🇨🇿 Šumavské vodovody a kanalizace a.s. PL

ČIA 1335 • Klatovy, Czech Republic • 34 methods

Water & wastewaterMicrobiology

Šumavské vodovody a kanalizace a.s. is a laboratory accredited by ČIA under number 1335 (Klatovy, Czech Republic). Its accreditation scope covers 34 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Drinking water, treated water, raw water, Drinking water, treated water, raw water, waste water, Drinking, treated and raw water, Waste water.

At a glance

  • Accreditation number: ČIA 1335
  • Methods in scope: 34
  • Types of test objects: 4
  • City: Klatovy, Czech Republic
  • Valid until: 10-02-2030
Accreditation number
1335
Accreditation body
ČIA
Address
Koldinova 530, 339 01 Klatovy
City
Klatovy, Czech Republic
Division
Laboratorium ŠVK
Valid until
10-02-2030

What this laboratory tests (4)

Certificate information

Certificate date
10.02.2025

Accreditation scope — test methods (34)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Drinking water, treated water, raw water Determination of acid neutralizing capacity (KNK) by titration
Regulated area: Tests
SOP 1 (ČSN EN ISO 9963-1)
2 Drinking water, treated water, raw water, waste water Determination of ammonium ions by photometry, ammonium nitrogen by calculation and inorganic nitrogen by calculation from measured values
Regulated area: Tests
SOP 2 (ČSN ISO 7150-1)
3 Drinking water, treated water, raw water Determination of chemical oxygen demand (CODMn) by titration
Regulated area: Tests
SOP 3 (ČSN EN ISO 8467)
4 Drinking water, treated water, raw water Determination of chlorides by titration
Regulated area: Tests
SOP 4 (ČSN ISO 9297)
5 Drinking water, treated water, raw water, waste water Determination of nitrates by photometry and nitrate nitrogen by calculation
Regulated area: Tests
SOP 5 (ČSN ISO 7890-3)
6 Drinking water, treated water, raw water, waste water Determination of nitrites by photometry and nitrite nitrogen by calculation
Regulated area: Tests
SOP 6 (ČSN EN 26777)
7 Drinking water, treated water, raw water, waste water Determination of water reaction (pH) by potentiometry
Regulated area: Tests
SOP 7 (ČSN ISO 10523)
8 Drinking water, treated water, raw water Determination of sulphates by photometry
Regulated area: Tests
SOP 8 (DIN 38405-5)
9 Drinking water, treated water, raw water Determination of electrical conductivity
Regulated area: Tests
SOP 9 (ČSN EN 27888)
10 Drinking water, treated water, raw water Determination of dissolved solids and dissolved inorganic salts (RAS) by gravimetry
Regulated area: Tests
SOP10 (ČSN 75 7346; ČSN 75 7347)
11 Drinking water, treated water, raw water Determination of the sum of calcium and magnesium by titration and of magnesium by calculation
Regulated area: Tests
SOP 11 (ČSN ISO 6058; ČSN ISO 6059)
12 Drinking water, treated water, raw water Determination of calcium by titration
Regulated area: Tests
SOP 12 (ČSN ISO 6058)
13 Drinking water, treated water, raw water Determination of turbidity by nephelometry
Regulated area: Tests
SOP 13 (ČSN EN ISO 7027-1)
14 Drinking water, treated water, raw water Determination of colour by photometry
Regulated area: Tests
SOP 14 (ČSN EN ISO 7887)
15 Drinking water, treated water, raw water Determination of manganese by photometry
Regulated area: Tests
SOP 15 (ČSN ISO 6333)
16 Drinking water, treated water, raw water Determination of aluminium by photometry
Regulated area: Tests
SOP 16 (ČSN ISO 10566)
17 Drinking water, treated water, raw water Determination of iron by photometry
Regulated area: Tests
SOP 17 (ČSN ISO 6332)
18 Drinking water, treated water, raw water Determination of dried suspended solids and loss on ignition of suspended solids by gravimetry
Regulated area: Tests
SOP 10 (ČSN EN 872; ČSN 75 7350)
19 Drinking water, treated water, raw water, waste water Determination of phosphates and total phosphorus by photometry
Regulated area: Tests
SOP 19 (ČSN EN ISO 6878)
20 Drinking water, treated water, raw water, waste water Determination of chemical oxygen demand (CODCr) by photometry
Regulated area: Tests
SOP 20 (ČSN ISO 15705)
21 Drinking water, treated water, raw water, waste water Determination of biochemical oxygen demand after n days (BODn) with an oxygen probe
Regulated area: Tests
SOP 21 - část A (ČSN ISO 17289; ČSN EN 1899-2; ČSN EN ISO 5815-1)
22 Drinking water, treated water, raw water, waste water Determination of biochemical oxygen demand after n days (BODn) by iodometry
Regulated area: Tests
SOP 21 - část B (ČSN EN 25813; ČSN EN 1899-2)
23 Drinking water, treated water, raw water Determination of free and total chlorine by photometry with the Hach commercial analytical kit
Regulated area: Tests
SOP 28 (ČSN ISO 7393-2; návod firmy Hach Lange)
24 Drinking water, treated water, raw water, waste water Determination of total nitrogen by photometry and organic nitrogen by calculation
Regulated area: Tests
SOP 30 (ČSN 75 7455)
25 Drinking water, treated water, raw water Indicative determination of odour and taste
Regulated area: Tests
SOP 31 (ČSN 75 7340)
26 Drinking water, treated water, raw water, waste water Determination of temperature
Regulated area: Tests
SOP 33 (ČSN 75 7342)
27 Drinking water, treated water, raw water Determination of base neutralizing capacity (ZNK) by titration
Regulated area: Tests
SOP 34 (ČSN 75 7342)
28 Drinking water, treated water, raw water, waste water Determination of dissolved oxygen with an oxygen probe
Regulated area: Tests
SOP 21 - část A (ČSN ISO 17289)
29 Drinking water, treated water, raw water Determination of thermotolerant coliform bacteria by membrane filtration
Regulated area: Tests
SOP 22 (ČSN 75 7835)
30 Drinking water, treated water, raw water Determination of Escherichia coli and coliform bacteria by membrane filtration
Regulated area: Tests
SOP 23 (ČSN EN ISO 9308-1)
31 Drinking water, treated water, raw water Determination of intestinal enterococci by membrane filtration
Regulated area: Tests
SOP 24 (ČSN EN ISO 7899-2)
32 Drinking water, treated water, raw water Enumeration of culturable microorganisms by inoculation in a nutrient culture medium at 22 °C and 36 °C
Regulated area: Tests
SOP 27 (ČSN EN ISO 6222)
33 Drinking, treated and raw water Sampling of drinking, treated and raw water
Regulated area: Sampling
SOP 1/V (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN ISO 5667-5; ČSN ISO 5667-20; ČSN ISO 5667-24; ČSN EN ISO 19458)
34 Waste water Sampling of waste water (manual sampling and sampling with an automatic sampler)
Regulated area: Sampling
SOP 2/V (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN ISO 5667-10; ČSN ISO 5667-17; ČSN ISO 5667-20; ČSN ISO 5667-24)

Reference standards (77)

DIN 38405-5
SOP 1
SOP 1/V
SOP 10
SOP 11
SOP 12
SOP 13
SOP 14
SOP 15
SOP 16
SOP 17
SOP 19
SOP 2
SOP 2/V
SOP 20
SOP 21 - část A
SOP 21 - část B
SOP 22
SOP 23
SOP 24
SOP 27
SOP 28
SOP 3
SOP 30
SOP 31
SOP 33
SOP 34
SOP 4
SOP 5
SOP 6
SOP 7
SOP 8
SOP 9
SOP10
návod firmy Hach Lange
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7350
ČSN 75 7455
ČSN 75 7835
ČSN EN 1899-2
ČSN EN 25813
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 19458
ČSN EN ISO 5667-1
ČSN EN ISO 5667-14
ČSN EN ISO 5667-3
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878
ČSN EN ISO 7027-1
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9963-1
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 15705
ČSN ISO 17289
ČSN ISO 5667-10
ČSN ISO 5667-17
ČSN ISO 5667-20
ČSN ISO 5667-24
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150-1
ČSN ISO 7393-2
ČSN ISO 7890-3
ČSN ISO 9297

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1335