🇨🇿 Cemex Czech Republic s.r.o. PL
Construction
Cemex Czech Republic s.r.o. is a laboratory accredited by ČIA under number 1302 (Pardubice, Czech Republic). Its accreditation scope covers 28 test methods in the following areas: Construction. Test objects include: Hardened concrete, Fresh concrete, Aggregates, Hydraulically bound mixtures.
At a glance
- Accreditation number: ČIA 1302
- Methods in scope: 28
- Types of test objects: 7
- City: Pardubice, Czech Republic
- Valid until: 02-04-2029
- Accreditation number
- 1302
- Accreditation body
- ČIA
- Address
- Semtín 102, 533 54 Pardubice
- City
- Pardubice, Czech Republic
- Division
- Laboratorium Badawcze
- Valid until
- 02-04-2029
What this laboratory tests (7)
- Hardened concrete — 10 methods
- Fresh concrete — 7 methods
- Aggregates — 5 methods
- Hydraulically bound mixtures — 3 methods
- Concrete drainage layers — 1 method
- Screed materials — 1 method
- Unbound and hydraulically bound mixtures — 1 method
Certificate information
- Certificate date
- 25.06.2024
Accreditation scope — test methods (28)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Fresh concrete | Determination of consistency - slump test Regulated area: Tests |
ČSN EN 12350-2 | ||
| 2 | Fresh concrete | Determination of consistency - degree of compactibility Regulated area: Tests |
ČSN EN 12350-4 | ||
| 3 | Fresh concrete | Determination of consistency - flow table test Regulated area: Tests |
ČSN EN 12350-5 | ||
| 4 | Fresh concrete | Determination of mass per unit volume Regulated area: Tests |
ČSN EN 12350-6 | ||
| 5 | Fresh concrete | Determination of air content Regulated area: Tests |
ČSN EN 12350-7, mimo čl. 5 | ||
| 6 | Fresh concrete | Slump-flow test Regulated area: Tests |
ČSN EN 12350-8 | ||
| 7 | Hardened concrete | Determination of compressive strength Regulated area: Tests |
ČSN EN 12390-3 | ||
| 8 | Hardened concrete | Determination of flexural strength Regulated area: Tests |
ČSN EN 12390-5 | ||
| 9 | Hardened concrete | Determination of the indirect tensile strength Regulated area: Tests |
ČSN EN 12390-6 | ||
| 10 | Hardened concrete | Determination of mass per unit volume Regulated area: Tests |
ČSN EN 12390-7 | ||
| 11 | Hardened concrete | Determination of depth of penetration of water under pressure Regulated area: Tests |
ČSN EN 12390-8 | ||
| 12 | Hardened concrete | Determination of moisture content and absorption power Regulated area: Tests |
ČSN 73 1316:1989, čl. 2, 4 | ||
| 13 | Hardened concrete | Determination of resistance to frost Regulated area: Tests |
ČSN 73 1322 | ||
| 14 | Hardened concrete | Determination of surface resistance to water and chemical de-icing agents Regulated area: Tests |
ČSN 73 1326, čl. A, C | ||
| 15 | Hardened concrete | Determination of rebound number by Schmidt rebound hammer and subsequent determination of compressive strength Regulated area: Tests |
ČSN 73 1373; ČSN EN 12504-2 | ||
| 16 | Concrete drainage layers | Determination of the volume of voids Regulated area: Tests |
ČSN 73 6124-2, příl. A | ||
| 17 | Hardened concrete | Determination of static modulus of elasticity in compression Regulated area: Tests |
ČSN ISO 1920-10 | ||
| 18 | Screed materials | Determination of flexural strength and compressive strength Regulated area: Tests |
ČSN EN 13892-2 | ||
| 19 | Aggregates | Determination of particle size distribution - Sieving analysis Regulated area: Tests |
ČSN EN 933-1 | ||
| 20 | Aggregates | Determination of particle shape - Shape index Regulated area: Tests |
ČSN EN 933-4 | ||
| 21 | Aggregates | Determination of the water content by drying in a ventilated oven Regulated area: Tests |
ČSN EN 1097-5 | ||
| 22 | Aggregates | Determination of particle density and water absorption Regulated area: Tests |
ČSN EN 1097-6, mimo příl. D | ||
| 23 | Hydraulically bound mixtures | Determination of the workability period Regulated area: Tests |
ČSN EN 13286-45, mimo čl. 6 a příl. A | ||
| 24 | Unbound and hydraulically bound mixtures | Determination of laboratory reference density and water content - Proctor test Regulated area: Tests |
ČSN EN 13286-2, mimo čl. 7.3, 7.6 a Národní příl. NB | ||
| 25 | Hydraulically bound mixtures | Determination of compressive strength Regulated area: Tests |
ČSN EN 13286-41 | ||
| 26 | Hydraulically bound mixtures | Determination of resistance to freezing and water Regulated area: Tests |
ČSN 73 6124-1, příl. A | ||
| 27 | Fresh concrete | Fresh concrete sampling Regulated area: Sampling |
ČSN EN 12350-1 | ||
| 28 | Aggregates | Sampling of aggregates and reduction of samples Regulated area: Sampling |
ČSN EN 932-1; ČSN EN 932-2 | ||
Reference standards (30)
ČSN 73 1316:1989
ČSN 73 1322
ČSN 73 1326
ČSN 73 1373
ČSN 73 6124-1
ČSN 73 6124-2
ČSN EN 1097-5
ČSN EN 1097-6
ČSN EN 12350-1
ČSN EN 12350-2
ČSN EN 12350-4
ČSN EN 12350-5
ČSN EN 12350-6
ČSN EN 12350-7
ČSN EN 12350-8
ČSN EN 12390-3
ČSN EN 12390-5
ČSN EN 12390-6
ČSN EN 12390-7
ČSN EN 12390-8
ČSN EN 12504-2
ČSN EN 13286-2
ČSN EN 13286-41
ČSN EN 13286-45
ČSN EN 13892-2
ČSN EN 932-1
ČSN EN 932-2
ČSN EN 933-1
ČSN EN 933-4
ČSN ISO 1920-10