manganometric titration Regulated area: Tests |
C.1.1/UL/31 (ČSN EN ISO 8467) | ||
| 240 | Drinking water, ground water, surface water, raw water and process water | Determination of acid neutralizing capacity (KNK4,5) by acid-base titration Regulated area: Tests |
C.1.1/UL/32 (ČSN EN ISO 9963-1) | ||
| 241 | Drinking water, ground water, surface water, raw water and process water | Determination of aluminium by spectrophotometry with pyrocatechol violet Regulated area: Tests |
C.1.1/UL/33 (ČSN ISO 10566) | ||
| 242 | Drinking water, ground water, surface water, raw water and process water | Determination of iron by spectrophotometry with 1,10-phenanthroline Regulated area: Tests |
C.1.1/UL/34 (ČSN ISO 6332) | ||
| 243 | Drinking water, ground water, surface water, raw water and process water | Determination of dissolved solids by gravimetry Regulated area: Tests |
C.1.1/UL/35 (ČSN 75 7346) | ||
| 244 | Drinking water, ground water, surface water, raw water and process water | Determination of chlorides by mercurimetric titration Regulated area: Tests |
C.1.1/UL/36 (AOAC 973.51) | ||
| 245 | Drinking water, ground water, surface water, raw water and process water | Determination of electrical conductivity by conductometry Regulated area: Tests |
C.1.1/UL/37 (ČSN EN 27888) | ||
| 246 | Drinking water, ground water, surface water, raw water and process water | Determination of manganese by spectrophotometry with formaldoxime Regulated area: Tests |
C.1.1/UL/38 (ČSN ISO 6333) | ||
| 247 | Drinking water, ground water, surface water, raw water and process water | Determination of the sum of calcium and magnesium by EDTA titration and calculation of magnesium Regulated area: Tests |
C.1.1/UL/39 (ČSN ISO 6059) | ||
| 248 | Drinking water, ground water, surface water, raw water and process water | Determination of calcium by EDTA titration Regulated area: Tests |
C.1.1/UL/40 (ČSN ISO 6058) | ||
| 249 | Drinking water, ground water, surface water, raw water and process water | Determination of fluorides by electrochemical method Regulated area: Tests |
C.1.1/UL/42 (ČSN ISO 10359-1) | ||
| 250 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of turbidity by nephelometry Regulated area: Tests |
C.1.1/UL/61C (ČSN EN ISO 7027-1) | ||
| 251 | Drinking water, ground water, surface water and raw water | Sensory determination of odour and taste Regulated area: Tests |
C.1.1/UL/44 (ČSN 75 7340; ČSN EN 1622) | ||
| 252 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of free and total chlorine by spectrophotometry using a HACH kit and calculation of combined chlorine Regulated area: Tests |
C.1.1/UL/24 (Metodika firmy HACH; ČSN EN ISO 7393-2) | ||
| 253 | Waste water, drinking water, ground water, surface water, raw water, process water and bathing water | Determination of temperature Regulated area: Tests |
C.1.1/UL/25 (ČSN 75 7342) | ||
| 254 | Drinking water, surface water, ground water, raw water and process water | Determination of oxygen saturation by luminescence Regulated area: Tests |
C.1.1/UL/83 (Metodika firmy HACH; ČSN ISO 17289) | ||
| 255 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of absorbance at 254 nm by spectrophotometry Regulated area: Tests |
C.1.1/UL/69 (ČSN 75 7360) | ||
| 256 | Drinking water, ground water, surface water, raw water and process water | Determination of colour by spectrophotometry Regulated area: Tests |
C.1.1/UL/66 (ČSN EN ISO 7887) | ||
| 257 | Drinking water, ground water, surface water, raw water and process water | Determination of orthophosphates by spectrophotometry with ammonium molybdate Regulated area: Tests |
C.1.1/UL/64 (ČSN EN ISO 6878, čl. 4) | ||
| 258 | Drinking water, ground water, surface water, raw water and process water | Determination of humic substances by spectrophotometry after extraction Regulated area: Tests |
C.1.1/UL/71C (ČSN 75 7536) | ||
| 259 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of nitrates by UV spectrophotometry Regulated area: Tests |
C.1.1/UL/72C (Vodní hospodářství 2/1988 – řada B) | ||
| 260 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of oxidation-reduction potential (ORP) by potentiometry Regulated area: Tests |
C.1.1/UL/73 (ČSN 75 7367) | ||
| 261 | Bathing water | Sensory determination of transparency Regulated area: Tests |
C.1.1/UL/89 (ČSN 75 7340; ČSN EN ISO 7027-2, čl. 5.2.1.1.) | ||
| 262 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of total organic carbon (TOC) by high-temperature decomposition with IR detection Regulated area: Tests |
C.1.1/UL/82 (ČSN EN 1484) | ||
| 263 | Drinking water, ground water, surface water, raw water, process water and bathing water | Determination of ammonium ions by spectrophotometry using the BluVision automatic analyser Regulated area: Tests |
C.1.1/UL/90 (Metodika firmy Skalar; ČSN ISO 7150-1; ČSN EN ISO 15923-1) | ||
| 264 | Drinking water, ground water, surface water, raw water and process water | Determination of nitrites by spectrophotometry using the BluVision automatic analyser Regulated area: Tests |
C.1.1/UL/91 (Metodika firmy Skalar; ČSN EN 26777; ČSN EN ISO 15923-1) | ||
| 265 | Drinking water, ground water, surface water, raw water and process water | Determination of orthophosphates by spectrophotometry with ammonium molybdate using the BluVision automatic analyser Regulated area: Tests |
C.1.1/UL/92 (Metodika firmy Skalar; ČSN EN ISO 6878, čl. 4; ČSN EN ISO 15923-1) | ||
| 266 | Drinking water, ground water, surface water, raw water and process water | Determination of sulphates by turbidimetry using the BluVision automatic analyser Regulated area: Tests |
C.1.1/UL/93 (Metodika firmy Skalar; ČSN EN ISO 15923-1) | ||
| 267 | Drinking water, ground water, surface water, raw water and process water | Determination of aluminium by spectrophotometry with pyrocatechol violet using the BluVision automatic analyser Regulated area: Tests |
C.1.1/UL/94 (Metodika firmy Skalar; ČSN ISO 10566; ISO/TS 15923-2) | ||
| 268 | Drinking water, ground water, surface water, raw water and process water | Determination of iron by spectrophotometry using the BluVision automatic analyser Regulated area: Tests |
C.1.1/UL/95 (Metodika firmy Skalar; ČSN ISO 6332; ISO/TS 15923-2) | ||
| 269 | Drinking water, ground water, surface water, raw water and process water | Determination of manganese by spectrophotometry using the BluVision automatic analyser Regulated area: Tests |
C.1.1/UL/96 (Metodika firmy Skalar; ČSN ISO 6333; ISO/TS 15923-2) | ||
| 270 | Drinking water, ground water, surface water, raw water and process water | Determination of calcium by spectrophotometry using the BluVision automatic analyser and calculation of the sum of calcium and magnesium Regulated area: Tests |
C.1.1/UL/97 (Metodika firmy Skalar; ISO/TS 15923-2) | ||
| 271 | Drinking water, ground water, surface water, raw water and process water | Determination of magnesium by spectrophotometry using the BluVision automatic analyser Regulated area: Tests |
C.1.1/UL/98 (Metodika firmy Skalar; ISO/TS 15923-2) | ||
| 272 | Drinking water, raw water, process water and hot water | Sampling of drinking, raw, process and hot water Regulated area: Sampling |
C.2.1/ÚKJ/1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN ISO 5667-21; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.) | ||
| 273 | Bathing water | Sampling of bathing water Regulated area: Sampling |
C.2.1/ÚKJ/4 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 238/2011 Sb.) | ||
| Laboratory Centre Ústí nad Labem, WWTP Laboratory Česká Lípa (P3D) | |||||
| 274 | Waste water and raw water | Determination of ammonium ions by spectrophotometry and calculation of ammonium and inorganic nitrogen Regulated area: Tests |
C.1.1/UL/47 (ČSN ISO 7150-1) | ||
| 275 | Waste water and raw water | Determination of nitrates by spectrophotometry with sulfosalicylic acid and calculation of nitrate nitrogen Regulated area: Tests |
C.1.1/UL/48 (ČSN ISO 7890-3) | ||
| 276 | Waste water and raw water | Determination of nitrites by spectrophotometry and calculation of nitrite nitrogen Regulated area: Tests |
C.1.1/UL/49 (ČSN EN 26777) | ||
| 277 | Waste water, raw water and liquid waste | Determination of pH by potentiometry Regulated area: Tests |
C.1.1/UL/50 (ČSN ISO 10523) | ||
| 278 | Waste water, ground water, surface water and raw water | Determination of biochemical oxygen demand after n days (BODn) by luminescence Regulated area: Tests |
C.1.1/UL/88D (ČSN EN ISO 5815-1; ČSN ISO 17289) | ||
| 279 | Waste water, ground water, surface water, raw water and liquid waste | Determination of total phosphorus by spectrophotometry with ammonium molybdate Regulated area: Tests |
C.1.1/UL/53 (ČSN EN ISO 6878, čl. 7) | ||
| 280 | Waste water, ground water, surface water and raw water | Determination of suspended solids (NL) by gravimetry – filtration through glass fibre filters Regulated area: Tests |
C.1.1/UL/54 (ČSN EN 872) | ||
| 281 | Waste water, raw water and liquid waste | Determination of dissolved solids (RL) by gravimetry Regulated area: Tests |
C.1.1/UL/55 (ČSN 75 7346) | ||
| 282 | Waste water, ground water, surface water, raw water and liquid waste | Determination of total nitrogen by oxidative digestion with peroxodisulphate by spectrophotometry using a HACH kit and calculation of organic nitrogen Regulated area: Tests |
C.1.1/UL/56 (Metodika firmy HACH) | ||
| 283 | Waste water, drinking water, ground water, surface water, raw water, process water and bathing water | Determination of temperature Regulated area: Tests |
C.1.1/UL/25 (ČSN 75 7342) | ||
| 284 | Waste water and liquid waste | Determination of dissolved inorganic salts (RAS) by gravimetry Regulated area: Tests |
C.1.1/UL/68D (ČSN 75 7347) | ||
| 285 | Sludge | Determination of pH by potentiometry Regulated area: Tests |
C.1.1/UL/57D (ČSN EN ISO 10390) | ||
| 286 | Sludge and liquid waste | Determination of dry matter (total solids) by gravimetry Regulated area: Tests |
C.1.1/UL/58D (ČSN EN 12880) | ||
| 287 | Sludge | Determination of loss on ignition by gravimetry Regulated area: Tests |
C.1.1/UL/59D (ČSN EN 12879:2001) | ||
| 288 | Waste water, ground water, surface water, raw water and liquid waste | Determination of chemical oxygen demand by dichromate (CODCr) by spectrophotometry using a HACH kit Regulated area: Tests |
C.1.1/UL/60D (ČSN ISO 15705; Metodika firmy HACH) | ||
| 289 | Waste water | Determination of colour by spectrophotometry Regulated area: Tests |
C.1.1/UL/65 (ČSN EN ISO 7887) | ||
| 290 | Waste water | Sampling of waste water (manually and by automatic sampler) Regulated area: Sampling |
C.2.1/ÚKJ/2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) | ||
| 291 | Sludge | Sampling of sludge from wastewater and water treatment plants Regulated area: Sampling |
C.2.1/ÚKJ/3 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ČSN EN 16179) | ||
| 292 | Waste | Sampling of solid waste Regulated area: Sampling |
C.2.1/ÚKJ/5 (ČSN EN ISO 5667-15; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008); Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006)) | ||
| 293 | Sediment | Sampling of sediments Regulated area: Sampling |
C.2.1/ÚKJ/7 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-15; ČSN ISO 5667-12; Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006)) | ||
| 294 | Liquid waste | Sampling of liquid waste Regulated area: Sampling |
C.2.1/ÚKJ/8 (TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; ČSN EN 14899; ČSN EN ISO 5667-14; ČSN 01 5112; Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008)) | ||
Reference standards (416)
AHEM č.1/2008, Státní zdravotní ústav v Praze
AOAC 973.51
ASTM D 516-88
C.1.1/LB/1
C.1.1/LB/10
C.1.1/LB/101
C.1.1/LB/103
C.1.1/LB/104
C.1.1/LB/105
C.1.1/LB/107a
C.1.1/LB/107b
C.1.1/LB/108
C.1.1/LB/109
C.1.1/LB/110
C.1.1/LB/11a
C.1.1/LB/11b
C.1.1/LB/12
C.1.1/LB/122
C.1.1/LB/125
C.1.1/LB/127
C.1.1/LB/128
C.1.1/LB/13
C.1.1/LB/14
C.1.1/LB/21a
C.1.1/LB/22
C.1.1/LB/23
C.1.1/LB/24
C.1.1/LB/25
C.1.1/LB/26
C.1.1/LB/27
C.1.1/LB/28 – A
C.1.1/LB/28 – B
C.1.1/LB/29 – A
C.1.1/LB/29 – B
C.1.1/LB/30
C.1.1/LB/31
C.1.1/LB/32
C.1.1/LB/33
C.1.1/LB/34
C.1.1/LB/35
C.1.1/LB/36
C.1.1/LB/37a
C.1.1/LB/37b
C.1.1/LB/38
C.1.1/LB/4
C.1.1/LB/42
C.1.1/LB/43
C.1.1/LB/46b
C.1.1/LB/46c
C.1.1/LB/47
C.1.1/LB/48
C.1.1/LB/49
C.1.1/LB/5
C.1.1/LB/50
C.1.1/LB/51
C.1.1/LB/52
C.1.1/LB/53
C.1.1/LB/54
C.1.1/LB/56
C.1.1/LB/57
C.1.1/LB/59
C.1.1/LB/60
C.1.1/LB/61
C.1.1/LB/62
C.1.1/LB/63
C.1.1/LB/64
C.1.1/LB/65
C.1.1/LB/66
C.1.1/LB/7
C.1.1/LB/8
C.1.1/LB/9
C.1.1/LB/93
C.1.1/LB/94
C.1.1/LB/95
C.1.1/MO/100
C.1.1/MO/101
C.1.1/MO/102
C.1.1/MO/103
C.1.1/MO/104
C.1.1/MO/105
C.1.1/MO/106
C.1.1/MO/107
C.1.1/MO/108
C.1.1/MO/11
C.1.1/MO/15a
C.1.1/MO/15b
C.1.1/MO/17
C.1.1/MO/19
C.1.1/MO/20
C.1.1/MO/21
C.1.1/MO/28
C.1.1/MO/31
C.1.1/MO/37
C.1.1/MO/38
C.1.1/MO/39
C.1.1/MO/4
C.1.1/MO/40
C.1.1/MO/41
C.1.1/MO/42
C.1.1/MO/43
C.1.1/MO/44
C.1.1/MO/46
C.1.1/MO/48
C.1.1/MO/49
C.1.1/MO/52
C.1.1/MO/54
C.1.1/MO/56
C.1.1/MO/57
C.1.1/MO/58
C.1.1/MO/59
C.1.1/MO/5a
C.1.1/MO/6
C.1.1/MO/60
C.1.1/MO/61
C.1.1/MO/62
C.1.1/MO/63
C.1.1/MO/71
C.1.1/MO/72
C.1.1/MO/73
C.1.1/MO/74
C.1.1/MO/75
C.1.1/MO/76
C.1.1/MO/77
C.1.1/MO/78
C.1.1/MO/79
C.1.1/MO/7a
C.1.1/MO/80
C.1.1/MO/81
C.1.1/MO/82
C.1.1/MO/83
C.1.1/MO/84
C.1.1/MO/85
C.1.1/MO/86
C.1.1/MO/87
C.1.1/MO/88
C.1.1/MO/89
C.1.1/MO/91
C.1.1/MO/92
C.1.1/MO/93
C.1.1/MO/94
C.1.1/MO/95
C.1.1/MO/96
C.1.1/MO/97
C.1.1/MO/98
C.1.1/MO/99
C.1.1/UL/10
C.1.1/UL/12
C.1.1/UL/13
C.1.1/UL/14B
C.1.1/UL/15
C.1.1/UL/16
C.1.1/UL/19B
C.1.1/UL/1B
C.1.1/UL/23
C.1.1/UL/24
C.1.1/UL/25
C.1.1/UL/26
C.1.1/UL/27
C.1.1/UL/29
C.1.1/UL/2B
C.1.1/UL/30
C.1.1/UL/31
C.1.1/UL/32
C.1.1/UL/33
C.1.1/UL/34
C.1.1/UL/35
C.1.1/UL/36
C.1.1/UL/37
C.1.1/UL/38
C.1.1/UL/39
C.1.1/UL/3B
C.1.1/UL/40
C.1.1/UL/42
C.1.1/UL/44
C.1.1/UL/46
C.1.1/UL/47
C.1.1/UL/48
C.1.1/UL/49
C.1.1/UL/4A
C.1.1/UL/4B
C.1.1/UL/50
C.1.1/UL/53
C.1.1/UL/54
C.1.1/UL/55
C.1.1/UL/56
C.1.1/UL/57B
C.1.1/UL/57D
C.1.1/UL/58B
C.1.1/UL/58D
C.1.1/UL/59B
C.1.1/UL/59D
C.1.1/UL/5A
C.1.1/UL/60B
C.1.1/UL/60D
C.1.1/UL/61A
C.1.1/UL/61C
C.1.1/UL/62
C.1.1/UL/63
C.1.1/UL/64
C.1.1/UL/65
C.1.1/UL/66
C.1.1/UL/68B
C.1.1/UL/68D
C.1.1/UL/69
C.1.1/UL/7
C.1.1/UL/71A
C.1.1/UL/71C
C.1.1/UL/72A
C.1.1/UL/72C
C.1.1/UL/73
C.1.1/UL/74
C.1.1/UL/75
C.1.1/UL/76
C.1.1/UL/77
C.1.1/UL/78
C.1.1/UL/79
C.1.1/UL/8
C.1.1/UL/80
C.1.1/UL/81
C.1.1/UL/82
C.1.1/UL/83
C.1.1/UL/84
C.1.1/UL/85
C.1.1/UL/86
C.1.1/UL/87
C.1.1/UL/88B
C.1.1/UL/88D
C.1.1/UL/89
C.1.1/UL/9
C.1.1/UL/90
C.1.1/UL/91
C.1.1/UL/92
C.1.1/UL/93
C.1.1/UL/94
C.1.1/UL/95
C.1.1/UL/96
C.1.1/UL/97
C.1.1/UL/98
C.1.1/UL/BI-1A
C.1.1/UL/BI-1C
C.1.1/UL/BI-2A
C.1.1/UL/BI-2C
C.1.1/UL/MB-10
C.1.1/UL/MB-11
C.1.1/UL/MB-12
C.1.1/UL/MB-13
C.1.1/UL/MB-14
C.1.1/UL/MB-4
C.1.1/UL/MB-57
C.1.1/UL/MB-58
C.1.1/UL/MB-6
C.1.1/UL/MB-60
C.1.1/UL/MB-62
C.1.1/UL/MB-63
C.1.1/UL/MB-64
C.1.1/UL/MB-65
C.1.1/UL/MB-66
C.1.1/UL/MB-8
C.1.1/UL/MB-9
C.2.1/ÚKJ/1
C.2.1/ÚKJ/2
C.2.1/ÚKJ/3
C.2.1/ÚKJ/4
C.2.1/ÚKJ/5
C.2.1/ÚKJ/6
C.2.1/ÚKJ/7
C.2.1/ÚKJ/8
DIN 38414-17
DIN ISO 15009
EPA 375.4
EPA Method 325.2
EPA Method 340.3
EPA Method 353.1
EPA Method 375.4
EPA Method 502.2
EPA Method 505
EPA Method 536
ISO/TS 15923-2
Manuál firmy Altec
Manuál firmy Milestone
Metodický pokyn MŽP – Vzorkovací práce v sanační geologii (2006)
Metodika firmy Altec
Metodika firmy Bruker
Metodika firmy HACH
Metodika firmy LABTECH
Metodika firmy OHAUS
Metodika firmy Skalar
Postup firmy Thermo Fisher Scientific
TNI 75 7531
TNI CEN/TR 15310-1
TNI CEN/TR 15310-2
TNI CEN/TR 15310-3
TNI CEN/TR 15310-4
TNI CEN/TR 15310-5
Vodní hospodářství 2/1988 B
Vodní hospodářství 2/1988 – řada B
Vodní hospodářství 7/1984 B
Vodní hospodářství č. 2/1988 – řada B
Vyhláška č. 238/2011 Sb.
Vyhláška č. 252/2004 Sb.
Věstník MŽP, částka 4, ročník XVIII – Metodický pokyn ke vzorkování odpadů (duben 2008)
ČSN 01 5112
ČSN 75 7315
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7360
ČSN 75 7367
ČSN 75 7372
ČSN 75 7385
ČSN 75 7422
ČSN 75 7440
ČSN 75 7508
ČSN 75 7536
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN 757342
ČSN EN 12176:2014
ČSN EN 12879:2001
ČSN EN 12880
ČSN EN 13137:2002
ČSN EN 13342
ČSN EN 14039
ČSN EN 14346:2007
ČSN EN 1484
ČSN EN 14899
ČSN EN 15216
ČSN EN 15934
ČSN EN 15935
ČSN EN 15936
ČSN EN 16166
ČSN EN 16173
ČSN EN 16179
ČSN EN 1622
ČSN EN 17322
ČSN EN 25663
ČSN EN 26777
ČSN EN 27 888
ČSN EN 27888
ČSN EN 872
ČSN EN 901
ČSN EN 903
ČSN EN ISO 10304-1
ČSN EN ISO 10304-4
ČSN EN ISO 10390
ČSN EN ISO 11731
ČSN EN ISO 11732
ČSN EN ISO 11885
ČSN EN ISO 11905-1
ČSN EN ISO 13395
ČSN EN ISO 14189
ČSN EN ISO 14402
ČSN EN ISO 14403-2
ČSN EN ISO 15061
ČSN EN ISO 15587-1
ČSN EN ISO 15587-2
ČSN EN ISO 15682
ČSN EN ISO 15923-1
ČSN EN ISO 16173
ČSN EN ISO 16266
ČSN EN ISO 17289
ČSN EN ISO 17294-2
ČSN EN ISO 17503
ČSN EN ISO 17993
ČSN EN ISO 19458
ČSN EN ISO 54321
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-16
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5814
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878, čl. 4
ČSN EN ISO 6878, čl. 4 a čl. 7
ČSN EN ISO 6878, čl. 7
ČSN EN ISO 6888-1
ČSN EN ISO 7027-1
ČSN EN ISO 7027-2 čl. 5.2.1.1.
ČSN EN ISO 7027-2, čl. 5.2.1.1
ČSN EN ISO 7027-2, čl. 5.2.1.1.
ČSN EN ISO 7383-2
ČSN EN ISO 7393-2
ČSN EN ISO 7887
ČSN EN ISO 7887, metoda C
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9308-2
ČSN EN ISO 9377-2
ČSN EN ISO 9562
ČSN EN ISO 9963-1
ČSN ISO 10359-1
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 15705
ČSN ISO 17289
ČSN ISO 21676
ČSN ISO 5667-10
ČSN ISO 5667-12
ČSN ISO 5667-21
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 7980
ČSN ISO 9297