🇨🇿 Vodovody a kanalizace Hodonín, a.s. PL

ČIA 1330 • Bzenec, Czech Republic • 31 methods

Water & wastewaterMicrobiology

Vodovody a kanalizace Hodonín, a.s. is a laboratory accredited by ČIA under number 1330 (Bzenec, Czech Republic). Its accreditation scope covers 31 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Drinking, raw, surface, ground and process water, Drinking, raw, surface and ground water, Drinking water, Groundwater. Most frequently used techniques: spectrophotometric method, titrimetric method, membrane filtration.

At a glance

  • Accreditation number: ČIA 1330
  • Methods in scope: 31
  • Types of test objects: 5
  • Techniques used: 13
  • City: Bzenec, Czech Republic
  • Valid until: 22-10-2029
Accreditation number
1330
Accreditation body
ČIA
Address
Přívoz, 696 81 Bzenec
City
Bzenec, Czech Republic
Division
Służba Chemiczna Wodociągów, laboratorium stacji uzdatniania wody Bzenec Přívoz
Valid until
22-10-2029

What this laboratory tests (5)

Analytical techniques used (13)

Certificate information

Certificate date
22.10.2024

Accreditation scope — test methods (31)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Drinking, raw, surface, ground and process water Determination of colour spectrophotometrically
Regulated area: Tests
spectrophotometric method I-CHSV-01 (ČSN EN ISO 7887)
2 Drinking, raw, surface, ground and process water Determination of turbidity by nephelometry
Regulated area: Tests
nephelometric method I-CHSV-02b (ČSN EN ISO 7027)
3 Drinking, raw, surface, ground and process water Determination of pH by potentiometry
Regulated area: Tests
potentiometric method I-CHSV-03 (ČSN ISO 10523)
4 Drinking, raw, surface, ground and process water Determination of electrical conductivity by potentiometry
Regulated area: Tests
potentiometric method I-CHSV-04 (ČSN EN ISO 7887)
5 Drinking, raw, surface, ground and process water Determination of chemical oxygen demand by permanganate (CODMn) by titration
Regulated area: Tests
titrimetric method I-CHSV-05 (ČSN EN ISO 8467)
6 Drinking, raw, surface, ground and process water Determination of the sum of calcium and magnesium by titration, determination of magnesium by calculation
magnesium by calculation (calculated)
Regulated area: Tests
titrimetric method I-CHSV-06 (ČSN ISO 6059; ČSN ISO 6058)
7 Drinking, raw, surface, ground and process water Determination of calcium by titration
Regulated area: Tests
titrimetric method I-CHSV-07 (ČSN ISO 6058)
8 Drinking, raw, surface and ground water Determination of odour and taste – sensory analysis
Regulated area: Tests
sensory analysis I-CHSV-101 (ČSN EN 1622; ČSN 75 7340)
9 Drinking, raw, surface, ground and process water Determination of iron spectrophotometrically
Regulated area: Tests
spectrophotometric method I-CHSV-09 (ČCN ISO 6332)
10 Drinking, raw, surface, ground and process water Determination of manganese spectrophotometrically
Regulated area: Tests
spectrophotometric method I-CHSV-10 (ČSN ISO 6333)
11 Drinking, raw, surface, ground and process water Determination of ammonium ions spectrophotometrically and of ammonium nitrogen by calculation
ammonium nitrogen by calculation (calculated)
Regulated area: Tests
spectrophotometric method I-CHSV-11 (ČSN ISO 7150-1)
12 Drinking, raw, surface, ground and process water Determination of acid neutralising capacity KNK 4.5 by titration
Regulated area: Tests
titrimetric method I-CHSV-12 (ČSN EN ISO 9963-1)
13 Drinking, raw, surface, ground and process water Determination of chlorides by argentometry
Regulated area: Tests
argentometric method I-CHSV-13 (ČSN ISO 9297)
14 Drinking, raw, surface, ground and process water Determination of sulphates by titration
Regulated area: Tests
titrimetric method I-CHSV-14 (ČSN 75 7477)
15 Drinking, raw, surface, ground and process water Determination of nitrites spectrophotometrically, of nitrite nitrogen by calculation
nitrite nitrogen by calculation (calculated)
Regulated area: Tests
spectrophotometric method I-CHSV-15 (ČSN EN 26777)
16 Drinking, raw, surface, ground and process water Determination of nitrates spectrophotometrically, of nitrate nitrogen by calculation
nitrate nitrogen by calculation (calculated)
Regulated area: Tests
spectrophotometric method I-CHSV-16 (ČSN ISO 7890-3)
17 Drinking, raw, surface, ground and process water Determination of absorbance at 254 nm spectrophotometrically
Regulated area: Tests
spectrophotometric method I-CHSV-17 (ČSN 75 7360)
18 Drinking, raw, surface, ground and process water Determination of suspended solids by gravimetry
Regulated area: Tests
gravimetric method I-CHSV-19 (ČSN EN 872)
19 Drinking water Determination of free chlorine spectrophotometrically with a commercial Hach analytical kit
Regulated area: Tests
spectrophotometric method, commercial Hach analytical kit I-CHSV-20 (Návod firmy Hach)
20 Drinking water Determination of chlorine dioxide spectrophotometrically with a commercial Hach, Eutech analytical kit
Regulated area: Tests
spectrophotometric method, commercial Hach, Eutech analytical kit I-CHSV-21 (Návod firmy Hach)
21 Drinking, raw, surface, ground and process water Determination of water temperature
Regulated area: Tests
ČSN 75 7342
22 Drinking, raw, surface and ground water Enumeration of Escherichia coli and coliform bacteria by membrane filtration
Regulated area: Tests
membrane filtration I-CHSV-31 (ČSN EN ISO 9308-1; ČSN 75 7837)
23 Drinking, raw, surface and ground water Enumeration of thermotolerant bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
membrane filtration I-CHSV-32 (ČSN EN ISO 9308-1; ČSN 75 7835)
24 Drinking, raw, surface and ground water Enumeration of intestinal enterococci by membrane filtration
Regulated area: Tests
membrane filtration I-CHSV-33 (ČSN EN ISO 7899-2)
25 Drinking, raw, surface and ground water Enumeration of culturable organisms at 22 °C and 36 °C by culture
Regulated area: Tests
culture method I-CHSV-34 (ČSN EN ISO 6222)
26 Drinking, raw, surface and ground water Enumeration of Escherichia coli and coliform bacteria by the most probable number method (Colilert®)
Regulated area: Tests
most probable number method (Colilert®) I-CHSV-36 (ČSN EN ISO 9308-2; návod firmy Idexx)
27 Drinking, raw, surface and ground water Biological analysis – determination of bioseston. Determination of the number of organisms by microscopy
Regulated area: Tests
microscopic method ČSN 75 7712
28 Drinking, raw, surface and ground water Biological analysis – determination of abioseston by microscopy
Regulated area: Tests
microscopic method ČSN 75 7713
29 Drinking water Sampling of drinking water – manual sampling
Regulated area: Sampling
I-CHSV-61 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
30 Surface water Sampling of surface water – manual sampling
Regulated area: Sampling
I-CHSV-62 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
31 Groundwater Sampling of groundwater – manual sampling, sampling with a sampling pump
Regulated area: Sampling
I-CHSV-63 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458)

Reference standards (65)

I-CHSV-01
I-CHSV-02b
I-CHSV-03
I-CHSV-04
I-CHSV-05
I-CHSV-06
I-CHSV-07
I-CHSV-09
I-CHSV-10
I-CHSV-101
I-CHSV-11
I-CHSV-12
I-CHSV-13
I-CHSV-14
I-CHSV-15
I-CHSV-16
I-CHSV-17
I-CHSV-19
I-CHSV-20
I-CHSV-21
I-CHSV-31
I-CHSV-32
I-CHSV-33
I-CHSV-34
I-CHSV-36
I-CHSV-61
I-CHSV-62
I-CHSV-63
Návod firmy Hach
návod firmy Idexx
ČCN ISO 6332
ČSN 75 7340
ČSN 75 7342
ČSN 75 7360
ČSN 75 7477
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN 75 7837
ČSN EN 1622
ČSN EN 26777
ČSN EN 872
ČSN EN ISO 19458
ČSN EN ISO 5667-1
ČSN EN ISO 5667-11
ČSN EN ISO 5667-14
ČSN EN ISO 5667-3
ČSN EN ISO 5667-4
ČSN EN ISO 5667-5
ČSN EN ISO 5667-6
ČSN EN ISO 6222
ČSN EN ISO 7027
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9308-2
ČSN EN ISO 9963-1
ČSN ISO 10523
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6333
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 9297

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1330