🇨🇿 Povodí Vltavy, státní podnik PL
Water & wastewaterEnvironmentMicrobiology
Povodí Vltavy, státní podnik is a laboratory accredited by ČIA under number 1252 (Plzeň, Czech Republic). Its accreditation scope covers 63 test methods in the following areas: Water & wastewater, Environment, Microbiology. Test objects include: Drinking, surface, ground and waste water, Drinking, surface, ground, waste and process water, Surface water, Soils, earths, sediments, sludge, suspended solids, settleable susp….
At a glance
- Accreditation number: ČIA 1252
- Methods in scope: 63
- Types of test objects: 20
- City: Plzeň, Czech Republic
- Valid until: 15-02-2028
- Accreditation number
- 1252
- Accreditation body
- ČIA
- Address
- Denisovo nábřeží 2430/14, 301 00 Plzeň
- City
- Plzeň, Czech Republic
- Division
- Laboratorium Gospodarki Wodnej Pilzno
- Valid until
- 15-02-2028
What this laboratory tests (20)
- Drinking, surface, ground and waste water — 10 methods
- Drinking, surface, ground, waste and process water — 8 methods
- Surface water — 8 methods
- Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste — 7 methods
- Drinking, surface and waste water — 4 methods
- Animal and plant material — 3 methods
- Drinking and surface water — 3 methods
- Drinking, surface, ground and waste water, aqueous leachates — 3 methods
- Surface, ground and waste water — 3 methods
- Drinking, ground and surface water — 2 methods
- Drinking, surface and ground water — 2 methods
- Surface and waste water — 2 methods
- Drinking water — 1 method
- Drinking, surface, waste and ground water — 1 method
- Hydrobiological material — 1 method
- and 5 more
Certificate information
- Certificate date
- 28.07.2025
Accreditation scope — test methods (63)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Drinking, surface, ground and waste water, aqueous leachates | Determination of pH by potentiometry Regulated area: Tests |
SOP Z-1a-A (ČSN ISO 10523) | ||
| 2 | Drinking, surface, ground and waste water | Determination of acid neutralising capacity by titration and calculation of CO2 forms from measured values Regulated area: Tests |
SOP Z-2a-A (ČSN EN ISO 9963-1) | ||
| 3 | Drinking, surface, ground and waste water | Determination of electrical conductivity by conductometry Regulated area: Tests |
SOP Z-4a-A (ČSN EN 27888) | ||
| 4 | Drinking, surface and ground water | Determination of absorbance by spectrophotometry Regulated area: Tests |
SOP Z-5a-A (ČSN 75 7360) | ||
| 5 | Drinking, surface and ground water | Determination of turbidity by nephelometry Regulated area: Tests |
SOP Z-6a-A (ČSN EN ISO 7027-1) | ||
| 6 | Surface, ground and waste water, aqueous leachates | Determination of dissolved solids by gravimetry and loss on ignition by calculation from measured values Regulated area: Tests |
SOP Z-7a-A (ČSN 75 7346; ČSN 75 7347) | ||
| 7 | Surface, ground and waste water | Determination of suspended solids by gravimetry and loss on ignition by calculation from measured values Regulated area: Tests |
SOP Z-7b-A (ČSN 75 7350; ČSN EN 872) | ||
| 8 | Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste | Determination of dry matter by gravimetry and loss on ignition Regulated area: Tests |
SOP Z-33-B (ČSN EN 15934; ČSN EN 15935) | ||
| 9 | Surface, ground and waste water | Determination of BODn with electrochemical determination of dissolved oxygen Regulated area: Tests |
SOP Z-9b-A (ČSN EN ISO 5815-1; ČSN EN 1899-2) | ||
| 10 | Drinking, ground and surface water | Determination of COD-Mn by titration Regulated area: Tests |
SOP Z-10b-A (ČSN EN ISO 8467) | ||
| 11 | Surface, ground and waste water | Determination of COD-Cr by spectrophotometry – commercial analytical kit Regulated area: Tests |
SOP Z-11b-A (ČSN ISO 15705; Manuál firmy MERCK) | ||
| 12 | Drinking, ground and surface water | Determination of the sum of calcium and magnesium by titration Regulated area: Tests |
SOP Z-21b-A (ČSN ISO 6059) | ||
| 13 | Drinking, surface, ground and waste water | Determination of free and total cyanides by CFA Regulated area: Tests |
SOP Z-39a-A (ČSN EN ISO 14403-2) | ||
| 14 | Drinking, surface, ground and waste water | Determination of ammoniacal nitrogen by CFA and calculation of ammonium ions from measured values Regulated area: Tests |
SOP Z-12c-A (ČSN EN ISO 11732) | ||
| 15 | Drinking, surface, ground and waste water | Determination of nitrite nitrogen by CFA and calculation of nitrites from measured values Regulated area: Tests |
SOP Z-13c-A (ČSN EN ISO 13395) | ||
| 16 | Drinking, surface, ground and waste water | Determination of nitrate nitrogen by CFA and calculation of nitrates from measured values Regulated area: Tests |
SOP Z-14e-A (ČSN EN ISO 13395) | ||
| 17 | Drinking, surface, ground and waste water | Determination of total nitrogen by CFA and calculation of inorganic and organic nitrogen from measured values Regulated area: Tests |
SOP Z-16c-A (ČSN ISO 29441) | ||
| 18 | Drinking, surface, ground and waste water | Determination of phosphate phosphorus by CFA and calculation of phosphates from measured values Regulated area: Tests |
SOP Z-17c-A (ČSN EN ISO 15681-2) | ||
| 19 | Drinking, surface, ground and waste water | Determination of total phosphorus by CFA Regulated area: Tests |
SOP Z-18d-A (ČSN EN ISO 15681-2) | ||
| 20 | Drinking, surface, ground and waste water, aqueous leachates | Determination of sulphates by CFA Regulated area: Tests |
SOP Z-20e-A (ČSN ISO 22743) | ||
| 21 | Drinking, surface, ground and waste water, aqueous leachates | Determination of chlorides by CFA Regulated area: Tests |
SOP Z-19c-A (ČSN EN ISO 15682) | ||
| 22 | Surface water | Determination of dissolved oxygen with an optical sensor and calculation of saturation in per cent Regulated area: Tests |
SOP Z-8c-A (ČSN EN ISO 17289) | ||
| 23 | Drinking, surface, ground and waste water | Determination of colour by spectrophotometry Regulated area: Tests |
SOP Z-23b-A (ČSN EN ISO 7887) | ||
| 24 | Drinking and surface water | Determination of free and total chlorine by spectrophotometry – commercial analytical kit Regulated area: Tests |
SOP Z-28b-A (ČSN EN ISO 7393-2; Návod firmy HACH) | ||
| 25 | Drinking, surface and waste water | Determination of water temperature Regulated area: Tests |
SOP Z-22a-A (ČSN 75 7342) | ||
| 26 | Surface water | Determination of transparency with a Secchi disc Regulated area: Tests |
SOP Z-26a-A (ČSN 75 7340; ČSN EN ISO 7027-2) | ||
| 27 | Drinking and surface water | Enumeration of coliform bacteria and Escherichia coli by the most probable number method Regulated area: Tests |
SOP B-9-A (ČSN EN ISO 9308-2) | ||
| 28 | Drinking, surface and waste water | Enumeration of culturable micro-organisms at 22 °C and 36 °C by inoculation in a nutrient agar culture medium Regulated area: Tests |
SOP B-13-A (ČSN EN ISO 6222) | ||
| 29 | Surface water | Determination of bioseston – zooplankton by microscopy Regulated area: Tests |
SOP B-5 (ČSN 75 7712; ČSN EN 15110) | ||
| 30 | Surface water | Determination of net plankton by microscopy Regulated area: Tests |
SOP B-6 (ČSN 75 7712) | ||
| 31 | Drinking and surface water | Determination of bioseston – phytoplankton by microscopy and calculation of the phytoplankton saprobic index Regulated area: Tests |
SOP B-1 (ČSN 75 7712; ČSN 75 7716; ČSN 75 7717; ČSN EN 15204) | ||
| 32 | Drinking, surface and waste water | Determination of abioseston by microscopy Regulated area: Tests |
SOP B-2 (ČSN 75 7713) | ||
| 33 | Surface water | Determination of macrozoobenthos by microscopy and calculation of the macrozoobenthos saprobic index Regulated area: Tests |
SOP B-3 (ČSN 75 7701; ČSN 75 7714; ČSN 75 7716; ČSN EN ISO 10870; ČSN EN 17136) | ||
| 34 | Surface water | Determination of chlorophyll-a and phaeopigments by spectrophotometry Regulated area: Tests |
SOP B-7-A (ČSN ISO 10260) | ||
| 35 | Surface and waste water | Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration Regulated area: Tests |
SOP B-11-A (ČSN 75 7835) | ||
| 36 | Drinking, surface and waste water | Enumeration of intestinal enterococci by membrane filtration Regulated area: Tests |
SOP B-12-A (ČSN EN ISO 7899-2) | ||
| 37 | Surface water | Determination of macrophytes by identification Regulated area: Tests |
SOP B-21 (ČSN EN 14184; ČSN EN 15460) | ||
| 38 | Surface and waste water | Determination of biological periphyton (phytobenthos) by microscopy and calculation of the phytobenthos saprobic index Regulated area: Tests |
SOP B-4 (ČSN 75 7715; ČSN 75 7716; ČSN EN 13946; ČSN EN 14407; ČSN EN 15708) | ||
| 39 | Drinking, surface, ground, waste and process water | Determination of glyphosate and AMPA by LC-MS/MS and calculation of the sum of selected analytes from measured values glyphosate AMPA (aminomethylphosphonic acid) glufosinate sum of selected analytes from measured values (calculated) Regulated area: Tests |
SOP O-16-A (ČSN ISO 21458; EPA 547) | ||
| 40 | Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste | Determination of glyphosate and AMPA by LC-MS/MS and calculation of the sum of selected analytes from measured values glyphosate AMPA (aminomethylphosphonic acid) glufosinate sum of selected analytes from measured values (calculated) Regulated area: Tests |
SOP O-16-B (ČSN ISO 21458) | ||
| 41 | Animal and plant material | Determination of glyphosate and AMPA by LC-MS/MS and calculation of the sum of selected analytes from measured values glyphosate AMPA (aminomethylphosphonic acid) glufosinate sum of selected analytes from measured values (calculated) Regulated area: Tests |
SOP O-16-C (ČSN ISO 21458) | ||
| 42 | Drinking, surface, ground, waste and process water | Determination of chloroalkanes C10 to C13 by GC/MSD Regulated area: Tests |
SOP O-17-A (ČSN EN ISO 12010) | ||
| 43 | Drinking, surface, ground, waste and process water | Determination of volatile organic compounds (VOC) by GC/MSD and calculation of the sum of selected analytes from measured values sum of selected analytes from measured values (calculated) Regulated area: Tests |
SOP O-8a-A (ČSN EN ISO 15680; TNV 75 7055) | ||
| 44 | Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste | Determination of volatile organic compounds (VOC) by GC/MSD and calculation of the sum of selected analytes from measured values sum of selected analytes from measured values (calculated) Regulated area: Tests |
SOP O-8a-B (ČSN EN ISO 15680; EPA Method 8260) | ||
| 45 | Drinking, surface, ground, waste and process water | Determination of chlorinated phenols, cresols, naphthols and alkylphenols (CP) by GC/MSD and calculation of the sum of selected analytes sum of selected analytes from measured values (calculated) Regulated area: Tests |
SOP O-13a-A (ČSN EN 12673; ČSN EN ISO 18857-1; ČSN ISO 24293) | ||
| 46 | Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste | Determination of chlorinated phenols, cresols, naphthols and alkylphenols (CP) by GC/MSD and calculation of the sum of selected analytes sum of selected analytes from measured values (calculated) Regulated area: Tests |
SOP O-13a-B (ČSN EN 12673; ČSN EN ISO 18857-1; ČSN ISO 24293; EPA Method 8041A) | ||
| 47 | Drinking, surface, ground, waste and process water | Determination of selected analytes by GC-MS/MS and calculation of the sum of selected analytes from measured values sum of selected analytes from measured values (calculated) Regulated area: Tests |
SOP O-14-A (ČSN EN ISO 6468; ČSN EN ISO 18856; ČSN EN ISO 22032; ČSN P ISO/TS 28581) | ||
| 48 | Drinking, surface, ground, waste and process water | Determination of complexing agents (EDTA) by GC/NPD EDTA NTA 1,3-PDTA Regulated area: Tests |
SOP O-15-A (ČSN EN ISO 16588) | ||
| 49 | Drinking, surface, ground, waste and process water | Determination of hydrocarbons C10 to C40 by GC/FID Regulated area: Tests |
SOP O-2c-A (ČSN EN ISO 9377-2) | ||
| 50 | Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste | Determination of hydrocarbons C10 to C40 by GC/FID Regulated area: Tests |
SOP O-2c-B (ČSN EN 14039; ČSN EN ISO 16703) | ||
| 51 | Drinking, surface, ground, waste and process water | Determination of selected analytes by LC-MS/MS and calculation of the sum of selected analytes from measured values sum of selected analytes from measured values (calculated) Regulated area: Tests |
SOP O-19-A (ČSN ISO 20179; ČSN ISO 25101; EPA Method 535; EPA Method 539; EPA Method 557; EPA Method 1694) | ||
| 52 | Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste | Determination of selected analytes by LC-MS/MS and calculation of the sum of selected analytes from measured values sum of selected analytes from measured values (calculated) Regulated area: Tests |
SOP O-19-B (ČSN ISO 20179) | ||
| 53 | Animal and plant material | Determination of selected analytes by LC-MS/MS and calculation of the sum of selected analytes from measured values sum of selected analytes from measured values (calculated) Regulated area: Tests |
SOP O-19-C (ČSN ISO 20179) | ||
| 54 | Soils, earths, sediments, sludge, suspended solids, settleable suspended solids, solid waste | Determination of selected analytes by GC-MS and calculation of the sum of selected analytes from measured values sum of selected analytes from measured values (calculated) Regulated area: Tests |
SOP O-9a-B (ČSN EN 17322; ČSN EN ISO 18856; ČSN EN ISO 22032) | ||
| 55 | Animal and plant material | Determination of selected analytes by GC-MS and calculation of the sum of selected analytes from measured values sum of selected analytes from measured values (calculated) Regulated area: Tests |
SOP O-9a-C (ČSN EN 17322; ČSN EN ISO 18856; ČSN EN ISO 22032) | ||
| 56 | Drinking, surface, waste and ground water | Determination of oxidation-reduction potential (ORP) by potentiometry Regulated area: Tests |
SOP Z-27a-A (ČSN 75 7367) | ||
| 57 | Drinking water | Sampling of drinking water Regulated area: Sampling |
PP-17-1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.) | ||
| 58 | Surface water | Sampling of surface water (manual and with an automatic sampler) Regulated area: Sampling |
PP-17-2 (ČSN 75 7717; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 238/2011 Sb.) | ||
| 59 | Waste water | Sampling of waste water (manual and with an automatic sampler) Regulated area: Sampling |
PP-17-3 (ČSN 75 7315; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN EN ISO 19458) | ||
| 60 | Sediments | Sampling of sediments from surface waters Regulated area: Sampling |
PP-17-4 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; Vyhláška č. 257/2009 Sb.; Vyhláška č. 273/2021 Sb.) | ||
| 61 | Hydrobiological material | Sampling of hydrobiological material Regulated area: Sampling |
PP-17-5 (ČSN 75 7701; ČSN 75 7712; ČSN 75 7717; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 10870; ČSN EN 13946; ČSN EN 16698; SOP B-1; SOP B-2; SOP B-3; SOP B-4; SOP B-5; SOP B-6; SOP B-21) | ||
| 62 | Soils | Sampling of soils Regulated area: Sampling |
PP-17-6 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN EN ISO 5667-14, ČSN EN ISO 5667-15, Vyhláška č. 275/1998 Sb.) | ||
| 63 | Sludge (sludge, sediment, sand, soil) | Sampling of sewage and water treatment sludge Regulated area: Sampling |
PP-17-7 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; Vyhláška č. 244/2021 Sb.; Vyhláška č. 273/2021 Sb.; Vyhláška č. 445/2022 Sb.) | ||
Reference standards (162)
EPA 547
EPA Method 1694
EPA Method 535
EPA Method 539
EPA Method 557
EPA Method 8041A
EPA Method 8260
Manuál firmy MERCK
Návod firmy HACH
PP-17-1
PP-17-2
PP-17-3
PP-17-4
PP-17-5
PP-17-6
PP-17-7
SOP B-1
SOP B-11-A
SOP B-12-A
SOP B-13-A
SOP B-2
SOP B-21
SOP B-3
SOP B-4
SOP B-5
SOP B-6
SOP B-7-A
SOP B-9-A
SOP O-13a-A
SOP O-13a-B
SOP O-14-A
SOP O-15-A
SOP O-16-A
SOP O-16-B
SOP O-16-C
SOP O-17-A
SOP O-19-A
SOP O-19-B
SOP O-19-C
SOP O-2c-A
SOP O-2c-B
SOP O-8a-A
SOP O-8a-B
SOP O-9a-B
SOP O-9a-C
SOP Z-10b-A
SOP Z-11b-A
SOP Z-12c-A
SOP Z-13c-A
SOP Z-14e-A
SOP Z-16c-A
SOP Z-17c-A
SOP Z-18d-A
SOP Z-19c-A
SOP Z-1a-A
SOP Z-20e-A
SOP Z-21b-A
SOP Z-22a-A
SOP Z-23b-A
SOP Z-26a-A
SOP Z-27a-A
SOP Z-28b-A
SOP Z-2a-A
SOP Z-33-B
SOP Z-39a-A
SOP Z-4a-A
SOP Z-5a-A
SOP Z-6a-A
SOP Z-7a-A
SOP Z-7b-A
SOP Z-8c-A
SOP Z-9b-A
TNV 75 7055
Vyhláška č. 238/2011 Sb.
Vyhláška č. 244/2021 Sb.
Vyhláška č. 252/2004 Sb.
Vyhláška č. 257/2009 Sb.
Vyhláška č. 273/2021 Sb.
Vyhláška č. 275/1998 Sb.
Vyhláška č. 445/2022 Sb.
ČSN 75 7315
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7350
ČSN 75 7360
ČSN 75 7367
ČSN 75 7701
ČSN 75 7712
ČSN 75 7713
ČSN 75 7714
ČSN 75 7715
ČSN 75 7716
ČSN 75 7717
ČSN 75 7835
ČSN EN 12673
ČSN EN 13946
ČSN EN 14039
ČSN EN 14184
ČSN EN 14407
ČSN EN 15110
ČSN EN 15204
ČSN EN 15460
ČSN EN 15708
ČSN EN 15934
ČSN EN 15935
ČSN EN 16698
ČSN EN 17136
ČSN EN 17322
ČSN EN 1899-2
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 10870
ČSN EN ISO 11732
ČSN EN ISO 12010
ČSN EN ISO 13395
ČSN EN ISO 14403-2
ČSN EN ISO 15680
ČSN EN ISO 15681-2
ČSN EN ISO 15682
ČSN EN ISO 16588
ČSN EN ISO 16703
ČSN EN ISO 17289
ČSN EN ISO 18856
ČSN EN ISO 18857-1
ČSN EN ISO 19458
ČSN EN ISO 22032
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-16
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6468
ČSN EN ISO 7027-1
ČSN EN ISO 7027-2
ČSN EN ISO 7393-2
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-2
ČSN EN ISO 9377-2
ČSN EN ISO 9963-1
ČSN ISO 10260
ČSN ISO 10523
ČSN ISO 15705
ČSN ISO 20179
ČSN ISO 21458
ČSN ISO 22743
ČSN ISO 24293
ČSN ISO 25101
ČSN ISO 29441
ČSN ISO 5667-10
ČSN ISO 5667-12
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6059
ČSN P ISO/TS 28581