🇨🇿 Státní ústav jaderné, chemické a biologické ochrany, v.v.i. PL
Environment
Státní ústav jaderné, chemické a biologické ochrany, v.v.i. is a laboratory accredited by ČIA under number 1127 (Milín, Czech Republic). Its accreditation scope covers 56 test methods in the following areas: Environment. Test objects include: Indoor and outdoor air, Film and textile materials, Air, Drinking, surface and ground water.
At a glance
- Accreditation number: ČIA 1127
- Methods in scope: 56
- Types of test objects: 36
- City: Milín, Czech Republic
- Valid until: 15-05-2030
- Accreditation number
- 1127
- Accreditation body
- ČIA
- Address
- Kamenná 71, 262 31 Milín
- City
- Milín, Czech Republic
- Division
- Laboratorium Centralne SÚJCHBO
- Valid until
- 15-05-2030
What this laboratory tests (36)
- Indoor and outdoor air — 6 methods
- Film and textile materials — 4 methods
- Air — 3 methods
- Drinking, surface and ground water — 3 methods
- Indoor and outdoor environment — 3 methods
- Persons — 3 methods
- Aqueous samples — 2 methods
- Microbial cultures — 2 methods
- Sorbents — 2 methods
- Worker exposure, air — 2 methods
- Air samples — 1 method
- Building materials, water, filters, fallout, sludge, fly ash, soils and biological material — 1 method
- Contaminated surfaces — 1 method
- Film materials — 1 method
- Filters with captured dust, drinking, surface and waste water — 1 method
- and 21 more
Laboratory sections (7)
- Laboratory for toxic compounds /LTL/ — 20 methods
- Laboratory of dosimetry and radioactivity monitoring /LDMR/ — 13 methods
- Laboratory for radon measurement /LMR/ — 7 methods
- Autonomous department for support of the Supervision Authority /SOPD/ — 6 methods
- Laboratory for monitoring of persons under extreme conditions /LSOEP/ — 5 methods
- Laboratory for chemical monitoring and protection /LCHMO/ — 3 methods
- Laboratory for biological monitoring and protection /LBMO/ — 2 methods
Laboratory locations
- Laboratorium monitorowania osób w warunkach ekstremalnych /LSOEP/ — Žežická 226
- Laboratorium monitoringu i ochrony chemicznej /LCHMO/ — tř. Kpt. Jaroše 5
- Laboratorium pomiarów radonu /LMR/ — Kamenná 71
- Laboratorium dozymetrii i monitoringu promieniotwórczości /LDMR/ — Kamenná 71
- Laboratorium monitoringu i ochrony biologicznej /LBMO/ — Kamenná 71
- Laboratorium substancji toksycznych /LTL/ — Kamenná 71
- Samodzielny dział wsparcia nadzoru /SOPD/ — Kamenná 71
Certificate information
- Certificate date
- 15.05.2025
Accreditation scope — test methods (56)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory for monitoring of persons under extreme conditions /LSOEP/ | |||||
| 1 | Indoor and outdoor environment | Measurement of microclimatic conditions Regulated area: Tests |
Interní metodika B1/MET/01 (ČSN EN ISO 7726) | ||
| 2 | Persons | Measurement of thermal load according to physiological measurements Regulated area: Tests |
Interní metodika B1/MET/02 (ČSN EN ISO 9886) | ||
| 3 | Persons | Measurement of thermal load according to subjective assessment scales Regulated area: Tests |
Interní metodika B1/MET/03 (ČSN EN ISO 10551) | ||
| 4 | Persons | Determination of energy expenditure Regulated area: Tests |
Interní metodika B1/MET/04 (ČSN EN ISO 8996) | ||
| 5 | Special clothing | Test of the effect on the user's thermal comfort during practical wear Regulated area: Tests |
Interní metodika B1/MET/06 (Nařízení vlády č. 361/2007) | ||
| Laboratory for chemical monitoring and protection /LCHMO/ | |||||
| 6 | Film and textile materials | Determination of the resistance of barrier materials to permeation of selected organic substances by GC-FID Regulated area: Tests |
MAZL 16-95/Permeatest 2 (ČSN EN 16523-1+A1; ČSN EN 16523-2+A1; ASTM F739-20) | ||
| 7 | Film and textile materials | Determination of the resistance of barrier materials to acids and basis by visual colour change of indicator Regulated area: Tests |
MAZL 04-95/Aciditest 1 (ČSN EN 16523-1+A1; ČSN EN 374-1) | ||
| 8 | Respiratory protective equipment | Measurement of the tightness of respiratory protective equipment against aerosols and dust particles by measuring the dispersion of light on condensed particles Regulated area: Tests |
MAZL 40-11/Portacount (ČSN EN 136; OSHA 29CFR1910) | ||
| Laboratory for radon measurement /LMR/ | |||||
| 9 | Raw, drinking and ground water | Measurement of radon activity concentration in water using ionization chambers Regulated area: Tests |
Interní metodika LMR-1 (Doporučení SÚJB DR-RO-5.1 /Rev.0.0) | ||
| 10 | Indoor and outdoor air, soil gas | Measurement of the instantaneous values of radon volume activity by scintillation Regulated area: Tests |
Interní metodika LMR-2 | ||
| 11 | Indoor and outdoor air | Measurement of the instantaneous values of radon equivalent volume activity by alpha spectrometry Regulated area: Tests |
Interní metodika LMR-3 | ||
| 12 | Indoor and outdoor air | Short-term measurements of radon activity concentration in buildings using alpha spectrometry Regulated area: Tests |
Interní metodika LMR-4 (Doporučení SÚJB DR-RO-5.0 /Rev.2.0) | ||
| 13 | Indoor and outdoor air | Short-term measurements of equilibrium-equivalent activity concentration in buildings Regulated area: Tests |
Interní metodika LMR-5 (Doporučení SÚJB DR-RO-5.0 /Rev.2.0) | ||
| 14 | Soil | Determination of subsoil permeability by measuring pneumatic resistance Regulated area: Tests |
Interní metodika LMR-6 (Doporučení SÚJB DR-RO-5.0 /Rev.2.2) | ||
| 15 | Indoor and outdoor environment | Measurement of dose rate (gamma radiation) Regulated area: Tests |
Interní metodika LMR-7 (Doporučení SÚJB DR-RO-5.0 /Rev.2.0) | ||
| Laboratory of dosimetry and radioactivity monitoring /LDMR/ | |||||
| 16 | Drinking, surface and ground water | Determination of total alpha activity concentration by measuring evaporated residue using a ZnS(Ag) scintillation detector Regulated area: Tests |
ČSN 75 7611 kap. 4 | ||
| 17 | Drinking, surface and ground water | Determination of total beta activity concentration by measuring evaporated residue using a proportional counter Regulated area: Tests |
ČSN 75 7612 | ||
| 18 | Air | Determination of activity concentration of long-lived alpha-emitting radionuclides using a proportional or semiconductor detector Regulated area: Tests |
Interní metodika M-1 | ||
| 19 | Monitored environment | Determination of photon dose equivalent rate using thermoluminescent dosimeters (TLDs) Regulated area: Tests |
Interní metodika M-4b | ||
| 20 | Worker exposure | Measurement of kerma using thermoluminescent dosimeters (TLDs) Regulated area: Tests |
Interní metodika M-4 | ||
| 21 | Building materials, water, filters, fallout, sludge, fly ash, soils and biological material | Non-destructive determination of the activity concentration of gamma-emitting radionuclides in the energy range of 46.5–1836 keV using high-resolution gamma spectrometry and calculation of the mass activity index (I) from the measured values Regulated area: Tests |
Interní metodika M-5 (ČSN ISO 10703; Doporučení SÚJB DR-RO-5.2 (Rev.0.0) – SÚJB/OS/18895/2017; Doporučení SÚJB DR-RO-5.3 (Rev.0.0) – SÚJB/OS/20299/2017) | ||
| 22 | Filters with captured dust, fillings from frit absorbers, drinking, surface and waste water | Fluorometric determination of uranium Regulated area: Tests |
Interní metodika M-13 | ||
| 23 | Filters with captured dust, drinking, surface and waste water | Determination of radium-226 after preconcentration by measuring separated Ba(Ra)SO4 in a mixture with ZnS(Ag) scintillator Regulated area: Tests |
Interní metodika M-14 (PNU 83 0501 - podniková norma ČSUP z roku 1978) | ||
| 24 | Air | Long-term integral measurement of radon activity concentration in air using a trace detector placed in a diffusion chamber Regulated area: Tests |
Interní metodika R-6 | ||
| 25 | Air | Long-term integral measurement of alpha-emitting radionuclide activity concentration in air using a trace detector Regulated area: Tests |
Interní metodika R-10 | ||
| 26 | Worker exposure, air | Determination of latent energy intake using the ALGADE personal dosimeter. Determination of average latent energy concentration using stationary ALGADE detectors Regulated area: Tests |
Interní metodika R-10b | ||
| 27 | Worker exposure, air | Determination of latent energy intake using a personal dosimeter with a trace detector Regulated area: Tests |
Interní metodika R-10c | ||
| 28 | Drinking, surface and ground water | Spectrophotometric determination of uranium after separation on macroporous silica gel Regulated area: Tests |
Interní metodika M-11 (ČSN 75 7614) | ||
| Laboratory for biological monitoring and protection /LBMO/ | |||||
| 29 | Microbial cultures | Identification of high-risk and risk biological agents by means of mass spectrometry Bacillus anthracis Mycobacterium tuberculosis Brucella melitensis Salmonella typhi Burkholderia mallei Shigella dysenteriae Burkholderia pseudomallei Vibrio cholerae Clostridium botulinum Yersinia pestis Francisella tularensis Yersinia pseudotuberculosis Legionella pneumophila Regulated area: Tests |
Interní metodika B-MALDI-01 | ||
| 30 | Microbial cultures | Identification of pathogenic bacterial species by nanopore whole-genome sequencing Regulated area: Tests |
Interní metodika B-SEQ-01 | ||
| Laboratory for toxic compounds /LTL/ | |||||
| 31 | Film materials | Determination of the resistance of barrier materials to permeation of sulphur mustard by gas chromatography Regulated area: Tests |
MAZL 39-10/Permeatest 4 (ČSN EN 16523-1+A1; ČSN EN 16523-2+A1) | ||
| 32 | Film and textile materials | Determination of the resistance time of protective materials to sulphur mustard under static conditions by indicator colour change Regulated area: Tests |
MAZL 03-95/Mikrotest, Minitest (ČSN EN 16523-1+A1; ČSN EN 16523-2+A1) | ||
| 33 | Film and textile materials | Determination of the protective properties of barrier materials against soman and sulphur mustard vapours and drops by indicator colour change Regulated area: Tests |
MAZL 36-10/Permeatest 3 (ČSN EN 16523-1+A1; ČSN EN 16523-2+A1) | ||
| 34 | Respiratory protective devices | Determination of the resistance of protective breathing equipment to the permeation of chemical agents by photoionization detection Regulated area: Tests |
MAZL 41-12/ SMARTMAN (BS 8468-1; BS 8468-2; BS 8468-8; ČSN EN 134; ČSN EN 136; ČSN EN 137; ČSN EN 13274-1) | ||
| 35 | Sorbents | Determination of the sorption capacity of sorbents used to catch organic chemical by photoionization detection Regulated area: Tests |
MAZL 19-95/DSK-Test 2 (ČSN EN 14387, kap. 5 a 6) | ||
| 36 | Sorbents | Determination of the sorption capacity of sorbents used to catch inorganic agents by electrochemical detectors Regulated area: Tests |
MAZL 20-95/DSK-Test 3 (ČSN EN 14387, kap. 5 a 6) | ||
| 37 | Protective clothing | Colorimetric determination of the tightness of chemical protective suits Regulated area: Tests |
MAZL 37-09/LUCIE | ||
| 38 | Liquid organic samples | Identification of CWC-Scheduled chemicals by GC-EI/MS O-Isopropyl methylphosphonofluoridate (GB; 1A01) O-Pinacolyl methylphosphonofluoridate (GD; 1A01) O-Cyclohexyl methylphosphonofluoridate (GF; 1A01) O-Ethyl N,N-dimethyl phosphoramidocyanidate (GA; 1A02) O-Ethyl S-2-diisopropylaminoethyl methyl phosphonothiolate (VX; 1A03) O-Isobutyl S-2-diethylaminoethyl methylphosphonothiolate (VR/RVX; 1A03) O-Butyl S-2-diethylaminoethyl methylphosphonothiolate (CVX; 1A03) 2-Chloroethylchloromethylsulfide (1A04) Bis(2-chloroethyl)sulfide (HD; 1A04) Bis(2-chloroethylthio)methane (1A04) 1,2-Bis(2-chloroethylthio)ethane (Q; 1A04) 1,3-Bis(2-chloroethylthio)-n-propane (1A04) 1,4-Bis(2-chloroethylthio)-n-butane (1A04) 1,5-Bis(2-chloroethylthio)-n-pentane (1A04) Bis(2-chloroethylthiomethyl)ether (1A04) Bis(2-chloroethylthioethyl)ether (T; 1A04) 2-Chlorovinyldichloroarsine (Lewisite 1/L1; 1A05) Bis(2-chlorovinyl)chloroarsine (Lewisite 2/L2; 1A05) Tris(2-chlorovinyl)arsine (Lewisite 3/L3; 1A05) Bis(2-chloroethyl)ethylamine (HN1; 1A06) Bis(2-chloroethyl)methylamine (HN2; 1A06) Tris(2-chloroethyl)amine (HN3; 1A06) Methylphosphonic difluoride (DF; 1B09) Ethylphosphonic difluoride (1B09) Propylphosphonic difluoride (1B09) Isopropylphosphonic difluoride (1B09) O-Ethyl O-2-diisopropylaminoethyl methylphosphonite (QL; 1B10) O-Isopropyl methylphosphonochloridate (1B11) O-Pinacolyl methylphosphonochloridate (1B12) Regulated area: Tests |
CH/2021/04-GCMS-CW | ||
| 39 | Gaseous samples / vapours | Identification of CWC-Scheduled chemicals by GC-EI/MS using microextraction techniques O-Isopropyl methylphosphonofluoridate (GB; 1A01) O-Pinacolyl methylphosphonofluoridate (GD; 1A01) O-Cyclohexyl methylphosphonofluoridate (GF; 1A01) O-Ethyl N,N-dimethyl phosphoramidocyanidate (GA; 1A02) O-Ethyl S-2-diisopropylaminoethyl methyl phosphonothiolate (VX; 1A03) O-Isobutyl S-2-diethylaminoethyl methylphosphonothiolate (VR/RVX; 1A03) O-Butyl S-2-diethylaminoethyl methylphosphonothiolate (CVX; 1A03) 2-Chloroethylchloromethylsulfide (1A04) Bis(2-chloroethyl)sulfide (HD; 1A04) Bis(2-chloroethylthio)methane (1A04) 1,2-Bis(2-chloroethylthio)ethane (Q; 1A04) 1,3-Bis(2-chloroethylthio)-n-propane (1A04) 1,4-Bis(2-chloroethylthio)-n-butane (1A04) 1,5-Bis(2-chloroethylthio)-n-pentane (1A04) Bis(2-chloroethylthiomethyl)ether (1A04) Bis(2-chloroethylthioethyl)ether (T; 1A04) 2-Chlorovinyldichloroarsine (Lewisite 1/L1; 1A05) Bis(2-chlorovinyl)chloroarsine (Lewisite 2/L2; 1A05) Tris(2-chlorovinyl)arsine (Lewisite 3/L3; 1A05) Bis(2-chloroethyl)ethylamine (HN1; 1A06) Bis(2-chloroethyl)methylamine (HN2; 1A06) Tris(2-chloroethyl)amine (HN3; 1A06) Methylphosphonic difluoride (DF; 1B09) Ethylphosphonic difluoride (1B09) Propylphosphonic difluoride (1B09) Isopropylphosphonic difluoride (1B09) O-Ethyl O-2-diisopropylaminoethyl methylphosphonite (QL; 1B10) O-Isopropyl methylphosphonochloridate (1B11) O-Pinacolyl methylphosphonochloridate (1B12) Regulated area: Tests |
CH/2021/06-GCMS-EXT, kap. 7.2 | ||
| 40 | Aqueous samples | Identification of CWC-Scheduled chemicals by GC-EI/MS using microextraction techniques O-Isopropyl methylphosphonofluoridate (GB; 1A01) O-Pinacolyl methylphosphonofluoridate (GD; 1A01) O-Cyclohexyl methylphosphonofluoridate (GF; 1A01) O-Ethyl N,N-dimethyl phosphoramidocyanidate (GA; 1A02) O-Ethyl S-2-diisopropylaminoethyl methyl phosphonothiolate (VX; 1A03) O-Isobutyl S-2-diethylaminoethyl methylphosphonothiolate (VR/RVX; 1A03) O-Butyl S-2-diethylaminoethyl methylphosphonothiolate (CVX; 1A03) 2-Chloroethylchloromethylsulfide (1A04) Bis(2-chloroethyl)sulfide (HD; 1A04) Bis(2-chloroethylthio)methane (1A04) 1,2-Bis(2-chloroethylthio)ethane (Q; 1A04) 1,3-Bis(2-chloroethylthio)-n-propane (1A04) 1,4-Bis(2-chloroethylthio)-n-butane (1A04) 1,5-Bis(2-chloroethylthio)-n-pentane (1A04) Bis(2-chloroethylthiomethyl)ether (1A04) Bis(2-chloroethylthioethyl)ether (T; 1A04) 2-Chlorovinyldichloroarsine (Lewisite 1/L1; 1A05) Bis(2-chlorovinyl)chloroarsine (Lewisite 2/L2; 1A05) Tris(2-chlorovinyl)arsine (Lewisite 3/L3; 1A05) Bis(2-chloroethyl)ethylamine (HN1; 1A06) Bis(2-chloroethyl)methylamine (HN2; 1A06) Tris(2-chloroethyl)amine (HN3; 1A06) Methylphosphonic difluoride (DF; 1B09) Ethylphosphonic difluoride (1B09) Propylphosphonic difluoride (1B09) Isopropylphosphonic difluoride (1B09) O-Ethyl O-2-diisopropylaminoethyl methylphosphonite (QL; 1B10) O-Isopropyl methylphosphonochloridate (1B11) O-Pinacolyl methylphosphonochloridate (1B12) Regulated area: Tests |
CH/2021/06-GCMS-EXT, kap. 7.3 | ||
| 41 | Solid samples | Identification of CWC-Scheduled chemicals by GC-EI/MS using microextraction techniques O-Isopropyl methylphosphonofluoridate (GB; 1A01) O-Pinacolyl methylphosphonofluoridate (GD; 1A01) O-Cyclohexyl methylphosphonofluoridate (GF; 1A01) O-Ethyl N,N-dimethyl phosphoramidocyanidate (GA; 1A02) O-Ethyl S-2-diisopropylaminoethyl methyl phosphonothiolate (VX; 1A03) O-Isobutyl S-2-diethylaminoethyl methylphosphonothiolate (VR/RVX; 1A03) O-Butyl S-2-diethylaminoethyl methylphosphonothiolate (CVX; 1A03) 2-Chloroethylchloromethylsulfide (1A04) Bis(2-chloroethyl)sulfide (HD; 1A04) Bis(2-chloroethylthio)methane (1A04) 1,2-Bis(2-chloroethylthio)ethane (Q; 1A04) 1,3-Bis(2-chloroethylthio)-n-propane (1A04) 1,4-Bis(2-chloroethylthio)-n-butane (1A04) 1,5-Bis(2-chloroethylthio)-n-pentane (1A04) Bis(2-chloroethylthiomethyl)ether (1A04) Bis(2-chloroethylthioethyl)ether (T; 1A04) 2-Chlorovinyldichloroarsine (Lewisite 1/L1; 1A05) Bis(2-chlorovinyl)chloroarsine (Lewisite 2/L2; 1A05) Tris(2-chlorovinyl)arsine (Lewisite 3/L3; 1A05) Bis(2-chloroethyl)ethylamine (HN1; 1A06) Bis(2-chloroethyl)methylamine (HN2; 1A06) Tris(2-chloroethyl)amine (HN3; 1A06) Methylphosphonic difluoride (DF; 1B09) Ethylphosphonic difluoride (1B09) Propylphosphonic difluoride (1B09) Isopropylphosphonic difluoride (1B09) O-Ethyl O-2-diisopropylaminoethyl methylphosphonite (QL; 1B10) O-Isopropyl methylphosphonochloridate (1B11) O-Pinacolyl methylphosphonochloridate (1B12) Regulated area: Tests |
CH/2021/06-GCMS-EXT, kap. 7.4 | ||
| 42 | Solid and liquid organic samples | Identification of CWC-Scheduled chemicals by GC-EI/MS O-Isopropyl methylphosphonofluoridate (GB; 1A01) O-Pinacolyl methylphosphonofluoridate (GD; 1A01) O-Cyclohexyl methylphosphonofluoridate (GF; 1A01) O-Ethyl N,N-dimethyl phosphoramidocyanidate (GA; 1A02) O-Ethyl S-2-diisopropylaminoethyl methyl phosphonothiolate (VX; 1A03) O-Isobutyl S-2-diethylaminoethyl methylphosphonothiolate (VR/RVX; 1A03) O-Butyl S-2-diethylaminoethyl methylphosphonothiolate (CVX; 1A03) 2-Chloroethylchloromethylsulfide (1A04) Bis(2-chloroethyl)sulfide (HD; 1A04) Bis(2-chloroethylthio)methane (1A04) 1,2-Bis(2-chloroethylthio)ethane (Q; 1A04) 1,3-Bis(2-chloroethylthio)-n-propane (1A04) 1,4-Bis(2-chloroethylthio)-n-butane (1A04) 1,5-Bis(2-chloroethylthio)-n-pentane (1A04) Bis(2-chloroethylthiomethyl)ether (1A04) Bis(2-chloroethylthioethyl)ether (T; 1A04) 2-Chlorovinyldichloroarsine (Lewisite 1/L1; 1A05) Bis(2-chlorovinyl)chloroarsine (Lewisite 2/L2; 1A05) Tris(2-chlorovinyl)arsine (Lewisite 3/L3; 1A05) Bis(2-chloroethyl)ethylamine (HN1; 1A06) Bis(2-chloroethyl)methylamine (HN2; 1A06) Tris(2-chloroethyl)amine (HN3; 1A06) Methylphosphonic difluoride (DF; 1B09) Ethylphosphonic difluoride (1B09) Propylphosphonic difluoride (1B09) Isopropylphosphonic difluoride (1B09) O-Ethyl O-2-diisopropylaminoethyl methylphosphonite (QL; 1B10) O-Isopropyl methylphosphonochloridate (1B11) O-Pinacolyl methylphosphonochloridate (1B12) Regulated area: Tests |
CH/2021/05-GCMS-WI, kap. 7.3.1 | ||
| 43 | Wipes and solid sorbents | Identification of CWC-Scheduled chemicals by GC-EI/MS O-Isopropyl methylphosphonofluoridate (GB; 1A01) O-Pinacolyl methylphosphonofluoridate (GD; 1A01) O-Cyclohexyl methylphosphonofluoridate (GF; 1A01) O-Ethyl N,N-dimethyl phosphoramidocyanidate (GA; 1A02) O-Ethyl S-2-diisopropylaminoethyl methyl phosphonothiolate (VX; 1A03) O-Isobutyl S-2-diethylaminoethyl methylphosphonothiolate (VR/RVX; 1A03) O-Butyl S-2-diethylaminoethyl methylphosphonothiolate (CVX; 1A03) 2-Chloroethylchloromethylsulfide (1A04) Bis(2-chloroethyl)sulfide (HD; 1A04) Bis(2-chloroethylthio)methane (1A04) 1,2-Bis(2-chloroethylthio)ethane (Q; 1A04) 1,3-Bis(2-chloroethylthio)-n-propane (1A04) 1,4-Bis(2-chloroethylthio)-n-butane (1A04) 1,5-Bis(2-chloroethylthio)-n-pentane (1A04) Bis(2-chloroethylthiomethyl)ether (1A04) Bis(2-chloroethylthioethyl)ether (T; 1A04) 2-Chlorovinyldichloroarsine (Lewisite 1/L1; 1A05) Bis(2-chlorovinyl)chloroarsine (Lewisite 2/L2; 1A05) Tris(2-chlorovinyl)arsine (Lewisite 3/L3; 1A05) Bis(2-chloroethyl)ethylamine (HN1; 1A06) Bis(2-chloroethyl)methylamine (HN2; 1A06) Tris(2-chloroethyl)amine (HN3; 1A06) Methylphosphonic difluoride (DF; 1B09) Ethylphosphonic difluoride (1B09) Propylphosphonic difluoride (1B09) Isopropylphosphonic difluoride (1B09) O-Ethyl O-2-diisopropylaminoethyl methylphosphonite (QL; 1B10) O-Isopropyl methylphosphonochloridate (1B11) O-Pinacolyl methylphosphonochloridate (1B12) Regulated area: Tests |
CH/2021/05-GCMS-WI, kap. 7.3.2 | ||
| 44 | Aqueous samples | Identification of CWC-Scheduled chemicals by GC-EI/MS O-Isopropyl methylphosphonofluoridate (GB; 1A01) O-Pinacolyl methylphosphonofluoridate (GD; 1A01) O-Cyclohexyl methylphosphonofluoridate (GF; 1A01) O-Ethyl N,N-dimethyl phosphoramidocyanidate (GA; 1A02) O-Ethyl S-2-diisopropylaminoethyl methyl phosphonothiolate (VX; 1A03) O-Isobutyl S-2-diethylaminoethyl methylphosphonothiolate (VR/RVX; 1A03) O-Butyl S-2-diethylaminoethyl methylphosphonothiolate (CVX; 1A03) 2-Chloroethylchloromethylsulfide (1A04) Bis(2-chloroethyl)sulfide (HD; 1A04) Bis(2-chloroethylthio)methane (1A04) 1,2-Bis(2-chloroethylthio)ethane (Q; 1A04) 1,3-Bis(2-chloroethylthio)-n-propane (1A04) 1,4-Bis(2-chloroethylthio)-n-butane (1A04) 1,5-Bis(2-chloroethylthio)-n-pentane (1A04) Bis(2-chloroethylthiomethyl)ether (1A04) Bis(2-chloroethylthioethyl)ether (T; 1A04) 2-Chlorovinyldichloroarsine (Lewisite 1/L1; 1A05) Bis(2-chlorovinyl)chloroarsine (Lewisite 2/L2; 1A05) Tris(2-chlorovinyl)arsine (Lewisite 3/L3; 1A05) Bis(2-chloroethyl)ethylamine (HN1; 1A06) Bis(2-chloroethyl)methylamine (HN2; 1A06) Tris(2-chloroethyl)amine (HN3; 1A06) Methylphosphonic difluoride (DF; 1B09) Ethylphosphonic difluoride (1B09) Propylphosphonic difluoride (1B09) Isopropylphosphonic difluoride (1B09) O-Ethyl O-2-diisopropylaminoethyl methylphosphonite (QL; 1B10) O-Isopropyl methylphosphonochloridate (1B11) O-Pinacolyl methylphosphonochloridate (1B12) Regulated area: Tests |
CH/2021/05-GCMS-WI, kap. 7.3.3 | ||
| 45 | Soil samples | Identification of CWC-Scheduled chemicals by GC-EI/MS O-Isopropyl methylphosphonofluoridate (GB; 1A01) O-Pinacolyl methylphosphonofluoridate (GD; 1A01) O-Cyclohexyl methylphosphonofluoridate (GF; 1A01) O-Ethyl N,N-dimethyl phosphoramidocyanidate (GA; 1A02) O-Ethyl S-2-diisopropylaminoethyl methyl phosphonothiolate (VX; 1A03) O-Isobutyl S-2-diethylaminoethyl methylphosphonothiolate (VR/RVX; 1A03) O-Butyl S-2-diethylaminoethyl methylphosphonothiolate (CVX; 1A03) 2-Chloroethylchloromethylsulfide (1A04) Bis(2-chloroethyl)sulfide (HD; 1A04) Bis(2-chloroethylthio)methane (1A04) 1,2-Bis(2-chloroethylthio)ethane (Q; 1A04) 1,3-Bis(2-chloroethylthio)-n-propane (1A04) 1,4-Bis(2-chloroethylthio)-n-butane (1A04) 1,5-Bis(2-chloroethylthio)-n-pentane (1A04) Bis(2-chloroethylthiomethyl)ether (1A04) Bis(2-chloroethylthioethyl)ether (T; 1A04) 2-Chlorovinyldichloroarsine (Lewisite 1/L1; 1A05) Bis(2-chlorovinyl)chloroarsine (Lewisite 2/L2; 1A05) Tris(2-chlorovinyl)arsine (Lewisite 3/L3; 1A05) Bis(2-chloroethyl)ethylamine (HN1; 1A06) Bis(2-chloroethyl)methylamine (HN2; 1A06) Tris(2-chloroethyl)amine (HN3; 1A06) Methylphosphonic difluoride (DF; 1B09) Ethylphosphonic difluoride (1B09) Propylphosphonic difluoride (1B09) Isopropylphosphonic difluoride (1B09) O-Ethyl O-2-diisopropylaminoethyl methylphosphonite (QL; 1B10) O-Isopropyl methylphosphonochloridate (1B11) O-Pinacolyl methylphosphonochloridate (1B12) Regulated area: Tests |
CH/2021/05-GCMS-WI, kap. 7.3.4 | ||
| 46 | Gaseous samples, solid and liquid samples | Identification of CWC-Scheduled chemicals by GC-EI/MS using thermal desorption O-Isopropyl methylphosphonofluoridate (GB; 1A01) O-Pinacolyl methylphosphonofluoridate (GD; 1A01) O-Cyclohexyl methylphosphonofluoridate (GF; 1A01) O-Ethyl N,N-dimethyl phosphoramidocyanidate (GA; 1A02) O-Ethyl S-2-diisopropylaminoethyl methyl phosphonothiolate (VX; 1A03) O-Isobutyl S-2-diethylaminoethyl methylphosphonothiolate (VR/RVX; 1A03) O-Butyl S-2-diethylaminoethyl methylphosphonothiolate (CVX; 1A03) 2-Chloroethylchloromethylsulfide (1A04) Bis(2-chloroethyl)sulfide (HD; 1A04) Bis(2-chloroethylthio)methane (1A04) 1,2-Bis(2-chloroethylthio)ethane (Q; 1A04) 1,3-Bis(2-chloroethylthio)-n-propane (1A04) 1,4-Bis(2-chloroethylthio)-n-butane (1A04) 1,5-Bis(2-chloroethylthio)-n-pentane (1A04) Bis(2-chloroethylthiomethyl)ether (1A04) Bis(2-chloroethylthioethyl)ether (T; 1A04) 2-Chlorovinyldichloroarsine (Lewisite 1/L1; 1A05) Bis(2-chlorovinyl)chloroarsine (Lewisite 2/L2; 1A05) Tris(2-chlorovinyl)arsine (Lewisite 3/L3; 1A05) Bis(2-chloroethyl)ethylamine (HN1; 1A06) Bis(2-chloroethyl)methylamine (HN2; 1A06) Tris(2-chloroethyl)amine (HN3; 1A06) Methylphosphonic difluoride (DF; 1B09) Ethylphosphonic difluoride (1B09) Propylphosphonic difluoride (1B09) Isopropylphosphonic difluoride (1B09) O-Ethyl O-2-diisopropylaminoethyl methylphosphonite (QL; 1B10) O-Isopropyl methylphosphonochloridate (1B11) O-Pinacolyl methylphosphonochloridate (1B12) Regulated area: Tests |
CH/2021/07-GCMS-TD | ||
| 47 | Wipes | Taking of wipe samples for subsequent instrumental qualitative analysis (manual sampling) Regulated area: Sampling |
CH/2014/01-SAMP-1 (OPCW, Quality system document No.QDOC/LAB/WI/SC005) | ||
| 48 | Liquids | Taking of liquid samples for subsequent instrumental qualitative analysis (manual sampling, automatic sampler) Regulated area: Sampling |
CH/2014/02-SAMP-2 (OPCW, Quality system document No.QDOC/LAB/WI/SC004) | ||
| 49 | Solid materials | Taking of solid samples for subsequent instrumental qualitative analysis (manual sampling) Regulated area: Sampling |
CH/2014/03-SAMP-3 (OPCW, Quality system document No.QDOC/LAB/WI/SC003) | ||
| 50 | Air samples | Taking of air samples for further instrumental qualitative analysis (manual sampling, automatic sampling pump) Regulated area: Sampling |
CH/2014/04-SAMP-4 (OPCW, Quality system document No.QDOC/LAB/WI/SC002; OPCW, Quality system document No.QDOC/LAB/SOP/OSA1) | ||
| Autonomous department for support of the Supervision Authority /SOPD/ | |||||
| 51 | Contaminated surfaces | Measurement of the surface contamination by alpha-emitting radioactive substances (as,alpha) Regulated area: Tests |
Interní metodika SOPD/01 (PNU 83 0101) | ||
| 52 | Indoor and outdoor air | Continuous measurement of radon activity concentration (OAR) Regulated area: Tests |
Interní metodika SOPD/02 (Doporučení SÚJB DR-RO-5.0 (Rev.2.0) - SÚJB/OS/4904/2018) | ||
| 53 | Indoor and outdoor air | Determination of the volume activity of long-lived alpha-emitting radionuclides (av,alpha) Regulated area: Tests |
Interní metodika SOPD/03 (Doporučení SÚJB DR-RO-5.0 (Rev.2.0) - SÚJB/OS/4904/2018) | ||
| 54 | Indoor and outdoor air | Determination of the latent energy concentration of radon decay products (KLE) Regulated area: Tests |
Interní metodika SOPD/04 (Doporučení SÚJB DR-RO-5.0 (Rev.2.0) - SÚJB/OS/4904/2018) | ||
| 55 | Indoor and outdoor environment | Measurement of photon dose equivalent, dose rate of external gamma radiation (Hx,Dgamma) Regulated area: Tests |
Interní metodika SOPD/05 (Doporučení SÚJB DR-RO-5.2 (Rev.0.0) - SÚJB/OS/3914/2018) (Doporučení SÚJB DR-RO-5.3 (Rev.0.0) SÚJB/OS/20299/2017) | ||
| 56 | Outdoor and indoor air | Measurement of radon equivalent volume activity (EOAR) Regulated area: Tests |
Interní metodika SOPD/06 (Doporučení SÚJB DR-RO-5.0 (Rev.2.0) - SÚJB/OS/4904/2018) | ||
Reference standards (86)
ASTM F739-20
BS 8468-1
BS 8468-2
BS 8468-8
CH/2014/01-SAMP-1
CH/2014/02-SAMP-2
CH/2014/03-SAMP-3
CH/2014/04-SAMP-4
CH/2021/04-GCMS-CW
CH/2021/05-GCMS-WI
CH/2021/06-GCMS-EXT
CH/2021/07-GCMS-TD
Doporučení SÚJB DR-RO-5.0 (Rev.2.0) - SÚJB/OS/4904/2018
Doporučení SÚJB DR-RO-5.0 /Rev.2.0
Doporučení SÚJB DR-RO-5.0 /Rev.2.2
Doporučení SÚJB DR-RO-5.1 /Rev.0.0
Doporučení SÚJB DR-RO-5.2 (Rev.0.0) - SÚJB/OS/3914/2018
Doporučení SÚJB DR-RO-5.2 (Rev.0.0) – SÚJB/OS/18895/2017
Doporučení SÚJB DR-RO-5.3 (Rev.0.0) SÚJB/OS/20299/2017
Doporučení SÚJB DR-RO-5.3 (Rev.0.0) – SÚJB/OS/20299/2017
Interní metodika B-MALDI-01
Interní metodika B-SEQ-01
Interní metodika B1/MET/01
Interní metodika B1/MET/02
Interní metodika B1/MET/03
Interní metodika B1/MET/04
Interní metodika B1/MET/06
Interní metodika LMR-1
Interní metodika LMR-2
Interní metodika LMR-3
Interní metodika LMR-4
Interní metodika LMR-5
Interní metodika LMR-6
Interní metodika LMR-7
Interní metodika M-1
Interní metodika M-11
Interní metodika M-13
Interní metodika M-14
Interní metodika M-4
Interní metodika M-4b
Interní metodika M-5
Interní metodika R-10
Interní metodika R-10b
Interní metodika R-10c
Interní metodika R-6
Interní metodika SOPD/01
Interní metodika SOPD/02
Interní metodika SOPD/03
Interní metodika SOPD/04
Interní metodika SOPD/05
Interní metodika SOPD/06
MAZL 03-95/Mikrotest, Minitest
MAZL 04-95/Aciditest 1
MAZL 16-95/Permeatest 2
MAZL 19-95/DSK-Test 2
MAZL 20-95/DSK-Test 3
MAZL 36-10/Permeatest 3
MAZL 37-09/LUCIE
MAZL 39-10/Permeatest 4
MAZL 40-11/Portacount
MAZL 41-12/ SMARTMAN
Nařízení vlády č. 361/2007
OPCW, Quality system document No.QDOC/LAB/SOP/OSA1
OPCW, Quality system document No.QDOC/LAB/WI/SC002
OPCW, Quality system document No.QDOC/LAB/WI/SC003
OPCW, Quality system document No.QDOC/LAB/WI/SC004
OPCW, Quality system document No.QDOC/LAB/WI/SC005
OSHA 29CFR1910
PNU 83 0101
PNU 83 0501 - podniková norma ČSUP z roku 1978
ČSN 75 7611 kap. 4
ČSN 75 7612
ČSN 75 7614
ČSN EN 13274-1
ČSN EN 134
ČSN EN 136
ČSN EN 137
ČSN EN 14387, kap. 5 a 6
ČSN EN 16523-1+A1
ČSN EN 16523-2+A1
ČSN EN 374-1
ČSN EN ISO 10551
ČSN EN ISO 7726
ČSN EN ISO 8996
ČSN EN ISO 9886
ČSN ISO 10703