🇨🇿 ČEVAK a.s. PL

ČIA 1146 • České Budějovice, Czech Republic • 179 methods

Water & wastewaterMicrobiologyEnvironment

ČEVAK a.s. is a laboratory accredited by ČIA under number 1146 (České Budějovice, Czech Republic). Its accreditation scope covers 179 test methods in the following areas: Water & wastewater, Microbiology, Environment. Test objects include: Drinking, raw water, Drinking, raw, ground, surface water, Drinking, surface, ground water, Drinking, surface, raw water.

At a glance

  • Accreditation number: ČIA 1146
  • Methods in scope: 179
  • Types of test objects: 40
  • City: České Budějovice, Czech Republic
  • Valid until: 27-02-2030
Accreditation number
1146
Accreditation body
ČIA
Address
Severní 2264/8, 370 10 České Budějovice
City
České Budějovice, Czech Republic
Division
Laboratorium
Valid until
27-02-2030

What this laboratory tests (40)

Laboratory sections (5)

Laboratory locations

Certificate information

Certificate date
15.07.2026

Accreditation scope — test methods (179)

No. Test object Methodology / Parameters Technique Reference document
P1 České Budějovice
1 Drinking, raw, ground, surface, hot water Determination of colour by spectrophotometry
Regulated area: Tests
SOP č. 1 (ČSN EN ISO 7887)
2 Drinking water Determination of threshold odour and taste numbers by sensory analysis
Regulated area: Tests
SOP č. 2 (ČSN EN 1622; ČSN 75 7340)
3 Drinking, raw, ground, surface, hot, pool water Determination of turbidity by nephelometry
Regulated area: Tests
SOP č. 3 (ČSN EN ISO 7027-1)
4 Drinking, raw, ground, surface water Determination of electrical conductivity
Regulated area: Tests
SOP č. 5 (ČSN EN 27888)
5 Drinking, raw, ground, surface, hot, pool water Determination of pH by potentiometry
Regulated area: Tests
SOP č. 6 (ČSN ISO 10523)
6 Drinking, raw, ground, surface water Determination of acid neutralising capacity (ANC) by titration
Regulated area: Tests
SOP č. 7 (ČSN EN ISO 9963-1)
7 Drinking, raw, ground, surface water Determination of base neutralising capacity (BNC) by titration and calculation of forms of carbon dioxide
forms of carbon dioxide (calculated)
Regulated area: Tests
SOP č. 8 (ČSN 75 7372; ČSN 75 7373)
8 Drinking, raw, ground, surface water Determination of calcium and the sum of calcium and magnesium by titration, magnesium by calculation
calcium sum of calcium and magnesium
magnesium (calculated)
Regulated area: Tests
SOP č. 9 (ČSN ISO 6058; ČSN ISO 6059)
9 Drinking, raw, ground, surface water Determination of absorbance at 254 nm by spectrophotometry
Regulated area: Tests
SOP č. 11 (ČSN 75 7360)
10 Raw, ground, surface water Determination of biochemical oxygen demand BOD5 with an optical sensor
Regulated area: Tests
SOP č. 12 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN ISO 17289)
11 Drinking, raw, ground, surface, hot, pool water Determination of chemical oxygen demand by permanganate (CODMn) by titration
Regulated area: Tests
SOP č. 13 (ČSN EN ISO 8467)
12 Raw, ground, surface water Determination of chemical oxygen demand by dichromate (CODCr) by spectrophotometry using a Merck cuvette test
Regulated area: Tests
SOP č. 14 (ČSN ISO 15705; Manuál firmy Merck)
13 Drinking, raw, ground, surface water Determination of chlorides by titration
Regulated area: Tests
SOP č. 18 (EPA 325.3:1982)
14 Drinking, raw, ground, surface water Determination of sulphates by spectrophotometry
Regulated area: Tests
SOP č. 19 (EPA 375.4:1978)
15 Drinking, raw, ground, surface, hot water Determination of total phosphorus and orthophosphates by spectrophotometry and orthophosphate phosphorus by calculation
total phosphorus orthophosphates
orthophosphate phosphorus (calculated)
Regulated area: Tests
SOP č. 20 (ČSN EN ISO 6878)
16 Drinking, raw, ground, surface, pool water Determination of ammonia and ammonium ions by spectrophotometry and ammonium nitrogen by calculation
ammonia ammonium ions
ammonium nitrogen (calculated)
Regulated area: Tests
SOP č. 15A (ČSN ISO 7150-1)
17 Drinking, raw, ground, surface water Determination of nitrites by spectrophotometry and nitrite nitrogen by calculation
nitrite nitrogen (calculated)
Regulated area: Tests
SOP č. 16 (ČSN EN 26777)
18 Drinking, raw, ground, surface, pool water Determination of nitrates by spectrophotometry and nitrate and total inorganic nitrogen by calculation
nitrate nitrogen (calculated), total inorganic nitrogen (calculated)
Regulated area: Tests
SOP č. 17 (ČSN ISO 7890-3)
19 Drinking, raw, ground water Determination of nitrates by direct UV spectrometry and nitrate nitrogen by calculation
nitrate nitrogen (calculated)
Regulated area: Tests
SOP č. 17A (Janoušek I., Fiala J.: Vodní hospodářství 38B, 51:1988)
20 Drinking, raw, ground, surface, pool water Determination of nitrates by spectrophotometry using a Merck cuvette kit and nitrate and total inorganic nitrogen by calculation
nitrate nitrogen (calculated), total inorganic nitrogen (calculated)
Regulated area: Tests
SOP č. 17B (ČSN 75 7455; Manuál firmy Merck)
21 Drinking, raw, ground, surface water Determination of total nitrogen by spectrophotometry using a Merck kit
Regulated area: Tests
SOP č. 25 (Manuál firmy Merck; ČSN EN ISO 11905-1)
22 Drinking, raw, ground, surface water Determination of dried and ignited dissolved solids (DS) by gravimetry
Regulated area: Tests
SOP č. 21 (ČSN 75 7346)
23 Raw, ground, surface water Determination of dried and ignited suspended solids (SS) by gravimetry
Regulated area: Tests
SOP č. 22 (ČSN EN 872; ČSN 75 7350)
24 Sludge Determination of dry matter by gravimetry
Regulated area: Tests
SOP č. 23 (ČSN EN 12880:2021)
25 Drinking, raw, ground, surface water Determination of fluorides by potentiometry (ISE)
Regulated area: Tests
SOP č. 32 (ČSN ISO 10359-1)
26 Drinking, raw, ground, surface water Determination of borates and boron by spectrophotometry
borates boron
Regulated area: Tests
SOP č. 33 (ČSN ISO 9390)
27 Drinking, raw, ground, surface water Determination of iron by spectrophotometry
Regulated area: Tests
SOP č. 36 (ČSN ISO 6332)
28 Drinking, raw, ground, surface water Determination of manganese by spectrophotometry
Regulated area: Tests
SOP č. 37 (ČSN 83 0520-21:1978)
29 Drinking, raw, ground, surface water Determination of aluminium by spectrophotometry
Regulated area: Tests
SOP č. 38 (ČSN ISO 10566)
30 Drinking, raw, ground, surface, waste water Determination of anionic surfactants by spectrophotometry using a Merck cuvette test
Regulated area: Tests
SOP č. 30A (Manuál firmy Merck; ČSN EN 903)
31 Pool water Determination of oxidation-reduction potential (ORP) by potentiometry
Regulated area: Tests
SOP č. 40 (ČSN 75 7367)
32 Pool water Determination of ozone by spectrophotometry using a HACH kit
Regulated area: Tests
SOP č. 41 (Manuál firmy HACH)
33 Drinking, raw, ground, surface, waste, hot water Determination of temperature
Regulated area: Tests
SOP č. 50 (ČSN 75 7342)
34 Drinking, hot, pool water Determination of free and total chlorine by spectrophotometry using a HACH kit and combined chlorine by calculation
free chlorine total chlorine
combined chlorine (calculated)
Regulated area: Tests
SOP č. 51 (Manuál firmy HACH; ČSN EN ISO 7393-2)
35 Drinking, raw, ground, hot, pool water Determination of Escherichia coli and coliform bacteria by the membrane filtration method
Regulated area: Tests
SOP č. 201 (ČSN EN ISO 9308-1)
36 Raw, ground, surface, pool water Determination of thermotolerant coliform bacteria by the membrane filtration method
Regulated area: Tests
SOP č. 202 (ČSN 75 7835)
37 Drinking, raw, ground, surface water Determination of intestinal enterococci by the membrane filtration method
Regulated area: Tests
SOP č. 203 (ČSN EN ISO 7899-2)
38 Drinking, raw, ground, surface, hot, pool water Enumeration of culturable micro-organisms – colony count by inoculation in a nutrient agar medium at 36 °C and 22 °C
at 36 °C at 22 °C
Regulated area: Tests
SOP č. 204 (ČSN EN ISO 6222)
39 Drinking, raw water Determination of the microscopic picture, living and dead organisms, determination of abioseston
living organisms dead organisms abioseston
Regulated area: Tests
SOP č. 207 (ČSN 75 7712; ČSN 75 7713)
40 Hot, pool water Determination of Pseudomonas aeruginosa by the membrane filtration method
Regulated area: Tests
SOP č. 209 (ČSN EN ISO 16266)
41 Hot, pool water Determination of coagulase-positive staphylococci by the membrane filtration method
Regulated area: Tests
SOP č. 210 (ČSN EN ISO 6888-1)
42 Sludge Determination of indicator micro-organisms (thermotolerant coliform bacteria, intestinal enterococci, Salmonella)
thermotolerant coliform bacteria intestinal enterococci Salmonella spp.
Regulated area: Tests
SOP č. 212 (AHEM č. 1/2008)
43 Drinking, hot, pool water Determination of Legionella bacteria by culture
Regulated area: Tests
SOP č. 213 (ČSN EN ISO 11731)
44 Drinking, raw, hot water Sampling of drinking water
Regulated area: Sampling
SOP č. 400 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. č. 252/2004 Sb.)
45 Pool water Sampling of pool water
Regulated area: Sampling
SOP č. 404 (Vyhl. č. 238/2011 Sb.; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
P2 WWTP České Budějovice
46 Drinking, raw, waste water Determination of pH by potentiometry
Regulated area: Tests
SOP 1A (ČSN ISO 10523)
47 Sludge Determination of pH by potentiometry
Regulated area: Tests
SOP 1B (ČSN EN 12176:1999)
48 Waste water Determination of chemical oxygen demand by dichromate (CODCr) by spectrophotometry using a Merck kit
Regulated area: Tests
SOP 2B (ČSN ISO 15705; Manuál firmy Merck)
49 Waste water Determination of biochemical oxygen demand BOD5 with an optical sensor
Regulated area: Tests
SOP 3B (ČSN EN ISO 5815-1; ČSN ISO 17289)
50 Drinking, raw, waste water Determination of dried and ignited suspended solids (SS) by gravimetry
Regulated area: Tests
SOP 4 (ČSN EN 872; ČSN 75 7350)
51 Drinking, raw, waste water Determination of dried and ignited dissolved solids (DS) and DIS by gravimetry
dissolved solids (DS) dissolved inorganic salts (DIS)
Regulated area: Tests
SOP 5 (ČSN 75 7346; ČSN 75 7347)
52 Drinking, raw, waste water Determination of total phosphorus and orthophosphates by spectrophotometry and orthophosphate phosphorus by calculation
total phosphorus orthophosphates
orthophosphate phosphorus (calculated)
Regulated area: Tests
SOP 6 (ČSN EN ISO 6878)
53 Waste water Determination of ammonium nitrogen and ammonium ions by titration after distillation
Regulated area: Tests
SOP 7 (ČSN ISO 5664)
54 Drinking, raw, waste water Determination of nitrates by spectrophotometry and nitrate and total inorganic nitrogen by calculation
nitrate nitrogen (calculated), total inorganic nitrogen (calculated)
Regulated area: Tests
SOP 8 (ČSN ISO 7890-3)
55 Drinking, raw, waste water Determination of nitrites by spectrophotometry and nitrite nitrogen by calculation
nitrite nitrogen (calculated)
Regulated area: Tests
SOP 9 (ČSN EN 26 777)
56 Waste water Determination of total nitrogen by titration after mineralisation
Regulated area: Tests
SOP 10 (ČSN ISO 10048:1996)
57 Drinking, raw, waste water Determination of acid neutralising capacity (ANC) by titration
Regulated area: Tests
SOP 11 (ČSN EN ISO 9963-1)
58 Sludge Determination of dry matter and total solids by gravimetry
Regulated area: Tests
SOP 12 (ČSN EN 15934:2013; ČSN EN 15935)
59 Drinking, raw, waste water Determination of electrical conductivity
Regulated area: Tests
SOP 19 (ČSN EN 27888)
60 Drinking, raw, waste water Determination of iron by spectrophotometry
Regulated area: Tests
SOP 24 (ČSN ISO 6332)
61 Drinking, raw water Determination of manganese by spectrophotometry
Regulated area: Tests
SOP 25 (ČSN 83 0520-21:1978)
62 Drinking, raw, hot, waste water Determination of temperature
Regulated area: Tests
SOP č. 50 (ČSN 75 7342)
63 Drinking, hot, pool water Determination of free and total chlorine by spectrophotometry using a HACH kit and combined chlorine by calculation
free chlorine total chlorine
combined chlorine (calculated)
Regulated area: Tests
SOP č. 51 (Manuál firmy HACH; ČSN EN ISO 7393-2)
64 Sludge Determination of phosphorus by spectrophotometry after aqua regia digestion
Regulated area: Tests
SOP 101 (ČSN EN 13346:2001 metoda B; ČSN EN ISO 6878)
65 Sludge Determination of total nitrogen by the modified Kjeldahl method
Regulated area: Tests
SOP 102 (ČSN ISO 11261)
66 Waste water Determination of chemical oxygen demand by dichromate (CODCr) by spectrophotometry using a HACH cuvette test
Regulated area: Tests
SOP 2C (ČSN ISO 15705; Manuál firmy HACH)
67 Drinking, raw, hot water Sampling of drinking water
Regulated area: Sampling
SOP č. 400 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. č. 252/2004 Sb.)
68 Waste water Sampling of waste water (manual sampling and sampling with an automatic sampler)
Regulated area: Sampling
SOP č. 403 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)
P3 Beroun
69 Drinking, surface, raw water Determination of absorbance at 254 nm by spectrophotometry
Regulated area: Tests
SOP č. 1 (ČSN 75 7360)
70 Drinking, surface, raw, hot, pool water Determination of colour by spectrophotometry
Regulated area: Tests
SOP č. 2 (ČSN EN ISO 7887)
71 Drinking, surface, raw, hot, pool water Determination of turbidity by nephelometry
Regulated area: Tests
SOP č. 3 (ČSN EN ISO 7027-1)
72 Drinking, surface, raw water Determination of electrical conductivity
Regulated area: Tests
SOP č. 4 (ČSN EN 27888)
73 Drinking, surface, raw, waste, hot, pool water Determination of pH by potentiometry
Regulated area: Tests
SOP č. 5 (ČSN ISO 10523)
74 Drinking, surface, raw water Determination of chlorides by titration
Regulated area: Tests
SOP č. 6 (ČSN ISO 9297)
75 Drinking, surface, raw water Determination of dissolved fluorides by spectrophotometry
Regulated area: Tests
SOP č. 7 (TNV 75 7431)
76 Drinking, surface, raw, waste water Determination of nitrites by spectrophotometry and nitrite nitrogen by calculation
nitrite nitrogen (calculated)
Regulated area: Tests
SOP č. 8 (ČSN EN 26777)
77 Drinking, surface, raw, hot, pool, waste water Determination of nitrates by spectrophotometry and nitrate and total inorganic nitrogen by calculation
nitrate nitrogen (calculated), total inorganic nitrogen (calculated)
Regulated area: Tests
SOP č. 9 (ČSN ISO 7890-3)
78 Drinking, surface, raw water Determination of sulphates by titration
Regulated area: Tests
SOP č. 10 (ČSN 75 7477)
79 Drinking, surface, raw, hot, waste water Determination of total phosphorus and orthophosphates by spectrophotometry
total phosphorus orthophosphates
Regulated area: Tests
SOP č. 11 (ČSN EN ISO 6878)
80 Drinking, surface, raw, hot, waste water Determination of total phosphorus using a HACH cuvette test
Regulated area: Tests
SOP č. 11 (ČSN EN ISO 6878; Manuál firmy HACH)
81 Drinking, surface, raw, waste water Determination of ammonium ions by spectrophotometry and ammonium nitrogen by calculation
ammonium nitrogen (calculated)
Regulated area: Tests
SOP č. 12 (ČSN ISO 7150-1)
82 Drinking, surface, raw, waste water Determination of acid neutralising capacity (ANC) by titration
Regulated area: Tests
SOP č. 13 (ČSN EN ISO 9963-1)
83 Drinking, surface, raw, waste water Determination of base neutralising capacity (BNC) by titration
Regulated area: Tests
SOP č. 14 (ČSN 75 7372)
84 Drinking, surface, raw water Determination of manganese by spectrophotometry
Regulated area: Tests
SOP č. 15 (ČSN ISO 6333)
85 Drinking, surface, raw water Determination of calcium by titration
Regulated area: Tests
SOP č. 16 (ČSN ISO 6058)
86 Drinking, surface, raw water Determination of iron by spectrophotometry
Regulated area: Tests
SOP č. 17 (ČSN ISO 6332)
87 Drinking, surface, raw, waste water Determination of total nitrogen by spectrophotometry using a HACH kit
Regulated area: Tests
SOP č. 18 (ČSN EN ISO 11905-1; Manuál firmy HACH)
88 Drinking, surface, raw water Determination of the sum of calcium and magnesium by titration, magnesium by calculation
sum of calcium and magnesium
magnesium (calculated)
Regulated area: Tests
SOP č. 19 (ČSN ISO 6059)
89 Drinking, surface, raw water Determination of chemical oxygen demand by permanganate (CODMn) by titration
Regulated area: Tests
SOP č. 20 (ČSN EN ISO 8467)
90 Drinking, surface, raw, waste water Determination of dissolved solids (DS) and dissolved inorganic salts (DIS) by gravimetry
dissolved solids (DS) dissolved inorganic salts (DIS)
Regulated area: Tests
SOP č. 21 (ČSN 75 7346; ČSN 75 7347)
91 Drinking, surface, raw, waste water Determination of suspended solids (SS) by gravimetry
Regulated area: Tests
SOP č. 22 (ČSN EN 872)
92 Drinking, surface, raw, waste water Determination of chemical oxygen demand by dichromate (CODCr) by spectrophotometry
Regulated area: Tests
SOP č. 23 (ČSN ISO 15705; TNI 75 7521)
93 Drinking, surface, raw, waste water Determination of biochemical oxygen demand BOD5 with an optical sensor
Regulated area: Tests
SOP č. 24 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN ISO 17289)
94 Drinking, surface, raw, hot, pool, waste water Determination of temperature
Regulated area: Tests
SOP č. 25 (ČSN 75 7342)
95 Drinking, surface, raw water Determination of aluminium by spectrophotometry
Regulated area: Tests
SOP č. 26 (ČSN ISO 10566)
96 Drinking, hot, pool water Determination of free and total chlorine by spectrophotometry using a HACH kit and combined chlorine by calculation
free chlorine total chlorine
combined chlorine (calculated)
Regulated area: Tests
SOP č. 27 (Manuál firmy HACH; ČSN EN ISO 7393-2)
97 Drinking, surface, raw, pool water Determination of intestinal enterococci by the membrane filtration method
Regulated area: Tests
SOP č. 28 (ČSN EN ISO 7899-2)
98 Drinking, surface, raw water Biological analysis – determination of living and dead organisms
Regulated area: Tests
SOP č. 29 (ČSN 75 7712)
99 Drinking, surface, raw water Determination of abioseston
Regulated area: Tests
SOP č. 30 (ČSN 75 7713)
100 Drinking, surface, raw, pool water Determination of thermotolerant coliform bacteria and Escherichia coli by the membrane filtration method
Regulated area: Tests
SOP č. 31 (ČSN 75 7835)
101 Drinking, surface, raw, hot, pool water Enumeration of culturable micro-organisms – colony count by inoculation in a nutrient agar medium at 36 °C and 22 °C
at 36 °C at 22 °C
Regulated area: Tests
SOP č. 32 (ČSN EN ISO 6222)
102 Drinking, hot, pool water Determination of Pseudomonas aeruginosa by the membrane filtration method
Regulated area: Tests
SOP č. 33 (ČSN EN ISO 16266)
103 Drinking, surface, raw water Determination of coliform bacteria in non-disinfected water by the membrane filtration method
Regulated area: Tests
SOP č. 34 (ČSN 75 7837)
104 Drinking, surface, raw, hot, pool water Determination of coliform bacteria and Escherichia coli by the Colilert 18/Quanti-Tray method
Regulated area: Tests
SOP č. 35 (ČSN EN ISO 9308-2)
105 Drinking, raw, hot water Sampling of drinking water
Regulated area: Sampling
SOP č. B 1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. č. 252/2004 Sb.)
106 Waste water Sampling of waste water (manual sampling and sampling with an automatic sampler)
Regulated area: Sampling
SOP č. B 2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)
107 Pool water Sampling of pool water
Regulated area: Sampling
SOP č. B 4 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. č. 238/2011 Sb.)
P4 Chrudim
108 Drinking, surface, ground, waste water, liquid sludge Determination of pH by potentiometry
Regulated area: Tests
SOP č. 1 (ČSN ISO 10 523)
109 Drinking, surface, ground water Determination of electrical conductivity
Regulated area: Tests
SOP č. 2 (ČSN EN 27888)
110 Waste, surface, ground water Determination of dissolved oxygen with an optical sensor
Regulated area: Tests
SOP č. 3 (ČSN ISO 17289)
111 Drinking, surface, ground water Determination of acid (ANC) and base (BNC) neutralising capacity by titration
acid neutralising capacity (ANC) base neutralising capacity (BNC)
Regulated area: Tests
SOP č. 4 (ČSN EN ISO 9963-1; ČSN 757372)
112 Drinking, surface, ground water Determination of calcium and the sum of calcium and magnesium by titration and magnesium by calculation
calcium sum of calcium and magnesium
magnesium (calculated)
Regulated area: Tests
SOP č. 5 (ČSN ISO 6058; ČSN ISO 6059)
113 Waste, surface water Determination of ammonium nitrogen and ammonium ions by titration after distillation
Regulated area: Tests
SOP č. 45 (ČSN ISO 5664)
114 Drinking, surface, ground water Determination of ammonium ions by spectrophotometry
Regulated area: Tests
SOP č. 7 (ČSN ISO 7150-1)
115 Drinking, surface, ground water Determination of turbidity by nephelometry
Regulated area: Tests
SOP č. 8 (ČSN EN ISO 7027-1)
116 Drinking, surface, ground, waste water Determination of nitrates by spectrophotometry and nitrate and total inorganic nitrogen by calculation
nitrate nitrogen (calculated), total inorganic nitrogen (calculated)
Regulated area: Tests
SOP č. 9 (ČSN ISO 7890-3)
117 Drinking, surface, ground, waste water Determination of nitrites by spectrophotometry and nitrite nitrogen by calculation
nitrite nitrogen (calculated)
Regulated area: Tests
SOP č. 10 (ČSN EN 26777)
118 Waste, surface water Determination of total nitrogen by spectrophotometry using a Merck kit
Regulated area: Tests
SOP č. 56 (ČSN EN ISO 11905-1; ČSN 75 7455; Manuál firmy Merck)
119 Drinking, surface, ground water Determination of humic substances by spectrophotometry
Regulated area: Tests
SOP č. 23 (ČSN 75 7536)
120 Drinking, surface, ground, waste water Determination of iron by spectrophotometry
Regulated area: Tests
SOP č. 13 (ČSN ISO 6332)
121 Drinking, surface, ground, waste water Determination of manganese by spectrophotometry
Regulated area: Tests
SOP č. 14 (ČSN ISO 6333)
122 Drinking, surface, ground, waste water Determination of aluminium by spectrophotometry
Regulated area: Tests
SOP č. 15 (ČSN ISO 10566)
123 Drinking, surface, ground water Determination of chlorides by titration
Regulated area: Tests
SOP č. 16 (ČSN ISO 9297)
124 Drinking, surface, ground water Determination of sulphates by titration
Regulated area: Tests
SOP č. 17 (ČSN 75 7477)
125 Drinking, surface, ground, waste water Determination of phosphates and total phosphorus after mineralisation by spectrophotometry
phosphates total phosphorus
Regulated area: Tests
SOP č. 18 (ČSN EN ISO 6878)
126 Drinking, surface, ground water Determination of colour by spectrophotometry
Regulated area: Tests
SOP č. 33 (ČSN EN ISO 7887)
127 Surface, waste water Determination of chemical oxygen demand by dichromate (CODCr) by titration
Regulated area: Tests
SOP č. 20 (ČSN ISO 6060)
128 Drinking, surface, ground water Determination of chemical oxygen demand by permanganate (CODMn) by titration
Regulated area: Tests
SOP č. 21 (ČSN EN ISO 8467)
129 Surface, ground, waste water Determination of biochemical oxygen demand BOD5 with an optical sensor
Regulated area: Tests
SOP č. 22 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN ISO 17289)
130 Drinking water Sensory analysis – odour, taste
odour taste
Regulated area: Tests
SOP č. 41 (ČSN EN 1622; ČSN 75 7340)
131 Drinking water Determination of free and total chlorine by spectrophotometry using a HACH kit
free chlorine total chlorine
Regulated area: Tests
SOP č. 24 (Manuál firmy HACH; ČSN EN ISO 7393-2)
132 Waste, surface, ground water Determination of suspended solids (SS) by gravimetry
Regulated area: Tests
SOP č. 25 (ČSN EN 872)
133 Drinking, surface, ground, waste water Determination of dissolved solids (DS) and dissolved inorganic salts (DIS) by gravimetry
dissolved solids (DS) dissolved inorganic salts (DIS)
Regulated area: Tests
SOP č. 26 (ČSN 75 7346; ČSN 75 7347)
134 Drinking, surface, ground, waste water Determination of temperature
Regulated area: Tests
SOP č. 46 (ČSN 75 7342)
135 Drinking, surface, ground water Enumeration of culturable micro-organisms – colony count by inoculation in a nutrient agar medium at 36 °C and 22 °C
at 36 °C at 22 °C
Regulated area: Tests
SOP č. 51 (ČSN EN ISO 6222)
136 Surface, ground water Determination of coliform bacteria in non-disinfected water by the membrane filtration method
Regulated area: Tests
SOP č. 29 (ČSN 75 7837)
137 Drinking, surface, ground water Determination of thermotolerant coliform bacteria and Escherichia coli by the membrane filtration method
Regulated area: Tests
SOP č. 30 (ČSN 75 7835)
138 Drinking, surface, ground water Determination of intestinal enterococci by the membrane filtration method
Regulated area: Tests
SOP č. 31 (ČSN EN ISO 7899-2)
139 Drinking, surface, ground water Determination of the microscopic picture, bioseston and abioseston
bioseston abioseston
Regulated area: Tests
SOP č. 32 (ČSN 75 7712; ČSN 75 7713)
140 Drinking water Determination of Escherichia coli and coliform bacteria by the membrane filtration method
Regulated area: Tests
SOP č. 35 (ČSN EN ISO 9308-1)
141 Drinking water Sampling of drinking water
Regulated area: Sampling
SOP č. 38 (ČSN EN ISO 5667-1; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 5667-3; ČSN EN ISO 19458; Vyhl. č. 252/2004 Sb.)
142 Surface water Sampling of surface water (manual sampling)
Regulated area: Sampling
SOP č. 53 (ČSN EN ISO 5667-1; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-3; ČSN EN ISO 19458)
143 Ground water Sampling of ground water (manual sampling)
Regulated area: Sampling
SOP č. 54 (ČSN EN ISO 5667-1; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 5667-3; ČSN EN ISO 19458)
144 Waste water Sampling of waste water (manual sampling and sampling with an automatic sampler)
Regulated area: Sampling
SOP č. 39 (ČSN EN ISO 5667-1; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN EN ISO 5667-3)
145 Sludges Sampling of sludges (manual sampling)
Regulated area: Sampling
SOP č. 55 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-14; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15)
P5 Moravská Třebová
146 Drinking, raw, waste, surface water Determination of pH by potentiometry
Regulated area: Tests
SOP 14/2015 (ČSN ISO 10523)
147 Drinking, raw, surface water Determination of electrical conductivity
Regulated area: Tests
SOP 15/2015 (ČSN EN 27888)
148 Drinking, raw, waste, surface water Determination of dissolved solids (DS) and dissolved inorganic salts (DIS) by gravimetry
dissolved solids (DS) dissolved inorganic salts (DIS)
Regulated area: Tests
SOP 09/2007 (ČSN 75 7346; ČSN 75 7347)
149 Drinking, raw, waste, surface water Determination of suspended solids (SS) by gravimetry
Regulated area: Tests
SOP 16/2015 (ČSN EN 872)
150 Drinking, raw, waste, surface water Determination of biochemical oxygen demand (BODn) with an optical sensor
Regulated area: Tests
SOP 17/2015 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN ISO 17289)
151 Drinking, raw, waste, surface water Determination of chemical oxygen demand by dichromate (CODCr) by spectrophotometry
Regulated area: Tests
SOP 12/2012 (ČSN ISO 15705)
152 Drinking, raw, waste, surface water Determination of ammonium ions by spectrophotometry and ammonium nitrogen by calculation
ammonium nitrogen (calculated)
Regulated area: Tests
SOP 18/2015 (ČSN ISO 7150-1)
153 Drinking, raw, waste, surface water Determination of phosphates and total phosphorus after mineralisation by spectrophotometry
phosphates total phosphorus
Regulated area: Tests
SOP 19/2015 (ČSN EN ISO 6878)
154 Drinking, raw, surface water Determination of iron by spectrophotometry
Regulated area: Tests
SOP 01/2001 (ČSN ISO 6332)
155 Drinking, raw, waste, surface water Determination of nitrites by spectrophotometry and nitrite nitrogen by calculation
nitrite nitrogen (calculated)
Regulated area: Tests
SOP 20/2015 (ČSN EN 26777)
156 Drinking, raw water Determination of acid neutralising capacity (ANC) by titration
Regulated area: Tests
SOP 21/2015 (ČSN EN ISO 9963-1)
157 Drinking, raw water Determination of the sum of calcium and magnesium by titration, magnesium by calculation
sum of calcium and magnesium
magnesium (calculated)
Regulated area: Tests
SOP 22/2015 (ČSN ISO 6059)
158 Drinking, raw water Determination of calcium by titration
Regulated area: Tests
SOP 23/2015 (ČSN ISO 6058)
159 Drinking, raw, waste water Determination of chlorides by titration
Regulated area: Tests
SOP 24/2015 (ČSN ISO 9297)
160 Drinking, raw water Determination of sulphates by titration
Regulated area: Tests
SOP 25/2015 (ČSN 75 7477)
161 Drinking, raw water Determination of chemical oxygen demand by permanganate (CODMn) by titration
Regulated area: Tests
SOP 06/2001 (ČSN EN ISO 8467)
162 Drinking, raw water Determination of manganese by spectrophotometry
Regulated area: Tests
SOP 05/2001 (ČSN 83 0520-21:1978)
163 Drinking, raw water Determination of absorbance at 254 nm by spectrophotometry
Regulated area: Tests
SOP 35/2019 (ČSN 75 7360)
164 Drinking, raw water Determination of colour by spectrophotometry
Regulated area: Tests
SOP 02/2001 (ČSN EN ISO 7887)
165 Drinking, raw, waste, surface water Determination of nitrates by spectrophotometry and nitrate and total inorganic nitrogen by calculation
nitrate nitrogen (calculated), total inorganic nitrogen (calculated)
Regulated area: Tests
SOP 26/2015 (ČSN ISO 7890-3)
166 Drinking, raw water Indicative sensory determination of odour
Regulated area: Tests
SOP 07/2005 (ČSN EN 1622; ČSN 75 7340)
167 Drinking water Indicative sensory determination of taste
Regulated area: Tests
SOP 08/2005 (ČSN EN 1622; ČSN 75 7340)
168 Drinking, raw, waste water Determination of temperature
Regulated area: Tests
SOP 27/2015 (ČSN 75 7342)
169 Drinking water Determination of free chlorine by photometry using a HACH kit
Regulated area: Tests
SOP 04/2005 (Manuál firmy HACH)
170 Sludges Determination of total solids and water content by gravimetry (dry matter)
total solids water content
Regulated area: Tests
SOP 28/2015 (ČSN EN 15934:2013)
171 Sludges Determination of loss on ignition by gravimetry
Regulated area: Tests
SOP 29/2015 (ČSN EN 15935)
172 Drinking, raw water Determination of turbidity by nephelometry
Regulated area: Tests
SOP 30/2015 (ČSN EN ISO 7027-1)
173 Drinking, raw, waste, surface water Determination of total nitrogen by spectrophotometry using a HACH kit
Regulated area: Tests
SOP 13/2012 (Manuál firmy HACH)
174 Drinking, raw, waste, surface water Determination of dissolved oxygen with an optical sensor probe
Regulated area: Tests
SOP 36/2019 (ČSN ISO 17289)
175 Drinking, raw, waste, surface water Determination of nitrates by spectrophotometry using a HACH kit and nitrate and total inorganic nitrogen by calculation
nitrate nitrogen (calculated), total inorganic nitrogen (calculated)
Regulated area: Tests
SOP 11/2011 (Manuál firmy HACH)
176 Drinking, raw water Determination of intestinal enterococci by the membrane filtration method
Regulated area: Tests
SOP 31/2015 (ČSN EN ISO 7899-2)
177 Drinking, raw water Enumeration of culturable micro-organisms – colony count by inoculation in a nutrient agar medium at 36 °C and 22 °C
at 36 °C at 22 °C
Regulated area: Tests
SOP 32/2015 (ČSN EN ISO 6222)
178 Drinking, raw water Determination of Escherichia coli and coliform bacteria by the membrane filtration method
Regulated area: Tests
SOP 33/2015 (ČSN EN ISO 9308-1)
179 Drinking, raw water Determination of thermotolerant coliform bacteria and Escherichia coli by the membrane filtration method
Regulated area: Tests
SOP 34/2018 (ČSN 75 7835)

Reference standards (205)

AHEM č. 1/2008
EPA 325.3:1982
EPA 375.4:1978
Janoušek I., Fiala J.: Vodní hospodářství 38B, 51:1988
Manuál firmy HACH
Manuál firmy Merck
SOP 01/2001
SOP 02/2001
SOP 04/2005
SOP 05/2001
SOP 06/2001
SOP 07/2005
SOP 08/2005
SOP 09/2007
SOP 10
SOP 101
SOP 102
SOP 11
SOP 11/2011
SOP 12
SOP 12/2012
SOP 13/2012
SOP 14/2015
SOP 15/2015
SOP 16/2015
SOP 17/2015
SOP 18/2015
SOP 19
SOP 19/2015
SOP 1A
SOP 1B
SOP 20/2015
SOP 21/2015
SOP 22/2015
SOP 23/2015
SOP 24
SOP 24/2015
SOP 25
SOP 25/2015
SOP 26/2015
SOP 27/2015
SOP 28/2015
SOP 29/2015
SOP 2B
SOP 2C
SOP 30/2015
SOP 31/2015
SOP 32/2015
SOP 33/2015
SOP 34/2018
SOP 35/2019
SOP 36/2019
SOP 3B
SOP 4
SOP 5
SOP 6
SOP 7
SOP 8
SOP 9
SOP č. 1
SOP č. 10
SOP č. 11
SOP č. 12
SOP č. 13
SOP č. 14
SOP č. 15
SOP č. 15A
SOP č. 16
SOP č. 17
SOP č. 17A
SOP č. 17B
SOP č. 18
SOP č. 19
SOP č. 2
SOP č. 20
SOP č. 201
SOP č. 202
SOP č. 203
SOP č. 204
SOP č. 207
SOP č. 209
SOP č. 21
SOP č. 210
SOP č. 212
SOP č. 213
SOP č. 22
SOP č. 23
SOP č. 24
SOP č. 25
SOP č. 26
SOP č. 27
SOP č. 28
SOP č. 29
SOP č. 3
SOP č. 30
SOP č. 30A
SOP č. 31
SOP č. 32
SOP č. 33
SOP č. 34
SOP č. 35
SOP č. 36
SOP č. 37
SOP č. 38
SOP č. 39
SOP č. 4
SOP č. 40
SOP č. 400
SOP č. 403
SOP č. 404
SOP č. 41
SOP č. 45
SOP č. 46
SOP č. 5
SOP č. 50
SOP č. 51
SOP č. 53
SOP č. 54
SOP č. 55
SOP č. 56
SOP č. 6
SOP č. 7
SOP č. 8
SOP č. 9
SOP č. B 1
SOP č. B 2
SOP č. B 4
TNI 75 7521
TNV 75 7431
Vyhl. č. 238/2011 Sb.
Vyhl. č. 252/2004 Sb.
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7350
ČSN 75 7360
ČSN 75 7367
ČSN 75 7372
ČSN 75 7373
ČSN 75 7455
ČSN 75 7477
ČSN 75 7536
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN 75 7837
ČSN 757372
ČSN 83 0520-21:1978
ČSN EN 12176:1999
ČSN EN 12880:2021
ČSN EN 13346:2001 metoda B
ČSN EN 15934:2013
ČSN EN 15935
ČSN EN 1622
ČSN EN 1899-2
ČSN EN 26 777
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN 903
ČSN EN ISO 11731
ČSN EN ISO 11905-1
ČSN EN ISO 16266
ČSN EN ISO 19458
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878
ČSN EN ISO 6888-1
ČSN EN ISO 7027-1
ČSN EN ISO 7393-2
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9308-2
ČSN EN ISO 9963-1
ČSN ISO 10 523
ČSN ISO 10048:1996
ČSN ISO 10359-1
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 11261
ČSN ISO 15705
ČSN ISO 17289
ČSN ISO 5664
ČSN ISO 5667-10
ČSN ISO 5667-11
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6060
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 9297
ČSN ISO 9390

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1146