🇨🇿 Brněnské vodárny a kanalizace, a.s. PL

ČIA 1160 • Modřice, Czech Republic • 119 methods

Water & wastewaterMicrobiologyEnvironment

Brněnské vodárny a kanalizace, a.s. is a laboratory accredited by ČIA under number 1160 (Modřice, Czech Republic). Its accreditation scope covers 119 test methods in the following areas: Water & wastewater, Microbiology, Environment. Test objects include: Drinking, surface water, Waste, drinking, surface water, Sludge, Drinking, surface, swimming pool water.

At a glance

  • Accreditation number: ČIA 1160
  • Methods in scope: 119
  • Types of test objects: 18
  • City: Modřice, Czech Republic
  • Valid until: 12-06-2030
Accreditation number
1160
Accreditation body
ČIA
Address
Chrlická 552, 664 42 Modřice
City
Modřice, Czech Republic
Division
Dział Kontroli Jakości
Valid until
12-06-2030

What this laboratory tests (18)

Laboratory sections (2)

Laboratory locations

Certificate information

Certificate date
12.06.2025

Accreditation scope — test methods (119)

No. Test object Methodology / Parameters Technique Reference document
Brno - Modřice WWTP Laboratory
1 Waste, drinking, surface, swimming pool water Determination of pH by potentiometry
Regulated area: Tests
SOP/M-01 (ČSN ISO 10523)
2 Sludge Determination of pH by potentiometry
Regulated area: Tests
SOP/M-01A (ČSN EN 12176:1999)
3 Waste, drinking, surface water Determination of conductivity
Regulated area: Tests
SOP/M-02 (ČSN EN 27888)
4 Drinking, surface water Determination of colour by spectrophotometry
Regulated area: Tests
SOP/M-03 (ČSN EN ISO 7887)
5 Drinking, surface, swimming pool water Determination of turbidity by nephelometry
Regulated area: Tests
SOP/M-04 (ČSN EN ISO 7027-1)
6 Waste, drinking, surface water Determination of dissolved solids (RL), loss on ignition, dissolved inorganic salts (RAS) by gravimetry and calculation of dissolved solids, loss on ignition and residue on ignition from measured values
Regulated area: Tests
SOP/M-05 (ČSN 75 7346; ČSN 75 7347; ČSN EN 872; ČSN 75 7350)
7 Sludge Determination of dissolved solids (RL), loss on ignition by gravimetry and residue on ignition by calculation from measured values
Regulated area: Tests
SOP/M-05A (ČSN EN 12879:2001; ČSN EN 12880)
8 Waste, drinking, surface water Determination of suspended solids (NL) and loss on ignition by gravimetry
Regulated area: Tests
SOP/M-06 (ČSN EN 872; ČSN 75 7350)
9 Sludge Determination of suspended solids (NL) and loss on ignition by gravimetry
Regulated area: Tests
SOP/M-06A (Sedláček M. a kol: Metody rozboru kalů a pevných odpadů, 1978, str. 408-414)
10 Waste, surface water Determination of total solids – dry matter, loss on ignition by gravimetry
Regulated area: Tests
SOP/M-07 (Horáková M. a kol.: Chemické a fyzikální metody analýzy vod, 1986, str. 63-74)
11 Sludge Determination of total solids – dry matter, loss on ignition by gravimetry
Regulated area: Tests
SOP/M-07A (ČSN EN 12879:2001; ČSN EN 12880)
12 Waste, drinking, surface water Determination of biochemical oxygen demand (BOD5) by the standard dilution method with oxygen electrode measurement
Regulated area: Tests
SOP/M-08 (ČSN EN ISO 5815-1; ČSN EN 1899-2)
13 Waste, surface water Determination of chemical oxygen demand with potassium dichromate (CODCr) by titrimetric method
Regulated area: Tests
SOP/M-09 (ČSN ISO 6060)
14 Waste, drinking, surface water Determination of chemical oxygen demand with potassium dichromate (CODCr) by semi-micro method spectrophotometrically with Merck kit
Regulated area: Tests
SOP/M-10 (ČSN ISO 15705; Návod firmy Merck)
15 Waste, drinking, surface water Determination of acid neutralizing capacity (ANC8.3; ANC4.5) by titrimetric method
Regulated area: Tests
SOP/M-11 (ČSN EN ISO 9963-1)
16 Drinking, surface water Determination of the sum of calcium and magnesium (Ca + Mg) by EDTA titrimetric method
Regulated area: Tests
SOP/M-12 (ČSN ISO 6059)
17 Waste, drinking, surface water Determination of anionic surfactants by flow analysis with spectrophotometric detection
Regulated area: Tests
SOP/M-13 (ČSN ISO 16265)
18 Waste, drinking, surface water Argentometric titrimetric determination of chloride (Cl-)
Regulated area: Tests
SOP/M-14 (ČSN ISO 9297)
19 Waste, drinking, surface water Determination of sulphate (SO42-) with barium perchlorate by titrimetric method
Regulated area: Tests
SOP/M-15 (Fadrus H.: Sborník Hydrochemie - Kritická studie analytického stanovení síranů, 1986, str. 12)
20 Waste, drinking, surface, swimming pool water Determination of nitrate (NO3-) by spectrophotometry and calculation of nitrate nitrogen (N-NO3-) from measured values
Regulated area: Tests
SOP/M-16 (ČSN ISO 7890-3)
21 Waste, drinking, surface water Determination of nitrite (NO2-) by spectrophotometry and calculation of nitrite nitrogen (N-NO2-) from measured values
Regulated area: Tests
SOP/M-17 (ČSN EN 26777)
22 Waste, drinking, surface water Determination of ammonium (NH4+) by spectrophotometry and calculation of ammonia nitrogen (N-NH4+) from measured values
Regulated area: Tests
SOP/M-18 (ČSN ISO 7150-1)
23 Waste, drinking, surface water Determination of nitrate, nitrite, ammonium, phosphate, total phosphorus by flow analysis with spectrophotometric detection and calculation of nitrate, nitrite, ammonia and inorganic nitrogen and phosphate phosphorus from measured values
Regulated area: Tests
SOP/M-19 (ČSN EN ISO 13395; ČSN EN ISO 11732; ČSN EN ISO 15681-2)
24 Swimming pool water Determination of nitrate (NO3-) by flow analysis with spectrophotometric detection
Regulated area: Tests
SOP/M-19B (ČSN EN ISO 13395)
25 Sludge Determination of total phosphorus by flow analysis with spectrophotometric detection
Regulated area: Tests
SOP/M-19A (ČSN EN ISO 15681-2)
26 Waste, surface water Determination of total nitrogen by TOC/TN analyser and calculation of organic and ammonia nitrogen from measured values (Kjeldahl N)
Regulated area: Tests
SOP/M-21 (ČSN EN ISO 20236)
27 Drinking water Determination of total nitrogen by TOC/TN analyser
Regulated area: Tests
SOP/M-21A (ČSN EN ISO 20236)
28 Waste, drinking, surface water Determination of total phosphorus, phosphate by spectrophotometry and calculation of phosphate phosphorus from measured values
Regulated area: Tests
SOP/M-22 (ČSN EN ISO 6878)
29 Sludge Determination of total phosphorus by spectrophotometry
Regulated area: Tests
SOP/M-22A (ČSN EN ISO 6878; ČSN EN 13346:2001)
30 Waste, drinking, surface water Determination of extractable substances and non-polar extractable substances by infrared spectroscopy
Regulated area: Tests
SOP/M-24 (ČSN 75 7505:1998; ČSN 75 7506)
31 Waste, drinking, surface water Determination of metals by flame AAS
Cobalt (Co) Nickel (Ni) Copper (Cu) Zinc (Zn) Cadmium (Cd) Lead (Pb) Chromium (Cr) Silver (Ag) Calcium (Ca) Magnesium (Mg) Sodium (Na) Potassium (K) Iron (Fe) Manganese (Mn) Barium (Ba) Vanadium (V)
Regulated area: Tests
SOP/M-25 (ČSN ISO 8288; ČSN EN 1233; ČSN 75 740; ČSN ISO 7980; ČSN 75 7385; ČSN ISO 9964-3; TNV 75 7408)
32 Sludge Determination of metals by flame AAS
Cobalt (Co) Nickel (Ni) Copper (Cu) Zinc (Zn) Cadmium (Cd) Lead (Pb) Chromium (Cr) Silver (Ag) Calcium (Ca) Magnesium (Mg) Sodium (Na) Potassium (K) Iron (Fe) Manganese (Mn) Barium (Ba) Vanadium (V)
Regulated area: Tests
SOP/M-25A (ČSN ISO 8288; ČSN EN 1233; ČSN 75 7400; ČSN ISO 7980; ČSN 75 7385; ČSN ISO 9964-3; TNV 75 7408)
33 Waste, drinking, surface water Determination of metals by electrothermal AAS
Arsenic (As) Nickel (Ni) Copper (Cu) Cadmium (Cd) Lead (Pb) Chromium (Cr) Silver (Ag) Aluminium (Al) Barium (Ba) Beryllium (Be) Vanadium (V) Molybdenum (Mo) Cobalt (Co) Selenium (Se) Antimony (Sb) Tin (Sn) Thallium (Tl)
Regulated area: Tests
SOP/M-26 (ČSN EN ISO 15586; TNV 75 7408; ČSN EN 1233; ČSN 75 7400
34 Sludge Determination of metals by electrothermal AAS
Arsenic (As) Nickel (Ni) Copper (Cu) Cadmium (Cd) Lead (Pb) Chromium (Cr) Silver (Ag) Aluminium (Al) Barium (Ba) Beryllium (Be) Vanadium (V) Molybdenum (Mo) Cobalt (Co) Selenium (Se) Antimony (Sb) Tin (Sn) Thallium (Tl)
Regulated area: Tests
SOP/M-26A (ČSN EN ISO 15586; TNV 75 7408; ČSN EN 1233; ČSN 75 7400)
35 Waste, drinking, surface water and sludge Determination of Hg by a dedicated mercury analyser
Regulated area: Tests
SOP/M-27 (ČSN 75 7440)
36 Waste, drinking, surface water Determination of metals by ICP-OES
Calcium (Ca) Magnesium (Mg) Sodium (Na) Potassium (K) Iron (Fe) Manganese (Mn) Aluminium (Al) Vanadium (V) Cobalt (Co) Barium (Ba) Boron (B)
Regulated area: Tests
SOP/M-28 (ČSN EN ISO 11885; ČSN EN ISO 15587-1; ČSN EN ISO 15587-2)
37 Sludge Determination of metals by ICP-OES
Calcium (Ca) Magnesium (Mg) Sodium (Na) Potassium (K) Iron (Fe) Manganese (Mn) Vanadium (V) Cobalt (Co) Arsenic (As)
Regulated area: Tests
SOP/M-28A (ČSN EN ISO 11885)
38 Waste and drinking water Determination of metals by ICP-OES
Copper (Cu) Lead (Pb) Zinc (Zn) Cadmium (Cd) Chromium (Cr) Nickel (Ni)
Regulated area: Tests
SOP/M-29 (ČSN EN ISO 11885; ČSN EN ISO 15587-1; ČSN EN ISO 15587-2)
39 Sludge Determination of metals by ICP-OES
Copper (Cu) Lead (Pb) Zinc (Zn) Cadmium (Cd) Chromium (Cr) Nickel (Ni) Arsenic (As)
Regulated area: Tests
SOP/M-29A (ČSN EN ISO 11885)
40 Waste, drinking, surface water Determination of sulphate (SO42-) by flow analysis with spectrophotometric detection
Regulated area: Tests
SOP/M-31 (ČSN ISO 22743)
41 Waste water Determination of total fats and oils by gravimetry
Regulated area: Tests
SOP/M-32 (ČSN 75 7509)
42 Waste water Determination of volatile fatty acids C1-C6 by titrimetric method
Regulated area: Tests
SOP/M-33 (DIN 38405 - DEV H21)
43 Sludge Determination of volatile fatty acids C1-C6 by titrimetric method
Regulated area: Tests
SOP/M-33A (DIN 38405 - DEV H21)
44 Waste, drinking, surface water Determination of adsorbable organically bound halogens (AOX) by coulometry
Regulated area: Tests
SOP/M-34 (ČSN EN ISO 9562)
45 Sludge Determination of adsorbable organically bound halogens (AOX) by coulometry
Regulated area: Tests
SOP/M-34A (ČSN EN ISO 9562; ČSN EN 16166)
46 Waste, drinking, surface, swimming pool water Determination of total organic carbon (TOC) and dissolved organic carbon (DOC) by TOC/TN analyser
Regulated area: Tests
SOP/M-35 (ČSN EN 1484)
47 Waste, drinking, surface, swimming pool water Determination of temperature
Regulated area: Tests
SOP/M-36 (ČSN 75 7342)
48 Drinking, surface water Determination of chemical oxygen demand with potassium permanganate (CODMn) by titrimetric method
Regulated area: Tests
SOP/M-37 (ČSN EN ISO 8467)
49 Drinking, surface water Determination of absorbance at 254 nm by spectrophotometry
Regulated area: Tests
SOP/M-38 (ČSN 75 7360)
50 Drinking, surface, swimming pool water Determination of free and total chlorine (Cl2) colorimetrically with Hach kit and calculation of combined chlorine from measured values
Regulated area: Tests
SOP/M-39 (ČSN EN ISO 7393-2; Návod firmy Hach)
51 Drinking, surface water Determination of humic substances by spectrophotometry
Regulated area: Tests
SOP/M-40 (ČSN 75 7536)
52 Waste water, drinking and surface water Determination of volatile organic compounds (VOC) by GC/MS - static headspace
1,2-dichloroethane benzene o,m,p-xylene toluene tetrachloromethane tetrachloroethene ethylbenzene trichloroethene trichloromethane dichloromethane chlorobenzene cis-1,2-dichloroethene trans-1,2-dichloroethene sum of o,m,p-dichlorobenzene styrene 1,1-dichloroethene vinyl chloride bromodichloromethane tribromomethane dibromochloromethane
trihalomethanes (sum of trichloromethane, bromodichloromethane, tribromomethane and dibromochloromethane) (calculated)
Regulated area: Tests
SOP/M-42 (ČSN EN ISO 10301)
53 Waste, drinking, surface water Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with fluorescence detection and calculation of the sum of PAH from measured values
fluoranthene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene benzo(g,h,i)perylene indeno(1,2,3-c,d)pyrene
sum of PAH (calculated)
Regulated area: Tests
SOP/M-43 (ČSN EN ISO 17993)
54 Sludge Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with fluorescence detection and calculation of the sum of PAH from measured values
fluoranthene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene benzo(g,h,i)perylene indeno(1,2,3-c,d)pyrene anthracene benz(a)anthracene phenanthrene chrysene naphthalene pyrene
sum of PAH (calculated)
Regulated area: Tests
SOP/M-43A (ČSN EN 17503)
55 Waste, drinking, surface water Determination of polychlorinated biphenyls (PCB) by GC/MS and calculation of the sum of PCB from measured values
PCB congener 28 PCB congener 52 PCB congener 101 PCB congener 138 PCB congener 153 PCB congener 180
sum of PCB (calculated)
Regulated area: Tests
SOP/M-44 (ČSN EN ISO 6468)
56 Sludge Determination of polychlorinated biphenyls (PCB) by GC/MS and calculation of the sum of PCB from measured values
PCB congener 28 PCB congener 52 PCB congener 101 PCB congener 118 PCB congener 138 PCB congener 153 PCB congener 180
sum of PCB (calculated)
Regulated area: Tests
SOP/M-44A (ČSN EN ISO 6468; ČSN EN 17322)
57 Drinking, surface water Determination of organochlorine pesticides (OCP) by GC/MS and calculation of the sum of OCP from measured values
aldrin dieldrin endrin alpha-endosulfan trifluralin gamma-HCH (lindane) hexachlorobenzene heptachlor p,p'-methoxychlor p,p'-DDD p,p'-DDE p,p'-DDT cis-heptachlor epoxide trans-heptachlor epoxide
sum of OCP (calculated)
Regulated area: Tests
SOP/M-46 (ČSN EN ISO 6468)
58 Waste, drinking, surface water Determination of hydrocarbons C10-C40 by GC/FID
Regulated area: Tests
SOP/M-48 (ČSN EN ISO 9377-2)
59 Sludge Determination of hydrocarbons C10-C40 by GC/FID
Regulated area: Tests
SOP/M-48A (ČSN EN 14039)
60 Drinking, surface and swimming pool water Determination of anions by ion chromatography with conductivity detector
fluorides (F-) chlorides (Cl-) nitrites (NO2-) bromides (Br-) nitrates (NO3-) phosphates (PO43-) sulphates (SO42-) chlorites (ClO2-) bromates (BrO3-) chlorates (ClO3-)
Regulated area: Tests
SOP/M-51 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061)
61 Drinking, surface water Determination of microcystin-LR by HPLC with UV detector
Regulated area: Tests
SOP/M-53 (ČSN ISO 20179)
62 Drinking, surface water Enumeration of intestinal enterococci by membrane filtration
Regulated area: Tests
ČSN EN ISO 7899-2
63 Drinking, surface, swimming pool water Enumeration of coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
ČSN EN ISO 9308-1
64 Drinking, surface, swimming pool water Enumeration of culturable microorganisms by inoculation in a nutrient agar culture medium at 22 °C and 36 °C
Regulated area: Tests
ČSN EN ISO 6222
65 Drinking, surface water Determination of bioseston by microscopy
Regulated area: Tests
ČSN 75 7712
66 Drinking, surface water Determination of abioseston by microscopy
Regulated area: Tests
ČSN 75 7713
67 Drinking, surface water Enumeration of Escherichia coli and thermotolerant coliform bacteria by membrane filtration
Regulated area: Tests
ČSN 75 7835
68 Drinking, surface water Enumeration of Clostridium perfringens (including spores) by membrane filtration
Regulated area: Tests
SOP/M-80 (Vyhláška č. 70/2018 Sb., příloha č. 6)
69 Drinking, surface water Enumeration of coliform bacteria by membrane filtration
Regulated area: Tests
ČSN 75 7837
70 Drinking, bottled, swimming pool water Enumeration of Pseudomonas aeruginosa by membrane filtration
Regulated area: Tests
SOP/M-83 (ČSN EN ISO 16266)
71 Swimming pool, hot water Enumeration of Legionella sp. by membrane filtration
Regulated area: Tests
ČSN EN ISO 11731
72 Swimming pool water Enumeration of Staphylococcus aureus by membrane filtration
Regulated area: Tests
SOP/M-85 (ČSN EN ISO 6888-1)
73 Drinking, surface water Enumeration of Clostridium perfringens (including spores) by membrane filtration
Regulated area: Tests
ČSN EN ISO 14189
74 Waste water Sampling of waste water - manual sampling - sampling with automatic samplers
Regulated area: Sampling
SPP/M-01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14
75 Sludge Sampling of sludge
Regulated area: Sampling
SPP/M-02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15)
76 Surface water Sampling of surface water
Regulated area: Sampling
SPP/M-03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
77 Drinking water, raw water Sampling of drinking water - manual sampling - sampling with a sampling pump
Regulated area: Sampling
SPP/M-04 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
78 Swimming pool water Sampling of swimming pool water
Regulated area: Sampling
SPP/M-05 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 238/2011 Sb.)
Švařec WTP Laboratory
79 Waste, drinking, surface, swimming pool water Determination of pH by potentiometry
Regulated area: Tests
SOP/M-01 (ČSN ISO 10523)
80 Waste, drinking, surface water Determination of conductivity
Regulated area: Tests
SOP/M-02 (ČSN EN 27888)
81 Drinking, surface water Determination of colour by spectrophotometry
Regulated area: Tests
SOP/M-03 (ČSN EN ISO 7887)
82 Drinking, surface, swimming pool water Determination of turbidity by nephelometry
Regulated area: Tests
SOP/M-04 (ČSN EN ISO 7027-1)
83 Drinking, surface water Determination of dissolved solids (RL) by gravimetry
Regulated area: Tests
SOP/M-05B (ČSN 75 7346)
84 Waste, drinking, surface water Determination of acid neutralizing capacity (ANC8.3; ANC4.5) by titrimetric method
Regulated area: Tests
SOP/M-11 (ČSN EN ISO 9963-1)
85 Drinking, surface water Determination of the sum of calcium and magnesium (Ca + Mg) by EDTA titrimetric method
Regulated area: Tests
SOP/M-12 (ČSN ISO 6059)
86 Waste, drinking, surface water Argentometric titrimetric determination of chloride (Cl-)
Regulated area: Tests
SOP/M-14 (ČSN ISO 9297)
87 Waste, drinking, surface water Determination of sulphate (SO42-) with barium perchlorate by titrimetric method
Regulated area: Tests
SOP/M-15 (Fadrus H.: Sborník Hydrochemie - Kritická studie analytického stanovení síranů, 1986, str. 12)
88 Waste, drinking, surface, swimming pool water Determination of nitrate (NO3-) by spectrophotometry and calculation of nitrate nitrogen (N-NO3-) from measured values
Regulated area: Tests
SOP/M-16 (ČSN ISO 7890-3)
89 Waste, drinking, surface water Determination of nitrite (NO2-) by spectrophotometry and calculation of nitrite nitrogen (N-NO2-) from measured values
Regulated area: Tests
SOP/M-17 (ČSN EN 26777)
90 Waste, drinking, surface water Determination of ammonium (NH4+) by spectrophotometry and calculation of ammonia nitrogen (N-NH4+) from measured values
Regulated area: Tests
SOP/M-18 (ČSN ISO 7150-1)
91 Drinking, surface water Determination of phosphate (PO43-) by spectrophotometry
Regulated area: Tests
SOP/M-22B (ČSN EN ISO 6878)
92 Waste, drinking, surface, swimming pool water Determination of temperature
Regulated area: Tests
SOP/M-36 (ČSN 75 7342)
93 Drinking, surface water Determination of chemical oxygen demand with potassium permanganate (CODMn) by titrimetric method
Regulated area: Tests
SOP/M-37 (ČSN EN ISO 8467)
94 Drinking, surface water Determination of absorbance at 254 nm by spectrophotometry
Regulated area: Tests
SOP/M-38 (ČSN 75 7360)
95 Drinking, surface, swimming pool water Determination of free and total chlorine (Cl2) colorimetrically with Hach kit and calculation of combined chlorine from measured values
Regulated area: Tests
SOP/M-39 (ČSN EN ISO 7393-2; Návod firmy Hach)
96 Drinking, surface and swimming pool water Determination of anions by ion chromatography with conductivity detector
fluorides (F-) chlorides (Cl-) nitrites (NO2-) bromides (Br-) nitrates (NO3-) phosphates (PO43-) sulphates (SO42-) chlorites (ClO2-) bromates (BrO3-) chlorates (ClO3-)
Regulated area: Tests
SOP/M-51 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061)
97 Drinking, surface water Determination of microcystin by spectrophotometry with VIDIA kits
Regulated area: Tests
SOP/M-52 (Návod firmy VIDIA)
98 Drinking, surface water Quantification of planktonic cyanobacteria by microscopy
Regulated area: Tests
ČSN 75 7717
99 Surface water Determination of chlorophyll-a and phaeopigment concentration by spectrophotometry
Regulated area: Tests
ČSN ISO 10260
100 Drinking, surface, waste water Determination of chemical oxygen demand with potassium dichromate (CODCr) by semi-micro method spectrophotometrically with Hach kit
Regulated area: Tests
SOP/M-58 (ČSN ISO 15705; Návod firmy Hach)
101 Drinking, surface, swimming pool water Determination of oxidation-reduction potential (ORP) by potentiometry
Regulated area: Tests
SOP/M-59 (ČSN 75 7367)
102 Drinking water Determination of odour and taste of drinking water by indicative sensory analysis
Regulated area: Tests
SOP/M-60 (ČSN 75 7340; ČSN EN 1622)
103 Drinking, surface water Determination of aluminium (Al) by spectrophotometry
Regulated area: Tests
SOP/M-61 (ČSN ISO 10566)
104 Drinking, surface water Determination of manganese (Mn) by spectrophotometry
Regulated area: Tests
SOP/M-62 (ČSN ISO 6333)
105 Drinking, surface water Determination of dissolved iron (Fe) by spectrophotometry
Regulated area: Tests
SOP/M-63 (ČSN ISO 6332)
106 Drinking, surface water Determination of calcium (Ca) by EDTA titrimetric method and calculation of magnesium (Mg) from measured values
Regulated area: Tests
SOP/M-64 (ČSN ISO 6058)
107 Drinking, surface, waste water Determination of boron (B) by spectrophotometry
Regulated area: Tests
SOP/M-65 (ČSN ISO 9390)
108 Drinking, surface water Enumeration of intestinal enterococci by membrane filtration
Regulated area: Tests
ČSN EN ISO 7899-2
109 Drinking, surface, swimming pool water Enumeration of coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
ČSN EN ISO 9308-1
110 Drinking, surface, swimming pool water Enumeration of culturable microorganisms by inoculation in a nutrient agar culture medium at 22 °C and 36 °C
Regulated area: Tests
ČSN EN ISO 6222
111 Drinking, surface water Determination of bioseston by microscopy
Regulated area: Tests
ČSN 75 7712
112 Drinking, surface water Determination of abioseston by microscopy
Regulated area: Tests
ČSN 75 7713
113 Drinking, surface water Enumeration of Escherichia coli and thermotolerant coliform bacteria by membrane filtration
Regulated area: Tests
ČSN 75 7835
114 Drinking, surface water Enumeration of Clostridium perfringens (including spores) by membrane filtration
Regulated area: Tests
SOP/M-80 (Vyhláška č. 70/2018 Sb., příloha č. 6)
115 Drinking, surface water Enumeration of coliform bacteria by membrane filtration
Regulated area: Tests
ČSN 75 7837
116 Drinking, surface water Enumeration of Clostridium perfringens (including spores) by membrane filtration
Regulated area: Tests
ČSN EN ISO 14189
117 Surface water Sampling of surface water
Regulated area: Sampling
SPP/M-03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
118 Drinking water, raw water Sampling of drinking water - manual sampling
Regulated area: Sampling
SPP/M-04 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
119 Swimming pool water Sampling of swimming pool water
Regulated area: Sampling
SPP/M-05 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 238/2011 Sb.)

Reference standards (185)

DIN 38405 - DEV H21
Fadrus H.: Sborník Hydrochemie - Kritická studie analytického stanovení síranů, 1986, str. 12
Horáková M. a kol.: Chemické a fyzikální metody analýzy vod, 1986, str. 63-74
Návod firmy Hach
Návod firmy Merck
Návod firmy VIDIA
SOP/M-01
SOP/M-01A
SOP/M-02
SOP/M-03
SOP/M-04
SOP/M-05
SOP/M-05A
SOP/M-05B
SOP/M-06
SOP/M-06A
SOP/M-07
SOP/M-07A
SOP/M-08
SOP/M-09
SOP/M-10
SOP/M-11
SOP/M-12
SOP/M-13
SOP/M-14
SOP/M-15
SOP/M-16
SOP/M-17
SOP/M-18
SOP/M-19
SOP/M-19A
SOP/M-19B
SOP/M-21
SOP/M-21A
SOP/M-22
SOP/M-22A
SOP/M-22B
SOP/M-24
SOP/M-25
SOP/M-25A
SOP/M-26
SOP/M-26A
SOP/M-27
SOP/M-28
SOP/M-28A
SOP/M-29
SOP/M-29A
SOP/M-31
SOP/M-32
SOP/M-33
SOP/M-33A
SOP/M-34
SOP/M-34A
SOP/M-35
SOP/M-36
SOP/M-37
SOP/M-38
SOP/M-39
SOP/M-40
SOP/M-42
SOP/M-43
SOP/M-43A
SOP/M-44
SOP/M-44A
SOP/M-46
SOP/M-48
SOP/M-48A
SOP/M-51
SOP/M-52
SOP/M-53
SOP/M-58
SOP/M-59
SOP/M-60
SOP/M-61
SOP/M-62
SOP/M-63
SOP/M-64
SOP/M-65
SOP/M-80
SOP/M-83
SOP/M-85
SPP/M-01
SPP/M-02
SPP/M-03
SPP/M-04
SPP/M-05
Sedláček M. a kol: Metody rozboru kalů a pevných odpadů, 1978, str. 408-414
TNV 75 7408
Vyhláška č. 238/2011 Sb.
Vyhláška č. 70/2018 Sb., příloha č. 6
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7350
ČSN 75 7360
ČSN 75 7367
ČSN 75 7385
ČSN 75 740
ČSN 75 7400
ČSN 75 7440
ČSN 75 7505:1998
ČSN 75 7506
ČSN 75 7509
ČSN 75 7536
ČSN 75 7712
ČSN 75 7713
ČSN 75 7717
ČSN 75 7835
ČSN 75 7837
ČSN EN 12176:1999
ČSN EN 1233
ČSN EN 12879:2001
ČSN EN 12880
ČSN EN 13346:2001
ČSN EN 14039
ČSN EN 1484
ČSN EN 16166
ČSN EN 1622
ČSN EN 17322
ČSN EN 17503
ČSN EN 1899-2
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 10301
ČSN EN ISO 10304-1
ČSN EN ISO 10304-4
ČSN EN ISO 11731
ČSN EN ISO 11732
ČSN EN ISO 11885
ČSN EN ISO 13395
ČSN EN ISO 14189
ČSN EN ISO 15061
ČSN EN ISO 15586
ČSN EN ISO 15587-1
ČSN EN ISO 15587-2
ČSN EN ISO 15681-2
ČSN EN ISO 16266
ČSN EN ISO 17993
ČSN EN ISO 19458
ČSN EN ISO 20236
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6468
ČSN EN ISO 6878
ČSN EN ISO 6888-1
ČSN EN ISO 7027-1
ČSN EN ISO 7393-2
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9377-2
ČSN EN ISO 9562
ČSN EN ISO 9963-1
ČSN ISO 10260
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 15705
ČSN ISO 16265
ČSN ISO 20179
ČSN ISO 22743
ČSN ISO 5667-10
ČSN ISO 5667-11
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6060
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 7980
ČSN ISO 8288
ČSN ISO 9297
ČSN ISO 9390
ČSN ISO 9964-3

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1160