🇨🇿 Šumavské vodovody a kanalizace a.s. PL
Water & wastewaterMicrobiology
Šumavské vodovody a kanalizace a.s. is a laboratory accredited by ČIA under number 1335 (Klatovy, Czech Republic). Its accreditation scope covers 34 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Drinking water, treated water, raw water, Drinking water, treated water, raw water, waste water, Drinking, treated and raw water, Waste water.
At a glance
- Accreditation number: ČIA 1335
- Methods in scope: 34
- Types of test objects: 4
- City: Klatovy, Czech Republic
- Valid until: 10-02-2030
- Accreditation number
- 1335
- Accreditation body
- ČIA
- Address
- Koldinova 530, 339 01 Klatovy
- City
- Klatovy, Czech Republic
- Division
- Laboratorium ŠVK
- Valid until
- 10-02-2030
What this laboratory tests (4)
- Drinking water, treated water, raw water — 21 methods
- Drinking water, treated water, raw water, waste water — 11 methods
- Drinking, treated and raw water — 1 method
- Waste water — 1 method
Certificate information
- Certificate date
- 10.02.2025
Accreditation scope — test methods (34)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Drinking water, treated water, raw water | Determination of acid neutralizing capacity (KNK) by titration Regulated area: Tests |
SOP 1 (ČSN EN ISO 9963-1) | ||
| 2 | Drinking water, treated water, raw water, waste water | Determination of ammonium ions by photometry, ammonium nitrogen by calculation and inorganic nitrogen by calculation from measured values Regulated area: Tests |
SOP 2 (ČSN ISO 7150-1) | ||
| 3 | Drinking water, treated water, raw water | Determination of chemical oxygen demand (CODMn) by titration Regulated area: Tests |
SOP 3 (ČSN EN ISO 8467) | ||
| 4 | Drinking water, treated water, raw water | Determination of chlorides by titration Regulated area: Tests |
SOP 4 (ČSN ISO 9297) | ||
| 5 | Drinking water, treated water, raw water, waste water | Determination of nitrates by photometry and nitrate nitrogen by calculation Regulated area: Tests |
SOP 5 (ČSN ISO 7890-3) | ||
| 6 | Drinking water, treated water, raw water, waste water | Determination of nitrites by photometry and nitrite nitrogen by calculation Regulated area: Tests |
SOP 6 (ČSN EN 26777) | ||
| 7 | Drinking water, treated water, raw water, waste water | Determination of water reaction (pH) by potentiometry Regulated area: Tests |
SOP 7 (ČSN ISO 10523) | ||
| 8 | Drinking water, treated water, raw water | Determination of sulphates by photometry Regulated area: Tests |
SOP 8 (DIN 38405-5) | ||
| 9 | Drinking water, treated water, raw water | Determination of electrical conductivity Regulated area: Tests |
SOP 9 (ČSN EN 27888) | ||
| 10 | Drinking water, treated water, raw water | Determination of dissolved solids and dissolved inorganic salts (RAS) by gravimetry Regulated area: Tests |
SOP10 (ČSN 75 7346; ČSN 75 7347) | ||
| 11 | Drinking water, treated water, raw water | Determination of the sum of calcium and magnesium by titration and of magnesium by calculation Regulated area: Tests |
SOP 11 (ČSN ISO 6058; ČSN ISO 6059) | ||
| 12 | Drinking water, treated water, raw water | Determination of calcium by titration Regulated area: Tests |
SOP 12 (ČSN ISO 6058) | ||
| 13 | Drinking water, treated water, raw water | Determination of turbidity by nephelometry Regulated area: Tests |
SOP 13 (ČSN EN ISO 7027-1) | ||
| 14 | Drinking water, treated water, raw water | Determination of colour by photometry Regulated area: Tests |
SOP 14 (ČSN EN ISO 7887) | ||
| 15 | Drinking water, treated water, raw water | Determination of manganese by photometry Regulated area: Tests |
SOP 15 (ČSN ISO 6333) | ||
| 16 | Drinking water, treated water, raw water | Determination of aluminium by photometry Regulated area: Tests |
SOP 16 (ČSN ISO 10566) | ||
| 17 | Drinking water, treated water, raw water | Determination of iron by photometry Regulated area: Tests |
SOP 17 (ČSN ISO 6332) | ||
| 18 | Drinking water, treated water, raw water | Determination of dried suspended solids and loss on ignition of suspended solids by gravimetry Regulated area: Tests |
SOP 10 (ČSN EN 872; ČSN 75 7350) | ||
| 19 | Drinking water, treated water, raw water, waste water | Determination of phosphates and total phosphorus by photometry Regulated area: Tests |
SOP 19 (ČSN EN ISO 6878) | ||
| 20 | Drinking water, treated water, raw water, waste water | Determination of chemical oxygen demand (CODCr) by photometry Regulated area: Tests |
SOP 20 (ČSN ISO 15705) | ||
| 21 | Drinking water, treated water, raw water, waste water | Determination of biochemical oxygen demand after n days (BODn) with an oxygen probe Regulated area: Tests |
SOP 21 - část A (ČSN ISO 17289; ČSN EN 1899-2; ČSN EN ISO 5815-1) | ||
| 22 | Drinking water, treated water, raw water, waste water | Determination of biochemical oxygen demand after n days (BODn) by iodometry Regulated area: Tests |
SOP 21 - část B (ČSN EN 25813; ČSN EN 1899-2) | ||
| 23 | Drinking water, treated water, raw water | Determination of free and total chlorine by photometry with the Hach commercial analytical kit Regulated area: Tests |
SOP 28 (ČSN ISO 7393-2; návod firmy Hach Lange) | ||
| 24 | Drinking water, treated water, raw water, waste water | Determination of total nitrogen by photometry and organic nitrogen by calculation Regulated area: Tests |
SOP 30 (ČSN 75 7455) | ||
| 25 | Drinking water, treated water, raw water | Indicative determination of odour and taste Regulated area: Tests |
SOP 31 (ČSN 75 7340) | ||
| 26 | Drinking water, treated water, raw water, waste water | Determination of temperature Regulated area: Tests |
SOP 33 (ČSN 75 7342) | ||
| 27 | Drinking water, treated water, raw water | Determination of base neutralizing capacity (ZNK) by titration Regulated area: Tests |
SOP 34 (ČSN 75 7342) | ||
| 28 | Drinking water, treated water, raw water, waste water | Determination of dissolved oxygen with an oxygen probe Regulated area: Tests |
SOP 21 - část A (ČSN ISO 17289) | ||
| 29 | Drinking water, treated water, raw water | Determination of thermotolerant coliform bacteria by membrane filtration Regulated area: Tests |
SOP 22 (ČSN 75 7835) | ||
| 30 | Drinking water, treated water, raw water | Determination of Escherichia coli and coliform bacteria by membrane filtration Regulated area: Tests |
SOP 23 (ČSN EN ISO 9308-1) | ||
| 31 | Drinking water, treated water, raw water | Determination of intestinal enterococci by membrane filtration Regulated area: Tests |
SOP 24 (ČSN EN ISO 7899-2) | ||
| 32 | Drinking water, treated water, raw water | Enumeration of culturable microorganisms by inoculation in a nutrient culture medium at 22 °C and 36 °C Regulated area: Tests |
SOP 27 (ČSN EN ISO 6222) | ||
| 33 | Drinking, treated and raw water | Sampling of drinking, treated and raw water Regulated area: Sampling |
SOP 1/V (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN ISO 5667-5; ČSN ISO 5667-20; ČSN ISO 5667-24; ČSN EN ISO 19458) | ||
| 34 | Waste water | Sampling of waste water (manual sampling and sampling with an automatic sampler) Regulated area: Sampling |
SOP 2/V (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN ISO 5667-10; ČSN ISO 5667-17; ČSN ISO 5667-20; ČSN ISO 5667-24) | ||
Reference standards (77)
DIN 38405-5
SOP 1
SOP 1/V
SOP 10
SOP 11
SOP 12
SOP 13
SOP 14
SOP 15
SOP 16
SOP 17
SOP 19
SOP 2
SOP 2/V
SOP 20
SOP 21 - část A
SOP 21 - část B
SOP 22
SOP 23
SOP 24
SOP 27
SOP 28
SOP 3
SOP 30
SOP 31
SOP 33
SOP 34
SOP 4
SOP 5
SOP 6
SOP 7
SOP 8
SOP 9
SOP10
návod firmy Hach Lange
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7350
ČSN 75 7455
ČSN 75 7835
ČSN EN 1899-2
ČSN EN 25813
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 19458
ČSN EN ISO 5667-1
ČSN EN ISO 5667-14
ČSN EN ISO 5667-3
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878
ČSN EN ISO 7027-1
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9963-1
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 15705
ČSN ISO 17289
ČSN ISO 5667-10
ČSN ISO 5667-17
ČSN ISO 5667-20
ČSN ISO 5667-24
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150-1
ČSN ISO 7393-2
ČSN ISO 7890-3
ČSN ISO 9297